SUBJECT: PUD 00-112/PIP87-02(A) - ATRIUM II
Thank you for applying for Land Use Permits in the City of Carlsbad. The Planning
Department has reviewed your Nonresidential Planned Unit Development and Planned
Industrial Permit Amendment, application no. PUD 00-112 and PIP 87-02(A), as to its
completeness for processing.
All of the items requested of you earlier have not been received and therefore your
application is still deemed incomplete. Listed below are the item(s) still needed in order to
deem your application as complete. This list of items must be submitted directly to your
staff planner by appointment. All list items must be submitted simultaneously and a copy
of this list must be included with your submittals. No processing of your application can
occur until the application is determined to be complete. When all required materials are
submitted the City has 30 days to make a determination of completeness. If the
application is determined to be complete, processing for a decision on the application will
be initiated. In addition, please note that you have six months from the date the
application was initially filed, October 17, 2000, to either resubmit the application or
submit the required information. Failure to resubmit the application or to submit the
materials necessary to determine your application complete shall be deemed to constitute
withdrawal of the application. If an application is withdrawn or deemed withdrawn, a new
application must be submitted.
Please contact your staff planner, Paul Godwin, at (760) 602-4625, if you have any
questions or wish to set up a meeting to discuss the application.
Sincerely,
MICHAEL J. HOLZMILLER
Planning Director
MJH:PG:mh
c: Chris DeCerbo
Jeremy Riddle
File Copy
Data Entry
Planning Aide
1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us
LIST OF ITEMS NEEDED
TO COMPLETE THE APPLICATION
No. PUD 00-112/PIP 87-02(A)
Planning:
None.
Engineering:
1. On the site plan identify the projected average daily traffic (ADT) for the proposed
project utilizing latest SANDAG figures.
2. Provide a Soils Report addressing the feasibility and recommendations associated
with the proposed project. Identify if there is anticipated remedial grading required
for the project.
ISSUES OF CONCERN
Planning:
None.
Engineering:
1. On the site plan and conceptual grading plan include the proposed driveway slope
as it approaches Loker Avenue. Refer to redline set of plans for guidance.
2. On the site plan and conceptual grading plan add symbols to clarify hardscape
between the rolled curb and the existing access-hole. The hardscape could consist
of PCC, grasscrete or asphalt.
3. One the conceptual landscape plan, call out the size and type of the existing public
sewer main and call out all existing access-holes. Also add call outs to ensure that
deep-rooted landscaping will not be installed over the existing public sewer main.
Also depict the line-of-sight at the driveway entrance looking onto Loker Avenue
using Caltrans Standards. The conceptual landscape plan was not included with
this second review to verify if these previous issues were addressed.
4. On the conceptual grading plan, indicate how a truck (per Caltrans 407-E) with a
42-foot turning radius will circulate throughout the site. Depict the inside and
outside turning radius of the truck at all critical turns to demonstrate feasibility.
This is required to demonstrate feasibility of trash trucks and fire trucks traversing
the site.
5. Address redlines as noted on the returned site plan and conceptual grading plan.
6. Attached is a redlined print of the project with engineering staff comments. Please
be advised, this check print must me returned with the revised plans to facilitate
continued staff review.
City of Carlsbad
Planning Department
November 15, 2000
Newport National Corporation
2117 Industrial Court Suite E
Vista, CA 92083
SUBJECT: PUD 00-112/PIP87-02(A) - ATRIUM II
Thank you for applying for Land Use Permits in the City of Carlsbad. The Planning Department
has reviewed your Nonresidential Planned Unit Development and Planned Industrial Permit
Amendment, application no. PUD 00-112 and PIP87-02(A), as to its completeness for
processing.
The application is incomplete, as submitted. Attached are two lists. The first list is information
which must be submitted to complete your application. This list of items must be submitted
directly to your staff planner by appointment. All list items must be submitted
simultaneously and a copy of this list must be included with your submittals. No
processing of your application can occur until the application is determined to be complete. The
second list is issues of concern to staff. When all required materials are submitted the City has
30 days to make a determination of completeness. If the application is determined to be
complete, processing for a decision on the application will be initiated. In addition, please note
that you have six months from the date the application was initially filed, October 16, 2000, to
either resubmit the application or submit the required information. Failure to resubmit the
application or to submit the materials necessary to determine your application complete shall be
deemed to constitute withdrawal of the application. If an application is withdrawn or deemed
withdrawn, a new application must be submitted.
Please contact your staff planner, Paul Godwin, at (760) 602-4625, if you have any questions or
wish to set up a meeting to discuss the application.
Sincerely,
\/\b4w^
MICHAELJ>HOLZ1VIILLER
Planning Director
MJH:PG:cs
Chris DeCerbo
Jeremy Riddle
File Copy
Data Entry
Planning Aide
1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-4600 • FAX (760) 602-8559 • www.ci.carlsbad.ca.us
LIST OF ITEMS NEEDED
TO COMPLETE THE APPLICATION
No. PUD 00-112/PIP 87-02(A)
Planning:
None.
Engineering:
1. On the site plan identify the projected average daily traffic (ADT) for the proposed project
utilizing latest SANDAG figures.
2. On the site plan include the distance from the project driveway to the southerly
intersection with Palomar Airport Road.
3. On the site plan and conceptual grading plan, identify the record document that secures
the reciprocal access easements for the shared driveway entrance with the adjacent
property. Provide a copy for our records.
4. On the site plan provide sufficient dimensions on the site plan to clearly identify the size
of parking stalls and drive aisle widths.
5. On the site plan and conceptual grading plan depict and call-out all existing underground
facilities along the project frontage of Loker Avenue (size, type, hydraulic grade line,
reference drawings, etc.)
6. Provide a Soils Report addressing the feasibility and recommendations associated with
the proposed project. Identify if there is anticipated remedial grading required for the
project.
7. Provide a title report for the subject property.
8. Provide a hydrology study that addresses storm flows experienced by the site and what
measures are required in order to intercept the flows. Identify measures to ensure that
post-development storm flows do not exceed pre-development storm flows.
9. Revise the site plan to depict all proposed easements. The current one only shows
existing easements.
10. Revise the site plan to show the existing and proposed facilities required to serve the
project.
ISSUES OF CONCERN
Planning:
1. Please include employee eating area calculations on plans.
2. Please show proposed roof screening plan.
Engineering:
1. The updated National Pollution Discharge Elimination System (NPDES) permit is
nearing approval, and would involve significant changes to this project and other projects
processed throughout the San Diego region. It is our understanding that these changes
would not include a grandfather clause for projects. This means that this project and all
other projects will be immediately impacted pursuant to the approved NPDES
requirements, no matter what stage projects are in. We encourage you to review the
draft permit requirements so that you understand the nature of our comments when they
are made on projects. In order to facilitate compliance of this project, the following are
some criteria that should be incorporated into the design of the project:
a) Post development run-off should not exceed pre-development run-off. This shall
be certified via engineering calculations in the project hydrology/hydraulic report.
Revise the plans to show all provisions to ensure no increase storm flows via
methods such as detainment areas, ponded parking lots, detention basins, etc.
b) On parking lot areas, include additional measures required to capture anticipated
pollutants from the site. More often than not, grass-lined swales should be
utilized to filter storm water before entering inlets. Fossil-filters alone may not be
sufficient to capture all pollutants.
c) Offsite and downstream siltation would not be permitted at any time during the
project (long term or near term).
2. On the site plan and conceptual grading plan depict the preliminary location of
irrigation and fire sprinkler service connections required to serve the project. Revise
the legend to include all necessary symbols and call-outs.
3. Revise the conceptual grading plan and the site plan to include minimum 24-foot
drive aisles. A 21.5 foot aisle is un acceptable.
4. Coordinate all elements of the project between the site plan and the conceptual
grading plan. Missing items will lead to discrepancies in the project design (trash
enclosures, water meter construction, etc.).
5. Consider having the site plan contain all the project information versus having a
conceptual grading plan and a site plan. This may ease coordination and eliminate
having duplicate information between the two drawings.
6. On the conceptual grading plan revise the topographic numbers so they are legible.
7. Revise the conceptual grading plan to identify how the northerly sump area drains.
Identify the system that conveys storm water from this area.
8. Revise the site plan and conceptual grading plan to depict the location of the onsite
storm drain system to ensure there are no conflicts with the project design.
9. On the site plan and conceptual grading plan clarify the granting of two types of
easements. One should be a public waterline easement granted to the Carlsbad
Municipal Water District. The other will be a access easement granted to the City of
Carlsbad.
10. On the site plan and conceptual grading plan include the proposed driveway slope
on the plans.
11. On the site plan and conceptual grading plan identify the paved width of the existing
driveway.
12. On the site plan and conceptual grading plan provide vehicular access to the existing
sewer access-hole as shown on the returned plan. City crews must be able to
maneuver a vactor truck to the access-hole in order to perform maintenance or
repairs as needed to this public facility.
13. On the site plan and conceptual grading plan locate and callout the proposed potable
water and irrigation water meter close to each other for ease of meter-reader access.
14. On the site plan and conceptual grading plan ensure that all meter boxes are located
within the proposed public water easement. This includes meters that are relocated
as part of the project.
15. On the site plan, conceptual grading plan, and conceptual landscape plan add
callouts to ensure that deep-rooted landscaping will not be installed over the existing
public sewer main.
16. On the site plan, conceptual grading plan, and conceptual landscape plan callout the
size and type of the existing public sewer main and callout all existing access-holes.
17. On the conceptual grading plan identify the location of the trash enclosure to serve
Lotl
18. On the conceptual grading plan, indicate how a truck (per Caltrans 407-E) with a 42-
foot turning radius will circulate throughout the site. Depict the inside and outside
turning radius of the truck at all critical turns to demonstrate feasibility.
19. On the site plan, conceptual grading plan, and conceptual landscape plan depict the
line-of-sight at the driveway entrance looking onto Loker Avenue using Caltrans
Standards.
20. On the site plan and conceptual grading plan, depict the double detector check valve
assembly of the fire service for the site (per CMWD standards). Ensure the double
detector check valve is not located within public water easements, since are the
responsibility of the owner.
21. On the site plan and conceptual grading plan, identify all measures required to ensure
that post-development run-off does not exceed pre-development run-off.
22. Revise the project hydrology study to comply with the above item.
23. Address redlines as noted on the returned site plan, conceptual grading plan, and
conceptual landscape plan.
24. Attached is a redlined check print of the project with Engineering staff comments.
Please be advised, this check print must be returned with the revised plans to
facilitate continued staff review.
City of Carlsbad
Planning Department
August 8, 2000
Mr. Scott Brusseau
Newport National Corporation
2117 Industrial Court, Suite C
Vista, CA 92083
SUBJECT: PRE 00-50 - LOT 2 CARLSBAD OAKS BUSINESS PARK
APN: 204-081-02-00
A preliminary review of your project was conducted on July 27, 2000. Listed below are the
issues raised by staff. Please note that the purpose of a preliminary review is to provide you
with direction and comments on the overall concept of your project. The preliminary review
does not represent an in-depth analysis of your project. Additional issues of concern
may be raised after your application is submitted and processed for a more specific and
detailed review.
Planning:
1. The subject site is located in the Planned Industrial (P-M) zone and in the Carlsbad
Airport Center Specific Plan (SP 200). The General Plan Land Use designation is
Planned Industrial (PI). The proposed project will be subject to all development
standards, policies and provisions contained in these documents. Copies of these
documents are available at the Development Services Planning Front Counter.
2. The overall request to develop a three-story office building on a site which presently
contains an existing three-story office building is generally supported by staff. The use is
allowed in the P-M zone and by the Carlsbad Airport Specific Plan, and all building
setbacks have been met.
3. It will be necessary to amend the existing Planned Industrial Permit (PIP 87-02) for this
site. The current fee for a Planned Industrial Permit Amendment is $1,250 and
applications are available at the Development Services Planning Front Counter.
4. No building heights have been proposed. Building heights may not exceed 35', with a
maximum of three stories. Height protrusions which do not exceed 45' and do not
provide usable floor area may be allowed, pursuant to Sections 21.34.070(1) and
21.46.020 of the City of Carlsbad Municipal Code. Additional building height to a
maximum of 45' may be approved by the Planning Director with increased setbacks at a
ratio of one horizontal foot for every one foot of vertical construction beyond 35'.
5. Parking areas shall be planted with trees at the ratio of one tree per each five parking
stalls. Parking islands shall be designed in conformance with the City of Carlsbad
Landscape Manual. Parking stalls and aisle widths shall comply with the design
standards outlined in Chapter 21.44 of the Carlsbad Municipal Code.
1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-46OO • FAX (760) 602-8559
PRE 00-50 - LOT 2 C/H.SBAD OAKS BUSINESS CENTER
August 8, 2000
Page 2
6. All mechanical/roof equipment shall be completely screened from view in a manner
which is architecturally compatible with the overall building design.
7. Employee eating areas shall be provided at the rate of 300 square feet per 5,000 square
feet of building area. Amenities shall be provided within the outdoor eating area, as
described in Chapter 21.30.070 of the Carlsbad Municipal Code.
8. A minimum of 15% of the building site shall be landscaped. Please comply with the
requirements of the Carlsbad Airport Center Specific Plan and -the City of Carlsbad
Landscape Manual.
Engineering:
9. Please be advised that in order to make a more in-depth review of the proposed
development, a more complete design of the project is required.
10. The proposed quitclaim of the existing sewer easement may only be considered if an
access easement is granted to the City of Carlsbad in order to access the existing rear-
lot facilities. See the plans for a preliminary layout of the access easement.
11. Identify if there are grade changes over the existing sewer and water mains.
12. Add symbols to the plans to identify the difference between existing and proposed
improvements.
13. Depict the location of existing adjacent buildings and surface improvements.
14. Please indicate all existing and proposed utilities along Loker Avenue (i.e., storm drain,
water, sewer, etc.) that will serve the development. Indicate gravity flow sewer facilities
with invert elevations. The submitted plan does not depict any facilities, except sewer.
15. Depict all existing sewer and water facilities (onsite) and all their appurtenances (access
holes, valves, fire hydrants, blow-offs, air-release valves) to identify if there conflicts with
existing and proposed improvements.
16. Indicate all existing and proposed surface improvements (curb, gutter, sidewalk, paving,
inlets, street lights, adjacent driveways, vaults, transformers, etc.) along property fronting
Loker Avenue, and verify that no conflicts exist.
17. Identify the distance from the driveway to Palomar Airport Road.
18. Revise the plan to indicate the ADT (traffic), EDU's (sewer), GPM (potable water), and
GPM (reclaimed water) generated or required by the proposed development.
19. Identify the anticipated ADT at the shared driveway serving Lot 1 and Lot 2. Clarify
whether this will be a medium-use or high-use driveway.
20. Meet with the Fire Department to identify the necessary fire protection measures
required for this project (access, fire hydrants, sprinklering, etc.). All proposed fire
hydrants must be served by public water mains.
PRE 00-50 - LOT 2 JK-SBAD OAKS BUSINESS CENTER
August 8, 2000
Page 3
21. Show all existing and proposed topography and drainage patterns for the site. Revise
the plans to indicate how on-site surface runoff is controlled. Identify the location,
alignment, and discharge of any proposed drainage system.
22. Indicate the legal description of the proposed development. Indicate legal descriptions
of all adjacent properties.
23. Provide a Vicinity Map on the site plan.
24. Submit the site plan at either a 1" = 40', or, 1" = 20' scale.
25. Indicate the volume of grading (cut, fill, import, export, remedial) proposed for the project
in cubic yards. There is insufficient information provided to make a clear determination
of whether a grading permit is required.
26. A Public Improvement will be required for modifications to existing facilities in order to
avoid conflicts between existing and proposed facilities.
27. If slopes are proposed off-site, a private slope easement must be obtained from the
adjacent property owner.
28. Delete any proposed parking spaces that are directly adjacent to a proposed drive aisle
to avoid potential conflicts with vehicles backing out.
29. Provide a parking lot connection/outlet so that parking lot aisle lengths do not exceed
150-feet.
30. Show typical street sections of Loker Avenue that indicate existing and proposed
improvements.
31. Dimension the site plan. Drive aisles must have a minimum width of 24'. Unless they
are adjacent to a parallel loading area, then the drive aisle must have a minimum width
of 32'.
32. Depict the location of trash enclosures required to serve the development. Call-out
enclosures per Carlsbad Standard drawing GS-16. Identify how refuse trucks will
maneuver throughout the site.
33. A recent Preliminary Title Report (PR) (issued within 6 months of formal application
submittal) will be required for the proposed project.
34. All easements and encumbrances as identified in Schedule "B" of the PR must be
indicated on the site plan. The future disposition of any easements and encumbrances
must also be identified.
35. The complete property boundary must be shown on the site plan, which must include all
bearings and distances.
36. Please indicate how a truck (per Caltrans 407-E) with a 42-foot turning radius will
circulate throughout the site.
PRE 00-50 - LOT 2
August 8, 2000
Page 4
cM_SBAD OAKS BUSINESS CENTER
37. Indicate how National Pollutant Discharge Elimination System (NPDES) criteria will be
met. This could include, but not be limited to, doing one or a combination of the
following: directing surface run-off through vegetated swales prior to discharge to a
storm drain or the public right of way, constructing a gravel/sand/fossil filter system,
constructing de-pollutant basins, etc. Also, any loading areas that are located in a sump
must have pump facilities to direct drainage to a pollutant mitigation area.
38. Clarify whether a joint-use access easement has been secured for the southerly
driveway (see original PIP conditions of approval). If not one should be obtained as part
this application.
39. Indicate the line-of-sight at the driveway entrance looking north and south onto Loker
Avenue using Caltrans guidelines. Verify no conflicts exist.
40. Provide a preliminary hydrology study that identifies the development discharge flows.
The study should also identify preliminary recommendations on the anticipated storm
drain infrastructure required as part of the development.
41. This preliminary review does not constitute a complete review of the proposed project,
additional items of concern may be identified upon formal project application submittal.
42. A redlined check print is enclosed for the applicants use in making the requested
revisions. This check print should be returned with the formal application
submittal to facilitate continued staff review.
Please contact Paul Godwin at (760) 602-4625 if you have any questions.