Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutRP 03-02; Ureta 2nd Dwelling Unit; Redevelopment Permits (RP) (2)June 28, 2005
City ofCarlsbad
Housing & Redevelopment Department
2965 Roosevelt Street Suite B
Carlsbad, CA 92008-2389
Attention Mr. Cliff Jones
Re: Ureta Single Family Residence (RP03-02 ) Letter Dated June 23, 2005
Dear Cliff,
As you well know from reviewing my file, I have tried from several different angles to
re-develop my property located at 3280 Roosevelt Street. Unfortimately, I feel that
placing a fifteen (15) foot wide home, (outside measurement) on a twenty five (25) foot
wide lot is just too narrow a structure to live in comfortably. Even a fifteen and one half
(15.5) foot home is too narrow but would proceed with a modular home if the City of
Carlsbad would allow it.
To date, I have invested over $7000.00 and lots of time, hope and energy in trying to
move forward with the redevelopment of my property. As you stated in our telephone
conversation yesterday, the City of Carlsbad is not going to provide me with a variance to
reduce the side setback from five (5) feet. Therefore, at this time I reluctantly, will not be
proceeding with processing my application. Perhaps, I may attempt to redevelop this
property at a future date.
Cliff, pursuant to our telephone conversation yesterday, please refimd my application fee
to me. Please make check out to Joel Ureta and mail to 3280 Roosevelt Street.
Should you have any ideas in the future on how to develop this narrow lot, I am open to
suggestions.
Thank you for your time and efforts pertaining to this matter.
Cordially,
Joel Ureta
760 535 6240
Citv of Carlsbad
Housing & Redevelopment Department
June 23, 2005
HAROLD CURRY
PLANNING-DESIGN
3197 JAMES DRIVE
CARLSBAD, CA 92008
SUBJECT: URETA SINGLE FAMILY RESIDENCE (RP03-02)
The above referenced application has been on file for well over two years (February 26,
2003 to June 23, 2005). Notification was given on March 2, 2005 that the application
was complete, along with a list of issues of concern that needed to be addressed in
order to complete the review of the proposed project (attached). To date, our office has
not received any correspondence addressing the issues.
A decision will be needed within the next thirty (30) days to determine if you wish to
proceed with the processing of the application. If you wish to proceed, please provide
the information requested in the attached letter that was previously sent to you on
March 2, 2005. Failure to resubmit the necessary plans addressing the issues by July
23, 2005, shall be deemed to constitute withdrawal of the application. If an application
is withdrawn or deemed withdrawn, a new application must be submitted.
Please contact my office at (760) 434-2813 if you have any questions and/or wish to
apply for a refund of any unused fees.
Sincerely,
Cliff Jones
Assistant Planner
Joel Ureta, Owner
Attachment
2965 Roosevelt St., Ste. B • Carlsbad, CA 92008-2389 • (760) 434-2810/2811 • FAX (760) 720-2037
Itv of Carlsbad
Housing & Redevelopment Department
March 2, 2005
HAROLD CURRY
PLANNING - DESIGN
3197 JAMES DRIVE
CARLSBAD, CA 92008
Re: Ureta Single Family Residence - 3280 Roosevelt Street (RP 03-02)
The purpose of this letter is to provide a written response, as you have recently requested in
your letter dated Febraury 21, 2005, to the letter that you sent to our office on January 25,
2005. After receiving your letter dated January 25, 2005 I decided to call you on the phone
instead of sending a written response detailing the same issues of concern as the letter
previously sent. In our phone discussion on January 28, 2005, I explained to you that staff
could support a variance for the garage to encroach into the side yard setback, since garages
are required to be a minimum of 20'x20' and the strict application of the code requiring a 20'
wide garage and 5' side yard setbacks would deprive the subject property, which is 25 feet
wide, of having a garage. I then further explained to you that the residence, however, would not
be able to encroach into the side yard setback simply because the applicant wished to have a
larger residence. I explained to you that staff was not convinced that the strict application of
the zone regulation (VR, District 5) requiring ali new development to have a 5' side yard setback
deprives the property of privileges enjoyed by other properties which developed under the same
zone regulation. I explained that all new development would be required to have the minimum
5' side yard setbacks. Towards the end of our phone discussion on January 28, 2005, you
informed me that you would speak with the property owner to see if he/she wished to proceed
with the application and propose a residence that meets the required setbacks or wished to
withdraw the application. Between January 29, 2005 and up until your letter dated February 21,
2005, staff did not have any correspondence with you, the applicant, or the property owner and
assumed that you were discussing staff's issues of concern with the property owner.
As you have requested, attached to this letter are the issues of concern raised by various City
Departments following a review of your letter dated January 25, 2005 for the above-mentioned
project application. These issues must be addressed prior to staff making a formal
recommendation on the project.
Please contact my office at (760) 434-2813, if you have any questions or wish to set up a
meeting to discuss the application.
Sincerely,
CUFF JONES
Assistant Planner
Attachments
c: Joanne Juchniewicz, Engineering 2965 Roosevelt St., Ste. B • Carlsbad, OA 92008-2389 • (760) 434-2810/2811 • FAX (760) 720-2037 ^
ISSUES OF CONCERN
No. RP03-02
The following items need to be resolved or adequately addressed prior to staff formulating a
recommendation on the proposed project: (Please note, the issues are listed under the
department which identified them as an area of concern.)
HOUSING & REDEVELOPMENT:
1. As mentioned previously, a variance is required to reduce the side yard setbacks to less
than five (5) feet and staff is required to have sufficient evidence to warrant issuance of
a variance. In particular staff and the City Attorney must be convinced that because of
special circumstances applicable to the subject property, including size, the strict
application of the zone regulation deprives such property of privileges enjoyed by other
property in the vicinity and under identical zoning classification (please refer to the
variance findings attached).
Since the municipal code requires for garages to be a minimum size of 20' x 20' staff is
able to support a variance for the garage since strict application of the 5' setback in this
case would result in a garage that is less than 20' wide and would deprive the property
owner of a garage that is safe for use. However staff cannot support the side yard
building setback at less than 5' simply because the applicant wishes to have a larger
manufactured home on site. It is the burden of the applicant to demonstrate why the
house cannot be built at the required 5' setbacks. Staff at this time is not convinced that
the strict application of the zone regulation (VR, District 5) requiring all new development
to have a 5' side yard setback deprives the property of privileges enjoyed by other
properties which developed under the same zone regulation. Please provide a written
letter with justification to grant the requested variance.
2. As mentioned previously, staff requests a sample of what the proposed manufactured
home looks like. Staff is unable to make a determination that the proposed
manufactured home meets the standards set forth under the Village Design Guidelines
with the black and white drafted plans provided. Staff requests a color sample of the
proposed manufactured home before a recommendation for approval can be made.
For questions regarding Housing & Redevelopment Department comments, please contact Cliff
Jones at 760-434-2813.
ENGINEERING:
1. Items a&b mentioned in previous correspondence have still not been adequately
addressed. The plans indicate that there is a 3 foot fall from the rear of the property to
the front of the property which is incorrect. A field investigation conducted on Dec. 29,
2004, after the heavy rains, revealed a pond of standing water at the rear of the property
by the ally. The investigation also revealed the front of the property by Roosevelt Street
is completely flat. As such, this lot, as it currently stands, does not drain properly. The
applicant must thoroughly and adequately address this issue before Engineering wili
approve this development. It appears that a soils engineer Is need for overall site
drainage as well as the proposed building being placed only 3' from property line.
2. On the site plan, please include the following information: (Note: These issues were
raised in our last correspondence.)
a. Show existing and proposed topography/spot elevations within and adjacent to
the site. This item is critical because the lot is very flat and Engineering will need
to assure that the lot drains appropriately.
b. Show drainage patterns (existing and proposed) on the site. (A soils engineer
recommendation/approval is required for the buildings to be located 3 feet from
property line instead of the required 5 feet).
If you have any questions regarding engineering issues, please contact Joanne Juchniewicz in
the Engineering Department at 760-602-2775.
m FEB 28 P 12^ OU HAROLD CURRY
Carlsbad, CA. 92008
760/729-8933
February 21, 2005
CityofCarlsbad
Housing and Redevelopment Department
2965 Roosevelt St. Suite B
Carlsbad, CA. 92008-2389
Att: CliffJones
Re: Ureta Single Family Residence-3280 Roosevelt (RP-03-02)
On January 25, 2005, a detailed response to your Issues of Concem of January 11, 2005 was
submitted to you. No response has been received as of this date.
Kindly inform us in writing as to the complete status of Application, RP - 03 - 02, relative to
all of your requirements.
Thanking you in advance,
Harold Curry
cc: File/1
RECEIVEO
HAROLD CURRY JAN 2 8 2005
Planning/Design
3197 James Dr. t.«..ii!DfP££?R^5BAD
Carlsbad, CA. 92008 ^"^TlS^^^^
760/729-8933
January 25, 2005
CityofCarlsbad
Housing and Redevelopment Department
2965 Roosevelt St., Suite B
Carisbad, CA. 92008-2389
Att: CliffJones
Re: Ureta Single Family Residence- 3280 Roosevelt St. (RP- 03-02)
RESPONSES TO ISSUES OF CONCERN DATED JANUARY 11,2005
HOUSING & REDEVELOPMENT
1. Special circumstances are obviously applicable to the subject property begiiming
with the fact that with only a 25' width, it is impossible to conform with 5' side yard
set backs and attempt to follow design guidelines at the same time. For instance,
if 5' side yard is attempted, (only 4-6" available on other side ) the side walls of
proposed residence would, by necessity, have to be straight from fi^ont to back.
This is in conflict with your guide lines wherein broken lines are preferable for
more pleasing appearance and therein is the reason that the proposed design has
offset side lines from floor to roof. Which is more acceptable?? Side yards or
straight building lines.
On the title sheet of the originally submitted Plans, on the lower left side, all of
properties adjacent to the subject property and on the entire block of Roosevelt
St. are listed and shown to be non - conforming as to set backs. These facts
are directly related to the subject property being deprived of privileges ofthe
entire block. ( similar non-conformance to zoning regulations is further existing
in the area surrounding the block referred to)
The requested variance will not create a grant of special privileges inconsistant
with the side yards of the entire adjacent block of properties as each and every
adjacent property exists with non-conforming side yards ranging from less than
5* to zero lot line location of structures.
The existing residence on the subject property has zero side yards, being built
on the property side lines. It is again obvious that the proposed new residence
would create a substantial improvement with proposed side yards.
It appears further that the proposed variance is not in conflict with the intentions
of Sec. 21.35.130 (a), (b), (c), & (d) as well as the fact that variances are
permitted when special circumstances exist.
Relative to the garage width, it was originally designed to conform with a 21*
width. This can be reduced to 20' width with a 5' side yard on the north side.
The garage size is not related to the building size, nor is the size of the proposed
manufactured home arbitrarily preferred by the applicant. The standard size of
the chosen manufactured home is the only one available with a 15'-6" width.
None are available with a width less than 15-6".
Any deviation will increase costs and defeat applicant's intentions of creating a
family affordable home.
The impossibility of adherring to both side yards of 5' and following your design
guidelines is repeated while incorporating affordable and available manufactured
housing on the subject property being only 25' wide. Further, it is abundantly clear
that any attempt to construct a new stmcture in the deteriating subject neighborhood
would be an improvement over the existing established non-conforming stmctures.
2. You were previously given enlarged copies of the Engineered Plans available from
the manufacturer, Silvercrest. The only previous request relative to any colored plan
set forth a time for submittal following notification of a scheduled hearing date,
which
has not yet occurred.
It is difficult to imderstand the need for colored plans when none have ever been
made
required over the preceding years in relative plaiming involvements with Cities from
Los Angeles to San Diego and even the Califomia Coasta Commision. All previous
approvals and actual constmction involvement of more than 2,500 residences further
were never subject to more than normal drafting and printing of plans.
Therefore, a more precise discription of your colored requirements is asked for at this
time.
ENGINEERING
1. The statement that the original ground elevations are incorrect is insulting. Following
the
initial elevations revealing more than a 2% grade difference, further investigation
was not
pursued since the fact being that 2% has been a standard accepted for years. In this
case,
not only is the 2% difference existing front to back, but also side to side.
In spite of the foregoing, further elevations were recorded with reliable transit
instrumentation
and the results are shown herewith on site and each adjoining side.
As a matter of standard practice, it was originally anticipated that a slight swale
would be
constmcted as shown wherein 2% is noted on the site Plan. The minimal grading can
notbe
accomplished until demolition and constmction.
It must be noted also that there was not any noted nor reported damages from the
recent
excessive rains in the neighhood.
A fonnal investigation by a soils Engineer cannot expand upon known facts at this
time.
The appropriate time would follow existing demolition.
2. The spot elevations submitted herewith will be placed upon the Site Plan.
The (hrainage pattems are previously addressed.
Again, any soils reports and recommendations are not complete until actual footings
are excavated
with approval for foundation constmction.
It appears that a meeting may be necessary at this time following your review of the
preceding. Kindly
advise of suitable time and place.
Harold Curry
cc: file 1/
P.S. Kindly excuse any computer mistakes. A new computer with an apparent mind of its
own does not
wish to conform to commands.
0
0
0-
I
m
VJ
111
O
A
>
g
y
J
Ul
J
UJ
>
o
0
0
Citv of Carlsbad
Housing & Redevelopment Department
January 11, 200^5
HAROLD CURRY
PLANNING - DESIGN
3197 JAMES DRIVE
CARLSBAD, CA 92008
Re: Ureta Single Family Residence - 3280 Roosevelt Street (RP 03-02)
The purpose of this letter is to address issues of concern raised by various City Departments
following a review of the revised plans and revised above-mentioned project application. The
issues of concern are attached for your review. These issues must be addressed prior to staff
making a formal recommendation on the project.
Please contact my office at (760) 434-2813, if you have any questions or wish to set up a
meeting to discuss the application.
Sincerely,
CLIFF JONES
Assistant Planner
Attachments
c: Joanne Juchniewicz, Engineering
2965 Roosevelt St., Ste. B • Carlsbad, CA 92008-2389 • (760) 434-2810/2811 • FAX (760) 720-2037 ^
ISSUES OF CONCERN
No. RP03-02
Staff has completed a review of the subject project for issues of concern. The following items
need to be resolved or adequately addressed prior to staff formulating a recommendation on
the proposed project: (Please note, the issues are listed under the department which identified
them as an area of concern.)
HOUSING & REDEVELOPMENT:
1. As mentioned previously, a variance is required to reduce the side yard setbacks to less
than five (5) feet and staff is required to have sufficient evidence to warrant issuance of
a variance. In particular staff and the City Attorney must be convinced that because of
special circumstances applicable to the subject property, including size, the strict
application of the zone regulation deprives such property of privileges enjoyed by other
property in the vicinity and under identical zoning classification (please refer to the
variance findings attached).
Since the municipal code requires for garages to be a minimum size of 20' x 20' staff is
able to support a variance for the garage since strict application of the 5' setback in this
case would result in a garage that is less than 20' wide and would deprive the property
owner of a garage that is safe for use. However staff cannot support the side yard
building setback at less than 5' simply because the applicant wishes to have a larger
manufactured home on site. It is the burden of the applicant to demonstrate why the
house cannot be built at the required 5' setbacks. Staff at this time is not convinced that
the strict application of the zone regulation (VR, District 5) requiring all new development
to have a 5' side yard setback deprives the property of privileges enjoyed by other
properties which developed under the same zone regulation. Please provide a written
letter with justification to grant the requested variance.
2. As mentioned previously, staff requests a sample of what the proposed manufactured
home looks like. Staff is unable to make a determination that the proposed
manufactured home meets the standards set forth under the Village Design Guidelines
with the black and white drafted plans provided. Staff requests a color sample of the
proposed manufactured home before a recommendation for approval can be made.
For questions regarding Housing & Redevelopment Department comments, please contact Cliff
Jones at 760-434-2813.
ENGINEERING:
1. Items a&b mentioned in previous correspondence have still not been adequately
addressed. The plans indicate that there is a 3 foot fall from the rear of the property to
the front of the property which is incorrect. A field investigation conducted on Dec. 29,
2004, after the heavy rains, revealed a pond of standing water at the rear of the property
by the ally. The investigation also revealed the front of the property by Roosevelt Street
is completely flat. As such, this lot, as it currently stands, does not drain properly. The
applicant must thoroughly and adequately address this issue before Engineering will
approve this development. It appears that a soils engineer is need for overall site
drainage as well as the proposed building being placed only 3' from property line.
2. On the site plan, please include the following information: (Note: These issues were
raised in our last correspondence.)
a. Show existing and proposed topography/spot elevations within and adjacent to
the site. This item is critical because the lot is very flat and Engineering will need
to assure that the lot drains appropriately.
b. Show drainage patterns (existing and proposed) on the site. (A soils engineer
recommendation/approval is required for the buildings to be located 3 feet from
property line instead of the required 5 feet).
If you have any questions regarding engineering issues, please contact Joanne Juchniewicz in
the Engineering Department at 760-602-2775.
21.35.117
2U5.117 Notice of public hearings.
Notice of any public hearing required by this chap-
ter shall be given as provided in Section 21.54.060(1)
ofthis code. (Ord. NS-330 § 4 (part), 1995)
2U5.120 Consolidation of other pennits and
discretionaiy approvals—^Findings
requirements.
(a) Whenever a project would require a pennit
or approval und^the provisions of this title, notwith-
standing this chapter, the redevelopment pennit shall
be deemed to satisfy the requirements for such permh
or approvai; provided, however, that in considering
the redevelopment pennit for said project Ae direc-
tor, design review board and the housing and rede-
velopment commission shall apply the provisions of
this chapter and the provisions ofthis title otherwise
applicable to such other permit or approval for the
project
(b) Whenever a project consists only of exemp-
tion detenninations and/or administrative pennits or
administrative variances widiin the authority of either
the director of planning or the director, they shall be
consolidated and considered by*the director, subject
to appeal to the design review board widi regard to
determinations other than exemptions.
(c) Ifthe project includes permits or other dis-
cretionary approvals outside the director's adminis-
trative permit or administrative variance audiority,
the administrative permit and/or administrative vari-
ance aspects shall be consolidated with the other mat-
ters and submitted to the design review board.
(d) No variance, detennination of exemption or
administrative, minor or major redevelopment permit
shall be granted unless the decisionmaker finds, in
addition to any other findings otherwise required for
tbe project, that the project as approved, or condi-
tionally approved is consistent with this code, the
general plan, the Carisbad village area redevelopment
plan and the village master plan and design manual.
(Ord. NS-330 § 4 (part), 1995)
21J5.130 Variances.
(a) The housing and redevelopment commission
may grant variances fh>m the limits, restrictions and
controls established by this chapter for major rede-
velopment permits if the commission fmds that:
(1) Because of special circumstances applici^ie
to the subject property, including size, shape, topog-
raphy, location or surroundings, the strict application
of the zone regulation deprives such property of
privileges enjoyed by other property in the vicmity
and under identica] zoning ciassification;
(2) The variance shall not constitute a grant of
special privileges inconsistent with the limitations
upon other properties in the vicinity and zone iii
which the subject property is located and is subject to
any conditions necessary to assure compliance with
this finding;
(3) The variance does not audiorize a use or activ-
ity which is not otherwise expressly audiorized by the
zone regulation governing the subject property;
(4) The variance is consistent with die generai
purpose and intent of the general plan, Carlsbad vil-
lage area redevelopment plan, and the Carlsbad vil-
lage redevelopment master plan and design manual;
(5) In addition, in the coastal zone, diat the vari-
ance is consistent with and unplements the requue-
ments of the certified local coastal program and that
the variance does not reduce or in any manner ad-
versely affect the protection of coastal resources as
specified in the zones included in this tide, and that
the variance implements the purposes of zones
adopted to implement the local coastal program land
use plan.
(b) An application for a variance shall be proc-
essed in the same manner established by this chapter
for a redevelopment p^mit.
(c) The design review board may grant variances
from the limits, restrictions and controls established
by this chapter for minor redevelopment projects (or
otherwise administrative projects consoUdated or on
appeal from a director decision), if the board makes
the variance findings set forth in subsection (a) of
this section.
(d) The director may grant administrative vari-
ances in accordance with Section 2135.090(e), if the
directcH* makes the findings set forth in subsection (a)
of diis section. (Ord. NS-675 § 36, 2003: Ord. NS-
330 § 4 (part), 1995)
(CarlslMd Supp. No. 7.2-04) 648
t
RECEiVED
Harold Curry
Planning/Design^OQU DEC 11 P 3- U3
3197 James Dr.
Carlsbad, CA. 92008 V
760/729-893^''-^'^
CityofCarlsbad
Housing and Redevelopment Department
2965 Roosevelt St, Suite B
Carlsbad, CA. 92008-2389
December 15, 2004
Re: RP 03-02 Ureta Single Family Residence
3280 Rooseveh St.
Att.: CliffJones
Kindly find responses to your Issues of Concem as follows:
Housing & Redevelopment
Item #1, a thm f. Addressed on Plan Revisions attached
Item #1, g. On original Title sheet attached
Item#2, Addressed on Plan sheet #4
Item #3, The existing subject property is only twenty five feet wide which creates
an impossible architectural design to attempt to follow existing guidelines
The proposed Residence, as designed using manufactured housing, has
staggered wall lines and rooflines in an attempt to create a more pleasing
architectural appearance, while following your guidelines as closely as
possible.
It is felt that the proposed application conforms with all items concemed
with acceptance as allowed under Sec. 21.35.130 Variances.
Item#4, Addressed on Preliminary Landscape Plan attached.
Item#5, Addressed on original Plan and Engineered Sample attached.
Item#6, Sample of Federal Approved Engineered Plan attached. It is noted at this
time that another manufactured home by Silvercrest was previously
approved by Carlsbad and recently completed at 442 Chestnut located two
blocks from the proposed residence herein.
Item#7, The design guidelines have been followed since the outset of this
application within the extreme limitations present and the previous
preceding acceptance and approval noted together within the econom-
ical limits related.
ENGINNEERING
Item#l, Spot elevations were shown on the original Plot Plan on both ends of
the lot. Also drainage pattems were also shown following the 3 ft. +
slope from alley to front sidewalk. A Soils Engineer's recommendations
are assumed to be submitted when required for permit.
BUILDING
Item#l, The proposed manufactured residence is shown with Federal Approval as
stamped upon the sample Plan attached. Again, you have recently
approved of a manufactured residence completed by Silvercrest.
Item#2, Parapet wall has been added to the Garage Plan attached.
Respectfully su.
Harold Curry
CC: ffile/1
HAROLD CURRY
PLANNING/DESIGN R F C E1V F D
3197 James Dr.
Carlsbad, CA. 92008 mm, in A ii-hO
760/729-8933 '° ^
CiTY C- C/-.riS3AD liOUSIKG A!iD REDEVELOPME;
DEl^ARTMEHT December 8,2004
City of Carlsbad
Housing and Redevelopment
2965 Rooseveh St. Suite B
Carlsbad, CA. 92008
RE: RP 03-0002
Att.: CliffJones
Kindly find attached the executed sheets which you requested relative to the revised
Application. Other items of concem are in process of completion.
Respectfully
.-^^
Harold Curry
CC; Jureta/file 1
Citv of Carlsbad
Housing & Redevelopment Department
December 3, 2004
HAROLD CURRY
PLANNING - DESIGN
3197 JAMES DRIVE
CARLSBAD, CA 92008
Re: Ureta Single Family Residence - 3280 Roosevelt Street (RP 03-02)
The purpose of this letter is to address issues of concern raised by various City Departments
following a review of the revised plans and revised above-mentioned project application. The
issues of concern are attached for your review. These issues must be addressed prior to staff
making a formal recommendation on the project.
Please contact my office at (760) 434-2813, if you have any questions or wish to set up a
meeting to discuss the application.
Sincerely,
CLIFF JONES
Assistant Planner
Attachments
Joanne Juchniewicz, Engineering
Pat Kelley, Building
2965 Roosevelt St., Ste. B • Carlsbad, CA 92008-2389 • (760) 434-2810/2811 • FAX (760) 720-2037
ISSUES OF CONCERN
No. RP03-02
Staff has completed a review of the subject project for issues of concern. The following items
need to be resolved or adequately addressed prior to staff formulating a recommendation on
the proposed project: (Please note, the issues are listed under the department which identified
them as an area of concern.)
HOUSING & REDEVELOPMENT:
1. Please add the following information to the site plan:
a. Identify the General Plan land use designation as "V".
b. Identify the Zoning designation as "VR".
c. Identify the Land Use District as "5".
d. Identify the Project Density as "12.44 du/ac".
e. Provide a north arrow on site plan Identify Roosevelt Street on site plan.
f. Identify the percentage of open space. Area that qualifies as open space includes;
landscaped planters, open space pockets, balconies, and patios. No parking spaces
or drive aisles are permitted in the open space.
g. Show all adjacent uses.
1. Please include the directional language (north, south, east, west) on the building
elevations identified as front, rear, left, and right elevations.
2. A variance is required to reduce the side yard setbacks to less than five (5) feet. The
required findings have been attached. Please provide written justification to grant the
requested variance.
3. Provide a preliminary landscape plan for the site with the following information:
a. Typical plant species, quantity of each species and their size.
b. Percent of site used for landscaping.
1. Proposed development must be constructed on a permanent foundation (i.e. concrete
slab). Please modify plans accordingly.
2. Please provide a sample of what the proposed manufactured home looks like. Note that
the proposed manufactured home must meet the standards set forth under the Village
Design Guidelines in order for staft to make a recommendation for approval.
3. As part of the design review process, the Design Review Board must be satisfied that
the applicant has made an honest effort to conform to each of the ten basic principles
outlined in the Village Design Guidelines. Staft recommends that more attention be
given to principle No. 7 stating, "Buildings shall be enriched with architectural features
and details". A copy of the Village Design Guidelines has been enclosed for your use.
The ten basic design principles can be found on page 115 and additional suggestions
for architectural treatment of residential structures can be found on pages 133-136.
FUTURE ITEMS REQUIRED PRIOR TO HEARING DATE
As soon as all issues are resolved to the satisfaction of all Departments the project will be
scheduled for a Design Review Board hearing. To help expedite the processing of the permit
application the following information is being provided. The following items will be required for
the hearing:
A. Updated Public Notification Package: (Needed 3 weeks prior to hearing date.)
The public notification package shall include the following information:
a. A typewritten list of the names and addresses of all property owners within a 600'
radius of subject property (including the applicant and/or owner). The list shall
include the San Diego County Assessor's parcel number from the latest
assessment rolls.
b. 600' Radius Map: A map to scale not less than 1" = 200' showing each lot within
600' of the exterior boundaries of the subject property. Each of these lots shall
be consecutively numbered and correspond with the property owners list.
c. Two (2) separate sets of mailing labels of the property owners within a 600'
radius of the subject property. The list must be typed in all CAPITAL LETTERS,
left justified, void of punctuation. For any address other than single-family
residence, an apartment, suite or building number must be included on a
separate line. DO NOT include it in the street address line. DO NOT TYPE
ASSESSOR'S PARCEL NUMBER ON LABELS. DO NOT provide addressed
envelopes - PROVIDE LABELS ONLY.
UNACCEPTABLE UNACCEPTABLE ACCEPTABLE
Mrs. Jane Smith Mrs. Jane Smith MRS JANE SMITH
123 Magnolia Ave., Apt #3 123 Magnolia Ave. APT 3
Carlsbad, CA 92008 Apt. #3 123 MAGNOLIA AVE
Carlsbad, CA 92008 CARLSBAD CA 92008
B. One (1) copy of a full-sized (24" x 36") colored site plan. (Needed 2 weeks prior to
hearing date.)
C. One (1) copy of full-sized (24" x 36") colored building elevations accurately depicting
the proposed mature landscaping and how it relates to the building. (Needed 2
weeks prior to hearing date.)
D. Ten (10) sets of full size plans folded to 872" x 11". (Needed 2 weeks prior to hearing
date.)
E. One (1) set of QVz" x 11" black and white reduced plans. (Needed 2 weeks prior to
hearing date.)
F. Electronic files (in jpeg format) of the colored site plan and all building elevations
presented on disk or sent via e-mail to ciones@ci.carlsbad.ca.us (Needed 2 weeks
prior to hearing date.)
G. Please submit an 872" x 11 construction material board and color samples showing
roofing, exterior walls, trim, etc.
For questions regarding Housing & Redevelopment Department comments, please contact Clift
Jones at 760-434-2813.
ENGINEERING:
Staft has conducted a review of the project for engineering issues of concern. The following
engineering issues must be resolved or adequately addressed prior to staft making a
determination on the proposed project: (Note: These issues were raised in our last
correspondence, but were not included in the revised plans.)
1. On the site plan, please include the following information:
a. Show existing and proposed topography/spot elevations within and adjacent to
the site. This item is critical because the lot is very flat and Engineering will need
to assure that the lot drains appropriately.
b. Show drainage patterns (existing and proposed) on the site. (A soils engineer
recommendation/approval is required for the buildings to be located 3 feet from
property line instead of the required 5 feet).
If you have any questions regarding engineering issues, please contact Joanne Juchniewicz in
the Engineering Department at 760-602-2775.
BUILDING:
Staft has conducted a review of the project for building issues of concern. The following
building issues must be resolved or adequately addressed prior to staft making a determination
on the proposed project:
1. The proposed manufactured home must be listed for use as a residential unit by the
State of California.
2. The wall of the garage next to the property line has to be a rated wall and will require a
parapet.
For questions regarding Housing & Redevelopment Department comments, please contact Pat
Kelley at 760-602-2716.
10/06/2004 WED 13:05 FAX ©OOl/OOl
JOEL URETA
3280 Roosevelt Street
Carlsbad, CA 92008
October 4,2004
RECEIVED
CCT 0 r 2004 CityofCarlsbad
2965 Rooseveh Street .,«Mi!!ILO£CARISBAD
Carlsbad, CA 92008
City of Calsbad Housing & Redevelopment Department
Attention; Ms. Rebeca Vazquez, Planning Technician
Re: Property Plans for 3280 Roosevelt Street /RP03-02
Dear Rebeca,
Further to our telephone conversation on Friday, October 1,2004,1 would like to go on
record that I wish to proceed with my redevelopment plans for the subject property noted
above. I have made changes to the originally submitted bmlding plans and will be
presenting new plans for your review by November 15,2004.1 have contacted and have
met with Mr. Harold Curry, a Planner & Designer, and asked him to draw the plans and
assist me with the permitting process. In addition, I have contacted and met with Mr,
Thomas Morrissey with Morrissey Constmction Company, who I will be hiring as my
contractor. As a team, we look forward lo providing you witii all the mformation that you
require in a timely fashion. I apologize for the delay on my part.
As per our telephone conversation. I have a 25ft wide by 140ft deep lot. My initial plans
call for 10ft front setback, 15ft wide by 100 ft long single-family residence. This will
leave 5ft side setbacks on each side ofthis single-family residence. Attached to this
single-family residence will be a 20ft wide by 20 deep garage. The rear set back will be
10ft. With a 20ft wide garage required by the planning dqpartment, this will leave me
with only a total of 5 feet to divide for side setbacks. I understand that Mr. Curry, as my
representative, or I will need to request a variance from the City ofCarlsbad planning
department. I would like to move forward on this process as soon as possible and would
like more infomiation on the process for applying for a variance and also the time fi^me I
should expect for a decision from the department once a request is made.
Rebeca, please let me know if there is any other mformation that is require at this time.
I look forward to working with you in redeveloping my property on Roosevelt Street.
Please feel free to contact me anytime via email at iuretaf5),att.net or via cell phone at 340
643 4665.
Sincerely,
Joel Ureta
cc: Mr. Harold Curry
Citv of Carlsbad
Housing & Redevelopment Department
September 16, 2004
BROOKS WORTHING
POBOX 1041
CARLSBAD, CA 92008
SUBJECT: URETA SECOND DWELLLING UNIT AND DETACHED GARAGE
(RP03-02)
The above referenced application has been on file for well over eighteen months
(February 26, 2003 to September 16, 2004). Notification was given on July 31, 2003
that the application was complete, along with a list of issues of concern that needed to
be addressed in order to complete the review of the proposed project. To date, our
office has not received any correspondence addressing the issues.
A decision will be needed within the next thirty (30) days to determine if you wish to
proceed with the processing of the application. If you wish to proceed, please provide
the information requested in the attached letter that was previously sent to you on July
31, 2003. Failure to resubmit the necessary plans addressing the issues by October 16,
2004, shall be deemed to constitute withdrawal of the application. If an application is
withdrawn or deemed withdrawn, a new application must be submitted.
Please contact my office at (760) 434-2813 if you have any questions and/or to apply
for a refund of any unused fees.
Sincerely,
Rebeca Vazquez
Planning Technician
^^: Joanne Juchniewicz, Engineering
2965 Roosevelt St., Ste. B • Carlsbad, CA 92008-2389 • (760) 434-2810/2811 • FAX (760) 720-2037
Citv of Carlsbad
Housing & Redevelopment Department
November 13, 2003
JAVIER URETA
3280 ROOSEVELT ST
CARLSBAD, CA 92008
Re: Ureta Single Family Residence 8c Second Dwelling Unit
3280 Roosevelt Street (RP 03-02)
Dear Javier:
I have enclosed a receipt showing payment of $1,050.00 for the balance
remaining to upgrade the Minor Redevelopment Permit to a Major
Redevelopment Permit. Based on our conversation today, you are awaiting
revised plans from Brooks Worthing. Once the plans are prepared, please
submit 5 sets to my office and we will continue with the processing of the permit.
If you have any questions regarding the application, please contact my office at
760-434-2813.
Sincerely,
CITY OF CARLSBAD
LORI H. ROSENSTEIN
Management Analyst
Enclosure
2965 Roosevelt St., Ste. B • Carlsbad, CA 92008-2389 • (760) 434-2810/2811 • FAX (760) 720-2037 @
Citv of Carlsbad
Housing & Redevelopment Department
August 4, 2003
BROOKS WORTHING
PO BOX 1041
CARLSBAD.CA 92018
Re: Ureta Single Family Residence & Second Dwelling Unit
3280 Roosevelt Street (RP 03-02)
In my last correspondence, dated July 31, 2003,1 stated the inclusion of the new single-
family residence Into the originally proposed project has resulted In an Increase In
building valuation, which changes the required land use permit from a Minor
Redevelopment Permit to a Major Redevelopment Permit. This change has also
resulted In additional filing fees. The permit processing fee for a Minor Redevelopment
Permit is $1,080 plus $150 for noticing costs. The fee for a Major Redevelopment
Permit is $1,980 plus $300 for noticing costs. Our records indicate payment of $1,230
has been received, which leaves a balance due of $1,050. Please remit the remaining
balance to the Housing and Redevelopment Department for final processing.
Finally, please note, Fire Department comments have been received and no comments
or concerns were raised regarding this specific application.
If you have any questions regarding the information contained in this letter, please
contact my office at (760) 434-2813.
Sinq^ly,
LORI H. ROSENSTEIN
Management Analyst
2965 Roosevelt St., Ste. B • Carlsbad, CA 92008-2389 • (760) 434-2810/2811 • FAX (760) 720-2037 ^
Fee Processing for RP030002
Calculated F%
Additional R
$2,280 00
$2^.001 {SeMi
$U30 0Q|'*Detaiiri
$1,050
lncludedSffi^l^WlNjii^M>l<^l^ f
Include Trus^ tLa^sc^ons[jn Paiiineni;.Petails. f
Pay Full Balance
Partial Payment
Pay Speafic
item[s1
Trust Acodunt
Transaction(s1
Pay Deferred
Assess Additional
VoidPayment^''^
RepriniilRe^^
Print Grid
Fee Iteins
52 POSTAGE-PURCHASING $300.00! $150.00} $150.00^00114104904
280 ENVIRONMENTAL $0.00 $0.00 $0.00 00132104812
1110 RD-MINOR/MAJ PMT $1,980.00 $1,080.00 $900.00 80100004305
1111 RD-APPEAL $0.00 $0.00 $0.00 80100004813
111B RD-OTHER FEES $0.00 $0.00 $0.00 80100004819
^^^^^^^^^^^^
City of Carlsbad
Housing & Redevelopment Department
July 31,2003
BROOKS WORTHING
PO BOX 1041
CARLSBAD.CA 92018
Re: Ureta Single Family Residence and 2""^ Dwelling Unit - 3280 Roosevelt Street (RP 03-02)
The items requested from you earlier to make your Major Redevelopment Permit, application
no. RP 03-02, complete have been received and reviewed by the Housing and Redevelopment
Department along with other appropriate City departments. It has been determined that the
application is now complete for processing. Although the initial processing of your application
may have already begun, the technical acceptance date is acknowledged by the date of this
communication.
Please note that although the application is now considered complete, there may be issues that
could be discovered during project review and/or environmental review. Any issues should be
resolved prior to scheduling the project for public hearing. In addition, the City may request, in
the course of processing the application that you clarify, amplify, correct, or otherwise,
supplement the basic information required for the application.
To assist in expediting the processing of the application a list of remaining issues of concern
and information needed for clarification has been attached. These issues must be addressed
prior to staff making a recommendation on the project. Since these changes will require
changes to the plans, please submit 6 sets of the revised plans to the Housing and
Redevelopment Department for final review and preparation of final conditions. If you have any
questions or wish to set up a meeting to discuss the application, please contact my office at
(760) 434-2813.
Sincer
LORI H. ROSENSTEIN
Management Analyst
c: Joanne Juchniewicz, Engineering
2965 Roosevelt St., Ste. B • Carlsbad, CA 92008-2389 • (760) 434-2810/2811 • FAX (760) 720-2037 ^
%
ISSUES OF CONCERN
No. RP03-02
Staff has completed a review of the subject project for issues of concern. The following items
need to be resolved or adequately addressed prior to staff formulating a recommendation on
the proposed project: (Please note, the issues are listed under the department which identified
them as an area of concern.)
ENGINEERING:
Staff has conducted a review of the project for engineering issues of concern. The following
engineering issues must be resolved or adequately addressed prior to staff making a
determination on the proposed project: (Note: many of these issues were raised in our last
correspondence, but were not included in the revised plans.)
1. On the site plan, please include the following information:
a. Correctly show right-of-way width on Roosevelt Street.
b. Show all existing and proposed improvements (specifically water, sewer laterals
and meter).
c. Show existing and proposed topography/spot elevations within and adjacent to
the site.
d. Show drainage patterns (existing and proposed) on the site. (A soils engineer
recommendation/approval is required for the buildings to be located 3 feet from
property line instead of the required 5 feet).
e. Include a brief legal description of the subject property.
If you have any questions regarding engineering issues, please contact Joanne Juchniewicz in
the Engineering Department at 760-602-2775.
HOUSING & REDEVELOPMENT:
1. The scope of the project has changed from the original submittal and now includes
construction of a new single-family residence in addition to the second dwelling unit and
detached garage. This has resulted in an increase in building valuation. Since the
building valuation now exceeds $150,000, the permit changes from a Minor
Redevelopment Permit to a Major Redevelopment Permit. Additional filing fees will be
required and the project must go before the Housing and Redevelopment Commission
(City Council) In addition to the Design Review Board.
2. A variance is required to reduce the side yard setbacks from 5 feet to 3 feet. The
required findings have been attached. Please provide written justification to grant the
requested variance.
3. Please add the following information to the site plan:
a. Lot coverage in the form of a percentage.
b. Open space percentage. Area that qualifies as open space includes; landscaped
planters, open space pockets, balconies, and patios. No parking spaces or drive
aisles are permitted in the open space.
c. Show all adjacent uses.
4. Show building heights on the elevations sheet.
% %
5. Provide a preliminary landscape plan for4hesite4A/ith the following-information:
a. Typical plant species, quantity of each species and their size.
b. Percent of site used for landscaping.
6. As part of the design review process, the Design Review Board must be satisfied that
the applicant has made an honest effort to conform to each of the ten basic principles
outlined in the Village Design Guidelines. Staff recommends that more attention be
given to principle No. 7 stating, "Buildings shall be enriched with architectural features
and details". A copy of the Village Design Guidelines has been enclosed for your use.
The ten basic design principles can be found page 119 and additional suggestions for
architectural treatment of residential structures can be found on pages 136-138.
To help expedite the processing of the permit application the following information is being
provided. Once all issues have been resolved, the project will be scheduled for a Design
Review Board hearing. The following items will be required for the hearing:
1. One (1) copy of a full-sized (24" x 36") colored site plan. (Needed 2 weeks prior to
hearing date.)
2. One (1) copy of full-sized (24" x 36") colored building elevations accurately depicting the
proposed mature landscaping and how it relates to the building. (Needed 2 weeks prior
to hearing date.)
3. Ten (10) sets of full size plans folded to 81^" x 11". (Needed 2 weeks prior to hearing
date.)
4. One (1) set of SVz" xll" black and white reduced plans. (Needed 2 weeks prior to
hearing date.)
5. Electronic files (in jpeg format) of the colored site plan and all building elevations
presented on disk or sent via e-mail to lrose@ci.carlsbad.ca.us (Needed 2 weeks prior
to hearing date.)
For questions regarding Housing & Redevelopment Department comments, please contact Lori
Rosenstein at 760-434-2813.
FIRE:
Fir6 Department comments are forthcoming and will be sent to you in a separate
correspondence.
Citv of Carlsbad
Housing & Redevelopment Department
April 2, 2003
BROOKS WORTHING
PO BOX 1041
CARLSBAD, CA 92018
Re: Ureta 2"^^ Dwelling Unit & Detached Garage - 3280 Roosevelt Street (RP 03-02)
My last correspondence, dated March 28, 2003, did not include comments from the Engineering
Department. Prior to the Engineering Department establishing conditions for the proposed
project the following information is needed:
1. Submit Preliminary Title Report for the subject property current within the last 6 months.
2. Please revise the site plan to include the following:
a. Draw at a scale of 1" = 10'.
b. Show right-of way width of the alley as well as Roosevelt St. adjacent to the project.
c. Show all existing and proposed improvements (curb, pavement, sidewalk, utility poles,
fire hydrants, street lights, water and sewer laterlals/meters, etc.) within and adjacent to
the subject property.
Show existing and proposed topography/spot elevations within and adjacent to the site.
Show drainage patterns (existing and proposed) on the site.
Include a brief legal description and Assessor Parcel Number of the subject property.
d.
e.
f.
If you have any questions regarding the engineering comments contained in this letter please
contact John Maashoff in the Engineering Department at 602-2747.
Sincer
LORI H. ROSENSTEIN
Management Analyst
c: John Maashoff, Engineering
2965 Roosevelt St., Ste. B • Carlsbad, CA 92008-2389 • (760) 434-2810/2811 • FAX (760) 720-2037 @
Citv of Carlsbad
Housing & Redevelopment Department
March 28, 2003
BROOKS WORTHING
PO BOX 1041
CARLSBAD.CA 92018
Re: Ureta 2""^ Dwelling Unit & Detached Garage - 3280 Roosevelt Street (RP 03-02)
Thank you for applying for a Land Use Permit in the City of Carlsbad. The Housing and
Redevelopment Department, together with other appropriate City departments, has reviewed
your Major Redevelopment Permit, application no. RP 03-02. as to its completeness for
processing.
The application is incomplete, as submitted. The attached list includes information that must be
submitted to complete your application. This list of items must be submitted directly to the
Housing & Redevelopment Office. All list items must be submitted simultaneously and a
copy of this list must be included with your submittal. No processing of your application
can occur until the application is determined to be complete. When all required materials are
submitted to the Redevelopment Office, the City has an additional thirty (30) days to make a
determination of completeness. If the application is determined to be complete, processing for
a decision on the application will be initiated. In addition, please note that you have six months
from the date the application was initially filed, February 26, 2003, to either resubmit the
application or submit the required information. Failure to resubmit the application or to submit
the materials necessary to determine your application complete shall be deemed to constitute
withdrawal of the application. If an application is withdrawn or deemed withdrawn, a new
application must be submitted.
Please contact my office at (760) 434-2813. if you have any questions or wish to set up a
meeting to discuss the application.
Sincerely,
LORI H. ROSENSTEIN
Management Analyst
c: Debbie Fountain, Housing & Redevelopment Director
Joanne Juchniewicz. Engineering
Pat Kelley, Building
Greg Ryan, Fire
2965 Roosevelt St., Ste. B • Carlsbad, CA 92008-2389 • (760) 434-2810/2811 • FAX (760) 720-2037 ^
LIST OF ITEMS NEEDED
TO COMPLETE THE APPLICATION
No. RP 03-02
Housing & Redevelopment:
Submit five (5) sets of revised plans to the Housing & Redevelopment Department along with
the following information:
1. Please add the following information to the site plan:
a. Building setbacks for existing dwelling unit.
b. Width of alley along the rear of the property.
c. Location, height, and materials of walls and fences.
d. A summary table that includes the following:
• Lot area (total square feet);
• Existing zoning and land use (i.e. VR - District 5)
• Total building coverage;
• Building coverage for each dwelling unit; and
• Number of parking spaces
e. Width of Roosevelt Street.
f. Name of sewer, water and school districts providing service to the site.
g. General location of existing and proposed landscaping.
2. On the building elevations, please label proposed materials
3. Provide a separate 872" x 11" color and materials board.
4. Provide a letter indicating the prospective rental rate for the second dwelling unit.
5. Two (2) copies of the Preliminary Title Report (current within the last six (6) months).
6. Please note that once the application is found complete you must provide a complete public
notification package. In order to expedite this application you may submit the notification
package with your revised plans.
Public Notification Package: The public notification package shall include the following
information:
a. A typewritten list of the names and addresses of all property owners within a 600' radius
of subject property (including the applicant and/or owner). The list shall include the San
Diego County Assessor's parcel number from the latest assessment rolls.
b. 600' Radius Map: A map to scale not less than 1" = 200' showing each lot within 600' of
the exterior boundaries of the subject property. Each of these lots shall be
consecutively numbered and correspond with the property owners list.
c. Two (2) separate sets of mailing labels of the property owners within a 600' radius of the
subject property. The list must be typed in all CAPITAL LETTERS, left justified, void of
punctuation. For any address other than single-family residence, an apartment, suite or
building number must be included on a separate line. DO NOT include it in the street
address line. DO NOT TYPE ASSESSOR'S PARCEL NUMBER ON LABELS. DO NOT
provide addressed envelopes - PROVIDE LABELS ONLY.
UNACCEPTABLE UNACCEPTABLE ACCEPTABLE
Mrs. Jane Smith
123 Magnolia Ave., Apt #3
Carlsbad, CA 92008
Mrs. Jane Smith
123 Magnolia Ave.
Apt. #3
Carlsbad. CA 92008
MRS JANE SMITH
APTS
123 MAGNOLIA AVE
CARLSBAD CA 92008
Fire:
Fire Department issues which need to be resolved or adequately addressed prior to staff
making a determination on the proposed project are as follows:
Fire Protection Services staff is concerned with our ability to access the proposed second
residence in a timely and expeditious manner. The proposed site does not allow pedestrian
access on either side only from the frontage (through the primary residence) or from the alley
(which is a non-conforming Fire Lane).
The Fire Code specifically addresses those buildings (including homes) built in excess of 150
linear feet from the nearest Fire Department access. This proposed addition does not fall into
that category. However, the fact that the Fire Department would have to enter one building to
reach another is a situation that causes concern on many levels.
One method to reduce some of these concerns is that the Fire Department may require an
Automatic Fire Sprinkler system to be installed; this should address the 'fire' concern. The next
issue would be in the event of a medical emergency; our timely access could be substantially
compromised if adequate clear access is not provided.
Lastly, the plans should indicate the required 1 -Hour separation between the R-3 (residence)
and the U occupancy (garage), this requirement UBC 302.4 Exception. 3, requires Type X. 5/8
inch drywall each side to achieve the 1-Hr rating.
To discuss all Fire Department related concerns, please contact Deputy Fire Marshal Gregory
Ryan at (760) 602-4663.