Loading...
HomeMy WebLinkAboutV 89-03; Robert Hale; Variance (V) (4)Architecture 8 Planning wuim Y. lkwrh. ArchlfuI ' Ilob.r~ 3 Sunrz P.O. Box 4651, Cmrlsbd, CA 02008 (619) 434.0474 June 13, 1989 Mr. Don Neu Planning Department City of Carlsbad 2075 Las Palmas Drive Carlsbad, CA 92009-4859 RE: Conditional Use Permit 89-6 & Variance 89-3 Dear Mr. Neu: Thank you for your letter of June 7 regarding the issues of concern for the Pelican Cove application (CUP 89-6 61 Variance 89-3). On the advice of Dee Landers and Charlie Grimm we made our CUP and Variance application based on what the ordinance would allow at the time of application (total of 6 units, 3 new & 3 existing) with the understanding that the number would be revised immediately upon the Planning Commission's approval of the change to the zoning ordinance allowing more units. That ordinance was approved last Thursday, June 7 to allow 8 units. We are hereby requesting that our applications for CUP 89-6 and Variance 89-3 be revised throughout to read 118tt units instead of 11611 . The parking layout presented with our application will allow 8 units. Enclosed per your request are 8 new sets of our submittal drawings that reflect the changes and additions that you have requested noted'as follows: Planning Comments: 1. The floor plan drawings have been expanded to include the existing spaces including the owner's / managerls unit as well the proposed additional units. Please note that it is precisely our intent to create an additional guest room in the existing structure as delineated on the enclosed drawings. Mr. Don Neu Page 2 June 13, 1989 Planning Comments (continued): 2. An exterior lighting design has been included in the revised submittal set. Please refer to sheet 8 for first floor and site layout and sheet 4 for upstairs exterior lighting. Engineering Comments: 1. At Charlie Grimm's request, we have already submitted an application for a lot line adjustment. (ADJ-379) was made on May 10, 1989, we have received initial comments and the surveyor is currently addressing those plan check issues. The application It is important to note that it is our understanding that this lot consolidation and our CUP / Variance applications are connected if not literally at least in processing sequence and will all be reviewed for approval at the same time. The lot consolidation cannot be recorded unless we have CUP / Variance approval to go with it. Should the CUP / Variance application process unwind, it is important to Mr. Hale that the parcels remain separate. 2. A letter from the Civil Engineer who designed and specified these sump pumps is attached. The pumps are designed to serve an area over three times the size of our project, both lots included. 3. Per your red-line notes: A) Note #24 has been added to the existing driveway at the existing Pelican Cove Inn. B) A copy of the Title Policy issued at the closing of escrow for the easterly parcel is attached for your review. Both parcels are now owned by the Hales. Mr. Hale has been working with staff for over a year regarding this expansion to the Pelican Cove Inn. Now that the ordinance has been expanded, he is anxious to proceed as quickly as possible. As I mentioned in our telephone discussion last week, we are available to meet with you at any time as soon as possible and can often meet on a moments notice. If you feel a meeting is appropriate, please schedule one at your earliest convenience. Should you have any questions, please do not hesitate to call. 1 Ø AN SMITH ENGINEEF~S, INC. CONSULT I NG CIVIL ENG I N E ERS 2656 STATE STREET CARLSBAD, CALIFORNIA 92008 PHONE (619) 729-8981 August 22, 1988 Mr. Robert Hale 320 Walnut Avenue Carlsbad, CA 92008 SUBJECT: PUMP CAPACITY FOR PELICAN COVE, CAFUSBAD, CA J.N. 6139 Dear Mr. Hale: The pumps specified for the above project were two 3 H.P., 1750 RPM Hydromatic S4F submersible sewage pumps rated @ 500 GPM with a 5 foot head. These pumps were designed for a 10 year frequency storm, 1.00 acre drainage area (approximately 1/4 of block), and with only one pump being used at a time. If you need any more information regarding the capacity of these pumps, please call. Sincerely, BRIAN SMITH ENGINEERS, INC. - Vice President and Principal Engineer CCH : gh