.- ENGINEERING GEOLOGIC EVALUATION OF
DEVELOPMENT FEASIBILITY, PLANNED NEW DWELLING,
VACANT LOT ON SHORE DRIVE,
CARLSBAD, CALIFORNIA
FOR
-
-
,.:..‘.
-
,;‘. - !
ENGINEERING DEPT. LIBRARY
City of Carlsbad 2075 Las Palmas Drive
CarlsbaQ CA92009-4859
-
-
-
i \: -----.A--LA-A-----I-.
Sirkei Index Map ,
-
:.
- -.
‘.. ‘.
20’ “69’
-
Topoqr-aphii Index Map ,
-
. >
-
william R. munson associates consunlrg engirleefing Qedqirtr
r
August 22, 1986
Coastal Commission
Application No. 6-86-443
-
Mr. Hal Heers
1802 Parliament
Leucadia,, CA 92024
-
SUBJECT:
8
Engineering Geologic Evaluation of
Development Fbasibility, Planned New
Dwelling, Vacant Lot on Shore Drive,
Carlsbad, California
- Leual Description: Lot ,lO; Terramar Unit #l, Map No. 2696
'portion tit H, Map NO. 823: A.P.#210-06-10
:
- Gentlemen:
Pursuant to the request and authorization of Mr. Lee Riley, your
governmental advocate, .-the undersigned conducted a limited
i ! 1 -'
-~
examination of the subject property and proximity during August
1986. The purpose of the field work and study was to provide
the basis for evaluating the feasibility of constructing a
planned new dwelling at the site, from an engineering geologic
standpoint.
‘-
-
32302 comb copistrono . suite 207 . son juon copistrono . 92675 . p,o, box 857 l (714) W-~QOT
. :
-
Mr. Hal Heers -2-
Reportedly, the work and this report were prompted by a desire
to preliminarily document exposed and apparent attendant
geotechnical conditions for project submittal to the California
Coastal Commission.
-
-
-
-
-
This report summarizes the findings of the limited examination
and study, and presents relevant conclusions and recommendations
for decision-making in this matter.
SCOPE
The field work comprised'visual examination of the lot terrain
and attendant appurtenances, and 'the exposed terrain and
structures on contiguous properties. Moreover, the integrity of
the attendant near-surface soils was evaluated by random probing
with a hand-held narrow steel shaft (a device used for that
purpose); and relevantterrain configurations were measured by a
hand level/inclinometer. Due to a gunited bluff face, the
identification and classification of the concealed earth
materials was made several hundred feet southerly where bedrock
and overiying unconsolidated terrace deposits are'exposea in the
bluff.
_ . .
The field work and preparation of this report were augmented by
the writer's knowledge and understanding of local geologic
conditions and associated physical impacts imposed thereon by
residential hillside development: and review of the following
technical documents:
-
- ’
I Mr. Hal Heers
-
-3-
1.
-
L
-
-
2.
3.
4.
5.
:.
C.M. Engineering Associates, 3 July 1986, Plot Plan
for Heer Residence at 19-scale (W.O. 06-84-14)
V'.... 'Frdnk.. Gonzales and Associates Architects, 30 June ., -. 1986, Building Plans,.-Including Foundation Plan, Floor
Plan, Section,--~ Rbof Plan and Elevations (7-sheets) - --,.~~ .'. ,-' Jpb-No. 2054.
Weber, Harold F., 1963, Geology and Mineral Resources
of Ban Diego County, California, County Report 3 of
the California Division of Mines and Geology.
Young, J.M. and Berry, R-W., April 1981, Tertiary
Lithostratigraphic Variations, Banta Margarita River
to Agua Hedionda Lagoon, Paper in Geologic
Investigations of the Coastal Plain, San Diego,
California prepared for the 1981 San Diego Association
of Geologists Field Trip (Pages 33-51).
: Lajoie, K.R., et al, November 1979, Quaternary Marine
Shorelines 'aad Coastal Deformation, San Diego to Santa
Barbara, California, Paper Prepared for the 1979
Geologaical Society of American Annual Meeting.
The scope, of the examination and study did not include
subsurface exploration (i.e., backhoe tr'enches or drilled I _,
borings), nor soil engineering field/laboratory testing and .
analysis.
-
-
-
-
Mr. Hal Heers
Accordingly, the field work conducted is classified surficial,
whereby evaluation was limited to surface and very near-surface
conditions, apparent and obvious to the writer, and
interpretations made therefrom based on published (i.e.,
documented) geologic/topographic conditions. Evaluation of
subsurface conditions, and conclusions made therefrom, which
were not reflected at the ground surface or by available
documented geologic relationships, are beyond the scope of the
field examination and study, and this report. Such information
would have to be secured from a comprehensive subsurface
geotechnical, investigation in the+form of exploratory drilled .,.~ .~ ~,
borings and/or excavated trenches. ':
Within the limitations of the subject field examination, the
following attendant features and conditions were recorded and/or
evaluated: ;
0 Composition/geometry and integrity of exposed earth
materials at the surface and in the near-surface.
0 Man-made alternations of the terrain.
0 Evidence, if any, of'prior ground instability.
0 Conditions conducive to site stability/instability.
0 Engineering properties of earth materials, including
expansivity, based upon visual examination.
-
-
Mr. Hal Heers -5-
.
-
PRINCIPALS
- 0 Owner: Dennis & Carol Troish
6830 Van Buren Blvd.
Riverside, Calif. 92509
(714) 685-7481
-
-
-
-
-’
-
-
-
-
-
0 Architect: Paul Thoryk
Thoryk Incorporated
1202 Morena Blvd. Suite 400
San Diego, Calif.:. 92110
(619) 275-5612
0 'Civil Engineer/Surveyor: CM Engineering Assoc.
550 West Vista Way
Melrose Center
Vista, CA 9'2083
(619) 758-3689
0 Governmental Agencies: California Coastal
Commission/City of
Carlsbad
ENCLOSURES
0 Figure 1 - Geologic/Topographic Index Map . . .
0 Figure 2 - Site" Plan/Geotechnical Map
0 Figure 3 - Schematic Geologic Section A-A'
0 Figure 4 - Major Earthquakes and Recent Active Faults
in the San Diego Region...
-
-
, .’
-
-
-
-
-
-
.-
-
-
Mr. Hal Heers -6-
GITE DESCRIPTION
The seaside property is rectangular in shape, and fronts on the
westerly side of Shore Drive off of Carlsbad Boulevard in the
incorporated city of Carlsbad. The overall dimensions are
60-feet wide by [+/-I 150-feet deep to the mean high tide line.
It backs westerly onto the base of moderately high sea cliff
terrain and a racky beach beyond. The northerly and southerly
adjacent properties, which have approximately the same elevation
as the subject site, are developed with long established single
family dwellings.
Terrain
The seaward margin of the property is marked by a [+/-I 29-foot
high bluff face that is everywhere concealed by a gunite blanket
that, reportedly, was applied about 1972. Apparently, the
gunite constructionwas'hecessitated to protect the bluff from
wave action, and to a'rrest on-going landward erosion and gradual
reduction of the building site. Moreover, as viewed from the
property, the gunite bluff protection extends monolithically
many hundreds of feet northerly.and southerly of the site.
The configuration of the gunited bluff, from top to bottom,
comprises a [+/-I 14-foot high l/4:1 to 1:l precipitous cliff
that toes out at an irregular seaward sloping natural bench,
which terminates as a [+/-I 6-foot high near-vertical face above
the rocky beach.
-
- Mr. Hal Heers - -7-
-
-
-
-
-
-’
-
-
--
-
The existing 60-foot wide by [+/-I 95-foot deep lot pad is
relatively level' to very slightly inclined in a southwest to
seaward direction. The average pad elevation is [+/-I 39.5-feet
above sea level, which is approximately the street elevation.
The terrain between the elevated lot pad and the bluff comprises
a relatively uniform [+/-I 3:l (i.e. 18- to 20-degree) natural
slope.
Veoetation
The earthen surface supports a sparse to moderate growth of
thick-bladed ice plant, a few shrubs'at the southerly margin of
the lotpad, and an aloe-type plant at the northerly margin.
Improvements
0 A chainlink"fence, located 40-feet from the street,
extends across the width and along the boundary of the
property.
0 A masonry garden wall on the southerly property line
between the chainlink fence and the street. _ . .
‘0 The aforementioned 'gunite protection blanket on the
bluff. Although the details of construction of the
gunite blanket are unknown to the undersigned, the
condition of the gunite suggests that reinforcement
steel (or equal) was used and, possibly, the system
was anchored by rock bolts and/or earth anchors.
-
-
Mr. Hal Heere -8-
-
-
.-
Moreover, it was apparently constructed with a
subdrain facility for the collection and disposition
of migrating groundwater, as indicated by an exposed
[+/-I 3-inch diameter outlet drainpipe that extends
through the gunite near the base of the bluff.
DRAINAGE
Lot drainage comprises sheet flow runoff of incident rainfall
that is received on the gunited bluff and directed to the beach,
below. Drainage from the east is intercepted by Shore Drive and
conducted elsewhere to a storm drainlfacility; whereas, runoff
on the southerly- and northerly-adjacent lots drain to the bluff
substantially within their property boundaries.
+ PLANNED DEVELOPMENT/CONSTRUCTION
According to the Reference 2 building plans, the site is to be '; ,~ i..b ,?*
developed by constructing a [+/-I 4400-square foot 2-story : dwelling (as viewed from the seaward side) with a j-car garage. ? ;' .r,- ,a
The garage floor is to be [+/-I l-inch below the street level.
I I_ i:
The main floor of the dwelling', which is to be at approximately' !"'
street level, will include two bedrooms, two bathrooms, a living
room, dining room, kitchen, study and laundry room. The lower
level will be a basement, the floor of which will be 9- to
.-
lo-feet below- existing grade. A distinguishing feature of the
is that the dominant gable roof is to be 27.5-feet high
.’ ~ - I - -
-
.- ,s - -. if! \ Ii T 7 !I ~ Y b - -
Mr. Hal Heers -9-
relative to the front yard grade to accomodate a 2-story high
front room and master bedroom at the seaward end. Moreover, the
design Will create a maximum 16-foot high attic above most of
the garage and dwelling. The set-back of the rear building line
from the top of the 3:l earthen seaward elope will be minimum
12-feet.
The only appurtenance shown on the plans is a 6-foot deep wooden
deck cantilevered off the seaward end of the building to provide
access from the living room and master bedroom, However, other
improvements will undoubtedly include a con.crete driveway,
concrete flatwork, garden walls, and'rear yard retaining walls.
The foundation system will include a maximum lo-foot high
retaining wall to form the back wall and side walls of the
basement. Accordinglyi"'the retaining wall is to provide support
for the peripheral lo'ads of the superimposed upper floor and
roof: whereas, poets supported by pad footings will support the
interior and westerly (i.e. seaward) wall loads. Moreover, the
foundation system for the garage, study and front entry will _ /
consist of conventional continuous footings, two pad footings
and a grade 'beam footing across the garage openings. There will
also be a pad footing to support the canopy over the front entry
L walkway.
-
- .
Mr. Hal Heers -10" .
\ The ground floor system will consist of concrete slab-on-grade.
NOTE: The Reference 2 plane did not include retaining wall,
foundation or floor slab details.
Apparently, earthwork grading will be limited to an estimated
maximum [+/-I 10.5-foot deep excavation to form the basement
and basement-level rear yard. Moreover, the rear yard
excavation will undoubtedly be a lldaylight" cut at the
seaward-facing elope. The plans do not include a grading plan;
nor do they show perimeter rear yard retaining walls that will
probably be required to support the construction cute below the
side yards and along the southerly and northerly property lines.
/ All excavated earth materials will be exported from the site.
-
GEOLOGIC SETTING ; :
Regionally, the property is situated on the coast plain at
the seaward margin of .the foothills of the Santa Ana
Mountains, which comprises a part of the Peninsular Range
Province. Locally, the underlying Santiago formation bedrock of ~ ,.
Eocene age is capped by Quaternary marine terrace deposits.
GEOMORPHOLOGY
The near-level to gently seaward eloping surface of the building
site is a substantially natural platform that is widespread in
the coastal plain of the Carlsbad-Oceanside area of northwest
San Diego County. There, it is generally [+/-I 40-feet above
sea level.
- II ,.
.’ Mr. Hal Heers - -ll-
-
,-
-
The feature comprises the remnant of a"late Pleistocene marine
terrace and superimposed ancient beach deposits that emerged
from the ocean 85 to 120 thousand years ago. The sandy beach
sediments, termed marine terrace deposits, were formed on a
trancated bedrock platform (i.e. marine terrace) cut by wave
action 'at a,time when sea level was roughly 20- to 4%feet below
the present ocean level (i.e. during Pleistocene Ice Ages when
global glaciation caused a corresponding lowering of sea level).
- The process of the ensuing emergence to the present terrac~e
level has been tectonic (i.e. by mountain building forces) at a -
continuing very gradual rate. Although imperceptible, the rate
of movement is measureable by sophisticated equipment over a
period of many months or years.
-
- GEOTECHNICAL CONDITIONS
Earth Materials
0 Fill - None
-
-
0 Marine Terrace DSDOSitS (symbol -Qmt) - The gently
dipping wave-cut marine terrace platform (i.e.
bedrock) is capped by an estimated 25- to 30-foot , ,. thick prism of-pale yellowish brown slightly silty to
silty, very fine to medium grained sand. These
ancient beach sediments are dense, very friable to
weakly cemented (imparted by iron oxide and natural
salt compounds), non-expansive, very permeable, and
very erosive.
- t -
Mr. Hal Heers -12-
-
0 Bedrock (symbol - Ts) - The underlying Santiago
formation bedrock forms the lowermost [+/-I 12- to
-
-
-
-
-
-
-
-
-
-
15-feet of the bluff. It consists of crudely
stratified dark gray-brown clayey siltstone that is
very stiff to hard, and exhibits moderate to high
expansivity. Moreover, the fine grained bedrock is
generally impermeable and relatively erosion
resistant.
By contrast, the bluff comprises a near-vertical rise
above the sandy-gravelly beach and a seaward-inclined
ledge, above -- both of which are comprised of
bedrock: and a variably-inclined precipitous erosional
cliff face in the sandy marine terrace deposits. Of
course, the features are concealed by the gunite
blanket. ""
The circa 1972 gunite blanket appeared to be
substantially in place as orignally constructed. The
only evidence of marked distress were a vertical crack
at the face of the gunited vertical rise above the
beach, and some curvilinear cracks on the inclined
ledge. They are attributed to toppling of the bedrock
along a joint fracture, and to expansivity pressures,
respectively. Notwithstanding, the gunite face also
exhibits several minor hairline cracks. .
-
.-
-
’ Mr. Hal Heers . -
-
-
-
-
-
-
-
-
-
-
Geolouic Structure
Based on outcrops in the general area, available published data,
and interpretation of site conditions, the following
determinations are made:
0 The marine terrace sands are very crudely to
indistinctly stratified, with low angle seaward dips.
0 The Santiago bedrock strata dip 3- to °rees
seaward (i.e. westerly), and are cut by a system of
high angle (i.e. near-vertical) joint fractures that
strike roughly north'south and east-west,
respectively.
Groundwater
Groundwater seepage in ocean bluffs is commonplac,e in the
coastal margin of Southern California. Typically, water derived
from incident rainfall and irrigation 'percolates downward
through the relatively permeable granular terrace deposits until
reaching the relatively impermeable wave-cut surface of the
bedrock. The groundwater then, migrates seaward at the top of
the bedrock until it **daylights8V as seepage in the bluff.
Although not evident at the site or proximity due to the gunite
blanket, the above described relationships are believed to
exist.
-
-
_
-
-
-
-
-
,-
-
-
-
-
-
-
-
-
Mr. Hal Fleers -14-
BLUFF/SLOPE STABILITY
The attendant terrain exhibits no evidence of landsliding, or
inclination thereof. Moreover, there is no evidence of
significant downslope creep movement in the earthen surface or
in superimposed structures. A cursory examination of structures
on the contiguous properties likewise revealed no evidence of
distress. Accordingly, the apparent stable condition is
attributed to the coarse grained, dense and massive
characteristics of the thick sequence of terrace deposits.
DONNSLOPE CREEP PHENOMENA . /
The attendant terrace deposits are subject to downslope movement
within the outermost few feet of the slope face. Moreover, the
margin of the'building pad nearest the slope is also subject to
movement.
The natural phenomena affects nearly all sloping terrain to some
degree, is most dramatic in fine grained (clayey) soils, and
affects granular soils least. It is tenned'downslope creep, and
the affected zone below the slope face and pad margin is termed . .
the creep zone.
By definition, downslope creep is the imperceptibly slow
downslope movement of surface and near-surface earth materials
under the perpetual force of gravity. The rate and magnitude of
downslope creep is a function of slope height, slope
inclination, soil density, expansivity and ground moisture.
6
Mr. Hal Heers - -15-
.I SEISMICITY/FAULTING
There are no active or potentially active faults that are known
to transect the property. The nearest known location of major
-
faulting is the fault zone [+/-I 3-miles offshore, which is
associated with the Rose Canyon Fault. The Rose Canyon Fault,
which has been classified potentially active to possibly active
(i.e. it is controversial), may be linked with the active
Newport-Inglewood Structural Zone that parallels the coastline.
The magnitude 6.3 Long Beach earthquake was caused by a sudden
strain release along this structural zone of faulting.
Accordingly, a magnitude 6.0 and'6.5 earthquake may occur
-
along the fault system within the economic life of the structure
(iye., 50 to 100 years).
Of course, there are numerous other faults in the Southern
California region that;have the potential for generating strong
ground shaking at the site. Accordingly, the planned
-
~-
-
-
-
-
-
construction should incorporate standard aseismic design .,
considerations to mitigate the effect of ground shaking induced
by a moderate earthquake along a nearby fault (i.e., ,. -,.
Newport-Inglewood, Rose Canyon, and Whittier-Elsinore), or by a
major or great earthquake generated along a distant fault (i.e.,
San Andreas'or San Jacinto).
* - Mr. Hal Heers -16-
-
-
-
-
CONCLUSIONS
1. Based on the limited investigation and study described
heretof,ore, it is the opinion of the undersigned that the
planned construction and associated grading for a new
dwelling and appurtenances at the subject property is
feasible from an engineering geologic standpoint, subject
to'the recommendations rendered hereinafter. '
2. The attendant terrain exhibits no deleterious geologic
conditions that would preclude implementing the planned
residential development, provided foundations bear suitably
in competent natural ground foruniform support, and the
planned seaward disposition of site drainage be implemented
to minimize or preclude slope erosion.
3. Attendant' subgrade earth materials at the building site
exhibit soil expansivity potential in the range of low to
nil (i.e. marine terrace deposit sands).
4. The circa 1972 protective g-unite blanket on the bluff face
has affectively arrested bluff regression, which is an
otherwise active process along the Oceanside-Carlsbad
coastline. Moreover, except for a few open cracks, the 1 ,. gunite system has "survived the test of time (i.e. 14+
years) during which it has been battered by numerous
assaults by a storm whipped ocean.
5. In the absence of evidence to the contrary (in the form of
marked distress), the gunite blanket is inferred to have a
functional eubdrain system to effectively collect and
-
-
- 1
Mr.
6.
7.
8.
9.
10.
-
Hal Heers - ' / -17-
dispose of migrating groundwater along the interface
between the clayey siltstone bedrock and the overlying
marine terrace sands.
Surf icial sandy terrace deposits on and near a descending
slope are prone to minor downslope creep movement.
The planned excavations should encounter only sandy terrace
deposits. Accordingly, they may .be made utilizing
conventional excavation equipment.
Groundwater should not be problematic to the planned
construction, or to the continued stability of the bluff,
provided the inferred subdrain system does actually exist,
and it continues to function in+an efficient manner.
Being located in Southern California, the site is subject
to strong ground shaking by nearby or distant earthquakes.
However, 'the performance of structures built in compliance
with current Uniform Building Code criteria and founded in
firm ground, such as occurs within the underlying subgrade
earth materials,,, has generally proven to be satisfactory
under conditions of earthquake-induced ground shaking.
Local mapped faults and inferred fault traces are deemed
inactive in the classical sense, and not problematic from 1 . .
the standpoint of" earthquake induced ground rupture or
shaking.
BECOHMENDATIONS
5 1. A subsurface geotechnical investigation of the site should
L be conducted prior to finalization of foundation and
8 grading plans. The purpose, of course, is to verify the _~ _,.. ..,~ -.
?
preliminary findings described heretofore, and to provide
.- ("
-
-
the basis for specific reccmmendations including:
Foundation design criteria, structural set-backs, site
drainage, grading specifications, and in-construction
inspections.
2. All foundations for structures should be founded in
competent/dense terrace sand, which is generally 6- to
12-inches below the surface.
3. All structures on or near sloping terrain (i.e. ocean slope
and bluff) should have a minimum embedment in dense terrace
sand to a depth determined by a minimum lo-foot horizontal
edge distance, measured from the bottom outside of the
footing to the face of the slope.
4. Pursuant to Table 29-B of the Uniform Building code, the
following'criteria are deemed applicable for foundations in
the bedrock:
0 Allowable foundation pressure - 2000 Ibs/sguare foot
0 Coefficient of friction - 0.35
0 Lateral bearing - 200 Ibs/sguare foot/foot of depth
5. Unless otherwise recommended by a qualified Soil Engineer,
the basement retaining wall system should be designed to
resist a surcharge equivalent to a level sloping backfill
(i.e., 30 pounds per cubic foot equivalent fluid pressure)
per the following appropriate Los Angeles City Building
Code section. The retaining wall system should be equipped
with an effective subdrain system to effectively preclude
the build-up of hydrostatic (i.e. porewater) pressures
behind the wall).
_-
.-
-
.~
.
‘ Mr. Hal Heers - -18-
I I I , 1 ! I I I / , I I / I. 1
SEC. 911309- REIA~NING WALLS
(I, De.lcn. Retntntng walls rba,, be deskned to reslat the later- .I prrrwre 01 the rc,mtned materla, delermlned In accordance vltb rccrpted englneerlng prlnclpler
The adl chrmcttrlttlu and design crlterla ncee33~y for such m dc1rrmlnrUc.n shall be obldned from a speeln, 1oundaUon In- mtlgstien perlormed by an agency acceptable ,o the De- partnvnt. The Departmtnt shall approve such ehcmcterlstiw ,x”d erltrrla only rfter rccelvlng II wrltten oplnlon from the In- vestlga:ion agency togelhtr wltb tuhs(nntlatlng cvlde”ce.
ESCEPT,ON: FrrcsC.ndlng Wdk WMCA or* “Of over is, (11 hdghl m baaelncnt Wdb lahkh horn .pona Of IS’ m IUS bdtarsn anpporw may bs ddgned ,I ocoordancs with Sub- rrction .lbJ of this Seelion.
140 DIV. 23 fee. ¶1.2309 ICmU
TABLE NO. 23-E
surrun slope 61 BAlIbmd MM.e*ld* ,,“,I% to “STL
LEVRL 9 to *
: :: : 1 1.3 , 1% to 1
Rqulralent ““d,b-;;&t .;
;;
pi to 1 ii
* Where the surhce slow of tbc ret.laed .ath varle,, th. d&g,, mlop ah-11 be obtatned by canatcttng a Ilae Imm the top of the aall to the hlghcat point on the alope, whose lb-&, .m rlthl” the horlzonta, dhtanes fro,” t,,. .ten, cqua, to the stem helsht of Lbe “al,.
01) Arblby D&g” Method. Wrll# rblch ntaln dnlncd e.rtb and come wlthln the llmlts 01 the exceptton to Subsntlon f., ol this mcctton may be deslgned for a” lssumed earth pressure cqu,. ..knt to thlt exerted by a fluid relghtng not 1-s than ah”,.” k, TabIt 23-E. A vatilc~l component equat to one-third of the her,. mnW force Ed obt&,ed “my be auummd at the plane oI app,,c.- Uen of Vie lores
The depth 01 tbe retaIned. earth ahall be the rartleal dlatanc. below the ground 8urface measured at the rlll lace for ,tem de. str” or mewred .t the hec, of tbs lootIny for overtumlng and .Ihlh~.
te) Snrebmrm Any ruperlmposcd lcadl~, UEC t rctalncd a.t’th. ehrll be eonmldcmd ,a wrcharpa and pmvtde B 1~ I” the daknn. Unllomly dlstrlbuted loada may b, wmldercd u l qu,vr,. lent nddcd dr”tb ol rct.lncd earth. Sunhugs loading due o eon- Unuaus or Isolated lootings #ha,, be detsrmlned by the fc.i,or,ny t”Ormu!aa or by in rqulvalcnt method appmved by the Superlnten- daat ol BulldIng.
Resmnnt rAten Pmcc
03 Pb’ Yt=- x’+ b’
krtlon of L&em1 Reaulturt
,,==:: [(;:+t..-‘;‘) - (;)I ’
.
WhelW
R = Renultant latenl force meuurcd I” pounds prr loot r! -I, width
.
P = Reaultnnt surcharge load 01 conUnu”us or Isolated loot- Inga meraured ln pounda per loot ol length panllc, to the WUlL x = Dhtancs OK resultant lond from back lace 01 wall mm- awed In le& h = Depth below point 01 .pp,,e.“on of surcharge loadlng to X
top or wall roootlag rnrar”md In rcct E d = Depth of lateral reruNant b&w point 01 appllcatlon 01 mmharga loadlntt menawed In feet. z (tan-1 ;) = The angle In ndlan, whose ~tmgent ts eWm1 $
u1
0 to .!! . x
Sec. 912309 fCei3Ll - 211 DIV. 23 149
Lcmdn ~pplled Wllhla a horizontal distance equal to the wall stem belghf mauumd Irom.the back lace of tbe wall. ah.,, be eorutdered u “,rch.rga,
For Lolhted lootla~ barlag . xldth pvrlet to the rllt Icu ,han tbre. iset. -It” may be rsdueed to I,8 the ufculrted due.
l’tm results& lmtsnl force -R” shall be swumed to ba rnlform 1,~ tha 1s”~ ot fooUng par&s, to th. wall. md to dlmt”t,h unt- lormly to Vera at the dtatanca 2” beyond the ends of the foe”“~.
VirUca, p-m due to rxchargs applied to the top et the ‘wa,l footing tray be eo”sldersd to spread unllormly wlthln the lbnlta ol the .tem lad plane. maklng M .“gle ol 4Y rttb the rclt,saL
(d) Beulng Ramwe md Overtumlng. % a mulmlnn “tucil
on I”“eatl,catlon. The resultant of vcrtlen~ lands #hall pnss through the ml~dle onr.hlrd ol
(e) Rlctlon and Lmtent 8oU Rarswu +ii ctdnln~ wdlr rhmll be reatralned abrlnlt ulldlnr b lrletto” of the b-e .‘wl”st the earth. by lateml reslixt.nco of t K e ml,. or by. comblnallan of the two. Allownble frlctloa and Iateml sol1 values ahall not exceed thana illlowed In Dlvlslon 28 01 thts ArtI& except .s provided by . ,pec,a, foundatton lnrestl~~tlon.
When usea. keys Bhkll be umnncd to lower the plw~c 01 ltie- tlonnl reststnnee and the depth of lateral baarlng to the level al the bottom of the ksy. Lateral bearlng pressures shall be ummcd to act on a vetttcal pllns laatsd at tba toe of the looting.
(g) Spccl~l CondlUonr whenever. In the oplnlan of tbhc Super- tntendent of Bulldtng. the adequwey of tbba fcundsttc” m.ter,a, to @upport I wall 16 questlonable. m “““,“a, aweb. s eondltto” exlslr. or rheoever the mtalned earth Is so stratllle T or of such a character u to Invllldata ““mm, destrcn assumpttons. he may requlro n specla, foundatton lnvestlgatlon before approvtng .“y permlt lor such . “al,. -_ .,.A- .I
1
=: I
Mr. Hal Heers --
-
6.
- 7.
8.
9.
-
-
-
-
10.
11.
12.
- -2o-
Structures should be designed in accordance with applicable
earthquake standards contained in Chapter 23 of the Uniform
Building Code.
Unless otherwise recommended by a qualified Soil Engineer
based on chemical testing, Type II cemente should be used
in concrete for all construction.
The dwelling should be equipped with a roof
gutter-downspout system to minimize ground saturation and
nuisance water.
Bulk and/or fine grading of the lot shall conform to the
City of Carlsbad grading requirements.
All site and roof drainge received should be collected and
conducted to Shore Drive or to the beach in a nonerosive
manner. Moreover, surface water.should not be allowed to
pond on earthen areas (including planters), and no lot pad
runoff or drainpipe discharge should be allowed on the
unprotected sandy slope below the building site.
All slope and pad ~irrigation should be applied at minimal
rates to maintain health and growth. Automatic sprinklers
are not recommended. Mo,reover, slope planting should ~ ,. consist of drought tolerant, deep rooted and light weight
species.
All earthwork utility trench backfill and retaining wall
backfill, should be placed in a compacted manner in
accordance with recommendations, testing, observation and
-
.
Mr.
13.
14.
-
15.
-
-
-
-
16.
Hal Heere -21-
approval of a qualified Soil Engineer. Alternately,
retaining wall and utility trench backfill may consist of
washed concrete sand, pea gravel, or equal self-compacting
select earth materials.
Retaining wall design6 and specifications should include an
adequate subdrainage system and self-compacting backfill
such as pea gravel, or clean native earth materials
mechanically compacted under the observation and testing of
a gualified Soil Engineer. Moreover, the back side of
retaining walls should be effectively waterproofed. To
prevent the influx of surface runoff into the granular
backfill, the upper 12-inches of exterior retaining wall
backfill should consist of on-site cohesive soil compacted
to a firm'and unyielding condition.
The open crack6 in the gunite blanket should be caulked and
maintained to minlmize moisture from reaching the expansive
bedrock and, thu's to minimize future cracking.
Significant modification of the plans and specifications
should be reviewed and approved by the project Engineering
Geologist upon formulation,.to determine compatibility with ._ ,~.. , I,
attendant geotechnical conditions, and to provide
additional recommendations deemed necessary under the
circumstances.
To verify adequate excavation depth6 for foundations, the
project Engineering Geologist should be notified at least
40 hours in advance of the excavation to provide timely
inspection.
-
Mr. Hal Heers - -22-
CLOSURE
The undersigned Engineering Geologist warrants, that the work
performed in the preparation of this limited report was done in
accordance with generally accepted principles and practice in
the field of engineering geology. This warranty is in lieu of
all other warranties, either expressed or implied.
-
.-
-~
This report was prepared to aid those endeavoring to expedite
develoment planning of the site, and,to enhance future design
engineering and construction. The .findings and recommendations
are based on' information and data secured from field
reconnaissance mapping, the project plans, available
geotechnical data, and:,inter@retations made therefrom.
-.
Condition6 may be encountered during grading and/or construction
that may differ with those presented herein. Thus, the
Engineering Geologist should be requested to provide inspection -_- ,..._ ,.~ 1 . . of all excavations.
-
-
-
-
-
I Mr. Hal Heers \ -23-
-
.I
- Should you have any questions regarding this report, or if I may
be of further service, please contact me at your convenience.
-
- ,’ /
:j’
- ,, 1,.
C.E.G. 866
-
-
-
m/61m
Enclosures
Distribution: '(1) Addressee
(2) California Coastal Commission
(1) Lee'Riley.
-
-
-
-
-
p,~clF/i
omaw
I 0 I
,~,LEGEND Km 8 J Faults Alluvial Deposits El
T tm Son Moteo Formotion (Pliocene)
0 _ ,.
El Qmt Marine Terrace Son Onofre Formotion
Deposits (Miocene)
Ponds or Lagoons Sontiogo Formation
(Eocene)
0 Outcrop, i0c0tion
Topoaraphic/GeoIocric Index Map
Scale :. 1 ” z&3,115 ~
Source: Figure 1
-,.
-
.-
-
-
.-
-
..~
-
.-
-
-
‘-
\> /I, I t 75%
. L’JT II
dtrhrvsr crack ~~m;t; - b@. h&*1+ . -
c--
SlTE PLAN/GEOTECHNI CAL MAP Scale: Reference: ~~-*, 1” = 20’
FIGURE 2
I / I I I I I I I I I I /
.
_ . . .- e... .
. . . ..-. . ..-. . . . . . . . . .
. . . . . . - - .-.. _. . . . . - . . . .
. . . . .-
n c SCHEMATIC GEOLOGIC SECTION A-A’
c
ii
SEE ENCUX6D -mlrVa +~lOrz(~ OF term m6f+’
w
-
-
-
-
-
‘y?! r, >. “-1’9 ‘.... 3 +:.
9
. .:.,. ::..:.. l y..,‘:... .; ‘i .*. . . . . . c, -.. -- j
IIU ,:a :t..
w -.- T\ -.A .>& -‘,I,‘:,. (,i) . .
MAJOR EARTHOUA’KES- t-‘RECENT .ACTlVE FAULTS
IN THE
~SAN DIE& RE&ON, ‘CALIF.
Earthquakes of magnitude 6 and greater in the San Diego region.
Solid circles show epicenters with year of earthquake and magnitude or
maximum intensity. Open circles with question marks indicate poorly
known epicenters.
.-
-
-
-
FIGURE 4