HomeMy WebLinkAbout3184; CANNON ROAD WEST; GEOTECHNICAL INVESTIGATION; 1997-01-23& LEIGHTON AND ASSOCIATES, INC.
Geotechnical and Environmental Engineering Consultants
GEOTECHNICAL INVESTIGATION,
PROPOSED GOLF CART UNDERCROSSINGS,
CANNON ROAD AND HIDDEN VALLEY ROAD,
CARLSBAD, CALIFORNIA
January 23, 1997
Project No. 4930489-013
I.
Prepared For:
CARLTAS COMPANY
5600 Avenida Encinas, Suite 100
Carlsbad, California 92008-4452
3934 MURPHY CANYON ROAD, SUITE 13205, SAN DIEGO, CA 92123
(619) 292-8030• (800) 447-2626
FAX (6 19) 292-0771
January 23, 1997
Project No. 4930489-013
To: Carltas Company
5600 Avenida Enemas, Suite 100
Carlsbad, California 92008-4452
Attention: Mr. Charlie Kahr
Subject: Geotechnical Investigation, Proposed Golf Cart Undercrossing, Cannon Road and Hidden
Valley Road, Carlsbad, California
Introduction
In accordance with your request, we have performed a limited geotechnical investigation at the site of the
proposed Golf Cart undercrossings beneath Cannon Road and Hidden Valley Road in Carlsbad, California
(see Site Location Map, Figure 1, page 2). The undercrossings will be located at Station 43+00 and
Station 43+90 of Cannon Road and Hidden Valley Road, respectively. Leighton and Associates
j (Leighton) has previously performed geotechnical investigation for the Cannon Road Golf Cart
undercrossing at Station 27+00 and for the Armada Drive Golf Cart undercrossing at Station 3+60. As
part-of our study, we have reviewed the referenced reports and plans.
Proposed Undercrossing
We understand the proposed undercrossings will consist of aluminum structural plates with a width of 15
feet 4 inches, a height of 10 feet and a thickness of 0.125 inches. The Cannon Road tunnel will be 184
feet in length and the Hidden Valley Road tunnel will be 155 feet in length. The arches will be provided
with cover of approximately 7 to 10 feet of compacted soil backfill. The base of the structures will be
at approximate elevations of 157 and 166 feet mean sea level (msl) for the Cannon Road and Hidden
Valley Road tunnels, respectively. It is proposed to install the structural plate undercrossing in an open
excavation and place compacted backfill to achieve design grades.
Site Investigation
r Our site investigation consisted of the excavation of two exploratory borings; one at the Cannon Road
location and one at the Hidden Valley Road location. These borings were drilled to depths of 5 to 10 feet
below the tunnel invert elevation. Boring B-i was excavated at Station 43+90 on Hidden Valley Road
to a depth of 40 feet below existing grade. Boring B-2 was excavated at Station 43+00 on Cannon Road
to a depth of 27 feet below existing grade. Both borings were backfilled upon
I
I \ 1
PROJECT
SITES
Sbb
Base Map: Thomas Bros. GeoFinder for
Windows, San Diego County, 1995, Page 1126
CARLTAS COMPANY SITE Golf Cart Undercrossings
Hidden Valley Road LOCATION
and Cannon Road
Carlsbad, California MAP
0 2000 4000
I I
Approximate Scale in Feet
Project No.
4930489-013
TT Date 1042 889
1-27-96 Figure No. I
4930489-013
completion. The boring logs are attached as Appendix B. The approximate boring locations are indicated
on Figures 2 and 3, Boring Location Maps.
Geologic Conditions
Hidden Valley Road
As observed in Boring B-i, the area is underlain by a thin veneer (approximately 2 feet thick) of fill
soils, underlain by Quaternary terrace deposits consisting of dense silty sands and at depth (pipe invert
elevation) very dense silty sandstone to fine sandy, clayey .siltstone of the Santiago Formation at
depth. No ground water seeps were encountered in this boring at the time of our drilling. We
anticipate that the bedrock soil conditions will be similar at both ends of the tunnel. However, we
anticipate that potentially compressible colluvial materials overlie the bedrock in the vicinity of the
eastern end of the tunnel. Due to inaccessibility, we were unable to evaluate the exact extent of the
colluvium. During grading, the project geologist should observe the tunnel excavation in this area and
evaluate required removal depths if necessary.
Cannon Road
As observed in Boring B-2, this area is underlain by dense Terrace Deposits. The Terrace Deposits
consist of orange-brown to pale gray, damp to moist, dense silty sands. Practical refusal was
encountered at a depth of 27 feet below ground surface (bgs) on cobbles/rock materials. These
materials are not anticipated to be encountered at the proposed tunnel invert given their depth.
Faulting and Seismicity
Our discussion of the faults on the site is prefaced with a discussion of California legislation and state
policies concerning the classification and land-use criteria associated with faults. By definition, of the
JCalifornia Mining and Geology Board, an active fault is a fault which has had surface displacement within
Holocene time (about the last 11,000 years). The State geologist has defined a potentially active fault as
any fault considered to have been active during Quaternary time (last 1,600,000 years). This definition
is used in delineating Earthquake Fault Zones as mandated by the Alquist-Priolo Earthquake Faulting Zone
Act of 1972 and as subsequently revised in 1974, 1975, 1976, 1979, 1990, 1991, 1992, and 1993. The
intent of this act is to assure that unwise urban development does not occur across the traces of active
faults. The subject site is not located within any earthquake fault zones as created by the Aiquist-Priolo
Act (Hart, 1994).
Our review of available geologic literature indicated that there are no known active or potentially active
faults that transect Carlsbad Ranch. However, inactive fault zones were encountered in a number of places
within and adjacent to Carlsbad Ranch during previous investigations. Inactive fault zones were
encountered in the cut slope along the north side of Palomar Airport Road during previous geotechnical
j work performed at the site (Geotechnics, 1992) and in the eastern portion of the site (Weber, 1982 and
Leighton, 1991 and 1992).
4930489-013
The location of the proposed development can be considered to lie within a seismically active region, as
can all of Southern California. The Rose Canyon Fault Zone which is located approximately 3.5 miles
to the west of the site is considered to have the most significant seismic effect at the site from a design
standpoint. A maximum probable earthquake of moment magnitude 6.25 on the fault could produce a peak
horizontal ground acceleration of approximately 0.30g at the site. For design purposes, an effective ground
acceleration of 0.40g based on the Uniform Building Code criteria (ICBO, 1994) may be assumed.
Seismic Considerations
The principal seismic considerations for most structures in Southern California are surface rupturing of
fault traces, damage caused by ground shaking and/or seismically induced liquefaction or dynamic
settlement. Theprobability of damage due to ground rupture is considered minimal since active faults
are not known to cross the site. Ground lurching. due to shaking from distant seismic events is not
considered a significant hazard, although it is a possibility throughout. the Southern California region.
Ground Shaking
The seismic hazard most likely to impact the site is ground shaking resulting from an earthquake on
one of the major regional faults. As discussed above, a maximum credible event on the Rose Canyon
Fault Zone (considered the design earthquake for this site) could produce a peak horizontal bedrock
acceleration at the site of 0.30g and an effective ground acceleration of 0.40g.
Liquefaction/Dynamic Settlement
Liquefaction of cohesionless soils can be caused by strong vibratory motion due to earthquakes.
Research and historical data indicate that loose granular soils underlain by a near-surface ground water
table are most susceptible to liquefaction, while the stability of most silty clays and clays is not
adversely affected by vibratory motion. Due to the relatively dense nature of the onsite Terrace
Deposits and Santiago Formation and the absence of a near surface ground water table, the potential
for liquefaction on the site due to the design earthquake is anticipated to be very low.
Laboratory Testing
Representative samples of the soils encountered were obtained for laboratory testing. Samples were
obtained at the approximate invert of the proposed structures and were tested to evaluate the engineering
characteristics of the onsite soils. For soil-bearing values, the soils were judged to be similar to those
previously tested during previous investigations of the Carlsbad Ranch. The chemical characteristics of
the soils are as follows:
-4-
4930489-013
)
Hidden Valley Road Undercrossing:
Sample B-I at 22 to 25 feet
pH-7.6
Soluble Sulfate Content - <0.005% (negligible sulfate attack per tJBC, 1994)
Minimum Resistivity - 380 ohm-cm (severe corrosion potential)
Chloride Concentration - 500 ppm = 0.05% (moderate corrosion potential)
Cannon Road Undercrossing:
Sample B-2 at 22 to 25 feet
pH - 7.9
Soluble Sulfate Content - <0.005% (negligible sulfate attack per UBC, 1994)
Minimum Resistivity - 7,700 ohm-cm (low corrosion potential)
Ch1oride Concentration - 500 ppm = 0.05% (moderate corrosion potential)
-.5-
4930489-013
CONCLUSIONS AND RECOMMENDATIONS
It is our opinion, the site is suitable to receive the proposed improvements provided the results of this
report, project plans, and manufacturer's specifications are adhered to.
Hidden Valley Road Undercrossing
The results of the geotechnical testing obtained for the Hidden Valley Road undercrossing are not
within the acceptable range specified by the manufacturer nor the Caltrans Highway Design Manual.
Accordingly, we recommend that an import source be used to backfill this undercrossing. The soils
within 5 feet of the bottom of the proposed footings and sides of the proposed undercrossing should
be removed and replaced with an import source. This should include removal of the colluvial soils
at the eastern end of the tunnel. The import source should be tested and approved by the geotechnical
consultant prior to construction. The import soils should have an expansion index less than 50 (per
UBC 18-2), have a pH from 5.5 to 8.5, have no sizes greater than 3 inches in maximum size, and
have a minimum resistivity greater than 1,500 ohms-cm. Import backfill soils should be compacted
to a minimum relative compaction of 95 percent (per ASTM D1557-91). It is our opinion that a
source of suitable backfilled material can be obtained on site.
Due to the impermeable characteristics of the native soils in the Hidden Valley Road tunnel area and
the anticipated use of a granular, free draining material for backfill, we recommend that a subdrain
be installed at the bottom of the tunnel excavation (below the invert of the pipe). The subdrain should
consist of a 4-inch diameter, Schedule 40 perforated pipe, encased in a minimum of 3-cubic foot of
clean 3/4-inch gravel, wrapped in Mirafi 140N geofabric or equivalent. The subdrain should daylight
out at the east end (lower end) below the tunnel.
Cannon Road Undercrossing
The results of the geotechnical testing obtained for the Cannon Road Undercrossing are within
acceptable range for backfill soils as stated in the brochure provided by the manufacturer of the
Aluminum Structural Plate (Contech, 1991) and the Caltrans Highway Design Manual. We
recommend, however, that the manufacturer review, the results of this testing to verify that the
chemical characteristics are within acceptable ranges. We also recommend that the manufacturer
review the chloride test results to evaluate if. the undercrossing needs a protective coating due to the
corrosive chloride environment.
For backfill of the Cannon Road undercrossing, the onsite granular soils may be utilized. All backfill
on the sides and within 2 feet of the top of pipe should be compacted to a minimum of 95 percent
(per ASTM D1557-91). Backfill adjacent to the structure should be compacted with lightweight
compaction equipment. All backfill should be placed above the optimum moisture content of the soil.
Soil placed from finish grade to within 2 feet of the top of pipe should be compacted to 90 percent
as should the pipe bedding area (see Figure 4, Backfill Detail). Backfill soils should be tested to
verify conformance with the manufacturer's specifications regarding chemical characteristics.
-6-
4930489-013
General Recommendations
If utility trenches are proposed over the top of the arch, we recommend that the trenches be backfihled
with lightweight hand operated compaction equipment (i.e. wacker) within 5 feet of the top of the
arch.
For design purposes, a soil-bearing value of 3,000 pounds per square foot may be utilized assuming
1/2-inch of settlement for footings at least 12 inches below tunnel invert level.
Some zones of relative cohesionless soils may be encountered during excavation. Therefore, the
stability of temporary slope should be evaluated during construction by the geotechnical consultant.
All slopes should be constructed in accordance with OSHA guidelines. In general, we recommend
that the excavation be laid back at an inclination of no steeper than 1:1.
Representatives of Contech stated that an equivalent aluminum corrosion rate of 0.5 mil per year may
be utilized (Army Corps of Engineers Study) for non-corrosive soils. This is roughly equivalent to
a time to perforation of 250 years for an aluminum thickness of 0.125 inches.
Approximately 2 feet of backfill is to be placed at the inside base of the undercrossing to provide a
pavement subgrade. The backfill soils should consist of granular soils with a very low to low
expansion potential (a less than 50 per UBC .18-2). In order to avoid an accumulation of water, we
recommend a subdrain be installed at the low point of the structure. The subdrain should consist of
a minimum of 1-cubic foot of clean 3/4-inch gravel wrapped in Mirafi 140N geofabric or equivalent
and outlet into a stonndrain or some other collective drainage system. As an alternative, a linear
slotted drain may be used at both entrances to the tunnel to intercept surface water provided all tunnel
joints are waterproof.
Pursuant to our investigation for previous undercrossings (Cannon Road and Armada Drive), the City
of Carlsbad expressed concern over the deflection of the arch(s) that may occur as part of site
construction. Therefore, we recommend the implementation of a monitoring program during site
construction.. This should include monitoring during construction to verify that the observed
deflections are within 2 percent of the deflections in accordance with ASTM D798-88 (shape control).
Duringinstallation, we recommend that the contractor implement a deflection monitoring program that
can be monitored continuously throughout the construction process by the contractor, civil and
geotechnical engineer and representative of the City of Carlsbad. In addition, the top of the arch
should be surveyed at various locations by the project civil engineer prior to and during backfilling
operations.
All backfill operations shall be performed to comply with the relative compaction recommendations
stated in Figures 4 and 5.
After backfill operations are complete and prior to installation of utilities above the arch, we
recommend that load testing of the arch be performed. The arch should be loaded to design loading
(H-20) and monitored for deflection by the City inspector, civil and geotechnical engineers. The civil
engineer will provide tolerable limits for deflection of the proposed utilities on the project plans.
Should these deflections be exceeded, additional recommendations to protect the proposed utilities will
-7-
0
4930489-013
be warranted. If measured deflections are within acceptable tolerances, installation of the proposed
utilities may proceed after written approval is received.
It may also be desirable to design all construction seams as watertight joints to minimize the potential
for future seepage-related problems.
During consction'of the undercrossing, continuous observation and testing of the backfill process
should be performed. In addition, prior to backfill, the chemical characteristics of the proposed
backfill soils should be tested prior to use to assure conformance with the project specifications and
the recommendations provided herein.
If you have any questions regarding our report, please contact this office. We appreciate this opportunity
to be of service.
Respectfully submitted,
LEIGHTON AND ASSOCIATES,
9 (Ex
co 0 0 Z Jose eG. Franzone, RC 9 No. 39 In Michael R. Stewart~ G 1349* (Exp. 12/31/97)
ector of Engineering cc Z Directory of Geology
SCB/JGFIMRS/jss
Attachments: Figure 1 - Site Location Map
Figure 2 - Boring Location Map
Figure 3 - Boring Location Map
Figure 4 - Typical Backfill Detail, Cannon Road Undercrossing
Figure 5 - Typical Backfill Detail, Hidden Valley Undercrossing :. Appendix A - References ..
Appendix B - Boring Logs
ED G4,04
Distribution: (2) Addressee .8 0
(2) Hunsaker and Associates Q:
Attention: Mr. Jeff Mitchell No. 349
CERTIFIED
ENGINEERING
LP ~A GEOLOGIST
OF CA
-8-
U
---
-
I - -
I
J
I 4 hfti1
-
MEN W-41 a N~Wm A I' I!SJI?
A
LEGEND I
B-2
Approximate boring location
TD2T with total depth indicated
! SR.00KS 18x1e,#
eR.ATc' fl4LT
I /.8
AR.Nco OR. EQUAL
SWTTE.D DRIJ
BORING LOCATION MAP
Golf Cart Undercrossings
Hidden Valley Road and Cannon Road
Carlsbad, California
Project No. _4930489-013 •
Scale • 4 0 I
Engr IGeol JGFIMRS II Ej_J Drafted By KAM 104588 •
flsltA •: •. tin 9
q•i
Pedestrian Underpass
L 43+00 Cannon Road
H.
XMCO OK EQUAL
SLOTTED 1KAt
1609
1!
docs is 15
KATe.D INLET
••-
'•- I.
1Ior,cc Z
TO DA1Lk44T j
H :
Project No. 4930489-013
Scie 1'40'
Enar.IGeoL JGF/MRS
Drafted By KAM 1045 W9
- Date 12796 Fi9Ize No.3
See Figure No. 2 for Legend,
BORING LOCATION MAP
Golf Cart Undercrossings;
Hidden Valley. Road and Cannon Road
Carlsbad, California
I
RR BACKFILL AREA --ALUMINUM STRUCTURAL PLA1E PIPE ARCH
960/0 MIN. Elm RELATIVE RELATIVE
1:1 TEMPORARY
CUT
SUBDRAIN
(SE TX11
NATIVE SOIL OR I- C NEUTRAL SAND BACKFILL
cOMPPCTEDFLL \ BEDDING AREA MIN.
SO% R.C.
AREATOBEJETTEDWTTH SELECT IAL MATERIAL SHALL BE APPROVED BY SOILS ENCHNEER PRIOR TO JETTiNG I
Project No. 4930489-013
- TYPICAL BACKFILL DETAIL Scale No scale II
Canyon Road Undercrosszng Engr/Geol JGF/MRS
Drafted By KAM 1042 889
Date 1-23-96 Figure No. 4
_
NATIVE SOIL UNACCEPTABLE FOR
USE AS BACKFILL IMPORT SOURCE 1___— RULAR BACKFILL AREA
TO BE APPROVED ByOEOT4ICA1. t AT 90% MIN. R.
CONSULTANT PRIOR TO BKFLL.-ALUMINUM STRUCTURAL PLATE PIPE ARCH
96% MN. 96% MN.
RELATIVE RELATIVE
-,
6'O
SUBDRAIN 1•4"
(SEE TCT
4
6'- 1" NEUTRAL SAND BACKFILL
14 90%MIN.
2% Pt
- 4" DIAMETER, SCHEDULE 40, PERFORATED PVC
[J
AREA TO BE JETTED WITH SELECT MATERIAL WITH 3 CUBIC FEET OF CRUSHED AGGREGATE
MATERIAL SHALL BE APPROVED BY SOILS PER FOOT WRAPPED IN MIRAPI I40N OR EQUIVALENT,
ENGINEER PRIOR TO JETTING DISCHARGE TOASUITABLE OUTLET.
Project No. 4930489-013
TYPICAL BACKFILL DETAIL Scale No scale
Engr~
U
FMRS ; Hidden Valley Road Undercrossing 1042 889
Date 1-23-96 Figure No. 5
..&. - . . A-i
4930489-013
APPENDIX A
California, Department of Transportation, 1990, Highway Design Manual, dated July 1, 1990.
Contech, 1991, Construction Products, Inc., 1991, Aluminum Structural Plate.
Hart, E.W., 1992, Fault-Rupture Hazard Zones in California, Alquist-Pnolo Special Studies Zones
Act of 1972 with Index to Special Study Zones Maps: Department of Conversation,
Division of Mines and Geology, Special Publication 42.
International Conference of Building Officials, .1994, Uniform Building Code.
Leighton and Associates, Inc., 1995a, Proposed Undercrossing, Cannon Road and Armada Drive,
Carlsbad Ranch, Phase I, Carlsbad, California, Project No. 4930489-09, dated June 13,
1995.
1995b, Geotechnical Investigation, Proposed Golf Cart Uñdercrossing, Cannon Road,
Carlsbad, California, Project No. 4930489-09, dated April 26, 1995.
1993, Preliminary Geotechnical Investigation, Units I and II (Lots 1 through 7), Carlsbad
Ranch Phase I, Carlsbad, California, Project No. 4930489-01, dated July 22, 1993.
,1992, City of Carlsbad Geotechnical Hazards Analysis and Mapping Study, 84 Sheets, dated
November, 1992.
1991, Supplemental Geotechnical Evaluation, Proposed College Business Park, Carlsbad
1 . . Tract 85-17, Carlsbad, California, Project No. 8841363-04, dated January 16, 1991 revised
j September 24, 1991.
,No Date, Waterproofing of Cannon Road and Armada Drive Undercrossing, Carlsbad Ranch,
Carlsbad, California, Project No. 4930489-008.
Weber, 1982, Recent Slope Failures, Ancient Landslides and Relation Geology of the North-Central
J
. Coastal Area, San Diego County, California, California Division of Mines and Geology,
Open File Report 82-12, LA.
I
GEOTECHNICAL BORING LOG KEY
Date Sheet 1 of 1
Project KEY TO BORING LOG GRAPHICS Project No.
Drilling Co. Type of Rig
Hole Diameter Drive Weight Drop in.
Elevation Top of Hole +1- ft. Ref. or Datum
cc 0
>
+.
CL CO •o.o
. .0
4d..J
.,-
0 Z
!
E
30
o
00Q. L .
c'.. 0
"
_W
C.'
—d U
:
w
GEOTECHNICAL DESCRIPTION
Logged By
Sampled By
0
—
-
- CL Inorganic clay of low to medium plasticity; gravelly clay; sandy clay; silty clay; lean
clay
CH Inorganic clay of high plasticity; fat clay
OL-OH Organic clay, silt or silty clay-clayey silt mixtures
ML Inorganic silt; very fine sand; silty or clayey fine sand; clayey silt with low plasticity
MH Inorganic silt; diatomaceous fine sandy or silty soils; elastic silt 5—
• CL-ML Low plasticity clay to silt mixture
ML-SM Sandy silt to silty sand mixture
CL-SC Sandy clay to clayey sand mixture
: SC-SM Clayey sand to silty sand mixture •
10—
SW Well graded sand; gravelly sand, little or no fines
SP Poorly graded sand; gravelly sand, little or no fines
.1: SM Silty sand; poorly graded sand-silt mixture
SC Clayey sand; poorly graded sand-clay mixture
GW Well graded gravel; gravel-sand mixture, little or no fines
GP Poorly graded gravel; gravel-sand mixture, little or no fines 15—
sz
GM Silty gravel; gravel-sand-silt mixture
GC Clayey gravel; gravel-sand-clay mixture
Sandstone
Siltstone
20—a
Claystone
0-049. Breccia (angular gravel and cobbles or matrix-supported conglomerate)
Conglomerate (rounded gravel and cobble, clast-supported)
Igneous granitic or granitic type rock
Metavolcanic or metamorphic rock N 1..
I 25
III •-. II
I Artificial or man-made fill
Asphaltic concrete
Portland Cement Concrete
J
505A(11/77) LEIGHTON & ASSOCIATES
GEOTECHNICAL BORING LOG B-i
Date 1-7-97 Sheet 1 of 2 Project Carltas Company/Golf Cart Undercrossing, Hidden Valley Road Project No. 4930489-013 Drilling Co. Barges Drilling Service Type of Rig Hollow-Stemg Hole Diameter 8 in. Drive Weight 140 pounds Drop 30 in. Elevation Top of Hole +/- 188 ft. Ref. or Datum Mean Sea Level
!- °-E M t
GEOTECHNICAL DESCRIPTION
Logged By SCB
Sampled By SCB
0-7 SM fILL.
-. . . @ 0'-2': Gray-brown, damp, medium dense, silty SAND; driller reports hard drilling at 3 feet
SM TERRACE DEPOSITS/SANTIAGO FORMATION 185 -
0 : @ 2': Gray-brown, damp, very dense clayey SAND
180 SANTIAGO FORMATION
@ 7': Gray-brown to pale-gray, damp, very dense, silty SAND with clay binder
10— 1 1 64/6 107.7 20.6 ML @ 10': Pale gray, damp, very stiff, fine sandy clayey SILTSTONE with black
manganese-type staining
175
15-
170 - 0
20-
- 2 65!3 124.3 10.6 @ 22': Pale gray to light brown, damp, very stiff, massive fine sandy to clayey 165 0 SII.TSTONE
S Bag-3 13.8 @ 25': Pale gray, damp, very dense, slightly silty SANDSTONE
SM
160 .
505A(11/77) LEIGHTON & ASSOCIATES
GEOTECHNICAL BORING LOG B-i
Date 1-7-97 Sheet 2 of 2
Project Caritas Company/Golf Cart Undercrossing, Hidden Valley Road Project No. 4930489-013
Drilling Co. Barges Drilling Service Type of Rig Hollow-Stem Auger
Hole Diameter 8 in. Drive Weight 140 pounds Drop 30 in.
P1vation Ton of Hole +1- 188 ft. Ref. or Datum Mean Sea Level
L GEOTECHNICAL DESCRIPTION
IL 0
.
110 IM 0 !' F
. Z .
.go ' Logged By SCB
W ° o Sampled By SCB
30— 4 113.5 8.0 SM @ 30': Same as at 25 feet
155-
35—'
150
40 \@ 40': Same as at 25 feet
Total Depth = 40 Feet
- No Ground Water Encountered at Time of Drilling
-
Hole Backfilled with Soil Cuttings on January 7. 19917
145-
45'
140
50-
135
55-
130
505A(11/77) LEIGHTON & ASSOCIATES
GEOTECHNICAL BORING LOG B-2
Date 1-8-97 Sheet 1 of 1
Project Carltas Company/Golf Cart Undercrossing, Cannon Road Project No. 4930489-013
Drilling Co. Barges Drilling Service Type of Rig Hollow-Stem Agç
Hole Diameter 8 in. Drive Weight 140 pounds Drop 30 in.
Elevation Top of Hole +1- 178 ft. Ref. or Datum Mean Sea Level
GEOTECHNICAL DESCRIPTION h h. 12
Z ' : Logged By SCB W IL
U Sampled By SCB
SM TERRACE DEPOSITS
- : @ 0'-15': Orangebrown, damp, medium dense to dense silty SAND
175
5.
170 -
10 1 50/4" 111.4 9.7 @ 10': Orange-brown, damp, very dense, medium to coarse grained silty SAND
165
@ 15': Pale gray, moist, dense silty clayey SAND
160
20—
-
2 96/9" 98.4 4.6 SW/SP @ 22': Pale gray, damp, very dense, poorly graded coarse-grained SAND
155-
2.5— Bag-3 4.2
- 22'-2
- - :•.:
- \@ 27': Practical refusal encountered on cobble/rock rial 0
-
150 -
0 . Total Depth = 27 Feet
No Ground Water Encountered at Time of Drilling
- Hole Backfilled on January 8, 1997 with Soil Cuttings
505A(11/77) .-. LEIGHTON & ASSOCIATES
1;
00•0., •j2
4930489-013
APPENDIX C
Laboratory Testing Procedures and Test Results
Expansion Index Tests: The expansion potential of selected materials was evaluated by the Expansion
Index Test, U.B.C. Standard No. 18-2. Specimens are molded under a given compactive energy to
approximately the optimum moisture content and approximately 50 percent saturation or approximately
90 percent relative compaction. The prepared 1-inch thick by 4-inch diameter specimens are loaded to
an equivalent 144 psf surcharge and are inundated with tap Water until volumetric equilibrium is reached.
The results of these tests are presented in the table below:
Compacted Dry Expansion Expansion
Sample Location Sample Description Density (pci) Index Potential
B @ 22' - 25' Fine sandy silt with clay 106.7 103 High
B2 @ 22'-- 25' Well graded sand 116.0 0 Very Low
.• ,•
• •• •