HomeMy WebLinkAboutAMEND 2017-0020; GRAND PACIFIC PALISADES HOTEL EXPANSION; STRUCTURAL CALCULATIONS FOR RETAINING WALL; 2018-09-10Re~rJ. CcfJ
B\V E STRUCTURAL• CIVIL• SURVEY• LAND PLANNING 1,~(l t
9449 Balboa Avenue, Suite 270 • San Diego, CA 92123
Phone (619) 299-5550 • Fax (619) 299-9934
www.bwesd.com
ENGINEER: J. Morgan
DATE: September 10, 2018
PROJECT NUMBER: 12215A.2.00
OCT 2 2 2nm
STRUCTURAL CALCULATIONS
FOR
HILTON TAPESTRY
S1TE-wAtt:S (Re t AI Ni NG ~,A t..L S)
AMEND2017-0020/GR2018-0028/DWG356-7C
ltt<AN o f,,t,.C,\ Ft c.. "f'A-\..\ GA-Qe S \-IOiEL B-X PAN s I of..l
5803 ARMADA DRIVE
CARLSBAD, CALIFORNIA 92008
LA.ND ocVL:LOPMENT
Prepared for
GRAND PACIFIC RESORTS, INC.
5900 PASTEUR CT, #200
Use menu Item Settings > Printing & Title Block
to set these five lines of Information
for your program.
Title Hllto~ PL Site Wall
Job# : Dsgnr: JM
Description ....
This Wall in File: A:\PROJECnGPR\13127A.1 Hilton Tapastry Hotel Expansion\CALCS\site wall.RPX
Page : 1
Date: 20 AUG 2018
RetalnPro (c) 1987-2016, Build 11.17.03.17 License: KW~066430 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To : BURKETT AND WONG ENGINEERS
I Criteria • I Soil Data •
Retained Height
Wall height above soil
Slope Behind Wall
Height of Soil over Toe
Water height over heel
4.00 ft
3.00ft
0.00
12.00 in
0.0ft
Allow Soil Bearing 3,000.0 psf
Equivalent Fluid Pressure Method
Active Heel Pressure 55.0 psf/ft
Passive Pressure
Soil Density, Heel
Soil Density, Toe
FootingUSoil Friction
Soil height to ignore
for passive pressure
300.0 psf/ft
= 110.00 pcf
0.00 pcf
= 0.350
0.00 in
,I S~u•r•c-ha•r•g•e•L•o•ad.s _____ _.1 I Lateral Load Applied to Stem • I Adjacent Footing Load
Surcharge Over Heel = 0.0 psf
Used To Resist Sliding & Overturning
Surcharge Over Toe 0.0
Used for Sliding & Overturning
I Axial Load Applied to Stem I
Axial Dead Load
Axial Live Load
Axial Load Eccentricity
I Design Summary
0.0 lbs
0.0lbs
0.0 in
• Wall Stablllty Ratios
Overturning
Sliding =
1.68 OK
1.75 OK
Total Bearing Load
... resultant ecc. =
1,728 lbs
9.57 in
Soil Pressure@ Toe = 2,544 psf OK
Soil Pressure @ Heel = 0 psf OK
Allowable 3,000 psf
Soil Pressure Less Than Allowable
ACI Factored@ Toe 3,562 psf
ACI Factored@ Heel 0 psf
Footing Shear@ Toe 0.0 psi OK
Footing Shear@ Heel = 5.9 psi OK
Allowable 75.0 psi
Sliding Cales
Lateral Sliding Force =
less 100% Passive Force= -
less 100% Friction Force =
Added Force Req'd
... .for 1.5 Stability
687.5 lbs
600.0 lbs
604.7 lbs
0.0 lbs OK
0.0 lbs OK
Lateral Load
... Height to Top
... Height to Bottom
0.0 #/ft
0.00 ft
0.00 ft
Adjacent Footing Load
Footing Width
Eccentricity
Load Type = Wind (W)
(Service Level)
Wall to Ftg CL Dist
Footing Type
Base Above/Below Soil
Wind on Exposed Stem =
(Service Level)
Service Level
Strength Level
Shear ..... Allowable
Anet (Masonry)
Rebar Depth 'd'
o.o psf
= Masonry
ASD
8.00
= # 4
= 24.00
= Edge
at Back of Wall
Poisson's Ratio
0.719
lbs=
lbs=
ft-#=
ft-#=
440.0
586.7
816.1
psi = 4.8
psi=
psi = 52.1
in2 = 91 .50
in= 5.25
=
= • 0.0 lbs
0.00 ft
0.00in
0.00 ft
Line Load
0.0 ft
0.300
Masonry Data -------------------------
Vertical component of active lateral soil pressure IS
NOT considered in the calculation of soil bearing
Load Factors -------------
Building Code
Dead Load
Live Load
Earth,H
Wind,W
Seismic, E
CBC 2016,ACI
1.200
1.600
1.600
1.000
1.000
rm
Fs
Solid Grouting
Modular Ratio 'n'
Wall Weight
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
psi= 2,000
psi= 20,000
Yes
16.11
psf = 78.0
= 1.000
in= 7.60
Medium Weight
ASD
Concrete Data -------------------------
fc
Fy
psi=
psi=
Use menu Item Settings > Printing & Title Block
to set these five llnes of Information
Title HlltOI\ PL Site Wall
Job # : Dsgnr: JM
Page : 2
Date: 20 AUG 2018
for your program. Description ....
This Wall in File: A:IPROJECnGPR\13127A.1 Hilton Tapastry Hotel Expansion\CALCS\site wall.RPX'
RetalnPro (e) 1987-2016, Build 11.17.03.17
License : KW-06066430 License To : BURKETT AND WONG ENGINEERS
Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
I Footing Dimensions & Strengths •
Toe Width
Heel Width
Total Footing Width
Footing Thickness
Key Width
Key Depth
Key Distance from Toe
fc = 2,500 psi Fy =
Footing Concrete Density =
0.00 ft
2.50
2.50
12.00 in
12.00 in
0.00 in
2.00 ft
60,000 psi
150.00 pcf
0.0018 Min.As%
Cover@ Top 2.00 @ Btm.= 3.00 in
Footing Design Results
Toe
Factored Pressure = 3,562
Mu' : Upward = O
Mu' : Downward O
Mu: Design O
Actual 1-Way Shear = 0.00
Allow 1-Way Shear 0.00
Toe Reinforcing = None Spec'd
Heel Reinforcing = None Spec'd
Key Reinforcing None Spec'd
Other Acceptable Sizes & Spacings
• Heel
O psf
145 ft-#
1,406 ft-#
1,262 ft-#
5.89 psi
75.00 psi
Toe: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm
Heel: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm
Key: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 9.26 in
#5@ 14.35 in
#6@20.37 in
0.65 in2
0.26 in2 1ft
If two layers of horizontal bars:
#4@ 18.52 in
#5@28.70 in
#6@40.74 in
Summa of Overturnin & Resistin Forces & Moments
..... OVERTURNING ..... . .... RESISTING .....
Force Distance Moment Force Distance
Item lbs ft ft-# lbs ft
Heel Active Pressure 687.5 1.67 1,145.8 Soil Over Heel 806.7 1.58
Surcharge over Heel Sloped Soil Over Heel
Surcharge Over Toe = Surcharge Over Heel
Adjacent Footing Load Adjacent Footing Load
Added Lateral Load = Axial Dead Load on Stem =
Load @ Stem Above Soil = • Axial Live Load on Stem
Soil Over Toe =
Surcharge Over Toe =
Total 687.5 O.T.M. 1,145.8 Stem Weight(s) 546.0 0.33
Earth @ Stem Transitions=
Footing Weight = 375.0 1.25
Resisting/Overturning Ratio 1.68 Key Weight 2.50
Vertical Loads used for Soil Pressure = 1,727.7 lbs Vert. Component =
Moment
ft-#
1,277.2
182.0
468.8
Total= 1,727.7 lbs R.M.= 1,928.0
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
I Tilt I
• Axial live load NOT included in total displayed( or used for overturning
resistance, but is included for soil pressure ca culation.
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus
Horizontal Dell@ Top of Wall (approximate only)
250.0 pci
0.198 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
Use menu item Settings > Printing & Title Block
to set these five lines of information
for your program.
Tille Hiltol\ PL Site Wall
Job # : Dsgnr: JM
Description ....
This Wall in File: A:\PROJECT\GPR\13127A.1 Hilton Tapastry Hotel Expansion\CALCS\site wall.RPX
Page : 1
Date: 20 AUG 2018
RetalnPro (c) 1987-2016, Build 11.17.03.17 License: KW-06056430 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To : BURKETT AND WONG ENGINEERS
I Criteria • I Soil Data •
Retained Height
Wall height above soil
Slope Behind Wall
Height of Soil over Toe =
Water height over heel
5.00 ft
2.00 ft
0.00
12.00 in
0.0 ft
Allow Soil Bearing = 3,000.0 psf
Equivalent Fluid Pressure Method
Active Heel Pressure = 55.0 psf/ft
Passive Pressure
Soil Density, Heel
Soil Density, Toe
FootingllSoil Friction
Soil height to ignore
for passive pressure
300. 0 ps f/ft
= 110.00 pcf
0.00 pcf
= 0.350
0.00 in
I '-i s.u.r.c.ha•r•g•e•L•o.ad_s _____ _.1 I Lateral Load Applied to Stem • I Adjacent Footing Load
Surcharge Over Heel 0.0 psf
Used To Resist Sliding & Overturning
Surcharge Over Toe 0.0
Used for Sliding & Overturning I Axial Load Applied to Stem I
Axial Dead Load
Axial Live Load
Axial Load Eccentricity
I Design Summary
Wall Stability Ratios
Overturning =
Sliding
Total Bearing Load =
... resultant ecc. =
0.0lbs
0.0 lbs
0.0 in
• 1.65 OK
1.62 OK
2,698 lbs
12.23 in
Soil Pressure@ Toe = 2,968 psf OK
Soil Pressure @ Heel = O psf OK
Allowable 3,000 psf
Soil Pressure Less Than Allowable
ACI Factored@Toe 4,155 psf
ACI Factored @ Heel = O psf
Footing Shear@ Toe =
Footing Shear@ Heel
Allowable
Sliding Cales
Lateral Sliding Force =
less 100% Passive Force = -
less 100% Friction Force =
Added Force Req'd
... .for 1.5 Stability
0.0 psi OK
4.8 psi OK
75.0 psi
1,161.9Ibs
937.5 lbs
944.3 lbs
0.0 lbs OK
0.0 lbs OK
Lateral Load
... Height to Top
... Height to Bottom
Load Type
Wind on Exposed Stem =
(Service Level)
Service Level
Strength Level
Shear ..... Ailowable
Anet (Masonry)
Rebar Depth 'd'
0.0 #/ft
0.00 ft
0.00 ft
Adjacent Footing Load
Footing Width
Eccentricity
Wind(YV)
(Service Level)
Wall to Fig CL Dist
Footing Type
Base Above/Below Soil
0.0 psf at Back of Wall
Poisson's Ratio
= Masonry
ASD
8.00
# 4
= 16.00
= Edge
lbs=
lbs=
ft-#=
ft-#=
psi=
psi=
psi=
in2=
in=
0.949
687.5
1,145.8
1,206.9
7.5
52.1
91.50
5.25
=
=
=
• 0.0 lbs
0.00 ft
0.00in
0.00 ft
Line Load
0.0 ft
0.300
Masonry Data -------------------------
Vertical component of active lateral soil pressure IS
considered in the calculation of soil bearing pressures.
Load Factors -------------
Building Code
Dead Load
Live Load
Earth,H
Wind,W
Seismic, E
CBC 2016,ACI
1.200
1.600
1.600
1.000
1.000
fm
Fs
Solid Grouting
Modular Ratio 'n'
Wall Weight
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
psi=
psi=
=
=
psf=
In=
=
2,000
20,000
Yes
16.11
78.0
1.000
7.60
Medium Weight
ASD
Concrete Data -------------------------
f c psi=
Fy psi=
Use menu Item Settings > Printing & Title Block
to set these five lines of lnfonnatlon
for your program.
Title Hllto" PL Site Wall
Job # : Dsgnr: JM
Description ....
This Wall in File: A:\PROJECnGPR\13127A.1 Hilton Tapastry Hotel Expansion\CALCS\site wall.RPX
Page : 2
Date: 20 AUG 2018
RetalnPro (c) 1987-2016, Build 11.17.03.17
License : KW-06066430 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To : BURKETT AND WONG ENGINEERS
I Footing Dimensions & Strengths •
Toe Width
Heel Width
Total Footing Width
Footing Thickness
KeyWidlh
Key Depth
Key Distance from Toe
0.00 ft
3.25
3.25
18.00 in
12.00 in
0.00 in
1.25 ft
fc = 2,500 psi Fy = 60,000 psi
150.00 pcf Footing Concrete Density
Min.As%
Cover@Top 2.00
= 0.0018
@ Btm.= 3.00 in
Footing Design Results
~
Factored Pressure = 4,155
Mu' : Upward 0
Mu' : Downward O
Mu: Design = O
Actual 1-Way Shear 0.00
Allow 1-Way Shear 0.00
Toe Reinforcing None Spec'd
Heel Reinforcing = None Spec'd
Key Reinforcing None Spec'd
Other Acceptable Sizes & Spacings
• Heel
O psf
582 ft-#
3,504 ft-#
2,922 ft-#
4.77 psi
75.00 psi
Toe: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm
Heel: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm
Key: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 6.17 in
#5@ 9.57 in
#6@ 13.58 in
1.26 in2
0.39 in2 1ft
If two layers of horizontal bars:
#4@ 12.35 in
#5@ 19.14 in
#6@ 27.16 in
Summa of Overturnin & Resistin Forces & Moments
. .... RESISTING ..... ..... OVERTURNING ..... Force Distance Moment Force Distance Moment
Item lbs ft ft-#
Heel Active Pressure 1,161.9 2.17 2,517.4
Surcharge over Heel =
Surcharge Over Toe
Adjacent Footing Load =
Added Lateral Load
Load @ Stem Above Soil =
Total 1,161.9 O.T.M. 2,517.4
Resisting/Overturning Ratio
Vertical Loads used for Soil Pressure =
1.65
2,698.1 lbs
Soll Over Heel
Sloped Soil Over Heel
Surcharge Over Heel
Adjacent Footing Load =
Axial Dead Load on Stem =
• Axial Live Load on Stem
Soil Over Toe
Surcharge Over Toe
Stem Weight(s) =
Earth @ Stem Transitions=
Footing Weigh1 =
Key Weight
Vert. Component =
lbs ft ft-#
1,420.8 1.96 2,782.5
546.0 0.33 182.0
731.3 1.63 1,188.3
1.75
3.25
Total= 2,698.1 lbs R.M.= 4,152.7
Vertical component of active lateral soil pressure IS considered in the
calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS considered in the
calculation of Overturning Resistance.
I Tilt I
• Axial live load NOT Included in total displayed! or used for overturning
resistance, but is included for soil pressure ca culation.
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus
Horizontal Defl@ Top of Wall (approximate only)
250.0 pci
0.178 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
Use menu Item Settings > Printing & Title Block
to set these five lines of Information
for your program.
Title Hllto" Site Wall
Job# : Dsgnr: JM
Description ....
This Wall in File: A:\PROJECnGPR\13127A.1 Hilton Tapastry Hotel Expansion\CALCS\site wall.RPX
Page : 1
Date: 20 AUG 2018
RetalnPro (c) 1987-2016, Build 11.17.03.17
License: KW--06066430 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To : BURKETT AND WONG ENGINEERS
I Criteria • I Soil Data •
Retained Height = 4.00 ft
Wall height above soil = 3.00 ft
Slope Behind Wall = 0.00
Height of Soil over Toe = 12.00 in
Water height over heel 0.0 ft
Allow Soil Bearing = 3,000.0 psf
Equivalent Fluid Pressure Method
Active Heel Pressure = 55.0 psf/ft
Passive Pressure
Soil Density, Heel
Soil Density, Toe
FootingllSoil Friction
Soil height to ignore
for passive pressure
= 300.0 psf/ft
= 110.00 pcf
0.00 pcf
0.350
0.00 in
'-ii s.u.r.c.ha•r•g•e•L•o-ad_s _____ _.1 I Lateral Load Applied to Stem • Surcharge Over Heel = o.o psf
Used To Resist Sliding & Overturning
Surcharge Over Toe 0.0
Used for Sliding & Overturning I Axial Load Applied to Stem I
Axial Dead Load =
Axial Live Load
Axial Load Eccentricity
0.0 lbs
0.0 lbs
0.0 in
Lateral Load
... Height to Top
... Height to Bottom
Load Type
0.0 #/ft
0.00 ft
0.00 ft
= Wind /Y'I)
(Service Level)
Wind on Exposed Stem =
(Service Level)
0.0 psf
I Adjacent Footing Load • Adjacent Footing Load = 0.0lbs
Footing Width = 0.00 ft
Eccentricity 0.00in
Wall to Ftg CL Dist 0.00 ft
Footing Type Line Load
Base Above/Below Soil 0.0 ft at Back of Wall
Poisson's Ratio 0.300
I Design Summary
Wall Stablllty Ratios
Overturning • L.I s_te_m_c_o_n_s.tr.u.c.ti_o_n __ •• __:B:..:o:.::tt:=.om:.c:.... _____________ _
• -Stem OK
Sliding =
Total Bearing Load
... resultant ecc.
2.37 OK
1.62 OK
1,473 lbs
5.24 in
Soil Pressure@ Toe = 920 psf OK
Soil Pressure @ Heel = 62 psf OK
Allowable = 3,000 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe 1,288 psf
ACI Factored@ Heel 87 psf
Footing Shear@ Toe
Footing Shear @ Heel
Allowable =
Slldlng Cales
Lateral Sliding Force =
8.4 psi OK
3.8 psi OK
75.0 psi
less 100% Passive Force = -
less 100% Friction Force =
687.5 lbs
600.0 lbs
515.4 lbs
Added Force Req'd
.... for 1.5 Stability
0.0 lbs OK
0.0 lbs OK
Vertical component of active lateral soil pressure IS
NOT considered in the calculation of soil bearing
Load Factors ------------
Building Code
Dead Load
Live Load
Earth,H
Wind,W
Seismic, E
CBC 2016,ACI
1.200
1.600
1.600
1.000
1.000
Design Height Above Ftg ft= 0.00
Wall Material Above "Ht" Masonry
Design Method ASD
Thickness 8.00
Rebar Size = # 4
Rebar Spacing 24.00
Rebar Placed at Edge
Design Data -------------------------
fb/FB + fa/Fa
Total Force @ Section
Service Level
Strength Level
Moment. ... Actual
Service Level
Strength Level
Moment. .... Allowable
Service Level
Strength Level
Shear ..... Allowable
Anet (Masonry)
Rebar Depth 'd'
lbs=
lbs=
ft-#=
ft-#=
psi =
psi=
psi=
in2 =
in=
0.719
440.0
586.7
816.1
4.8
52.1
91 .50
5.25
Masonry Data -------------------------
fm
Fs
Solid Grouting
Modular Ratio 'n'
Wall Weight
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
psi=
psi=
=
=
psf=
=
in=
=
2,000
20,000
Yes
16.11
78.0
1.000
7.60
Medium Weight
ASD
Concrete Data -------------------------
fc psi =
Fy psi =
Use menu Item Settings > Printing & Title Block
to set these five lines of Information
Title Hllto1' Site Wall
Job# : Dsgnr: JM
Page : 2
Date: 20 AUG 2018
for your program. Description ....
This Wall in File: A:\PROJECnGPR\13127A.1 Hilton Tapastry Hotel Expansion\CALCS\site wall.RPX
RetalnPro (c) 1987-2016, Build 11.17.03.17
License : KW--06066430 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To : BURKETT AND WONG ENGINEERS
I Footing Dimensions & Strengths •
Toe Width
Heel Width
Total Footing Width
Footing Thickness
Key Width
Key Depth
Key Distance from Toe
1.25 ft
1.75
3.00
12.00 in
12.00 in
0.00 in
2.00 ft
fc = 2,500 psi Fy = 60,000 psi
150.00 pcf Footing Concrete Density
= 0.0018
Footing Design Results
Toe
Factored Pressure 1,288
Mu' : Upward 876
Mu' : Downward 309
Mu: Design = 567
Actual 1-Way Shear 8.35
Allow 1-Way Shear 75.00
Toe Reinforcing None Spec'd
Heel Reinforcing None Spec'd
Key Reinforcing = None Spec'd
Other Acceptable Sizes & Spacings
• Heel
87 psf
136 ft-#
543 ft-#
408 ft-#
3.84 psi
75.00 psi
Min.As%
Cover@ Top 2.00 @ Btm.= 3.00 in Toe: #4@ 9.26 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.78 in, #8@ 36.57 in, #9@ 46
Heel: Not req'd: Mu < phi•5•Iambda•sqrt(fc)"Sm
Key: Not req'd: Mu < phi•5•Iambda•sqrt(fc)"Sm
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 9.26 in
#5@ 14.35 in
#6@20.37 in
0.78 in2
0.26 in2 1ft
If two layers of horizontal bars:
#4@ 18.52 in
#5@28.70 in
#6@40.74 in
Summa of Overturnin & Resistin Forces & Moments
..... OVERTURNING ..... .. ... RESISTING .....
Force Distance Moment Force Distance
Item lbs ft ft-# lbs ft
Heel Active Pressure 687.5 1.67 1,145.8 Soil Over Heel = 476.7 2.46
Surcharge over Heel Sloped Soil Over Heel =
Surcharge Over Toe Surcharge Over Heel
Adjacent Footing Load Adjacent Footing Load =
Added Lateral Load = Axial Dead Load on Stem =
Load @ Stem Above Soil = • Axial Live Load on Stem
= Soil Over Toe 0.63
Surcharge Over Toe
Total 687.5 O.T.M. 1,145.8 Stem Weight(s) 546.0 1.58
Earth @ Stem Transitions=
= = Footing Weight = 450.0 1.50
Resisting/Overturning Ratio 2.37 Key Weight = 2.50
Vertical Loads used for Soil Pressure = 1,472.7 lbs Vert. Component
Moment
ft-#
1,171.8
884.5
675.0
Total= 1,472.7 lbs R.M.= 2,711.3
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
I Tilt I
• Axial live load NOT Included in total displayed1 or used for overturning
resistance, but is Included for soil pressure ca,culation.
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus
Horizontal Dell@ Top of Wall (approximate only)
250.0 pci
0.060 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe,
because the wall would then tend to rotate into the retained soil.
Use menu Item Settings > Printing & Title Block
to set these five lines of Information
for your program.
Title Hllto" Site Wall
Job# : Dsgnr: JM
Description ....
This Wall in File: A:\PROJECnGPR\13127A.1 Hilton Tapastry Hotel Expansion\CALCS\site wall.RPX
Page : 1
Date: 20 AUG 2018
RetalnPro (c) 1987-2016, Build 11.17.03.17
License: KW-06056430 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To : BURKETT AND WONG ENGINEERS
I Criteria • I Soil Data •
Retained Height 5.00 ft Allow Soil Bearing = 3,000.0 psf
wall height above soil 2_00 ft Equivalent Fluid Pressure Method
Slope Behind Wall 0.00
Height of Soil over Toe =
Water height over heel
12.00 in
0.0 ft
Active Heel Pressure 55.0 psf/ft
Passive Pressure
Soil Density, Heel
Soil Density, Toe
Footingl!Soil Friction
Soil height to ignore
for passive pressure
= 300.0 psf/ft
110.00 pcf
o.oo pcf
= 0.350
0.00 in
71 S~u•r•c•h-ar•g~e•L•o•a•d•s-----_.l I Lateral Load Applied to Stem I I Adjacent Footing Load
Surcharge Over Heel = o.o psf
Used To Resist Sliding & Overturning
Surcharge Over Toe 0.0
Used for Sliding & Overturning
I Axial Load Applied to Stem I
Axial Dead Load
Axial Live Load
Axial Load Eccentricity
0.0 lbs
0.0 lbs
0.0 in
Lateral Load
... Height to Top
... Height to Bottom
Load Type
Wind on Exposed Stem =
(Service Level)
0.0 #/ft Adjacent Footing Load
0.00 ft Footing Width
0.00 ft Eccentricity
Wind0N) Wall to Ftg CL Dist =
(Service Level) Footing Type
Base Above/Below Soil
0.0 psf at Back of Wall =
Poisson's Ratio =
0.0 lbs
0.00 ft
0.00in
0.00 ft
Line Load
0.0 ft
0.300
•
I Design Summary • '-,,S-te.m_c_o_n.s.tr.u.c.ti•o•n __ ... .......:.B;;..co:..:tt:..:o..:..:m,;.._ ______________ _
• -Stem OK
Wall Stablllty Ratios
Overturning
Sliding
Total Bearing Load
... resultant ecc.
2.20 OK
1.55 OK
2,462 lbs
8.23 in
Soll Pressure@ Toe 1,334 psf OK
Soil Pressure @ Heel O psf OK
Allowable = 3,000 psf
Soil Pressure Less Than Allowable
ACI Factored@ Toe = 1,868 psf
ACI Factored@ Heel = O psf
Footing Shear@ Toe
Footing Shear @ Heel =
Allowable
Slldlng Cales
Lateral Sliding Force
7.9 psi OK
5.3 psi OK
75.0 psi
less 100% Passive Force= -
less 100% Friction Force =
1,161 .9 lbs
937.5 lbs
861.8 lbs
Added Force Req'd
.... for 1.5 Stability
0.0 lbs OK
0.0 lbs OK
Vertical component of active lateral soil pressure IS
considered in the calculation of soil bearing pressures.
Load Factors -------------
Building Code
Dead Load
Live Load
Earth,H
Wind,W
Seismic, E
CBC 2016,ACI
1.200
1.600
1.600
1.000
1.000
Design Height Above Ftg ft= 0.00
Wall Material Above "Ht" Masonry
Design Method ASD
Thickness = 8.00
Rebar Size # 4
Rebar Spacing = 16.00
Rebar Placed at Edge
Design Data -------------------------
fb/FB + fa/Fa
Total Force @ Section
Service Level
Strength Level
Moment. ... Actual
Service Level
Strength Level
Moment. .... Allowable
Service Level
Strength Level
Shear ..... Allowable
Anet (Masonry)
Rebar Depth 'd'
lbs=
lbs=
ft-#=
ft-#=
psi=
psi=
psi=
in2 =
in=
0.949
687.5
1,145.8
1,206.9
7.5
52.1
91.50
5.25
Masonry Data -------------------------
fm
Fs
Solid Grouting
Modular Ratio 'n'
Wall Weight
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
psi=
psi=
=
=
psf=
=
in=
2,000
20,000
Yes
16.11
78.0
1.000
7.60
Medium Weight
ASD
Concrete Data -------------------------
fc psi=
Fy psi=
Use menu Item Settings > Printing & Tltle Block
to set these five llnes of Information
Tille Hllto" Site Wall
Job# : Dsgnr: JM
Page : 2
Date: 20 AUG 2018
for your program. Description ....
This Wall in File: A:IPROJECnGPR\13127A.1 Hilton Tapastry Hotel Expansion\CALCS\site wall.RPX
Ret.alnPro (c) 1987-2016, Build 11.17.03.17
License : KW-46066430 License To : BURKETT AND WONG ENGINEERS
Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
I Footing Dimensions & Strengths •
Toe Width
Heel Width
Total Footing Width
Footing Thickness
Key Width
Key Depth
Key Distance from Toe =
fc = 2,500 psi Fy =
Footing Concrete Density
1.25 ft
2.58
3.83
18.00 in
12.00 in
0.00 in
1.25 ft
60,000 psi
150.00 pcf
0.0018
Footing Design Results
12!!
Factored Pressure 1,868
Mu' : Upward 1,294
Mu' : Downward 398
Mu: Design = 897
Actual 1-Way Shear = 7.94
Allow 1-Way Shear 75.00
Toe Reinforcing None Spec'd
Heel Reinforcing = None Spec'd
Key Reinforcing None Spec'd
Other Acceptable Sizes & Spacings
• Heel
O psf
471 ft-#
2,005 ft-#
1,533 ft-#
5.30 psi
75.00 psi
Min. As%
Cover@Top 2.00 @ Btm.= 3.00 in Toe: #4@6.17 in, #5@9.57 in, #6@ 13.58 in, #7@ 18.52 in, #8@24.38 in, #9@ 30.
Heel: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm
Key: Not req'd: Mu < phi*5*Iambda*sqrt(fc)*Sm
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 6.17 in
#5@ 9.57 in
#6@ 13.58 in
1.49 in2
0.39 in2 /ft
If two layers of horizontal bars:
#4@ 12.35 in
#5@ 19.14 in
#6@27.16 in
Summa of Overturnin & Resistin Forces & Moments
..... OVERTURNING ..... .. ... RESISTING .....
Force Distance Moment Force Distance
Item lbs ft ft-# lbs ft
Heel Active Pressure = 1,161.9 2.17 2,517.4 Soil Over Heel 1,054.0 2.87
Surcharge over Heel Sloped Soil Over Heel
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load Axial Dead Load on Stem =
Load @ Stem Above Soil = • Axial Live Load on Stem =
= Soil Over Toe = 0.63
Surcharge Over Toe
Total 1,161.9 O.T.M. 2,517.4 Stem Weight(s) = 546.0 1.58
Earth@ Stem Transitions=
= = Footing Weight = 862.4 1.92
Resisting/Overturning Ratio = 2.20 Key Weight = 1.75
Vertical Loads used for Soil Pressure = 2,462.4 lbs Vert. Component 3.83
Moment
ft-#
3,030.0
864.5
1,652.8
Total c 2,462.4 lbs R.M.= 5,547.4
Vertical component of active lateral soil pressure IS considered in the
calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS considered in the
calculation of Overturning Resistance.
I Tilt I
• Axial live load NOT included in total displayed( or used for overturning
resistance, but is included for soil pressure ca culation.
Horizontal Deflection at Top of Wall due to settlement of soil
(Deflection due to wall bending not considered)
Soil Spring Reaction Modulus
Horizontal Defl @ Top of Wall (approximate only)
250.0 pci
0.068 in
The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe.
because the wall would then tend to rotate into the retained soil.