HomeMy WebLinkAboutCB 98-1978; LA COSTA DE MARBELLA; STRUCTURAL CALCULATIONS FOR THE BACK WALL; 1998-05-15STRUCTURAL CALCULATIONS FOR TIE BACK WALL AT LA COSTA DE MAR]3ELLA CLIENT: LA COSTA DE MARBELLA HOA LA COSTA AVENUE CARLSBAD, CA TABLE OF CONTENTS Introduction/Loads Vertical Span Horizontal Span Shear Anchor Bond Length Dywidag Multistrand Prestressing Steel Properties Table .000 I?a* 40 Sheet 1 Sheet 2-3 Sheet 4 Sheet 5 Sheet 6 Sheet 7 ( C040385 I 4 3L9i cmil /91Ji May 15, 1998 CR000233 Project Ref.: 961317-2 5575 MAGNATRON BLVD., SUITE H, SAN DIEGO, CALIFORNIA 92111 j] r1 rf1i ij1 [4J AUTHOR ANP CHECKED BY SHEET EET Lt.. OF 7 DATE ____ INEERIN STEMS RsJC. 61955412841 PROJECT____________________________ Ir_]TLT[rI 1'III[I p.sr T11 1::+jijII1Ii. _ZI1ITiI III - t7 I u I IET[JIrI1IIII.1L1I ii ....I :•:I•ifii.i4I•L 9540 WAPLES STREET • SUITE F • SAN DIEGO. CA 92121 ( Double Corrosion Protection DCP (Type C) - Corrosion protection for the anchor tendon can be 2 improved by extending the outer corrugated PE or PVC duct over the free stressing length. In this case, pregrouting of the anchor inside the plastic duct is not recommended because of difficulties which might be encountered during transportation and placing. Double Corrosion Protection DCP (Type D) The ideal protection for strand anchors is one in which the strand is totally and permanently pro- tected from the time of manufacture throughout its life. Such protection is provided by epoxy coating the individual strands both externally and internally Flo-bond Flo-fil® is a rugged, thermally bonded polymer coating that offers maximum corrosion protection, with a bond strength that exceeds that of bare strand. When two stage grouting is used, no additional corrosion protection is required even in applications where the free stressing length will remain ungrouted for an extended period of time. The Dywidag wedge anchor for epoxy coated strand bites through the coating into the strand, developing 100% of its nominal ultimate tensile strength. Corrosion protection provided by the epoxy is not compromised by the wedge. Although the cost of epoxy coated strand is higher than bare strand, the total cost of the installed anchor is reduced by eliminating the outer corru- gated plastic duct. This makes it possible to mini- mize the drill hole size, thereby reducing the cost of drilling and grouting. Double Corrosion Protection DCP (Type E) For anchors in which single stage grouting is desirable, the free stressing length of epoxy coat- ed strand anchors can be coated with a lubricat- ing grease and encased in a seamless extruded PE sheath. 3 Multistrand Prestressing Steel Properties - ASTM A416 Anchor Size Nominal Cross Section Area Nominal Weight (bare strand) Ultimate Strength (Fpu Aps) Prestressing Force 0.80 Fpu A 5 0.70 Fpu Aps 0.60 Fpu in2 mm pit kg/rn kips kN kips kN kips kN kips kN 3 -0.6 0.65 420 2.20 3.27 175.8 782 140.6 625 123.0 547 105.5 469 4 -0.6 0.87 560 3.00 4.46 234.4 1,043 187.5 834 164.1 730 140.6 626 5 -0.6 1.09 700 3.70 5.51 293.0 1,303 234.4 1.043 205.1 912 175.8 782 6 -0.6 1.30 840 4.40 6.55 351.6 1,564 281.3 1,251 246.1 1,095 211.0 938 7 -0.6 1.52 980 5.20 7.74 410.2 1,825 328.2 1,460 287.2 1,277 246.2 1.095 8 -0.6 1.74 1.120 5.90 8.78 468.8 2,085 375.0 1,668 1 328.1 1,460 281.3 1,251 9 -0.6 1.95 1.260 6.70 9.97 527.4 2,346 421.9 1,877 369.2 1,642 316.4 1.408 12 -0.6 2.60 1.680 8.90 13.24 703.2 3.128 562.6 2,503 492.3 2.190 422.0 1,877 15 -0.6 3.26 2.100 11.10 16.52 879.0 3.910 703.2 3,128 615.3 2,737 527.4 2.346 19 -0.6 4.12 2,660 14.10 20.98 1,113.4 4.953 890.7 3,962 779.4 3,467 668.0 2.972 27 -0.6 5.86 3,780 20.00 29.76 1,582.2 7,038 1,265.8 5,631 1,107.6 4.927 949.4 4,223 37 -0.6 8.03 5.180 27.40 40.78 2,168.2 9,645 1,734.6 7,716 1,517.8 6,751 1,301.0 5.787 48 -0.6 10.41 6,720 35.50 52.83 2,812.8 12,512 2,250.2 10,009 1,968.9 8,758 1,687.7 7,507 54 -0.6 11.72 7,560 39.90 59.38 3,164.4 14,076 2,531.5 11,261 2,215.1 9,853 1,898.6 8,446 61 -0.6 13.24 8,540 45.10 1 67.12 3,574.6 15,901 2,859.7 12,721 2,502.2 11,131 2,144.8 9,540 11