Loading...
HomeMy WebLinkAboutCDP 15-25; 4394 Yuki Lane; ADDENDUM 1 UPDATED GEOTECHNICAL REPORT ADDENDUM 2; 2016-01-29GJNEERING DESIGN GROUP c~::r:c•:.UJ [ , . .,__ •,y:.•;::,r'.! . .\~~;: .. ~:crw-~ Let.-,,; ·:.w~ rc:~ ~-c:;;·~r•. ·:1~ & n ~·.!tt;.:~~ c.~st=-·~:.:-. 2121 Montiel Road, San Marcos, California 92069 ·(7so) 839-7302 ·Fax: (760) 480-7477 • www.designgroupca.com Date: January 29, 2016 To: Re: Pacific Beach 2014, Ltd. c/o San Dieguito Development Attn: Ted Montag 11 06 Second St PMB 255 Encinitas, CA 92024 p: 760.635.7633 e: tedmontag3@msn.com JUN 1 5 2016 Proposed new residence to be located at Lot 2 Yuki Lane, Carlsbad, California Subject: Addendum No. 1 -Updated Geotechnical Report COP 15-25 -4394 Yuki Lane Ref: 1. , Proposed New Single Family Residence to be California," prepared by Engineering Design Group, dated We have provided the following addendum in response to the City of Carlsbad Comments. 1. In the area along the north side of the house where the paved walkway provides a 2.5 feet horizontal distance to the localized low spot for drainage we recommend the area maintain sufficient distance below finish floors, limit pervious surfaces and provide for sufficient drainage devices to not allow runoff to pond adjacent to new foundations and improvements. 2. Erosional rilling, surficial weathering are anticipated and the 18 inch debris fence should be constructed atop the proposed retaining wall at the toe of the 2:1 graded slope. The retaining wall shall be detailed with sufficient drainage facilities to not allow water to pond behind the wall. 3. As noted in Section 7.3.g, footings adjacent to slopes shall maintain a minimum horizontal setback of 10 feet in competent compacted material. We·anticipate footings will be deepened in areas where the proposed structure is located near the top of the slope. Deepening is anticipated to extend to approximately 4 -5 feet deep, depending on actual conditions in the field. Foundation excavations shall be inspected by a representative of Engineering Design Group prior to the placement of steel, form boards and removal of excavation equipment. NEW RESIDENCE 4934 Yuki Lane, carlsbad, California ENGINEERING DESIGN GROUP GEOTECHNICAL, CIVIL, STRUCTURAL CONSULTANTS Page No.1 Job No. 155513-1 4. Regarding general red lined comments on the BMP plan, we recommend the following: a. The bioretention area on Lot 2 is located near the existing retaining wall. We recommend for walls over three feet an unlined bioretention area be located a minimum of 5 horizontal feet from the top of the wall or the height of the wall, whichever is greater. Prior to the installation of an unlined bioretention area the functionality of backdrain system of a downstream wall shall be verified. If you have any questions with respect to this letter please do not hesitate to call our office. Respectfully Submitted, ENGINEERING DESIGN GROUP Steven Norris California GE #2590 NEW RESIDENCE 4934 Yuki Lane, Carlsbad, California ENGINEERING DESIGN GROUP GEOTECHNICAL, CIVIL, STRUCTURAL CONSULTANTS Page No.2 Job No. 155513-1 ENGli'\fEERING DESIGN GROUP --- 2121 Montiel Road, San Marcos, California 92069 • (760) 839-7302 • Fax: (760) 480-7477 • www.designgroupca.com Date: June 13, 2016 To: Re: Pacific Beach 2014, Ltd. c/o San Dieguito Development Attn: Ted Montag 1106 Second St PMB 255 Encinitas, CA 92024 p: 760.635.7633 e: tedmontag3@msn.com JUN l 5 2016 Proposed new residence to be located at Lot 2 Yuki Lane, Carlsbad, California Subject: Addendum No. 2 COP 15-25 -4394 Yuki Lane Ref: 1. Addendum No. 1 -Updated Geotechnical Report, prepared by Engineering Design Group, dated January 29, 2015. 2. "Updated Geotechnical Recommendations, Proposed New Single Family Residence to be located at Lot 2, Yuki Lane, Carlsbad, California," prepared by Engineering Design Group, dated September 3, 2015. At the request of the City of Carlsbad we provide the following recommendations with respect to the installation of pervious concrete driveways at the above referenced site. 1. Specific constraints and details of pervious concrete in driveway area should be per the specific manufacturer and pervious pavement industry standards and recommendations, including edge restraints, minimum bedding specifications, base and subgrade requirements, installation tolerances, drainage, etc. 2. As pervious concrete relates to the geotechnical aspects of the project we provide the following recommendations: NEW RESIDENCE a. We recommend subgrade be compacted to 95% minimum compaction in the area of new pervious concrete driveways. b. Where runoff and stormwater is directed over permeable pavement and water is anticipated to flow through into an aggregate base, sub-drains and/or underdrains to be installed. Construction detailing to be reviewed prior to installation. c. The specific recommendations of the pervious pavement manufacturer may supersede the recommendations herein. Specific manufacturer recommendations shall be included in any pervious concrete detailing. 4930 Yuki Lane, Carlsbad, California Page No.1 Job No. 155513-1 ENGINEERING DESIGN GROUP GEOTECHNICAL, CIVIL, STRUCTURAL CONSULTANTS d. All other recommendations regarding biofiltration, per References 1 & 2 above, shall be adhered. If you have any questions with respect to this addendum, please do not hesitate to call our office. Respectfully Submitted, ENGINEERING DESIGN GROUP Steven Norris California GE #2590 Erin Rist California RCE 65122 NEW RESIDENCE 4930 Yuki lane, Carlsbad, California ENGINEERING DESIGN GROUP GEOTECHNICAL, CIVIL, STRUCTURAL CONSULTANTS Page No.2 Job No. 155513-1