HomeMy WebLinkAboutCDP 15-45; Abdi Residence; Retaining Wall Calculations Abdi Residence 5623 Shore Dr Carlsbad CA 92008; 2017-09-12Title R.T4 No Seismic Cales Page: 2
Job#: . Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=4'TRW
This Wall in File: j:\jobs\2016 jobs\2016-068 -abdi drainage\reportslrw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
Bottom Stem
As (based on applied moment) :
(4/3) •As:
Vertical Reinforcing
0.0364 in2/ft
0.0485 in2/ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.960 in2
200bd/fy: 200(12)(8.1875)/60000:
0.0018bh: 0.0018(12)(10):
0.3275 in2/ft
0.216 in2/ft
Min Stem T&S Re inf Area per ft of stem Height : 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
Required Area : 0.216 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.2325 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.1092 in2/ft #6@ 22.00 in #6@ 44.00 in
I Footing Dimensions & Strengths •
Toe Width
Heel Width
Total Footing Width
=
=
=
1.04 ft
1.88
2.92
Footing Thickness = 14.00 in
Key Width 10.00 in
Key Depth = 0.00 in
Key Distance from Toe 1.00 ft
fc = 2,500 psi Fy = 60,000 psi
Footing Concrete Density = 150.00 pcf
Min. As % = 0.0018
Cover@ Top 2.00 @ Btm.= 3.00 in
Footing Design Results •
~ 11w
Factored Pressure 1,984 O psf
Mu': Upward 917 15 ft-#
Mu' : Downward = 228 513 ft-#
Mu: Design = 689 498 ft-#
Actual 1-Way Shear 1.69 6.19 psi
Allow 1-Way Shear = 40.00 40.00 psi
Toe Reinforcing = None Spec'd
Heel Reinforcing = None Spec'd
Key Reinforcing None Spec'd
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu< phi•5•1ambda•sqrt(fc)'Sm
Heel: Not req'd: Mu < phi•5•1ambda•sqrt(fc)'Sm
Key: Not req'd: Mu < phi•5•1ambda•sqrt(fc)'Sm
Min footing T&S reinf Area 0.88 in2
0.30 in2 1ft Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 7.94 in
#5@ 12.30 in
#6@ 17.46 in
If two layers of horizontal bars:
#4@ 15.87 in
#5@24.60 in
#6@34.92 in
Summa of Overturnin & Resistin Forces & Moments
Item
Heel Active Pressure
Surcharge over Heel
Surcharge Over Toe =
Adjacent Footing Load =
Added Lateral Load
Load @ Stem Above Soil =
=
Total
=
Resisting/Overturning Ratio
••••• OVERTURNING .••••
Force Distance Moment
lbs ft ft-#
640.7 1.72 1,103.4
56.0
8.67
6.92
696.7 O.T.M.
387.3
1,490.7
=
Vertical Loads used for Soil Pressure =
= 1.87
1,661.5 lbs
. .... RESISTING •.••.
Force Distance
lbs ft
Soil Over Heel 520.8 2.40
Sloped Soil Over Heel =
Surcharge Over Heel
Adjacent Footing Load =
Axial Dead Load on Stem=
* Axial Live Load on Stem
Soil Over Toe 130.2 0.52
Surcharge Over Toe =
Stem Weight(s) = 500.0 1.46
Earth @ Stem Transitions=
Footing Weigh! = 510.4 1.46
Key Weight = 1.42
Vert. Component
Total= 1,661.5 lbs R.M.=
Moment
ft-#
1,247.8
67.8
729.2
744.4
2,789.2
* Axial live load NOT included in total displayed! or used for overturning
resistance, but is included for soil pressure ca culation.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure JS NOT considered in
the calculation of Overturning Resistance.
Title R.T4 f'lo Seismic Cales Page : 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=4'TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reports\rw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #5 bar specified in this stem design segment=
Development length for #5 bar specified in this stem design segment=
Hooked embedment length into footing for #5 bar specified in this stem design segment=
As Provided =
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
23.40 in
18.00 in
10.50 in
0.2325 in2/ft
0.0485 in2/ft
--'
Title R.T4 $eismic Cales Page: 2
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=4'TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreports\Jw\2016-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
Bottom Stem
As (based on applied moment) :
(4/3) •As:
Vertical Reinforcing
0.0418 in2/ft
0.0557 in2/ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.960 in2
200bd/fy: 200(12)(8.1875)/60000:
0.0018bh: 0.0018(12)(10):
0.3275 in2/ft
0.216 in2/ft
Min Stem T&S Re inf Area per ft of stem Height : 0.240 in2/ft
Horizontal Reinforcing, Options :
One layer of: Two layers of:
Required Area : 0.216 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.2325 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.1092 in2/ft #6@ 22.00 in #6@ 44.00 in
I Footing Dimensions & Strengths I
Toe Width
Heel Width
Total Footing Width
Footing Thickness
Key Width
Key Depth
Key Distance from Toe
=
=
=
=
fc = 2,500 psi Fy =
Footing Concrete Density =
1.04 ft
1.88
2.92
14.00 in
10.00 in o.oo in
1.00 ft
60,000 psi
150.00 pcf
0.0018 Min.As%
Cover@Top 2.00 @ Btm.= 3.00 in
Footing Design Results •
:rim l:wtl
Factored Pressure 2,344 0 psf
Mu' : Upward 1,049 o ft-#
Mu' : Downward = 228 513 ft-#
Mu: Design = 821 512 ft-#
Actual 1-Way Shear 2.07 6.79 psi
Allow 1-Way Shear = 40.00 40.00 psi
Toe Reinforcing = None Spec'd
Heel Reinforcing None Spec'd
Key Reinforcing None Spec'd
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi"5"1ambda"sqrt(fc)"Sm
Heel: Not req'd: Mu < phi'"5"1ambda*sqrt(fc)*Sm
Key: Not req'd: Mu < phi"5"1ambda"sqrt(fc)"Sm
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 7.94 in
#5@ 12.30 in
#6@ 17.46 in
0.88 in2
0.30 in2 1ft
If two layers of horizontal bars:
#4@ 15.87 in
#5@24.60 in
#6@34.92 in
Summary of Overturning & Resisting Forces & Moments
..... OVERTURNING ..... • .... RESISTING .....
Force Distance Moment
Item lbs · ft ft-#
Heel Active Pressure 640.7 1.72 1,103.4 Soil Over Heel =
Surcharge over Heel =
Surcharge Over Toe
Adjacent Footing Load =
Added Lateral Load
Load @ Stem Above Soil = 56.0
Seismic Earth Load = 57.9
Total 754.5
Resisting/Overturning Ratio
Vertical Loads used for Soil Pressure=
8.67
6.92 387.3
3.44 199.3
O.T.M. 1,690.0
1.65
1,661.5 lbs
Sloped Soil Over Heel
Surcharge Over Heel
Adjacent Footing Load =
Axial Dead Load on Stem=
* Axial Live Load on Stem =
Soil Over Toe
Surcharge Over Toe
Stem Weight(s) =
Earth @ Stem Transitions=
Footing Weigh! =
Key Weight =
Vert. Component
Force Distance
lbs ft
520.8
130.2
500.0
510.4
2.40
0.52
1.46
1.46
1.42
Moment
ft-#
1,247.8
67.8
729.2
744.4
Total= 1,661.5 lbs R.M.= 2,789.2
If seismic is included, the OTM and sliding ratios be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
* Axial live toad NOT included in total displayed! or used for overturning resistance, but is included for soil pressure ca culation.
•
Title R.T4 ~eismic Cales Page: 4
Job# : Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=4'TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reportslrw\2016--68 abdi drainage.rpx
RetalnPro (c) 1987~2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #5 bar specified in this stem design segment:::
Development length for #5 bar specified in this stem design segment:::
Hooked embedment length into footing for #5 bar specified in this stem design segment:::
As Provided :::
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
23.40 in
18.00 in
10.50 in
0.2325 in21ft
0.0557 in2/ft
Title R.T6.J No Seismic Cales Page : 2
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=6.33.TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reportslrw\2016--68 abdi drainage.rpx
RetainPro {c) 1987-2017, Build 11.17.07.27
License : KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
Bottom Stem
As (based on applied moment) :
(4/3) •As:
Vertical Reinforcing
0.1228 in2/ft
0.1637 in2/ft
Horizontal Reinforcing
Min Stem T&S Rein! Area 1.519 in2
200bd/fy: 200(12)(7.625)/60000:
0.0018bh : 0.0018(12)(10) :
0.305 in2/ft Min Stem T&S Rein! Area per ft of stem Height: 0.240 in2/ft
0.216 in2/ft Horizontal Reinforcing Options :
One layer of: Two layers of:
Required Area : 0.216 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.33 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
I Footing Dimensions & Strengths I
Toe Width
Heel Width
Total Footing Width
Footing Thickness
=
=
=
Key Width =
Key Depth =
Key Distance from Toe =
fc = 2,500 psi Fy =
Footing Concrete Density
1.54 ft
2.38
3.92
16.00 in
10.00 in
8.00 in
1.54 ft
60,000 psi
150.00 pcf
0.0018 Min.As%
Cover@Top 2.00 @ Btm.= 3.00 in
Footing Design Results I
~ l::lw
Factored Pressure = 2,834 O psf
Mu': Upward = 2,797 45 ft-#
Mu': Downward 541 1,649 ft-#
Mu: Design 2,256 1,605 ft-#
Actual 1-Way Shear 6.27 11.53 psi
Allow 1-Way Shear 40.00 40.00 psi
Toe Reinforcing None Spec'd
Heel Reinforcing = None Spec'd
Key Reinforcing = # 6 @ 18.00 in
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi•s•1ambda•sqrt(fc)•sm
Heel: Not req'd: Mu < phi•5•1ambda•sqrt(fcrsm
Key: Not req'd: Mu < phi•5•1ambda"sqrt(fcrsm
Min footing T&S reinf Area 1.35 in2
0.35 in2 ,tt Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 6.94 in
#5@ 10.76 in
#6@ 15.28 in
If two layers of horizontal bars:
#4@ 13.89 in
#5@21.53 in
#6@30.56 in
Summa of Overturnin & Resistin Forces & Moments
••••• OVERTURNING ..... . .•.. RESISTING ..... Force Distance Moment Force Distance
Item lbs ft ft-# lbs ft
Heel Active Pressure = 1,409.4 2.55 3,600.3 Soil Over Heel 1,219.8 3.15
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load = Adjacent Footing Load =
Added Lateral Load 11.16 Axial Dead Load on Stem =
Load @ Stem Above Soil = 56.0 9.41 527.1 * Axial Live Load on Stem
Soil Over Toe = 192.7 0.77
Surcharge Over Toe =
Total 1,465.4 O.T.M. 4,127.5 Stem Weight(s) 791.3 1.96
Earth @ Stem Transitions=
= Footing Weight = 783.3 1.96
Resisting/Overturning Ratio 1.75 Key Weight = 83.3 1.96
Vertical Loads used for Soil Pressure = 3,070.5 lbs Vert. Component
Moment
ft-#
3,837.4
148.5
1,549.5
1,534.0
163.2
Total= 3,070.5 lbs R.M.= 7,232.7
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
* Axial live load NOT included in total displayed! or used for overturning resistance, but is included for soil pressure ca culation.
i
I
Title R.T6.~ No Seismic Cales Page : 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=6.33'TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016--68 abdi drainage.rpx
RetainPro {c) 1987-2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: Bottom
Stem Design Height: 0.00 fl above top of footing
Lap Splice length for #6 bar specified in this stem design segment=
Development length for #6 bar specified in this stem design segment=
Hooked embedment length into footing for #6 bar specified in this stem design segment=
As Provided =
As Required =
Code: CBC 2016,ACI 318-14,ACI 530-13
28.08 in
21.60 in
12.60 in
0.3300 in2/ft
0.1637 in2/ft
Title R.T6.J Seismic Cales Page: 2
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=6.33'TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016--68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
Bottom Stem
As (based on applied moment) :
(4/3) •As:
200bdify: 200(12)(7.625)/60000:
0.0018bh: 0.0018(12)(10):
Required Area :
Provided Area :
Maximum Area :
Vertical Reinforcing
0.1452 in2ift
0.1935 in2/ft
0.305 in2/ft
0.216 in2ift
0.216 in2/ft
0.33 in2/ft
1.0329 in2/ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 1.519 in2
Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 10.00 in #4@ 20.00 in
#5@ 15.50 in #5@ 31.00 in
#6@ 22.00 in #6@ 44.00 in
I Footing Dimensions & Strengths • Footing Design Results •
Toe Width
Heel Width
Total Footing Width
Footing Thickness
Key Width
=
=
=
Key Depth =
Key Distance from Toe =
fc = 2,500 psi Fy =
1.54 ft
2.38
3.92
16.00 in
10.00 in
8.00 in
1.54 ft
60,000 psi
150.00 pcf Footing Concrete Density
Min. As 0/o = 0.0018
Cover@Top 2.00 @ Btm.= 3.00 in
~ .l:lw
Factored Pressure = 3,648 0 psf
Mu' : Upward 3,390 0 ft-#
Mu' : Downward = 541 1,649 ft-#
Mu: Design = 2,849 1,649 ft-#
Actual 1-Way Shear = 8.24 12.73 psi
Allow 1-Way Shear 40.00 40.00 psi
Toe Reinforcing = None Spec'd
Heel Reinforcing = None Spec'd
Key Reinforcing = # 6 @ 18.00 in
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi,.5*lambda*sqrt(fc)*Sm
Heel: Not req'd: Mu < phi•5•1ambda•sqrt(fc)'Sm
Key: Not req'd: Mu < phi•5•1ambda•sqrt(fc)'Sm
Min footing T&S reinf Area 1.35 in2
Min footing T&S reinf Area per foot 0.35 in2 1ft
If one layer of horizontal bars: If two layers of horizontal bars:
#4@ 6.94 in #4@ 13.89 in
#5@ 10.76 in #5@21.53 in
#6@ 15.28 in #6@ 30.56 in
I Summary of Overturning & Resisting Forces & Moments •
..... OVERTURNING..... .. ... RESISTING .....
Force Distance Moment Force Distance Moment
Item lbs ft ft-# lbs ft ft-#
Heel Active Pressure = 1,409.4 2.55 3,600.3 Soil Over Heel = 1,219.8 3.15 3,837.4
Surcharge over Heel = Sloped Soil Over Heel =
Surcharge Over Toe = Surcharge Over Heel =
Adjacent Footing Load Adjacent Footing Load =
Added Lateral Load 11.16 Axial Dead Load on Stem=
Load @ Stem Above Soil =
Seismic Earth Load =
=
Total
Resisting/Overturning Ratio
56.0
135.7
1,601.2
Vertical Loads used for Soil Pressure=
9.41
5.11
527.1
693.4
O.T.M. 4,820.8
=
= 1.50
3,070.5 lbs
• Axial Live Load on Stem
Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s) =
Earth @ Stem Transitions=
Footing Weigh! =
Key Weight =
Vert. Component
192.7
791.3
783.3
83.3
0.77
1.96
1.96
1.96
148.5
1,549.5
1,534.0
163.2
Total= 3,070.5 lbs R.M.= 7,232.7
If seismic is included, the OTM and sliding ratios
be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
* Axial live load NOT included in total displayed! or used for overturning
resistance, but is included for soil pressure ca culation.
Title R.T6.~ Seismic Cales Page: 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H0 6.33'TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reportslrw\2016,-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056662 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #6 bar specified in this stem design segment=
Development length for #6 bar specified in this stem design segment=
Hooked embedment length into footing for #6 bar specified in this stem design segment=
As Provided =
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
28.08 in
21.60 in
12.60 in
0.3300 in2/ft
0.1935 in2/ft
Title R.T8.~ No Seismic Cales Page: 1
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=8.33'TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016--68 abdi drainage.rpx
RetalnPro (c) 1987~2017, Build 11.17.07.27
License : KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To · COFFEY ENGtNEERING INC
I Criteria • I Soil Data • Retained Height = 8.33 ft Allow Soil Bearing = 4,000.0 psf
Equivalent Fluid Pressure Method Wall height above soil = 3.50 ft Active Heel Pressure = 48.0 psi/ft -Slope Behind Wall = 0.00
Height of Soil over Toe = 12.00 in =
Water height over heel 0.0 ft Passive Pressure = 400.0 psi/ft = Soil Density, Heel = 125.00 pct
Soil Density, Toe = 125.00 pcf
Footingl[Soil Friction = 0.300 ~
Soil height to ignore ~ (r for passive pressure = 12.00 in
..,I S'!"u.r.c.h.ar.g'!"e•L•o•a•d•s-----.. • I Lateral Load Applied to Stern • I AdJacent Footing Load
Surcharge Over Heel 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
I Axial Load Applied to Stern I
Axial Dead Load =
Axial Live Load
Axial Load Eccentricity
I Design Summary
0.0 lbs
o.o lbs
0.0 in
• Wall Stability Ratios
Overturning
Sliding
=
=
1.79 OK
1.50 OK
Total Bearing Load
... resultant ecc. =
4,606 lbs
13.42 in
Soil Pressure@ Toe 2,292 psf OK
Soil Pressure @ Heel = O psf OK
Allowable 4,000 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe 3,209 psf
ACI Factored @ Heel = O psf
Footing Shear@ Toe = 13.8 psi OK
Footing Shear@ Heel 18.0 psi OK
Allowable 75.0 psi
Sliding Cales
Lateral Sliding Force
less 100% Passive Force =
less 70 % Friction Force =
Added Force Req'd =
.... for 1.5 Stability
2,297.1 lbs
2,488.9 lbs
967.2 lbs
0.0 lbs OK
0.0 lbs OK
Vertical component of active lateral soil pressure IS
NOT considered in the calculation of soil bearing
Lateral Load =
... Height to TO~ =
... Height to Bottom =
200.0 #/ft
11.50ft
11.50ft
Load Type Wind (!N)
(Service Level)
Wind on Exposed Stem =
(Service Level)
Stern Construction
Design Height Above Ftg
Wall Material Above "Ht"
Design Method
Thickness
Rebar Size
Rebar Spacing
Rebar Placed at
Design Data
fb/FB + fa/Fa
Total Force @Section
Service Level
Strength Level
Moment .... Actual
Service Level
Strength Level
Moment. .... Allowable
Shear ..... Actual
Service Level
Strength Level
Shear ..... Allowable
Anet (Masonry)
Rebar Depth 'd'
Masonry Data
fm
Fs
Solid Grouting
Modular Ratio 'n'
Wall Weight
16.0 psi
• 2nd
ft= 8.33
= Fence
= LRFD
=
=
=
=
=
lbs=
lbs= 56.0
ft-#=
ft-#= 98.0
ft-#=
psi=
psi=
in2=
in=
psi=
psi=
=
psf=
Adjacent Footing Load
Footing Width
Eccentricity
Wall to Ftg CL Dist
Footing Type
Base Above/Below Soil
at Back of Wall
Poisson's Ratio
Bottom
Stem OK
0.00
Concrete
LRFD LRFD
10.00
# 6
16.00
Edge
0.800
2,903.9
8,594.8
10,744.9
31.7
75.0
7.63
125.0
Load Factors-------------Short Term Factor =
Building Code
Dead Load
Live LOad
Earth, H
Wind,W
Seismic, E
CBC 2016,ACI
1.400
1.700
1.700
1.300
1.000
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
Concrete Data
fc
Fy
=
= Normal Weight
= ASD
psi= 2,500.0
psi= 60,000.0
=
=
=
=
=
0.0 lbs
1.00 ft o.oo in
0.00 ft
Line Load
0.0 ft
0.300
LRFD
•
Title R.TB.~ No Seismic Cales Page : 2
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H•8.33'TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reportslrw\2016-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Bulld 11.17.07.27
License: KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
Bottom Stem
As (based on applied moment) :
(4/3) •As:
Vertical Reinforcing
0.2614 in2/ft
0.3486 in2/ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 1.999 in2
200bd/fy: 200(12)(7.625)/60000:
0.0018bh : 0.0018(12)(10) :
0.305 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.216 in2/ft Horizontal Reinforcing Options :
One layer of: Two layers of:
Required Area :
Provided.Area:
0.305 in2/ft
0.33 in2/ft
#4@ 10.00 in #4@ 20.00 in
#5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
I Footing Dimensions & Strengths •
Toe Width
Heel Width
Total Footing Width
• •
2.04 ft
2.88
4.92
Footing Thickness 16.00 in
Key Width 12.00 in
Key Depth • 16.00 in
Key Distance from Toe 2.04 ft
fc • 2,500 psi Fy • 60,000 psi
Footing Concrete Density = 150.00 pcf
Min. As% • 0.0018
Cover@ Top 2.00· @ Btm.= 3.00 in
Footing Design Results I
~ liw
Factored Pressure 3,209 O psf
Mu' : Upward • 5,555 199 ft-#
Mu' : Downward 948 3,622 ft-#
Mu: Design 4,607 3,423 ft-#
Actual 1-Way Shear • 13.79 18.01 psi
Allow 1-Way Shear 40.00 40.00 psi
Toe Reinforcing = # 7@ 16.00 in
Heel Reinforcing = None Spec'd
Key Reinforcing • # 6 @ 16.00 in
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi*5*1ambda*sqrt(fc)*Sm
Heel: Not req'd: Mu < phi•5•1ambda•sqrt(fc)'Sm
Key: Not req'd: Mu < phi•5•1ambda•sqrt(fc)'Sm
Min footing T&S reinf Area 1.70 in2
0.35 in2 1ft Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 6.94 in
#5@ 10.76 in
#6@ 15.28 in
If two layers of horizontal bars:
#4@ 13.89 in
#5@21.53 in
#6@30.56 in
Summary of Overturning & Resisting Forces & Moments
..... OVERTURNING ..... .. ... RESISTING .....
Force Distance Moment Force Distance Moment
Item lbs ft ft-#
Heel Active Pressure =
Surcharge over Heel =
Surcharge Over Toe =
Adjacent Footing Load
Added Lateral Load
Load @ Stem Above Soil =
•
Total
•
Resisting/Overturning Ratio
2,241.1
56.0
2,297.1
Vertical Loads used for Soil Pressure=
3.22
12.83
11.41
O.T.M.
7,218.9
639.1
7,858.0
= 1.79
4,605.7 lbs
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
Soil Over Heel =
Sloped Soil Over Heel •
Surcharge Over Heel =
Adjacent Footing Load •
Axial Dead Load on Stem=
* Axial Live Load on Stem
Soil Over Toe =
Surcharge Over Toe =
Stem Weight(s)
Earth @ Stem Transitions=
Footing Weight •
Key Weight •
lbs ft ft-#
2,125.9 3.90 8,282.1
255.2
1,041.3
983.3
200.0
1.02
2.46
2.46
2.54
260.5
2,559.7
2,417.4
508.3
Vert. Component _• ____ _
Total• 4,605.7 lbs R.M.• 14,028.1
• Axial live load NOT included in total displayed! or used for overturning resistance, but is included for soil pressure ca culation.
•
Title R.TB.~ No Seismic Cales Page: 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=8.33'TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reportslrw\2016-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #6 bar specified in this stem design segment=
Development length for #6 bar specified in this stem design segment=
Hooked embedment length into footing for #6 bar specified in this stem design segment=
As Provided =
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
28.08 in
21.60 in
12.60 in
0.3300 in2/ft
0.3050 in2/ft
Title R.T8.~ Seismic Cales Page: 2
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=8.33'TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reportslrw\2016-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Bulld 11.17.07.27
License: KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
Bottom Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy : 200(12)(7.625)/60000 :
0.0018bh: 0.0018(12)(10):
Vertical Reinforcing
0.3115 in2/ft
0.4154 in2/ft
0.305 in2/ft
0.216 in2/ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 1.999 in2
Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
Required Area : 0.3115 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area : 0.33 in2/ft #5@15.50 in #5@31.00 in
Maximum Area : 1.0329 in2/ft #6@ 22.00 in #6@ 44.00 in
I Footing Dimensions & Strengths •
Toe Width
Heel Width
Total Footing Width
Footing Thickness
Key Width
Key Depth
=
=
Key Distance from Toe =
fc = 2,500 psi Fy =
Footing Concrete Density
2.04 ft
2.88
4.92
16.00 in
12.00 in
16.00 in
2.04 ft
60,000 psi
150.00 pcf
= 0.0018
2.00
Footing Design Results •
I2l! lllll
Factored Pressure 4,196 O psf
Mu' : Upward 6,809 2 ft-#
Mu' : Downward = 948 3,622 ft-#
Mu: Design 5,861 3,620 ft-#
Actual 1-Way Shear 20.14 20.96 psi
Allow 1-Way Shear 75.00 40.00 psi
Toe Reinforcing # 7@ 16.00 in
Heel Reinforcing = None Spec'd
Key Reinforcing = # 6@ 16.00 in
Other Acceptable Sizes & Spacings Min.As%
Cover@Top @ Btm.= 3.00 in Toe: #4@6.94 in, #5@ 10.76 in, #6@ 15.28 in, #7@20.83 in, #8@27.43 in, #9@34
Heel: Not req'd: Mu < phi•5•1ambda•sqrt(fc)"Sm
Key: Not req'd: Mu < phi*5*1ambda*sqrt(fc)*Sm
Min footing T&S reinf Area 1.70 in2
Min footing T&S re inf Area per foot
If one layer of horizontal bars:
0.35 in2 !ft
If two layers of horizontal bars:
#4@13.89 in #4@ 6.94 in
#5@ 10.76 in
#6@ 15.28 in
#5@21.53 in
#6@30.56 in
Summa of Overturnin & Resistin Forces & Moments
Item
Heel Active Pressure =
Surcharge over Heel =
Surcharge Over Toe =
Adjacent Footing Load
Added Lateral Load =
Load @ Stem Above Soil=
Seismic Earth Load
Total
Resisting/Overturning Ratio
••••• OVERTURNING ..... Force Distance Moment
lbs ft ft-#
2,241.1
56.0
225.4
2,522.5
3.22
12.83
11.41
6.44
0.T.M.
=
7,218.9
639.1
1,452.0
9,310.0
Vertical Loads used for Soil Pressure=
= 1.51
4,605.7 lbs
If seismic is included, the OTM and sliding ratios be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Sliding Resistance.
Vertical component of active lateral soil pressure IS NOT considered in
the calculation of Overturning Resistance.
Soil Over Heel =
Sloped Soil Over Heel =
Surcharge Over Heel =
Adjacent Footing Load =
Axial Dead Load on Stem =
'" Axial Live Load on Stem =
Soil Over Toe
Surcharge Over Toe =
Stem Weight(s) =
Earth @ Stem Transitions=
Footing Weigh!
Key Weight
. •... RESISTING ...•. Force Distance Moment
lbs ft ft-#
2,125.9 3.90 8,282.1
255.2
1,041.3
983.3
200.0
1.02
2.46
2.46
2.54
260.5
2,559.7
2,417.4
508.3
Vert. Component _= ____ _
Total= 4,605.7 lbs R.M.= 14,028.1
* Axial live load NOT included in total displayed! or used for overturning
resistance, but is included for soil pressure ca culation.
Title R.T8.~ Seismic Cales Page: 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H0 8.33TRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #6 bar specified in this stem design segment=
Development length for #6 bar specified in this stem design segment=
Hooked embedment length into footing for #6 bar specified in this stem design segment=
As Provided =
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
28.08 in
21.60 in
12.60 in
0.3300 in2/ft
0.3115 in2/ft
Title R.T10i3 No Seismic Cales Page: 2
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=10.33'TRW with 8"NICHE
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reports\rw\2016-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 License To: COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
2nd Stem
As (based on applied moment) :
(4/3) *As:
200bd/fy : 200(12)(7.5625)/60000 :
0.0018bh: 0.0018(12)(10);
Required Area :
Provided Area :
Maximum Area :
Bottom Stem
As (based on applied moment) :
(4/3) *As:
200bd/fy : 200(12)(7.5625)/60000 :
0.0018bh: 0.0018(12)(10);
Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
Vertical Reinforcing
0.1846 in2/ft
0.2461 in2/ft
0.3025 in2/ft
0.216 in2/ft
0.2461 in2/ft
0.4 in2/ft
1.0245 in2/ft
Vertical Reinforcing
0.4869 in2/ft
0.6492 in21ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 1.759 in2
Min Stem T&S Rein! Area per ft of stem Height : 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 10.00 in #4@ 20.00 in
#5@ 15.50 in #5@ 31.00 in
#6@ 22.00 in #6@ 44.00 in
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.720 in2
0.3025 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
0.216 in2/ft Horizontal Reinforcing Options:
------------One layer of: Two layers of:
Required Area : 0.4869 in2/ft #4@ 10.00 in #4@ 20.00 in
Provided Area: 0.72 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0245 in2/ft #6@ 22.00 in #6@ 44.00 in
I Footing Dimensions & Strengths l Footing Design Results l
Toe Width = 2. 71 ft I2l! J:llll
Heel Width = 3.54 Factored Pressure 3,359 0 psf
Total Footing Width 6.25 Mu': Upward = 10,363 970 ft-#
Footing Thickness = 18.00 in Mu': Downward = 1,797 7,785 ft-#
Mu: Design 8,566 6,815 ft-# Key Width
Key Depth
Key Distance from Toe
=
fc = 2,500 psi Fy =
Footing Concrete Density =
12.00 in
23.00 in
2.71 ft
60,000 psi
150.00 pcf
0.0018 Min.As%
Cover@Top 2.00 @ Btm.= 3.00 in
Actual 1-Way Shear 20.59 23.61 psi
Allow 1-Way Shear = 75.00 75.00 psi
Toe Reinforcing = # 6@ 12.00 in
Heel Reinforcing = # 6 @ 12.00 in
Key Reinforcing = # 5@ 12.00 in
Other Acceptable Sizes & Spacings
Toe: #4@ 6.17 in, #5@ 9.57 in, #6@ 13.58 in, #7@ 18.52 in, #8@24.38 in, #9@30.
Heel: #4@ 6.17 in, #5@ 9.57 in, #6@ 13.58 in, #7@ 18.52 in, #8@ 24.38 in, #9@ 30.
Key: #4@ 9.26 in, #5@ 14.35 in, #6@ 18 in, #7@ 18 in, #8@ 18
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 6.17 in
#5@ 9.57 in
#6@ 13.58 in
2.43 in2
0.39 in2 /ft
If two layers of horizontal bars:
#4@ 12.35 in
#5@ 19.14 in
#6@ 27.16 in
Title R.T10;3 No Seismic Cales Page: 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=10.33'TRW with B"NICHE
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reports\rw\2016-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License; KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 2nd
Stem Design Height: 3.00 ft above top of footing
Lap Splice length for #7 bar specified in this stem design segment=
Lap Splice length for #7 bar extending up into this stem design segment from below=
Development length for #7 bar specified in this stem design segment=
Development length for #7 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #7 bar extending down into this stem design segment from above=
Lap Splice length for #7 bar specified in this stem design segment=
Development length for #7 bar extending down into this stem design segment from above=
Development length for #7 bar·specified in this stem design segment=
Hooked embedment length into footing for #7 bar specified in this stem design segment=
As Provided =
As Required =
Code: CBC 2016,ACI 318-14,ACI 530-13
40.95 in
40.95 in
31.50 in
31.50 in
40.95 in
40.95 in
31.50 in
31.50 in
14.70 in
0. 7200 in2/ft
0.4869 in2/ft
' ' -
Title R.T10:3 Seismic Cales Page: 2
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=10.33'TRW with 8"NICHE
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016--68 abdi drainage.rpx
RetainPro (c) 1987~2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
2nd Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(7.5625)/60000:
0.0018bh: 0.0018(12)(10):
Required Area :
Provided Area :
Maximum Area :
Bottom Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(7.5625)/60000:
0.0018bh: 0.0018(12)(10):
Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
Vertical Reinforcing
0.2369 in2/ft
0.3159 in2/ft
0.3025 in2/ft
0.216 in2/ft
0.3025 in2ift
0.4 in2/ft
1.0245 in2/ft
Vertical Reinforcing
0.5797 in2/ft
0.7729 in2/ft
0.3025 in2/ft
0.216 in2/ft
Horizontal Reinforcing
Min Stem T&S Rein! Area 1.759 in2
Min Stem T&S Rein! Area per ft of stem Height: 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 10.00 in #4@ 20.00 in
#5@ 15.50 in #5@ 31.00 in
#6@ 22.00 in #6@ 44.00 in
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.720 in2
Min Stem T&S Rein! Area per ft of stem Height : 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
Required Area : 0.5797 in2/ft #4@ 1 o.oo in #4@ 20.00 in
Provided Area: 0.72 in2/ft #5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.0245 in2/ft #6@ 22.00 in #6@ 44.00 in
I Footing Dimensions & Strengths l
Toe Width
Heel Width
Total Footing Width
Footing Thickness
Key Width
Key Depth
Key Distance from Toe
=
=
=
=
=
2.71 ft
3.54
6.25
18.00 in
12.00 in
23.00 in
2.71 ft
fc = 2,500 psi Fy = 60,000 psi
150.00 pct Footing Concrete Density
Min.As%
Cover@Top 2.00
= 0.0018
@ Btm.~ 3.00 in
Footing Design Results I
I2!I lilll
Factored Pressure = 4,21 o a psf
Mu': Upward 12,367 152 ft-#
Mu': Downward = 1,797 7,785 ft-#
Mu: Design = 10,570 7,633 ft-#
Actual 1-Way Shear 25.74 28.44 psi
Allow 1-Way Shear = 75.00 75.00 psi
Toe Reinforcing = # 6@ 12.00 in
Heel Reinforcing # 6 @ 12.00 in
Key Reinforcing = # 5@ 12.00 in
Other Acceptable Sizes & Spacings
Toe: #4@ 6.17 in, #5@ 9.57 in, #6@ 13.58 in, #7@ 18.52 in, #8@ 24.38 in, #9@ 30.
Heel: #4@ 6.17 in, #5@ 9.57 in, #6@ 13.58 in, #7@ 18.52 in, #8@ 24.38 in, #9@ 30.
Key: #4@ 9.26 in, #5@ 14.35 in, #6@ 18 in, #7@ 18 in, #8@ 18
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 6.17 in
#5@ 9.57 in
#6@ 13.58 in
2.43 in2
0.39 in2 1ft
If two layers of horizontal bars:
#4@12.35 in
#5@ 19.14 in
#6@ 27.16 in
Title R.T10:3 Seismic Cales Page: 4
Job#: . Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=10.33'TRW with 8"NICHE
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reportslrw\2016--68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 2nd
Stem Design Height: 3.00 ft above top of footing
Lap Splice length for #7 bar specified in this stem design segment=
Lap Splice length for #7 bar extending up into this stem design segment from below=
Development length for #7 bar specified in this stem design segment=
Development length for #7 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length.for #7 bar extending down into this stem design segment from above=
Lap Splice length for #7 bar specified in this stem design segment=
Development length for #7 bar extending down into this stem design segment from above =
Development length for #7 bar specified in this stem design segment=
Hooked embedment length into footing for #7 bar specified in this stem design segment=
As Provided =
As Required =
Code: CBC 2016,ACI 318-14,ACI 530-13
40.95 in
40.95 in
31.50 in
31.50 in
40.95 in
40.95 in
31.50 in
31.50 in
14.?0in
0.7200 in2/ft
0.5797 in2/ft
Title R.87 ,?3 no Seismic Cales Page : 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=7.33'BW-3.67'RW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreports\rw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License: KW.06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 2nd
Stem Design Height: 2.67 ft above top of footing
Lap Splice length for #4 bar specified in this stem design segment=
Lap Splice length.for #5 bar extending up into this stem design segment from below=
Development length for #4 bar specified in this stem design segment=
Development length for #5 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length.for #4 bar extending down into this stem design segment from above =
Lap Splice length for #5 bar specified in this stem design segment=
Development length for #4 bar extending down into this stem design segment from above =
Development length for #5 bar specified in this stem design segment=
Hooked embedment length into footing for #5 bar specified in this stem design segment=
As Provided =
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
18.72 in
23.40 in
14.40 in
18.00 in
18.72 in
23.40 in
14.40 in
18.00 in
10.50 in
0.2325 in2/ft
0.1296 in2/ft
Title R.87.~3 Seismic Cales Page: 2
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=7.33'BW-3.67'RW
This Wall in File: j:~obs\2016 jobs\2016-066 -abdi drainage\reports\rw\2016-66 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License: KW-06056682 License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
2nd Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(4.25)/60000:
0.0018bh : 0.0018(12)(6) :
Required Area :
Provided Area :
Maximum Area :
Bottom Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(8.1875)/60000 :
0.0016bh : 0.0018(12)(10) :
Required Area :
Provided Area :
Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
Vertical Reinforcing
0.0137 in2/ft
0.0163 in2/ft
0.17 in2/ft
0.1296 in2/ft
0.1296 in2/ft
0.15 in2/ft
0.5757 in2/ft
Vertical Reinforcing
0.0429 in2/ft
0.0571 in2/ft
0.3275 in2/ft
0.216 in2/ft
0.216 in2/ft
0.2325 in2/ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.672 in2
Min Stem T&S Reinf Area per ft of stem Height : 0.144 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 16.67 in #4@ 33.33 in
#5@ 25.63 in #5@ 51.67 in
#6@ 36.67 in #6@ 73.33 in
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.641 in2
Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 10.00 in #4@ 20.00 in
#5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.1092 in2/ft #6@ 22.00 in #6@ 44.00 in
I Footing Dimensions & Strengths I
Toe Width
Heel Width
Total Footing Width
Footing Thickness
Key Width
Key Depth
Key Distance from Toe
=
=
=
fc = 2,500 psi Fy =
Footing Concrete Density =
1.04 ft
1.88
2.92
14.00 in
10.00 in
4.00 in
1.00 ft
60,000 psi
150.00 pcf
0.0018 Min.As%
Cover@Top 2.00 @ Btm.= 3.00 in
Footing Design Results I
~ !:!w
Factored Pressure = 2,483 O psf
Mu': Upward = 1,159 37 ft-#
Mu' : Downward = 228 481 ft-#
Mu: Design = 931 444 ft-#
Actual 1-Way Shear = 2.25 5.14 psi
Allow 1-Way Shear = 40.00 40.00 psi
Toe Reinforcing = None Spec'd
Heel Reinforcing None Spec'd
Key Reinforcing = None Spec'd
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi'5'1ambda'sqrt(fc)"Sm
Heel: Not req'd: Mu < phi'5'1ambda'sqrt(fc)"Sm
Key: Not req'd: Mu < phi"5"1ambda"sqrt(fc)"Sm
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 7.94 in
#5@ 12.30 in
#6@ 17.46 in
0.86 in2
0.30 in2 1ft
If two layers of horizontal bars:
#4@15.87 in
#5@24.60 in
#6@34.92 in
Title R.87.~3 Seismic Cales Page: 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=7.33'BW-3.67'RW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reports\rw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
J..lcense : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 2nd
Stem Design Height: 2.67 ft above top of footing
Lap Splice length for #4 bar specified in this stem design segment=
Lap Splice length for #5 bar extending up into this stem design segment from below=
Development length for #4 bar specified in this stem design segment=
Development length for #5 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #4 bar extending down into this stem design segment from above =
Lap Splice length for #5 bar specified in this stem design segment=
Development length for #4 bar extending down into this stem design segment from above =
Development length for #5 bar specified in this stem design segment=
Hooked embedment length into footing for #5 bar specified in this stem design segment=
As Provided =
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
18.72 in
23.40 in
14.40 in
18.00 in
18.72 in
23.40 in
14.40 in
18.00 in
10.50 in
0.2325 in2/ft
0.1296 in2/ft
Title R.89.67 No Seismic Cales Page : 2
Job#: . Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=9.67'BW-4" niche-5.67'RW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreports\iw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
3rd Stem
As (based on applied moment) :
(4/3) *As:
200bd/fy: 200(12)(4.25)/60000 :
0.0018bh: 0.0018(12)(6):
Required Area :
Provided Area :
Maximum Area :
2nd Stem
As (based on applied moment) :
(4/3) •As:
Vertical Reinforcing
0.0053 in2/tt
0.007 in2/ft
0.17 in21ft
0.1296 in2/ft
0.1296 in2/ft
0.15 in2/ft
0.5757 in2/ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.432 in2
Min Stem T&S Reinf Area per ft of stem Height: 0.144 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 16.67 in #4@ 33.33 in
#5@ 25.83 in #5@ 51.67 in
#6@ 36.67 in #6@ 73.33 in
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.528 in2
200bd/fy: 200(12)(4.1875)/60000:
0.0018bh: 0.0018(12)(6):
Vertical Reinforcing
0.0372 in2/ft
0.0496 in2/ft
0.1675 in2/ft
0.1296 in2/ft
Min Stem T&S Reinf Area per ft of stem Height: 0.144 in2/ft
Horizontal Reinforcing Options :
Required Area :
Provided Area :
Maximum Area :
Bottom Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy : 200(12)(8.1875)/60000 :
0.0018bh: 0.0018(12)(10):
Required Area :
Provided Area :
0.1296 in2/ft
0.2325 in2/tt
0.5673 in2/ft
Vertical Reinforcing
0.0933 in2/ft
0.1244 in2/ft
0.3275 in2/ft
0.216 in2/ft
0.216 in2/fl
0.2325 in2/ft
One layer of: Two layers of:
#4@ 16.67 in #4@ 33.33 in
#5@ 25.83 in #5@ 51.67 in
#6@ 36.67 in #6@ 73.33 in
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.720 in2
Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 10.00 in #4@ 20.00 in
#5@ 15.50 in #5@ 31.00 in
Maximum Area : 1.1092 in2/ft #6@ 22.00 in #6@ 44.00 in
I Footing Dimensions & Strengths •
Toe Width
. Heel Width
Total Footing Width
Footing Thickness
Key Width
Key Depth
Key Distance from Toe
=
=
fc = 2,500 psi Fy =
Footing Concrete Density =
1.63 ft
2.46
4.08
14.00 in
10.00 in
12.00 in
1'63 ft
60,000 psi
150.00 pcf
0.0018 Min.As%
Cover@Top 2.00 @ Btm.= 3.00 in
Footing Design Results I
l2ll !::Im
Factored Pressure = 2,140 585 psf
Mu' : Upward 2,554 1,045 ft-#
Mu' : Downward = 555 1,633 ft-#
Mu: Design 1,999 588 ft-#
Actual 1-Way Shear 8.02 3.86 psi
Allow 1-Way Shear = 40.00 40.00 psi
Toe Reinforcing None Spec'd
Heel Reinforcing = None Spec'd
Key Reinforcing # 5 @ 16.00 in
Other Acceptable Sizes & Spacings
Toe: Not req'd: Mu < phi•5•1ambda•sqrt(fc)•sm
Heel: Not req'd: Mu < phi•s•1ambda*sqrt(fc)•Sm
Key: Not req'd: Mu < phi•5•1ambda•sqrt(fc)•sm
Min footing T&S reinf Area
Min footing T&S re inf Are~ per foot
If one layer of horizontal bars:
#4@ 7.94 in
#5@ 12.30 in
#6@ 17.46 in
1.23 in2
0.30 in2 1ft
If two layers of horizontal bars:
#4@15.87in
#5@24.60 in
#6@34.92 in
Title R.B9.e7 No Seismic Cales Page : 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=9.67'BW-4" niche-5.67'RW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682
License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 3rd
Stem Design Height: 6.67 ft above top of footing
Lap Splice length for #4 bar specified in this stem design segment=
Lap Splice length for#5 bar extending up into this stem design segment from below=
Development length for #4 bar specified in this stem design segment=
Development length for #5 bar extending up into this stem design segment from below=
Stem Design Segment: 2nd
Stem Design Height: 3.00 ft above top of footing
Lap Splice length for #4 bar extending down into this stem design segment from above =
Lap Splice length for #5 bar specified in this stem design segment=
Lap Splice length for #5 bar extending up into this stem design segment from below=
Development length for #4 bar extending down into this stem design segment from above =
Development length for #5 bar specified in this stem design segment=
Development length for #5 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above =
Lap Splice length for #5 bar specified in this stem design segment=
Development length for #5 bar extending down into this stem design segment from above=
Development length for #5 bar specified in this stem design segment=
Hooked embedment length into footing for #5 bar specified in this stem design segment=
As Provided =
As Required =
Code: CBC 2016,ACI 318-14,ACI 530-13
18.72 in
23.40 in
14.40 in
18.00 in
18.72 in
23.40 in
23.40 in
14.40 in
18.00 in
18.00 in
23.40 in
23.40 in
18.00 in
18.00 in
10.50 in
0.2325 in2/ft
0.1296 in2/ft
Title R.B9.~7 Seismic Cales Page : 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H0 9.67'BW-4" niche-5.67'RW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reportslrw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar·Lap & Embedment Lengths Information
Stem Design Segment: 3rd
Stem Design Height: 6.67 ft above top of footing
Lap Splice length for #4 bar specified in this stem design segment=
Lap Splice length for #5 bar extending up into this stem design segment from below=
Development length for #4 bar specified in this stem design segment=
Development length for #5 bar extending up into this stem design segment from below=
Stem Design Segment: 2nd
Stem Design Height: 3.00 ft above top of footing
Lap Splice length for #4 bar extending down into this stem design segment from above=
Lap Splice length for #5 bar specified in this stem design segment=
Lap Splice length for#5 bar extending up into this stem design segment from below=
Development length for #4 bar extending down into this stem design segment from above =
Development length for #5 bar specified in this stem design segment=
Development length for #5 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above =
Lap Splice length for #5 bar specified in this stem design segment=
Development length for #5 bar extending down into this stem design segment from above=
Development length for #5 bar specified in this stem design segment=
Hooked embedment length into footing for #5 bar" specified in this stem design segment=
As Provided =
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
18.72 in
23.40 in
14.40 in
18.00 in
18.72 in
23.40 in
23.40 in
14.40 in
18.00 in
18.00 in
23.40 in
23.40 in
18.00 in
18.00 in
10.50 in
0.2325 in2/ft
0.1442 in2/ft
Title R.B1Q No Seismic Cales Page: 2
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=10'BRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reports\rw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682
License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
Concrete Stem Rebar Area Details
2nd Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(8.1875)/60000:
0.0018bh : 0.0018(12)(10) :
Required Area :
Provided Area :
Maximum Area :
Bottom Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy : 200(12)(11.5625)/60000 :
0.0018bh: 0.0018(12)(14):
Vertical Reinforcing
0.0727 in2/ft
0.097 in2/ft
0.3275 in2/ft
0.216 in2/ft
0.216 in2/ft
0.2325 in2/ft
1.1092 in2/ft
Vertical Reinforcing
0.2857 in2/ft
0.3809 in2/ft
0.4625 in2/ft
0.3024 in2/ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 1.279 in2
Min Stem T&S Rein! Area per ft of stem Height : 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of : Two layers of :
#4@ 10.00 in #4@ 20.00 in
#5@ 15.50 in #5@31.00 in
#6@ 22.00 in #6@ 44.00 in
Horizontal Reinforcing
Min Stem T&S Rein! Area 1.569 in2
Min Stem T&S Rein! Area per ft of stem Height : 0.336 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
Required Area : 0.3809 in2/ft #4@ 7.14 in #4@ 14.29 in
Provided Area : 0.6 in2/ft #5@ 11.07 in #5@ 22.14 in
Maximum Area : f.5664 in2/ft #6@ 15.71 in #6@31.43 in
I Footing Dimensions & Strengths l
Toe Width
Heel Width
Total Footing Width
Footing Thickness
Key Width
Key Depth
Key Distance from Toe
=
=
=
2.54 ft
3.71
6.25
18.00 in
16.00 in
21.00 in
2.54 ft
fc = 2,500 psi Fy = 60,000 psi
150.00 pcf Footing Concrete Density
Min.As%
Cover@Top 2.00
= 0.0018
@ Btm.= 3.00 in
Footing Design Results I
Ill§ Hill
Factored Pressure 3,194 0 psf
Mu' : Upward = 8,883 1,192 fl-#
Mu' : Downward 1,583 6,670 ft-#
Mu: Design 7,300 5,478 ft-#
Actual 1-Way Shear 17.76 19.54 psi
Allow 1-Way Shear = 75.00 40.00 psi
Toe Reinforcing = # 7 @ 12.00 in
Heel Reinforcing # 7 @ 12.00 in
Key Reinforcing = # 7 @ 12.00 in
Other Acceptable Sizes & Spacings
Toe: #4@6.17 in, #5@ 9.57 in, #6@ 13.58 in, #7@ 18.52 in, #8@24.38 in, #9@30.
Heel: Not req'd: Mu < phi•s•1ambda•sqrt(fc)'Sm
Key: #4@6.94 in, #5@ 10.76 in, #6@ 15.28 in, #7@ 18 in, #8@
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@6.17in
#5@ 9.57 in
#6@ 13.58 in
2.43 in2
0.39 in2 1ft
If two layers of horizontal bars:
#4@ 12.35 in
#5@ 19.14 in
#6@27.16 in
Title R.B10; No Seismic Cales Page: 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=10'BRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License: KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 2nd
Stem Design Height: 4.67 ft above top of footing
Lap Splice length for #5 bar specified in this stem design segment=
Lap Splice length for #7 bar extending up into this stem design segment from below=
Development length for #5 bar specified in this stem design segment=
Development length for #7 bar extending up into this.stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above=
Lap Splice length for #7 bar specified in this stem design segment=
Development length for #5 bar extending down into this stem design segment from above =
Development length for #7 bar specified in this stem design segment=
Hooked embedment length into footing for #7 bar specified in this stem design segment=
As Provided =
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
23.40 in
40.95 in
18.00 in
31.50 in
23.40 in
40.95 in
18.00 in
31.50 in
14.70 in
0.6000 in2/ft
0.3809 in2/ft
__ I
Title R.B1Q Seismic Cales Page: 2
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H•10'BRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reports\rw\2016--68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
2nd Stem
As (based on applied moment) :
(4/3) *As:
200bd/fy: 200(12)(8.1875)/60000:
0.0018bh: 0.0018(12)(10):
Required Area :
Provided Area :
Maximum Area :
Bottom Stem
As (based on applied moment) :
(4/3) *As:
200bd/fy : 200(12)(11.5625)/60000 :
0.0018bh: 0.0018(12)(14):
Required Area :
Provided Area :
Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
Vertical Reinforcing
0.0998 in2/ft
0.1331 in2/ft
0.3275 in2/ft
0.216 in2/ft
0.216 in2/ft
0.2325 in2/ft
1.1092 in2/ft
Vertical Reinforcing
0.3418 in2/ft
0.4558 in2/ft
0.4625 in2/ft
0.3024 in2/ft
0.4558 in2/ft
0.6 in2/ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 1.279 in2
Min Stem T&S Rein! Area per ft of stem Height : 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of : Two layers of :
#4@ 10.00 in #4@ 20.00 in
#5@ 15.50 in #5@ 31.00 in
#6@ 22.00 in #6@ 44.00 in
Horizontal Reinforcing
Min Stem T&S Rein! Area 1.569 in2
Min Stem T&S Rein! Area per ft of stem Height : 0.336 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 7.14 in #4@14.29 in
#5@ 11.07 in #5@22.14 in
Maximum Area : 1.5664 in2/ft #6@15.71 in #6@31.43in
I Footing Dimensions & Strengths I
Toe Width
Heel Width
Total Footing Width
Footing Thickness
• •
Key Width •
Key Depth •
Key Distance from Toe =
fc • 2,500 psi Fy •
Footing Concrete Density =
2.54 ft
3.71
6.25
18.00 in
16.00 in
21.00 in
2.54 ft
60,000 psi
150.00 pcf
0.0018 Min.As%
Cover@Top 2.00 @ Btm.= 3.00 in
Footing Design Results •
!22 J:lw
Factored Pressure = 3,869 o· psf
Mu' : Upward 10,394 299 ft-#
Mu' : Downward • 1,583 6,670 ft-#
Mu: Design • 8,811 6,371 ft-#
Aclual 1-Way Shear 21.68 23.82 psi
Allow 1-Way Shear 75.00 40.00 psi
Toe Reinforcing # 7@ 12.00 in
Heel Reinforcing • # 7@ 12.00 in
Key Reinforcing # 7@ 12.00 in
Other Acceptable Sizes & Spacings
Toe: #4@ 6.17 in, #5@ 9.57 in, #6@ 13.58 in; #7@ 18.52 in, #8@ 24.38 in, #9@ 30.
Heel: Not req'd: Mu < phi'5*lambda*sqrt(fc)*Sm
Key: #4@ 6.94 in, #5@ 10.76 in, #6@ 15.28 in, #7@ 18 in, #8@
Min footing T&S reinf Area
Min footing T&S reinf Area per foot
If one layer of horizontal bars:
#4@ 6.17 in
#5@ 9.57in
#6@ 13.58 in
2.43 in2
0.39 in2 Jft
If two layers of horizontal bars:
#4@12.35 in
#5@ 19.14 in
#6@27.16 in
Title R.81 Q Seismic Cales Page : 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=10'BRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreports\rw\2016-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License: KW-06056682
License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 2nd
Stem Design Height: 4.67 ft above top of footing
Lap Splice length for #5 bar specified in this stem design segment=
Lap Splice length for #7 bar extending up into this stem design segment from below=
Development length for #5 bar specified in this stem design segment=
Development length for #7 bar extending up into this stem design segment from below=
Stem Design Segment: ~ottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above =
Lap Splice length for #7 bar specified in this stem design segment=
Development length for #5 bar extending down into this stem design segment from above=
Development length for #7 bar specified in this stem design segment=
Hooked embedment length into footing for #7 bar specified in this stem design segment=
As Provided =
As Required =
Code: CBC 2016,ACI 318-14,ACI 530-13
23.40 in
40.95 in
18.00 in
31.50in
23.40 in
40.95 in
18.00 in
31.50 in
14.70 in
0.6000 in2/ft
0.4558 in2/ft
Title R.B1 Q.3 No Seismic Cales Page : 4
Job# : Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=10.3'BW/open/6'RW@ landing
This Wall in File: j:~obs\2016 jobs\2016-068-abdi drainage\reports\rw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Bulld 11.17.07.27
License : KW-06056682
License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 3rd
Stem Design Height: 6.00 ft above top of footing
Lap Splice length for #4 bar specified in this stem design segment=
Lap Splice length for #5 bar extending up into this stem design segment from below=
Development length for #4 bar specified in this stem design segment=
Development length for #5 bar extending up into this stem design segment from below=
Stem Design Segment: 2nd
Stem Design Height: 3.00 ft above top of footing
Lap Splice length for #4 bar extending down into this stem design segment from above =
Lap Splice length for #5 bar specified in this stem design segment=
Lap Splice length for #5 bar extending up into this stem design segment from below=
Development length for #4 bar extending down into this stem design segment from above=
Development length for #5 bar specified in this stem design segment=
Development length for #5 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above=
Lap Splice length for #5 bar specified in this stem design segment=
Development length for #5 bar extending down into this stem design segment from above =
Development length for #5 bar specified in this stem design segment=
Hooked embedment length into footing for #5 bar specified in this stem design segment=
As Provided =
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
18.72 in
23.40 in
14.40 in
18.00 in
18.72in
23.40 in
23.40 in
14.40 in
18.00 in
18.00 in
23.40 in
23.40 in
18.00 in
18.00 in
10.50 in
0.2325 in2/ft
0.1734 in2/ft
Title R.81Q.3 Seismic Cales Page : 4
Job# : Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=10.3'BW/open/6'RW@ landing
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reports\rw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 3rd
Stem Design Height: 6.00 ft above top of footing
Lap Splice length for #4 bar specified in this stem design segment=
Lap Splice length for #5 bar extending up into this stem design segment from below=
Development length for #4 bar specified in this stem design segment=
Development length for #5 bar extending up into this stem design segment from below=
Stem Design Segment: 2nd
Stem Design Height: 3.00 ft above top of footing
Lap Splice length for #4 bar extending down into this stem design segment from above=
Lap Splice length for #5 bar specified in this stem design·segment =
Lap Splice length for #5 bar extending up into this stem design segment from below=
Development length for #4 bar extending down into this stem design segment from above =
Development length for #5 bar specified in this stem design segment=
Development length for #5 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above=
Lap Splice length for #5 bar specified in this stem design segment=
Development length·for #5 bar extending down into this stem design segment from above=
Development length for #5 bar specified in this stem design segment=
Hooked embedment length into footing for #5 bar specified in this stem design segment=
As Provided =
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
18.72 in
23.40 in
14.40 in
18.00 in
18.72 in
23.40 in
23.40 in
14.40 in
18.00 in
18.00 in
23.40 in
23.40 in
18.00 in
18.00 in
10.50 in
0.2325 in2/ft
0.1968 in2/ft
Title R.811: No Seismic Cales Page : 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H0 11"BRW
This Wall in File: j:ljobs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016-68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Bulld 11.17.07.27
License: KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 3rd
Stem Design Height: 7.33 ft above top of footing
Lap Splice length for #5 bar specified in this stem design segment=
Lap Splice length for #7 bar extending up into this stem design segment from below=
Development length for #5 bar specified in this stem design segment=
Development length for #7 bar extending up into this stem design segment from below=
Stem Design Segment: 2nd
Stem Design Height: 2.67 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above =
Lap Splice length for #7 bar specified in this stem design segment=
Lap Splice length for#? bar extending up into this stem design segment from below=
Development length for #5 bar extending down into this stem design segment from above =
Development length for #7 bar specified in this stem design segment=
Development length for #7 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #7 bar extending down into this stem design segment from above =
Lap Splice length for #7 bar specified in this stem design segment=
Development length for #7 bar extending down into this stem design segment from above =
Development length for #7 bar specified in this stem design segment=
Hooked embedment length into footing for #7 bar specified in this stem design segment=
As Provided =
As Required =
Code: CBC 2016,ACI 318-14,ACI 530-13
23.40 in
40.95 in
18.00 in
31.50 in
23.40 in
40.95 in
40.95 in
18.00 in
31.50 in
31.50 in
40.95 in
40.95 in
31.50 in
31.50 in
14.70 in
0.4500 in2/ft
0.3699 in2/ft
Title R.811: Seismic Cales Page: 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=11'BRW
This Wall in File: j:\jobs\2016 jobs\2016-068 -abdi drainage\reports\rw\2016--68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License: KW-06056682 License To : COFFEY ENGINEERING INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 3rd
Stem Design Height: 7.33 ft above top of footing
Lap Splice length for #5 bar specified in this stem design segment=
Lap Splice length for #7 bar extending up into this stem design segment from below=
Development length for #5 bar specified in this stem design segment=
Development length for #7 bar extending up into this stem design segment from below=
Stem Design Segment: 2nd
Stem Design Height: 2.67 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above =
Lap Splice length for #7 bar specified in this stem design segment=
Lap Splice length for #7 bar extending up into this stem design segment from below=
Development length for #5 bar extending down into this stem design segment from above=
Development length for #7 bar specified in this stem design segment=
Development length for #7 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #7 bar extending down into this stem design segment from above=
Lap Splice length for #7 bar specified in this stem design segment=
Development length for #7 bar extending down into this stem design segment from above =
Development length for #7 bar specified in this stem design segment=
Hooked embedment length into footing for #7 bar specified in this stem design segment=
As Provided =
As Required =
Code: CBC 2016,ACI 318-14,ACI 530-13
23.40 in
40.95 in
18.00 in
31.50in
23.40 in
40.95 in
40.95 in
18.00 in
31.50 in
31.50 in
40.95 in
40.95 in
31.50 in
31.50 in
14.70 in
0.4500 in2/ft
0.4430 in2/ft
Title R.B11:Seismic.Calcs Page: 5
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=11'BRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License; KW-06056682
License To : COFFEY ENGINEERING, INC.
Fence
6" w/#5@ 16"
1o·w1#7@ 16°
1~~w/#7@16"
1'-0"
#7@16.in
@Toe
#7i16.in . @ enter On Key
#7@16"
@Heel
Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
3'-6" 3'-6"
• 3'-8"
•
14'-6_
• 11·-o·
4'-8"
•
•• 2'-8"
3"
2'-1"
2'-6" 1'-6" 2'-8"
2'-6" 4'-2"
S-9"
Title R.812; No Seismic Cales Page: 1
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H•12'BRW
This Wall in File: j:~obs\2016 jobs\2016-068-abdi drainage\reports\rw\2016-68 abdi drainage.rpx
~1~~~~:r,0~:t-1ii1fiil' Build 11·17·07·27 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To : COFFEY ENGINEERING, INC.
I Criteria • I Soil Data •
Allow Soil Bearing 4,000.0 psi
Equivalent Fluid Pressure Method
Active Heel Pressure = 48.0 psf/ft
Retained Height a 12.00 ft
Wall height above soil a 3.50 ft
Slope Behind Wall a 0.00
Height of Soil over Toe 12.00 in
Water height over heel a 0.0 ft Passive Pressure a 400.0 psi/ft
Soil Density, Heel a 125.00 pcf
Soil Density, Toe 125.00 pcf
Footingl[Soil Friction a 0.300
Soil height to ignore
for passive pressure a 12.00 in
I I J
l J
.,I s.u.r.c.ha.r .. g.e.L.o.a.ds ______ • I Lateral Load Applied to Stem
Surcharge Over Heel = a.a psf
• I Adjacent Footing Load
Adjacent Footing Load =
Footing Width NOT Used To Resist Sliding & Overturning
Surcharge Over Toe a.a psf
NOT Used for Sliding & Overturning
I Axial Load Applied to Stem I
Axial Dead Load
Axial Live Load =
Axial Load Eccentricity =
0.0 lbs
0.0 lbs
0.0 in
Lateral Load
... Height to To>
... Height to Bottom
Load Type
200.0 #/ft
15.50 ft
15.50 ft
• Wind (:JV)
(Service Level)
Wind on Exposed Stem =
(Service Level)
16.0 psi
Eccentricity
Wall to Ftg CL Dist
Footing Type
Base Above/Below Soil
at Back of Wall
Poisson's Ratio
0.0 lbs
1.00 ft
0.00 in
0.00 ft
Line Load
0.0ft
0.300
•
I Design Summary • f Stem Construction • __ 4_t_h ___ 3_rd ___ 2_n_d ___ B_ott_o_m ___ _
• Stem OK Stem OK Stem OK Wall Stability Ratios
Overturning
Sliding
Total Bearing Load
... resultant ecc.
a
a
2.04 OK
1.50 OK
9,612 lbs
15.83 in
Soil Pressure @Toe 2,779 psi OK
Soil Pressure @ Heel O psi OK
Allowable • 4,000 psi
Soil Pressure Less Than Allowable
ACI Factored @ Toe • 3,891 psi
ACI Factored @ Heel O psi
Footing Shear@ Toe =
Footing Shear@ Heel •
Allowable •
Sliding Cales
Lateral Sliding Force =
less 100% Passive Force =
less 70 °/o Friction Force
Added Force Req'd •
... .for 1.5 Stability =
22.0 psi OK
24.9 psi OK
75.0 psi
4,538.7 lbs
4,800.0 lbs
2,018.5 lbs
0.0 lbs OK
0.0 lbs OK
Vertical component of active lateral soil pressure IS·
NOT considered in the calculation of soil bearing
Load Factors-------------
Building Code
Dead Load
Live Load
Earth, H
Wind,W
Seismic, E
CBC 2016,ACI
1.400
1.700
1.700
1.300
1.000
Design Height Above Fig ft• 12.00 7.33 2.67 0.00
Wall Material Above "Ht" Fence Concrete Concrete Concrete
Design Method LRFD LRFD LRFD LRFD
Thickness • 10.00 16.00 18.00
Rebar Size # 5 # 6 # 7
Rebar Spacing 16.00 14.00 12.00
Rebar Placed at Edge Edge Edge
Design Data
fb/FB + fa/Fa • 0.224 0.530 0.611
Total Force@Section
Service Level lbs =
Strength Level lbs•
Moment. ... Actual
Service Level ft-#=
Strength Level ft-#•
Moment... .. Allowable ft-#•
Shear ..... Actual
Service Level psi=
Strength Level psi=
Shear ..... Allowable =
Anet (Masonry) in2 •
Rebar Depth 'd' in=
Masonry Data
rm psi=
Fs psi=
Solid Grouting
Modular Ratio 'n'
Wall Weight
a
psi•
a
56.0
98.0
962.6
1,852.5
8,279.1
9.8
75.0
8.19
125.0
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
• Normal Weight
ASD
3,624.4
11,852.1
22,368.3
22.2
75.0
13.63
200.0
5,948.0
24,501.8
40,107.2
31.9
75.0
15.56
225.0
Concrete Data -------------------------
re
Fy
psi=
psi=
2,500.0
60,000.0
2,500.0
60,000.0
2,500.0
60,000.0
Title R.B12: No Seismic Cales Page: 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=12'BRW
This Wall in File: j:~obs\2016 jobs\2016-066 -abdi drainage\reportslrw\2016-66 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 3rd
Stem Design Height: 7 .33 ft above top of footing
Lap Splice length for #5 bar specified in this stem design segment=
Lap Splice length for #6 bar extending up into this stem design segment from below=
Development length for #5 bar specified in this stem design segment=
Development length for #6 bar extending up into this stem design segment from below=
Stem Design Segment: 2nd
Stem Design Height: 2.67 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above =
Lap Splice length for #6 bar specified in this stem design segment=
Lap Splice length for#7 bar extending up into this stem design segment from below=
Development length for #5 bar extending down into this stem design segment from above =
Development length for #6 bar specified in this stem design segment=
Development length for #7 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #6 bar extending down into this stem design segment from above =
Lap Splice length for #7 bar specified in this stem design segment=
Development length for #6 bar extending down-into this stem design segment from above =
Development length for #7 bar specified in this stem design segment=
Hooked embedment length into footing for #7 bar specified in this stem design segment=
As Provided =
As Required =
Code: CBC 2016,ACI 318-14,ACI 530-13
23.40 in
28.08 in
16.00 in
21.60 in
23.40 in
28.08 in
40.95 in
18.00 in
21.60 in
31.50in
28.06 in
40.95 in
21.60 in
31.50 in
14.70 in
0.6000 in2/ft
0.4762 in2/ft
Title R.B1Z Seismic Cales Page : 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=12'BRW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reportslrw\2016-68 abdi drainage.rpx
RetalnPro (c) 1907-2017, Build 11.17.07.27
License : KW-06056602 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 3rd
Stem Design Height: 7.33 ft above top of footing
Lap Splice length for #5 bar specified in this stem design segment=
Lap Splice length for #6 bar extending up into this stem design segment from below=
Development length for #5 bar specified in this stem design segment=
Development length for #6 bar extending up into this stem design segment from below=
Stem Design Segment: 2nd
Stem Design Height: 2.67 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above =
Lap Splice length for #6 bar specified in this stem design segment=
Lap Splice length for #7 bar extending up into this stem design segment from below=
Development length for #5 bar extending down into this stem design segment from above=
Development length for #6 bar specified in this stem design segment=
Development length for #7 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #6 bar extending down into this stem design segment from above=
Lap Splice length for #7 bar specified in this stem design segment=
Development length for #6 bar extending down into this stem design segment from above=
Development length for #7 bar specified in this stem design segment=
Hooked embedment length into footing for #7 bar specified in this stem design segment=
As Provided =
As Required=
Code: CBC 2016,ACI 318-14,ACI 530-13
23.40 in
28.08 in
18.00 in
21.60 in
23.40 in
28.08 in
40.95 in
18.00 in
21.60 in
31.50in
28.08 in
40.95 in
21.60 in
31.50 in
14.70 in
0.6000 in2/ft
0.5713 in2/ft
Title R.812:.83 No Seismic Cales Page: 1
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=12.83'BW-8" niche-9.33'RW
This Wall in File: j:\jobs\2016 jobs\2016-068 -abdi drainage\reports\rw\2016--68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To · COFFEY ENGINEERING INC
I Criteria • Ison Data • Retained Height = 9.33 ft Allow Soil Bearing = 4,000.0 psi
Wall height above soil = 3.50 ft Equivalent Fluid Pressure Method -Active Heel Pressure = 48.0 psi/ft
Slope Behind Wall = 0.00
Height of Soil over Toe = 12.00 in =
0.0 ft Passive Pressure = 400.0 psf/ft Water height over heel = Soil Density, Heel = 125.00 pcf
Soil Density, Toe = 125.00 pcf
FootingJISoil Friction = 0.300 mqB.
Soil height to ignore [ I
for passive pressure = 12.00 in I
'-ii S!!'u•r"!'c•h•ar .. g!!"e•L""!o'!"a""!d•s-----.. 1 I Lateral Load Applied to Stem I I Adjacent Footing Load I
Surcharge Over Heel = o.o psi Lateral Load 200.0 #/ft Adjacent Footing Load = 1,661.0 lbs
NOT Used To Resist Sliding & Overturning ... Height to To~ = 0.00 ft Footing Width 2.92 ft
Surcharge Over Toe 0.0 psi ... Height to Bottom 0.00 ft Eccentricity = 6.76 in
NOT Used for Sliding & Overturning Load Type Wind c,N) Wall to Ftg CL Dist = 3.83 ft I Axial Load Applied to Stem • (Service Level) Footing Type Line Load
Base Above/Below Soil -3.3 ft Axial Dead Load = 0.0 lbs Wind on Exposed Stem ::: 16.0 psi at Back of Wall
Axial Live Load = 0.0 lbs (Service Level) Poisson's Ratio = 0.300 Axial Load Eccentricity = 0.0 in
I Design Summary • I Stem Construction • 4th 3rd 2nd Bottom
Stem OK Stem OK Stem OK Stem OK Wall Stability Ratios Design Height Above Fig ft= 9.33 7.00 3.50 0.00
Overturning = 1.76 OK Wall M8terial Above "Ht" Concrete Concrete Concrete Concrete
Sliding 1.55 OK Design Method = LRFD LRFD LRFD LRFD
Thickness 6.00 6.00 6.00 10.00
Total Bearing Load 6,322 lbs Rebar Size = # 4 # 5 # 6 # 7
... resultant ecc. = 15.30 in Rebar Spacing = 16.00 16.00 16.00 12.00
Rebar Placed at = Edge Edge Edge Edge Soil Pressure@ Toe 2,779 psf OK Design Data Soil Pressure @ Heel 0 psi OK fb/FB + fa/Fa = 0.046 0.115 0.702 0.737
Allowable 4,000 psi Total Force @Section Soil Pressure Less Than Allowable
ACI Factored @ Toe 3,890 psi Service Level lbs=
ACI Factored @ Heel = O psi Strength Level lbs= 72.8 294.3 1,656.1 4,308.4
Footing Shear@ Toe = 19.2 psi OK Moment .... Actual
Service Level ft-#= Footing Shear@ Heel = 20.1 psi OK Strength Level ft-#= 127.4 469.1 3,371.5 13,630.5 Allowable = 75.0 psi
Sliding Cales Moment. .... Allowable ft-#= 2,749.3 4,094.1 4,804.9 18,507.2
Lateral Sliding Force 3,332.1 lbs Shear ..... Actual
less 100% Passive Force ::: 3,850.0 lbs Service Level psi:::
Jess 70 % Friction Force = 1,327.6 lbs Strength Level psi::: 1.4 5.9 38.1 47.5
Added Force Req'd 0.0 lbs OK Shear ..... Allowable psi::: 75.0 75.0 75.0 75.0
... .for 1.5 Stability 0.0 lbs OK Anet (Masonry) inz:::
Rebar Depth 'd' in::: 4.25 4.19 3.63 7.56
Masonry Data
rm psi:::
Fs psi:::
Vertical component of active lateral soil pressure JS Solid Grouting
Modular Ratio 'n' = NOT considered in the calculation of soil bearing Wall Weight psi= 75.0 75.0 75.0 125.0
Load Factors Short Term Factor =
Building Code CBC 2016,ACI Equiv. Solid Thick.
Dead Load 1.400 Masonry Block Type = Normal Weight
Live Load 1.700 Masonry Design Metho? = ASD
Earth, H 1.700 Concrete Data
Wind,W 1.300 fc psi::: 2,500.0 2,500.0 2,500.0 2,500.0
Seismic, E 1.000 Fy psi::: 60,000.0 60,000.0 60,000.0 60,000.0
Title R.812.83 No Seismic Cales Page: 2
Job#: . Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H•12.83'BW-8" niche-9.33'RW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reportslrw\2016-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Build 11.17.07.27
License: KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
4th Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(4.25)/60000:
0.0018bh : 0.0018(12)(6) :
Required Area :
Provided Area :
Maximum Area :
3rd Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(4.1875)/60000:
0.0018bh: 0.0018(12)(6):
Required Area :
Provided Area :
Maximum Area :
2nd Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(3.625)/60000:
0.0018bh: 0.0018(12)(6):
Required Area :
Provided Area :
Maximum Area :
Bottom Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(7.5625)/60000:
0.0018bh : 0.0018(12)(10) :
Required Area :
Provided Area :
Maximum Area :
Vertical Reinforcing
0.0072 in2/ft
0.0096 in2/ft
0.17 in2/ft
0.1296 in2/ft
0.1296 in2/ft
0.15 in2/ft
0.5757 in2/ft
Vertical Reinforcing
0.0269 in2/ft
0.0359 in2/ft
0.1675 in2/ft
0.1296 in2/ft
:::===========
0.1296 in2/ft
0.2325 in2/ft
0.5673 in2/ft
Vertical Reinforcing
0.2266 in2/ft
0.3021 in2/ft
0.145 in2/ft
0.1296 in2/ft
0.2266 in2/ft
0.33 in2/ft
0.4911 in2/ft
Vertical Reinforcing
0.4182 in2/ft
0.5575 in2/ft
0.3025 in2/ft
0.216 in2/ft
0.4182 in2/ft
0.6 ln2/ft
1.0245 in2/ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.504 in2
Min Stem T&S Reinf Area per ft of stem Height : 0.144 in2/ft
Horizontal Reinforcing Options :
One layer of : Two layers of :
#4@ 16.67 in #4@ 33.33 in
#5@ 25.83 in #5@ 51.67 in
#6@ 36.67 in #6@ 73.33 in
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.336 in2
Min Stem T&S Reinf Area per ft of stem Height: 0.144 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 16.67 in #4@ 33.33 in
#5@ 25.83 in #5@ 51.67 in
#6@ 36.67 in #6@ 73.33 in
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.504 in2
Min Stem T&S Reinf Area per ft of stem Height : 0.144 ln2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 16.67 in #4@ 33.33 in
#5@ 25.83 in #5@ 51.67 in
#6@ 36.67 in #6@ 73.33 in
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.840 in2
Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of : Two layers of :
#4@ 10.00 in #4@ 20.00 in
#5@ 15.50 in #5@ 31.00 in
#6@ 22.00 in #6@ 44.00 in
Title R.812:,83 No Seismic Cales Page : 4
Job#: Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=12.83'BW-8" niche-9.33'RW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016:-68 abdi drainage.rpx
RetainPro (c) 1987·2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 4th
Stem Design Height: 9.33 ft above top of footing
Lap Splice length for #4 bar specified in this stem design segment=
Lap Splice length. for #5 bar extending up into this stem design segment from below=
Development length for #4 bar specified in this stem design segment=
Development length.for #5 bar extending up into this stem design segment from below=
Stem Design Segment: 3rd
Stem Design Height: 7.00 ft above top of footing
Lap Splice length for #4 bar extending down into this stem design segment from above =
Lap Splice length for #5 bar specified in this stem design segment=
Lap Splice length for #6 bar extending up into this stem design segment from below=
Development length for #4 bar extending down.into this stem design segment from above=
Development length for #5 bar specified in this stem design segment=
Development length for #6 bar extending up into this stem design segment from below=
Stem Design Segment: 2nd
Stem Design Height: 3.50 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above=
Lap Splice length for #6 bar specified in this stem design segment=
Lap Splice length for #7 bar extending up into this stem design segment from below=
Development length for #5 bar extending down into this stem design segment from above=
Development length for #6 bar specified in this stem design segment=
Development length for #7 bar extending up into this stem design segment from below=
Stem Design Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #6 bar extending down into this stem design segment from abOve =
Lap Splice length for #7 bar specified in this stem design segment =
Development length for #6 bar extending down into this stem design segment from above=
Development length for #7 bar specified in this stem design segment=
Hooked embedment length into footing for #7 bar specified in this stem design segment=
As Provided =
As Required =
Code: CBC 2016,ACI 318-14,ACI 530-13
18.72 in
23.40 in
14.40 in
18.00 in
18.72in
23.40 in
28.08 in
14.40 in
18.00 in
21.60 in
23.40 in
28.08 in
40.95 in
18.00 in
21.60 in
31.50 in
28.08 in
40.95 in
21.60 in
31.50 in
14.70in
0.6000 in2/ft
0.4182 in2/ft
Title R.812.83 No Seismic Cales Page: 5
Job#: . Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=12.83'BW-8'" niche-9.33'RW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016-68 abdi drainage.rpx
RetainPro (c) 1987-2017, Bulld 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
fr'w/#4@16"
G"w/#5@ 16"
6" w/#6@ 16"
10~ w/ #7@ 12g
1'-0"
#6@12.in
@Toe
#5@12.in
@ Center On Key
Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
• 3"-5" 3"-5"
• ,... .
•
12"-10" •
3·.5·
9'-4"
• 3'-6-
•
1·-5-
3"
2"-0"
2"-5" 10·
z.s· 3·.3·
s·-r
Title R.B1 Z,83 Seismic Cales Page : 1
Job# : Dsgnr: COFFEY ENG. INC. Dale: 12 SEP 2017
Description ....
H=12.83'BW-8" niche-9.33'RW
This Wall in File: j:~obs\2016 jobs\2016-068 • abdi drainage\reports\rw\2016--68 abdi drainage.rpx
RetalnPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13
License To · COFFEY ENGINEERING INC '
I Criteria • I Soil Data • Retained Height = 9.33 ft Allow Soil Bearing = 4,000.0 psf
Wall ~eight above soil = 3.50 ft Equivalent Fluid Pressure Method
Active Heel Pressure = 48.0 psf/ft
Slope Behind Wall = 0.00
Height of Soil over Toe = 12.00 in =
Water height over heel 0.0 ft Passive Pressure = 400.0 psf/ft =
Soil Density, Heel = 125.00 pcl
Soil Density, Toe = 125.00 pcl
FootingJISoil Friction = 0.300 -· I I Soil height to ignore
for passive pressure = 12.00 in
I '-i s.u.r.c.h.a .. rg•e•L•o•a•d•s ______ , I Lateral Load Applied to Stem I I Adjacent Footing Load
Surcharge Over Heel 0.0 psf
NOT Used To Resist Sliding & Overturning
Surcharge Over Toe = 0.0 psf
NOT Used for Sliding & Overturning
I Axial Load Applied to Stem
Axial Dead Load = 0.0 lbs
Axial Live Load 0.0 lbs
Axial Load Eccentricity 0.0 in
I Earth Pressure Seismic Load • Method : Inverted Triangular
Lateral Load =
... Height to To~ =
... Height to Bottom =
Load Type
Wind on Exposed Stem =
(Service Level)
200.0 #/ft
0.00 ft
0.00 ft
Wind ry,J)
(Service Level)
16.0 psi
Adjacent Footing Load
Footing Width
Eccentricity
Wall to Ftg CL Dist
Footing Type
Base Above/Below Soil
at Back of Wall
Poisson's Ratio
Total Strength-Level Seismic Load .... .
Load at top of Inverted Triangular Distribution . . . . . . =
(Strength)
74.640 psf Total Service-Level Seismic Load .... .
= 1,661.0 lbs
= 2.92 ft
= 6.76 in
3.83 ft
Line Load
= -3.3 ft
0.300
404.176 lbs
282.923 lbs
I
I Design Summary • ,,s.te.m .. c.o .. n.st•r•u•c•ti•o•n ...... •-~4t~h~--~3r~d __ ~2~n~d~_~B~o~tt~o~m~---
, • Stem OK Stem OK Stem OK Stem OK Wall Stability Ratios
Overturning
Sliding
Total Bearing Load
... resultant ecc.
=
=
=
1.52 OK
1.43 Ratio < 1.5!
6,322 lbs
19.18 in
Soil Pressure @Toe 3,531 psi OK
Soil Pressure @ Heel O psi OK
Allowable = 4,000 psf
Soil Pressure Less Than Allowable
ACI Factored @ Toe = 4,943 psi
ACI Factored @ Heel O psi
Footing Shear@ Toe 24.2 psi OK
Footing Shear@ Heel 23.6 psi OK
Allowable = 75.0 psi
Sliding Cales
Lateral Sliding Force
less 100% Passive Force =
· less 70 % Friction Force =
Added Force Req'd
... .for 1.5 Stability
=
=
3,615.0 lbs
3,850.0 lbs
1,327.6 lbs
0.0 lbs OK
244.9 lbs NG
Vertical component of active lateral soil pressure JS
NOT considered in the calculation of soil bearing
Load Factors -------------
Building Code
Dead Load
Live Load
Earth,H
Wind,W
Seismic. E
CBC 2016,ACI
1.400
1.700
1.700
1.300
1.000
Design Height Above Fig ft= 9.33 7.00 3.50 0.00
Wall Material Above "Ht" = Concrete Concrete Concrete Concrete
Design Method = LRFD LRFD LRFD LRFD
Thickness = 6.00 6.00 6.00 10.00
RebarSize = # 4 # 5 # 6 # 7
Rebar Spacing = 16.00 16.00 16.00 12.00
Rebar Placed at = Edge Edge Edge Edge
Design Data --------------------------
fb/FB + fa/Fa o.046 0.161 0.918 0.862
Total Force@Section
Service Level
Strength Level
Moment .... Actual
Service Level
Strength Level
Moment. .•.. Allowable
Shear ..... Actual
Service Level
Strength Level
Shear ..... Allowable
Anet (Masonry)
Rebar Depth 'd'
lbs=
lbs=
ft-#=
ft-#=
ft-#=
psi=
psi=
psi=
in2=
in=
72.8
127.4
2,749.3
1.4
75.0
4.25
449.5
657.1
4,094.1
8.9
75.0
4.19
1,974.1
4,412.4
4,804.9
45.4
75.0
3.63
4,704.8
15,946.3
18,507.2
51.8
75.0
7.56
MasonryData -------------------------
fm
Fs
Solid Grouting
Modular Ratio 'n'
Wall Weight
Short Term Factor
Equiv. Solid Thick.
Masonry Block Type
Masonry Design Method
psi=
psi=
=
psf=
=
75.0
= Normal Weight
ASD
75.0 75.0 125.0
Concrete Data -------------------------
fc
Fy
psi= 2,500.0
psi= 60,000.0
2,500.0
60,000.0
2,500.0
60,000.0
2,500.0
60,000.0
Title R.812.83 Seismic Cales Page: 2
Job#: . Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=12.83'BW-8" niche-9.33'RW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainage\reports\rw\2016--68 abdi drainage.rpx
.RetainPro {c) 1987-2017, Build 11.17.07.27
License: KW-06056682 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,ACI 530-13 License To : COFFEY ENGINEERING, INC.
Concrete Stem Rebar Area Details
4th Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(4.25)/60000:
0.0018bh: 0.0018(12)(6):
Required Area :
Provided Area :
Maximum Area :
3rd Stem
As (based on applied momenl) :
(4/3) •As:
200bd/fy: 200(12)(4.1875)/60000:
0.0018bh: 0.0018(12)(6):
Required Area :
Provided Area :
Maximum Area :
2nd Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(3.625)/60000:
0.0018bh: 0.0018(12)(6):
Required Area :
Provided Area :
Maximum Area :
Bottom Stem
As (based on applied moment) :
(4/3) •As:
200bd/fy: 200(12)(7.5625)/60000:
0.001Bbh: 0.0018(12)(10):
Required Area :
Provided Area :
Maximum Area :
Vertical Reinforcing
0.0072 in2/ft
0.0096 in2/ft
0.17 in2/ft
0.1296 in2/ft
0.1296 in2/ft
0.15 in2/ft
0.5757 in2/ft
Vertical Reinforcing
0.0377 in2/ft
0.0503 in2/ft
0.1675 in2/ft
0.1296 in2/ft
0.1296 in2/ft
0.2325 in2/ft
0.5673 in2/ft
Vertical Reinforcing
0.2966 in2/ft
0.3954 in2/ft
0.145 in2/ft
0.1296 in2/ft
0.2966 in2/ft
0.33 in2/ft
0.4911 in2/ft
Vertical Reinforcing
0.4892 in2/ft
0.6523 in2/ft
0.3025 in2/ft
0.216 in21ft
0.4892 in2/ft
0.6 in2/ft
1.0245 in2/ft
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.504 in2
Min Stem T&S Reinf Area per ft of stem Height : 0.144 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 16.67 in #4@ 33.33 in
#5@ 25.83 in #5@ 51.67 in
#6@ 36.67 in #6@ 73.33 in
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.336 in2
Min Stem T&S Reinf Area per ft of stem Height: 0.144 in2/ft
Horizontal Reinforcing Options :
One layer of : Two layers of :
#4@ 16.67 in #4@ 33.33 in
#5@ 25.83 in #5@ 51.67 in
#6@ 36.67 in #6@ 73.33 in
Horizontal Reinforcing
Min Stem T&S Reinf Area 0.504 in2
Min Stem T&S Reinf Area per ft of stem Height: 0.144 in2/ft
Horizontal Reinforcing Options :
One layer of: Two layers of:
#4@ 16.67 in #4@ 33.33 in
#5@ 25.83 in #5@ 51.67 in
#6@ 36.67 in #6@ 73.33 in
Horizontal Reinforcing
Min Siem T&S Reinf Area 0.840 in2
Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft
Horizontal Reinforcing Options :
One layer of : Two layers of :
#4@ 10.00 in #4@ 20.00 in
#5@ 15.50 in #5@ 31.00 in
#6@ 22.00 in #6@ 44.00 in
Title R.812·.83 Seismic Cales Page : 4
Job#: . Dsgnr: COFFEY ENG. INC. Date: 12 SEP 2017
Description ....
H=12.83'BW-8" niche-9.33'RW
This Wall in File: j:~obs\2016 jobs\2016-068 -abdi drainagelreportslrw\2016-68 abdi drainage.rpx
RetaJnPro (c) 1987-2017, Build 11.17.07.27
License : KW-06056682 License To : COFFEY ENGINEERING, INC.
Cantilevered Retaining Wall
Rebar Lap & Embedment Lengths Information
Stem Design Segment: 4th
Stem Design Height: 9.33 ft above top of footing
Lap Splice length for #4 bar specified in this stem design segment=
Lap Splice length for #5 bar extending up into this stem design segment from below=
Development length for #4 bar specified in this stem design segment=
Development length for #5 bar extending up into this stem design segment from below=
Stem Design Segment: 3rd
Stem Design Height: 7.00 ft above top of footing
Lap Splice length for #4 bar extending down into this stem design segment from above=
Lap Splice length for #5 bar specified in this stem design segment=
Lap Splice length for #6 bar extending up into this stem design segment from below=
Development length for #4 bar extending down into this stem design segment from above=
Development length for #5 bar specified in this stem design segment=
Development length for #6 bar extending up into this stem design segment from below=
Stem Design Segment: 2nd
Stem Design Height: 3.50 ft above top of footing
Lap Splice length for #5 bar extending down into this stem design segment from above =
Lap Splice length for #6 bar specified in this stem design segment=
Lap Splice length for #7 bar extending up into this stem design segment from below=
Development length for #5 bar extending down into this stem design segment from above=
Development length for #6 bar specified in this stem design segment=
Development length for #7 bar extending up into this stem design segment from below=
Stem·oesign Segment: Bottom
Stem Design Height: 0.00 ft above top of footing
Lap Splice length for #6 bar extending down into this stem design segment from above =
Lap Splice length for #7 bar specified in this stem design segment=
Development length for #6 bar extending down into this stem design segment from above=
Development length for #7 bar specified in this stem design segment=
Hooked embedment length into footing for #7 bar specified in this stem design segment=
As Provided=
As Required =
Code: CBC 2016,ACI 318-14,ACI 530-13
18.72 in
23.40 in
14.40 in
18.00 in
18.72 in
23.40 in
28.08 in
14.40 in
18.00 in
21.60 in
23.40 in
28.08 in
40.95 in
18.00 in
21.60 in
31.50 in
28.06 in
40.95 in
21.60 in
31.50 in
14.70 in
0.6000 in2/ft
0.4892 in2/ft
is COFFEY ENGINEERING, INC.
9666 Businesspark Avenue, Suite 210
San Diego, CA 92131
September 1, 2017
TO: KAISER PERMENANTE
RE: BROKER OF RECORD CHANGE
Effective immediately, I hereby appoint Karen Winters with Winters Insurance Services as the broker
of record for our policy listed below.
Coffey Engineering 337997
As the new agent, Karen Winters, supersedes other designations, and terminates commissions and
other payments to any other agent.
Please direct all future agent correspondence to:
Karen L. Winters
Winters Insurance Services
701 Kettner Boulevard, #106
San Diego, CA 92101
(619) 370-4355
Karen@WinterslS.com
Agent ID# OH32297
Agency ID# OL90896
E&O Policy# 596427449
You are hereby authorized to release any applicable account information, including insurance
contracts, rates, rating schedules, renewals, loss experience, and any other policy data required to
fully assess the policy holders' coverage, rate structure and policy amendments.
Sincerely,
Charlene Nash
Chief Financial Officer