Loading...
HomeMy WebLinkAboutCDP 2017-0021; OCEAN STREET RESIDENCE; ADDENDUM TO LIMITED GEOTECHNICAL INVESTIGATION; 2018-07-08Alan Shafran EAST COUNTY SOIL CONSULTATION AND ENGINEERJNG, INC. 10925 HARTLEY ROAD, SUITE "I" SANTEE, CALIFORNIA 92071 (619) 258-7901 Fax (619) 258-7902 1673 Amante Court Carlsbad, California 92011 Subject: Addendum to Limited Geotechnical [nvestigation Proposed Single-Fa111ily Residence 2680 Ocean Street , City of Carlsbad, California 92008 1<e eor~ U>Fj 1:.(!-f11~ED AUG O 2 2018 LAND DEVELOPMENT CNGINEERING July8,2018 Project No. 17-110605 pr~~e-i tD: CDP2011 -002( t)o)G, )1.0 •• Ou(; ~ lO, '4 l"r GR Y\O ·• G:R2.01~-0GOq Reference: "Limited Geotechnical Investigation. Proposed Single-Family Residence, 2680 Ocean Street, City of Carlsbad, California," Project No. 17-1106D5, Prepared by East County Soil Consultation and Engineering, Inc., Dated March 2. 2017. Dear Mr. Shafran: In accordance with your request, we have prepared this addendum to address the retaining walls for the proposed single-family residence at the subject site. The grading plans prepared by Pacific Overland Engineering & Surveying of Vista, California indicate the existing retaining wall at the rear of the property will be replaced with a new one. The new wall will have a maximum height of 5 .33 feet and a setback of 10 inches from the rear property line. Questions have been raised regarding the type of backfill and the proposed 6-foot high vertical cut behind the wall to facilitate construction. Based on the dense consistency of the underlying terrace deposits, it is our opinion that a temporary vertical cut up to 6 feet will be stable. Due to the setback limitation, the retaining wall backfill may consist ofa I-inch maximum open-graded aggregate (drain rock) wrapped in a Miraft 140N filter fabric or equivalent. Cantilevered retaining walls should be designed for an "active" lateral earth pressure or 35 pstlft (35 pcf EFP) for approved granular and level backfill conditions. Where the walls support 21 I: 1 V sloping backfill, the equivalent active fluid pressure should be increased to 45 pcf. Walls subject to uniform surcharge loads should be designed for an additional uniform lateral pressure equal to one-third (1/3) the anticipated surcharge pressure. Another additional lateral earth pressure due to earthquake motions of 26 pcf EFP may be applied using an inverted triangular distribution if required. Soil design criteria, such as bearing capacity, passive earth pressure and sliding resistance as recommended under the Foundation and Slab recommendations section of the referenced geotechnical report may be incorporated in the retaining wall design. Footings should be reinforced as recommended by the structural engineer and appropriate back drainage provided to avoid excessive hydrostatic wall pressures. As a minimum, we recommend a fabric-wrapped crushed rock and perforated pipe system. If we can be of any further assistance, please do not hesitate to contact our office. Mamadou Saliou Diallo, P.E. RCE 54071, GE 2704 MSD\md