HomeMy WebLinkAboutCT 01-10; Village by the Sea; Updated Geotechnical Investigation; 2002-04-08Updated Geotechnical Investigation "Village By The Sea" Residential Development 2700 Carlsbad Boulevard Carlsbad, California Prepared For: Anastasi Development 1200 Aviation Boulevard Redondo Beach, California 90278 Attn.: Mr. Chuck Springfield Project Number 8710-00 April 8, 2002 SEP 2 9 2002 ENGlNEERiNC-i DEPARTMENT' NorCal Engineering Soils and Geotechnical Consultants 10641 Humbolt Street Los Alamitos, CA 90720 (562)799-9469 Fax (562)799-9459 September 6, 2002 Project Number 8710-00 O'Day Consultants 5900 Pasteur court. Suite 100 Carlsbad, California 92008-7317 Attn.: Mr. George O'Day RE: Review of Grading Plans - Proposed "Village By the Sea" Residential Development - Located at 2700 Carlsbad Boulevard, Carlsbad, California Dear Mr. O'Day: Pursuant to your request, this firm has reviewed your latest grading plans stamp dated August 27, 2002 for the above referenced project. The plans appear to be geotechnically acceptable for the proposed development and conform to recommendations provided in our approved geotechnical report. We appreciate this opportunity to be of service to you. If you have any further questions, please do not hesitate to contact the undersigned. Respectfully submitted, NORCAL ENGINEERING Keith D. Tucker Project Engineer R.G.E. 841 Scott D. Spensiero Project Manager SEP 2 0 WU EmmEERmQ BEPARTMEMT NorCal Engineering SOILS AND GEOTECHNICAL CONSULTANTS 10641 HUMBOLT STREET LOS ALAMITOS, CA 90720 (562)799-9469 FAX (562)799-9459 April 8, 2002 Project Number 8710-00 Anastasi Development 1200 Aviation Boulevard Redondo Beach, California 90278 Attn.: Mr. Chuck Springfield RE: Updated Geotechnical Investigation - Proposed "Village By The Sea" Residential Development - Located at 2700 Carlsbad Boulevard, in the City of Carlsbad, California Dear Mr. Springfield : Pursuant to your request, this firm has performed an updated Geotechnical Investigation for the above referenced project in accordance with your authorization of our verbal proposal. The purpose of this investigation is to evaluate the geotechnical conditions of the subject site and to provide updated recommendations for the proposed project. This geotechnical engineering report presents the finding of our study along with conclusions and recommendations for development. We appreciate this opportunity to be of service to you. If you have any further questions, please do not hesitate to contact the undersigned. Respectfully s NORCAL E Keith D. Tdfcl*^ "^^^ Ji, Troy D. Norrell Project Eng%!g%;.p^„^vcJ^V>/ President R.G.E. 841 April 8, 2002 Page 2 Project Number 8710-00 Proiect npyrriptinn The purpose of .he inves.iga,ion «as ,o explore the subsurface conditions and ,o provide prelrminary geoechnlca, engineering design para.e.er. for evaluation of ,he sL w h espec. ,0 the proposed devolop.en.. I. Is proposed ,o construe, a 10-unlt resident eve op.en. of the subject site. Other l„ents will comprise of concrete a^ asphalt pavement areas. Site Des^rjp^ir>n The subject project Is situated within a residential/commercial tract at the northwest corner of Christiansen Way and Carisbad Bouleva^, in the City of Cadsbad The lu gene 3haped elongated in a north to south direction. The site Is relatively w.th topography descending gradually from west to east of a few feet. The property contains several singie-famlly residences with associated ln,prove,.ents. The open areas Of the site are covered with a heavy growth of vegetation with the exception of the properly immediately along Carisbad Boulevard. Field lnvoj;till?t|'7n looTT't" °' °' °n April ,3 000 an six 6, additional borings performed on August 8. 2000 to a maximum depth oi 1^ Tl:' visually c.ss,.ed and logged by a «eld engineer with locations of the subsurface explorations Shown on the attached Site Plan. The exploratory excavations revealed the exisZ ea«h matenals to consist o, a „ll and native soii. A detailed description o 1 Fill: A fill soil to a depth of 1 to 3 feet was encountered consisting predominately of a brown, fine to medium grained, slightly silty SAND which was noted generally to be loose to dense and dry to damp. These soils were noted to contain some small gravel, vegetation and root structures. NorCal Engineering April 8, 2002 Page 3 Project Number 8710-00 Natural: An undisturbed native matenal was encountered directly beneath the upper fill soils consisting predominately of a brown to red brown, fine to medium grained, slightiy silty SAND which were noted to be dense and moist. Deeper soils consisted of dense to very dense sands to silty sands. The overall engineenng characenstlcs of the earth materia, were relatively unlfom, with each.^^^^^^^^^^^ Laboratory jacrfc; -ches. BulK bag samples were obtained In the upper soils for expansion Index tests A. The field moisture content (ASTM:D 2216) and the dry density cf .he ring B. Maximum densl^, .ests (ASTM: D-,557-00, were performed on .yplcai samples of the upper soils. Results of these tests are shown on TabieT Expansion index tests in accordance with the Uniform Building Code St n ard No. 29-2 were performed on remolded samples of the uppe o„s 0 determine the expansive characteristics. Results of these tests arl provided on Table II. NorCal Engineering c. April 8, 2002 Page 4 Project Number 8710-00 D. Determination of Atterberg limits (ASTM: D 4318-84) consisting of liquid limit, plastic limit and plasticity index of soils were performed on representative samples. Results are shown on Table 111 E. Soluble sulfate tests in accordance with EPA Method 9038 were performed on representative soils samples. Results are provided in Table IV. F. Direct shear tests (ASTM: D-3080) were performed on undisturbed and disturbed samples of the subsurface soils. The test is performed under saturated conditions at loads of 500 Ibs./sq.ft., 1,000 Ibs./sq.ft., and 2,000 Ibs./sq.ft. with results shown on Plate A. G. Consolidation tests (ASTM: D-2435) were performed on undisturbed samples to determine the differential and total settlement which may be anticipated based upon the proposed loads. Water was added to the samples at a surcharge of one KSF and the settlement curves are plotted on Plate B. Conclusions and Recommendation*; Based upon our evaluations, the proposed development is acceptable from a geotechnical engineering standpoint. By following the recommendations and guidelines set forth in our report, the structures will be safe from excessive settlements under the anticipated design loadings and conditions. The proposed development shall meet all requirements of the City Building Ordinance and will not impose any adverse effect on existing adjacent structures. It is recommended that site inspections be performed by a representative of this firm during all grading and construction of the development to verify the findings and recommendations documented in this report. The following sections present a discussion of geotechnical related requirements for specific design recommendafions of different aspects of the project. NorCal Engineering April 8, 2002 Page 5 Project Number 8710-00 Seismicity Evaluation There are no known active or potentially active faults trending toward or through the site. The proposed development lies outside of any Alquist Priolo Special Studies Zone and the potential for damage due to direct fault rupture is considered very remote. The site is located in an area of high regional seismicity and a peak horizontal ground acceleration of 0.45g may occur from a Magnitude 6.9 earthquake along the fault zone, which is located approximately 4 miles away. Ground shaking originating from earthquakes along other active faults in the region is expected to induce lower horizontal accelerations due to smaller anticipated earthquakes and/or greater distances to other faults. The following earthquake design parameters are based upon the 1997 Uniform Building Code (UBC) for a Seismic Zone 4 with a Z factor of 0.40 and a Soil Profile Type of SD, based on a stiff soil profile. 1997 UBC Seismic Design Parameters Distance from Site (Rose Canyon Fault) Seismic Source Type Seismic Coefficient = Ca (Table 16-Q) Seismic Coefficient = Cv (Table 16-R) Near-Source Factor Na (Table 16-S) Near-Source Factor Nv (Table 16-T) 7 km B (0.44) Na (0.64) Nv 1.0 1.2 Site Grading Recommendations Any vegetation or demolition debris shall be removed and hauled from proposed grading areas prior to the start of grading operations. Any removed soils may be reufilized as compacted fill once any deleterious material or oversized materials (in excess of eight inches) is removed. All grading operations shall be performed in accordance with the attached "Specifications for Placement of Compacted Fill". NorCal Engineering April 8, 2002 ^^9® 6 Project Number 8710-00 The upper disturbed/fill soils (upper 1 to foot^ ^ „ u .he exposed surface shall bi sr^t fd pt^^ "^^^^^^^^^^ moisture content and compacted to » '° P'°P^' lemporary Fv>^^yp|j^r)- rrirr:^: - - ^ - ^^^^ Temporary unsurcharged exlar r:: ^17. -^'^ (horizontal to vertical, gradient, in areas whr i^wir r '' ^'° ' encountered, where adverse geological condLion: a: xZe t wl" are adjacent to existino strurfi.roc ^ • '''^ ^^^P^^^d-or where excavations 'opulred. The tem rl;"ttpe gtdT'i ^""^^^ ^« Sloughing. ' 8'™" P^^^'-e local raveling and adequate lateral suppon for ail adiac.„, • ^'"'^i" .he ..ding operatic: anrcr:::^^^^^^^ ^^ ^' ^" Founription n^<;irjp e::r:z^ - -d. of .000 pst .or an -ThebealgvalrbltrZ^r^^^^^^^ in excess of the 18 inch minimum depth uo IT ' NorCal Engineering April 8, 2002 Project Number 8710-00 Page 7 Lateral Resistance The following values may be utilized in resisting lateral loads imposed on the structure. Requirements of the current Uniform Building Code should be adhered to when the coefficient of friction and passive pressures are combined: Coefficient of Friction - 0.40 Equivalent Passive Fluid Pressure = 250 Ib./cu.ft. Maximum Passive Pressure = 2,500 Ibs./sq.ft. The passive pressure recommendations are valid only for compacted fill soils and/or competent native soils. Settlement Analysis Resultant pressure curves for the consolidation tests are shown on Plate B. Computations ufilizing these curves and the recommended safe bearing capacifies reveal that the foundafions will experience settlements on the order of VA inch and differenfial settlements of less than % inch. Retaining Wall Design Parameters Active earth pressures against retaining walls will be equal to the pressures developed by the following fiuid densifies. These values are for granular free draining backfill material placed adjacent to the walls at various ground slopes above the walls. Surface Slope of Retained Materials Equivalent Fluid (Horizontal to Vertical) Densitv (\h.lcu.n ) Level 30 5 to 1 35 4 to 1 38 3 to 1 40 2 to 1 45 Any applicable short-term construcfion surcharges and seismic forces should be added to the above lateral pressure values. A backfill zone of non-expansive material shall consist of a wedge beginning a minimum of one horizontal foot from the base of the wall extending upward at an inclinafion no less than 1/4 to 1 (horizontal to vertical). All walls shall be waterproofed as needed and protected from hydrostatic pressure by a reliable permanent subdrain system. NorCal Engineering April 8, 2002 Project Number 8710-00 Page 8 Slab Recommendations All concrete slabs shall be a minimum of four inches in thickness and placed on approved subgrade soils. A vapor barrier sandwiched between four inches of select sand shall be ufilized beneath floor slabs which would be sensifive to the infiltration of moisture. All concrete slab areas to receive floor coverings should be moisture tested to meet all manufacturer requirements prior to placement. Corrosion Design Criteria Representative samples of the surficial soils, typical of the subgrade soils expected to be encountered within foundation excavations were tested for sulfate concentration. According to the '1994 Uniform Building Code (UBC) Table 19-A-3 - Requirements for Concrete Exposed to Sulfate-Containing Solutions', these contents revealed negligible levels of sulfate exposure. Therefore, a Type 11 cement according to latest UBC specifications may be utilized for building foundafions at this time. Addifional sulfate tests shall be performed at the completion of rough grading to assure that these soils are consistent with the recommendations stated in this design. Sulfate test results may be found on the attached Table IV. Limitations The recommendafions and conclusions contained in this report are based upon the soil conditions uncovered in our test excavations. No warranty of the soil condition between our excavations is implied. NorCal Engineering should be notified for possible further recommendafions if unexpected to unfavorable conditions are encountered during construction phase. NorCal Engineering April 8, 2002 Project Number 8710-00 Page 9 Any unusual conditions which may be encountered in the course of the project development may require the need for additional study and revised recommendations. It is the responsibility of the owner to ensure that all information within this report is submitted to the Architect and appropriate Engineers for the project. This firm should have the opportunity to review the final plans to verify that all our recommendations are incorporated. This report and all conclusions are subject to the review of the controlling authorities for the project. A preconstruction conference should be held between the developer, general contractor, grading contractor, city inspector, architect, and geotechnical engineer to clarify any questions relafing to the grading operations and subsequent construcfion. Our representative should be present during the grading operations and construction phase to certify that such recommendations are complied within the field. This geotechnical invesfigation has been conducted in a manner consistent with the level of care and skill exercised by members of our profession currently pracficing under similar conditions in the Southern California area. No other warranty, expressed or implied is made. NorCal Engineering April 8, 2002 Project Number 8710-00 Page 10 SPECIFICATIONS FOR PLACEMENT OF COMPACTED FILL Preparation Any exisfing low density soils and/or saturated soils shall be removed to competent natural soil under the inspecfion of the Soils Engineering Firm. After the exposed surface has been cleansed of debris and/or vegetation, it shall be scarified unfil it is uniform in consistency, brought to the proper moisture content and compacted to a minimum of 90% relafive compaction (in accordance with ASTM: D-1557-00). Material For Fill The on-site soils or approved import soils may be utilized for the compacted fill provided they are free of any deleterious materials and shall not contain any rocks, brick, asphalfic concrete, concrete or other hard materials greater than eight inches in maximum dimensions. Any import soil must be approved by the Soils Engineering firm a minimum of 24 hours prior to importafion of site. Placement of Compacted Fill Soils The approved fill soils shall be placed in layers not in excess of six inches in thickness. Each lift shall be uniform in thickness and thoroughly blended. The fill soils shall be brought to within 15% of the opfimum moisture content, unless otherwise specified by the Soils Engineering firm. Each lift shall be compacted to a minimum of 90% relative compaction (in accordance with ASTM: D-1557-00) and approved prior to the placement of the next layer of soil. Compaction tests shall be obtained at the discretion of the Soils Engineering firm but at a minimum of one test for every 500 cubic yards placed and/or for every two vertical feet of compacted fill placed. NorCal Engineering April 8, 2002 Project Number 8710-00 Page 11 The minimum relafive compacfion shall be obtained in accordance with accepted methods in the construction industry. The final grade of the structural areas shall be in a dense and smooth condition prior to placement of slabs-on-grade or pavement. No fill soils shall be placed, spread or compacted during unfavorable weather condifions. When the grading is interrupted by heavy rains, compacfion operations shall not be resumed unfil approved by the Soils Engineering firm. Grading Observations The controlling governmental agencies should be nofified prior to commencement of any grading operafions. This firm recommends that the grading operations be conducted under the observafion of a Soils Engineering firm as deemed necessary. A 24 hour nofice must be provided to this firm prior to the fime of our inifial inspecfion. Observafion shall include the clearing and grubbing operafions to assure that all unsuitable materials have been properly removed; approval of the exposed subgrade in areas to receive fill and in areas where excavation has resulted in the desired finished grade and designate areas of overexcavation; and performance of field compaction tests to determine relafive compacfion achieved during fill placement. In addition, all foundafion excavafions shall be observed by the Soils Engineering firm to confirm that appropriate bearing materials are present at the design grades and recommend any modifications to construct foofings. NorCal Engineering WASHIN6TON STREET CARLSBAD BOULEVARD 1 INCH = 100 FEET NorCal Engineering SOILS AND GEOTECHNICAL CONSULTANTS SITE PLAN APPROXIMATE LOCATION OF FIELD EXPLORATIONS THE VILLAGE BY THE SEA SITE PLAN APPROXIMATE LOCATION OF FIELD EXPLORATIONS PROJECT 8710-00 | DATE APRIL 2002 SITE PLAN APPROXIMATE LOCATION OF FIELD EXPLORATIONS Appendices (In order of appearance) Appendix A - Log of Excavations Logs of Borings Bl to 812 Appendix B - Laboratory Tests Table I - Maximum Dry Density Tests Table II - Expansion Index Tests Table III - Atterberg Limits Table IV - Sulfate Tests Plate A - Direct Shear Tests Plate B - Consolidation Tests NorCal Engineering Appendix A NorCal Engineering r MAJOR DIVISION GRAPHIC SYMBOL LETTER SYMBOL TYPICAL DESCRIPTIONS COARSE GRAINED SOILS MORE THAN 50% OF MATERIAL IS LARGER THAN NO. 200 SIEVE SIZE GRAVEL AND GRAVELLY SOILS MORE THAN 50% OF COARSE FRACTION RETAINED ON NO. 4 SIEVE SAND AND SANDY SOILS MORE THAN 50% OF COARSE FRACTION PASSING ON NO. 4 SIEVE CLEAN GRAVELS (LITTLE OR NO FINES) o Oo GW WELL-GRADED GRAVELS, GRAVEL. SAND MIXTURES, LITTLE OR NO FINE GP POORLY-GRADED GRAVELS. GRAVEL-SAND MIXTURES, LITTLE OR NO FINES GRAVELS WITH FINES (APPRECIABLE AMOUNT OF FINES) GM SILTY GRAVELS, GRAVEL-SAND- SILT MIXTURES GC CLAYEY GRAVELS, GRAVEL-SAND- CLAY MIXTURES CLEAN SAND (LITTLE OR NO FINES) SW WELL-GRADED SANDS. GRAVELLY SANDS, LITTLE OR NO FINES SP POORLY-GRADED SANDS, GRAVEL- LY SANDS. LITTLE OR NO FINES SANDS WITH FINE (APPRECIABLE AMOUNT OF FINES) SM SILTY SANDS, SAND-SILT MIXTURES SC CLAYEY SANDS, SAND-CLAY MIXTURES ML INORGANIC SILTS AND VERY FINE SANDS, ROCK JLOUR, SILTY OR CLAYEY FINE SANDS OR CLAYER SILTS WITH SLIGHT PLASTICITY FINE GRAINED SOILS SILTS AND CLAYS LIQUID LIMIT LESS THAN 50 CL MORE THAN 50% OF MATERIAL IS SMALLER THAN NO. 200 SIEVE SIZE SILTS AND CLAYS LIQUID LIMIT GREATER THAN 50 INORGANIC CLAYS OF LOW TO MEDIUM PLASTICITY, GRAVELLY CLAYS, SANDY CLAYS, SILTY CLAYS, LEAN CLAYS OL ORGANIC SILTS AND ORGANIC SILTY CLAYS OF LOW PLASTICITY MH INORGANIC SILTS, MICACEOUS OR DIATOMACEOUS FINE SAND OR SILTY SOILS CH INORGANIC CLAYS OF HIGH PLASTICITY, FAT CLAYS OH ORGANIC CLAYS OF MEDIUM TO HIGH PLASTICITY, ORGANIC SILTS HIGHLY ORGANIC SOILS PT PEAT, HUMUS, SWAMP SOILS WITH HIGH ORGANIC CONTENTS NOTE: DUAL SYMBOLS ARE USED TO INDICATE BORDERLINE SOIL CLASSIFICATIONS UNIFIED SOIL CLASSIFICATION SYSTEM orCal Engineering KEY: m c a IX Indicates 2.5-inch Inside Diameter. Ring Sample. Indicates 2-incli OD Split Spoon Sample (SPT). Indicates Slielby Tube Sample. Indicates No Recovery. Indicates SPT with 140# Hammer 30 in. Drop. Indicates Bulk Sample. Indicates Small Bag Sample. Indicates Non-Standard Indicates Core Run. COMPONENT PROPORTIONS COMPONENT DEFINITIONS COMPONENT SIZE RANGE Boulders Cobbles Gravel Coarse gravel Fine gravel Sand Coarse sand Medium sand Fine sand Silt and Clay Larger than 12 in 3 in to 12 in 3 in to No 4 (4.5mm ) 3 in to 3/4 in 3/4 in to No 4 ( 4.5mm ) No. 4 ( 4.5mm ) to No. 200 ( 0.074mm ) No. 4 ( 4.5 mm ) to No. 10 ( 2.0 mm ) No. 10 ( 2.0 mm ) to No. 40 ( 0.42 mm ) No. 40 ( 0.42 mm ) to No. 200 ( 0.074 mm ) Smaller ttian No. 200 ( 0.074 mm ) DESCRIPTIVE TERMS RANGE OF PROPORTION Trace 1 - 5% Few 5-10% Little 10-20% Some 20 - 35% And 35 - 50% MOISTURE CONTENT DRY Absence of moisture, dusty, dry to the touch. DAMP Some perceptible moisture; below optimum MOIST No visible water; near optimum moisture content WET Visible free water, usually soil is below water table. RELATIVE DENSITY OR CONSISTENCY VERSUS SPT N -VALUE COHESIONLESS SOILS COHESIVE SOILS Density N (blows/ft) Consistency N (blovre/ft) Approximate Undrained Shear Strength (psf) Very Loose Loose Medium Dense Dense Very Dense 0to4 4 to 10 10 to 30 30 to 50 over 50 Very Soft Soft Medium Stiff Stiff Very Stiff Hard 0to2 2 to 4 4 to 8 8 to 15 15 to 30 over 30 <250 250 - 500 500-1000 1000-2000 2000 - 4000 >4000 NorCal Engineering Log of Boring B-1 Project: Anastasi/Carlsbad Date of Drilling: 4/13/00 Groundwater Depth: None Encountered Drilling Method: Hand Auger Hammer Weight: Drop: Geotechnical Description Surface Elevation: Not Measured FILL SOILS SAND fine to medium grained slightly silty \Brown, loose, damp with small gravel, upper 6" with small rootlets NATURAL SOILS SAND fine to medium grained slightly silty Brown to red/brown, dense to very dense, damp SAND fine to medium grained Light brown, medium dense, damp Boring completed at depth of 15' •—— Lith-ology Samples « a >• (A O 3 CD O Laboratory 3^ "5 4.5 6.7 4.0 2.9 115.4 116.7 111.7 106.1 in NorCal Engineering Project No. 8710-00 Log of Boring B-2 Anastasi/Carlsbad Date of Drilling: 4/13/00 Groundwater Depth: None Encountered Drilling Method: Hand Auger Hammer Weight: Drop: Geotechnical Description Surface Elevation: Not Measured Lith-ology Samples (A O 3 Laboratory 3^ "5 10 15 20 25 FILL SOILS SAND fine to medium grained slightly silty \Brown, loose, damp with small gravel, upper 6" w|th small rootlets NATURALSOILS " SAND fine to medium grained slightly silty Brown to red/brown, dense to very dense, damp SAND fine to medium grained Light brown, medium dense, damp 7.3 115.9 3.7 107.6 Boring completed at depth of 15' 2.6 109.8 NorCal Engineering Project No. 8710-00 Log of Boring B-3 Project: Anastasi/Carlsbad Date of Drilling: 4/13/00 Groundwater Depth: None Encountered Drilling Method: Hand Auger Hammer Weight: Drop: Geotechnical Description Surface Elevation: Not Measured FILL SOILS ' " SAND fine to medium grained slightly silty , Brown, loose, damp with small gravel, heavy dried vegetation and roots to \2.5' NATURALSOILS SAND fine to medium grained slightly silty Brown to red/brown, dense to very dense, damp SAND fine to medium grained I Light brown, medium dense, damp i Boring completed at depth of 10' Lith-ology 0) Q. >. NorCal Engineering O 3 tn o "ar 3-^ 0 _2 6.8 Project No. 8710-00 116.7 0)' Log of Boring B-4 Project: Anastasi/Carlsbad Date of Drilling: 4/13/00 Groundwater Depth: None Encountered Drilling Method: Hand Auger Hammer Weight: Drop: Samples" Geotechnical Description Surface Elevation: Not Measured Lith-ology (0 O 3 CO Laboratory 3^ ^ Q Ss U) 10 15 FILL SOILS SAND fine to medium grained slightly silty \Brown, loose, damp with small gravel, upper 6" with smalkootlets NATURALSOILS SAND fine to medium grained slightly silty Brown to red/brown, dense to very dense, damp SAND fine to medium grained Light brown, medium dense, damp 5.9 114.6 3.4 110.8 Boring completed at depth of 12' ^^^^ NorCal Engineering Project No. 8710-00 Log of Boring B-5 roject: Anastasi/Carlsbad Date of Drilling: 4/13/00 Groundwater Depth: None Encountered Drilling Method: Hand Auger Hammer Weight: Drop: Geotechnical Description Surface Elevation: Not Measured FILL SOILS \ SAND fine to medium grained slightly silty \ Brown, loose, damp with small gravel and heavy roots and dried .^vegetation NATURALSOILS SAND fine to medium grained slightly silty Brown to red/brown, dense to very dense, damp Boring completed at depth of 8' Lith-ology Samples w O 3 5,^ 3^ 2_ Laboratory 7.8 Q Ss o 112.6 M NorCal Engineering Project No. 8710-00 Log of Boring B-6 Project: Anastasi/Carlsbad Date of Drilling: 4/13/00 Groundwater Depth: None Encountered Drilling Method: Hand Auger Hammer Weight: Drop: Samples Laboratory Geotechnical Description Surface Elevation: Not Measured Lith-ology « a >. I- O 3 CD O T 3^ ^0 Q Ss a in 10 15 20 25 FILL SOILS SAND fine to medium grained slightly silty \Brown, loose, damp with small gravel, upper 18" with small rootlets NATUIRAL SOILS SAND fine to medium grained slightly silty Brown to red/brown, dense to very dense, damp 6.9 112.8 Boring completed at depth of 8' NorCal Engineering Project No. 8710-00 Log of Boring B-7 Anastasi/Carlsbad Date of Drilling: 8/8/00 Groundwater Depth: None Encountered Drilling Method: Hand Auger Hammer Weight: Drop: Samples" Laboratory" Geotechnical Description Surface Elevation: Not Measured Lith-ology in O 3 CO o 1 5^ S. Q Ss 5 10 15 20 25 FILL SOILS Silty SAND with minor debris, loose, dry NATURALSOILS SAND fine to medium grained slightly Silty Brown, dense, dry Boring completed at depth of 5' 2.7 113.6 NorCal Engineering Project No. 8710-00 Log of Boring B-8 Anastasi/Carlsbad Date of Drilling: 8/8/00 Groundwater Depth: None Encountered Drilling Method: Hand Auger Hammer Weight: Drop: Samples Laboratory Geotechnical Description Surface Elevation: Not Measured Lith-ology 10 O 3 3^ o J2_ ° Ss Q M FILL SOILS Silty SAND with minor debris, loose, dry NATURALSOILS SAND fine to medium grained slightly Silty Brown, dense, dry 2.4 116.2 Boring completed at depth of 8' NorCal Engineering Project No. 8710-00 Log of Boring B-9 Project: Anastasi/Carlsbad Date of Drilling: 8/8/00 Groundwater Depth: None Encountered Drilling Method: Hand Auger Hammer Weight: Drop: 10 15 20 25 Geotechnical Description Surface Elevation: Not Measured FILL SOILS Silty SAND Brown, dense to very dense, dry NATURAL SOILS SAND fine to medium grained slightly Silty Brown to red brown, dense to very dense, dry SAND fine to medium grained Light brown, medium dense, damp Boring completed at depth of 10' Lith-ology Samples in O 3 00,9 Laboratory 3-» 2.8 5.1 Q Ss O 113.6 110.9 in NorCal Engineering Project No. 8710-00 Log of Boirng B-10 Project: Anastasi/Carlsbad Date of Drilling: 8/8/00 Drilling Method: Hand Auger Hammer Weight: Groundwater Depth: None Encountered Drop: }epth [feet) Geotechnical Description 0 Surface Elevation: Not Measured FILL SOILS Silty SAND Brown, dense to very dense, dry NATURAL SOILS SAND fine to medium grained slightly Silty Brown to red brown, dense to very dense, dry Boring complete(Jat depth of 5' 10 Lith-ology 15 20 25 Samples M O 3 1 3^ o"^ 2_ Laboratory ^52 Q Ss o M NorCal Engineering Project No. 8710-00 10 Log of Boirng B-11 Project: Anastasi/Carlsbad Date of Drilling: 8/8/00 Groundwater Depth: None Encountered Drilling Method: Hand Auger Hammer Weight: Drop: 10 15 20 |25 Geotechnical Description Surface Elevation: Not Measured FILL SOILS Silty SAND Brown, dense to very dense, dry NATURAL SOILS SAND fine to medium grained slightly Silty Brown to red brown, dense to very dense, dry SAND fine to medium grained Light brown, medium dense, damp Boring completed at depth of 12' Lith-ology Samples « a >> I- M O 3 Laboratory 3^ 5 2_ 2.3 4.6 Q Ss 114.6 115.6 in NorCal Engineering Project No. 8710-00 11 Log of Boring B-12 Project: Anastasi/Carlsbad Date of Drilling: 8/8/00 Groundwater Depth: None Encountered Drilling Method: Hand Auger Hammer Weight: Drop: epth feet) Geotechnical Description 0 Surface Elevation: Not Measured FILL SOILS Silty SAND \Brown, dense to very dense, dry NATURAL SOILS SAND fine to medium grained slightly Silty Brown to red brown, dense to very dense, dry Boring completed at depth of 8' 10 15 20 25 Lith-ology « a Samples O 3 5 ° 3^ 'o'~^ Laboratoiry" Q Ss 1.1 M NorCal Engineering Project No. 8710-00 12 Appendiy R NorCal Engineering April 8, 2002 Page 12 Project Number 8710-00 TABLE I MAXIMUM DENSITY TESTS (ASTM: D-1557-00) Sample Classification Bl @ 1-2' SAND, fine to medium grained, slightly silty B^2@0-V silty SAND Optimum Moisture 10.5 10.0 Maximum Dry r)fin.sitv (Ibs./cu.ft.) 124.5 126.0 Soil Type Bl @ 1-2' B12@0-1' TABLE 11 EXPANSION INDEX TESTS (U B C. STD. 29-2) Classification SAND, fine to medium grained, sliglitly siity silty SAND Expansion Index 03 05 Sample Bl m 1-4' Liquid Limit 21 TABLE III ATTERBERG LIMITS Plastic Limit 16 Plasticity Index 5 Sample Composite TABLE IV SULFATE TESTS Sulfate (%) 0.019 % by weight NorCal Engineering 500 1000 1500 2000 NOWML STRESS (PSF) 2500 3000 SYMBOL BORING NUMBER DEPTH (FEET) 0 (DEGREES) C (PSF) DRT DENSITY (PCF) MOISTURE coirrENT (X) X 1 2.5 34 125 115.4 4.5 O 2 3.0 37 75 115.9 7.3 A 6 2.0 32 125 112.1 6.9 • NOTE: TESTS PERFORMED ON SATURATED SAMPLES UNLESS SHOWN BELOW. (FM) FIELD MOISTURE TESTS PERFORMED ON UNDISTURBED SAMPLES UNLESS SHOWN BELOW. (R) SAMPLES REMOLDED AT 90t OF MAXIMUM DRY DENSITY NorCal Engineering SOILS AND GEOTECHNICAL CONSULTANTS PROJECT 8710-00 DIRECT SHEAR TEST RESULTS Plate A Plate B DATE