HomeMy WebLinkAboutCT 02-13; FARBER CONDOMINIUMS; UPDATED SOILS REPORT; 2003-09-10I ENGINEERING
DESIGN,GROUP
GEOTECHNICAL, CIVIL, STRUCTURAL A ARCHITECTURAL CONSULTANTS . . . . .
II ..
FOR RESIDENTIAL & COMMERCIAL CONSTRUCTION
2121 Montiel Road San Marcos California 92069 (760)'839-7302 Fax (760) 480-7477 www designgroupca c
1 I
T
Date September 10, 2003
To Farber Family Partnership I
I Attention Curtis Farber j. I 140 Marine View Avenue #220 I
I Solana Beach, CA 92075
Re I Proposed Multi-family Development to Be Located at 1100 Las Flores Drive, I
I City of Carlsbad, California
I
Subject Updated Soils Report
Reference: "GEOTECHNICAL INVESTIGATION AND FOUNDATION RECOMMENDATIONS, FOR
PROPOSED MULTI-FAMILY MULTI-FAMILY DEVELOPMENT, TO BE LOCATED AT 1100 LAS FLORES
II ... . . . ..-
. DRIVE 'CITY OF CARLSBAD CALIFORNIA.", Project No: 002486-1, dated December 22, -,
I
2000 by Engineering Design Group
I GENERAL 1
I
I In accordance with your request, w have reviewed the above referenced Geotechnical I
Investigation report and provided the following updated recommendations for the proposed
development. Our update is based on our review of the above referenced report and site
I.
reconnaissances of the property. Based on our conversations with the project developer -
it is anticipated that the proposed new improvements will consist of the following I
I
> Design and construction of new multi unit condominium complex I
> Partially subterranean parking garage
> Miscellaneous walkway and common area improvements
I
I UPDATE RECONNAISSANCE
I
Representatives of Engineering Design Group visited the subject property on September
9, 2003 and found the condition of the residential property to be generally similar to that
described in our above referenced geotechnical report Based on our site reconnaissance,
Page No. 1 of 8
I
Project No. 002486-1 . .
- - -- - - -. 1 E:\JOBS\1 JOBS\2000\002486.1, FARBER-MULTI-FAMILY DEV, F1100 LAS FLORES DRIVE, CARLSBAD - UPDATE.wpd
I
I4
I ENGINEERING
- 60000CHNICAL, CIVIL, STRUCTURAL V ARCHITECTURAL CONSULTANTS -
1 DESIGN GROUP
.•..
TOO RESIDENTIAL S COMMERCIAL CONSTRUCTION
,.2121 Montiel Road, San Marcos, California 92069. (760) 839-7302 Fax: (760) 480-7477 wwwesigngroupcacom
I
I Date September 10, 2003
I - To: . Farber Family Partnership.
Attention:..Curtis Farber
140 Marine View Avenue #220 I Solana Beach, CA 92075
I Re: i Proposed Multi-family bevelopment to Be Located at 1100 Las Flores Drive,
City of Carlsbad, California
I
Subject Updated Soils Report I
Reference: "GEOTECHNICAL INVESTIGATION AND FOUNDATION RECOMMENDATIONS, FOR
PROPOSED MULTI-FAMILY DEVELOPMENT, TO BE LOCATED AT 1100 LAS FLORES
DRIVE, CITY OF CARLSBAD, CALIFORNIA.", Project No: 002486-1, dated December22,
.2000, by Engineering Design Group. . . . . ..
I GENERAL
I . .
In accordance with your request, we. have reviewed the above referenced Geôtechnical .
Investigation report and provided the following updated recommendations for the proposed
development. Our update is based on our review of.the above referenced report and site
I •.
reconnaissances of the property. Based on our conversations with the project developer .•
it is anticipated that the proposed new Improvements will consist of the following
I
>.. Design and; construction of new multi unit condominium complex ... . .
- Partially subterranean parking garage . . -. .. . . . . . .
Miscellaneous walkway and common area improvements.-
UPDATE RECONNAISSANCE
I
. Representatives of Engineering Design Group visited the.subject property on September
9, 2003 and found the condition of the residential pro perty be generally similar to, that
described in ourabove referenced geotechnical report. Based on our site reconnaissance, .
I
I Page No. 1of8
Project No. 002486-1 f- E:\JOBS\1 JOBS\2000\002486-1, FARBER-MULTI-FAMILY DEV, F1100 LAS FLORES DRIVE, CARLSBAD - UPDATE.wpd
I
i : !
the recommendations of our above referenced report for the property remain pertinent and tw:applicable to the property, with the following amended updates
The building Architect, or waterproofing subcontractor, shall design a retaining wall
and slab waterproofing system to adequately prevent water intrusion into the .
I
subterranean garage per the design expectations of the developer. The details i
pro vi Jed in our referenced report are minimum guidelines only, intended to
addrss hydrostatic buildup issues behind the retaining 'elements Upgraded
1 .
.waterproofing elements' may include FirestoneEPMlinër in.:lieuof visqueen, pea
gravl underlayment in lieu of sand, water retarding admixtures, slab underdrain
systems, surface sealants, etc The design of the subterranean water proofing; '
I
system for this development is beyond the scope of this report
1The fundation section of our report is updated as follows
t .
I I I FOUNDATIONS ""-
1- Footings bearing in competent formational materials or compacted and
certified fill maybe designed utilizing maximum allowable soils pressure of
2,000 psf,
I 2 Seismic Design Parameters I
P'k. of Floors
Supported
M!niPnum Fo&tkig Width *Mjnj, Feoti/gepth
Below Lowest Adjacent Grade
1. 18 inches 18 inches
2 18inch0s 18 inches
3 18incjjs 24inphe,,
4
...
...
.
............
All footings should be reinforced with a minimum of two #5 bars at the
and two #5 bars at the bottom (3 inches above the ground). For footings
over 30 inches in depth,, additional reinforcement, and possibly a stemwall ,
system will be necessary.,This detail should be reviewed on a case by case
I basis by our office prior to construction ,.
5 All isolated spread footings should be "designed utilizing the above given
1
bearing values and footing depths, and be reinforced with a minimum of #5 1,..
. .
.
bars at 12 inches o c in each direction (3 inches above the ground)
Isolated spread footings should have a minimum width of 24 inches
I 6 For footings (including site\retaining wall footings) and all other cosmetically
- sensitive improvements adjacent to slopes, a minimum 12 feet horizontal
I " setback in formational or certified . fill material should be maintained. A
setback measurement should be taken at the horizontal distance from the
bottom of the footing or improvement to slope• daylight. Where . this. ,. .
. . condition can not be met , it should be brought to the attention of the ;.
Engineering Design Group for review. .. . '.
I. ¼ 7. All excavations should be performed in general accordance with the content&L . .
of this report, applicable codes, OSHA requirements and applicable city
.and/or countystandards. . . . . . . . . . .
. I 8. 1 Al! foundation sub grade soils and footings shall be pre-moistened aminimum . ..: •
of 18 inches in depth prior to the pouring of concrete.
I........ .. . • 9. Concrete for building foundations should have a minimum compressive
It strength of 2,500 psi in 28 days. . . . . .. :
¼
I
I
I . . . . . . .
.. Page No. 3 of 8 i
. .
I
Project No. 002486-1
E:\JOBS\l .JOBS\2000\002486-1, FARBER-MULTI-FAMILY 0EV Fl 100 LAS FLORES DRIVE, CARLSBAD. UPDATE.wpd
I
1' S
.
The concrete slabs ection of our report is updated as follows
CONCRETE SLABS ON GRADE ..
..
.
1. Concrete slabs on grade of the garage should have a minimum thickness of
5 inches (6 inches at garage and driveway locations) and should be
reinforced with #4 bars at 18.inches o.c. placed at the midpointof the slab.
All concrete shall be poured per the following:
Slump: Between .3 and 4 inches maximum ,
Aggregate Size: 3/4 - 1 inch' " • j. .,
Air Content: 5 to 8 percent . .
Moisture retarding additive in concrete at moisture sensitive areas.
Water to cement Ratio '- 0.5 maximum ,.
All required fills used to support slabs, should be placed in accordance with
the grading section of this. reptht and," the' attached Appendix B, and
compacted to 90 percent Modified ProctdrDensity, ASTM D-1557.. '
. A uniform layer of 4 inches of clean sand is recommended under the slab in.•
order to more uniformly support the slab, help distribute loads to the soils
beneath the slab, and act as a capillary break. In addition, a vis queen layer
(10 mil' should be placed mid-height in the sand bed to act as a vapor
retarder. As an upgrade, an Firestone EPM liner may be used. instead of .'
visqueen
".Adequate control joints should be installed to control the unavoidable ,
I cracking of concrete that takes place when undergoing.its natural shrinkage.
during curing. The controljoints should be well located to direct unavoidable'
slab cracking to areas that are desirable by the designer. . . . ., .;.
: 'All sub grade soils'. to receive concrete flatwork are to be pre-soaked to. 2
percent over optimum moisture content to a depth of 18 inches. . . '.
Brittle floor finishes placed, directly on slab .on grade floors may crack if
concrete is not adequately cured prior, to installing the finish or if there is
minor slab movement. To minimize potential damage to movement sensitive
flooring, we recommend the use of slip sheeting techniques (linoleum type)
which allows for foundation and slab movement without transmitting .this
movement to the floor finishes.
4 • ,.,.
1' ... . Page No. 40f8
Project No. 002486-1
E:\JOBS\1 JOBS\2000\002486-1, FARBER-MULTI-FAMILY DEV, F1100 LAS FLORES DRIVE, CARLSBAD - UPDATE.wpd
'.5- 5 '''
• I'
I •. S 5,...
Prior to placement of any moisture sensitive floor finishes, the flooring
contractor shall conduct vapor emission testing, per ASTM standards, to 1 determine the suitability of the concrete for the proposed flooring type.
Where emission rates exceed the. manufactures specifications, a concrete.
I .. sealant product shall be utilized. .
7. Exterior concrete flatwork and driveway slabs, due to the nature of concrete
I hydration and minor sub grade soil movement, are subject to normal minor
concrete cracking. To minimize expected concrete cracking, the following
may be implemented:
.
I 0 Concrete slump should not exceed 4 inOhes. :
Concrete should be poured during "cool" (40 - 65, degrees) weather
if possible. If concrete is poured in hotter weather, a set retarding.. I additive should be included in the mix, and the slump kept tb a
minimum.
Concrete sub grade should be pre-soaked prior to the pouring of
concrete. The level of pre-soaking should be a minimum of 2% over
optimum moisture to a depth of 18 inches.
Concrete may be poured with a 10 inch deep thickened edge. I • Concrete should be constructed with tooled joints or sawcuts (1 inch
deep) creating concrete sections no larger than 225 square feet. For
sidewalks, the maximum run between joints should not exceed 5 feet. ' I . For rectangular shapes of concrete, the ratio of length to width should
. generally not exceed 0.6 (i.e., 5 ft. long by 3 ft. wide). Joints should
be cut at expected points of concrete shrinkage (such as male
I corners), with diagonal reinforcement placed in accordance with
industry standards. .
Drainage adjacent to concrete flatwork should direct water away from
I . the improvement. Concrete subgrade should be sloped and directed...
. . : to the collective drainage system, such that water is not trapped
below the flatwork. . .
I . The recommendations set forth herein are intended to reduce
cosmetic nuisance cracking but will not prevent concrete
cracking. The owner should be aware all concrete, because of it's
I cementitious nature, will to some degree shrink and crack. The
amount, location and impact on the cosmetic finish, of cracking can
be reduced by design philosophy and construction. The project
, I concrete contractor is ultimately responsible for concrete quality and '
• .. performance, and should pursue a cost-benefit analysis of these
recommendations with the owner & general contractor, and other
1 options available in the 'industry, prior to the 'pouring of concrete.
I .
• Page No. 5of8
Project No. 002486-1 E:UOBS\1 JOBS\2000\002486-1, FARBER-MULTI-FAMILY DEV, Fl 100 LAS FLORES DRIVE, CARLSBAD - UPDATE.wpd
I
I Additionally, the project owner should be made fully aware of
expected performance of concrete. finishes, so as to avoid follow up
calls regarding minor concrete cracking
II) The retaining wall section of our report is updated as follows
RETAINING WALLS: . •. ..
.
I Retaining walls up to 8 feet may be designed and constructed in accordance with
the fdllowing recommendations and minimum design parameters
1 1. Retaining wall footings should be designed in'acóordañcè with.the allowable
. bearing criteria given in the "Foundations" section of this report, and should
maintain minimum footing depths outlined in "Foundation" section of this
1 I report
. 2. Unrestrained cantilever retaining Walls should be designed using ana ctive' I . equivalent fluid pressure 0f35pcf This assumes that granular, free drainin:
material will be used for backfill, and that the backfill surface will be level.
For sloping backfill, the following parameters may be utilized:
Backfill Sloping . 2:1 Slope , ' 1.5:1 Slope
Condition ' .'.
.
.. .. ..
Active Fluid 50 pcf ' ' 65 pcf
Pressure
I
, Any other surcharge loadings shall be analyzed in addition to the above values.
I 3 If the tops of retaining walls are restrained from movement, they should be
designed for a uniform soil pressure of 65 psf.
I . 4. Passive soil resistance maybe calculated using an equivalent fluid pressure
of 300 pcf.. This value assumes that the soil being utilized to resist passive '
I • . .
pressures, extends horizontally 2.5 times the height of the passive pressure
wedge of the soil. Where the horizontal distance of the. available passive L
pressure wedge is less than 2.5 times the height, of .the soil, the passive
pressure value must be reduced by the percent reduction in available I ' '. •
horizontal length.. . . . • '
5. A coefficient of friction of 0.35 betWeen the soil and concrete footings may I •,
":-.be 'utilized to resist lateral loads in addition to the passive earth pressures
above. . , .' •• ' .
I . . • . ' Page No. 60f8
. Project No. 002486-1
. E:\JOBS\1 JOBS\2000\002486-1, FARBER-MULTI-FAMILY DEV, Fl 100 LAS FLORES DRIVE, CARLSBAD - UPDATE.WPd
I ' • ,
• •'. .
S
,
•.
It
I I
I
6. Retaining walls should be braced and.monitored during compaction. If this
cannot be accomplished, the compà'ótive' effort should be included as a
.
surcharge load when designing the wall.
7. . Al/walls shall be provided with adequate back drainage to relieve hydrostatic
'pressure, and be designed in accordance with the minimum standards
I
contained in the "Retaining Wall Drainage Detail", Appendix D Area drains
-i: should not be connected to French Drain System behind retaining wall. Wall
' waterproofing systems shall be designed by the building Architect.
1 8 Retaining wall backfill should be placed and compacted in accordance with
the "Earthwork" section• of this, report. Backfill shall consist of a non-c'
I
expansive granular, free draining material
IV) The construction observation and testing section of our report is updated as follows: ,
CONSTRUCTION OBSERVATION AND TESTING . ..
The recommendations provided in this report are based on subsurface conditions,
our review of the site, and knowledge of the area. Interpolated subsurface
conditions must be verified in the field during construction; The following items shall
be conducted.prior/during construction by a representative of Engineering Design
Group (under separate contract) in order to verify compliance, with the geotechnical
and civil engineering recommendations provided herein, as applicable.. S
Review of final project grading and foundation plans prior to construction.
f Attendance of a pre-grade/pre-construction meeting prior to the . .start of:
construction. . . . . 3.' . Observation of removal bottom.'park!ng garage subgrade,. .• '
4 ..' Observation and testing, of any fill placement, including utility trenches and
. '.retaining wall backfill. • . I ...
5. Final review of onsite drainage systems.'. • . . ...
The 'project soils engineer may at their discretion deepen footings or 'locally:
recommend additional steel reinforcement to upgrade any condition as deemed
'necessary during site observations. . .
The field inspection protocol, as outlined above, is a requirement of this report.
Engineering Design Group assumes no liability for structures constructed utilizing
this report not 'meeting.this protocol. In the event field inspection work is conducted
by others, they shall assume sole responsibility for work conducted and certilfy the
suitability of soils for building support. • . .'
• S
• ..........
. "' • ' . . Page No. 7 of 8
S , ' Project No. 002486-1
E:\JOBS\1 JOBS\2000\002486-1, FARBER-MULTI-FAMILY DEV, Fl 100 LAS FLORES DRIVE, CARLSBAD - UPDATE.wpd
-. -
-
I . If you have any questions, regarding this report, or.ifwe can be of further service, please
do not hesitate to 'co ntactus. We hope the report provides you with necessary information
to continue with the development of the project.
<0 263
6) CERTIFIED co C 7672 ca 2590 7- EERING
California RCE #47672 r
Sincer GE
I
I:
I P
I
I I Page No. 8 of 8 1 - Project No. 002486-1 E:\JOBS\1 JOBS2000\002486-1, FARBER-MULTI-FAMILY 0EV, Fl 100 LAS FLORES DRIVE, CARLSBAD - UPDATEwpd
I: