HomeMy WebLinkAboutCT 02-28; LA COSTA CONDOMINIUMS; LANDSIDE STABILIZATION; 2008-04-29American GeotechnicaUnc
SOIL, FOUNDATION AND GEOLOGIC STUDIES
April 29, 2008 File No. 23080-01R
City of Carlsbad - Public Works
1635 Faraday Avenue
Carlsbad, CA 92008
Attention: Mr. Steve Bobbett
Subject: RESPONSE TO THIRD-PARTY REVIEW
LANDSLIDE STABILIZATION
Banich, Powers, and Calso Landslide
Carlsbad, California
Reference: THIRD-PARTY REVIEW OF CONSTRUCTION REVISION
By: Bureau Veritas North America, Inc.
Dated: Apirl 9, 2008
Dear Mr. Bobbett:
We are in receipt ofthe third-party review ofthe landslide stabilization forthe Banich, Powers, and
Calso Landslide, Carlsbad, California. In Appendix A, we have reproduced the third-party review by
Bureau Veritas North America, Inc.
In response to their comment, we have reproduced our gross slope stability analyses in Appendix B.
This gross slope stability analyses is reproduced from Appendix C of our report dated March 27, 2007.
As our gross slope stability analyses shows, we assumed that the upper part of the slope would be re-
built to approximately pre-failure conditions. We utilized an upper slope inclination of 37 degrees,
which is essentially a 1.3:1.0 (horizontahvertical) slope ratio. Please also note that the gross slope
stability analyses indicates a factor of safety of 1.612 (Bishop Method) and this factor of safety does not
include the stabilizing effect ofthe three, upper tie back walls and the proposed geogrid in the upper
part of the slope. Hence, we have used a conservative gross slope stability analyses by not including
the stabilizing effect of the upper tie back walls and the presence of geogrid, and yet the gross factor of
safety is still in excess of 1.5. Thus, it is our opinion that the final constructed condition ofthe re-built
slope, which includes the tieback walls and geogrid, will have a gross factor of safety in excess of 1.5.
22725 Old Canal Road, Yorba Linda, CA 92887 • (714) 685-3900 • FAX (714) 685-3909
5600 Spring Mountain Road, Suite 201, Las Vegas, NV 89146 • (702) 562-5046 • FAX (702) 562-2457
5764 Pacific Center Blvd., Suite 112, San Diego, CA 92121 • (858) 450-4040 • FAX (858) 457-0814
712 Fifth Street, Suite #B, Davis, CA 95616 • (530) 758-2088 • FAX (530) 758-3288
File No. 23080-01R
April 29, 2008
Page 2
liAmerican Geotechnical, Inc.
We appreciate the opportunity to be of service. If you should have any questions or concerns, please
do not hesitate to contact our office.
Respectfully submitted,
AMERICAN GEOTECHNICAL, INC.
igory/W. Axten
PTssident/CEO
G.E. 103
GWA: dd
Enclosures: Appendix A - Third Party Review
Appendix B - Gross Slope Stability Analyses
Distribution: 3 - Mr. John Strohminger (Overnight)
O'Day Consultants, 2710 Loker Ave. West, Carlsbad, CA 92010
1 - Mr. Bob Day (Regular Mail & Email: davb@amqt.com)
American Geotechnical, Inc.
wpdata/20000/23080-01R.gwa,dd.april.2008.ResponsetoThird-PartyReview
File No. 23080-01R liAnTierican Geotechnical, Inc.
April 29, 2008
APPENDIX A
Third Party Review
Apr-18-2008 14:38 Froni-O'DAY CONSULTANTS 7609318680 T-986 P.002/003 F-777
BUREAU
VERITAS
April 9, 2008 Contract No.: 148589
Mr. Steve Bobbett
City cf Carlsbad-Publio Works
1635 Faraday Avenue
Carlsbad, CA 92008
Subject: Third-Party Review of Construction Revision
Landslide Stabilization
Banich, Powers, Calso Landslide
2416 Sacada Circle
Carisbad, California
Dear Mr. Bobbett:
introduction
As requested, Bureau Veritas North America, Inc. has perfomned a third-party
geotechnical review of the constmction revision for the subject project. The
purpose of our review was to provide an opinion on whether the geotechnical
aspects of the construction revision have been identified and appropriately
addressed In the project geotechnical documents. This letter presents the
results of our third-party review. Our review is based on geotechnical data
presented in the project geotechnical documents and our professional
judgment. We have not performed a subsurface investigation, laboratory
testing or Independent geotechnical analysis for the project. The following
project documents were provided for our review:
1. "Interim Repair Recommendations, Landslide Stabilization, Banich,
Powers, Calso Landslides, 2416 Sacada Circle, Carisbad, Califomia,"
prepared by American Geotechnical, Inc., File No. 23080-02, dated
February 19,2008.
2. "Landslide Stabilization Recommendations, Banich Powers, Calso
Landslides, 2416 Sacada Circle, Carisbad, Califomia 92009," prepared
by American Geotechnical, Inc., File No. 23080.02, dated March 27
2007.
3. "Project Plans for Banich, Powers, Calso Landslide Stabilization," Sheets
1 to 6, prepared by American Geotechnical, inc., dated March 27,2007.
Testing Engineers San Diego
A Bvrmw Veritas Company ^^^^.^ gjg 7,5 jg^Q
7R95 Convoy Court. Suite 18 Pa^,. 7,3 55, Q
^tin Oi^ec CA 92111 w>^w.uS.burvauyeriu«.com
Apr-18-2008 14:39 Froni-O'DAY CONSULTANTS 7609318680
CHy of Cartebad
Banich, Powers, Calso Landslide
T-986 P.003/003 F-777
Contract No.: 148569
Results of Review
Based on our geotechnical engineering review it is our opinion that the
following comment should be addressed by the project geotechnical engineer
of record:
1. In reviewing Interim Repair Recommendations (see reference no. 1),
American Geotechnical, Inc. states in the third paragraph of Issue No 2 that
"In terms of gross stability, the factor of safety Is unchanged for the upper
part of the slope due to the support provided by the three tieback walls and
additional soil reinforcement." Since the slope ratio will change from 1 51
(horizontal to vertical) to 1.2:1, It Is unlikely that the factor of safety for the
gross slope stability will remain unchanged. In any case, the geotechnical
engineer of record should provide global slope stability analyses showing
that the factor of safety is greater than 1.5 and 1.1 for the static and seismic
conditions, respectively.
The opportunity to be of service on this project is appreciated. If you have any
questions regarding our review, please contact our office.
Respectfully submitted,
Testing Engineers - San Diego, Inc.
A Bureau Veritas Company
Nick Tracy, EIT
Staff Engineer
^an Olin, PE, GE
Principal Geotechnica
lene CiKttenborder, CEG
Senior Engineering Geologist
NT/GCA/0:cs
Distribution: (4) Addressee
File No. 23080-01R
April 29, 2008
liAmerican Geotechnical, Inc.
APPENDIX 8
Gross Slope Stability Analyses
150 —
120 —
90 -
Description: Banich
Comments: Slide Removal with Buttress and groundwater contr
File Name: Banich - 4.slp
Last Saved Date: 9/21/06
Last Saved Time: 12:40:18 PM
Analysis Method: Bishop
Direction of Slip Movement: Right to LeJ
Slip Surface Option: Grid and Radiuj
P.W.P. Option: Piezometric Line^^u
Soil; 1
Description: Fill
Soil Model: Mohr-CoulomJ
Unit Weight: 125
Cohesion; 250 Gescnption. Sandst^e
Phi- 33 ^^'^^i Mchr-Coulomb
Unit Weight: 125
Cohesion: 1000
Phf- 40
- 150
i = 60
(D
r
Soil: 3
Description: Buttress
Soil Model: Mohr-Coulomb
Unit Weight; 125
Cohesion: 100
Phi: 33
30 'rr-
Horizontal Scale (feet)