Loading...
HomeMy WebLinkAboutCT 03-06; BLACK RAIL 16; PAD CERTIFICATIONS; 2007-08-21EXCEL ENGINEERING LEVIN & DEN TINO INC. D.B.A. EXCEL ENGINEERING ESCONDIDO 440 State Place • Escondido, CA 92029 (760) 745-8118 • Fax 745-8134 In August 21, 2007 RE: Certification of Pad Grade for Lots 1 and 2 of the City of Carlsbad Drawing No. 434-9A, Project No. CT 03-06, Rough Grading Plans for Black Rail-16 To whom it my concern, Excel Engineering performed a field survey on May 3, 2007 to confirm finish pad grades for the referenced site. A minimum of 11 shots was taken across the finished pad and the grades are as follows: Pads Average Elevation Design Elevation 1 375.55 375.50 2 375.98 376.00 The maximum deviation from design to finish pad for said pads was found 0.1'. The pads are in substantial conformance with the approved grading plan. If you have any further questions or need any additional information do not hesitate to call. Sincerely, Mathew J. Muckerman, PLS (t'thwJ. !c. 7D3 1122/08 2:01 PM Q:\07\07008t00CSpadcerts lots 1-2.oc EXCEL ENGINEERIN,G LEVIN & DENTINO INC. D.B.A. EXCEL ENGINEERING ESCONDIDO 440 State Place • Escondido, CA 92029 (760) 745-8118 • Fax 745-8134 11 August 21, 2007 RE: Certification of Pad Grade for Lots 3, 4, 5, 6, 7 and 8 of the City of Carlsbad Drawing No. 434-9A, Project No. CT 03-06, Rough Grading Plans for Black Rail-16 To whom it my concern, Excel Engineering performed a field survey on April 26, 2007 to confirm finish pad grades for the referenced site. A minimum of 10 shots was taken across the finished pad and the grades are as follows: Pads Average Elevation Design Elevation 3 375.50 375.50 4 375.01 375.00 5 369.50 369.50 6 366.48 366.50 7 360.49 360.50 8 357.90 358.00 The maximum deviation from design to finish pad for said pads was found 0.1'. The pads are in substantial conformance with the approved grading plan. If you have any further questions or need any additional information do not hesitate to call. Sincerely, Mathew J. Muckerman, PLS - ( N 1/22108 2:01 PM Q:\07\07008\1DOCSpadcerts lots 3-8.doc EXCEL ENGINEERING LEVIN & DEN TINO INC. D.B.A. EXCEL ENGINEERING ESCONDIDO 440 State Place • Escondido, CA 92029 (760) 745-8118 • Fax 745-8134 4; August 21, 2007 RE: Certification of Pad Grade for Lots 9, 10, 11, 12, 13, 14, 15 and 16 of the City of Carlsbad Drawing No. 434-9A, Project No. CT 03-06, Rough Grading Plans for Black Rail-16 To whom it my concern, Excel Engineering performed a field survey on April 19, 2007 to confirm finish pad grades for the referenced site. A minimum of 10 shots was taken across the finished pad and the grades are as follows: Pads Average Elevation Design Elevation 9 357.02 357.00 10 359.00 359.00 11 363.96 364.00 12 368.54 368.50 13 373.96 374.00 14 376.00 376.00 15 376.00 376.00 16 371.96 372.00 The maximum deviation from design to finish pad for said pads was found 0.1'. The pads are in substantial conformance with the approved grading plan. If you have any further questions or need any additional information do not hesitate to call. Sincerely, Mathew J. Muckerman, PLS 1/22/08 2:01 PM Q:\07\07008\DOCS\padcerts lots 9-16.doc