HomeMy WebLinkAboutCT 04-08; LA COSTA VALLEY TOWNHOMES; WATER LAB REPORTS;Cfo4---O8
LABORATORY REPORT
Telephone (619) 425-1993 Fax 425-7917 Established 1928
CLARKSON LABORATORY AND S.UPPLY INC.
350Trousdale Dr. Chula Vista, Ca. 91910 www.clarksonlab.com
ANALYTICAL AND CONSULTING CHEMISTS
Date: July 20, .2.012
Purchase Order Number: JOB# 1202
Sales Order Number: 11644•
Account Number: WESC
To:
* ----------------------------------------------------
West Coast Underground
7929 Silverton Avenue, Ste 613
San Diego, Ca 92126
Attention: Emily Banner
Lakoratory Number: B4194 Customers Phone: 858-689-7900
Fax: 858-689-7913
Sample Designation:
* ----------------------------------- ----------------*
Seven water samples received on 07/18/12 at 2:55pm,
taken on 07/18/12 from 1:00 to 2:00pm by Clarkson Laboratory
taken from La Costa Village Town Homes marked as follows:
ANALYSIS: Per EPA Drinking Water, National Primary Drinking Water
Regulations. . . .
Test Method Colilert (MMO-MUG)
Plate Count per APHA 18th Ed. 1992 Test Method No..9215B
Your Plate Method @ 35 C/48hr Plate Count Agar
Fecal Plate
Total Coliform Count
Coliform. (E I) CFU/ml
#1 St 0+29 1" W/S . .' ABSENT
--------------------------------------------
ABSENT . 350
#2 St 11+23 1" W/S . . ABSENT ABSENT '75
#3 St 9+32 1" W/S ABSENT ABSENT 10
#4 St 8+38 1" W/S' ABSENT ABSENT 25
C152St 1+24 1" W/S cRESENTJ ABSENT C4201
#6 St 2+25 End Cap . ABSENT ABSENT 18
#7 St 6+88 End Cap
.
ABSENT ABSENT 72
The results indicate that the water sample #5 is not
microbiologically safe for drinking.
Note: CFU = Colony Forming Units.
Is the symbol for, less than.
Rosa M. Bernal
RNB/mlv
LABORATORY REPORT
Telephone (619) 425-1993 Fax 425-7917 Established 1928
CLARKSON LABORATORY AND SUPPLY INC.
350 Trousdale Dr. Chula Vista, Ca. 91910 www.clarksonlab.com
ANALYTICAL AND CONSULTING CHEMISTS
Date: July 27, 2012
Purchase Order Number: JOB# 1202
Sales Order Number: 11728
Account Number: WESC
To:
*------------------------------------ -------------*
West Coast Underground
7929 Silverton Avenue, Ste 613
San Diego, Ca 92126
Attention: Emily Banner
Laboratory Number: B4218 Customers Phone: 858-689-7900
Fax: 858-689-7913
Sample Designation:
*-------------------------------------------------*
Seven water samples received on 07/25/12 at4:00pm,
taken on 07/25/12 from 2:15pm to 3:0015m by Clarkson
Laboratory, from La Costa Village Town Homes
marked as follows:
ANALYSIS: Per EPA Drinking Water, National Primary Drinking Water
Regulations.
Test Method Colilert (MMO-MUG)
Plate Count per APHA 18th Ed. 1992 Test Method No.9215B
Pour Plate Method @ 35 C/48hr Plate Count Agar
Fecal Plate
Total Coliform Count
Coliform (E-Coli) CFU/ml
#1 St 0+29 1" W/S ABSENT
--------------------------------------------
ABSENT 100
#2 St 11+23 1" W/S ABSENT ABSENT 310
#3 St 9+32 111. W/S ABSENT ABSENT 135
#4 St 8+38 1" W/S ABSENT ABSENT 100
#5 St 1+24 1" W/S • •• ABSENT ABSENT 110
#6 St 2+25 End Cap ABSENT ABSENT 230
#7 St 6+88 End Cap ABSENT ABSENT 140
The results indicate that these water samples are
microbiologiäally
•
safe for drinking.
Note: CFU= Colony Forming Units.
< Is the symbol for less than.
Laura -Torres
LT/arr •
LABORA'TORY "RE PORT
Telephone (619) 425-1993 Fax 425-7917 Established 1928
CLARKSON LABORATORY AND SUPPLY INC.
350 Trousdale Dr. Chula Vista, Ca. 91910 www.clarksonlab.com
ANALYTICAL AND CONSULTING CHEMISTS
Date: July 28, 2012
Purchase Order Number: JOB# 1202
Sales Order Number: 11728
Account Number: WESC
To:
* -------------------------------------------------
West Coast Underground
7929 Silverton Avenue, Ste 613
San Diego, Ca 92126
Attention: Emily Banner
Laboratory Number: B4222 Customers Phone: 858-689-7900
Fax: 858-689-7913
Sample Designation:
*-------------------------------------------------*
Seven water samples received on 07/26/12 at 3:50pm,
taken on 07/26/12 from 2:10pm to 2:50pm by Clarkson Laboratory
taken from La Costa Village Town Homes marked as follows:
ANALYSIS: Per EPA Drinking Water, National Primary Drinking Water
Regulations.
Test Method Colilert (MMO-MUG)
Plate Count per APHA 18th Ed. 1992 Test Method No.9215B
Pour Plate Method @ 35 C/48hr Plate Count Agar
Fecal Plate
Total Coliform Count
Coliform (E-Coli) CFU/ml
#1 St 0+29 1" W/S ABSENT
--------------------------------------------
ABSENT 490
#2 St 11+23 1" W/S ABSENT ABSENT 710
#3 St 9+32 1" W/S ABSENT ABSENT 700
#4 St 8+38 1" W/S ABSENT ABSENT 710
#5 St 1+24 1" W/S ABSENT ABSENT
#6 St 2+25 End Cap ABSENT ABSENT 560
#7 St 6+88 End Cap ABSENT ABSENT 760
The results indicate that water samples 2 through 7 are not
microbiologically safe for drinking.
Note: CFU = Colony Forming Units.
< Is the symbol for less than.
Mr. Leslie S. Shannon
LSS/sd
LABORATORY REPORT
Telephone (619) 425-1993 Fax 425-7917 Established 1928
CLARKSON LABORATORY, AND SUPPLY INC.
350 Trousdale Dr. Chula Vista, Ca. 91910 www.c1arksonlab,om
ANALYTICAL AND CONSULTING CREMISjTS
Date: August 9, 2012
Purchase 02der Number: 1202
Sales Order Number: 11879
Account Number: WESC
To:
* ----------------------------------------------
West Coast Underground
7929 Silverton Avenue, Ste 613
San Diego, Ca 92126
Attention: Emily Banner
Laboratory Number: 84267 Customers Phone: 958-699-7900
Fax: 958-699-7913
Sample Designation:
------------------- ------------------------------* Seven water samples received on 08/08/12 at 4:00pm,
taken on 08/08/12 from 1:00pm to 2:20pm by Clarkson' Laboratory,: from La Costa Village Town Homes marked as follows:
ANALYSIS: Per EPA Drinking Water, National Primary Drinking Water!. Regulations.
Test Method Colilert (MMO-MUc)
Plate Count per APHA 18th Ed. 1992 Test Method No.9215B
Pour Plate Method @ 35 C/48hr Plate Count' Agar
Fecal Plate
Total Calif arm Count
Coliform (E-Coli) CFU/In].
#1 St 0+29 1" W/S ' ' •' ABSENT ABSENT *
#2 St 11+23 '1" W/S ABSENT ABSENT ' *
#3 St ' 9+32 1" W/S ABSENT ' ABSENT , *
#4 St 8+38 1" W/S ' ABSENT 'ABSENT *
#5 St 1+24 It, W/S ' PRESENT ABSENT " *
#6 St 2+25 End Cap ABSENT ABSENT *
- #7 St 6+88 End 'Cap PRESENT 'ABSENT ' *
The results indicate that the water samples #5 and '#7 are not microbiologically safe for drinking.
Note: * Results are pending - CFU = Colony Forming Units. < Is the symbol for less than.
Laura Torres
LT/arr
Z0/Z0 _ 39Vd NOS)l10 L16L906I9 60:9t IO/60/80
08/10/2012 15:17 6194257917 CLARKSON PAGE 02/2
LABORATORY REPORT
Telephone (619) 425-1993 Fax 425-7917 Established 1928
CLARKSON LABORATORY AND SUPPLY INC.
350 Trousdale Dr. Chula Vista, Ca. 91910 w.clarksonlab.com
ANALYTICAL AND CONSULTING CHEMISTS
Date: August 10, 2012
Purchase Order Number: 1202
Sales Order Number: 11879
Account Number: WESC
To:
* -------------------------------------------------*
West Coast Underground
7929 Silverton Avenue, Ste 613
San Diego, Ca 92126
Attention: Emily Banner
Laboratory Number: 84267 Customers Phone: 858-689-7900
Fax: 858-689-7913
Sample Designation:
* -------------------------------- ------------------*
Seven water samples received on 08/08/12 at 4:00pm,
taken on 08/08/12 from 1:00pm to 2:20pm by Clarkson Laboratory
taken from La Costa Village Town Homes marked as follows:
ANALYSIS: Per EPA Drinking Water, National Primary Drinking Water.
Regulations.
Test Method Colilert (1'2d0-MUG)
Plate Count per APRA 18th.Ed. 1992 Test Method No.92153
Pour Plate Method @ 35 C/48br Plate Count Agar
Fecal Plate
Total Coliform Count
Coliform (E-Coli) CFTJ/mi
#1 St 0+29 1" w/S ABSENT ABSENT 1000
#2 St 11+23 1" W/S ABSENT ABSENT >5700
#3 St. 9+32 1" W/S ABSENT ABSENT 310
#4 St 8+38 1" W/S ABSENT ABSENT 690
#5 St 1+24 1" W/S PRESENT ABSENT 780
#6 St 2+25 End Cap ABSENT ABSENT >5700
#7 St 6+88 End Cap PRESENT ABSENT 550
The results indicate that water sample #3 is
microbiologically safe for drinking.
Note: CFU = Colony Forming Units.
< Is the symbol for less than.
Rosa M. Bernal
PMB/mlv
LABORATORY REPORT
Telephone (619) 425-1993 Fax 425-7917 Established 1928
CLARKSON LABORATORY AN °DSUPPLY INC.
350 Trousdale Dr. Chula Vista, Ca. 91910 www.clarksonlab.com
ANALYTICAL AND CONSULTING CHEMISTS
Date: August 15, 2012
Purchase Order Number: 1202
Sales Order Number: 11950
Account Number: WESC
To:
* --------------------------------------------------
West Coast Underground
7929 Silverton Avenue, Ste 613
San Diego, Ca 92126
Attention: Emily Banner
Laboratory Number:.B4281 Customers Phone: 858-689-7900
Fax: 858-689-7913
Sample Designation:
* --------------------------------- ------------------*
Eight water samples received on 08/13/12 at 4:35pm,
taken on 08/13/12 from 2:25pm to 3:30pm by Clarkson
Laboratory, from La Costa Village Town Homes
marked as follows:
ANALYSIS: Per EPA Drinking Water, National Primary Drinking Water.
Regulations.
Test Method Colilert (MMO-MUG)
Plate Count per APHA 18th Ed. 1992 Test Method No.9215B
Pour Plate Method @ 35 C/48hr Plate Count Agar
Fecal Plate
Total Coliform Count
Coliform (E-Coli) CFU/rn].
#1 St 0+29 1" W/S ABSENT
--------------------------------------------
ABSENT 4
#2 --St 11+23 1" W/S . ABSENT ABSENT . 4
#3 St 9+32 1" W/S ABSENT ABSENT .40
#4 St. 8+38 1" W/S ABSENT ABSENT 160
#5 St 1+24 1" W/S . . ABSENT ABSENT 150
#6 St 2+25 End Cap ABSENT ABSENT 19
#7 St 6+88 End Cap . ABSENT ABSENT 57
#8 Source . ABSENT ABSENT . 1
The results indicate that these water samples are
microbiologically safe for drinking.
Note: CFU = Colony, Forming Units.
< Is the symbol for less than.
010
Laura Torres
LT/arr .
LABORATORY REPORT
Telephone (619) 425-1993 Fax 425-7917 Established 1928
CLARKSON LABORATORY AND SUPPLY INC.
350 Trousdale Dr. Chula Vista, Ca. 91910 www.clarksonlab.com
ANALYTICAL AND CONSULTING CHEMIST.S
Date: August 16, 2012
Purchase Order Number: 1202
Sales Order Number: 11950
Account Number: WESC
To:
* -------------------------------------------------
West Coast Underground
7929 Silverton Avenue, Ste 613
San Diego, Ca 92126
Attention: Emily Banner
Laboratory Number: B4293 Customers Phone: 858-689-7900
Fax: 858-689-7913
Sample Designation:
* ------------------------------ -------------------*
Eight.water samples received on 08/14/12 at 4:35pm,
taken on 08/14/12 from 2:30pm to 3:30pm by Clarkson
Laboratory, from La Costa Village Town Homes
marked as follows:
ANALYSIS: Per EPA Drinking Water, National Primary Drinking Water
Regulations.
Test Method Colilert (MMO-MUG)
Plate Count per APHA18th Ed. 1992 Test Method No.9215B
Pour Plate Method @ 35 C/48hr Plate Count Agar
#1 St 0+29 1" W/S
#2 St 11+23 1" W/S
#3 St 9+32 1" W/S
#4 St 8+38 1" W/S
#5 St 1+24 W/S
#6 St 2+25 End Cap
#7 St 6+88 End Cap
#8 Source
Feca]. Plate
Total Coliform Count
Coliform (E-Coli) CFU/ml
ABSENT
---------------------------------------------
ABSENT 15
ABSENT ABSENT 11
ABSENT ABSENT .64
ABSENT ABSENT 14
ABSENT ABSENT 45
ABSENT ABSENT 130
ABSENT . ABSENT 66
ABSENT ABSENT . 1
The results indicate that these water samples are
microbiologically safe for drinking.
Note: CFU = Colony Forming Units.
< Is the symbol for less than.
Laura Torres
LT/arr
LABORATORY REPORT
Telephone (619) 425-1993 Fax 425-7917 Established 1928
CLARK.SON LABORATORY AND SUPPLY INC.
350 Trouda1e Dr. Chula Vista, Ca. 91910 www.c1arksonlsb.com
ANALYTICAL AND CONSULTING CHEMISTS
Date: August9,. 2012
Purchase Ordör Number: 1202
Sales Order'umber: 11879
Account Number: WESC
To:
* -----------..- -------------------------------------*
West Coast tJnderground
7929 Silverton Avenue, Ste 613
San Diego, CI 92126
Attention: .i1y Banner
Laboratory Niuuber: 34263 Customers Phone: 858-689-7900
Fax; 858-689-7913
Sample Desigflation:
* ----------- --------------------------------------*
Seven water;samples received on 08/07/12 at 2:10pm,
taken on 08/07/12 from 1:00pm to 1:30pm by Clarkson, Laboratory
from La Costa Village Town Homes marked as follows:
ANALYSIS: Pe,r EPA Drinking Water,, National Primary Drinking Water
Rg4ations.
Test Method Colilert (HMO-MUG)
Plate Count per APHA 18th Ed. 1992 Test Method No.9215B
Pour Plate Method @ 35 C/48hr Plate Count Agar
J.
. Fecal Plate
Total Coliform Count
Coliform (E-Col1) CFU/ml
#1 St 0+2.9. 3." W/S . ABSENT
--------------------------------------------
ABSENT 5
#2 St 11+23..1" W/S ABSENT ABSENT 100
#3 St 9+32' 1" W/S ABSENT ABSENT . 16
#4 St 8+383." W/S ABSENT ABSENT 65
#5 St 1+24'1" W/S S ABSENT ABSENT . 48
#6 St 2+25Eiid Cap . ABSENT ABSENT 130
#7 St 6+88End Cap ABSENT ABSENT 91
The results indicate that these water samples are
microbiolcigcally safe for drinking.
Note: Crdr = Colony Forming Units.
Is the symbol for less than.
Laura Torrs