HomeMy WebLinkAboutCT 04-16; LA COSTA GREENS NGBHD 1.06; WATER SYSTEM ANALYSIS; 2004-07-29I I I I t I I WATER SYSTEM ANALYSIS I FOR LA COSTA GREENS NEIGHBORHOODS 1.06 AND 1.07 I July 29, 2004 I I I I I r I Dexter Wilson Engineering, Inc. (,:' 703 Palomar Airport Road E::..-" Suite 300 Itt: i I Carlsbad, CA 92009 I; ; (760) 438-4422 ' 'l .~J;I I l' '~ ~ t· s I t g ""'. 12: .... ·:iiI ~1 I Job Number: 681-024 ~~UI ~ 01 6Lf-/(p "'i ~ I ~ ..e:. :J... I I I I I I I I I I I' I I I I I I I I DEXTER WILSON ENGINEERING, INC. July 29, 2004 Morrow Development 1903 Wright'Place, Suite 180 Carlsbad, CA 92008 Attention: Tim O'Grady, Vice President DEXTER S. WILSON, P.E~ ANDREW M. OVEN, P.E. STEPHEN M. NIELSEN, P.E. MICHAEL J. FILECCIA, P.E. DIANE H. SHAUGHNESSY, P.E. 681-024 Subject: Water System Analysis for La Costa Greens Neighborhoods 1. 06 and 1. 07 Introduction This letter-report provides a water system analysis for Neighborhoods 1.06 and 1.07 of the La Costa Greens project. This report determines the requited water line sizes to meet domestic and fire flow requirements for the project and identifies connections to the existing water system that will occur in the vicinity of the project. The portion of La Costa Greens covered by this study is located north of Poinsettia Lane, east of Alicante Road, and south ofthe Bressi Ranch project. The neighborhoods analyzed in this study are identified on Figure 1. Neighborhood's 1.06'and 1.07 of the La Costa Greens project are within the 375 Zone of the Carlsbad Municipal Water District (CMWD) for service. The project will obtain water service by connecting to a 16-inch water line in Poinsettia Lane. The water system improvements internal to the project will be completed concurrent with required street improvements for the project. The portion of La Costa Greens analyzed herein proposes single family residential development, and an elementary school site. Figure 1 provides the proposed 703 PALOMAR AIRPORT ROAD, SUITE 300 • CARLSBAD, CA 92009 • (760) 438·4422 • FAX (760) 438.0173 I I I I I I I I I I I I I I I I I I I Tim O'Grady July 29, 2004 Page 2 development layout for the project. Water System Design Criteria The basic design criteria utilized in sizing the water distribution system piping includes a minimum residual pressure of 40 psi under peak hour flow conditions, and a residual pressure of at least 20 psi under maximum day demand plus fire flow conditions. The peaking factors used in analyzing various demand scenarios are 1.65 for average day to maximum day demands, and 2.9 for average day to peak hour demands. A computer analysis (KYPIPE Program, University of Kentucky) was used to determine residual pressures throughout the distribution system model. This computer program utilizes the Hazen -Williams equation for determining headloss with a "C" value of 120 used for all pipes. Fire Flows The fire flow requirement from the March 2003 CMWD Water Master Plan Update is 1,500 gpm for single family residential development. A fire flow of 4, 000 gpm was used for the elementary school site. The fire flow demand for the school site was split evenly between two hydrants. Proiected Water Demand . The projected water demand for the La Costa Greens project was estimated by using water duty factors from the March 2003 CMWD Water Master Plan Update. Table 1 summarizes the development, water duty factors, and projected water demand for the project. The projected average daily demand for the project is 78,210 gpd (54 gpm). I I I I I I I I I I I I I I I I I I I Tim O'Grady July 29,2004 Page 3 This results in projected maximum day and peak hour water demands of 89 gpm and 157 gpm, respectively. TABLE 1 LA COSTA GREENS PROJECTED WATER DEMANDS 1.06 92 units 386 gpdJunit 35,510 1.07 71 units 386 gpdJunit 27,410 School 10 acres 1,529 gpdJac 15,290 Existing Water System Facilities Neighborhoods 1.06 and 1.07 of the La Costa Greens project are located within the 375 Water Service Zone of the CMWD. This area of the District's system will be supplied by two pressure reducing stations. The 700/375 Zone pressure reducing station was recently constructed along Poinsettia Lane, just east of the project. This station supplies the 16-inch 375 Zone line in Poinsettia Lane. A 510/375 Zone pressure reducing station is to be constructed within Neighborhood CT 02-23 of the La Costa Greens project. This station is located south of Poinsettia Lane and will supply an 8- inch line in Alicante Road. Water System Analysis Appendix A contains the computer analyses performed for the project. Exhibit "A" presents the node and pipe diagram for the onsite computer model and shows the recommended water system sizes for the piping within the project. The modeling performed for the project includes maximum day demand plus fire flow scenarios; as' I I I I I I I I I I I I I I I -I I I I Tim O'Grady July 29, 2004 Page 4 well as average day demand and peak hour demand scenarios Proposed Water System Figure 1 provides the proposed potable water system for Neighborhoods 1.06 and 1.07 of the La Costa Greens project. The project will be supplied by connecting to the proposed 16-inch water line in Poinsettia Lane and constructing onsite 8-inch water lines. The computer output in Appendix A verifies that construction of the improvements on Figure 1 will provide adequate domestic and fire protection service to La Costa Greens Neighborhoods 1.06 and 1.07. Table 2 summarizes the expected lot elevation and static pressure ranges for the project. TABLE 2 WATERSER~CEZONESU~Y LEGEND - - -EXISTING 375 ZONE WATER UNE --PROPOSED 375 ZONE WATER UNE NOTE: ALL PIPES ARE RECOMMENDED AS 8-UNLESS OTHERWISE SHOWN BRESSI RANCH ::::-=r: SCAL£: I" = 400' FIGURE 1 NEIGHBORHOODS 1.06 AND 1.07 PROPOSED WATER FACILITIES ", ~ I. I I I I I I I I I I I I I I I I I I Tim O'Grady July 29,2004 Page 6 Conclusions and Recommendations The following is a summary of our conclusions and recommendations based on our study: 1. The recommended potable water system configuration and sizes for pipelines to serve La Costa Greens Neighborhoods 1.06 and 1.07 are shown on Figure 1. 2. Water service to the project will be provided by the CMWD 375 Zone Water System. Two connections to the 16-inch water line in Poinsettia Lane, and two connections to the existing 8-inch line in Aliconte Road are recommended. 3. Individual pressure regulating valves should be installed on all lots that are expected to have water service pressures of greater than 80 psi. 4. As summarized in Table 2, some of the upper lots within the project will receive marginally low static pressures ofless than 60 psi. The computer modeling verifies that adequate fire protection service can be provided to all lots on the project. -----------~~~~~~~~ I I I I I I I I I I I I I I I I I I I Tim O'Grady July 29, 2004 Page 7 Thank you for the opportunity to assist you with the water system planning for this project. If you have any questions regarding the contents of this report, please do not hesitate to calL We are available to discuss this report with you at your convenience. Dexter Wilson Engineering, Inc. Stephen M. Nielsen SMN:jaa Attachments I I I I APPENDIX A I COMPUTER OUTPUT I I I I I I I I I I I I I I I I I I I I I I. I I I I I I I I I I I . The following conditions were modeled: 1. Average Day Demands 2. Maximum Day Demands plus 4,000 gpm Fire Flow split between Nodes 10 and 24 3. Maximum Day Demands plus 1,500 gpm Fire Flow at Node 54 4. Maximum Day Demands plus 1,500 gpm Fire Flow at Node 46 . 5. Maximum Day Demands plus 1,500 gpm Fire Flow at Node 30 6. Peak Hour Demands I I I FLOWRATE IS EXPRESSED IN GPM AND PRESSURE IN PSIG I A SUMMARY OF THE ORIGINAL DATA FOLLOWS I I PIPE NO. NODE NOS. LENGTH DIAMETER ROUGHNESS MINOR LOSS K FIXED GRADE (FEET) (INCHES) 1 0 2 200.0 16.0 120.0 .00 375.00 I 3 2 4 1200.0 16.0 120.0 .00 5 4 6 475.0 16.0 120.0 .00 7 6 8 730.0 16.0 120.0 .00 9 2 10 200.0 8.0 120.0 .00 I 11 10 12 225.0 8.0 120.0 .00 13 12 14 450.0 8.0 120.0 .00 15 14 16 450.0 8.0 120.0 .00 I 17 16 32 200.0 8.0 120.0 .00 19 18 16 400.0 8.0 120.0 .00 21 20 18 425.0 8.0 120.0 .00 23 22 20 325.0 8.0 120.0 .00 I 25 24 22 190.0 8.0 120.0 .00 27 4 24 250.0 8.0 120.0 .00 29 22 26 290.0 8.0 120.0 .00 31 26 28 350.0 8.0 120.0 .00 I 33 32 30 525.0 8.0 120.0 .00 35 32 34 400.0 8.0 120.0 .00 37 34 36 525.0 8.0 120.0 .00 I 39 36 40 640.0 8.0 120.0 .00 41 40 38 400.0 8.0 120.0 .00 43 42 40 175.0 8.0 120.0 .00 45 42 44 300.0 8.0 120.0 .00 I 47 44 46 150.0 8.0 120.0 .00 49 48 42 475.0 8.0 120.0 .00 51 50 48 350.0 8.0 120.0 .00 I 53 58 50 215.0 8.0 120.0 .00 55 52 50 380.0 8.0 120.0 .00 57 54 52 450.0 8.0 120.0 .00 59 56 54 400.0 8.0 120.0 .00 I 61 58 56 950.0 8.0 120.0 .00 63 8 58 2400.0 8.0 120.0 .00 I JUNCTION NUMBER DEMAND ELEVATION CONNECTING PIPES 2 .00 134.70 1 3 9 4 .00 122.70 3 5 27 I 6 .00 115.00 5 7 8 .00 117.00 7 63 10 1.00 144.00 9 11 12 2.00 159.50 11 13 I 14 3.00 180.10 13 15 I I I I I I I I 'I I I I I I I I I I I I 16 2.00 188.90 15 -17 19 18 2.00 169.80 19 21 20 2.00 150.00 21 23 22 2.00 130.30 23 25 29 24 .00 127.20 25 27 26 2.00 132.20 29 31 28 2.00 136.90 31 30 4.00 194.50 33 32 2.00 188.90 17 33 35 34 2.00 217.00 35 37 36 3.00 233.80 37 39 38 3.00 248.80 41 40 3.00 245.10 39 41 43 42 3.00 244.40 43 45 49 44 2.00 251.50 45 47 46 2.00 260.00 47 48 3.00 238.20 49 51 50 3.00 215.90 51 53 55 52 3.00 240.90 55 57 54 3.00 270.70 57 59 56 .00 248.00 59 61 58 .00 200.20 53 61 63 OUTPUT SELECTION: ALL RESULTS ARE OUTPUT EACH PERIOD 3 VALUES ARE OUTPUT FOR MAXIMUM AND MINIMUM PRESSURES THIS SYSTEM HAS 32 PIPES WITH 29 JUNCTIONS , 3 LOOPS AND 1 FGNS THE RESULTS ARE OBTAINED AFTER 9 TRIALS WITH AN ACCURACY .00013 WATER ANALYSIS 681-024 LA COSTA GREENS NEIGHBORHOODS 1.06 AND 1.07 AVERAGE DAILY DEMAND PIPE NO. NODE NOS. FLOWRATE HEAD LOSS PUMP HEAD MINOR LOSS VELOCITY HL/1000 1 0 2 54.00 .00 .00 .00 .09 .00 3 2 4 34.56 .00 .00 .00 .06 .00 5 4 6 15.37 .00 .00 .00, .02 .00 7 6 8 15.37 .00 .00 .00 .02 .00 9 2 10 19.44 .00 .00 .00 .12 .01 11 10 12 18.44 .00 .00 .00 .12 .01 13 12 14 16.44 .00 .00 .00 .10 .01 15 14 16 13.44 .00 .00 .00 .09 .01 17 16 32 20.63 .00 .00 .00 .13 .02 19 18 16 9.20 .00 .00 .00 .06 .00 21 20 18 11.20 .00 .00 .00 .07 .01 23 22 20 13.20 .00 .00 .00 .08 .01 25 24 22 19.20 .00 .00 .00 .12 .01 27 4 24 19.20 .00 .00 .00 .12 .01 29 22 26 4.00 .00 .00 .00 .03 .00 31 26 28 2.00 .00 .00 .00 .01 .00 I I I I I I I I I I I I I I I I I I I 44 2.00 374.97 251. 50 53.50 THE NET SYSTEM DEMAND 54.00 SUMMARY OF INFLOWS(+) AND OUTFLOWS(-) FROM FIXED GRADE NODES PIPE NUMBER 1 FLOWRATE 54.00 THE NET ~LOW INTO THE SYSTEM FROM FIXED GRADE NODES = THE NET FLOW OUT OF THE SYSTEM INTO FIXED GRADE NODES 54.00 .00 A SUMMARY OF CONDITIONS SPECIFIED FOR THE NEXT SIMULATION FOLLOWS THE DEMANDS ARE CHANGED FROM ORIGINAL VALUES BY A FACTOR = 1.65 THE FOLLOWING SPECIFIC DEMAND CHANGES ARE MADE : JUNCTION NUMBER DEMAND 10 2002.00 24 2000.00 THE RESULTS ARE OBTAINED AFTER 5 TRIALS WITH AN ACCURACY .00028 MAXIMUM DAY DEMANDS PLUS 4000 GPM FIRE SPLIT BETWEEN NODES 10 AND 24 PIPE NO. NODE NOS. FLOWRATE HEAD LOSS PUMP HEAD MINOR LOSS VELOCITY 1 0 2 4089.45 1. 97 .00 .00 6.53 3 2 4 2064.21 3.33 .00 .00 3.29 5 4 6 320.91 .04 .00 .00 .51 7 6 8 320.91 .06 .00 .00 .51 9 2 10 2025.24 15.66 .00 .00 12.93 11 10 12 23.24 .00 .00 .00 .15 13 12 14 19.94 .01 .00 .00 .13 15 14 16 14.99 .00 .00 .00 .10 17 16 32 -261. 51 -.35 .00 .00 -1.67 19 18 16 -273.20 -.77 .00 .00 -1. 74 21 20 18 -269.90 -.80 .00 .00 -1.72 23 22 20 -266.60 -.60 .00 .00 -1.70 25 24 22 -256.70 -.32 . 00 .00 -1. 64 . 27 4 24 1743.30 14.83 .00 .00 11.13 29 22 26 6.60 .00 .00 .00 .04 31 26 28 3.30 .00 .00 .00 .02 33 32 30 6.60 .00 .00 .00 .04 35 32 34 -271.41 -.76 .00 .00 -1. 73 37 34 36 -274.71 -1. 02 .00 .00 -1. 75 39 36 40 -279.66 -1. 28 .00 .00 -1.78 41 40 38 4.95 .00 .00 .00 .03 43 42 40 289.56 .37 .00 .00 1.85 45 42 44 6.60 .00 .00 .00 .04 HL/I000 9.84 2.77 .09 .09 78.28 .02 .02 .01 -1.77 -1. 92 -1.87 -1. 83 -1.71 59.31 .00 .00 .00 -1. 89 -1. 94 -2.00 .00 2.l3 .00 I. I' 47 44 46 3.30 .00 .00 .00 .02 .00 49 48 42 301.11 1. 09 .00 .00 1. 92 2.29' I' 51 50 48 306.06 .83 .00 .00 1. 95 2.36 53 58 50 247.42 .34 .00 .00 1.58 1.59 55 52 50 63.59 .05 .00 .00 .41 .13 57 54 52 68.54 .07 .00 .00 .44 .15 I 59 56 54 73.49 .07 .00 .00 .47 .17 61 58 56 73.49 .16 .00 .00 .47 .17 63 8 58 320.91 6.20 .00 .00 2.05 2.58 I· JUNCTION NUMBER DEMAND GRADE LINE ELEVATION PRESSURE 2 .00 373.03 134.70 103.28 I· 4 .00 369.70 122.70 107.04 6 .00 369.66 115.00 110.35 8 .00 369.60 117.00 109.46 I 10 2002.00 357.38 144.00 92.46 12 3.30 357.37 159.50 85.74 14 4.95 357.36 180.10 76.81 16 3.30 357.36 188.90 73.00 I 18 3.30 356.59 169.80 80.94 20 3.30 355.80 150.00 89.18 22 3.30 355.20 130.30 97.46 I 24 2000.00 354.88 127.20 98.66 26 3.30 355.20 132.20 96.63 28 3.30 355.20 136.90 94.60 30 6.60 357.71 194.50 70.73 I. 32 3.30 357.71 188.90 73.15 34 3.30 358.47 217.00 61.30 36 4.95 359.49 233.80 54.46 38 4.95 360.77 248.80 48.52 I 40 4.95 360.77 245.10 50.12 42 4.95 361.14 244.40 50.59 44 3.30 361.14 251. 50 47.51 I 46 3.30 361.14 260.00 43.83 48 4.95 362.23 238.20 53.75 50 4.95 363.06 215.90 63.77 52 4.95 363.11 240.90 52.96 I: 54 4.95 363.18 270.70 40.07 56 .00 363.24 248.00 49.94 58 .00 363.40 200.20 70.72 I MAXIMUM PRESSURES 6 .00 369.66 115.00 110.35 8 .00 369.60 117.00 109.46 I 4 .00 369.70 122.70 107.04 MINIMUM PRESSURES 54 4.95 363.18 270.70 40.07 I' 46 3.30 361.14 260.00 43.83 44 3.30 361.14 251. 50 47.51 I THE NET SYSTEM DEMAND 4089.45 SUMMARY OF INFLOWS(+) AND OUTFLOWS(-) FROM FIXED GRADE NODES I PIPE NUMBER FLOWRATE I. I I 1 4089.45 I THE NET FLOW INTO THE SYSTEM FROM FIXED GRADE NODES = 4089.45 THE NET FLOW OUT OF THE SYSTEM INTO FIXED GRADE NODES .00 I A SUMMARY OF CONDITIONS SPECIFIED FOR THE NEXT SIMULATION FOLLOWS I THE DEMANDS ARE CHANGED FROM ORIGINAL VALUES BY A FACTOR = 1. 65 I THE FOLLOWING SP~CIFIC DEMAND CHANGES ARE MADE : JUNCTION NUMBER DEMAND 54 1505.00 I THE RESULTS ARE OBTAINED AFTER 4 TRIALS WITH AN ACCURACY = .00005 I MAXIMUM DAY DEMAND PLUS 1500 GPM FIRE FLOW AT NODE 54 I PIPE NO. NODE NOS. FLOWRATE HEAD LOSS PUMP HEAD MINOR LOSS VELOCITY HL/I000 1 0 2 1589.15 .34 .00 .00 2·.54 1.71 I 3 2 4 1165.26 1.15 .00 .00 1. 86 .96 5 4 6 820.75 .24 .00 .00 1.31 .50 7 6 8 820.75 .37 .00 .00 1.31 .50 9 2 10 423.89 .86 .00 .00 2.71 4.32 I 11 10 12 422.24 .97 .00 .00 2.69 4.29 13 12 14 418.94 1. 90 .00 .00 2.67 4.23 15 14 16 413.99 1. 86 .00 .00 2.64 4.14 I 17 16 32 738.70 2.42 .00 .00 4.71 12.09 19 18 16 328.01 1. 08 .00 .00 2.09 2.69 21 20 18 331. 31 1.16 .00 .00 2.11 2.74 23 22 20 334.61 .91 .00 .00 2.14 2.79 I 25 24 22 344.51 .56 .00 .00 2.20 2.94 27 4 24 344.51 .74 .00 .00 2.20 2.94 29 22 26 6.60 .00 .00 .00 .04 .00 I 31 26 28 3.30 .00 .00 .00 .02 .00 33 32 30 6.60 .00 .00 .00 .04 .00 35 32 34 728.80 4.72 .00 .00 4.65 11. 79 37 34 36 725.50 6.14 .00 .00 4.63 11.69 I 39 36 40 720.55 7.39 .00 .00 4.60 11.55 41 40 38 4.95 .00 .00 .00 .03 .00 43 42 40 -710.65 -1. 97 .00 .00 -4.54 -11.25 I 45 42 44 6.60 .00 .00 .00 .04 .00 47 44 46 3.30 .00 .00 .00 .02 .00 49 48 42 -699.10 -5.19 .00 .00 -4.46 -10.92 51 50 48 -694.15 -3.77 .00 .00 -4.43 -10.78 I 53 58 50 163.10 .16 .00 .00 1.04 .74 55 52 50 -852.30 -5.99 .00 .00 -5.44 -15.76 57 54 52 -847.35 -7.02 .00 .00 -5.41 -15.59 59 56 54 657.65 3.90 .00 .00 4.20 9.75 I 61 58 56 657.65 9.26 .00 .00 4.20 9.75 I I I 63 8 58 820.75 35.27 .00 .00 5.24 14.70 I JUNCTION NUMBER DEMAND GRADE LINE ELEVATION PRESSURE 2 .00 374.66 134.70 103.98 4 .00 373.50 122.70 108.68 I 6 .00 373.27 115.00 111. 92 8 .00 372.90 117.00 110.89 10 1. 65 373.79 144.00 99.58 I 12 3.30 372.83 159.50 92.44 14 4.95 370.92 180.10 82.69 16 3.30 369.06 188.90 78.07 18 3.30 370.14 169.80 86.81 I 20 3.30 371. 30 150.00 95.90 22 3.30 372.21 130.30 104.83 24 .00 372.77 127.20 106.41 I 26 3.30 372.21 132.20 104.00 28 3.30 372.21 136.90 101. 97 30 6.60 366.64 194.50 74.60 32 3.30 366.64 188.90 77.02 I 34 3.30 361. 93 217.00 62.80 36 4.95 355.79 233.80 52.86 38 4.95 348.40 248.80 43.16 I 40 4.95 348.40 245.10 44.76 42 4.95 346.43 244.40 44.21 44 3.30 346.43 251.50 41.l4 46 3.30 346.43 260.00 37.45 I 48 4.95 341. 24 238.20 44.65 50 4.95 337.47 215.90 52.68 52 4.95 331. 48 240.90 39.25 54 1505.00 324.47 270.70 23.30 I 56 .00 328.37 248.00 34.83 58 .00 337.63 200.20 59.55 I MAXIMUM PRESSURES 6 .00 373.27 115.00 111.92 8 .00 372.90 117.00 110.89 4 .00 373.50 122.70 108.68 I MINIMUM PRESSURES 54 1505.00 324.47 270.70 23.30 I 56 .00 328.37 248.00 34.83 46 3.30 346.43 260.00 37.45 THE NET SYSTEM DEMAND 1589.15 I SUMMARY OF INFLOWS(+) AND OUTFLOWS(-) FROM FIXED GRADE NODES I PIPE NUMBER FLOWRATE 1 1589.15 THE NET FLOW INTO THE SYSTEM FROM FIXED GRADE NODES = 1589.15 I THE NET FLOW OUT OF THE SYSTEM INTO FIXED GRADE NODES .00 I I I I A SUMMARY OF CONDITIONS SPECIFIED FOR THE NEXT SIMULATION FOLLOWS I THE DEMANDS ARE CHANGED FROM ORIGINAL VALUES BY A FACTOR = 1. 65 I THE FOLLOWING SPECIFIC DEMAND CHANGES ARE MADE : JUNCTION NUMBER DEMAND 46 1503.30 I THE RESULTS ARE OBTAINED AFTER 5 TRIALS WITH AN ACCURACY .00027 I MAXIMUM DAILY DEMAND AND 1500 GPM FIRE FLOW AT NODE 46 I PIPE NO. NODE NOS. FLOWRATE HEAD LOSS PUMP HEAD MINOR LOSS VELOCITY HL/1000 1 0 2 1589.10 .34 .00 .00 2.54 1. 71- 3 2 4 1104.90 1.05 .00 .00 1. 76 .87 I 5 4 6 696.63 .18 .00 .00 1.11 .37 7 6 8 696.63 .27 .00 .00 1.11 .37 9 2 10 484.20 1.11 .00 .00 3.09 5.53 I 11 10 12 482.55 1.24 .00 .00 3.08 5.50 13 12 14 479.25 2.44 .00 .00 3.06 5.43 15 14 16 474.30 2.40 .00 .00 3.03 5.32 17 16 32 862.77 3.22 .00 .00 5.51 16.12 I 19 18 16 391. 78 1. 49 .00 .00 2.50 3.74 21 20 18 395.08 1. 61 .00 .00 2.52 3.79 23 22 20 398.38 1.25 .00 .00 2.54 3.85 25 24 22 408.28 .77 .00 .00 2.61 4.03 I 27 4 24 408.28 1.01 .00 .00 2.61 4.03 29 22 26 6.60 .00 .00 .00 .04 .00 31 26 28 3.30 .00 .00 .00 .02 .00 I 33 32 30 6.60 .00 .00 .00 .04 .00 35 32 34 852.87 6.31 .00 .00 5.44 15.78 37 34 36 849.57 8.22 .00 .00 5.42 15.67 39 36 40 844.62 9.92 .00 .00 5.39 15.50 I 41 40 38 4.95 .00 .00 .00 .03 .00 43 42 40 -834.72 -2.65 .00 .00 -5.33 -15.16 45 42 44 1506.60 13.58 .00 .00 9.62 45.26 I 47 44 46 1503.30 6.76 .00 .00 9.59 45.08 49 48 42 676.83 4.88 .00 .00 4.32 10.28 51 50 48 681. 78 3.65 .00 .00 4.35 10.42 53 58 50 539.48 1.45 .00 .00 3.44 6.76 I 55 52 50 147.25 .23 .00 .00 .94 .61 57 54 52 152.20 .29 .00 .00 .97 .65 59 56 54 157.15 .28 .00 .00 1. 00 .69 I 61 58 56 157.15 .65 .00 .00 1. 00 .69 63 8 58 696.63 26.03 .00 .00 4.45 10.85 I JUNCTION NUMBER DEMAND GRADE LINE ELEVATION PRESSURE 2 .00 374.66 134.70 103.98 4 .00 373.61 122.70 108.73 6 .00 373.44 115.00 111.99 I 8 .00 373.17 117.00 111.01 I I I I I I I I I I I I I I I I I I I I 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 6 8 4 46 44 54 1. 65 3.30 4.95 3.30 3.30 3.30 3.30 .00 3.30 3.30 6.60 3.30 3.30 4.95 4.95 4.95 4.95 3.30 1503.30 4.95 4.95 4.95 4.95 .00 .00 MAXIMUM .00 .00 .00 MINIMUM 1503.30 3.30 4.95 373.55 372.32 369.87 367.48 368.97 370.59 371.84 372.60 371.84 371.84 364.25 364.26 357.94 349.72 339.80 339.80 337.15 323.57 316.81 342.03 345.68 345.91 346.20 346.48 347.13 PRESSURES 373.44 373.17 373.61 PRESSURES 316.81 323.57 346.20 THE NET SYSTEM DEMAND = 1589.10 144.00 159.50 180.10 188.90 169.80 150.00 130.30 127.20 132.20 136.90 194.50 188.90 217.00 233.80 248.80 245.10 244.40 251. 50 260.00 238.20 215.90 240.90 270.70 248.00 200.20 115.00 117.00 122.70 260.00 251. 50 270.70 99.47 92.22 82.24 77.38 86.31 95.59 104.67 106.34 103.84 101. 81 73.56 75.99 61.08 50.23 39.43 41. 04 40.19 31.23 24.62 44.99 56.24 45.51 32.72 42.67 63.67 111. 99 111. 01 108.73 24.62 31.23 32.72 SUMMARY OF INFLOWS(+) AND OUTFLOWS(-) FROM FIXED GRADE NODES PIPE NUMBER FLOWRATE 1 1589.10 THE NET FLOW INTO THE SYSTEM FROM FIXED GRADE NODES = THE NET FLOW OUT OF THE SYSTEM INTO FIXED GRADE NODES 1589.10 .00 A SUMMARY OF CONDITIONS SPECIFIED FOR THE NEXT SIMULATION FOLLOWS THE DEMANDS ARE CHANGED FROM ORIGINAL VALUES BY A FACTOR = 1.65 THE FOLLOWING SPECIFIC DEMAND CHANGES ARE MADE : JUNCTION NUMBER DEMAND 30 1506.60 I I I THE RESULTS ARE OBTAINED AFTER 4 TRIALS WITH AN ACCURACY .00157 I MAXIMUM DAILY DEMAND AND 1500 GPM FIRE FLOW AT NODE 30 I PIPE NO. NODE NOS. FLOWRATE HEAD LOSS PUMP HEAD MINOR LOSS VELO(::ITY HL/IOOO 1 0 2 158.9.10 .34 .00 .00 2.54 1. 71 3 2 4 948.86 .79 .00 .00 1. 51 .66 5 4 6 384.35 .06 .00 .00 .61 .12 I 7 6 8 384.35 .09 .00 .00 .61 .12 9 2 10 640.24 1.86 .00 .00 4.09 9.28 11 10 12 638.59 2.08 .00 .00 '4.08 9.23 I 13 12 14 635.29 4.12 .00 .00 4.05 9.14 15 14 16 630.34 4.06 .00 .00 4.02 9.01 17 16 32 1175.05 5.71 .00 .00 7.50 28.56 19 18 16 548.01 2.78 .00 .00 3.50 6.96 I 21 20 18 551.31 2.99 .00 .00 3.52 7.03 23 22 20 554.61 2.31 .00 .00 3.54 7.11 25 24 22 564.51 1. 40 .00 .00 3.60 7.35 27 4 24 564.51 1. 84 .00 .00 3.60 7.35 I 29 22 26 6.60 .00 .00 .00 .04 .00 31 26 28 3.30 .00 .00 .00 .02 .00 33 32 30 1506.60 23.76 .00 .00 9.62 45.26 I 35 32 34 -334.85 -1.12 .00 .00 -2.14 -2.79 37 34 36 -338.15 -1. 49 .00 .00 -2.16 -2.84 39 36 40 -343.10 -1. 87 .00 .00 -2.19 -2.92 41 40 38 4.95 .00 .00 .00 .03 .00 I 43 42 40 353.00 .54 .00 .00 2.25 3.08 45 42 44 6.60 .00 .00 .00 .04 .00 47 44 46 3.30 .00 .00 .00 .02 .00 I' 49 48 42 364.55 1. 55 .00 .00 2.33 3.27 51 50 48 369.50 1.17 .00 .00 2.36 3.35 53 58 50 296.73 .48 .00 .00 1. 89 2.23 55 52 50 77.72 .07 .00 .00 .50 .19 I 57 54 52 82.67 .09 .00 .00 .53 .21 59 56 54 87.62 .09 .00 .00 .56 .23 61 58 56 87.62 .22 .00 .00 .56 .23 I 63 8 58 384.35 8.65 .00 .00 2.45 3.61 JUNCTION NUMBER DEMAND GRADE LINE ELEVATION PRESSURE I 2 .00 374.66 134.70 103.98 4 .00 373.87 122.70 108.84 6 .00 373.81 115.00 112.15 8 .00 373.72 117.00 111. 25 I 10 1. 65 372.80 144.00 99.15 12 3.30 370.73 159.50 91. 53 14 4.95 366.61 180.10 80.82 I 16 3.30 362.55 188.90 75.25 18 3.30 365.34 169.80 84.73 20 3.30 368.33 150.00 94.61 22 3.30 370.64 130.30 104.15 I 24 .00 372.03 127.20 106.09 I I I I I I I I I I I I I I I I I I I 26 3.30 370.64 132.20 103.32 28 3.30 370.64 136.90 101. 29 30 1506.60 333.08 194.50 60.05 32 3.30 356.84 188.90 72.77 34 3.30 357.96 217.00 61. 08 36 4.95 359.45 233.80 54.45 38 4.95 361. 32 248.80 48.76 40 4.95 361. 32 245.10 50.36 42 4.95 361.86 244.40 50.90 44 3.30 361.86 251. 50 47.82 46 3.30 361. 86 260.00 44.14 48 4.95 363.41 238.20 54.26 50 4.95 364.59 215.90 64.43 52 4.95 364.66 240.90 53.63 54 4.95 364.75 270.70 40.76 56 .00 364.85 248.00 50.63 58 .00 365.07 200.20 71. 44 MAXIMUM PRESSURES 6 .00 373.81 115.00 112.15 8 .00 373.72 117.00 111.25 4 .00 373.87 122.70 108.84 MINIMUM PRESSURES 54 4.95 364.75 270.70 40.76 46 3.30 361.86 260.00 44.14 44 3.30 361.86 251.50 47;82 THE NET SYSTEM DEMAND 1589.10 SUMMARY OF INFLOWS(+) AND OUTFLOWS(-) FROM FIXED GRADE NODES PIPE NUMBER FLOWRATE 1 1589.10 THE NET FLOW INTO THE SYSTEM FROM FIXED GRADE NODES = 1589.10 THE NET FLOW OUT OF THE SYSTEM INTO FIXED GRADE NODES = .00 A SUMMARY OF CONDITIONS SPECIFIED FOR THE NEXT SIMULATION FOLLOWS THE DEMANDS ARE CHANGED FROM ORIGINAL VALUES BY A FACTOR = 2.90 THE RESULTS ARE OBTAINED AFTER 3 TRIALS WITH AN ACCURACY .00151 PEAK HOUR DEMAND PIPE NO. NODE NOS. 102 324 FLOWRATE 156.60 100.24 HEAD LOSS PUMP HEAD MINOR LOSS VELOCITY HL/1000 .00 .00 .00 .25 .02 .01 .00 .00 .16 .01 I I 5 4 6 44.57 .00 .00 .00 .07 .00 7 6 8 44.57 .00 .00 .00 .07 .00- I· 9 2 10 56.36 .02 .00 .00 .36 .10 11 10 12 53.46 .02 .00 .00 .34 .09 13 12 14 47.66 .03 .00 .00 .30 .08 15 14 16 38.96 .02 .00 .00 .25 .05 I 17 16 32 59.83 .02 .00 .00 .38 .12 19 18 16 26.67 .01 .00 .00 .17 .03 21 20 18 32.47 .02 .00 .00 .21 .04 I 23 22 20 38.27 .02 .00 .00 .24 .05 25 24 22 55.67 .02 .00 .00 .36 .10 27 4 24 55.67 .03 .00 .00 .36 .10 29 22 26 11. 60 .00 .00 .00 .07 .01 I 31 26 28 5.80 .00 .00 .00 .04 .00 33 32 30 11.60 .00 .00 .00 .07 .01 35 32 34 42.43 .02 .00 .00 .27 .06 I 37 34 36 36.63 .02 .00 .00 .23 .05 39 36 40 27.93 .02 .00 .00 .18 .03 41 40 38 8.70 .00 .00 .00 .06 .00 43 42 40 -10.53 .00 .00 .00 -.07 .00 I 45 42 44 11.60 .00 .00 .00 .07 .01 47 44 46 5.80 .00 .00 .00 .04 .00 49 48 42 9.77 .00 .00 .00 .06 .00 I 51 50 48 18.47 .00 .00 .00 .12 .01 53 58 50 32.39 .01 .00 .00 .21 .04 55 52 50 -5.22 .00 .00 .00 -.03 .00 57 54 52 3.48 .00 .00 .00 .02 .00 I 59 56 54 12.18 .00 .00 .00 .08 .01 61 58 56 12.18 .01 .00 .00 .08 .01 63 8 58 44.57 .16 .00 .00 .28 .07 I JUNCTION NUMBER DEMAND GRADE LINE ELEVATION PRESSURE 2 .00 375.00 134.70 104.13 I 4 .00 374.98 122.70 109.32 6 .00 374.98 115.00 112.66 8 .00 374.98 117.00 111. 79 10 2.90 374.97 144.00 100.09 I 12 5.80 374.95 159.50 93.36 14 8.70 374.92 180.10 84.42 16 5.80 374.90 188.90 80.60 18 5.80 374.91 169.80 88.88 I 20 5.80 374.92 150.00 97.47 22 5.80 374.94 130.30 106.01 24 .00 374.96 127.20 107.36 I 26 5.80 374.94 132.20 105.19 28 5.80 374.94 136.90 103.15 30 11. 60 374.87 194.50 78.16 32 5.80 374.87 188.90 80.59 I 34 5.80 374.85 217.00 68.40 36 8.70 374.82 233.80 61.11 38 8.70 374.81 248.80 54.60 I 40 8.70 374.81 245.10 56.21 42 8.70 374.81 244.40 56.51 44 5.80 374.80 251. 50 53.43 46 5.80 374.80 260.00 49.75 I 48 8.70 374.81 238.20 59.20 I I I I I I I I I I I I I I I I I I 50 8.70 374.81 215.90 68.86 52 8.70 374.81 240.90 58.03 54 8.70 374.81 270.70 45.12 56 .00 374.81 248.00 54.95 58 .00 374.82 200.20 75.67 MAXIMUM PRESSURES 6 .00 374.98 115.00 112.66 8 .00 374.98 117.00 111. 79 4 .00 374.98 122.70 109.32 MINIMUM PRESSURES 54 8.70 374.81 270.70 45.12 46 5.80 374.80 260.00 49.75 44 5.80 374.80 251. 50 53.43 THE NET SYSTEM DEMAND = 156.60 SUMMARY OF INFLOWS(+) AND OUTFLOWS(-) FROM FIXED GRADE NODES PIPE NUMBER FLOWRATE 1 156.60 THE NET FLOW INTO THE SYSTEM FROM FIXED GRADE NODES = THE NET FLOW OUT OF THE SYSTEM INTO FIXED GRADE NODES 156.60 .00 . -.'" CS2U:\681 024 \NGHBHO-6-7\EXHIBIT -AOWG 07-29-04 11 :23:01 \ \ ~ , '! II 'I I j il fi n \ \ l j ;: , L ; ! , ~---- BRESSI RANCH \ NOTE: ALL PIPES ARE 8" UNLESS OTHERWISE SHOWN --------- LEGEND - - -EXISTING WATER LINE --PROPOSED WATER LINE ~ COMPUTER MODEL NODE IT] COMPUTER MODEL PIPE FIRE HYDRANT DEXTER WILSON ENGINEERING, INC. CONSULTING ENGINEERS 703 PALOMAR AIRPORT ROAD, SUITE 300 CARLSBAD, CA 92009 (760) 438-4422 SCAL£: I" = 200' EXHIBIT A LA COSTA NEIGHBORHOODS 1 .06 NODE AND PIPE GREENS AND 1.07 DIAGRAM , , I I I i ,. ! !.