Loading...
HomeMy WebLinkAboutCT 05-13; LA COSTA RIDGE NBHGD 2.6; CLOMR-F; 2007-03-05I I I I I I I I I I I I I I I I I I I HUNSAKER &ASSOCIATES RECORD COpy DP-- :":"a...::!lI 5 AND lEG 0, INC. Initial PLANNING ENGINEERING SURVEYING IRVINE LOS ANGELES RIVERSIDE SAN DIEGO ARIZONA DAVE HAMMAR LEX WILLIMAN ALiSA VIALPANDO DAN SMITH RAY MARTIN CHUCK CATER 9707 Waples Street San Diego, CA 92121 (858) 558-4500 PH (858) 558-1414 FX www.HunsakerSD.com Info@HunsakerSD.com CONDITIONAL LETTER OF MAP REVISION BASED ON FILL (CLOMR-F) for LA COSTA RIDGE 2.6 City of Carlsbad, California Prepared for: Western Pacific Housing 5790 Fleet Street Suite 210 Carlsbad, CA 92008 W.O. 1751-136 March 5, 2007 Hunsaker & Associates San Diego, Inc. Ra ond L. Martin, R.C.E. Vice President DE kc h:\reports\17S1\136\clomnclomr_01.doc W 01751-136 3/6/20076:52 AM I' I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 . Conditional Letter of Map Revision Based on Fill TABLE OF CONTENTS Chapter 1 -Executive Summary 1.1 Introduction 1.2 Summary of Pre-Development Conditions 1.3 Summary of Developed Conditions 1.4 Summary of Results 1.5 References 1.6 FEMA MT-1 Form Chapter 2 -Floodplain Analysis Methodology (HEC-RAS) 2.1 Model Selection 2.2 Cross Section Data 2.2.1 Cross Section Locations 2.3 HEC-RAS Model Design Input Parameters 2.3.1 Starting Water Surface Elevations 2.3.2 Manning's Roughness Coefficients Chapter 3 -Pre-Developed Condition HEC-RAS Results 3.1 Pre-Developed Summary Table 3.1.1 Channel Cross Sections 3.1.2 Channel Profiles 3.1.3 Pre-Developed Condition HEC-RAS Report Chapter 4 -Developed Condition HEC-RAS Results 4.1 Developed Summary Table 4.1.1 Channel Cross Sections 4.1.2 Channel Profiles 4.1.3 Developed Condition HEC-RAS Report Chapter 5 -Pre-Developed Condition Floodplain Exhibit Chapter 6 -Developed Condition Floodplain Exhibit APPENDIX A -Site Plans for La Costa 2.6 SECTION II III IV V VI DE:de h:lrepor1s1175111361c1omrldomr_01.doc w.o.1751-136 3/5/20072:26 PM I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 . Conditional Letter of Map Revision Based on Fill List of Tables and Figures Chapter 1 -Vicinity Map Chapter 1 -FIRM 06037C1051 F Chapter 1 -Pre-Developed San Marcos Creek HEC-RAS Water Surface Elevations Chapter 1 -Pre-Developed Conditions Floodplain Exhibit Chapter 1 -Post-Developed San Marcos Creek HEC-RAS Water Surface Elevations Chapter 1 -Developed Conditions Floodplain Exhibit Chapter 1 -Pre vs. Post-Developed San Marcos Creek HEC-RAS Water Surface Elevations DE:de h:lreport51175111361c1omrlciomL01.doc W.O.17S1-136 3/5120072:26 PM I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 1 -EXECUTIVE SUMMARY 1.1 • Introduction The La Costa Ridge Neighborhood 2.6 project site is located west of Rancho Santa Fe Road at the intersection of Corintia Street and Melrose Drive intersection within the City of Carlsbad, California (see Vicinity Map on this page). San Marcos Creek is adjacent and to the south of the project site. VICINITY MAP AI!.SIDI lEm"AUI£ MAP 801JII/lARY /115 All runoff from the project site will drain to the adjacent San Marcos Creek. Runoff from the San Marcos Creek eventually discharges into the Batisquitos Lagoon. This Conditional Letter of Map Revision has been prepared per the request of the City of Carlsbad. This Conditional Letter of Map Revision was prepared as the La Costa 2.6 development is adjacent to the previously delineated FEMA floodplain (per FIRM Map No. 06037C1051 F). This portion of San Marcos Creek has a floodplain designation of Zone A, hence no previous detailed analysis exists. Per a previous Army Corps study a peak flow conveyance of approximately 13000 cfs was identified for the San Marcos Creek at this location. DE:de h:lreport51175111361clomrldomc01.doc w.o.1751·136 3/5/20072:26 PM ~ ~ so so 160 ,......--SCALE 1'=SO' I t 1 OF l5! LA COSTA RIDGE NEIGHBORHOOD 2.6 ... • _ \ '&~~ f / / ///~ __ ~~ ~ I / / ,,/ _.:.::-_ ----..... ~ '_. ~ I L .......... --r CITY OF CARLSBAD, CAUFORNIA 1! .. R'\0459\LHyd\04~9SHlO-EX'-rlRH.d.gt 2085]Ma.r-05-2007117~6 I 11 1 I 12 I I I 3 I I I 4 .1 1,_. I 15 I I 16 I A E B c o F 11'7°15'00" 33"01"30" I _ 1_ JOINS JAlla. 0788 ,1170~·~~:aT.30 .. 13 ZONE X 24 o 19 NOTE: MAP AREA SHOWN ON THIS PANEL IS LOCATED WITHIN TOWNSHIP 12 SOUTH. RANGE 4 WEST AND TOWNSHIP 12 SOUTH. RANGE 3 WEST. CITY OF CARLSBAD 060285 30 31 1 ~~ ~ SAN DIEGO COUNTY -MDMDm .... ~ CITY OF SAN MARCOS /' °1 ZONE X 20 _._. ____ COUNTY UNINCORPORATED AREAS 060284 ZONE X CITY OF SAN MARCOS 060296 'AN DIEGO COtlNTY---+--L UNn{CORPORATED ARElI.S 06Il284 32 ,. I 133"05'37" 111°U'01" LEGEND -5PEC1Al FlOOD HAZARD ARW INUNDA'IlD BY l00-YEAR flOOD No_bd~~ 17 a..l\Qodtlr.o6cm~ ZONlAH ~cf\!.l~~ Fb.d~cf1"11e.t;w-Dr'*" 1Iow""~beIIMII;_ ... dtpts ~rOl'_d..w1an1'o<.cd:r(. ...................... ZONtA9'J Tobopotl4td"""~ftoodby fcdota! a.;..d pII:IItCtio<I """"" undo< ~"'bM:~~ lON!Y CozoII\ood...w.~I\aQfd'- .Io<IIonI;'''''to..Aood ......... ~ ZONl!\'1I. CoasI.>IIoocI~....b:tthaunlt--E!E$¥l aab!I:buot.a-I"_~ ROODWAY AREAS IN ZONE AE OTHER flOOD AREAS ~tI~IIood;JNUd.~ Ioodwllh ....... <f.¢.od'103I1han lra.:.t ... """ohIn. __ ...... 100000lIIlIo;aId...,p!'OIoacdby "-''''''''Too,..,-fIoad. o OTHER AREAS _~"'b.DI.tIIdosm-,­...".... Jvutj"whIdo8ood~ .. .........." UNDEVELOPED COASTAl BARRIERS ~ f;,',,,j ~ 19D ~'"" 1'nlIec:ledhf,M Cou!aIl>Itrlltaraat ... fIOlI'NI!yml8<l".,tlllt,"'ad)tc:aoItlaSpet!ol ""'--.......... -'-z..n.DBOIO>6oI'1' 80undMy DMrSt>g SI>IdoIFIood Kwlll ZDt*, IJI"4 8o<IrdaIy DowIdC>g Neu 01 D<tIonnt toutoIlla&ooRood a...~ 'MtM SpeciII Flood tw.wd -BaM flood EJe.a\lon u .... --513--~~s..Malt""'- @-------@ emu s.aIooA I.kIa -I~~ ___ ._~~~~~.::::-_ SHMopln:l ...... a..._o. ....... RM7X a-tIorIfIeI_~ HoIhomooI~a....d""Nor:h 91"01'30",32022'30" Amo<Ic&nOltllmot1977I~271 "- NOTES nQ .... plolot .... kI~'C!wIW:nolR'>OdItmnnceI'n>;rlon: ItdMI"""~Id-'Y.S-.aslUb)tctt~fIordtIc.pan!cWrljfrDIII IocoId'''''''~llOlII1:eSgf_slra.ora!lpl.onir!'letrlcf_~ Sp<ocWfm.:!t'-nlN-. eo..wbuto1Soo411",,","",or:pItMIV~aI'o.otl(M).and~. lho.rt_crl_"'IoCborI:u...~ff*I'''QII" .. ~ Iforn ~ doyoloptd by Il'Ie Ndal'lll w.nt.s..n:.Ior""""""---.. "'-01 SpQ/RoodH&WdtlOD-'tMf' fIoodIlndJdoI ZonqA.~AAAO, A!l'J,v •• I'oIIVE. toN!n_notln~FIoodHl.=tdAnNt.,...,t..p!\lIKI6dbv IIoocIccnttdltrltCbds. Boo.1)I/fts"'m.~"""'~"'=»_and hIcrpo\oIcdbolwt.!ncn>l.l __ Tl-.~_.baodDII hydt.uJIc conald--. ""'" .""",nl1O """"""-_ af d'Io I'odmoI ErHrg-v~'-"'t, A~wodlhc In..-aou 1MYi»1ca NrrCW ta.tlOWtoac:att. flclodwatwO:!lhs ... proWw.IInIMAacd~SlIIc!yR-port. n.......,....,IoccrpameIippfCU;llI.hourIdar1eI.oICoutalIllfTlrlt R~SyJt.mUril!allltlw~I'nr!cct8d ...... ~ underu..Cou!BIe.n\ef~At:tafl99Cl\PL1OI-69I~ ~1ImlII.bcY.n"o..rflII. .. "'lhodateolthbtnlIl-The_ abouIcI<amq~camnl&lrityolfldall1OdoI'rmN"~ IO'htI hM c:Nncod .ubnQu0nl 10 1M '""'-01 IIU 1'lii/io FCIt~tn=jlroWIcnlistzJryprlortocourtt~~"'D So:IbrIlUlcl1MfIocd~tw6y'RDpOrt. hIf~lnrIppontlsandt..Mrr-.p __ ~prbtad "~- MAP REPOSITORY Raferta Repcsltory Ust/nll on !.up rnd~ Eff£CTlVE DATE OF COUHlYW!DE FlOOD INSURANce RATE MAP' EFfECTM. DAttlS)OF RevrsrONlSlTO nus PAAEI..: RoI .. llrtilllA.OOf)INSUIWICERATeIoWEFf£CItVE DATE~ OIIWomaplDdo\omIInow.t.rrldlllllolm .. apc>lylO_1n _1Ofww ........... ~'-t-nntalohhtd. To~HtIGocIn-Is...ww._*,hA.nnc:Iol9"l"-'" QII=-HIIIDnoIRoad~I'fo;tImIl!.I8OOl~ • APPROXIMATE SCALE IN FEET 500 , .. FIRM FLOOD INSURANCE RATE MAP .!!IMl!m.!'.!!if!.~ ---- MAP NUMBER 06073C10Sl F EFFECTIVE DATE: JUNE 19, 1997 ----'---'--..... ----------------------..:...--.-=-----======-____ -=-L ______ ~_~_~ ___ _ I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill 1.2 -Summary of Pre-Developed Conditions The La Costa Ridge Neighborhood 2.6 site is part of the La Costa Ridge development in the City of Carlsbad, California. The site has been mass graded 'in anticipation for residential development per the "Grading and Erosion Control Plans for La Costa Ridge Stockpile Plan" dated September, 2004 by Hunsaker & Associates. Per the "Mass Grading Hydrology Study for the Vii/ages of La Costa Neighborhoods 2.1 through 2.5" dated January, 2004 by Hunsaker & Associates, a 48-inch storm drain located within the adjacent Corintia Street conveys a flow of approximately 154 cfs from the neighboring La Costa Ridge Neighborhood 2.5. This 48-inch RCP storm drain discharges runoff into the project site, eventually draining overland and discharging to San Marcos Creek. Table 1 -Summary of Existing Peak Inflows Drainage Location Drainage Area 100-Year Peak Flow (Ac) (cfs) 48-inch RCP from 68.4 154.0 Neighborhood 2.5 The Regional Water Quality Control Board has identified San Marcos Creek as part of the Carlsbad Hydrologic Unit, San Marcos Hydrologic Area, and the Batiquitos Subarea (basin number 904.51). • \ j. > Table 2 summarizes the HEC-RAS model results for the calculated water surface elevations for the pre-developed San Marcos Creek at the La Costa 2.6 project site. Table 2 -Pre-Developed HEC-RAS Water Surface Elevations Cross Section Location 11 Upstream Limit 10.5 Bridge 10 9 8 Project Boundary 7 6 5 4 3 2 1 Downstream Limit HEC-RAS 100-Year Water Surface Elevation (ft) 338.41 337.02 336.25 335.88 335.08 334.08 333.10 331.92 330.59 328.27 323.71 DE:de h:\repor1s1175111361clorillldomc01.doc w.o.1751-136 3/5120072:26 PM I.: ..... 1 :.:>. I 1 I I I I I I I I I I I I I I I . La Costa Ridge 2.6 .' Conditional Letter of Map Revision Based on' Fill ," .. r .. ' A revised pre-developed floodplain exhibit for San Marcos Creek has been provided on the following page. 1.3 -Summary of Developed Conditions Development of the 11.2-acre area will consist of 54 single family residences, foot paths, communal open space and underground utilities with two (2) entrances from the adjacent Corintia Street. Runoff generated by the proposed La Costa Ridge Neighborhood 2.6 development will be conveyed in a southerly direction via curb and gutter within the proposed site, draining into two (2) curb inlets. Flow from the adjacent Neighborhood 2.5's 48-inch RCP storm drain will be conveyed south by a proposed storm drain system within the Neighborhood 2.6 site. The existing offsite flow will converge with flows from the developed Neighborhood 2.6 site, discharging into the receiving San Marcos Creek. Offsite runoff from the adjacent Corintia Street that previously drained to the proposed La Costa Greens 2.6 project site via two (2) existing curb inlets will be intercepted via two (2) proposed curb inlets within Corintia Street near the Private ·Street j,c" entranceway .. Flows will be conveyed via public storm drain through the project site (located within a public easement), confluencing with on site flows prior , to discharge from the project site. 'Per the "TM Drainage Study for La Costa Ridge 2.6" dated May, 2006 by Hunsaker & Associates, peak flow data from the developed site to the receiving San Marcos Creek is summarized in Table 3 below. , Table 3 -Summary of Post-Developed Conditions Drainage Location Drainage Area 100-Year Peak Flow (Ac) (cfs) 48-inch RCP to San 77.1* 174.5 Marcos Creek *= inclusive of Neighborhood 2.5 tnbutary Discharge to the receiving San Marcos Creek was analyzed per the "Preliminary Hydrology for Vii/ages of La Costa -The Ridge and the Oaks" dated April 2001, by Hunsaker & Associates. The proposed project will involve grading, elevating all residences above the ultimate condition 100 year floodplain. Grading will be conducted adjacent to the floodplain as delineated on the current FIRM. Table 4 summarizes the HEC-RAS model results for the calculated water surface elevations for the post-developed San Marcos Creek at the La Costa Ridge 2.6 project site. DE:de h:lreports\1751\136\clomilciomc01.doc w.o.1751-136 3/61200711:19 AM . ~1:' , 50 ~ ~ 50 100 ------ EXISTING FLOODPLAIN FIRM FLOODPLAIN FLOWLINE CROSS SECTION G DATUM NOTE: NGVD 1929VERTICAL DATUM USED SUIVl'tIIG~'~VI& LA COSTA RIDGE -NEIGHBORHOOD 2.6 CITY OF CARLSBAD, CAUFORNIA R.\04S9\LHyd\0459SH12-EX-HECRAS-dwg( // SHEET 1 OF 1 '" d " La Costa Ridge 2.9 Conditional Letter of'Map Revision Based on Fill Table 4 -Post-Developed HEC-RAS Water Surface Elevations Computed 100-Adjacent Road Cross Section Location Year Water Surface/Developed Surface Elevation Pad Elevation (ft) (ft) 11 Upstream Limit 338A1 NA 10.5 Bridge NA 10 337.03 NA 9 336.26 NA 8 Project Boundary_ 335.89 348.9 7 335.08 348.9 6 334.08 351.0 5 333.10 354.3 4 331.92 3!j5.7 3 330.59 358.6 2 328.27 359.5 1 Downstream Limit 323.71 NA 1.4 -Summary of Results Hydraulic computations were modeled using the HEC-RAS program for the water- surface profiles of the drainage channels. The 1 OO-year peak flow of 13000 cfs was used as the base flood for the San Marcos Creek hydraulic model. The HEC-RAS model was used to ascertain water surface elevations, flow velocities and the updated floodplain boundary. Table 5 summarizes the pre versus post-developed HEC-RAS model results for the calculated water surface elevations for the San Marcos Creek within the La Costa Ridge 2.6 site. DE:de h:\reporls\17S1\136\clomr\dom,_01.doc w.o.17S1-136 3/61200711:19 AM .r. ... ~ ~ 60 60 120 --------_ .. -... _. PROPOSED FLOODPLAIN EXISTING FLOODPLAIN FLOWLINE CROSS SECTION @ t' ..- ~ DATUM NOTE: NGVO 1929 VERTICAL DATUM USED HUNSAKER &ASSOCIATES S A Ie D If C Q. tie C. DEVELOPED FLOODPLAIN LA COSTA RIDGE NEIGHBORHOOD 2.6 CITY OF CARLSBAD, CAUFORNIA /" SHEET 1 OF 1 ~'04S9\~yd\04S9$Hll-DEV-H£CRAS.dwgt 20BSlHo.,.-OS-2.007114130 FEDERAL EMERGENCY MANAGEMENT AGENCY COMMUNITY ACKNOWLEDGMENT FORM PAPERWORK BURDEN DISCLOSURE NOTICE o'M.B. NO. 3tJ67-0147 Expires September 36, 2005 public reporting burden for this form is estimated to average 0.88 hour per response. The burden estimate includes the time for reviewing instructions, searching existing data sources, gathering and maintaining the needed data, and completing, reviewing, and submitting the form. You are not required to respond to this collection of information unless a valid OMB control number appears in the upper right corner of this form. Send comments regarding the accuracy of the burden estimate and any suggestions for reducing this burden to: Information Collections Management, Federal Emergen<,y Management Agency, 500 C Street. SW, Washington DC 20472, Paperwork Reduction Project (3067-0147). Submission of the form is required to .obtain or retain benefits under the National Flood Insurance Program. Please do not send your completed survey to the above address. This form must be completed for requests involving the existing or proposed placement of fill (complete Section A) .QR to provide acknowledgment of this request to remove a propertj from the SFHA which was previously located within the regulatory floodway (complete Section B). This fOr(l1 must be completed and signed by the official responsible for floodplain management in the community. The community number and the subject propertj address must appear in the spaces provided below. Community Number: Property Name or Address: A. REQUESTS INVOLVING THE PLACEMENT OF FILL As the community official responsible for floodplain management, I hereby acknowledge that we have reGeived and reviewed this Letter of Map ReVision Based on Fill (LOMR-F) or Conditional LOMR-F request. Based upon the community'S review, we find the completed or proposed project'meets' or is , ; designed to meet all of the community floodplain management requirements, il'lcluding the requirement that no fill be placed in the regulatory floodway., : and that all necessary Federal, State, and local permits have been, or in the case of a Conditional LOMR-F, will be obtained. In addition, we have ,determined that the land and any existing or proposed structures to be removed from the SFHA are orwill be reasonably safe from flooding'as defined in ,44CFR 65.2{c), and that we have available upon request by FEMA, all analyses and documentation used to make this determination, For LOMR-F ,requests, we understand that this request is being forwarded to FEMA for a possible map revision. , ) Community Comments: . ~:'to ormmunity Offic .. ial's Name and Title: (Please Pn'nt or fype) V ~elepho,\e No.: . o. ,\. 7~OJC,b2.,'2. 7 c,1 ;B. PROPERTY LOCATED WITHIN THE REGULATORY FLOORfVvAY ;' As 'the community o;icial responsible for floodplain managCent, I hereby acknowledge that we have received and rev;ewed this reque~t fora LOMA. :We understand thfjt this request is being forwarded to FEMA to determine if this property has been inadvertently included in the regulatory floodway. W~'acknowledge that no fill on this property has been or will be placed within the deSignated regulatory floodway. We find that the completed or . :.proposed project meets or is designed to meet all of the community floodplain management requirements. ~Community Comments: I· V, ~ !¢oll1munity Official's Name and Title: (Please Print or Type) Telephone N9.: F '~ ~, " i ': . 'ComrhunitY Name: t':'::· " .. , .;.. -' , , . :-,'-'. t;·., ':c. ''''', Community Official's Signature (required): Date: Community Acknowledgment Form MT~1 Form 3 Page 1 of 1 , I I I I I I I I I I I I I I I I I I I I • " La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill Table 5 -Pre vs. Post-Developed HEC-RAS Water Surface Elevations Pre-Developed Post-Developed Cross Computed 100-Computed 100-Difference Location Year Water Year Water Section Surface Surface Elevation (ft) Elevation (ft) (ft) 11 Upstream Limit 338.41 338.41 0 10.5 Bridge 0 10 337.02 337.0~ + 0.01 9 336.25 336.26 + 0.01 8 Project Boundary 335.88 335.89 + 0.01 7 335.08 335.08 ·0 6 334.08 334.08 0 5 333.10 333.10 0 4 331.92 331.92 0 3 330.59 330.59 0 2 328.27 328.27 , 0 1 Downstream Limit 323.71 323.71 0 HEC-RAS model creation methodology is located in Chapter 2 of this report. HEC- RAS cross section data, summary tables and program output files are located in Chapters 3 & 4. Based upon the results of HEC-RAS analysis, the proposed La Costa Ridge 2.6 development has been elevated several feet above the adjacent floodplain. 1.5 -References "San Diego County Hydrology Manual': County of San Diego Department of Public Works -Flood Control Section; June 2003. "TM Drainage Study for La Costa Ridge 2.6': Hunsaker & Associates, May 2006. "Preliminary Hydrology for Vii/ages of La Costa -The Ridge and the Oaks" j Hunsaker & Associates; April 2001. "Mass Grading Hydrology Study for the Vii/ages of La Costa Neighborhoods 2.1 through 2.5", Hunsaker & Associates; January 2004. DE:de .h:\reports\1751\136\clomrldomr_01 doc w.o.17S1-136 3/61200711:19 AM I I I I I I I I I I I I I I I I I I I FEDERAL EMERGENCY MANAGEMENT AGENCY PROPERTY INFORMATION FORM PAPERWORK BURDEN DISCLOSURE NOTICE OMB. NO. 3067-0147 Expires September 30, 2005 Public reporting burden for this form is estimated to average 1.63 hours per response. The burden estimate includes the time for reviewing instructions, searching existing data sources, gathering and maintaining the needed data, and completing, reviewing, and submitting the form. You are not required to respond to this collection of information unless a valid OMB control number appears in the upper right corner of this form. Send comments regarding the accuracy of the burden estimate and any suggestions for reducing this burden to: Information Collections Management, Federal Emergency Management Agency, 500 C Street, SW, Washington DC 20472, Paperwork Reduction Project (3067-0147). Submission ofthe form is required to obtain or retain benefits underthe National Flood Insurance Program. Please do not send your completed survey to the above address. This form may be completed by the property owner, property owner's agent, licensed land surveyor, or registered professional engineer to support a request for a Letter of Map Amendment (LOMA), Conditional Letter of Map Amendment (CLOMA), Letter of Map Revision Based on Fill (LOMR-F), or Conditional Letter of Map Revision Based on Fill (CLOMR-F) for existing or proposed, single or multiple lots/structures. Please check the item below th at describes you r reQU est D LOMA D CLOMA D LOMR-F ~ CLOMR-F A letter from FEMA stating that an existing structure or parcel of land that has not been elevated by fill (natural grade) would not be inundated by the base flood. A letter from FEMA stating that a proposed structure that is not to be elevated by fill (natural grade) would not be inundated bv the base flood if built as proposed. A letter from FEMA stating that an existing structure or parcel of land that has been elevated by fill would not be inundated by the base flood. A letter from FEMA stating that a parcel of land or proposed structure that will be elevated by fill would not be inundated by the base flood if fill is placed on the parcel as proposed or the structure is built as proposed. 8lLis defined as material from any source placed to raise the ground to or above the Base Flood Elevation (BFE). The common construction practice of removing unsuitable eXisting material (topsoil) and backfilling with select structural material is not considered the placement of fill if the practice does not alter the existing (natural grade) elevation, which is at or above the BFE. Fill that is placed before the date of the first National Flood Insurance Program (NFIP) map showing the area in a Special Flood Hazard Area (SFHA) is considered natural grade. Has fill been placed on your property? D Yes ~NO If yes, when was fill placed? Will fill be placed on your property? [0"Yes D No If yes, when will fill be placed? 1. Street Address of the Property (if request is for multiple structures, please attach additional sheet): WA month/year ~ 107 month/year 2. Legal description of Property (Lot, Block, Subdivision) (if a street address cannot be provided): APN 22 &-72-0 -o~ 3. Are you requesting that the SFHA designation be removed from (check one): D the entire legally recorded property? ~ a portion of land within the bounds of the property (a certified metes and bounds description and map of the area to be removed, certified by a licensed land surveyor or registered professional engineer, are required)? D structures on the property? What are the dates of construction? 4. Is this request for a (check one): D single structure g~glelot . lli multiple structures (How many structures are involved in your request? List the number: S"~ ) D multiple lots (How many lots are involved in your request? List the number: ) FEMA Form 81-87, SEP02 Property Information Form MT-1 Form 1 Page 1 of2 I I In addition to this form (MT-1 Form 1), ALL requests must include the following: I I I I I I I I I I I I I I I I • Copy of the Plat Map for the property (with recordation data and stamp of the Recorder's Office) OR • Copy of the property Deed (with recordation data and stamp of the Recorder's Office), accompanied by a tax assessor's map or other certified map showing the surveyed location of the property relative to local streets and watercourses • Copy of the effective FIRM panel ancllor Flood Boundary and Floodway Map (FBFM) (if applicable) on which the property location has been accurately plotted (property inadvertently located in the NFIP regulatory floodway will require Section B of MT-1 Form 3) • Form 2 -Elevation Form. If an Elevation Certificate has already been completed for this property, it may be submitted in addition to Form 2. Please include a map scale and North arrow on all maps submitted. For LOMR-Fs and CLOMR-Fs, the following must be submitted in addition to the items listed above: • Form 3 -Community Acknowledgment Form Processing Fee (see instructions for appropriate mailing address; or, visit http://www.fema.govlplan/preventJfhmlfrmJees.shtm for the most current fee schedule) Revised fee schedules are published periodically, but no more than once annually, as noted in the Federal Register. Please note: single/multiple lot(s)/structure(s) LOMAs are fee exempt. The current review and processing fees are listed below: Check the fee that applies to your request: D $325 (single lot'structure LOMR-F following a CLOMR-F) o $425 (single lot'structure LOMR-F) o $500 (single lot'structure CLOMA or CLOMR-F) [J $700 (multiple lot/structure LOMR-F following a CLOMR-F, or multiple lot'structure CLOMA) 1Q($800 (multiple lot'stru~ture LOMR-F or CLOMR-F) Please submit the Payment I nformation Form for remittance of applicable fees. Please make your check or money order payable to: National Flood Insurance Program. All documents submitted in support of thiS request are correct to the best of my knowledge. I understand that any false statement may be punishable by fine or imprisonment under Title 18 of the United States Code, Section 1001. ,\ 1 ~ 1> -f"'>.... I • W~ 1I 1iiGthc:.. Hi>l.(g' [VaG. I db r- Company: Pt2. l~~ :. _ ~ I a Applicant's Name: WV\A~'1 ~~b~ Please Print or Type Mailing Address: Daytime Telephone NO·:(t Cc 0) q"2,..'1-I ~OO E-Mail Address: Fax No.: (optional) Date Signat~pp'tant (required) If you have any questions concerning FEMA policy, or the NFIP in general, please contact the FEMA Map Assistance Center toll free at 1-877-FEMA MAP (1-877-336-2627), or visit the Flood Hazard Mapping website at http://www.femagov/planlpreventJfhm. FEMA Form 81·87, SEP 02 Property Information Form MT·1 Form 1 Page 2 of2 I I I I I I I I I I I I I I I I I I I FEDERAL EMERGENCY MANAGEMENT AGENCY ELEVATION FORM PAPERWORK BURDEN DISCLOSURE NOTICE o.Mil. NO. 3067-0147 Expires September 30, 2005 Public reporting burden for this form is estimated to average 1 hour per response. The burden estimate includes the time for reviewing instructions, searching existing data sources, gathering and maintaining the needed data, and completing, reviewing, and submitting the form. You are not required to respond to this collection of information unless a valid OMB control number appears in the upper right corner of this form. Send comments regarding the accuracy of the burden estimate and any suggestions for reducing this burden to: Information Collections Management, Federal Emergency Management Agency, 500 C Street, SW, Washington DC 20472, Paperwork Reduction Project (3067-0147). Submission of the form is required to obtain or retain benefits underthe National Flood Insurance Program. Please do not send your completed survey to the above address. This form must be completed for requests and must be completed and signed by a registered professional engineer or licensed land surveyor. A FEMA National Flood Insurance Program (NFIP) Elevation Certificate may be submitted in addition to this form for single structure requests. For requests to remove a structure on natural grade OR on engineered fill from the Special Flood Hazard Area (SFHA), submit the lowest adjacent grade (the lowest ground touching the structure), including an attached deck or garage. For requests to remove an entire parcel of land from the SFHA, provide the lowest lot elevation; or, if the request involves an area described by metes and bounds, provide the lowest elevation with'in the metes and bounds description. 1. NFIP Community Number: 0<002.9 C-Property Name or Address: LeJv c..~\-4-~ ~ce;(,..t.; ./L·b 2. Are the elevations listed below based on D eXisting or [2(proposed conditions? (Check one) 3. What is the elevation datum? If any of the elevations listed below were computed using a datum different than the datum used for the effective Flood Insurance Rate Map (FIRM) (e.g., NGVD 29 or NAVD 88), what was the conversion factor? N Gt(V 'P 2.. If Local Elevation +/. ft. = FIRM Datum 4. For the existing or ~sed structures listed below, what are the types of construction? (check all that apply) D crawl space slab on grade D basement/enclosure D other (explain) 5. Has FEMA identified this area as subject to land subsidence or uplift? (see instructions) DYes @NO If yes, what is the date of the current releveling? / (month/year) Lowest Lot Number Block Lowest Lot Adjacent Base Flood Number Elevation Grade To Elevation For FEMA Use Only Structure fCt> ':2..':2.-:!I '3.~a·t:f 'aIfS'O '6 '!.S. &q l~ Z. '2...']. -a~S' q 3~B·O -a '&.s-. 0 '1 " '2.'2-30 '6'i'I.O aCO·O 'eU£(· 0'(" This certification is to be signed and sealed by a licensed land surveyor, registered professional engineer, or architect authorized by law to certify elevation information. All documents submitted in support of this request are correct to the best of my knowledge. I understand that any false statement may be punishable by fine or imprisonment under Title 18 of the United States Code, Section 1001. Certifier's Name: :l2. (;V'1I M., f?I/' +; _ License No.: 4-f 6 -r 0 Expiration Date: C,/~o(o~ . Company N~e~ 1I~'S~.f Mt'"oc104 Telephone No.: 'Cff"-C-r-f'-&fl'OQ Fax No.: fM"'F -"t'S""& -{'f (~ Signature: ~.-., .-fk /jAr:. 1-Date: 'O{-' (07 U Seal (optional) FEMA Form 81~7A, SEP 02 Elevation Form MT·1 Form 2 Page 1 of2 I I I I I I I I I I I I I I I' I I I Continued from Page 1. Block Lowest Lot Lowest Base Flood Lot Number Number Elevation Adjacent Grade Elevation For FEMA Use Only To stru ctu re 7 ~2.3 3S'f.~ '6$'If'.O 3aa'lo ~ 2-.2. ',!, 3Sl' ., gs~.o $'&\·01"2- q 2'2..'3 '6c;g.~ :>58 ·0 '!.30.~c:t '2-l-2.':!» J('~. S' 5~Cf. 0 '3;2.9· 2-7 This certification is to be signed and sealed by a licensed land surveyor, registered professional engineer, or architect authorized by law to certify elevation information. AI! documents submitted in support of this request are correct to the best of my knowledge. I understand that any false statement may be punishable by fine or imprisonment under Title 18 of the United States Code, Section 1001. Certifier's Name: ~ iUotrj!. __ License No.: ~b70 Expiration Date: e,,( 1. 0 10 If" Company ~me: e./(.fI'\Vrc::(~ ..f Arroc,.'~ .... Telephone No.:~ f--J""S' ~-"t"S'oa Fax No.: Y1''r-')~ i"-Ict(l{- Signature: cb.~ ...... JZ~C Date: %(,(07 ~ (j .,. Seal (optional) FEMA Form 81-87A, SEP 02 Elevation Form MT·1 Form 2 Page 2 of2 I I I I I I I I I I I I I I I I I I I FEDERAL EMERGENCY MANAGEMENT AGENCY COMMUNITY ACKNOWLEDGMENT FORM PAPERWORK BURDEN DISCLOSURE NOTICE O.M.B. NO. 3067-0147 Expires September 30, 2005 Public reporting burden for this form is estimated to average 0.88 hour per response. The burden estimate includes the time for reviewing instructions, searching existing data sources, gathering and maintaining the needed data, and completing, reviewing, and submitting the form. You are not required to respond to this collection of information unless a valid OMB control number appears in the upper right corner of this fonm. Send comments regarding the accuracy of the burden estimate and any suggestions for reducing this burden to: Information Collections Management, Federal Emergency Management Agency, 500 C Street, SW, Washington DC 20472, Paperwork Reduction Project (3067-0147). Submission of the form is required to obtain or retain benefits under the National Flood Insurance Program. Please do not send your completed survey to the above address. This form must be completed for requests involving the existing or proposed placement of fill (complete Section A) OR to provioe acknowledgment of this request to remove a property from the SFHA which was previously located within the regulatory floodway (complete Section B). This fonm must be completed and signed by the official responsible for floodplain management in the community. The community number and the subject property address must appear in the spaces provided below. Community Number: Property Name or Address: A. REQUESTS INVOLVING THE PLACEMENT OF FILL As the community official responsible for floodplain management. I hereby acknowledge that we have received and reviewed this Letter of Map Revision Based on Fill (LOMR-F) or Conditional LOMR-F request. Based upon the community's review, we find the completed or proposed project meets or is designed to meet all of the community floodplain management requirements, including the requirement that no fill be placed in the regulatory floodway, and that all necessary Federal, State, and local permits have been, or in the case of a Conditional LOMR-F, will be obtained. In addition, we have determined that the land and any existing or proposed structures to be removed from the SFHA are orwill be reasonably safe from flooding as defined in 44CFR 65.2(c), and that we have available upon request by FEMA, all analyses and documentation used to make this determination. For LOMR-F requests, we understand that this request is being forwarded to FEMA for a possible map revision. Community Comments: Community Official's Name and Title: (Please Print or Type) Telephone No.: Community Name: Community Official's Signature: (required) Date: B. PROPERTY LOCATED WITHIN THE REGULATORY FLOODWAY As the community official responsible for floodplain management, I hereby acknowledge that we have received and reviewed this request for aLOMA. We understand that this request is being forwarded to FEMA to determine if this property has been inadvertently included in the regulatory floodway. We acknowledge that no fill on this property has been or will be placed within the designated regUlatory floodway. We find that the completed or proposed project meets or is designed to meet all of the community floodplain management requirements. Community Comments: Community Official's Name and Title: (Please Print or Type) Telephone No.: Community Name: Community Official's Signature (required): Date: FEMA Form 81·87B, SEP 02 Community Acknowledgment Form MT-1 Form 3 Page 1 of 1 I I I I I I I I I I I I I I I I I I I Community Name: Project Identifier: FEDERAL EMERGENCY MANAGEMENT AGENCY PAYMENT INFORMATION FORM CA ~ 0 -?-c..-o..r-\" bo-o<' L ov (..0 '\ +-<7\,./ <:i2-< o{.~ ...e---' 1-. ~ "~------~---------------------+-.------------------------------------~ lHIS FORM MUST BE MAILED, ALONG WIlH lHE APPROPRIAlE FEE, 10 lHE ADDRESS B8..0W OR FAXED 10 lHE FAX NUMBER BELOW, Type of Request: ~T-1 application } D MT-2 application D EDR application } Request No,: _____ _ (if known) FEMA Fee Charge System Administrator P.O, Box 22787 Alexandria, VA 22304 FAX (703) 317-3076 FEMA Project Library 3601 Eisenhower Avenue Alexandria, VA 22304 FAX (703) 751-7391 Amount: ~'8" 0 D INITIAL FEE' D FINAL FEE D FEE BALANCE" D MASTER CARD D VISA U2('CHECK D MONEY ORDER 'Note: Check only for EDR and/or Alluvial Fan requests (as appropriate), "Note: Check only if submitting a corrected fee for an ongoing request. COMPLETE lHlS SECTION ONL V IF PAVING BV CREDIT CARD CARD NUMBER I I I I 1-/ I I I I-I I I I I 1 2 3 4 5 6 7 8 9 10 11 12 Date NAME (AS IT APPEARS ON CARD)' (please print or type) $ ADDRESS: (for'your credit card receipt-please print or type) DAYTIME PHONE: I I I I I 13 14 15 16 Signature FEMA Form 81·107 Payment Information Form EXP.DATE CD CD Month Year I I I EXHIBIT "A" LEGAL DESCRIPTION A PORTION OF LOT 223 LYING WITHIN THE BOUNDARY OF CITY OF CARLSBAD I TRACT 99-04-02, VILLAGES OF LA COSTA -LA COSTA RIDGE, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, ACCORDING TO MAP I THEREOF NO. 14838, FILED IN THE OFFICE OF THE SAN DIEGO COUNTY RECORDER, JULY 14, 2004 AS FILE NO. 2004-0655633, OF OFFICIAL RECORDS, BEING MORE I I I I I I I I I I I I I I PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHEAST CORNER OF LOT 233 OF MAP 14379 IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALIFORNIA, FILED IN THE OFFICE OF THE SAN DIEGO COUNTY RECORDER, APRIL 29, 2002 AS FILE NO. 2002-0358064, OF OFFICIAL RECORDS; THENCE ALONG THE NORTHERLY LINE OF SAID LOT 233, SOUTH 65°28'00" WEST, 256.41 FEET; THENCE LEAVING SAID NORTHERLY LINE, NORTH 24°32'00" WEST, 25.97 FEET; THENCE NORTH 64°35'00" EAST, 191.04 FEET; THENCE NORTH 16°10'00" EAST, 80.83 FEET; THENCE NORTH 30°20'00" EAST, 71.68 FEET; THENCE SOUTH 6rOO'00" EAST, 14.96 FEET TO THE CENTERLINE OF THE ROAD EASEMENT PER DOCUMENT RECORDED APRIL 7, 1966 AS DOCUMENT NO. 58549 OF OFFICIAL RECORDS; THENCE ALONG SAID CENTERLINE SOUTH 00°31'43" WEST, 118.88 FEET TO THE BEGINNING OF A TANGENT 400.00 FOOT RADIUS CURVE, CONCAVE EASTERLY, THENCE SOUTHERLY ALONG THE ARC OF SAID CURVE THROUGH A CENTRAL ANGLE OF 01°59'47" A DISTANCE OF 13.94 FEET TO THE POINT OF BEGINNING. CONTAINING 0.293 ACRES, MORE OR LESS. APN 223-720-03 ~~ 3. <>t:.·Z<>07 ~ . AMBLER L.S. 7322 HUNSAKER & ASSOCIATES SAN DIEGO, INC. :M:\1751\136\Legal Description\A01.doc WO 1751-136 3/6/07 PAGE 1 OF 1 L.S. 7322 I EXHIBIT B PORTION OF LOT 223 -MAP NO. 14838 I 0 100 200 I \ ( 300 ~ ! I SCALE 1"= 100' \ 1 I I I I I I \ \ \ \ \ \ MAP NO. 14B3B \ 223 \ APN 223-720-03 \ \ N24"32'OO"W 25.97' I MAp 14319 L01 233 POB NE COR LOT 233 ~ ;;. L ROAD EAS. 4/7/1966, F/P. 58549, O.R. ~ 1:.=01"59'47" R=400.00' \ L=13.94' \ \ !:I§?"J C!2Q.''f(Bl II~------------------------------~ I I I I 1-= HUNSAKER I ~~~~9f~!ES CARLSBAD ) I VICINITY MAP ~~~~~~~ ____ ~ ________ ~N~.T.~.£~ ________ ~ I I I I I I I I I, I I I' ' I I . I I I I I , .. ! I . II \ ~ . . . ", I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 . Conditional Letter of Map Revision Based on Fill CHAPTER 2 FLOODPLAIN ANALYSIS METHODOLOGY HEC-RAS DE:de h:lrepoitsI175111361c1omrlclom,_01.doc w.o.1751·136 3/5120072:26 PM I I I I I I I I I I I I I· I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 2 METHODOLOGY -FLOODPLAIN ANALYSIS 2.1 Model Selection HEC-RAS River Analysis System This software allows for the modeling water surface profiles for one-dimensional steady gradually-varied flow. The basic computational procedure is based upon the solution of the one-dimensional energy equation. Energy losses are evaluated by friction (Manning's equation) and contraction/expansion (coefficient multiplied by the change in the velocity head). The momentum equation is used in situations where the water surface profile is rapidly varied. These situations include mixed-flow regime calculations (such as hydraulic jumps), hydraulics of bridges, and evaluating profiles at river confluences. The effects of various obstructions such as bridges, culverts, weirs, and structures in the floodplain may be considered in the computations. This software is designed for the computation of FEMA floodplain boundaries and floodway encroachments. 2.2 Cross Section Data Cross Section Locations Hydraulic model cross sections are generally taken where a change in channel geometry or a flow change takes place. Cross sections for this analysis have been taken approximately every fifty (50) feet. . Where bridges, culverts, or other obstructions block the flow path, a lower cross section interval is necessary. 2.3 HEC-RAS Model Design Input Parameters Starting Water Surface Elevations Boundary conditions are necessary to establish the starting water surface elevation at the upstream and downstream ends of a river system. A starting water surface elevation is necessary for the program to begin calculations. In a subcritical flow regime, boundary conditions are necessary at the downstream end of the river system. Supercritical flow regimes require boundary conditions at the upstream end of the river system. In a mixed-flow regime, boundary conditions are required at both the upstream and downstream ends. DE:de h:lreporlsI175111361clomrldom,_01.doc w.D.175M36 3fS120072:26PM I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill The four types of boundary conditions are: 1. Known Water Surface Elevation 2. Critical Depth 3. Normal Depth 4. Rating Curve In this analysis, as no existing FEMA study exists for the San Marcos Creek at this location, upstream and downstream known water surface elevations are unknown. Hence, a normal depth calculation was applied for the downstream water surface elevation and upstream critical depth slope was used in the developed conditions analysis for the San Marcos Creek analysis. Manning's Roughness Coefficients Manning's values ranging from 0.035 to 0.1 were used to represent the proposed developed graded and existing embankments of the San Marcos Creek. DE:de h:\reporlsI175111361c1omrldomr_01.doc w.o.1751-136 3/5/20072:26 PM I I I I I~ III I I I I I I I I, I I I I I I I I I I I I I I: I· I I I I I I. I I I '" I -...... I I I I I I I I I I I I I I I I I I . I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 3 PRE-DEVELOPED CONDITIONS HEC-RAS RESULTS DE:de h:lrepoTtsI17511136\clomrldom,-01.doC w.o.1751·136 3/5/29072:26 PM I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 3.1 PRE-DEVELOPED SUMMARY TABLE DE:de h:\reports\1751\136\clom~clomr_Ol.doc w.o.17S1-136 31S120072:26 PM --- ---- ----------- HEC-RAS Plan: Existing River: San Marcos Creek Reach: 1 Profile: PF#1 ;;-'?R~"~G~ [.~ D~~li~r,;$J~] i :\;0pi~fiI~~~::: r<Q~]Q[~E ~ f~Mllj;:~~;~~·:' ::~Wffu~~J~i::; :'F¢[it~;§~) :s~~:13:;~l~y,:j >l~'{$}.~~R~tt&~.~ (Mi(~i1tiec~~F;j§.wY&i~~l2~ ;'~iqIiWT~tii'~: :iE!if9.@:~6nU ~.:;'<~;,::' ~t; :~;';~~( ~:}:Xy,::~,:,,,~;;:: O:',·~\~~ ?~f,,):;T:;~ (::?:(cf~f2i~" ~'~:-"~;~@r:~?} ,,:~L,;~~(t!}:~':<::S :":/:~;({tL~~. ~ ::;::;::j(ftr;!~~} ~ ,f:~'tMtE;{~:, '~:~~~;~@§)J::;~3 '::~«§~lJ,tf! f;~~' ~?:~::~Hij~~ :~~:~ ;I)?;· ~,rT:" ":"~. ", ," '. rj:;~!-~~;.:){.;~;.r~~W:'~i:f~d-:;~Jff:#,f:;;;'?,:,:· 13000,00 323,50 338,41 332.22 338,86 0,007506 5.42 2410,28 289,09 0,32 51jj:-:i:~§~E~I;1J),j.$:;;::~1< ~~~. f:::. -,; ';;J:.~;. :,-: -:, Bridge ',.· __ -.n_ ..... <.~,,' ... _ "'." .. ~ .. _.~,, __ ~,'_e._ ... ~-~"'.'"~, .~.~n~". ~ {~~:·~':;.:::~\:·;;I;~r(;'~~~:':./'lpFih":" 1 13000,001 320.401 335,881 336,271 0,0055621 5,181 2667.881 544,131 0,29 'j::~:: ~'r:;~-H:7~'·"::;.:-.' ;;'·IPF#1;:'-., 13000,001 319,721 335.081 335,521 0,0070301 5.961 2660.801 390.631 0,32 1~·::-·'~':~.~:T6":":·,'·~: ~'IPF#1 13000,001 318.60\ 334,081 334,69\ 0,0093091 6,321 2136,271 271,721 0.36 0.40 0.44 0,43 0.55 1.;·,~·'~T:'h:':-· ,',IPF#1 13000,00\ 311,761 323.711 323,711 328,291 0,0081681 17,281 773,681 90,761 0.96 - I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 3.1·.1 CHANNEL CROSS SECTIONS DE:de h:lrepor1s1175111361c1omrlclomr_01.doc w.o.1751-136 3/5/20072:26 PM -- g c 0 ~ > Q) W g c 0 ~ > Q) ill -- - ----- San Marcos Creek-Existing Plan: Existing 3/5/2007 River = San Marcos Creek Reach = 1 RS = 11 350 .1 ~I( .1 )I( .1 1 345-1 / 3401 \ I 335 }, ... .. + ' 330 325 320 850 900 950 1000 1050 1100 1150 1200 1250 Station (ft) San Marcos Creek-Existing Plan: Existing 3/5/2007 River = San Marcos Creek Reach = 1 RS = 10.5 BR 355 ~.1 + .1 )~.H~ 350 345 ~t n'on,,,', ',,:,r 'i'/ ~ ,,: l: 340 :::"'r t:J I~ 1 335 I:' ;, " 330 + .. , It'~1 ~ 325 l'i 320 Legend WS PF#1 '''+, " Crit PF#1 • Ground • Bank Sta Legend WS PF#1 " .. " + " Crit PF#1 Ground • Bank Sta 700 800 900 1000 1100 1200 Station (ft) g c .Q ro > Q) W g c 0 ~ ~ W - -- --- -- 355 350 345 340 335 330 325 San Marcos Creek-Existing Plan: Existing 3/5/2007 River = San Marcos Creek Reach = 1 RS = 10.5 BR ~.1 + .1 + .11 "" ~,'l "---'~f-------+_ .... 320 I I I I I I I I I Legend WS PF#1 ---+. _ ... ""._- Crit PF#1 Ground • Bank Sta 850 900 950 1000 1050 1100 1150 1200 1250 Station (ft) San Marcos Creek-Existing Plan: Existing 3/5/2007 River = San Marcos Creek Reach = 1 RS = 10 Cross Section #10 , .1-+ .1 +.1..J 350-• I 345 340 335 330 325 320 700 800 900 1000 1100 1200 Station (ft) Legend WS PF#1 Ground " Bank Sta - -- g c: 0 ~ > Q) ill g c: o ~ Q) ill ------- ------ - -- San Marcos Creek-Existing Plan: Existing 3/5/2007 River = San Marcos Creek Reach = 1 RS = 9 Cross section #9 370 .1-+-.1-+-.1---1 360~ ~ 350 340 330 320 I I T7 700 800 900 1000 Station (ft) 1100 1200 1300 San Marcos Creek-Existing Plan: Existing 3/5/2007 Legend WS PF#1 • Ground • Bank Sta River:: San Marcos Creek Reach = 1 RS = 7 Cross-Section #7 380 .1-+-.1 + .1 >1 370 360 350 340 330 320 310 I , , , " , , , i Legend WS PF#1 Ground • Bank Sta 600 700 800 900 1000 1100 1200 1300 1400 Station (ft) San Marcos Creek-Existing Plan: Existing 3/5/2007 River = San Marcos Creek Reach = 1 RS = 8 Cross section #8 .1-+-.1~.1 >1 Legend WS PF#1 Ground ~ g 350 Ineff • Bank Sta c: o ~ ill g c: o ~ ill 600 800 1000 1200 1400 1600 Station (ft) San Marcos Creek-Existing Plan: Existing 3/5/2007 River = San Marcos Creek Reach = 1 RS = 6 Cross-Section #6 400 i( .1 + .1-+-.14 380 360 340 320 300-r1 ;;o-r-r--r-;;r,,~""""'""",,-:!"::",.....--.-'---.-.---.-..... -,---;r-r-~-400 600 800 1000 1200 1400 Station (ft) Legend WS PF#1 Ground • Bank Sta - ----,---- - - -- --- --_.- San Marcos Creek-Existing Plan: Existing 3/5/2007 River = San Marcos Creek Reach = 1 RS = 5 Cross-Section #5 g c 0 ~ > Q) iIi 400 IE .1-+-.1 ~.1---1 380 360 340 320 300 400 600 800 1000 1200 1400 Station (ft) San Marcos Creek-Existing Plan: Existing 3/5/2007 Legend WS PF#1 Ground • Bank Sta River = San Marcos Creek Reach = 1 RS = 3 Cross-Section #3 400 380 g 360 c o ~ .!!1 340 w 320 .1-+-.1 + .1 , 300 I I I I I I I I I 700 800 900 1000 1100 1200 1300 1400 1500 Station (ft) Legend WS PF#1 Ground • Bank Sta San Marcos Creek-Existing Plan: Existing 3/5/2007 RS = 4 Cross-Section #4 River = San Marcos Creek Reach = 1 400 380 g 360 c o ~ ~ 340 w 320 .1 + .1 ~.1~ 300 I I I I I I I I I 600 700 800 900 1000 1100 1200 1300 1400 Station (ft) San Marcos Creek-Existing Plan: Existing 3/5/2007 Legend WS PF#1 Ground • Bank Sta River = San Marcos Creek Reach = 1 RS = 2 Cross-Section #2 400-r-.1-+-.1 + .1 , 380 g 360 c o ~ .!!1 340 w 320 300 I I I I I I I I I 800 900 1000 1100 1200 1300 1400 1500 1600 Station (ft) Legend WS PF#1 Ground • Bank Sta -- g c o ~ (j) iIi - -- - ---- San Marcos Creek-Existing Plan: Existing 3/5/2007 River = San Marcos Creek Reach = 1 RS = 1 Cross-Section #1 DIS (Dr. Chang's Cross SecUon #6.047) 370 r ,035 +035+ ,035 1 Legend WS PF#1 360 + ... 350 340 330 320 310+1~'~~rr"TT~~"rr""""~""rr,,, 800 900 1000 1100 1200 1300 1400 1500 Station (ft) Crit PF#1 -Ground • Bank Sta - - --- -- -- I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 3.1.2 CHANNEL PROFILE DE:de h:lreportsI175111361c1omrlclom,_01.doc w.o.1751·136 3/5120072:26 PM I I I I I I I I I I I I I I I I I I I g c o 350 340 ~ 330 Q) [jJ 320 o 1 in Horiz. = 100 ft 1 in Vert. = 5 ft 200 400 San Marcos Creek-Existing San Marcos Creek 1 600 Plan: Existing 3/5/2007 800 Main Channel Distance (ft) ,.-.' •..•. , ...... _ ..•.... _ ...... _ .. - ~ ........ ~ ....... ~ .. 1000 J 1 Legend WS PF#1 . __ .• __ .• +._ .• _--.• Crit PF#1 Ground ..... ~~ ... -~. 1200 I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 3.1.3 PRE-DEVELOPED CONDITION HEC-RAS REPORT DE:de h:lreporlsI175111361clomrlclomr_01.doc w.o.1751-136 3/5/20072:26 PM I I I I I I I I I I I I I I I I I I I SMC_Existing.rep HEC-RAS version 3.1.3 May 2005 u.s. Army corp of Engineers Hydrologic Engineering Center 609 second street Davis, california x X ~ xxxx xxxx XX X X X X X X X X X XXXXXXX xxxx X XXX X X X X X X X X X X X ~ xxxx PROJECT DATA project Title: San Marcos creek-Existing project File: SMC_Existing.prj Run Date and Time: 3/5/2007 5:13:36 PM project in English units project Description: San Marcos creek Floodplain Analysis PLAN DATA X X X X X X X X xxxx ~ X X X X X X X X X X X X xxxx X X xxxx X X xxxxx plan Title: Existing plan File: C:\Documents and settings\dedwards\Desktop\san Marcos creek rev-2-24-03\SMC_Existing.p03 Geometry Title: Existing Conditions Geometry File : C:\Documents and settings\dedwards\Desktop\san Marcos creek rev-2-24-03\SMC_Existing.g03 Flow Title : Existing Conditions Flow File : C:\Documents and Settings\dedwards\Desktop\san Marcos Creek rev-2-24-03\SMC_Existing.f02 plan summary Information: Number of: Cross sections 11 culverts = 0 Bridges = 1 Multiple openings = Inline Structures = Lateral Structures = computational Information Water surface calculation tolerance = critical depth calculation tolerance = Maximum number of iterations = Maximum difference tolerance Flow tolerance factor = computation options 0.01 0.01 20 0.3 0.001 critical depth computed only where necessary conveyance calculation Method: At breaks in n values only Friction slope Method: Average conveyance computational Flow Regime: Mixed Flow Page 1 o o o I I I I I I I I I I I I I I I I I I I SMC_Existing.rep FLOW DATA Flow Title: Existing conditions Flow File : C:\Documents and settings\dedwards\Desktop\san Marcos Creek rev-2-24-03\SMC_Existing.f02 Flow Data (cfs) River Reach San Marcos creek1 San Marcos creek1 Boundary Conditions River Downstream Reach San Marcos creek1 Normal S = 0.028 GEOMETRY DATA RS 11 7 Profi 1 e PF#l Geometry Title: Existing Conditions PF#l 13000 13000 upstream Critical Geometry File: C:\Documents and Settings\dedwards\Desktop\san Marcos creek rev-2-24-03\SMC_Existing.g03 CROSS SECTION RIVER: San Marcos creek REACH: 1 INPUT Description: Station Elevation Sta Elev 856 350 886.5 340 918.4 330 1000 324 1071. 5 328 1173 336 1210.5 346 Manning's n values Sta n val 856 .1 Data Sta 862 893.7 936.1 1013.7 1076.5 1179.8 Sta 899 Bank Sta: Left Right 899 1173 RS: 11 num= 31 Elev sta Elev 348 867.1 346 338 899 336 329 949.9 328 323.5 1030 324 329 1080.3 330 338 1187.3 340 num= 3 n val Sta n val .1 1173 .1 Lengths: Left Channel 219 219 CROSS SECTION OUTPUT profile #PF#l page 2 sta 872.7 905.9 964.1 1052.9 1083.7 1195 Right 219 Elev Sta 344 880.2 334 913.7 327 975.3 326 1062.2 332 1087 342 1202.4 coeff Contr. .1 Elev 342 332 326 327 334 344 Expan. .3 I I I I I I I I I I I I I I I I I I I SMCExisting.rep E.G. Elev (ft) 338.86 Element Left DB channel Right DB vel Head (ft) 0.46 Wt. n-Val. 0.100 0.100 0.100 W.S. Elev (ft) 338.41 Reach Len. (ft) 0.10 0.10 0.10 Crit W.S. (ft) 332.22 Flow Area (sq ft) 7.76 2392.65 9.88 E.G. slope (ft/ft) 0.007506 Area (sq ft) 7.76 2392.65 9.88 Q Total (cfs) 13000.00 Flow (cfs) 10.51 12975.61 13.88 TOp Width (ft) 289.09 TOP Width (ft) 6.77 274.00 8.33 vel Total (ft/s) 5.39 Avg. vel. (ft/s) 1. 35 5.42 1.40 Max chl Dpth (ft) 14.91 Hydr. Depth (ft) 1.15 8.73 1.19 Cony. Total (cfs) 150048.5 Cony. (cfs) 121.3 149767.0 160.2 Length wtd. (ft) 0.10 wetted Per. (ft) 7.19 276.74 8.67 Min ch El (ft) 323.50 shear (lb/sq ft) 0.51 4.05 0.53 Alpha 0.75 1.01 Stream Power (lb/ft s) 0.69 21. 97 Frctn Loss (ft) 0.00 Cum volume (acre-ft) 0.83 50.46 5.72 c & E. Loss (ft) 0.02 Cum SA (acres) 0.31 4.96 1. 51 warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. BRIDGE RIVER: San Marcos creek REACH: 1 RS: 10.5 INPUT Description: Distance from upstream XS = .1 Deck/Roadway Width = 200 weir coefficient 2.6 Upstream Deck/Roadway Coordinates num= 2 Sta Hi cord Lo cord Sta Hi cord Lo cord o 355 350 1202.4 349 344 Upstream Bridge Cross section Data station Elevation Data num= Sta Elev Sta Elev 856 350 862 348 886.5 340 893.7 338 918.4 330 936.1 329 1000 324 1013.7 323.5 31 Sta 867.1 899 949.9 1030 page Elev 346 336 328 324 3 Sta 872.7 905.9 964.1 1052.9 Elev 344 334 327 326 sta 880.2 913.7 975.3 1062.2 Elev 342 332 326 327 I I I I I I I I I I I I I I I I I I I SMC_Existing.rep 1071. 5 1173 1210.5 328 1076.5 336 1179.8 346 329 1080.3 330 1083.7 338 1187.3 340 1195 Manning's n values Sta n val 856 .1 num= Sta n val 899 .1 3 Sta 1173 Bank sta: Left Right 899 1173 coeff Cont r . . 1 Downstream Deck/Roadway coordinates num= 2 n val .1 Expan . .3 sta Hi cord Lo cord Sta Hi cord Lo cord o 355 350 1191.8 349 344 Downstream Bridge Station Elevation Cross section Data Sta Elev 799.3 350 831. 5 340 862.5 330 951.9 323 1078.5 324 1169.3 338 Manning's n values Data Sta 806.4 837.6 885.5 971 1140.6 1177 Sta n val Sta 799.3 .1 862.5 Bank Sta: Left Right 862.5 1140.6 num= Elev 348 338 330 322 330 340 29 Sta 812.5 843.9 899.3 1000 1147.6 1184.5 num= 3 n val Sta .1 1140.6 coeff Cont r . .1 Elev 346 336 329 321.5 332 342 n val .1 Expan. .3 sta 818.9 850.3 904 1033.1 1155.2 1191.8 332 1087 342 1202.4 Elev Sta 344 825.3 334 856.5 328 910.9 322 1064.7 334 1161. 7 344 Upstream Embankment side slope Downstream Embankment side slope Maximum allowable submergence for weir Elevation at which weir flow begins Energy head used in spillway design spillway height used in design = o horiz. to 1.0 vertical weir crest shape Number of Piers = 2 Pier Data Pier station upstream width 15 Downstream width 15 pi er Data pier station Upstream Width 15 Downstream Width 15 Upstream= num= 2 Elev width 326 15 num= 2 961.7 Elev 350 Elev width Elev 327 15 350 Upstream= 1059.7 num= 2 Elev width Elev 323 15 350 num= 2 Elev width Elev 329 15 350 Number of Bridge coefficient Sets = 1 = flow = = = = o horiz. to 1.0 vertical .95 = Broad crested Downstream= 957.4 Downstream= 1059.1 Page 4 334 344 Elev 342 332 327 323 336 I I I I I I I I I I I I I I I I I I I SMC_Existing.rep Low Flow Methods and Data Energy selected Low Flow Methods = High Flow Method Energy only Highest Energy Answer Additional Bridge Parameters Add Friction component to Momentum Do not add weight component to Momentum class B flow critical depth computations use critical inside the bridge at the upstream end criteria to check for pressure flow = upstream energy depth grade line BRIDGE OUTPUT profile #PF#l E.G. US. (ft) 338.86 Inside BR DS W.S. US. (ft) 338.41 337.32 Q Total (cfs) 13000.00 337.03 Q Bridge (cfs) 13000.00 329.27 Q wei r (cfs) 15.53 weir Sta Lft (ft) 4.20 weir Sta Rgt (ft) 3097.14 weir submerg 0.22 weir Max Depth (ft) 20586.61 Min El weir Flow (ft) 349.01 10.50 Min El Prs (ft) 345.67 354.71 Delta EG'(ft) 1.62 202231. 7 Delta WS (ft) 1.39 294.99 BR open Area (sq ft) 3874.77 0.06 BR open vel (ft/s) 6.47 0.02 coef of Q 2.25 Br sel Method Energy only 9.45 Element Inside BR US E.G. Elev (ft) 338.84 W.S. Elev (ft) 338.19 crit W.S. (ft) 332.98 Max chl Dpth (ft) 14.69 vel Total (ft/s) 6.47 Flow Area (sq ft) 2009.33 Froude # chl 0.40 specif Force (cu ft) 13292.96 Hydr Depth (ft) 7.80 W.P. Total (ft) 305.81 Conv. Total (cfs) 107030.2 Top width (ft) 257.47 Frctn Loss (ft) 1.41 C & E Loss (ft) 0.11 shear Total (lb/sq ft) 6.05 Power Total (lb/ft s) 39.15 warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION page 5 I I I I I I I I I I I I I I I I I I I RIVER: San Marcos creek REACH: 1 RS: 10 INPUT Description: Cross Section #10 station Elevation Data num= Sta Elev sta Elev 799.3 350 806.4 348 831.5 340 837.6 338 862.5 330 885.5 330 951.9 323 971 322 1078.5 324 1140.6 330 1169.3 338 1177 340 SMC_Existing.rep 29 Sta 812.5 843.9 899.3 1000 1147.6 1184.5 Elev 346 336 329 321. 5 332 342 Sta 818.9 850.3 904 1033.1 1155.2 1191. 8 Manning's n values num= 3 sta n val Sta 799.3 .1 862.5 Bank Sta: Left Right 862.5 1140.6 n val Sta .1 1140.6 n val .1 Lengths: Left Channel 198 120.5 Right 71.1 CROSS SECTION OUTPUT profile #PF#l E.G. Elev (ft) Right OB vel Head (ft) 0.100 W.S. Elev (ft) 71.10 crit W.S. (ft) 87.80 E.G. Slope (ft/ft) 87.80 Q Total (cfs) 142.94 TOP Width (ft) 24.98 vel Total (ft/s) 1.63 Max chl Dpth (ft) 3.52 Conv. Total (cfs) 2940.7 Length Wtd. (ft) 25.95 Mi n ch El (ft) 0.50 Alpha 0.81 Frctn Loss (ft) 5.46 C & E Loss (ft) 1.42 337.24 0.22 337.02 0.002363 13000.00 324.89 3.69 15.52 267441. 5 120.07 321. 50 1.04 0.43 0.03 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) TOp Width (ft) Avg. vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) wetted Pe r . (ft) shear (lb/sq ft) stream Power (lb/ft s) Cum volume (acre-ft) Cum SA (acres) Elev Sta 344 825.3 334 856.5 328 910.9 322 1064.7 334 1161. 7 344 coeff Contr. .1 Elev 342 332 327 323 336 Expan. .3 Left OB Channel 0.100 0.100 198.00 120.50 75.62 3357.09 75.62 3357.09 121.05 12736.01 21.81 278.10 1. 60 3.79 3.47 12.07 2490.3 262010.6 22.92 278.88 0.49 1. 78 0.78 6.74 0.60 37.78 0.23 3.72 Warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. page 6 I I I I I I I I I I I I I I I I I I I CROSS SECTION RIVER: San Marcos creek REACH: 1 RS: 9 INPUT Description: Cross section #9 Station Elevation Data num= Sta Elev Sta Elev 798.7 370 845.7 360 984.7 322 995.5 321 1039.9 323 1119 330 1222 338 1266.2 340 Manning's n values num= sta n Val Sta n val 798.7 .1 935.5 .1 Bank Sta: Left Right Lengths: 935.5 1119 SMC_Existing.rep 17 Sta 875.6 1000 1135.3 3 Sta 1119 Elev Sta 350 911 320.5 1022.2 332 1155.7 n val .1 Left Channel Right 75 81.4 35 CROSS SECTION OUTPUT Profile #PF#l E.G. Elev (ft) Right OB vel Head (ft) 0.100 W.S. Elev (ft) 35.00 crit W.S. (ft) 216.79 E.G. slope (ft/ft) 216.79 Q Total (cfs) 453.84 TOp Width (ft) 90.00 vel Total (ft/s) 2.09 Max chl Dpth (ft) 2.41 Cony. Total (cfs) 5776.8 Length wtd. (ft) 90.27 Min ch El (ft) 0.93 Alpha 1.94 Frctn Loss (ft) 5.21 C & E Loss (ft) 1. 33 CROSS SECTION RIVER: San Marcos creek 336.78 0.52 336.25 0.006172 13000.00 288.82 5.49 15.75 165472.9 79.39 320.50 1.12 0.46 0.04 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) TOp Width (ft) Avg. vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) wetted per. (ft) shear (lb/sq ft) Stream power (lb/ft s) Cum volume (acre-ft) Cum SA (acres) page 7 Elev Sta 340 935.5 321 1032.8 334 1207.1 coeff Contr. .1 Elev 330 322 336 Expan. .3 Left OB Channel 0.100 0.100 75.00 81.40 47.93 2103.54 47.93 2103.54 113.66 12432.50 15.32 183.50 2.37 5.91 3.13 11.46 1446.7 158249.4 16.55 184.65 1.12 4.39 2.65 25.94 0.32 30.22 0.15 3.08 I I SMC_Existing.rep REACH: 1 RS: 8 I INPUT Description: Cross section #8 Station Elevation Data num= 52 I Sta Elev Sta Elev sta Elev Sta Elev Sta Elev 785.4 370 838.2 360 868 350 891.2 340 926.6 330 992.3 321 1000 320.4 1010.8 321 1061.9 326 1159 330 1180.3 331 1187.9 332 1201 333 1221. 8 334 1224.7 335 I 1228.6 336 1234.9 337 1242.3 338 1248.2 339 1267.9 340 1274.7 339 1280.6 338 1286.7 337 1293.4 336 1297.8 335 1301. 9 334 1320.1 333 1356.6 332 1380.4 331 1385.9 330 1391.1 329 1431. 5 329 1435.3 330 1441.3 331 1447.5 332 1451. 3 333 1460.2 334 1464 335 1484.9 336 1486.2 337 I 1488.9 337 1490.1 336 1491.9 335 1493.5 334 1509.8 333 1519.5 334 1522 335 1524 336 1526.6 337 1530.8 338 1540.8 339 1544.3 340 I Manning's n values num= 3 Sta n val Sta n val Sta n val 785.4 .1 926.6 .1 1159 .1 I Bank Sta: Left Right Lengths: Left channel Right coeff Contr. Expan. 926.6 1159 111.43 120.3 120 .1 .3 Ineffective Flow num= 1 sta L Sta R Elev permanent I 1269.7 1544.3 F CROSS SECTION OUTPUT Profile #PF#l I E.G. Elev (ft) 336.27 Element Left OB Channel Right OB vel Head (ft) 0.40 Wt. n-val. 0.100 0.100 I 0.100 w.s. Elev (ft) 335.88 Reach Len. (ft) 111. 43 120.30 120.00 crit W. s. (ft) Flow Area (sq ft) 61.13 2359.80 I 246.95 E.G. slope (ft/ft) 0.005562 Area (sq ft) 61.13 2359.80 1065.28 Q Total (cfs) 13000.00 Flow (cfs) 135.45 12227.63 I 636.91 TOp Width (ft) 544.13 Top Width (ft) 20.80 232.40 290.93 vel Total (ft/s) 4.87 Avg. vel. (ft/s) 2.22 5.18 I 2.58 Max chl Dpth (ft) 15.48 Hydr. Depth (ft) 2.94 10.15 3.57 Cony. Total (cfs) 174319.1 Cony. (cfs) 1816.3 163962.3 I 8540.5 Length Wtd. (ft) 120.20 Wetted Per. (ft) 21.62 233.38 69.55 Min ch El (ft) 320.40 Shear (lb/sq ft) 0.98 3.51 I 1. 23 Alpha 1.08 Stream Power (lb/ft s) 2.18 18.19 3.18 Frctn Loss (ft) 0.75 Cum volume (acre-ft) 0.23 26.05 I 4.70 C & E LOSS (ft) 0.00 Cum SA (acres) 0.12 2.69 1.17 I page 8 I I I I I I I I I I I I I I I I I I I I SMC_Existing.rep warning: Divided flow computed for this cross-section. CROSS SECTION RIVER: san Marcos creek REACH: 1 RS: 7 INPUT Description: Cross-section #7 Station Elevation Data num= 43 Sta Elev Sta Elev Sta Elev Sta 690.83 380 700.99 379 708.72 378 715.2 373 759.89 360 834.47 335 912.77 734.77 375 746.46 374 751.91 786.63 370 810.33 365 825.61 860.33 345 877.96 340 896.84 976.57 321 991.2 320 1000 319.72 1008.84 328 1123.73 333 1283.74 338 1343.06 340 1040.6 326 1084.17 327 1117.93 1157.38 331 1181.4 332 1251.87 1329.86 337 1334.26 338 1338.83 1357.9 338 1360.31 339 1362.92 Manning's n values Sta n val Sta 690.83 .1 896.84 Bank Sta: Left Right 896.84 1040.6 num= 3 n val Sta .1 1040.6 n val .1 Lengths: Left Channel Right 73.52 100.15 106.36 CROSS SECTION OUTPUT Profile #PF#l E.G. Elev (ft) Right OB vel Head (ft) 0.100 W.s. Elev (ft) 106.36 Crit W.s. (ft) 1134.30 E.G. slope (ft/ft) 1134.30 Q Total (cfs) 3906.10 Top Width (ft) 246.56 vel Total (ft/s) 3.44 Max chl Dpth (ft) 4.60 Conv. Total (cfs) 46587.4 Length Wtd. Cft) 246.84 Mi n ch El (ft) 2.02 Alpha 6.95 Frctn LOSS (ft) 1.67 C & E LOSS (ft) 0.43 335.52 0.44 335.08 0.007030 13000.00 390.63 4.89 15.36 155049.0 101.05 319.72 1.19 0.81 0.02 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) TOp Width (ft) Avg. vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted per. (ft) shear (lb/sq ft) Stream Power (lb/ft s) Cum Volume (acre-ft) Cum SA (acres) page 9 Elev sta 377 725.82 372 774.04 355 844.96 330 940.14 320 1026-.08 329 1133.52 335 1326.22 337 1346.97 coeff Cont r . .1 Left OB 0.100 73.52 0.01 0.01 0.00 0.30 0.14 0.04 0.0 0.31 0.02 0.00 0.15 0.09 Elev 3.76 371 350 325 325 330 336 337 Expan. .3 Channel 0.100 100.15 1526.49 1526.49 9093.90 143.76 5.96 10.62 108461.6 145.99 4.59 27.34 20.69 2.17 I I I I I I I I I SMC_Existing.rep CROSS SECTION RIVER: San Marcos Creek REACH: 1 RS: 6 INPUT Description: Cross-section #6 Station Elevation Data num= 46 Sta Elev Sta Elev Sta 494.93 400 575.47 390 646.09 717.87 372 729.09 371 743.03 821.87 355 835.98 350 851.78 908.58 330 946.47 325 978.84 1008.06 319 1017.19 320 1033.51 1089.48 327 1099.19 327 1104.43 1136.33 331 1148.98 332 1155.99 1173.87 336 1217.5 336 1240.48 1258.48 337 1259.35 337 1283.41 1295 340 Manning's n values Sta n val Sta num= 3 n val Sta 494.93 .1 908.58 .1 1123.14 Elev Sta 380 691. 53 370 782.6 345 869.91 320 998.26 325 1050.43 328 1109.3 333 1161.47 336 1243.21 337 1289.96 n val .1 Bank Sta: Left Right 908.58 1123.14 Lengths: Left channel Right 84.54 84.95 104.32 I' CROSS SECTION OUTPUT Profi 1 e #PF#l I 'I I' I I I ,I I 'I E.G. Elev (ft) Right OB vel Head (ft) 0.100 W.S. Elev (ft) 104.32 crit W.S. (ft) 94.28 E.G. slope (ft/ft) 94.28 Q Total (cfs) 243.76 Top Width (ft) 38.68 vel Total (ft/s) 2.59 Max chl Dpth (ft) 2.44 Cony. Total (cfs) 2526.5 Length Wtd. (ft) 38.93 Mi n ch El (ft) 1.41 Alpha 3.64 Frctn Loss (ft) 0.17 C & E Loss (ft) 334.69 0.61 334.08 0.009309 13000.00 271. 72 6.09 15.48 134739.2 85.15 318.60 1.06 0.87 0.01 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. vel. (ft/s) Hydr. Depth (ft) Cony. (cfs) Wetted per. (ft) shear (lb/sq ft) Stream Power (lb/ft s) Cum volume (acre-ft) Cum SA (acres) Page 10 Elev Sta 374 703.41 365 805.03 340 885.95 319 1000 326 1068.05 329 1123.14 334 1165.61 336 1248.98 338 1292.73 coeff Cant r . .1 Left OB , 0.100 84.54 37.74 37.74 85.72 18.48 2.27 2.04 888.5 18.93 1.16 2.63 0.12 0.07 Elev 373 360 335 318.6 327 330 335 336 339 Expan. .3 Channel 0.100 84.95 2004.24 2004.24 12670.52 214.56 6.32 9.34 131324.3 216.45 5.38 34.02 16.63 1. 76 I I I I I' I I I I I I' I I I I' 'I I I I SMC_Existing.rep 0.09 CROSS SECTION RIVER: San Marcos creek REACH: 1 RS: 5 INPUT Description: Cross-Section #5 Station Elevation Data num= 40 Sta Elev Sta Elev Sta 556.43 400 621.34 390 661.36 712.94 365 731.07 360 764.68 834.73 340 854.24 335 873.72 994.55 319 1000 318.33 1010.91 1042.53 326 1049.61 327 1065.12 1077.18 329 1081.03 330 1097.16 1153.06 350 1164.99 351 1175.25 1247.54 350 1259.68 349 1274.6 Manning's n values Sta n val Sta num= 3 n val Sta 556.43 .1 873.72 .1 1081. 03 Elev Sta 380 678.15 355 791. 66 330 913.94 319 1018.9 327 1073.66 335 1111.87 352 1209.45 348 1305.63 n Val .1 Bank Sta: Left Right Lengths: Left Channel Right 873.72 1081.03 106.38 83.7 84.95 CROSS SECTION OUTPUT profile #PF#l E.G. Elev (ft) 333.81 Element Right OB vel Head (ft) 0.72 Wt. n-val. 0.100 W.S. Elev (ft) 333.10 Reach Len. (ft) 84.95 crit W.S. (ft) Flow Area (sq ft) 15.46 E.G. slope (ft/ft) 0.011158 Area (sq ft) 15.46 Q Total (cfs) 13000.00 ,Flow (cfs) 31. 50 TOp width (ft) 229.36 TOp Width (ft) 9.99 vel Total (ft/s) 6.73 Avg. vel. (ft/s) 2.04 Max chl Dpth (ft) 14.77 Hydr. Depth (ft) 1. 55 Conv. Total (cfs) 123071.4 Conv. (cfs) 298.2 Length Wtd. (ft) 83.74 Wetted per. (ft) 10.46 Min ch El 1.03 (ft) 318.33 Shear (lb/sq ft) Elev Sta 375 695.92 350 819.29 325 989.76 320 1036.74 327 1075.63 340 1129.67 352 1225.19 347.21 1332.66 Elev 370 345 320 325 328 345 351 354.3 coeff Contr. Expan. .1 .3 Left OB channel 0.100 0.100 106.38 83.70 18.67 1896.62 18.67 1896.62 38.39 12930.11 12.06 207.31 2.06 6.82 1. 55 9.15 363.5 122409.8 12.45 209.52 1.04 6.31 Alpha 1.02 Stream Power (lb/ft s) 2.15 42.99 2.10 Frctn Loss (ft) 1.04 Cum volume (acre-ft) 0.06 12.83 0.04 C & E Loss (ft) 0.01 Cum SA (acres) 0.04 1.35 0.03 Page 11 I I I I I I I I I I I' I I I ,I I I I I SMC_Ex;st;ng.rep warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: San Marcos creek REACH: 1 RS: 4 INPUT Description: cross-Section #4 station Elevation Data num= 41 Sta E1ev Sta E1ev Sta 678.28 400 716.25 390 735.55 782.31 370 801.95 365 816.66 859.68 345 874.58 340 895.96 972.9 320 983.33 319 994.86 1011.51 319 1033.43 320 1047.25 1070.6 326 1075.28 329 1098.95 1129.34 340 1144.92 345 1160.54 1227.4 362 1263.88 362 1282.93 1358.23 355.7 Manning's n values Sta n val sta num= 3 n val Sta 678.28 .1 908.77 .1 1108.25 E1ev Sta 385 753.13 360 831. 54 335 908.77 318 1000 320 1060.67 329 1108.25 350 1182.45 360 1322.33 n val .1 Bank Sta: Left Right 908.77 1108.25 Lengths: Left Channel 77.73 90.76 Right 77 .43 CROSS SECTION OUTPUT profile #PF#l E.G. E1ev (ft) 332.77 'Element Right OB Vel Head (ft) 0.84 Wt. n-va1. 0.100 w.s. E1ev (ft) 331. 92 Reach Len. (ft) 77.43 Crit W.S. (ft) Flow Area (sq ft) 4.25 E.G. slope (ft/ft) 0.013805 Area (sq ft) 4.25 Q Total (cfs) 13000.00 Flow (cfs) 6.82 TOp width (ft) 208.82 TOP width (ft) 4.42 vel Total (ft/s) 7.34 Avg. vel. (ft/s) 1.61 Max ch1 Dpth (ft) 14.48 Hydr. Depth (ft) 0.96 Cony. Total (cfs) 110643.1 Cony. (cfs) 58.0 Length Wtd. (ft) 90.75 wetted per. (ft) 4.82 Min ch E1 (ft) 317.44 shear (lb/sq ft) 0.76 E1ev Sta 380 767.74 355 843.82 330 940.33 317.44 1005.14 320 1069.44 330 1119.74 355 1209.64 356 1348.43 coeff Contr. .1 Left OB 0.100 77.73 4.74 4.74 7.68 4.93 1.62 0.96 65.4 5.29 0.77 Alpha 1.01 stream power (lb/ft s) 1.25 1.22 Page 12 E1ev 375 350 325 318 325 335 360 355 Expan. .3 channel 0.100 90.76 1761. 91 1761. 91 12985.50 199.48 7.37 8.83 110519.7 203.14 7.48 55.09 I Ii I I I I' I I I I I I' I I I I I I I Frctn LoSS (ft) 0.02 C & E Loss (ft) 0.01 SMC_Existing.rep 1.23 Cum volume (acre-ft) 0.01 Cum SA (acres) 0.04 0.02 9.31 0.96 warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: San Marcos creek REACH: 1 RS: 3 INPUT Description: Cross-section #3 station Elevation Data Sta Elev Sta 756.56 400 782 834.12 37.5 845.86 891. 99 350 899.97 949.34 325 968.54 998.51 316 1000 1038.01 319 1054.64 1081.19 320 1090.94 1136.48 335 1151. 92 1244.92 366 1265.74 1322.77 366 1330.54 1400.02 358 1406.82 Manning's n values Sta n val Sta 756.56 .1 929.59 Bank Sta: Left Right 929.59 1096.42 num= 55 Elev Sta 395 797.74 370 861. 01 345 908.29 320 981.81 315.9 1001. 49 320 1063.98 325 1096.42 340 1184.21 367 1287.71 365 1337.32 357 1410.77 num= 3 n val Sta .1 1096.42 Elev Sta 390 809.19 365 871.59 340 917.99 319 988.18 316 1013.47 320 1074.56 330 1104.95 350 1216.77 368 1290.89 364 1382.59 357 1425.17 n val .1 Lengths: Left Channel Right 62.17 102.86 114.21 CROSS SECTION OUTPUT Profile #PF#l E.G. Elev (ft) Right OB vel Head (ft) 0.100 w.s. Elev (ft) 114.21 Crit W.S. (ft) 0.37 E.G. slope (ft/ft) 0.37 Q Total (cfs) 0.26 Top Width (ft) 1.26 vel Total (ft/s) 0.71 Max chl Dpth (ft) 0.29 Cony. Total (cfs) 2.3 331. 53 0.94 330.59 0.013230 13000.00 169.45 7.78 14.69 113020.2 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) TOp Width (ft) Avg. Vel. (ft/s) Hydr. Depth (ft) Cony. (cfs) page 13 Elev Sta Elev 385 820.36 380 360 882.06 355 335 929.59 330 318 991.86 317 317 1021. 52 318 319 1076.35 319 334 1124.08 334 360 1236.15 365 368 1309.25 367 360 1389.89 359 357 1433.14 358.6 coeff Contr. Expan. '.1 .3 Left OB Channel 0.100 0.100 62.17 102.86 0.40 1670.24 0.40 1670.24 0.29 12999.45 1. 37 166.83 0.71 7.78 0.29 10.01 2.5 113015.4 I II I I I I I I' I I I I I' :? I' '-' I I SMC_Existing.rep Length wtd. (ft) 102.86 wetted per. (ft) 1.49 171.88 1. 39 Min ch E1 (ft) 315.90 shear (lb/sq ft) 0.22 8.03 0.22 Alpha 1.00 Stream Power (lb/ft s) 0.16 62.47 0.16 Frctn Loss (ft) 1.72 Cum volume (acre-ft) 0.03 5.73 0.01 C & E Loss (ft) 0.05 Cum SA (acres) 0.02 0.58 0.01 warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: San Marcos creek REACH: 1 RS: 2 INPUT Description: Cross-Section #2 station Elevation Data num= 44 Sta E1ev Sta E1ev Sta 817.95 390 835.8 385 848.86 886.76 365 897.43 360 907.12 937.72 340 945.29 335 955.45 992.43 316 995.62 315 1000 1022.62 317 1040.86 317 1070.99 1095.8 330 1112.35 330 1124.85 1145.49 330 1163.01 335 1179.36 1223 355 1240.82 360 1256.16 1427.66 360 1472.02 358 1477.48 Manning's n Values Sta n val Sta num= 3 n val Sta 817.95 .1 955.45 .1 1095.8 Elev Sta 380 861.86 355 915.7 330 964.03 314.34 1004.39 317 1079.24 329 1132.22 340 1191. 6 365 1318.92 357.6 1501. 06 n val .1 Bank Sta: Left Right 955.45 1095.8 Lengths: Left Channel Right 181.76 92.2 63.34 CROSS SECTION OUTPUT profile #PF#l E.G. E1ev (ft) Right OB vel Head (ft) w.s. E1ev (ft) 63.34 crit W.S. (ft) E.G. slope (ft/ft) Q Total (cfs) TOp Width (ft) 329.76 1.48 328.27 0.021693 13000.00 135.19 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) TOp width (ft) page 14 E1ev Sta 375 874.73 350 925.43 325 974.02 315 1011. 84 320 1089.41 328.33 1142.44 345 1208 369.8 1372.13 358.6 coeff Contr. .1 E1ev 370 345 320 316 325 329 350 365 Expan. .3 Left OB Channel 0.100 181.76 92.20 1329.82 1329.82 13000.00 135.19 I I I I I I I: I I I' I I' I I I I SMC_Existing.rep vel Total (ft/s) 9.78 Avg. vel. (ft/s) 9.78 Max chl Dpth (ft) 13.93 Hydr. Depth (ft) 9.84 Cony. Total (cfs) 88263.4 Cony. (cfs) 88263.4 Length wtd. (ft) 92.38 Wetted Per. (ft) 140.87 Min ch El (ft) 314.34 shear (lb/sq ft) 12.79 Alpha 1.00 Stream Power (lb/ft s) 124.98 Frctn Loss (ft) 1.16 Cum Volume (acre-ft) 0.03 2.19 0.01 C & E Loss (ft) 0.31 Cum SA (acres) 0.02 0.22 0.01 warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: san Marcos Creek REACH: 1 RS: 1 INPUT Description: cross-section #1 D/S station Elevation (Dr. chang's Cross section #6.047) Data Sta Elev Sta 879.61 353.9 893.38 948.88 330 957.68 985.29 313 989.11 1030.85 314 1034.87 1060.24 327 1131. 57 1170.78 345 1186.7 1269.54 369 1349.66 Manning's n values Sta n val Sta 879.61 .035 968.62 Bank Sta: Left Right 968.62 1042.44 num= 35 Elev Sta 350 911. 57 325 968.62 312 1000 315 1042.44 327 1135.93 350 1204.59 365 1408.31 num= 3 n val Sta .035 1042.44 Elev Sta 345 924.79 320 974.88 311. 76 1010.89 320 1054.34 330 1140.53 355 1223.18 360 1458.18 n val .035 Lengths: Left Channel Right o o 0 CROSS SECTION OUTPUT Profile #PF#l E.G. Elev (ft) Right OB vel Head (ft) 0.035 328.29 4.58 Element Wt. n-val. page 15 Elev Sta 340 937.35 315 980.16 312 1025.07 325 1056.34 335 1150.46 360 1239.57 357.21 1480.39 coeff Contr. .1 Left OB 0.035 Elev 335 314 313 326 340 365 358.65 Expan. .3 Channel 0.035 I I I I I I I, I I I' I II 'I I I I I- I I W.S. Elev (ft) SMC_Existing.rep 323.71 Reach Len. (ft) crit w.S. (ft) 323.71 Flow Area (sq ft) 15.05 742.26 16.37 E.G. slope (ft/ft) 0.008168 Area (sq ft) 15.05 742.26 16.37 Q Total (cfs) 13000.00 Flow (cfs) 81.80 12828.42 89.78 Top width (ft) 90.76 8.83 Top Width (ft) 8.11 73.82 vel Total (ft/s) 16.80 5.49 Avg. vel. (ft/s) 5.44 17.28 Max chl Dpth (ft) 11.95 Hydr. Depth (ft) 1.85 10.06 1.85 conv. Total (cfs) 143845.6 Conv. (cfs) 905.1 141947.0 993.5 Length wtd. (ft) Wetted per. (ft) 8.92 77 .64 9.57 Min ch El (ft) 311. 76 shear (lb/sq ft) 0.86 4.87 0.87 Alpha 1.05 Stream Power (lb/ft s) 4.67 84.25 4.78 Frctn Loss (ft) Cum volume (acre-ft) C & E Loss (ft) Cum SA (acres) warning: slope too steep for slope area to converge during supercritical flow calculations (normal depth is below critical depth). water surface set to critical depth. SUMMARY OF MANNING'S N VALUES River:san Marcos creek Reach River Sta. n1 n2 n3 1 11 .1 .1 .1 1 10.5 Bridge 1 10 .1 .1 .1 1 9 .1 .1 .1 1 8 .1 .1 .1 1 7 .1 .1 .1 1 6 .1 .1 .1 1 5 .1 .1 .1 1 4 .1 .1 .1 1 3 .1 .1 .1 1 2 .1 .1 .1 1 1 .035 .035 .035 SUMMARY OF REACH LENGTHS River: San Marcos creek Reach River Sta. Left Channel Right Page 16 I I I I, I I I I I I I I I~ I I I I I I' SMC_Existing.rep 1 11 219 219 219 1 10.5 Bridge 1 10 198 120.5 71.1 1 9 75 81.4 35 1 8 111.43 120.3 120 1 7 73.52 100.15 106.36 1 6 84.54 84.95 104.32 1 5 106.38 83.7 84.95 1 4 77.73 90.76 77 .43 1 3 62.17 102.86 114.21 1 2 181. 76 92.2 63.34 1 1 0 0 0 SUMMARY OF CONTRACTION AND EXPANSION COEFFICIENTS River: San Marcos creek Reach River Sta. Contr. Expan. 1 11 .1 .3 1 10.5 Bridge 1 10 .1 .3 1 9 .1 .3 1 8 .1 .3 1 7 .1 .3 1 6 .1 .3 1 5 .1 .3 1 4 .1 .3 1 3 .1 .3 1 2 .1 .3 1 1 .1 .3 profile output Table -standard Table 1 Reach River sta profile Q Total Mi n ch El w.s. Elev crit W.S. E.G. Elev E.G. slope vel chnl Flow Area TOP width Froude # chl (cfs) (ft) (ft) (ft) (ft) (ft/ft) (ft/s) (sq ft) (ft) 1 11 PF#l 13000.00 323.50 338.41 332.22 338.86 0.007506 5.42 2410.28 289.09 0.32 1 10.5 Bri dge 1 10 PF#l 13000.00 321. 50 337.02 337.24 0.002363 3.79 3520.51 324.89 0.19 1 9 PF#l 13000.00 320.50 336.25 336.78 0.006172 5.91 2368.25 288.82 0.31 1 8 PF#l 13000.00 320.40 335.88 336.27 0.005562 5.18 2667.88 544.13 0.29 1 7 PF#l 13000.00 3l9.72 335.08 335.52 0.007030 5.96 2660.80 390.63 0.32 1 6 PF#l 13000.00 318.60 334.08 334.69 0.009309 6.32 2136.27 271. 72 0.36 1 5 PF#l 13000.00 318.33 333.10 333.81 0.011158 6.82 1930.75 229.36 0.40 1 4 PF#l 13000.00 317.44 331. 92 332.77 0.013805 7.37 1770.89 208.82 0.44 page 17 I I I I I I I I I I I I, 'I I I I I I: I 1 1 1 3 331. 53 0.013230 2 329.76 0.021693 1 328.29 0.008168 SMC_Existing.rep PF#l 13000.00 7.78 1671.01 PF#l 13000.00 9.78 1329.82 PF#l 13000.00 17.28 773.68 page 18 315.90 330.59 169.45 0.43 314.34 328.27 135.19 0.55 311.76 323.71 323.71 90.76 0.96 I 1 :1:' I 1 I 1 ' I" I' .' I' I I' I I I ' I I ,I I . , . . , , , . " • 4 .' . , .',', .' . ,,' .. . . '. .' -, ., . , .' .,'.' 'IV , . . -', . , , . : " .' , " . '.- .' . . "-, '.' . -, . '.' "' .. ':,', ~ '. " . ". , "'.:.' . '., . . '. . . ". , , ' .... .. '. :.' " ,' ... .' . \' . '. ,:-... '. ... .. " . ", " " '. . . . . • '. • • < .: .- . '. . .', . . . . -' ',', , ' , , . . -. , , " :' : ';. . -, , , .: ' , , '. T' I.,. ._ . . .. , '. : '. . '. . ,'.: . " :. '. . .' -, . . . , -, , -, - " '-, . . . . ... . , '. ' ' ... , , ,'.. , -, , " , I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 4 DEVELOPED CONDITIONS HEC-RAS RESULTS DE:de h:lreportsI175111361clomrlclom,-01.doc w.o.17510136 3/5/20072:26 PM I I. I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 4.1 DEVELOPED SUMMARY TABLE DE:de h:lreportsI17511136Ic1omrlclom,-01.doc w.o.1751-136 3/5120072:26 PM - - -- ----- ---- - - - - - HEC-RAS Plan: Dev-Normal River: San Marcos Creek Reach: 1 Profile: PF#1 ~0;t~~~~ht:;3 ~ tg[;e~;~~:t=-~,:;;.~'p~afi!~~~? '{(Q~T,bfa):;:Z ;',(Mi~~Qt1;1;f;;; ~:~!\&'i$:;::~!~~~3 ;/9~1~W!;J3~=,; ~,~~§S~i~T pc~%:~sl§pi:a;: ,:~y~(rQJ!Q(~;K:i C:E!t:i~:,6;~4~;t:: ~{J:<t)~w,iBih~,~' ::~Ei:b~~~i~¥g;t: ;~i~{:?!;;iJ~~,i~:; ;A~,~X'~ ;':'r?11;:;~~;>'.':;';~~:~,: ';'~:f,,(~f~F,:,r',~; /;:::':'(mi~~,'!;::; :Y:~ ~f!){;c:':'; ,~~:t{i(ft)' " '~,; :,~':~~;~@'.I,~L': i.-; ~ :'tttlnk:' :~'i f~'~~,rfU~)~7<i;: ;z; H~MtJij{~~, :~;'::"'~:1(f1:V':~;:', ~ ,;'~: ~ ;:,;:; ,~:, ~:,', ", ~{~ ~;b:~:;t:E~ ;1;1:;,,;~':::'{;e-; 'F,(ft#.~;':':':-',::) 13000,00 323,50 338.41 332,22 338,87 0,007496 5.42 2411.34 289.12 0,32 ':f,~~ ,:i.;{'i'J ~j'Q~5;:;~,:"c::; ':) ~"::'; ': :':'~ , ' Bridge .1::'~';:':~;:.~'~:~:1~6:~::,~",~~,;;':P.E#i::';';:;-:: 13000.00 321,50 337.03 337.25 0.002359 3.79 3522.49 324,93 0.19 'F: ~~":,~~:~;~ ,iF, ':;,::: ><: :,PFtt1:' , ' 13000.00 320.50 336.26 336.78 0.006156 5.91 2370.47 288.90 0.31 1:>" ::~::;~~:,1,~>',:<:,,~:,"',RF#1 ",":,' 13000.00 320.40 335.89 336.28 0.005544 5.18 2670.78 544.46 0.29 1;:~ ,1 '-,":~f,'::'<, ;'l~:i_';', " PF#1 ',' 13000.00 319,72 335.08 335.53 0.007115 5.99 2661.59 398.53 0.32 1':: \;;,,': ;~·r:::-' ,,:', PF#1 13000.00 318.60 334.08 334.69 0,009309 6.32 2136.27 271.72 0.36 1: ,C ':::F<~""r',' " PF#1 ,,,,,' 13000.00 318.33 333.10 333.81 0,011158 6.82 1930.75 229.36 0.40 1, .';:;;;~~: :4:7:"".' ,i', PF#1 ',:" 13000.00 317.44 331.92 332.77 0.013805 7.37 1770.89 208.82 0.44 '1:, ';;,' "d';} '3!:,; .. ,:,,~:, PF#1 ." 13000.00 315.90 330.59 331.53 0,013230 7.78 1671.01 169.45 0.43 f, <, ',:: :' 2)"',' , PF#1, ," ::\ 13000.00 314.34 328.27 329.76 0.021693 9.78 1329.82 135.19 0,55 1:' ,,';:'::', 1~:' ':.' ;,' ·.'RF#1 13000.00 311.76 323.71 323.71 328.29 0.008168 17.28 773.68 90.76 0.96 - I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 4.1.1 CHANNEL CROSS SECTIONS DE:de h:lrepoJ1s1175111361c1omrlclom,_01.doc w.o.1751-136 315120072:26 PM -- g c 0 ~ > OJ ill g c .2 10 > OJ ill -- -- - --- San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 River = San Marcos Creek Reach = 1 RS = 11 350 .1 )i( .1 )i( .11 345 340 335 -" +. 330 325 320 I I I I I I I I I 850 900 950 1000 1050 1100 1150 1200 1250 Station (ft) Legend WS PF#1 .+. Crit PF#1 Ground • Bank Sta San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 River = San Marcos Creek Reach = 1 RS = 10.5 BR r-.1 + .1 )~.14 355 Legend 350--1 it:,::;;'_:c.~:,.,::i{ -: :'.,-. ' WS PF#1 -... + ~. Crit PF#1 345 '-. ~ • Ground -h • 340 ' .. Bank Sta ".- ~, 335 ~ "' " 330 " .~-~ .; Po: l,' 325--1 " 1-: ;~l 320 I i i I i i I i i I i i I i i I 700 800 900 1000 1100 1200 Station (ft) g c 0 ~ > OJ ill g c 0 "" ro > OJ ill ---- --- San Marcos Creek-Developed Plan: Dev-Normal-Depth River = San Marcos Creek Reach = 1 RS = 10.5 L.1 + .1 +.11 355-1 350 3/5/2007 BR Legend WS PF#1 - ---+--. 345 \i ~l .,') '.' 335 ,,, , '~~I' """"""+" I,: 330 325 320 I I I I I I I I I 850 900 950 1000 1050 1100 1150 1200 1250 Station (ft) Crit PF#1 Ground 1# Bank Sta San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 River = San Marcos Creek Reach = 1 RS = 10 Cross Section #10 350 345 340 335 330 325 320 700 800 .1 )i( .1 )i( .11 900 1000 1100 Station (ft) Legend WS PF#1 1200 Ground • Bank Sta - -- g c: 0 "" ro > Q) ill g c: 0 ~ > ~ w ---- --- - --- -- - -- San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 River = San Marcos Creek Reach = 1 RS = 9 Cross section #9 370 .1-+-.1 + .1--1 360 350 340 330 320 Ii' "Fi'" 700 800 900 1000 Station (ft) 1100 1200 1300 Legend WS PF#1 Ground • Bank Sta San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 River = San Marcos Creek Reach = 1 RS = 7 Cross-Section #7 380 +-.1-+ .1 )1 370 360 350 340 330 320 310 I I I I I I I I I 600 700 800 900 1000 1100 1200 1300 1400 Station (ft) Legend WS PF#1 Ground • Bank Sta g c: o ~ Q) ill San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 River = San Marcos Creek Reach = 1 RS = 8 Cross section #8 .1-+-.1~.1 )1 600 800 1000 1200 1400 Station (ft) 1600 Legend WS PF#1 Ground ... Ineff • Bank Sta San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 River = San Marcos Creek Reach = 1 RS = 6 Cross-Section #6 I" .1 )1<------.1 )1" .1 --I 400 Legend WS PF#1 380 g 360 Ground • Bank Sta c: o ~ ~ 340 w 320 300+I-.o-r.-ro-r.-..-r.-r.-,,-..-.. -..-,,-. 400 600 800 1000 1200 1400 Station (ft) - - - g c 0 ~ > (I) iIi g c 0 "" co > (I) iIi ---- - ------- - -- - San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 River = San Marcos Creek Reach = 1 RS = 5 Cross-Section #5 400 380 360 340 320 300 400 ~.1----+-.1 + .1----1 600 800 1000 1200 Station (ft) 1400 Legend WS PF#1 Ground • Bank Sta San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 River = San Marcos Creek Reach = 1 RS = 3 Cross-Section #3 400 .1 + .1--+--.1 )1 380 360 340 320 300 I I I I I I I I I 700 800 900 1000 1100 1200 1300 1400 1500 Station (ft) Legend WS PF#1 Ground • Bank Sta San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 River = San Marcos Creek Reach = 1 RS = 4 Cross-Section #4 J--..-.1 )1< .1---4 .1 400 Legend WS PF#1 380 g 360 Ground • Bank Sta c o ~ ill 340 g c o 1 iIi 320 300 I I I I I I I I I 600 700 800 900 1000 1100 1200 1300 1400 Station (ft) San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 River = San Marcos Creek Reach = 1 RS = 2 Cross-Section #2 L.1-----.L.1 )1< .1 ,,1 400-1 ~ 380 300 I I I I I I I I I 800 900 1000 1100 1200 1300 1400 1500 1600 Station (ft) Legend WS PF#1 Ground • Bank Sta - -- g c o ~ (]) [ij - ----- -- San Marcos Creek-Developed Plan: Dev-Normal-Depth 3/5/2007 RIver = San Mareos Creek Reach = 1 RS = 1 Cross·Section #1 DIS (Dr. Chang's Cross Section #6.047) 370 ~ .035 +.035+ .035 )1 360 350 340 330 320 310 I I I I I I 800 900 1000 1100 1200 1300 1400 1500 Station (ft) Legend WS PF#1 +. '- Crit PF#1 Ground • Bank Sta --- ---- -- I I I I I I' I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 4.1.2 CHANNEL PROFILE DE:de h:lreportsI175111361clomrldom,-01.doc w,o.1751·136 315/20072:26 PM I 1 1 ,I 1 1 1 I I I I I I I I I I I I I San Marcos Creek-Developed Pf~n: Dev-Normal-Depth 3/5/2007 I< San Marcos Creek 1 l )1 g c o l ill 350 340 330 320 o 1 in Horiz. '= 100 ft 1 in Vert. = 5 ft ..... -."'"'" ~.,~ ~ .... ", ..... ' ........................... ~ 200 400 600 800 1000 Main Channel Distance (ft) Legend WS PF#1 ............ + .... _ ...... Crit PF#1 Ground 1200 I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 4.1.3 DEVELOPED CONDITION HEC-RAS REPORT DE:de h:lreportsI175111361c!omi\dom,_01.dOC w.o.1751.136 315120072:26 PM I I I " .... "'. I I I I I I I I I I I I I I I I .'SMc_Developed.rep HEC-RASVersion 3.1.3 May 2005 u.s. Army corp of Engineers Hydrologic Engineering Center 609.second Street Davis, california x X ~ XXXX XXXX XX X X X X X X X X X XXXXXXX XXXX X XXX X X X X X X X X X X X ~ XXXX PROJECT DATA project Title: San Marcos creek-Developed project File: SMC_Developed.prj Run Date and Time: 3/5/2007 5:04:04 PM project in English units project Description: San Marcos creek Floodplain Analysis PLAN DATA plan Title: Dev-Normal-Depth X X X X X X X X XXXX ~ X X X X X X X X X X X X XXXX X X XXXX X X XXXXX plan File: C:\Documents and settings\dedwards\Desktop\san Marcos creek rev-2-24-03\sMC_Developed.p04 Geometry Title: Developed conditions Geometry File: C:\Documents and settings\dedwards\Desktop\san Marcos creek rev-2-24-03\sMC_Developed.g03 Flow Title : Dev-Normal Depth Flow File : C:\Documents and settings\dedwards\Desktop\san Marcos creek rev-2-24-03\SMC_Developed.f03 plan Summary Information: Number of: Cross sections = 11 culverts = 0 Bridges 1 MUltiple openings = Inline Structures = Lateral Structures = computational Information water surface calculation tolerance = critical depth calculation tolerance = Maximum number of iterations 0.01 0.01 20 0.3 Maximum difference tolerance Flow tolerance factor = = 0.001 computation options critical depth computed only where necessary Conveyance calculation Method: At breaks in n values only Friction slope Method: Average conveyance Computational Flow Regime: Mixed Flow Page 1 o o o I I I I I I I I I I I I I I I I I I I SMC_Developed.rep FLOW DATA Flow Title: Dev-Normal Depth Flow File : C:\Documents and settings\dedwards\Desktop\san Marcos creek rev-2-24-03\sMC_Developed.f03 Flow Data (cfs) River Reach San Marcos creek1 San Marcos creek1 Boundary conditions River Downstream Reach San Marcos creek1 Normal S = 0.028 GEOMETRY DATA RS 11 7 Profile PF#l PF#l 13000 13000 upstream Critical Geometry Title: Developed conditions Geometry File: C:\Documents and settings\dedwards\Desktop\san Marcos creek rev-2-24-03\SMC_Developed.g03 CROSS SECTION RIVER: San Marcos creek REACH: 1 INPUT Description: station Elevation Sta Elev 856 350 886.5 340 918.4 330 1000 324 1071. 5 328 1173 336 1210.5 346 Manning's n values Sta n val 856 .1 Data Sta 862 893.7 936.1 1013.7 1076.5 1179.8 Sta 899 Bank Sta: Left Right 899 1173 RS: 11 num= 31 Elev Sta Elev 348 867.1 346 338 899 336 329 949.9 328 323.5 1030 324 329 1080.3 330 338 1187.3 340 num= 3 n val sta n val .1 1173 .1 Lengths: Left Channel 219 219 CROSS SECTION OUTPUT profile #PF#l page 2 sta 872.7 905.9 964.1 1052.9 1083.7 1195 Right 219 Elev Sta 344 880.2 334 913.7 327 975.3 326 1062.2 332 1087 342 1202.4 coeff Cont r . .1 Elev 342 332 326 327 334 344 Expan. .3 I I I I I I I I I I I I I I I I I I I SMC_Developed.rep E.G. Elev (ft) 338.87 Element Left DB channel Right DB Vel Head (ft) 0.46 wt. n-val. 0.100 0.100 0.100 W.S. Elev (ft) 338.41 Reach Len. (ft) 0.10 0.10 0.10 crit W.S. (ft) 332.22 Flow Area (sq ft) 7.78 2393.65 9.91 E.G. slope (ft/ft) 0.007496 Area (sq ft) 7.78 2393.65 9.91 Q Total (cfs) 13000.00 Flow (cfs) 10.54 12975.53 13.93 TOp Width (ft) 289.12 TOp width (ft) 6.78 274.00 8.34 vel Total (ft/s) 5.39 Avg. vel. (ft/s) 1. 35 5.42 1.41 Max chl Dpth (ft) 14.91 Hydr. Depth (ft) 1.15 8.74 1.19 Cony. Total (cfs) 150154.4 Cony. (cfs) 121.8 149871. 8 160.9 Length wtd. (ft) 0.10 wetted per. (ft) 7.20 276.74 8.68 Min ch El (ft) 323.50 shear (lb/sq ft) 0.51 4.05 0.53 Alpha 1.01 Stream power (lb/ft s) 0.69 21. 94 0.75 Frctn Loss (ft) 0.00 Cum volume (acre-ft) 0.83 50.48 5.73 C & E Loss (ft) 0.02 Cum SA (acres) 0.31 4.96 1. 53 warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. BRIDGE RIVER: San Marcos creek REACH: 1 RS: 10.5 INPUT Description: Distance from upstream XS = .1 Deck/Roadway width = 200 weir coefficient = 2.6 Upstream Deck/Roadway coordinates num= 2 Sta Hi cord Lo cord Sta Hi cord Lo cord o 355 350 1202.4 349 344 Upstream Bridge Cross section Data Station Elevation Data num= 31 Sta Elev Sta Elev Sta Elev 856 350 862 348 867.1 346 886.5 340 893.7 338 899 336 918.4 330 936.1 329 949.9 328 1000 324 1013.7 323.5 1030 324 Page 3 Sta Elev Sta Elev 872.7 344 880.2 342 905.9 334 913.7 332 964.1 327 975.3 326 1052.9 326 1062.2 327 I I I I I I I I I I I I I I I I I I I SMc_Developed.rep 1071. 5 328 1076.5 329 1080.3 330 1173 336 1179.8 338 1187.3 340 1210.5 346 Manning's n values num= 3 Sta n val Sta n val Sta n val 856 .1 899 .1 1173 .1 Bank Sta: Left Right coeff Contr. Expan . 899 1173 . 1 .3 Downstream Deck/Roadway coordinates num= 2 Sta Hi cord Lo cord Sta Hi cord Lo cord 0 355 350 1191. 8 349 344 Downstream Bridge cross Section Data station Elevation Data num= 29 Sta Elev Sta Elev Sta Elev 799.3 350 806.4 348 812.5 346 831. 5 340 837.6 338 843.9 336 862.5 330 885.5 330 899.3 329 951.9 323 971 322 1000 321. 5 1078.5 324 1140.6 330 1147.6 332 1169.3 338 1177 340 1184.5 342 Manning's n values num= 3 Sta n val Sta n val Sta n val 799.3 .1 862.5 .1 1140.6 .1 Bank Sta: Left Right coeff Contr. Expan. 862.5 1140.6 .1 .3 = flow = = = = 1083.7 332 1087 1195 342 1202.4 Sta Elev Sta 818.9 344 825.3 850.3 334 856.5 904 328 910.9 1033.1 322 1064.7 1155.2 334 1161. 7 1191. 8 344 o horiz. to 1.0 vertical o horiz. to 1.0 vertical .95 Upstream Embankment side slope Downstream Embankment side slope Maximum allowable submergence for weir Elevation at which weir flow begins Energy head used in spillway design spillway height used in design weir crest shape = Broad crested Number of Piers = 2 pier Data pier Station upstream= 961.7 Downstream= 957.4 Upstream num= 2 width Elev Width Elev 15 326 15 350 Downstream num= 2 width Elev width Elev 15 327 15 350 Pier Data pier station Upstream= 1059.7 Downstream= 1059.1 Upstream num= 2 width Elev width Elev 15 323 15 350 Downstream num= 2 width Elev width Elev 15 329 15 350 Number of Bridge coefficient Sets = 1 page 4 334 344 Elev 342 332 327 323 336 I I I I I I I I I I I I I I I I I I I LOW Flow Methods and Data Energy sM~Deve10ped.rep selected Low Flow Methods Highest Energy Answer High Flow Method Energy only Additional Bridge Parameters Add Friction component to Momentum Do not add weight component to Momentum class B flow critical depth computations use critical inside the bridge at the upstream end depth grade line criteria to check for pressure flow = upstream energy BRIDGE OUTPUT profile #PF#l E.G. US. (ft) 338.87 Inside BR DS W.S. US. (ft) 338.41 337.32 Q Total (cfs) 13000.00 337.04 Q Bridge (cfs) 13000.00 329.27 Q weir (cfs) 15.54 weir Sta Lft (ft) 4.20 weir Sta Rgt (ft) 3098.92 weir submerg 0.22 weir Max Depth (ft) 20604.27 Min E1 weir Flow (ft) 349.01 10.50 Min E1 prs (ft) 345.67 354.77 Delta EG (ft) 1.62 202400.6 Delta ws (ft) 1.38 295.03 BR open Area (sq ft) 3874.77 0.06 BR open vel (ft/s) 6.47 0.02 coef of Q 2.25 Br Sel Method Energy only 9.44 Element Inside BR us E.G. Elev (ft) 338.85 w.s. Elev (ft) 338.19 crit W.S. (ft) 332.98 Max chl Dpth (ft) 14.69 vel Total (ft/s) 6.47 Flow Area (sq ft) 2010.35 Froude # ch1 0.40 specif Force (cu ft) 13299.57 Hydr Depth (ft) 7.81 W.P. Total (ft) 305.85 conv. Total (cfs) 107113.1 Top width (ft) 257.50 Frctn Loss (ft) 1.41 c & E Loss eft) 0.11 shear Total (lb/sq ft) 6.04 power Total (lb/ft s) 39.09 warning: The conveyance ratio (upstream conveyance divided by downstream' conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION page 5 I I I I I I I SM~Developed.rep RIVER: San Marcos creek REACH: 1 RS: 10 INPUT Description: Cross section #10 Station Elevation Data num= sta Elev Sta Elev 799.3 350 806.4 348 831.5 340 837.6 338 862.5 330 885.5 330 951.9 323 971 322 1078.5 324 1140.6 330 1169.3 338 1177 340 29 Sta 812.5 843.9 899.3 1000 1147.6 1184.5 Manning's n values num= 3 Sta n val Sta n val Sta 799.3 .1 862.5 .1 1140.6 Elev 346 336 329 321. 5 332 342 n val .1 Bank Sta: Left Right 862.5 1140.6 Lengths: Left channel 198 120.5 Sta 818.9 850.3 904 1033.1 1155.2 1191.8 Right 71.1 Elev Sta 344 825.3 334 856.5 328 910.9 322 1064.7 334 1161. 7 344 coeff contr. . 1 Elev 342 332 327 323 336 Expan . .3 II CROSS SECTION OUTPUT Profile #PF#l I I I I I I II I I I I E.G. Elev (ft) Right OB vel Head (ft) 0.100 W.S. Elev (ft) 71.10 crit W.S. (ft) 87.96 E.G. slope (ft/ft) 87.96 Q Total (cfs) 143.14 TOp Width (ft) 25.00 vel Total (ft/s) 1.63 Max chl Dpth (ft) 3.52 Conv. Total (cfs) 2947.3 Length Wtd. (ft) 25.97 Min ch El (ft) 0.50 Alpha 0.81 Frctn Loss (ft) 5.47 c & E Loss (ft) 1.44 337.25 0.22 337.03 0.002359 13000.00 324.93 3.69 15.53 267673.8 120.06 321. 50 1.04 0.43 0.03 Element Wt. n-val. Reach len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) TOp Width (ft) Avg. vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted per. (ft) shear (1 b/ sq ft) Stream power (lb/ft s) Cum volume (acre-ft) cum SA (acres) Left OB channel 0.100 0.100 198.00 120.50 75.75 3358.78 75.75 3358.78 121.23 12735.63 21. 83 278.10 1. 60 3.79 3.47 12.08 2496.1 262230.3 22.94 278.88 0.49 1. 77 0.78 6.72 0.61 37.79 0.23 3.72 warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. page 6 I I I I I I I I I I I I I I I I I I I CROSS SECTION RIVER: San Marcos creek REACH: 1 RS: 9 INPUT Description: Cross section #9 Station Elevation Data num= Sta Elev Sta Elev 798.7 370 845.7 360 984.7 322 995.5 321 1039.9 323 1119 330 1222 338 1266.2 340 Manning's n values Sta n val Sta 798.7 .1 935.5 num= n val .1 SMC_Developed.rep 17 Sta 875.6 1000 1135.3 3 Sta 1119 Elev Sta 350 911 320.5 1022.2 332 1155.7 n val .1 Bank Sta: Left Right Lengths: Left Channel Right 935.5 1119 CROSS SECTION OUTPUT profile #PF#l E.G. Elev (ft) Right OB vel Head (ft) 0.100 W.S. Elev (ft) 35.00 crit W.S. (ft) 217.48 E.G. slope (ft/ft) 217.48 Q Total (cfs) 455.49 Top Width (ft) 90.06 vel Total (ft/s) 2.09 Max chl Dpth (ft) 2.41 Conv. Total (cfs) 5805.1 Length Wtd. (ft) 90.33 Min ch El (ft) 0.93 Alpha 1.94 Frctn Loss (ft) 5.22 C & E LOSS (ft) 1.35 CROSS SECTION RIVER: San Marcos Creek 336.78 0.52 336.26 0.006156 13000.00 288.90 5.48 15.76 165683.0 79.39 320.50 1.12 0.46 0.04 75 81.4 35 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft Cum volume (acre-ft) Cum SA (acres) Page 7 5) Elev Sta 340 935.5 321 1032.8 334 1207.1 coeff Contr. .1 Left OB 0.100 75.00 48.04 48.04 113.88 15.34 2.37 3.13 1451.4 16.57 1.11 2.64 0.32 0.15 Elev 330 322 336 Expan. .3 Channel 0.100 81.40 2104.95 2104.95 12430.63 183.50 5.91 11.47 158426.4 184.65 4.38 25.87 30.23 3.08 I I SMC_Developed.rep REACH: 1 RS: 8 I INPUT Description: Cross section #8 Station Elevation Data num= 52 Sta Elev Sta Elev Sta Elev Sta Elev Sta Elev I 785.4 370 838.2 360 868 350 891.2 340 926.6 330 992.3 321 1000 320.4 1010.8 321 1061.9 326 1159 330 1180.3 331 1187.9 332 1201 333 1221. 8 334 1224.7 335 1228.6 336 1234.9 337 1242.3 338 1248.2 339 1267.9 340 I 1274.7 339 1280.6 338 1286.7 337 1293.4 336 1297.8 335 1301. 9 334 1320.1 333 1356.6 332 1380.4 331 1385.9 330 1391.1 329 1431. 5 329 1435.3 330 1441. 3 331 1447.5 332 1451. 3 333 1460.2 334 1464 335 1484.9 336 1486.2 337 I 1488.9 337 1490.1 336 1491. 9 335 1493.5 334 1509.8 333 1519.5 334 1522 335 1524 336 1526.6 337 1530.8 338 1540.8 339 1544.3 340 I Manning's n values num= 3 Sta n val Sta n val Sta n val 785.4 .1 926.6 .1 1159 .1 I Bank Sta: Left Right Lengths: Left channel Right coeff Cont r . Expan. 926.6 1159 111.43 120.3 120 .1 .3 Ineffective Flow num= 1 Sta L Sta R Elev Permanent I 1269.7 1544.3 F CROSS SECTION OUTPUT Profile #PF#l I E.G. Elev (ft) 336.28 Element Left OB Channel Right OB vel Head (ft) 0.40 Wt. n-val. 0.100 0.100 I 0.100 W.S. Elev (ft) 335.89 Reach Len. (ft) 111.43 120.30 120.00 crit W.S. (ft) Flow Area (sq ft) 61.32 2361. 89 I 247.57 E.G. slope (ft/ft) 0.005544 Area (sq ft) 61.32 2361. 89 1067.90 Q Total (cfs) 13000.00 Flow (cfs) 135.79 12225.88 I 638.33 TOp Width (ft) 544.46 Top Width (ft) 20.84 232.40 291. 23 vel Total (ft/s) 4.87 Avg. vel. (ft/s) 2.21 5.18 I 2.58 Max chl Dpth (ft) 15.49 Hydr. Depth (ft) 2.94 10.16 3.58 Cony. Total (cfs) 174601. 8 Cony. (cfs) 1823.7 164204.7 I 8573.4 Length Wtd. (ft) 120.20 Wetted per. (ft) 21.65 233.38 69.58 Mi n ch El (ft) 320.40 Shear (lb/sq ft) 0.98 3.50 I 1. 23 Alpha 1.08 Stream power (lb/ft s) 2.17 18.13 3.17 Frctn Loss (ft) 0.75 Cum volume (acre-ft) 0.23 26.06 I 4.70 C & E LOSS (ft) 0.00 Cum SA (acres) 0.12 2.69 1.19 I Page 8 I I I I I I I I I I I I I I I I I I I I SMC_Developed.rep warning: Divided flow computed for this cross-section. CROSS SECTION RIVER: san Marcos Creek REACH: 1 RS: 7 INPUT Description: Cross-Section #7 Station Elevation Data num= 42 Sta E1ev Sta Elev Sta E1ev Sta 690.83 380 700.99 379 708.72 378 715.2 734.77 375 746.46 374 751. 91 373 759.89 786.63 370 810.33 365 825.61 360 834.47 860.33 345 877 .96 340 896.84 335 912.77 976.57 321 991.2 320 1000 319.72 1008.84 1040.6 326 1084.17 327 1117.93 328 1123.73 1157.38 331 1181.4 332 1251. 87 333 1283.74 1295.07 335 1295.07 338 1296.09 338 1303.72 1316.83 347 1322.93 347 Manning's n values num= 3 Sta n val Sta n val Sta n val 690.83 .1 896.84 .1 1040.6 .1 Bank Sta: Left Right 896.84 1040.6 Lengths: Left Channel Right 73.52 100.15 106.36 CROSS SECTION OUTPUT profile #PF#l E.G. Elev (ft) 335.53 Right OB vel Head (ft) 0.45 0.100 W.S. Elev (ft) 335.08 106.36 crit W.s. (ft) 1135.09 E.G. slope (ft/ft) 0.007115 1135.09 Q Total (cfs) 13000.00 3851. 44 TOp Width (ft) 398.53 254.47 vel Total (ft/s) 4.88 3.39 Max ch1 Dpth (ft) 15.36 4.46 Cony. Total (cfs) 154123.4 45661. 3 Length wtd. (ft) 101.04 254.82 Min ch E1 (ft) 319.72 1.98 Alpha 1.20 6.71 Frctn Loss (ft) 0.82 1.67 C & E LOSS (ft) 0.02 0.44 Element Wt. n-va1. Reach Len. (ft) Flow Area, (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. vel. (ft/s) Hydr. Depth (ft) Cony. (cfs) Wetted Per. (ft) shear (1 b/sq' ft) Stream power (lb/ft s) Cum volume (acre-ft) Cum SA (acres) page 9 E1ev sta 377 725.82 372 774.04 355 844.96 330 940.14 320 1026.08 329 1133.52 335 1285.16 340 1313.79 coeff Contr. .1 Left OB 0.100 73.52 0.01 0.01 0.00 0.30 0.14 0.04 0.0 0.31 0.02 0.00 0.15 0.09 E1ev 376 371 350 325 325 330 335 345 Expan. .3 Channel 0.100 100.15 1526.49 1526.49 9148.56 143.76 5.99 10.62 108462.1 145.99 4.64 27.83 20.69 2.17 I I I I I I I I I I I I I I I I I I I SMC_Developed.rep CROSS SECTION RIVER: San Marcos creek REACH: 1 RS: 6 INPUT Description: Cross-Section #6 station Elevation Data num= 51 Sta Elev sta Elev Sta 494.93 400 575.47 390 646.09 717.87 372 729.09 371 743.03 821.87 355 835.98 350 851.78 908.58 330 946.47 325 978.84 1008.06 319 1017.19 320 1033.51 1089.48 327 1099.19 327 1104.43 1136.33 331 1148.98 332 1155.99 1173.87 336 1217.5 336 1240.48 1258.48 337 1259.35 337 1276.22 1283.19 337 1283.19 340 1284.24 1305.12 345 Manning's n values Sta n val sta num= 3 n val Sta 494.93 .1 908.58 .1 1123.14 Elev Sta 380 691.53 370 782.6 345 869.91 320 998.26 325 1050.43 328 1109.3 333 1161.47 336 1243.21 337 1278.89 340 1295.14 n val .1 Bank Sta: Left Right Lengths: Left Channel Right 908.58 1123.14 84.54 84.95 104.32 CROSS SECTION OUTPUT profile #PF#l E.G. Elev (ft) 334.69 Right OB vel Head (ft) 0.61 0.100 W.S. Elev (ft) 334.08 104.32 crit w.s. (ft) 94.28 E.G. slope (ft/ft) 0.009309 94.28 Q Total (cfs) 13000.00 243.76 TOp Width (ft) 271.72 38.68 vel Total (ft/s) 6.09 2.59 Max chl Dpth (ft) 15.48 2.44 Conv. Total (cfs) 134739.2 2526.5 Length wtd. (ft) 85.15 38.93 Min ch El (ft) 318.60 1.41 Alpha 1.06 3.64 Frctn Loss (ft) 0.17 0.87 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) TOp width (ft) Avg. vel. (ft/s) Hydr. Depth (ft) conv. (cfs) wetted per. (ft) shear (1 b/sq ft) Stream Power (lb/ft Cum volume (acre-ft) page 10 Elev Sta 374 703.41 365 805.03 340 885.95 319 1000 326 1068.05 329 1123.14 334 1165.61 336 1248.98 334.5 1281.16 343 1301.19 Elev 373 360 335 318.6 327 330 335 336 337 343 coeff Contr. Expan. .1 .3 Left OB Channel 0.100 0.100 84.54 84.95 37.74 2004.24 37.74 2004.24 85.72 12670.52 18.48 214.56 2.27 6.32 2.04 9.34 888.5 131324.3 18.93 216.45 1.16 5.38 s) 2.63 34.02 0.12 16.63 I I I I I I I I I I I: I I I I I I I I C & E Loss (ft) 0.09 SMC_Developed.rep 0.01 Cum SA (acres) CROSS SECTION RIVER: San Marcos creek REACH: 1 RS: 5 INPUT Description: Cross-section #5 Station Elevation Data num= 40 Sta Elev Sta Elev Sta 556.43 400 621.34 390 661.36 712.94 365 731.07 360 764.68 834.73 340 854.24 335 873.72 994.55 319 1000 318.33 1010.91 1042.53 326 1049.61 327 1065.12 1077.18 329 1081.03 330 1097.16 1153.06 350 1164.99 351 1175.25 1247.54 350 1259.68 349 1274.6 Manning's n values Sta n val Sta num= 3 n val Sta 556.43 .1 873.72 .1 1081. 03 Elev Sta 380 678.15 355 791. 66 330 913.94 319 1018.9 327 1073.66 335 1111. 87 352 1209.45 348 1305.63 n val .1 Bank Sta: Left Right 873.72 1081. 03 Lengths: Left Channel Right 106.38 83.7 84.95 CROSS SECTION OUTPUT profile #PF#l E.G. Elev (ft) 333.81 Right OB vel Head (ft) 0.72 0.100 W.S. Elev (ft) 333.10 84.95 crit W.S. (ft) 15.46 E.G. slope (ft/ft) 0.011158 15.46 Q Total (cfs) 13000.00 31. 50 Top Width (ft) 229.36 9.99 vel Total (ft/s) 6.73 2.04 Max chl Dpth (ft) 14.77 1. 55 Cony. Total (cfs) 123071.4 298.2 Length wtd. (ft) 83.74 10.46 Min ch El (ft) 318.33 1.03 Alpha 1.02 2.10 Frctn LOSS (ft) 1.04 0.04 C & E LOSs (ft) 0.01 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) TOp Width (ft) Avg. vel. (ft/s) Hydr. Depth (ft) Cony. (cfs) Wetted Per. (ft) Shear (lb/sq ft) Stream Power (lb/ft Cum volume (acre-ft) Cum SA (acres) Page 11 0.07 Elev Sta 375 695.92 350 819.29 325 989.76 320 1036.74 327 1075.63 340 1129.67 352 1225.19 347.21 1332.66 s) coeff Cant r . .1 Left OB 0.100 106.38 18.67 18.67 38.39 12.06 2.06 1. 55 363.5 12.45 1.04 2.15 0.06 0.04 1. 76 Elev 370 345 320 325 328 345 351 354.3 Expan. .3 Channel 0.100 83.70 1896.62 1896.62 12930.11 207.31 6.82 9.15 122409.8 209.52 6.31 42.99 12.83 1. 35 I I I I I I I I I 'I I 'I I I I I I I I SMC_Developed.rep 0.03 warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: San Marcos creek REACH: 1 RS: 4 INPUT Description: cross-Section #4 station Elevation Data num= 41 sta Elev Sta Elev Sta 678.28 400 716.25 390 735.55 782.31 370 801.95 365 816.66 859.68 345 874.58 340 895.96 972.9 320 983.33 319 994.86 1011.51 319 1033.43 320 1047.25 1070.6 326 1075.28 329 1098.95 1129.34 340 1144.92 345 1160.54 1227.4 362 1263.88 362 1282.93 1358.23 355.7 Manning's n values Sta n val Sta num= 3 n val Sta 678.28 .1 908.77 .1 1108.25 Elev Sta 385 753.13 360 831. 54 335 908.77 318 1000 320 1060.67 329 1108.25 350 1182.45 360 1322.33 n val .1 Bank Sta: Left Right 908.77 1108.25 Lengths: Left channel Right 77.73 90.76 77.43 CROSS SECTION OUTPUT profile #PF#l E.G. Elev (ft) 332.77 Right OB vel Head (ft) 0.84 0.100 w.s. Elev (ft) 331.92 77.43 crit w.s. (ft) 4.25 E.G. slope (ft/ft) 0.013805 4.25 Q Total (cfs) 13000.00 6.82 TOp width (ft) 208.82 4.42 vel Total (ft/s) 7.34 1.61 Max chl Dpth (ft) 14.48 0.96 Conv. Total (cfs) 110643.1 58.0 Length wtd. (ft) 90.75 4.82 Min ch El (ft) 317.44 0.76 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) TOP width (ft) Avg. vel. (ft/s) Hydr. Depth (ft) Conv. (cfs) wetted Per. (ft) shear (lb/sq ft) Elev Sta 380 767.74 355 843.82 330 940.33 317.44 1005.14 320 1069.44 330 1119.74 355 1209.64 356 1348.43 coeff Cont r . .1 Left OB 0.100 77 .73 4.74 4.74 7.68 4.93 1. 62 0.96 65.4 5.29 0.77 Alpha 1.01 Stream power (1 b/ft s) 1.25 page 12 Elev 375 350 325 318 325 335 360 355 Expan. .3 channel 0.100 90.76 1761. 91 1761. 91 12985.50 199.48 7.37 8.83 110519.7 203.14 7.48 55.09 I I I I I I' I I I I I I I I I I I I I SMC_Developed.rep 1.22 Frctn Loss (ft) 1.23 Cum volume (acre-ft) 0.04 9.31 0.02 C & E Loss (ft) 0.01 Cum SA (acres) 0.02 0.96 0.01 warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: San Marcos Creek REACH: 1 RS: 3 INPUT Description: Cross-section #3 Station Elevation Data num= 55 Sta Elev Sta Elev Sta 756.56 400 .782 395 797.74 834.12 375 845.86 370 861. 01 891. 99 350 899.97 345 908.29 949:34 325 968.54 320 981. 81 998.51 316 1000 315.9 1001. 49 1038.01 319 1054.64 320 1063.98 1081.19 320 1090.94 325 1096.42 1136.48 335 1151. 92 340 1184.21 1244.92 366 1265.74 367 1287.71 1322.77 366 1330.54 365 1337.32 1400.02 358 1406.82 357 1410.77 Manning's n values Sta n val Sta num= 3 n val Sta 756.56 .1 929.59 .1 1096.42 Elev Sta 390 809.19 365 871.59 340 917.99 319 988.18 316 1013.47 320 1074.56 330 1104.95 350 1216.77 368 1290.89 364 1382.59 357 1425.17 n val .1 Bank Sta: Left Right Lengths: Left Channel Right 929.59 1096.42 62.17 102.86 114.21 CROSS SECTION OUTPUT Profile #PF#l E.G. Elev (ft) 331.53 Right OB vel Head (ft) 0.94 0.100 W.s. Elev (ft) 330.59 114.21 Crit W.S. (ft) 0.37 E.G. slope (ftjft) 0.013230 0.37 Q Total (cfs) 13000.00 0.26 Top Width (ft) 169.45 1.26 vel Total (ftjs) 7.78 0.71 Max chl Dpth (ft) 14.69 0.29 Cony. Total (cfs) 113020.2 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) Top Width (ft) Avg. vel. (ftjs) Hydr. Depth (ft) Cony. (cfs) Page 13 Elev Sta Elev 385 820.36 380 360 882.06 355 . 335 929.59 330 318 991.86 317 317 1021. 52 318 319 1076.35 31:9 334 1124.08 334 360 1236.15 365 368 1309.25 367 360 1389.89 359 357 1433.14 358.6 coeff Contr. Expan. .1 .3 Left OB Channel 0.100 0.100 62.17 102.86 0.40 1670.24 0.40 1670.24 0.29 12999.45 1. 37 166.83 0.71 7.78 0.29 10.01 2.5 113015.4 I I I I I I' I. I I I I I I I I I I I SMC_Developed.rep 2.3 Length Wtd. (ft) 102.86 wetted per. (ft) 1.49 171.88 1. 39 Min ch El (ft) 315.90 shear (lb/sq ft) 0.22 8.03 0.22 Alpha 1.00 Stream Power (lb/ft s) 0.16 62.47 0.16 Frctn LOSS (ft) 1.72 Cum Volume (acre-ft) 0.03 5.73 0.01 C & E Loss (ft) 0.05 Cum SA (acres) 0.02 0.58 0.01 warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: San Marcos creek REACH: 1 RS: 2 INPUT Description: Cross-section #2 Station Elevation Data num= 44 Sta Elev Sta Elev Sta 817.95 390 835.8 385 848.86 886.76 365 897.43 360 907.12 937.72 340 945.29 335 955.45 992.43 316 995.62 315 1000 1022.62 317 1040.86 317 1070.99 1095.8 330 1112.35 330 1124.85 1145.49 330 1163.01 335 1179.36 1223 355 1240.82 360 1256.16 1427.66 360 1472.02 358 1477.48 Manning's n values Sta n Val Sta num= 3 n Val Sta 817.95 .1 955.45 .1 1095.8 Elev Sta 380 861. 86 355 915.7 330 964.03 314.34 1004.39 317 1079.24 329 1132.22 340 1191. 6 365 1318.92 357.6 1501. 06 n val .1 Bank Sta: Left Right 955.45 1095.8 Lengths: Left Channel Right CROSS SECTION OUTPUT E.G. Elev (ft) Right OB Vel Head (ft) W.S. Elev (ft) 63.34 Crit W.S. (ft) E.G. slope (ft/ft) Q Total (cfs) 181.76 92.2 63.34 Profile #PF#l 329.76 1.48 328.27 0.021693 13000.00 Element Wt. n-val. Reach Len. (ft) Flow Area (sq ft) Area (sq ft) Flow (cfs) page 14 Elev Sta 375 874.73 350 925.43 325 974.02 315 1011. 84 320 1089.41 328.33 1142.44 345 1208 369.8 1372.13 358.6 coeff Contr. .1 Left OB 181. 76 Elev 370 345 320 316 325 329 350 365 Expan. .3 Channel 0.100 92.20 1329.82 1329.82 13000.00 I I 'I I I I: I I I I I I' I I I I I I TOp Width (ft) SMC_Developed.r~ 135.19 TOp Width ( t) 135.19 vel Total (ft/s) 9.78 Avg. vel. (ft/s) 9.78 Max chl Dpth (ft) 13.93 Hydr. Depth (ft) 9.84 Conv. Total (cfs) 88263.4 Conv. (cfs) 88263.4 Length wtd. (ft) 92.38 wetted per. (ft) 140.87 Min ch El (ft) 314.34 shear (lb/sq ft) 12.79 Alpha 1.00 Stream power (lb/ft s) 124.98 Frctn Loss (ft) 1.16 Cum volume (acre-ft) 0.03 2.19 0.01 C & E Loss (ft) 0.31 Cum SA (acres) 0.02 0.22 0.01 warning: The velocity head has changed by more than 0.5 ft (0.15 m). This may indicate the need for additional cross sections. warning: The conveyance ratio (upstream conveyance divided by downstream conveyance) is less than 0.7 or greater than 1.4. This may indicate the need for additional cross sections. warning: The energy loss was greater than 1.0 ft (0.3 m). between the current and previous cross section. This may indicate the need for additional cross sections. CROSS SECTION RIVER: San Marcos creek REACH: 1 RS: 1 INPUT Description: Cross-Section #1 Dis (Dr. chang's Cross section #6.047) station Elevation Data num= 35 sta Elev sta Elev sta 879.61 353.9 893.38 350 911.57 948.88 330 957.68 325 968.62 985.29 313 989.11 312 1000 1030.85 314 1034.87 315 1042.44 1060.24 327 1131.57 327 1135.93 1170.78 345 1186.7 350 1204.59 1269.54 369 1349.66 365 1408.31 Manning's n values Sta n val sta num= 3 n val sta 879.61 .035 968.62 .035 1042.44 Elev Sta 345 924.79 320 974.88 311. 76 1010.89 320 1054.34 330 1140.53 355 1223.18 360 1458.18 n val .035 Bank sta: Left Right 968.62 1042.44 Lengths: Left Channel Right o CROSS SECTION OUTPUT E.G. Elev (ft) Right OB vel Head (ft) profile #PF#l 328.29 4.58 o 0 Element Wt. n-val. page 15 Elev Sta 340 937.35 315 980.16 312 1025.07 325 1056.34 335 1150.46 360 1239.57 357.21 1480.39 coeff Cont r . .1 Left OB 0.035 Elev 335 314 313 326 340 365 358.65 Expan. .3 Channel 0.035 I: I I I' I I I I I I I I I I I I I I I SMC_Developed.rep 0.035 W.S. Elev (ft) 323.71 Reach Len. (ft) crit W.S. (ft) 323.71 Flow Area (sq ft) 15.05 742.26 16.37 E.G. slope (ft/ft) 0.008168 Area (sq ft) 15.05 742.26 16.37 Q Total (cfs) 13000.00 Flow (cfs) 81.80 12828.42 89.78 TOP Width (ft) 90.76 Top Width (ft) 8.11 73.82 8.83 vel Total (ft/s) 16.80 Avg. Vel. (ft/s) 5.44 17.28 5.49 Max chl Dpth (ft) 11. 95 Hydr. Depth (ft) 1.85 10.06 1.85 Conv. Total (cfs) 143845.6 Conv. (cfs) 905.1 141947.0 993.5 Length wtd. (ft) wetted Per. (ft) 8.92 77 .64 9.57 Min ch El (ft) 311. 76 shear (lb/sq ft) 0.86 4.87 0.87 Alpha 1.05 Stream Power (lb/ft s) 4.67 84.25 4.78 Frctn Loss (ft) Cum volume (acre-ft) C & E Loss (ft) Cum SA (acres) warning: slope too steep for slope area to converge during supercritical flow calculations (normal depth is below critical depth). water surface set to critical depth. SUMMARY OF MANNING'S N VALUES River:san Marcos creek Reach River sta. n1 n2 n3 1 11 .1 .1 .1 1 10.5 Bridge 1 10 .1 .1 .1 1 9 .1 .1 .1 1 8 .1 .1 .1 1 7 .1 .1 .1 1 6 .1 .1 .1 1 5 .1 .1 .1 1 4 .1 .1 .1 1 3 .1 .1 .1 1 2 .1 .1 .1 1 1 .035 .035 .035 SUMMARY OF REACH LENGTHS River: San Marcos creek Reach River Sta. Left Channel Right page 16 .---~ I I I I I I I I I I I ',I I I I I I I I SMC_Developed.rep 1 11 219 219 219 1 10.5 Bridge 1 10 198 120.5 71.1 1 9 75 81.4 35 1 8 111.43 120.3 120 1 7 73.52 100.15 106.36 1 6 84.54 84.95 104.32 1 5 106.38 83.7 84.95 1 4 77.73 90.76 77.43 1 3 62.17 102.86 114.21 1 2 181. 76 92.2 63.34 1 1 0 0 0 SUMMARY OF CONTRACTION AND EXPANSION COEFFICIENTS River: San Marcos creek Reach River sta. contr. Expan. 1 11 .1 .3 1 10.5 Bridge 1 10 .1 .3 1 9 .1 .3 1 8 .1 .3 1 7 .1 .3 1 6 .1 .3 1 5 .1 .3 1 4 .1 .3 1 3 .1 .3 1 2 .1 .3 1 1 .1 .3 Profile output Table -standard Table 1 Reach River Sta profile Q Total Mi n ch El W.S. Elev crit W.S. E.G. Elev E.G. slope vel chnl Flow Area TOP Width Houde # chl (cfs) (ft) (ft) (ft) (ft) (ft/ft) (ft/s) (sq ft) (ft) 1 11 PF#l 13000.00 323.50 338.41 332.22 338.87 0.007496 5.42 2411.34 289.12 0.32 1 10.5 Bridge 1 10 PF#l 13000.00 321. 50 337.03 337.25 0.002359 3.79 3522.49 324.93 0.19 1 9 PF#l 13000.00 320.50 336.26 336.78 0.006156 5.91 2370.47 288.90 0.31 1 8 PF#l 13000.00 320.40 335.89 336.28 0.005544 5.18 2670.78 544.46 0.29 1 7 PF#l 13000.00 319.72 335.08 335.53 0.007115 5.99 2661.59 398.53 0.32 1 6 PF#l 13000.00 318.60 334.08 334.69 0.009309 6.32 2136.27 271. 72 0.36 1 5 PF#l 13000.00 318.33 333.10 333.81 0.011158 6.82 1930.75 229.36 0.40 1 4 PF#l 13000.00 317.44 331. 92 page 17 I I I I 'I' I I' I I I I J I I I I I I I 1 1 1 332.77 0.013805 3 331. 53 0.013230 2 329.76 0.021693 1 328.29 0.008168 SMC_Developed.rep 7.37 1770.89 208.82 0.44 PF#l 13000.00 315.90 330.59 7.78 1671.01 169.45 0.43 PF#l 13000.00 314.34 328.27 9.78 1329.82 135.19 0.55 PF#l 13000.00 311. 76 323.71 323.71 17.28 773.68 90.76 0.96 page 18 I: I I' I I: .' Ii I I: . I I, . I I . I .1 I .. ' I I ,I; I: v I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 5 PRE-DEVELOPED CONDITIONS FLOODPLAIN EXHIBIT DE:de h:\reporlsI175111361clomrlclom,_01.doc w.o.1751-136 315/20072:26 PM / I; \ "- I '1 I I I I- I I I' I VI I. I I I I I I ·1' I I I I I I I I I I I I I I I I I I I La Costa Ridge 2.6 Conditional Letter of Map Revision Based on Fill CHAPTER 6 DEVELOPED CONDITIONS . FLOODPLAIN EXHIBIT DE:de h:lreports\1751\1361c1omrlclomr_Ol.doc w.o.1751-136 3/5/20072:26 PM Ii x , ' , , / / ~"/ / / \ 1 , ( ( I , r _ \ . 1 / / , I / " _-'. , . LEGEND , I I , I \\ ~- \ PROPOSED FLOODPLAIN EXISTING FLOODPLAIN FLOWLINE CROSS SECTION Iii i " , ',I i , il I ,. ! 'i , \ _ .. _ ... _ .. , ! ' , , \ , i , , i , / / / / / / ,~---- 4 , " ------ '. -"-- ------ -'-. ," .' .' -- --"'- ,,-'-~ ". •...... ~ " '---, . .' ,~, X , , \\ 'Jf' . ---"'/ ,/,~-~_- ,.,' ,/ ! , ' ---- '-'-'-, _.,., DATUM NOTE: NGVD 1929 VERTICAL DATUM USED ~, X PREPARED BY: HUNSAKER & ASSOCIATES S AN DIE C o, IN C. PlANNING 10179 Huemeken> Street ENGINEERING San Diego. Ca 92121 SURVEYING PH(8S8)558-4SOO· FX(3S8)s58-1414 , i \ , ' , l ! L ~ -\-, :1-. ,. I : I· -'-I' i ! I NITYMAP NTS DEVELOPED FLOODPLAIN EXHIBIT FOR LA COSTA RIDGE NEIGHBORHOOD 2.6 CITY OF CARLSBAD, CAUFORNIA / SHEET 1 OF 1 R.\0459\8.Hycl\0459$Hll-DEY -HECRAS,clwg[ 20B5JMnr-06-2007.0B.OB .. o TENTATIVE CARLSBAD TRACT MAP NO.' CT 05-13 & CONDOMINIUM PE'RMIT NO. CP 05-12 COSTA RIDGE NEIGHBORHOOD 2.6 '. \ '''. , ""--" ... ~. ,-----.--~ '-.-. , . , .. .,·-A--~--- ( PROJECT MAP PARKING SUMMARY PARKING REQUIRED DU's # SPACES/DU" SINGLE FAMILY 53 2 5 SPACES (FOR 1 ST 10 UNITS) VISITOR PARKING 53 .3 SPACES X43* (FOR REMAINING UNITS) SUBTOTAL TOTAL 53 ALL STANDARD SPACES TOTAL SPACES 106 5 12.9 17.9 124 *PER L A COSTA OAKS VILLAGE DEY. STANDARDS 7.7.3.8 K (PARKING REQ'D PER CARLSBAD MUNICIPAL CODE SECTION 21.44) . PARKING PROVIDED DU's #SPACES/DU TOTAL SPACES SINGLE FAMILY FULL-SIZED (IN GARAGE) 53 2 106 VISITOR PARKING' 53 2 SPACES/UNIT* 106 TOTAL 53 --212 'VISITOR PARKING ALLOWED IN STREET F 1 STREET SPACE AND 1 DRIVEWAY SPACE PER UNIT. SCALE: 1"= 100' ARCHITECTURE SUMMARY PLAN 1st FLOOR 2nd FLOOR LIVING GARAGE TOTAL BLDG FOOTPRINT NO. SQ. FT. SQ. FT. SQ. FT. SQ. FT. SQ. FT. SQ. FT. 1 908 1,069 1,977 429 2,406 1,337 2 931 1,090 2,021 445 2,466 1,376 3 1,120 1,236 2,356 428 2,784 1,548 BUILDING COVERAGE SUMMARY PLAN NO. #OF %MIX FOOTPRINT TOTAL BLDG. UNITS SQ. FT. COVERAGE 1 8 15% 1,337 10,696 2 23 43% 1,376 31,648 3 22 42% 1,548 34,056 TOTAL 53 100% 76400 , T CITY OF ENCINITAS VICINITY MAP N I MASTER TEN" n'l""_../ MAP B01IND,4RY NTS T MASTER TENTA TIllE MAP BOUNDARY G o LA COSTA VICINITY MAP Nrs CONDOMINIUM NOTE THIS SUBDIVISION IS A CONDOMINIUM PROJECT AS OEFINED IN SECTION 1351 OF THE CIVIL CODE OF THE STATE OF CALIFORNIA AND FILED PURSUANT TO THE SUBDIVISION MAP ACT. THE TOTAL NUMBER OF CONDOMINIUM UNITS FOR THIS PROJECT IS 53, AND THE TOTAL NUMBER OF LOTS IS 10. SEE BREAKDOWN BELOW. LOT 1 = 7 UNITS LOT 2 = 15 UNITS LOT 3 = 13 UNITS LOT 4 = 14 UNITS LEGEND SUBDIVISION BOUNDARY LOT LINE EXCLUSIVE USE AREA EXISTING LOT NUMBER PROPosm LOT NUMBER WITH PAD ELEVA TlON EARTHEN SWALE TERRACE DRAIN BROW DITCH RIPRAP (ENERGY DISSIPA TER) EASEMENT LINE TITLE REPORT ITEM NO. SLOPE (2: 1 MAX) PROPOSED % OF GRAOE EXISTING SEWER MAIN PROPOSED SEWER MAIN (8" PVC UNLESS OTHERWISE NOTED) EXISTING WATER MAIN WITH FIRE HYDRANT PROPOSED WA TER MAIN WITH FIRE HYDRANT (8" PVC UNLESS OTHERWISE NOTED) EXISTING RECLAIMED WA TER PROPOSED RECLAIMED WA TER EXISTING STORM DRAIN SYSTEM PROPOSED PRIVA TE STORM DRAIN SYSTEM A. INLET OR CA TCH BASIN B. HEADWALL C. CLEANOUT RETAINING WALL EXISTING SPOT ELEVA TlONS PROPOSED SPOT ELEVA TlON EXISTING CONTOURS PROPOSED CONTOURS EXISTING STREET LIGHT PROPOSED STREET LIGHT EXISTING TRAIL PROPOSED TRAIL PROPOSED SOUND WALL PLAN TYPE ELEVA TlON AND COLOR SCHEME TOP OF WALLj FINISHED SURFACE --,..--------- LoT 270 CID P 736.6 • -01IIII_- (jJ -~~-___ '-.1. ___ _ -------1.") --....,.--<0 ----W-'!'-- --W~- ----RW---- ---RW-- =-='= - -==1(J (2,55.5) 237.7 _0 000 0000 0 < 00 a 0 _ 0 0 00 0 rn <EC-I? 349.7TW J45.7FS PUBLIC UTILITIES AND DISTRICTS GAS AND ELECTRIC ............. SAN DIEGO GAS AND ELECTRIC COMPANY TELEPHONE .................... PACIFIC BELL TELEPHONE . WA TER ........... _ . .. . . . . . . . .. VALLEe I TOS WA TER D I STR I CT SEWER .....•.................. VALLECITOS WATER DISTRICT STORM DRAIN .................. PRIVATE (HOA) POLiCE •...................... CITY OF CARLSBAD SCHOOLS ...................... SAN MARCOS SCHOOL DISTRICT CABLE. . . . . . . . . . . . . . . . . . . . . . .. ADELPH I A RECLAIMED WATER .............. VALLECITOS WATER DISTRICT ABBREVIATIONS FL FLOW LINE IE INVERT ELEVATIDN TW TOP OF WALL R/W RIGHT OF WAY BW BOTTOM OF WALL PL PROPERTY LINE TF TOP OF FOOTI NG GB GRADE,BREAK FS FINISH SURFACE PI POINT OF INTERSECTION (V. C.) S SEWER P PAD ELEVAT /ON W WATER SF GROSS SO. FT. RW RECLAIMED WATER NSF NET SO. FT. SO STORM OF?A IN FP FLOOD PLAIN NTS NOT TO SCALE VC VERTICAL CURVE ELEV ELEVATION MH MANHOLE RCP REINFORCED CONCRETE PIPE LEGAL DESCRIPTION LA COSTA RIDGE NEIGHB~HDOO 2.6 LOT 223 OF CITY OF CARLSBAD TRACT CT 99-04-02, V I LLAGES OF LA COSTA -LA COSTA RIDGE -NEIGHB~HDOD 2.6, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, STATE OF CALlF~NIA, ACCORDING TO MAP NO. THEREOF NO. 14838 F I LEO I N THE OFF! CE OF THE COUNTY RECORDER OF SAN 0 I EGO COUNTY ON JUL Y 14, 2004. EARTHWORK / GRADING QUANTITIES TOTAL PROJECT RAW CUT: 52,700 C. Y. RA W FILL: 20,600 C. Y. eXPORT: 32,100 C. Y. TOTAL GRADED AREA: 9.0 ACRES (5,860 c. Y./AC.) CT 05-13/CP 05-12 GENERAL NOTES 1. TOTAL GROSS SITE AREA: 10.8 ACRES TOTAL NET SITE AREA: 9.1 ACRES (NET = GROSS SITE AREA - CORINTIA ST. -MELROSE DR. VACATION -RANCHO SANTA FE RD.) 2. EXISTING LAND USE: VACANT -MASS GRADED (PER DRAWING 397-3F) 3. PROPOSED LAND USE: MULTI-FAMILY DETACHED RESIDENTIAL AND OPEN SPACE 4. TOTAL NUMBER OF DWELLING UNI TS: 53 5. TOTAL NUMBER OF LOTS: 10 6. ASSESSOR'S PARCEL NUMBER: 223-720-03 7. EX I ST I NG GENERAL PLAN LAND USE DES I GNA T ION: RMH (RESIDENTIAL MEDIUM-HIGH DENSITY {B-15 dulac}) 8. EXISTING ZONING: PC . 9. MASTER PLAN UNDERLYING ZONING: RD-M (RESIDENTIAL DENSITY-MULTIPLE) 10. GROSS DENSITY: 5.4 DU/AC (53 DU'S/9.B AC.) 11. LFMP ZONE: ZONE 11 12. AVERAGE DAILY TRIPS: 424 (53 UNITS x B TRIPS/DAY) 13. BUILDING COVERAG£: I.B ACRES (15.2%) 14. PERCENT LANDSCAP I NG: APPROX I MA TEL Y 49. 6% GENERAL [)ESIGN NOTES 1. ALL GRAD I NG FOR PROPOSED AND FUTURE STREETS SHALL CONFORM TO THE CITY OF CARLSBAD DESIGN STANDARDS AND AS REQUIRED BY THE CITY ENGINEER. 2. ALL EASEMENTS SHALL BE PROVIDED, REMOVED OR RELOCATED AS REQUIRED BY THE CITY ENGINEER, PUBLIC UTILITIES AND THEIR APPROPRIATE DISTRICTS. 3. ALL PROPOSED UTILITIES SHALL BE INSTALLED UNDERGROUND. ( ) 4 SOURCE OF TOPOGRAPHY: SAN-LO AERIAL SURVEYS, FLOWN 5-2-2000 OFFSITE . AND DlIGITAL MAPPING, INC, FLOwN 12-20-2005 (ONSIT£) 5. CONTOURED INTERVALS: 1'/5' FEET 6. MANUFACTURED SLOPE RATIOS SHALL BE VARIABLE (2: 1 MAX)..· . 7. FINISHED GRADES ARE APPROXIMATE ONLY AND SUBJECT TO CHANGE AT FINAL DESIGN, CONSISTENT WITH THE CITY'S SUBSTANTIAL CONFORMANCE GUIDELINES, 8. SOILS INFORMATION WAS OBTAINED FROM THE PRELIMINARY . SOILS REPORT PREPARED BY: PACIFIC SOILS DATED: JUN-02-05 9. EXACT GRADING DESIGN AND BROWDITCH LOCATION AND SIZING SHALL BE DONE AT FINAL ENGINEERING PER TIE FiNAL GRADING PLAN AND APPROVED HYDROLOGY REPORT. 10. GRADED SWALES SHALL HAVE A MINIMUM OF 1% FLOW LINE GRADE. DRA I NAGE OUTLHS THA T ARE I NACCESS I BLE SHALL USE A "0-4 t" OUTLET DISSIPATERS INSTEAD OF RIPRAP FIELDS. EXACT LOCATIONS TO BE D£TERM I NED AT FINAL ENG I NEER I NG. 11. ALL STREET DESIGNS, STREET LIGHT, AND FIRE HYORANTS TO CONFORM. TO CITY OF CARLSBAD DESIGN STANDARDS AND AS REQUIRED BY CITY ENGINEER. 12. LANDSCAPING AND TREE PLANTING SHALL BE PER THE CARLSBAD LANDSCAPE MANUAL AND THE VILLAGES OF LA COSTA MASTER PLAN. (SEE MASTER LANDSCAPE PLAN FOR THE RIDGE) 13. ALL STREET DESIGN SH4LL CONFORM TO THE CI TY OF CARLSBAD DESIGN STANDARDS AND AS REQUIRED BY TIE CITY ENGINEER. 14. CUL-DE-SAC CURB. GRADES SHALL BE A MINIMUM OF 1%. 15. THE SUBDIVIDER/DEVELOPER SHALL PROVIDE AND INSTALL APPROVED STREET LIGHT STANDAROS AND FIXTURES IN THE TYPE AND NUMBER APPROVED BY . THE CITY OF CARLSBAD, THE PUBLI C WORKS DEPARTMENT -TRAFFI C SECTI ON AND PER THE CITY'S STREET LI GHT CONSTRUCT ION STANDARDS. STREET LIGHTS AS SHOWN ON THIS MAP ARE TO BE USED AS A GUIDE ONLY. 16. THIS TM ASSUMES CERTAIN BACKBONE INFRASTRUCTURE IS EXISTING OR APPROVED AND BONDED FOR TO THE SA T I SF ACT I ON OF THE CITY ENG I NEER. THEY INCLUDE BUT ARE NOT LIMITED TO PORTIONS OF CORINTIA STREET. 17. AVERAGE SEWER GENERATION: APPROX .02 MGD (FOR 53EDU's) WA TER PRESSURE ZONE: 640 AVERAGE POTABLE WATER DEMAND: 71.3 GPM, 164.0 GPM PEAK FIRE FLOW DEMAND: 2500 GPM AT EACH FIRE HYDRANT. 18. WHERE NECESSARY INORDER TO MEET THE 5' MINIMUM POSITIVE DRAINAGE ON SIDEYARDS, DEEPENED FOOTINGS WILL BE UTILIZED AS ALLOWED PER PACIFIC SOILS ING., LETTER DA TED JANUARY 16, 2006. 19. PRIOR TO THE ISSUANCE OF A PRECISE GRADING PERMIT OR ANY BUILDING PERMITS, THE EXISTING IMPROVEMENT DRAWINGS SHALL BE CONSTRUCTION CHANGED TO SHOW THE RELOCATION OF ANY DRIVEWAYS, SEWER AND WATER LATERALS WHICH MAY CONFLICT WITH ANY CITY STANDARDS OR PROPOSED RES IDENTI AL UN I TS/DR I VEWA YS. 20. ANY RESIDENTIAL STRUCTURES OR PORTIONS OF THE STRUCTURE SUCH AS DECKS/PATIOS/BALCON\ES THAT ARE WITHIN FIRE PROTECTION ZONES SHALL BE FIRE RATED AND MADE OF IGNI TlON RESISTANT CONSTRUCTION. . " . OWNER' SUBDIVIDER WESTERN PACIFIC HOUSING, I~. 5790 FLEET STREET DR HORTON: WESTERN PACIFIC SERIES 5790 FLEET STREET SUITE 210 CARLSBAD CA, 92008 (760) 929-1600 .,;>.-.--~ - c SUITE 210 CARLSBAD CA, 92008 (760) 929-1600 S ;~4£&' , REPRES~TA TlVE. V,cE RZBSrA9V'T DAVID A. HAMMAR R.C.E. 34757 MY REGISTRATION EXPIRES ON 9/30/07 PREPARED BY: NO. REVISIONS 1 1st SUBMITTAL 2 RESUBMITT AL HUNSAKER 3 RESUBMITTAL & ASSOCIATES 4 RESUBMI IT AL SAN DIEGO, INC 5 SUBMITTAL FOR PC HEARING PlANNING 10179 Huennekens Street 6 ENGINEERING San [);ego, Ca 92121 7 SURVEYING PH(656)S58-4S<lO· FX{85S)S5& 1414 8 9 TENTATIVE MAP/CONDOMINIUM PERMIT LA COSTA RIDGE NEIGHBORHOOD 2.6 DATE DATE BY 06/22/05 JHA 10/25/05 JHA 01/19/06 JHA 04/07/06 JHA 07/12/06 JHA SHEET 1 OF VILLAGES OF LA COSTA 6 cj ~ __________________________________________________________________________ ~ _____________________________________________________________________ 1-______ ~C~ity~·~O~f~c:a~rIS~b~a~d~l.~C~a~lif~O~rn~ia~~~~~~~~ R,\0459\&Pln\ TM Sht l.dwg[lJuI-12-2006,0860 LOT 5 = 4 UNITS H&A 3!5!2()07 5C" P'U8UC STREET / PU8UC UTiLiTY EASEMENT ?('(f +-----------------------------------------------f ;6' FENCE/LOT LINE PUBLIC LOCAL STREET EXISTING CORINTIA STREET PER DRAWING NO. 368-28 (STATION 11+10 TO 11+90) DRAWING NO. 397-3 (STATION 79+09 TO 82.01) DRAWING NO. 397-30 (STA TlON 43+40 TO 51.30) ORA WING NO. 200--2 ,C{ /V/ SC;U (j-if..F::L Y e/l! . MELROSE DRIVE STA 208+81.64 TO 212+33.88 PER ORA WING NO. 368-28 RANCHO SANTA FE ROAD STA 281 +25.00 TO 284+37.26 PER DRAWING NO. 368-28 RANCHO SANTA FE ROAD STA 281 +25.00 TO 284+37.26 PER ORA WING NO. 368 2B PAD NTS NTS NTS NTS WALL NDl1~dEPLY J\'/W ,''10.:;: ri--tF F([ r H/W ----~~ CONCf-?E -;E WAL.,i( TYPICAL EXISTING STREET SECTIONS ROW-----, SIDEWALK\ \ < ..• ' ...•.. ' L."·....". '. -. I ! \" . I: (' : '. L. i:. "", .... -, .. ',.", ~ '."' \ .< , ~ \". , / 1\ CURB-J/ TYPICAL DRIVEWA Y CUT DETAIL SCALE 1 "=20' 0(0,0 ~<" ,.;, <?- " ~i' ~~ 1?e1-J- ~. '-'::;z RETAINING WALL WHERE SHOWN PROPERTY LINE ~ B' J'" PROPOSED STABILIZED DECOMPOSED GRANITE TRAIL CONCRE E WALK OVER B OW DITCH ,.," '-'-" I_f-J./!l~ -/III 1111_' ., 111= -III =1/11= BROW DITCH SECTION A-A .( .,'''' .. . PROPOSED ONISTE PUBLIC TYPICAL CITY WIDE TRAIL SECTION 0( dh-~ ,;>. ~i' v.. '1'-/-~. ~z RETAINING WALL WHERE SHOWN PROPER TY LINE ~ 8' 3' " PROPOSED 6' WIDE STABILIZED DECOMPOSED GRANITE TRAIL 2' SECTION B-B BROW 0 TCH NTS PROPOSED ONSITE PUBLIC TYPICAL CITY WIDE TRAIL SECTION NTS l' SHOULDER FOIff-=j~-,6,-' .:.:TR;:..A",IL",E",A",SE",M",EN:..;.T_TI' SHOULDER FOR SLOPES EXCEEDING 4: I 4' SLOPES EXCEEDING 4: I 0( ~O,o<" 1..:>. ~7 v.. ~'1'-t..J ~ BROW DITCH RETAINING WALL SECTIONC-C PROPOSED ONSITE PRIVATE TRAIL CONNECTION TYPICAL SECT/ON l' SHOULDER FOR SLOPES EXCEEDING 4: 1 r.. l' SHOULDER FOR 2'-8' VARIABLE WlDTil SLOPES EXCEEDING 4: I SECTIOND-D OFFSITE PUBLIC CITY WIDE TYPICAL SECTION . TRAIL IMPROVEMENTS TO BE INSTALLED BY MASTER DEVELOPER PER CT 99-04 NTS NTS H&A 3i5!2007 CT 05-13/CP 05-12 ------------------------------/\ /\ EXCLUSIVE USE AREA CALCULATIONS EXCLUSIVE USE AREA NO. EXCLUSIVE USE AREA (SF) 1 5,429 : 2 5,246 ~--\ I /LOT LINE 3 5,369 4 6,255 I 5 5,573 6 5,102 II ~ PROPOSED EARTHEN 7 4,915 8 4,651 9 4,450 rV SWALE 1% MIN. 10 4,207 11 3,862 " II "' , IV , , • < • , , 1\ < I I / - SIDEwALK / CURB/ TYPICAL DRAINAGE DETAIL NOT TO SCALE T yP STREU LIGHT ICAL ''\, N'LY AND w'LY f-rl s'LY AND £'L Y R/W 56' PUBLIC UTILITY EASEMENT R/W 28' 28' J' 10' 18' 18' 10' J' MUV. II MIN. 6" 5' 5' ~ 5' 5' 6" -? \ ' ~\;i-0 -::;,.'/ \ lIllY" ~~ f-TYPICAL 'k j) ,~ 2% nRE HYDRANT AIII\ ~ -n ....2!L (7 j.. 11// "/1. -'. -'" ~ '--:"-l r" 2% % r I IIIJI~ .-_~_,_ /III %..? ,,~ <a" ~ -/ .... :.:.::: .... ::." ~'" ~ ... .... . ... ~ ...., . <a ~~ "}:~\\\\7 _1/11_"1111 1111 ~ • i'111..\,IH III. "':::"'0-?' ~ ::; ~ CONCRETE '" \ ""v l, '.' AL DRY UTILITY TYPIC TRENCH ( SDG&E, PHONE, 1u c<-$8" WA TER MAIN WALK (TYP '" ~_ "'"\ '-OW,,"" W'" ICAL) CATII, ETC) I'-A AND GUTTER ICAl DRY UTILITY TYP BOXES , VAUL TS, ACCESS fC \ STORM (TYPICAL) \... ]/DRAIN* FACE OF DWELLING HANDHOLE, ETC. A.C. PAVEMENT 13' 11' AND BASE NOT TO SCALE ON PLAN * PORTIONS OF STORM DRAIN IN PRIVA TE DRIVE 'A' AND STORM DRAIN IN PRIVATE DRIVES 'B' AND 'c' SHALL BE PUBLIC. PORTIONS OF STORM DRAIN IN PRIVATE DRIVE 'A' SHALL BE PRiVA TE AND A 20' PRiVA TE STORM DRAIN EASEMENT SHALL BE PROVIDED TO THE LA. COSTA RIDGE HOA. PROPERTY LINE (5' MIN. *) 3'*/5' PRIVATE LOCAL DRIVES PRIVATE STREETS '~", "B" AND "G" "LIVABLE STREET DESIGN" NTS LOCAL STREET -DES/GN SPEED: 25 MPH ACTUAL STRUCTURAL SECTION TO 8E DETERMINED BASED ON THE "Ro VALUE TEST, APPROVED BY THE CITY ENGINEER PROPERlY LINE (5' MIN_ *) FACE OF DWELLING ,.---FA CE OF DWELLING 3'* 5' 3' MIN. 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 RES, SUBTOTAL RES. AVERAGE LOT AREA RES. MAX LOT AREA RES. MIN LOT AREA APPROVED- TIllS IS TIIB APPROVED TENTATIVE MAP/s1TB PLAN PBR CONDmON NO. f, OF PLANNING COMMISSION RESOLUTION N lH "I fLliI... tuft I EnJin=rina Dept. • Date F Planning Dept. _ Date P OPERTY LINE (FENCE) 3' MIN. 3,843 3,930 4,220 4,076 3,870 4,280 4,466 3,999. 3,961 3,870 3,870 3,982 4,571 4,178 3,960 3,710 5,284 4,948 4,551 4,494 4,868 4,170 3,870 3,870 4,141 . 4,143 6,398 3,911 4,360 4,065 4,573 5,558 4,858 4,155 4,008 5,272 4,249 4,491 5,004 3,828 4,805 4,229. 237,948 4,490 6,398 . 3,710 PROPOSED PAD v-~\~$. \1\\ === \\\\'=--\\\\ r;;.\ @"-~'i-'" ?" 5'* /7' FACE OF DWELLING 0,,,-0 f;;?-- ;$:' ~ VARIABLE SLOPE (2: 1 MAX.) RETAINING WALL 2' 3" 5' RETAINING WALL *ALLOWED PER PACIFIC SOILS INC. SOILS LETTER DATED . JAN-16-06. SEE SHEET 1 GENERAL DESIGN-SITE PLAN NOTE # 18. DRAINAGE SWALE DETAIL NOT TO SCALE PCR TYPICAL CORNER LOT SIGHT DISTANCE TRIANGLE VEGETA TlON, SLOPE & ETC.) SIGHT DISTANCE SETBACK DRAINAGE SWALE DETAIL RETAINING WALL REQLlIRED NOT TO SCALE PREPARED BY: HUNSAKER & ASSOCIA TIS SAN DIEGO, INC PLANNING 10179 Huennekens Street ENGINEERING San Diego, Ca 92121 SURVEYING PH(856)558-4500' fX(658)556-1414 PROPOSED PAD 11\\=== \\\~\\\ "' -.' ' '"" PROPERTY LINE -SlOE YARD - PLANTABLE AREA DETAIL NTS . . -• .;f SHEET 2 OF SLOPE EDGE BUILDING SETBACK INDEX SCALE:: /" = 40' 11.67' 20.33' H-24.6' 0.7 1 1 1 1 1 TOP OF SLOPE 1[11/ SETBACK ~ LINE OF SIGHT 'v LOT 16 1 PLAN 2 1 SPANISH / 1 1 /---18.8' ACTUAL --1/ LOT 16 SETBACK* TOP OF SLOPE SETBACK SECTION "A"-TYPICAL SCALE: ,.' = 10' NOTE: AS LONG AS A 17.2' MIN. OISTANCE IS MAINTAINED, THE TOP OF SLOPE SETBACK REQUIREMENTS ARE MET, H-22.3' 0.7 1 TOP OF SLOPE 117 1 1 1 SETBACK ~ It', LINE OF SIGHT 'v LOT 11 1 PLAN 2R 1 SPANISH 1--17.5' ACTUAL--f LOT 11 SETBACK* TOP OF SLOPE SETBACK SECTION "B"-TYPICAL SCALE: 1" -1 0' NOTE: AS LONG AS A 15.6' MIN. DISTANCE IS MAINTAINED, THE TOP OF SLOPE SETBACK REQUIREMENTS ARE MET. I SLOPE EDGE BUILDING SETBACK SCALf: I" = 10' 17.67' 20.33' 19.67' 19.33' ARCHITECTURAL PLANE DETAIL SCALE: 1" = 20' / lI&A 3!512007 / I / / 30' ACP RECLAIMED WA7FlI-- PER DWG ! 2D0-2 " "-"-'- CT 05-13/CP 05-12 RECYCLED WATER METERflVG STATlDN ___ --\ \ LOT 7 1.4 AC PROPOSED REClAIMED WATER MET£~~_ AND lATERAL (TIE TO EXISTING) I I / I 8' PVC REClAIMED WAW/---:' PER OWG ! 397-30 ABANDONED 12" ACP !.'fC!:41MED--,!. WATER PER OWG ! 200-2 I I I ./ j ! , I I I I I l- I ! , .' Q:- OT7 1.4AC .... '\ '\ \ \ \ \ \ \\ PER DWG! 368-28 / / / / / / / ./ ./ ./ / / ./ ./ / ./ ./ ./ ./ / I , I \ / \,/ /\ ./ ' / \ ) I I I I J I I I I I I I I / / / / / / / / / / / / / / / 1/11 I I I I I I I I II I I II I I I I I I \ I I I \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ ~-,ro' ACP REClAIMED WATER PER DWG ! 358-2B ~-12'" ACP RECLAIMED WATER AS SHOWN ON DWG ! 358-2B __ r---PORTION OF RSF RD PREVlOUSL Y DEDICATED PER FINAL MAP 14838 \ \ \ \ \ \ \ \ \ \ \ \ \" \ \ \ \ \ \ \ / / / / / . / / ( / I I 60 0 60 12.0 ~~~~180 ~~~i~lIiBIIiil= i APPROVED 1HfS IS TIlil APPROV!ID TilI'i.TATI,VE'MAPISI'I'If PLAN PI*CONDmON NO. =~ b,;::--_ 9~~5~OOIIIrG COMMISSION RESOLUTION "71~'--'-'~' SCALE I' -60' I I I I I I I , LOTTING DETAIL SCALE: 1" -60' PREPARED BY: •: . , i ~.""",,~ .... =~ HUNSAKER & ASSOCIATES SAN DIEGO, INC. PLANNING 10179 Huennekens Street ENGINEERINC San Diego, Ca 92121 SURVEYING PH(858)55B4500· fX(858)55B·1414 TENTATIVE MAP/CONDOMINIUM PERMIT LA COSTA RIDGE NEIGHBORHOOD 2.6 VILLAGES OF LA COSTA City Of Carlsbad, California SHEET 3 OF 6 R,\0459\&Pln\ TM Sht 3.dwgClJul-12-2006,08,58 <0 ::! I -~ ci '" ci '" , \ ';, I • I I ./ " I . ( , : i / . , :;! c I, ,1\ , ' , " II 11 " I r--} ,I 1/1/ 4-1-/- ~. ""'''l RETAINING WALL /I = 1/1/ -11/1 1...--1-1111 ~ 48' 1 ~ <ci 1 _____ I"- 36'STORM~ DRAIN V SECTIONE-E PROPOSED WALL AND EXISTING STORM DRAIN . ! r--J I , i ! / / 1 ";' -" '" "---, ' ..... ----,,/ --c· " \ ,I \."-... C, , , PROPOSED ANr/ ; " ~~:':7'--' ~ ,'''. '. ,; 8" PVC ./-RER DWG ~4 I NTS ., i \ \ >, ~ , ,~ // \. // / j); WATI:R,j,IETI:RING , . , L. 4 1~ PER 36" RCP ~Th~, PER nWI7(c·d/ LU,U-. " RCf;' STORM,n~Wfi~=:--"'tM--'i>:; -owe # 200-2 : I . ABANDONED \122~" :tr:J1[~£j~~V-f; WATER\PER ~ / ! I i ,:, " " '. ',-, ' \ , " \ , , / ! , i , , ' , , , , . !! I , 1 } I ;: , ' ! : , , , , , . , , , , , . /' EXISTING 16" ,}:"IWn?JL, __ -;7m:!II:~ ./ PER DWG # 2054-2 I' / I!! I f r ~ , i .. ! I / ~ , I J \ , ' I! l ,I \ ",; 24" RCP STORM '. 'I' I RIP-RAP PER /! r I r~ ~E,~EMOVEP/ STORM DRAIN INLET PER ~""'---r~-~".-, .. / 200.-2 TO BE REMOVED, i ! / ' ... WITH CURB, AND PIPE IN PLACE (SLURRY FILL) , , " 24" Rep STORM DR~/N -+--<:1.1. PER DWG # 200.-2 I \ ABANDo.NED IN PLAGE ,(SLURRY FILL)' SEE SHEET 5 NOTE: H&A 3!5!2007 CT 05-13/CP 05-12 ---w- ! " ACP RECLAIMED WATER DWG # 368-2B ~~# 368-2B , ! /1 ,/ I ". --.-~-- ! I / ! x ", I .Y-R--,F;6'·"-I<r:'A STORM DRAIN-. . rum' 'I.-I3/V7)WG # Jo'8.~2B I ! / / -"-- / '\ :" /""---J l ". . , ., '/ . ,~ , \ ',' ')" " I' ., ... ~, ,.5 / !' ..... ~ . ,,\\' ,,,,- 54" RCP STORM DRAIN I ."- , / x , AS SHOWN ON DWe # 368-2B~" \," 1 \ \,. .',.' \' 1" ---0'-- \ ~ \ \ • ' ~, r I' ~~72" ACP RECLAIMED WATER AS SHOWN ON DWG # 368-28 i~~+1\:'-EXISTING SEWER MH #4 £I 325.4 PER SMCWD DWG NO. 52o.7-3A , . , ,AI--'M-lM--CONNECT TO EXISTING 8" VCP SEWER ! / " y, ,/ , / \",' \\ ~,/" ,,/ --;-i , 84" RCP STORM DRAIN _ " '7'/\/ ./ " ',AS SHOWN ON DWG # 368-2B>,>'}\ ;:" .!"'C' :,-.'.-< -,"~..--"". , \.\\---"--iPROPo.SED 30' PUBLIC EASEMENT Fo.R SEWER AND STORM DRAIN \.\">'~ -,\./~ \\\~<'"-", '\\'.~'.' I !.k-''J.-\\,'' ____ ~ 36" RCP STORM DRAIN., i ' ;"-", / ~~~~V AS SHo.WN ON DWG # 368-28 '</ .. <. o i 84" WING TYPE HEADWALL & /, " , MAJOR DRAINAGE CHANNEL / /\ \ , .' "AS SHOWN ON DWG # 368-2B,/·. 40 ! SCALE 1'~ 40' . ! " ,- ! " " / i~~Q~~~tf~~[~\~ -WIDE TRAIL, PRo.Po.SED IMPROVEMENTS TO. CONNECT TO EXISTING RANCHO. SANTA '4il~I0Y\W?Ji;il FE ROAD TRAIL ( /-,' !~~~~~~~~l~~\~~~" WING TYPE HEADWALL &/ '/'-'" HUNSAKER & ASSOCIATES SAN Of EGO, INC. PLANNING 10179 Huennekens Street ENGINEERING San Diego, Ca 92121 FOR LGTTlNG INFO.. SEE SHEET 2 LGTTlNG DETAIL SURVEYING PH(858)5S84S00· FX(858)SSa.1414 MlNo.R DRAINAGE CHANNEL, ' \ / AS SHOWN ON DWG # 368-2B"" TENTATIVE MAP/CONDOMINIUM PERMIT LA COSTA RIDGE NEIGHBORHOOD 2.6 VILLAGES OF LA COSTA City Of Carlsbad, California 120 i .-. SHEET 4 OF 6 R,\Q459\J>Pln\ TM Sht 4.clwg[]Jut-12-20Q6,09,Q4 "' _____ • _. ___ .~ ". ________ ~ ___ • _________ • ______ • __________ ~~_ , __ .I, '" 1 ' , 1 ( , , / J I " ,- ! ! " ' / ! , ' , ; , / " I , 1 I I 1 , I I j i , I d , I 1 , I i I ' I I \ / / EXISTING 16" SHVFR+'-- PER DWG # 2054-2 ,"· ... "rll;',1.1 J I : / 1 \ i 24" RCP STORM DRAIN AND --", J 'I 'I RIP-RAP PER owe # 200-2 , " ) TO BE REMOVED <-, -!i-,,_ fl I \ I ,",jiliN I • " ~ / !, STORM' DRAIN INLET PER Dwe # 200-2 TO BE REMOVED, REPLACED _' WITH CURB, AND PIPE ABANDONED IN PLACE (SLURRY FILL) I J IVIA.lPtJOtJ1~tRY 24" RCP STORM DRAIN -f--(f;( /---,-----+-,j". '--rf--~~,---__ J owe # 200-2 ABANDONED IN PLACE \(SLURRY FILL) '" ~,\ \ , \ \ , J , ' I,' / / , ; , ; J , i / / JK 12" STEEL WATER ~A''N'-TtfflmI1LJ1-ILJi.J r-c' __ ,,:P_'£,7.R~ __ 7'q .we '# 200'-2' PROPOSED PRIVATE 48" STORM WITHIN 20' PRIVATE MAINTAINED BY LC 2.6 HOA '-, . " , " i ' "-, EXISTING FIRE HYDRANT PER owe # 200-2 TO BE RELOCATED , , , '-,[(ROPOSED PlRtJ ,H)<'()R)IY\J7748@r;t~f,4!/-t:-~~{;J \ / / 'j_ -I I ! EXISTING 48" STORM PER DWG # 397-3, I , I ' "STREd LIGHT :.~~~~~~ PER DWG # 200-i' f )\ // ,~~~~~~~ ,18" RCP STORM DRAIN ;<; PER DWG # 397-3 -\ / . ~ / ' -, " \ '" [XISTING 8" SEWER~~~,*~~, PER DWe # 397-3 1; , I f! f / I / 397-3 . :'\~EAtidw' LcI""lL ..... ."'-. /:/rREA TMsNT I I , , " / ,J • , , " , J ; " \ , ' ; I , , -------,,---- --~-----------r-----_-----~_, __ ~--,__ "'"" ~ , I \ \ , J ! , I /' SEE SHEET 4 , , J ! r j I \ , J ! " f ! . \ 1 I , i I I ,I I / , ! / / / .' I I / / I , I I I ! / I ! f / / I ! / J , , , ; ; , I I , , • I , / / '/ / / / , " I , 1 / ! 1/ / '~ \ I '~ " "." / CT 05-13/CP 05-12 llq 'I \ '\ d J N 54" RCP STORM DRAIN J AS SHOWN ON Dwe # 368-28 ;' 1\' \ /' \ . ' \, , "\ , ' " , --4-\J'-12" ACP RECLAIMED WATER ' '", AS SHOWN ON owe # 368-28 v /~ x / ! / / / " ! / J '~..!.:J ,\Yc,,--84" RCP STORM VI<AI/N </>c"~,~ AS SHOWN ON DWG # 368-28 / / / v- J A \'-\\--+-1~ EXISTING SEWER MH #4 £/ 325,4 PER SMCWD DWG NO, 5207-3A TO EXISTING VCP SEWER , I ' 3.1.' 5 / / ~c, IJLf" RCP STORM DRAIN , I ,-;~~, / ,AS SHOWN ON owe I 368-28' /',' ~; \.v" / .'--\./ ~-4F)ROPO~)ED 30' ?UBUC EASEMENT FOR SEWER AND STCRM DRAIN J '\\':-\ \' ~"'.-" J <, ' ~ ::::t1~ __ ~-36" RCP STORM DRAIN, I AS SHOWN ON DWG I 368-28 'N' \7 84" WING TYPE HEADWALL & MAJOR DRAINAGE CHANNEL 3AS SHOWN ON DWG # 368-28 , J / ~~~;~~~~~~1~\-~~;~~~ TRAIL, PROPOSED IMPROVEMENTS TO CONNECT TO EXISTING RANCHO SANTA FE ROAD TRAIL I / , , / ~_ 1 / , ! J ! , ~/- \ \, .-"'Tf~~rF~1i~ X~u~~~~~ttl~:~~~" WING TYPE HEADWALL & / Jl MINOR DRAINAGE CHANNEL", " "AS SHOWN ON DWG # 368-28>~', / \ ~f\llt\4\\~~-2~~~~~;~ \ ----\ " \ "' \,X\NI\'PI~[\\ PROPOSED "cfrY -W/[)?~ '\ : .' "/ TRAIL & EASEMENT \ " ': , ' " \ ------\ '\, \\---'tl~t-ltt-f--~~~::::>r\\-'-PROP. 'F -TYPE CATCH BASIN \' ' ", ~ /~ ,j \~N+::::A-4~~----'fr~~~-',' PROP, INLET FILTER UNDER SIDE'fALK DRAIN IPRIVATELY MAINTAIf:JED}) , / M..l.:,~W:'\-~~4~rrrPROP, STORM WATER TREATMENT UNIT (f,RlvATELY MAINTAINEDf'!~ j // -- I \ \ :. , -\~ / , ..... , " ----~,\ \, // ::t.(.7 100-YEAR FLOODPLAIN "";, '.' f 7/ 2/Mi'iS~,-f' PER FLOOD INSURANCE \; :, ' ~ ,",' " (/ ,/, / DATE HAp /cZR'.J\· \ \.\' '" , ' f f--,.----=--_--. ___ fV1/1 'WI"! {n IVIJ \, \.'''\" '."'~;' ;' f 1/ / PANEL 1051 OF 2375 ' \ ; ~~ '",'-: ,! " ~/ -_:: \. -, t ... :::' -_' ,,-~-~---__ , V" '-'\ ~~~~~~ i-~-=1~~ -~:-~~_:-- '3& 5 >.. \, ',-~---.. \, \, \, THIS IS THEA~:~~I~g8:~~~~t~~~~; PLAN PER CONDITION NO, CO~~MJi'SlcrN RBSOWI;jON "'Jr --t!!L!~-'/ ! I ' \ I'-t-_-;~/ ~~:::IPROPOSED 100 ~R FLOOD UMITS L' \ '-....... EXISTING 100 Y&IR FLOOD LIMITS 100-YW? FLOODPlAIN PER FLOOD INSURANCE RATE MAP (RRM) PANEL 10!)1 OF 2375 / I / I / I I / / I / I I I 1 ) I , I l.... '-. \ \ \ , \ , " 1 "= 60' PREPARED BY: TENTATIVE MAP/CONDOMINIUM PERMIT SHEET •' ; , . , , j , i v~_~"",,' HUNSAKER & ASSOCIATES SAN DIECO, INC LA COSTA RIDGE NEIGHBORHOOD 2.6 5 OF /_, /-R/7~--/' , "c / / / /' / /' EN~~::~~ !:~:~:~::'treet VI LLA G E S 0 F LA CO ST A ~~~ ____ ~~~~~ .. ~ .. ~~~~~~~~~? __ ~~~~//.'~~;~~_"_"_'-__ J3~~3 __ ~~::~~~~~--~~~~~~~-~'-:":'~-~~~-~-:-::~/~:' ________ ~~ ______ ~~~-'~~.i~ __ ~~~N~O~T.:E~· ~F~O:R_L~O~T:T.~IN~G~/N~F~O~'':S[~E~S:H~[~E~T~2~L~O~T~n~N~G~D:[~TA~/~L __ J. __ :su:~:~:ING~~:(:85B:)s:5~:45:oo~,~:(~:8:)55:~:~~4.1 __________ ~C~it~y~()~f~<:~a:r~l~s~b~a~d~,~c~a~l~if;O~r!n~i~a~~ __ ~ __ ~~~E3~ __ J: , ! / / , , / ./ / / '-" / , R \0459\8.Pln' TM Sht 5,dwgll.Jul-12-2006'09119 ll&A 3!5j20l17 // / / / RIGHTS ~..o;-=..~--.-::l=-,c--_-;:- 'J)~ ~ .r) r' LO, I i I r ( ./ , ) , li:~~:..---~~7~/?'--!--RfLlNQUISHMENT OF ABUTTE/?,'S RIGHTS OF ACCESS: IN ACCO(?DANCE WITH LA I COSTA RIDGE / / / ./ ,/ /' . MAP NO' 14838 \ REVESTMENr OF ieCESS RIGHTS REQUIRED AI' DRIVEWAY LOCA TIONS , '"" '> . ) \ \ / \ , \ ! \ / / , , , CT 05-13/CP 05-12 \ ~ r _ ______ --t- A (l:~~~);;~~~;f~~ FOR ROAD TO AETNA OAPITAL COMPANY, A CALIFORNIA r DOCUM[NT 8EtI~0r.'Dtz,)-J<~b,? 11, 1980 AS FlLf NO 80-217365, O.R " I~~~~t~~~ ~~J~~~g:~~i;r.~O;jS4~N DIEGO COUNTY DRAINAGE MAINTENANCE D/.J1,'!U~>I'ENl 1981 AS FILE NO 81-117297, OR. ON PLAN ~~~~~~;'p1:~~~~~T~0 SAN MARCOS COUNTY WATER DISTRICT RECORDED JULY 29, 1958, AS DOCUMENT REMAIN C~(~i~·1~~~1~~;Z;~~f9fCf.0UNTY OF SAN DIEGO BY DOCUMENT r, 0 R. PORTION TO BE VACATED '~Jf,IVFY 454) GRANTED TO THE COUNTY OF SAN BY DOCUMENT RECORDED APRIL 7, 1966 FOR PUBLIC TRAIL DEDICATED ON MAP 14838. BE VACATED AND RELOCA TED. ON MAP 14838 TO THE CITY OF CARLSBAD TO BE .~'$;.~~::J;e~~1J!~tt:'·~~f HIGHWAY GRANTED TO CITY OF CARLSBAD BY DOCUMENT. FILE NO. 81-126304, OR. TO REMAIN I (. ~~!~~~~~~~~~~~~~~~ AND HIGHWAY GRANTED TO CITY OF CARLSBAD BY DOCUMENT It AS HLE NO 81-126307. 0 R. TO REMAIN --- l \ / / '" -~,-\ C l-/'"l .k '-~-.. \ ... NUMBER Cl C2 C3 \\ C4 C5 NUMBER L1 J" L2 ~ L3 , \: /. / ... / , L4 L5 , , \ . DELTA RADIUS LENGTH 28'13'49" 20.00 9.85 62'13'21 " 3350 36.38 90'00'24" 25.00 39.27 31'47'07" 51800 287.36 07'19'48" 470.00 60.13 BEARING DISTANCE N 66'05'00"W(R) 60.00' N 35'2$'54 ''W 55.00' N 52'28'36''W(R) 12.00' . N 23'05'37''W 30.45' N 25"56'11 ''W 60.00' ---!'. I PREPARED BY: TENTATIVE MAP/CONDOMINIUM PERMIT HUNSAKER & ASSOCIATES SAN D!ECo, INC LA COSTA RIDGE NEIGHBORHOOD 2.6 SHEET 6 OF EN~~;:~~ ~:~~;::~;;2~treet VI LLA G ES 0 F LA CO ST A 6 .. __________________________________________________________ ~ ______________________________________________________________________________________________________________________ .1 __ ~S:UR:vm:N:G.:~:~:m5:5~:~:OO~.~:(B:~:)~:~:~4~L. ________ ~C~it~y~()~f~c~a:r~l~s~b:a~d~,~c:a~l~if~o~r~n~i!a~ ________ .J __ 2:~.J~ R \0459\&Pln\TM Sht 6.dwg[]Jul-12-2006 09 30 ll&A 3 5 2(107 > ~. ~~ ))) ~/ -'u X ~ -t ~ x ~ ~ -X / / 8~.0~~~80~~~1l60~~~ ~ I Ii L..-_"7"'"" __ ~S:..:;CALE 1'-80' ....-___ ---.J USH HUNSAKER & ASSOCIATES SAN DIEGO. INC PLANNING 101i'"J Huemekens Street ENQNEERlNG San Diego. Ca 92121 SUlVEYlNC PH{8S8)558-4500-FX(858)558-1414 -" -" '- / -" -" -" -" LIM :IT OF GRADING , SCALE 1:20 EXISTING FIRM EXHIBIT FOR LA COSTA RIDGE NEIGHBORHOOD 2.6 CITY OF CARLSBAD, CAUFORNIA SHE ET 1 OF 1 R'\04S9\8.Hyd\04S9$H10-EX-FIRM.dwg[ 208SlM(lr-OS-2007,17,37 <0 .., -I iii ..... -... ci ;<