HomeMy WebLinkAboutCT 10-01; SEA BREEZE VILLAS; GRADING PLAN REVIEW; 2011-05-24a
L
w
U
z
STRATA-TECH,INC. 714-521-5611
56242799
EocaNBuLTANTa FAX 714-521-2552
7372 Walnut Avenue, Unit FBuena Park, California 90620
May 24, 2011
Tony Sfredo
21 Wooderest
Irvine, California, 92603
IYN 0 2
0,- PA R TMEN I
W.O. 262310
Subject: Grading Plan Review and Groundwater
Statement: 391 Tamarack Avenue, Carlsbad,
California.
Gentlemen:
Pursuant to your requesi; STRATATECH, Inc. has reviewed the grading plan for the site that has
been prepared by DMS consultants Drawing No 471 3a..
These plans are in conformance with the remmendations of the Geotechnical report for this site.
The stormwater infiltration will consist of permeable pavements. The pavements will be located at
finish grade approximately 1 foot above the existing grade. An exploratory boring drilled on
August 3, 2010 to 12-feet below existing grade revealed dry sand, and a lack of groundwater and
confirms that the proposed groundwater infiltration system will be located at least 10-feet above the
groundwater table.
We appreciate this opportunity to be of service to you.
Respectfully submitted:
STRATA-TECH, Inc.
wp. it
Larry Finley
RCE 46606
Roland Acuia, PG
Principal