HomeMy WebLinkAboutCT 11-02; LA COSTA VISTA; AS-BUILT COMPACTION REPORT; 2016-02-20-I5TRA
GEDCO
310.968.2999,
HjNaH1
Nrs
stratatech@yahoo. corn
TA-TED
N.5ULTA
February 20, 2016 W.O. 263810
Tony Sfreddo
D.S. Products, Inc.
24 Amberleaf
Irvine, California, 92614
Subject: Final As-Built Compaction Report, Multi
Family Residential Development, 7500
Jerez Court, Carlsbad, California
Reference:
STRATA-TECH, INC., Geotechnical Engineering Investigation of Proposed Multi Family
Residential Development, 391 Tamarack Avenue, Carlsbad, California., Dated October 4, 2011
Gentlemen:
Submitted herewith is the Final As-Built Compaction Report for the subject site. The grading
operation was conducted between April 7, 2014, and July 21, 2015, the building installation and
driveways were iconstructed between November 2014 and September, 2015 utilizing the
referenced preliminary report. Observations of the grading, foundations and driveway subgrades
were provided by" STRATA-TECH, Inc.
PLACEMENT OF STRUCTURAL FILL
Compacted fill was placed on the subject site to provide adequate support for the proposed 2-
story Multi Family Residential Development
OBSERVATIONS DURING GRADING
Preparation for placement of a compacted fill included overexcavation to approximately 3 feet
below existing grade, and 5-feet beyond the building foundation to provide a minimum of 2-foot of
compacted fill under the footings of the proposed building. Prior to placement of fill, the bottom
was made level, scarified, watered and tamped smooth.
1920 Pacific Avenue, Unit 16060, Long Beach California, CA 90806
STRATA-T,E C H ,IN C.
6 ED C ON S U L T A N T S
D.S. Products, Inc. 2 W.O.263810
As-Built Compaction Report February 20, 2016
Subsequent fills were placed in 6 to 8 inch loose lifts and compacted to a minimum of 90
percent. The pads were raised approximately 3 feet in the back to allow for drainage toward
Jerez court.
Driveway Construction
The area north of the building was fine graded for the PCC Paved Driveway over storm water
infiltration systemLand parking. /
Approximate locations of utilities are.
Foundations
Foundations were excavated per plan and penetrate the bearing soils a min of 24"
Backfill
Interior and exterior utility trenches were backfilled and compacted and shown on Plate A.
TESTING
Maximum density optimum moisture relationship determinations were performed for each soil
type encountered during grading operations. Test results were as follows:
Laboratory Standard: (ASTM: D-1557-91)
4 inch dia. mold; 1/30 cu.ft.vol.;
5 layers-25 blows per layer;
10 lb. hammer dropped 18 inches
Soil Tpc Classification Optimum Moisture % Max.Dry Density; lbs/ft3
Light Brown Fine clayey 12 128.0 Sand
Import, Brown clay Sand 10 132.0 w/rockchips
Compaction tests were performed a minimum of every 2 feet and/or 500 cubic yards of compacted
fill soils placed. These tests were performed in accordance with ASTM: D-2922-91 (nuclear
gauge) or ASTM:D-1557-04 (sand cone) test methods. The test results are summarized in Table I.
The approximate test locations are shown on Plate A.
Areas not tested 'iere probed to show adequate compaction.
STRATA-TECH,INC.
GE 0 C ON S U LTA NT S
D.S. Products, Inc. 3 W.O.263810
As-Built Compaction Report February 20, 2016
REGULATORY COMPLIANCE
All cuts, fills or processing of original ground under the purview of this report have been
completed under the observation of and with selective testing by STRATA-TECH, Inc., and found
to be in compliance with the Grading Code of the City of Carlsbad. The completed work has been
observed by STRATA-TECH, Inc., and is considered adequate for the development. Our findings
were made and recommendations prepared in accordance with generally accepted professional
engineering practices, and no further warranty is implied nor made.
This report is subject to review by the controlling authorities for this project.
We appreciate this opportunity to be of service to you..
Respectfully submitted:
STRATA-TECH; Inc.
Roland Acuña Larry Finley
President RCE 46606
Enclosures: Compaction Test Results
Plate A - Compaction Test Map
C.
9TPATATEOHHNC.
ECONULTANTS
310. 968. 2999 stratatech(ED-yahoo.com
COMPACTION TEST RESULTS
Test
No. Location
Below
Proposed
Grade (ft)
Moisture
Content
Dry Unit
Weight Soil
Type (Lbs/fl3 )
°oRelative
Comaction p !)ate
I Building Pad 5 12.3 116.9 I 9% 4/7/14
2 Building Pad, 3 11.8 116.7 I 90%
3 Building Pad. 5 12.8 116.9 I 90% 4/8/14
4 Building Pad 3 12.1 117.3 I 91%
Building Pad 2 12.2 1 117.6 I 1 91%
6 Building Pad 2.5 12.4 118.1 I 90% 4/9/14
7 Building Pad 2 12.1 117.9 I 90%
8 Building Pad 3 11.5 118.3 91%
9 Building Pad 2 11.6 118.5 91%
10 Building Pad PG ,. . 10.2 119.8 I 91% 4/11/14
ii Building Pad PG 10.3 119.6 I 91%
12 Building Pad 3 12.1 120.2 II 4/17/14
13 Building Pad 2.5 12.1 119.3 II 92%
14 Building Pad i 13.5 122.2 H
15 Building Pad 1 9.9 122.7 11 93%
16 Building Pad PG 10.1 123.5 11 4/25/14
17 Building pad. PG 10.2 122.2 11 92%
18 Sewer 4 9.7 119.8 11 92%
19 Sewer 2 8.9 120.5 92 7/11/14
20 Electric . 2 8.6 121.0 91
21 Building Pad* P.G 8.2 121.4 92% 9/8/14
22 Building Pad * P.G 8.5 121.5 II 92%
PG= Pad Grade
*retest
1920 Pacific Avenue, Unit 16060, Long Beach California, CA 90806