October 5, 2015
S tk€o
tLCOQT
695 Rftiss 5q
Suite C
5Dege.CA 92821
Tel: 85&5373999
Fav 858531.3990
OluNGE COLNfl
CoRroRiTi BRICH
2992 E La Palma Avenue
Suite
Anaheim, CA 92806
Tel: 714.632,2999
Fax: 714.6322914
IMAND EMIIru
14467 Meridian Parkway
Building 2A
RivcI5ideCA 92518
Tel: 951.653.4999
Fa 951.653.4666
OC/.VIL,o EMPIRE
DISPTCII
800,491.2990
Grand Pacific Resorts, Inc. MTGL Project No: 1916A09
5900 Pasteur Court, Suite 200 MTGL Log No: 15-2320
Carlsbad, California 92008
Attention: Mr. Houston Arnold
Subject: BUILDING PAD RE-CERTIFICATION - VILLA 60
Marbrisa Resorts
Carlsbad, California
Dear Mr. Arnold:
Per your request, we have prepared this letter to certify that remedial grading for Villa
60 building pad at the Marbrisa Resorts was accomplished in general accordance with
the approved plans, specifications and geotechnical investigation.
Remedial grading consisted of over-excavation of five feet of soil from finished pad
elevation. The excavated soils were then moisture conditioned and compacted to a
minimum of 95 percent of the maximum dry density as determined by ASTM D 1557.
We observed grading at the site from July 1 to July 11, 2014.
Due to the time elapsed from original grading the top two feet of finished grade soils
were re-processed by excavating, moisture conditioning, and compacting to 95
percent. We observed the re-grading of the pad on September 28 and 29, 2015.
Based on our observations and the results of our tests the building pad construction
complies with the project approved documents. We appreciate this opportunity to be of
continued service to you. Should you have any questions regarding the information
contained herein, please contact us at your earliest convenience.
INDlO
44917 Golf Center Pkwy
Suite I
Indio, CA 92201
Tel: 760.342.4677
Fax: 760J42.4525
S Dwco fllsp,vrcu
888.844.5060
www.mtglinc.com
Respectfully submitted,
MTGL, Inc.
Sam E. Valdez, RCE 56226, RGE 2813
Vice President I Chief Engineering