FINAL CLEARANCE REPORT ON SOIL CONDITIONS
CARLSBAD TRACT 72-2 - UNIT 3 /
CARLSBAD, CALIFORNIA
FOR
PACIFIC SCENE, INC.
2032 GARNET AVENUE
SAN DIEGO, CALIFORNIA
JUNE 6, 1973
JOB NO. 71-105
SlOlO
.5.61 SOIL AND HATERIAL TESTING LABORATORY
car Ueal)tY #¶cl”YIv. IMrn.
- SOILANDMA~RIAL~S~NG LABORATORY
OF NORTH COUNTY, INC. -
42 3 HALE AVE. - ESCDNDIDO, CALIF. 92025 - 6 June 1973 EBCONDIDO - 746-2333
,-
-
Pacific Scene Inc.
2032 Garnet Avenue
San Diego, California 92109
Re: Job No. 71-105
Carlsbad Tract 72-2, Unit 3 Altamira lpi-
Carlsbad, California
Subject: Final Clearance Report on Soil Conditions
Gentlemen:
This report is to cover the results of our tests and observa-
- tions concerning the site clearing and compaction of filled ground
placed on the above referenced project as shown on the enclosed
-.. Site Plan.
-. The filled ground for Carlsbad Tract 72-2, Unit 3 utas placed
between the dates of April 26, 1973 and May 23, 1973.
- The preparation of the natural ground and placing of compacted
filled ground was done in accordance with the approved recommendations
- and specifications contained in our Preliminary Soil Investigation
- Report for this project dated 26 January 1972. Please note this
project was previously called ltCampobello Planned Communitytf and
was subsequently entitled Carlsbad Tract 72-2, Altamira.
The laboratory compaction test procedures and test results for
_I the soils encountered during grading are presented on page 3. Also
--- shown on page 3 are the field density test methods. The field density
test results are listed on pages 4 thru 15.
- The approximate area of fill tested and location of the field
-
density tests are shown on the enclosed Site Plan. This Site Plan
- has been redrawn from the approved Grading Plan by Rick Engineers,
Carlsbad. Also shown is the location of a drain system to dry up
the groundwater as noted in the previously mentioned Preliminary Soil
Investigation.
-- Field density tests indicate the filled ground has been compacted
- to at least 90% of the maximum dry density.
Footings placed less than 5 feet inside the top of the slopes
- should be deepened one foot below a 13 horizontal to 1 vertical line
projected outward and downward from a point 5 feet horizontally in-
- side the top of the slopes.
- Final subbase field density tests should be taken when Lewder
Lane has been completed.
The cut portions of all parking areas should be reworked and
recompacted to at least 90% before importing base material.
Vertical retaining wall backfills should be tested to 90%
maximum dry density. We should be notified prior to placing any
backfill in this arear”“.
’ Storer- drafn ancb sewer cfftc6&1 which are in the zone of influence
- uf the brPi~dfng fkEJndationa should b8kompact8d to at least 90% of
the maximum dry density as discussed.
the critical areas are ready Par
-
It is our understanding that all the placing of filled ground . ,’
has been completed.
Respectfully submitted,
t j “,y ,’ : !;,<’ . p$5!*. cf ,’ ’ ? d *
I ^ \
>. SOIL AND MATERIAL TESTING
LABORATORY OF NORTH COUNTY, INC. -
Claude 6. Parker
- Registered Civil Engineer #18,987 Registered G8OlOgist #512
Distribution: 8 Addressee
Pe SOIL AND IKATERIAL TESTING LABORATORY or unltu nnuYw. IYfl.
-
- 1 - Laboratory Compaction Tests
Nine laboratory compaction tests were performed on the fill
- material to determine the maximum dry density and optimum moisture
content as specified by ASTM D 1557-64T (method’A). The test uses
- the minus #4 sieve soil in a 4 inch diameter 4 inch high cylinderical
- mold. The sample is formed with a 10 pound hammer falling 18 inches
for 25 blows on each of 5 layers.
- LABORATORY COMPACTION TEST
Test Soil Description Maximum Optimum - No. Dry Moisture
Density Content
(pcf) %>
--
1 Brown Fine to Medium Sand 123.0 9.4
2 Dark Brown Silty Sand 122.8 10.6 - - 3 Gray Brown Silty Fine Sand 99.9 23.8
4 Red Brown Fine to Medium Sand 129.7 9.7
5 Brown Fine to Medium Sand 130.0 10.0
6 Light Brown Fine Sand 123.1 12.1
-
-
7 Light Brown Fine to Medium Sand 131.2 9.3
8 Brown Fine to Medium Sand 133.5 6.6
9 Gray Medium Sand 115.0 16.0
Field density tests were taken at selected locations to
determine the moisture and density conditions of the fill and
backfills. The tests were performed according to ASTM 01556-64,
the Sand Cone method. The ratio of field dry density to the
laboratory maximum dry density is defined as the relative
compaction.
SOIL AND HAT'ERIAL TESTINQ LABORATORY mm L.--U mm..*.- .ti.-
FIELD DENSITY TEST RESULTS -
BUILDING PADS
- ate Test Re- Location Ht. of Field Field maXitTtUm Relative
of No.
best
Test of Test Fill Moisture Dry Dry of Pad No. Tested Content Density Density
1973 Test (Feet) (%I (pcf) (pcf) - No.
4-26
-
-
- 4-27
- 4-30
-
- -
-
5-1
-
-
-
/.
-
-
1
2
7
8
9
IO
11
12
13
14
15
16
17
18
19
20
21
22
Fill Slope Ulest of
Pad E-2
Fill Slope
u8St Of
Pad F-l
A-l
Q-4
A-3
Fill Slope Ulest of
Pad E-5
Fill Slope
u8St Of
Pad F-4
J-3
A-l
A-3
Q-4
Q-4
E-2
E-5
2.0
2.0
2.0
2.0
4.0
4.0
4.0
2.0
6.0
8.0
4.0
F.G.
6.0
8.0
Parking Area 2.0
East of
Pad E-2
E-2 10.0
Parking Area 4.0
East of
Pad E-5
F-l 6.0
16 E-2 10.0
Parking Area 6.0
East of
Pad E-2
Parking Area 8.0
East of
Pad E-5
F-4 8.0
9.9 120.5 122.8 98.1
11.7 119.7 122.8 97.5
4.7 119.3 123.0 97.0
8.1 121.3 129.7 93.5
7.5 114.0 123.0 92.4
17.6 92.6 99.9 92.7
12.3 116.2 122,B 94.6
5.8 118.9 123.0 96.6
7.5 119.3 129.7 92.0
9.3 119.5 129.7 92.1
6.4 119.0 129.7 91.8
7.5 119.5 129.7 92.1
9.9 129.3 129.7 99.7
15.6 93.7 99.9 93.8
6.4 117.2 129.7 90.4
503 116.4 129.7 89.7
7.5 126.8 133.5 95.0
5.3 117.7 123.0
5.8 116.1 123.0
8.1 122.6 129.7
125.2
117.3
133.5
129.7
95.7
94.4
94.5
93.8
90.4
SOIL AND MATERIAL TESTINO LABORATORY II u--u mm..-.- .-.a
I --
_1 Date Test Re- Location Ht. of Field Field Maximum Relative
of No. t8St of Test Fill Moisture Dry Dry Test of Pad NO. Tested Content Density Density ComKtlon 1973 Test (Feet) (%I (PCf) (PCf)
5-l -
- 5-2
/-
-
-
-
-
-
-
-
-
.-
_-
5-3
-
-
-
23
24
25
26
27
28
-29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
F-l 10.0
E-5 12.0
E-5 F.G.
E-2 F.G.
Parking Area 2.0
East of
Pad F-l
Fill slope 2.0 UJest of
Pad G-3
Fill Slope 4.0
West of
Pad G-4
F-4 12.0
F-l 14.0
Fill Slope 2.0
Ulest of
Pad D-2
xx 2.0
xx . 4.0
Parking Area '4.0
East of
Pad F-4
A-3 F.G.
A-l F.G.
Fill slope 4.0
West of
Pad D-2
Parking Area 6.0
East of
Pad F-l
Parking Area 8.0
East of
Pad F-4
xx 6.0
41 xx 6.0
Fill Slope 6.0 South of
Pad D-2
D-2 8.0
9.3 123.8 133.5 92.7
6.9 123.8 133.5 92.7
6.4 114.8 123.0 93.3
7.0 120.5 123.0 97.8
9.9 117.5 130.0 90.4
7.5 117.2 122.8 95.4
5.3 110.5 129.7 85.2
11.1 129.7 133.5 97.2
11.1 119.4 130.0 91.8
8.1 118.2 129.7 91.2
8.1 115.5 123.1 93.8
9.9 114.6 123.1 93.1
11.7 113.2 123.1 91.6
8.7 120.0 129.7 92.5
7.5 110.9 123.0 90.2
6.4 111.5 123.1 90.6
9.9 118.1 130.0 90.8
8.1 109.9 130.0 84.5
8.7 113.4 130.0 87.2
8.7 120.0 130.0 92.3
9.1 120.5 130.0 92.7
9.3 117.0 123.0 95.1
SOIL AND MATERIAL Tl3BTXNO LABOlUTORY
-
Date Test Re- Location Ht. of Field Field Maximum Relative - of No. t8St of Test Fill Moisture Dry Dry Compactior
Test of Pad No. Tested Content Density Density (%I ,- 1973 Test (Feet) (%I (PCf) (PCf) - No.
5-3
-
-
-
-
-
-
-
-5-4
-
-
-
-
-
_-- -
-
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
xx 8.0
F-l F.G.
D-2 10.0
Parking Area 8.0
East of
Pad D-2
29 Fill Slope 4.0
West of
Pad G-4
G-3 6.0
G-4 8.0
G-3 10.0
G-4 12.0
Parking Area 2.0
East of
Pad G-3
G-3 14.0
Fill Slope 2.0
West of
Pad B-2
Fill Slope 4.0
West of
Pad B-2
Fill Slope 6.0
West of
Pad B-2
Parking Area 4.0
East of
Pad G-4
Fill Slop.8 8.0
West of
Pad B-2
G-4 16.0'
G-3 18.0
B-2 IO.0
B-2 12.0
B-2 14.0
Parking Area 6.0
East of
Pad G-4
9.9 122.7 130.0 94.4
8.7 117.3 130.0 90.2
8.7 117.9 130.0 90.7
8.1 122.5 130.0 94.2
7.5 119.9 . 130.0 92.2
7.5 117.3 130.0 90.2
9.9 114.6 123.0 93.2
9.3 113.8 123.0 92.5
6.4 125.3 130.0 96.3
7.5 114.4 123.0 93.0
6.9 115.0 123.0 93.5
5.8 118.9 123.0 96.6
7.5 114.0 123.0 92.7
8.7 120.6 130.0 92.8
8.1 114.4 123.0 93.0
8.7 115.6 123.0 94.0
8.1 114.6 123.0 93.2
a.1 124.7 130.0 95.9
8.7 119.3 129.7 92.0
9.3 115.4 123.1 93.7
8.7 120.7 130.0 92.8
8.7 117.0 129.7 90.2
8OIL AND BfATERIAL TESTINO IARORATORY
Date lest Re- Location Ht. of Field Field Maximum Relative - of No. test of Test Fill floisture Dry Dry Test of Pad No. Tested Content Density Density
- 1973 Test (Feet) (%I (PCf) (PCf) - No.
5-4
-
-
-
-
-
5-5 -
-
:--
-
-
-
t.
-
.- -
-
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
Parking Area 8.0
East of
Pad H-2
C-l 16.0
8-2 18.0
Parking Area 2.0
East of
Pad O-3
Parking Area 4.0 East of
Pad O-4
Parking Area 4.0
East of
Pad N-4
Parking Area 6.0
East of
Pad O-3
Parking Area 8.0
East of
Pad O-4
Parking Area 8.0 East of
Pad N-4
Parking Area 2.0
East of
Pad 8-2
xx 10.0
xx 12.0
Parking Area 4.0
East of
Pad B-2
Parking Area12.0
East of
Pad D-2
D-2 14.0
Parking Area16.0
East of
Pad D-2
Fill Slope 2.0
Ulest of
Pad O-3
Fill Slope 4.0
West of 5
Pad O-3
8.7 126.2
6.9 119.3
6.4 121.9
6.4 124.8
9.9 113.0
9.3 120.5
8.7 114.5
6.4 122.7
9.9 120.7
9.3 122.5
9.3 121.0
9.3 122.4
8.7 123.1
9.1 118.1
8.7 120.5
9.1 120.1
21.2 91.0
22.0 92.3
SOIL AND MATERIAL TESTINO LABORATORY
133.5 94.5
123.0 96.7
123.0 99.2
133.5 93.5
123.0 91.9
130.0 92.7
123.0 93.1
133.5 91.9
130.0 92.8
133.5 91.8
130.0
129.7
133.5
93.1
94.4
92.2
130.0 90.9
130.0 92.7
131.2 91.6
99.9
99.9
91.1
92.4
Date Test Re- Location Ht. of Field Field Maximum Relative - of No. test of Test Fill Moisture Dry Dry - Test of Pad No. Tested Content
1973 Test (Feet) (%I
Density Density
(PCf) (PCf)
ComT;;tion
5-7 85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
Fill Slope 4.0
West of
Pad N-4
Parking ArealO.
East of
Pad O-3
Parking Area12.0
East of
Pad N-4
Fill Slope 6.0
West of
Pad O-3
Fill Slope 6.0
West of,
Pad O-4
Fill Slope 8.0
West of
Pad O-3
Fill Slope 8.0
west of
Pad N-4
Fill Slope 10.0
West of
Pad O-4
Fill Slope 10.0
West of
Pad O-3
Fill Slope 12.0
West of
Pad N-4
Fill Slope 14.0
West of
Pad O-3
Fill Slope 16.0
West of
Pad O-3
Fill Slope 16.0
West of
Pad N-4
Parking Area12.0
East of
Pad O-3
Parking Area14.0
East of
Pad N-4
9.3 118.4 130.0 91.1
7.5 127.3 133.5 95.4
7.5 126.9 133.5 95.1
12.3 117.7 129.7 90.7
8.7 124.3 133.5 93.1
8.1 112.5 123.0 91.5
8.7 120.6 130.0 92.8
8.1 118.2 127.7 91.2
6.4 114.8 123.0 93.3
6.9 115.0 123.0 93.5
8.7 120.0 129.7 92.5
7.5 128.8 133.5 96.5
8.7 113.1 123.1 91.9
8.7 124.5 93.3
9.3 133.0
133.5
133.5 99.6
SOXL AND MATERIAL TESTINO IAROIUTORY
Date Test Re- Location lit. of Field Field Maximum Relative - of No. test of Test Fill Moisture Dry Dry Compaction
Test of Pad No. Tested Content
-1973 Test (Feet) (%I
Density Density
(PCf) (pcf)
(%I
5-7 100
-
101
-,
102
103 -
104 -
105
_ 5-9 106
-
- 107
108
109
-
110
- 111
112
5-12 113 -
114
-
115
-
116
/ - -
117
Fill Slope 18.0
West of
Pad N-4
Fill Slope 20.0
West of
Pad O-3
Fill Slope 20.0
West of
Pad N-3
Fill Slope 22.0
West of
Pad N-4
Fill Slope 22.0 West of
Pad O-4
Fill Slope 24.0
West of
Pad N-3
Parking Area16.0
East of
Pad O-3
Fill Slope 2.4. 0
West of
Pad O-3
o-4 26.0
Fill Slope 26.0
West of
Pad N-3
o-3 28.0
N-4 28.0
o-3 30.0
N-4 32.0'
Fill Slope -1.0
West of
Pad E-5
Parking Area S.G.
East of
Pad E-5
Fill Slope -1.0
West of
Pad E-2
F-4 F.G.
8.1 111.6 123.0 90.7
8.7 124.0 133.5 92.9
9.3 112.2 123.0 91.2
7.5 117.2 129.7 90.4
8.1 118.3 129.7 91.2
6.9 116.9 129.7 90.1
11.1 119.3 129.7 92.0
11.7 129.2 133.5 96.8
6.4 130.5 133.5 97.8
8.1 119.0 129.7 91.8
9.9 125.6 131.2 95.7
7.5 125.6 133.5 94.1
8.1 119.5 129.7 92.1
6.9 130.3 133.5 97.6
7.5 111.6 122.8 90.9
6.4 132.2 133.5 99.0
5.8 123.0 90.2
5.8
110.9
113.4 129.7 87.4
SOXL AND IKAW TESTXNO LABORATORY
b Date Test no- Location Ht. of Fiold Field Maximum Relntivo
of. No, test of Test Fill Moisture Dry Dry
-Test of Pad No. Tested Content Density Density
ComT;;tion
1973 Test (Feet) (%I (PCf) (PCf)
5-12 118 Fill Slope
West of
Pad F-4
119 Fill Slope'
West of
Pad F-l
.I20 G-3
121 G-4
122 Fill Slope
a. West of
Pad G-3
123
124
125
126
127
128
129
5-14 130
131
132
133
134
Fill Slope
West of
Pad G-4
H-2
40 Parking Area
East of
Pad F-4
Parking Area
East of
Pad F-l
Parking Area
East of
Pad F-4
Parking Area
East of
Pad H-2
Parking,Area East of ,.
Pad G-3
D-2
129 Parking Area
East of
Pad G-3
128 Parking Area
East of
Pad H-2
126 Parking Area
East of
Pad F-l
127 Parking Area
East of
Pad F-4
71.0 7.5 117.1 129.7 90.3
-1.0 8.7 121.8 133.5 91.2
F.G. 6.4 117.8 130.0 90.6
F.G. 9.3 123.3 129.7 95.1
-1.0 4.2 120.9 131.2 92.0
-1.0 6.4 118.7 131.2 90.5
F.G. 6.9 107.9
8.0 8.7 117.7
83.0
90.2
S.G. 6.9 109.9 84.7
S.G. 9.3 114.2 88.0
S.G. 5.8 109.3 84.2
S.G. 7.5 109.9 84.7
F.G. 7.5 118.2
S.G. 9.9 123.1
S.G. 11.1 120.5
S.G. 8.1 117.9
S.Gi 6.9 125.,8
130.0
130.5
129.7
129.7
129.7
129.7
129.7
129.7
129.7
129.7
i33.5
91.1
94.9
92.9
90.9
94.2
SOIL AND MATRRIAL TESTINO XARORATORY
_ Date Test Re- Location Ht. of Field Field Maximum Relative
of No. test of Test Fill Moisture Dry Dry
Test of Pad No. Tested Contont Density Density ComT;;tion
-1973 Test (Feet) (%) (pcf) (PCf) - No.
5-15 135 - Parking Area
East of
Pad D-2
136 '
137
138
139
140
141
142
143
144
-16 .I45
146
147 124
5-17 148
149
150
151
152
5-18 153 117
5-21 154
155
C-l
B-2
B-5
Fill Slope
West of
Pad P-l
Parking Area
East of
Pad B-2
J-3
J-4
Fill Slope
West of
Pad P-3
P-l
P-3
Parking Area
East of
Pad E-2
H-2
Parking Area
East of
Pad P-l
Parking Area
East of'
Pad P-l
xx
xx
xx
F-4
Parking Area
East of
Pad P-l
N-3
156 Parking Area
East of
Pad Q-4
S.G. 8.7 115.5 123.1 93.8
F.G. 4.7 , 120.5 123.0 98.0
F.G. 6.4 117.0 123.0 95.0
F.G. 7.5 104.6 115.0 91.0
1.0 9.3 120.8 129.7 93.1
S.G. 8.7 118.0 129.7 91.1
F.G. 6.4 117.5 129.7 90.6
F.G. 6.4 119.5 129.7 92.1
3.0' 9.3 118.7 129.7 91.5
5.0 9.9 118.9 129.7 91.7
7.0 11.1 120.0 130.0 92.3
S.G. 8.1 130.6 133.5 97.8
F.G. 8.7 120.2 131.2 91.6
2.0 12.3 106.8 115.0 92.9
4.0 9.3 119.9
F.5;. 9.9 120.2
F.G. 9.9 119.8
F.G. 11.1 121.0
F.G. 8.1 117.0
6.0 8.7 120.5
30.0 903 119.7
S.G; 8.1 121.1
130.0
130.0
129.7
130.0
129.7
130.0
129.7
r133.5
92.2
92.5
92.4
93.1
90.2
92.7
92.3
90.7
SOLt AND MATIZRIAL TESTINO LABORATORY
-
Date Test Ro- Location Ht. of Field Field Maximum Rslativa
of No. test of Test Fill Moisture Dry Dry Test of Pad No. Tested Content
.-- 1973 Test (feet) (96)
Density Density
(PC0 (PCf>
Comyi;tion
5-21 157 -
158 -
5-22 159 -
160
161 - 162
L
163
164
I
5-23 165
Parking Area East of
Pad O-4
Parking Area
East of Pad N-4
o-4
o-3
N-4
N-3 .
P-l
P-3
Fill Slope
West of
Pad N-3
Ii
166 Fill Slope
West of
Pad O-3 .
/
-
,167
-
168
Parking Area
East of
Pad P-l
Fill Slope
West of
Pad P-l
- S.G. = Sub Grade
F.G. = Final Grade
S.G. 9.3 124.2
S.G. 7.0 120.7
F.G. 8.7 127.0
F.G. 9.3 118.2
F.G. 8.1 119.0
F.G. 7.5 117.0
F.G. 5.8 106.4
F.G. 11.1 120.8
-1.0 6.4 117.5
-1.0
S.G. 8.7 121.7
-1.0 6.4 119.0
117.1
130.0
130.0
130.0
130.0
129.7
129.7
115.0
129.7
130.0
130.0
130.0
130.0
95.6
92.8
97.7
90.9
91.8
90.2
92.5
93.1
90.4
90.1
93.6
91.5
SOIL AND MATZRXAL TESTINGI LABORATORY
FIELD DENSITY TEST RESULTS
STREET TESTS -
-Date Test Location Ht. of Field field Maximum Relative
of No. of Test Fill Moisture Dry Dry - Test Tested Content
(F.eet)
Density
(pcf)
Density
Comgtion
. 1973 (pcf)
5-3 -
-
- 5-5
-
-
5-8
-
-
-
-
-
-
-
-
-
-
1
2
3
4
5
6
7
8
9
IO
11
12
13
14
15
16
17
18
19
Fill Slope 2.0
West of Cul-De-Sac
of ttBtt Street
Fill Slope 4.0 West af Gul-De-Sac of "El" Street
Fill Slope 2.0
East of Louder Ln.
Fill Slope 4.0
East of Lowder Ln.
Fill Slope 6.0.
East of Lowder Ln.
Fill Slope 4.0
East of Lowder Ln.
fill Slope 8.0
East of Lowder Ln.
fill Slope 8.0 East of Lowder Ln.
Fill Slope 10.0
East of Lowder Ln.
Fill Slope 12.0 East of Lowder Ln.
Fill Slope 14.0
East of Lowder Ln.
Fill Slope 16.0 East of Lowder Ln.
fill Slope 12.0
East of Lowder Ln.
Fill Slope 18.0
East of Lowder Ln.
Fill Slope 20.0
East of Lowder Ln.
Fill Slope 22.0
East of Lowder Ln.
Fill Slope 24.0
East of Lewder Ln.
fill Slope 26.0
East of Louder Ln.
fill Slope 30.0
7.5 119.9 130.0 92.2
7.5 117.0 130.0 90.0
8.7 120.7 130.0 92.8
8.7 119.3 129.7 92.1
9.3 117.0 123.0 95.1
6.9 124.2 133.5 93.0
8.1 125.2 133.5 93.8
11.1 114.6 123.0 93.2
11.7 115.6 123.0 94.0
11.1 114.0 123.0 92.7
10.5 124.0 133.5 92.9
11.7 125.8 133.5 94.2
12.3 125.3 133.5 93.9
8.7 117.8 130.0 90.6
10.5
10.5
9.9
10.5
9.9
113.8 123.1 92.4
123.1 131.2 93.8
120.1 130.0
125.1 131.2
121.0 130.0
92.4
95.4
93.1
East of Lewder Ln. SOIL AND MATERIAL TESTING LABORATORY
OF NORTH OOUNTY, #NO. I?
Date Test Location
of No. of Test
Test
1973 -
Ht. of field field Maximum Relative
Fill Moisture Dry Dry Tested Content Density Density
Comgtion
(Feet) %) (pcf) (pcf) .- -9 20
21
_-
22
23
24
25
26
27
28
29
30
31
32
33
34
35
S-10 36
37
38
39
40
Fill Slope 2.0
East of Lowder Ln.
Fill Slope 2.0
East of Lowder Ln.
Fill Slope 4.0
East of Lowder Ln.
Fill Slope 6.0
Eaet of Lauder Ln.
Fill Slope 8.0
East of Lowder Ln.
Fill Slope 10.0
East of Lowder Ln.
fill Slope 12.0
East of Lowder Ln.
Fill Slope 6.0
East of Lowder Ln.
Fill Slope 14.0
East of Lowder Ln.
Fill Slope 10.0 East of Lowder Ln.
Fill Slope 16.0
East of Lowder Ln.
Fill Slope 16.0
East of Lewder Ln.
Fill Slope 18.0
East of Lowder Ln.
Fill Slope 14.0
East of Lowder Ln.
fill Slope 20.0 East of Lowder Lane
Fill Slope 20.0 East of Lowder Lane
Lowder Lane 18.0
Lowder Lane 24.0
Lowder Lane 24.0
Lowder Lane 34.0
Lowder Lane 28.0 -
5-12 41 fill Slope 6.0
West of Cul-De-Sac
of aB1t Street -
42 fill Slope 8.0
West of Cul-De-Sac
of “B" Street -
9.3 123.0 133.5
9.9 121.4 131.2
8.7 122.4 133.5
10.5 121.5 130.0
8.7 119.5 129.7
12.3 106.8' 115.0
9.3 121.6 130.0
SOIL AND lKATERIAL TESTING LABORATORY
OF NORTbI OOUNTY, INO. Ik
11.1 119.2 130.0 91.7
10.5 118.4 130.0 91.1
11.1 121.1 131.2 92.3
11.7 120,4 131.2 91.8
10.5 121.0 131.2 92.2
11.1 122.1 130.0 93.9
11.1 120.6 131.2 91.9
11.1 120.7 129.7 93.1
10.5 121.3 129.7 93.5
11.7 117.4 130.0 90.3
9.3 122.0 131.2 93.0
9.9 117.9 123.1 95.8
9.3 120.5 131.2 91.8
13.6 121.3 123.1 98.6
10.5 118.0 123.1
9.9 120.3 130.0
95.9
92.5
92.1
92.5
91.7
93.5
92.1
92.9
93.5
-
’ Date Test Location Ht. of Field Field Maximum Relative
of No. of Test Fill Moisture Dry Dry Test Tested Content Density Density ComT;;tion
-1973 (Feet) %I (pcf) (pcf) - 1
. 5-21 43 Cul-De-Sac S.G. 6.9 117.0 129.7 90.2
rt8tt Street
-, 5-23 44 Fill Slope 22.0 6.4 118.4 130.0 91.1
East of Louder Lane -
-
-
-