HomeMy WebLinkAboutCT 72-20; 3171 Venado Street Condominium Complex Unit 2; Soils Report Addendum to Third Interim; 1986-11-04CATLIN ENGINEERING, INC.
P.O.Box4225
La Mesa, California92044-0970
(619) - (619) 588.85OQ
-
-
-
-
Continental American Properties 1764 San Diego Avenue
San Diego, CA 92110
ATTN: Mr. Vic Baker
November 4, 1986
Subject: Project No. 2OC5C
Addendum to Third Interim Report of Compacted Filled Ground
Proposed Condominium Complex 3171 Venado Street Carlsbad, California
Gentlemen:
We refer to our First Interim Report of Compacted Filled Ground prepared for subject site dated March 12, 1986, Second Interim Report of Compacted Filled
Ground dated October 9, 1986 and Third Interim Report of Compacted Filled
Ground dated November 3, 1986, and to reports by Benton Engineering, Inc, Final Report of Compacted Filled Ground dated November 27, 1974 and Site Inspection and Recommendations for Construction dated July 22, 1981.
This addendum records our observations and the results of tests performed in connection with our inspection of the compaction of filled ground placed on
certain areas of the above subject property. This property is more
particularly referred to as Assessors Parcel Nos. 223-190-05, -06, -07, and
-08 in the City of Carlsbad, County of San Diego, State of California.
The grading reported herein was accomplished on November 3, 1986.
The elevations of fill at which the tests were taken and the final test
results are presented on page T-15 under "Table of Test Results". The
laboratory determinations of the maximum dry density and-the optimum moisture content of the fill soils are set forth on page L-l under "Laboratory Test
Results". The approximate location of the filled ground and the field density tests are presented on Drawing No 6 revised November 4, 1986, entitled "Approximate Location of Compacted Filled Ground".
The results of the tests and observations indicate that the soils placed on
subject site under our inspection have been compacted to at least 90 percent of maximum dry density. We note for clarity that the building pad for lot 278 is complete. The remainder of our third interim report of compacted filled
ground remains in force.
Pages T-15, L-l, and Drawing No. 6 are parts of this report.
Consulting Engineers and Geologists
- PAGE 2 CONTINENTAL AMERICAN/VENADO STREET 2OC5C NOVEMBER 4, 1986
- The opportunity to be of service is sincerely appreciated.
Respectfully submitted, CATLIN ENGINEERING, INC.
Civil Engineer
- Distr. (6) Addressee
-
-
-
-
-
-
-
--~
_-
-
.-
-
_-
-
-
-
-
-
PAGE T-15 CONTINENTAL AMERICAN/VENADO STREET 2oc5c NOVEMBER 3, 1986
REVISED: NOVEMBER 4, 1986
TABLE OF TEST RESULTS
Field Density Tests were performed in accordance with the applicable provisions of the current ASTM Standard D1556 and the results are presented below.
Test Location Test No. of Test Elevation
SEE DRAWING R5 245 LOT 282 FG/243.0
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
II FG/244.0
LOT 283 S.G.
II S.G.
II S.G.
LOT 278 227.0
LOT 279 -3.5
LOT 278 229.5
II 230.0
II 230.5
LOT 277 FGl235.0
LOT 277 231.0
II 235.0
II 235.0
II 238.0
II 238.0
LOT 278 FG/232.5
II FG/232.5
Field
Moisture % Dry Wt.
Dry Density lb/tuft
Soil
Type
12.7 122.9 J
8.3 120.7 J
11.7 121.7 B
7.9 127.1 B
7.0 122.0 B
11.9 123.3 J
14.3 118.2 G
15.5 112.0 F
15.0 110.0 L
17.4 109.9 L
18.9 104.2 A
18.6 106.9 L
18.1 113.7 A
16.2 112.3 A
15.1 114.7 G
17.9 118.4 G
11.0 131.7 J
18.0 118.1 G
Compac- Test
tion % Date Remarks
92.3 10-23-86
90.7 "
95.2 10-31-86
99.5 n
95.5 "
92.7 "
99.9 n
91.4 11-01-86
95.7 "
95.8 '
91.6 ’
93.0 I4
99.9 n
98.7 ”
96.9 ’
97.8 ”
98.9 11-03-86
99.7 ”
-
-
-
-
.-
-
-
-
-
-
-
PAGE L-l CONTINENTAL AMERICAN/VENADO STREET 2OC5C NOVEMBER 4, 1986
LABORATORY TEST RESULTS
The maximum dry density and optimum moisture contents of the soils as
determined by the ASTM D1557-70 method, that uses 25 blows of a 10 pound
rammer falling from a height of 18 inches on each of 5 layers in a 4 inch diameter l/30 cubic foot compaction cylinder, are presented as follows:
Soil
Type
A
B
C
D
E
F
G
waw/A
Soil
Description
Gray Tan silty Clay
Red Brown Very Fine to Coarse Clayey Sand
Green With Red Streaks Silty Clay
Medium Brown Silty Fine Sand
With Clay Binder
Tan Yellow silty Clay
Light Brown-Orange clayey Fine to
Coarse Sand
Olive Brown Fine to Medium
Clayey Sand
Gray Silty Fine to Coarse Sand
Gray Brown Silty Fine to Coarse Sand
Brown Clayey Fine to Coarse Sand
Brown Silty Fine to Coarse Sand
(Import)
Maximum Dry Dens
lb/cu.ft
113.8
127.8
106.3
122.9
120.4
122.6
118.4 14.0
137.4 6.9
138.6 7.2
133.1 8.9
125.5 8.7
ity
Optimum
Moisture
Content % Dry Wt.
16.4
9.5
15.4
12.0
13.0
12.7