HomeMy WebLinkAboutCT 73-24; Carlsbad Lake Community; Soils Report; 1981-01-21Wobdward-Clyde Consultants
.
UPDATE GEOTECHNICAL INVESTIGATION
CARLSBAD LAKE COMMUNITY
(CARLSBAD TRACT NO. 73-24)
CARLSBAD, CALIFORNIA
prepared for:
Plaza Builders, Inc.
16800 Devonshire Street
Granada Hilla, California 91344
-i
3467 Kurlz Street San Diego Callforrta 921 10
714-224-2911
Telex 697-841 .
January 21, 1981
Project No. 50316W-UD01
.
Woodward=Clyde Consultants
Plaza Builders, Inc.
Granada Hills, California 91344
16800 Devonshire Street
Attention: Mr. Ed Hamner
UPDATE GEOTECHNICAL INVESTIGATION
CARLSBAD LAKE COMMUNITY
(CAFLSBAD TRACT NO. 73-24)
CARLSBAD, CALIFORNIA
Gentlemen:
In accordance with your request and our proposal dated
December 2, 1980, we have prepared an update report of the
soil and geologic conditions on the subject site. This
conforms to Phase I of the studies presented in our pro-
posal.
SCOPE AND PURPOSE OF STUDY
Our study consisted of reviewing our files concerning
the site, making a field reconnaissance and reviewing up to
date applicable geologic literature. The purpose of this
work was to provide a basis for our report and to provide
criteria for development of the site including conclusions
and recommendations regarding:
0 The possible presence of geologic hazards on the
0 The stability of proposed cut and fill slopes,
0 Foundation design, including allowable soil
site,
bearing pressures in natural ground and compacted
fill, and,
0 Earthwork and grading specifications.
Plaza Suilders, Inc. January 21, 1981
Project No. 50316W-UD01
Page 2
Woodward-Clyde Consultants
.
PREVIOUS SOIL STUDIES
A preliminary soil investigation of the site was
prepared by Woodward-Gizienski and Associates. The results
of that study were issued in a report entitled "Soil Investi-
gation for the Proposed Carlsbad Lake Community, Carlsbad,
California," dated July 30, 1973. A copy of that report is
attached (Appendix A).
DESCRIPTION OF PROPOSED PROJECT
The subject site is east of Interstate 5 and south of
Poinsettia Lane in Carlsbad, California. For our study, we
were provided a copy of "Plot and Grading Plan, Carlsbad
Tract No. 73-24," prepared by Lawrence R. Williams Consulting
Civil Engineer dated August 5, 1974 with latest revision
dated June 14, 1976. Except for minor changes this plan is
essentially the same as that studied for the 1973 Woodward-
Gizienski & Associates investigation.
The plan indicates that the site will be graded to form
building pads for construction of 67 multi-story condominium
type structures. The plans also indicate that cut slopes
will have maximum heights on the order of 15 feet and slope
inclinations of 2 to 1 and that fill slopes will have maxi-
mum heights on the order of 25 feet and 15 feet with slope
inclinations of 2 to 1 and 1-1/2 to 1, respectively. The
1-1/2 to 1 inclined fill slope is proposed along the western
property line approximately 30 feet east of the top of an
existing 2 to 1 inclined cut slope extending down to Inter-
state 5. This existing cut slope has a maximum height on
the order of 30 to 40 feet.
The plans also indicate that two shallow, on the order
Of 4 feet deep decorative ponds will be constructed in the
central portion of the site.
-~
!
-I
Plaza Builders, Inc. January 21, 1981
Project No. 50316W-UD01
Page 3
Woodward-Clyde Consultants
.
CURRENT SITE CONDITIONS
The site is located on a relatively flat north-south
trending ridge. The ridge top slopes gently to the west.
The major portion of the site has been cultivated to depths
of 1 to 2 feet sometime in the past. These cultivated
topsoils consist of silty to clayey sands. Underlying the
topsoils are the Quaternary age Lindavista Formation and the
Eocene age Santiago Formation. A review of the grading
plans and our field reconnaissance indicates that all pro-
posed cuts will be in the Lindavista Formation. These
materials are dense to very dense silty to clayey sands.
As noted in the 1973 report a small area of uncompacted
fill was found in the west-central portion of the site.
This fill extended to a depth of 13 feet and consists of
silty to clayey sand. NO new fill was noted on the site.
Man-made structures on the site consist of a waterline
(shown on the plans) present along the eastern site boundary
and a sewerline (not shown on the plans) present along the
western site boundary. Although not observed during our
site reconnaissance, abandoned irrigation lines may be
present.
Vegetation consists of a dense growth of native weeds
and grasses.
GEOLOGIC HAZARDS
Faulting
For this study we have reviewed our files and published
literature including the "Geology of the Encinitas Quadrangle,"
prepared by Kenneth iiilson in 1972. The review did not
indicate the presence of any known faults on the site, nor
was any surface evidence of faulting noted on the site or
the ridge side slopes during our site visit.
-I
I
Plaza Builders, Inc. January 21, 1981 Project No. 50316W-UD01
Page 4
Woodward-Clyde Consultants.
.
The nearest known active fault along which seismic
events of Richter Magnitude 4.0 or greater have been re-
corded is the Elsinore Fault zone, mapped approximately 25
miles northeast of the site. The hypothesised northern
extension of the Rose Canyon Fault zone is located approxi-
mately 5 miles west of the site. No earthquakes greater
than Richter Magnitude 4 have been recorded for this fault.
Landslides
In addition to other work previously mentioned, our
evaluation of the potential for landslides included re-
viewing aerial photographs and general topography of the
site. No landslides or landforms that could be construed as
landslides were noted.
Ground Water
No water seeps or springs were noted during our recent
site visit. No ground water was encountered in the test
borings made for the 1973 investigation. We do not expect
that a ground water table is present within proposed grading
depths.
DISCUSSIONS, CONCLUSIONS, AND RECOMMENDATIONS
The discussions, conclusions, and recommendations
presented in this report are based on results of our field
studies, analyses and professional judgment.
The results of our field reconnaissance, made by a
senior staff geologist of our firm on January 7, 1981,
indicates that the site is in essentially the same condition
as it was for the 1973 field investigation, although no
actual surveying was done.
Plaza Builders, Inc. January 21, 1981
Project No. 50316X-UD01
Page 5
Woodward-Clyde Consultants
Potential Geologic Hazards
Faulting - Our investigation identified no faults
crossing the site.
Seismicity - All faults have a potential for earth-
quake activity. The fault zone closest to the site along
which earthquakes of Richter Magnitude 4 or greater have
been recorded is approximately 25 miles from the site,
whereas the closest significant faulting to the site is
approximately 5 miles from the site but this fault has not
exhibited earthquakes greater than Richter Magnitude 4.
Liquefaction Potential - We estimate that the depth to
the regional ground water table is in excess of 50 feet. In
our opinion, this depth, together with the dense nature of
the soils on the site generally precludes the possibility of
liquefaction.
Landslides - Our field investigation and review of maps
and vertical aerial photographs disclosed no evidence of
landslides on the site.
Ground Water
In our opinion, no shallow permanent ground water table
exists on the site and the conditions of the proposed
development indicate a low probability of ground water seepage
problems resulting from existing subsurface water.
We recommend that positive measures be taken to prop-
erly finish grade the building areas after structures and
other improvements are in place so that drainage water from
lots is directed off the lots to the street and away from
foundations, floor slabs, and slope tops. Even with these
provisions, experience has shown that a shallow ground water
or surface water condition can and may exist in areas where
no such ground water condition existed prior to site develop-
-I
-1
Plaza Builders, Inc.
January 21, 1981
Project No. 50316W-UD01
Page 6
Woodward-Clyde Consultants
ment. This is particularly true where a substantial in-
crease in surface water infiltration results from landscape
irrigation.
Slope Stability
For the proposed slopes we have performed stability
analyses using the Janbu method of analyses and the follow-
ing soil strength parameters:
Area - ra' C' (psf) Y (pcf)
Cut Slopes 30' 300 125
Fill Slopes 25 O 250 120
These parameters are based on laboratory tests per-
formed for the 1973 field investigation report and our
experience with similar soils in nearby areas.
Our analyses indicates the proposed slopes will have
calculated factors of safety in excess of 1.5 under static
conditions for both deep-seated and shallow sloughing.
Stability analyses require the use of soil parameters
selected from a range of possible values, thus, there is a
finite possibility that slopes having calculated factors of
safety as indicated above could become unstable. In our
opinion, the probability of the slopes becoming unstable is
low and it is our professional judgment that the slopes can
be constructed as planned.
IJe recommend that all slopes be planted, drained and
properly maintained to help control erosion. Our experience
indicates that slopes constructed at steeper than 2 to 1 are
particularly susceptible to shallow slope sloughing during
periods of heavy rainfall, heavy irrigation or upslope
surface runoff. Periodic maintenance, including the re-
building of the outer 18 to 36 inches of the slope, may be
Woodward-Clyde Consultants January 21, 1981
Plaza Builders, Inc.
Projec-t No. 50316W-UD01
Page 7 .
required. Sloughing of fill slopes can be reduced by
overbuilding the slope by at least 3 feet and cutting back
to the desired slope inclination.
Sloughing can also be reduced by backrolling slopes at
frequent intervals. We recommend that all fill slopes be
backrolled at least every 4 feet of fill height and that 2
to 1 inclined fill slopes be trackwalked upon completion.
Earthwork
We recommend that the site be graded in accordance with
the attached Specifications for Controlled Fill (Appendix
B) . Me also recommend that the grading be observed by and
compacted fills be tested by Woodward-Clyde Consultants.
We recommend that a pre-construction conference be held
at the site with the developer, civil engineer, contractor
and geotechnical engineer in attendance. Special soil
handling and the grading plans can be discussed at that
time .
We recommend, in areas to receive new fill or structures,
that the existing fill and underlying porous topsoil in the
west-central part of the site be excavated, watered as
required and compacted. The 1973 report indicates the maxi-
mum combined depth of existing fill and porous topsoil is
on the order of 13 feet, however, we recommend that the
actual depth and extent be evaluated in the field at the
time of grading.
We recommend that all other loose and/or cultivated
topsoils not removed by planned grading operations be ex-
cavated, watered as required, and compacted prior to placing
additional fill or structures.
Although no expansive soil were noted during either the
1973 or current investigations, our experience in nearby
Woodward-Clyde Consultants
Plaza Builders, Inc. January 21, 1981
Project No. 50316W-LID01
Page 8
areas indicates that residual clayey soils may be en-
countered locally beneath the topsoils. If expansive clay
soils are found during grading, we recommend that they be
excavated where encountered, a minimum depth of 2 feet below
rough grade in building areas and 1 foot in pavement areas.
The building area is defined as the area of the building
plus 5 feet beyond the building limits. The clay soils can
be replaced with properly compacted nonexpansive granular
soils available on the site.
We recommend that the upper 2 feet of fill in building
areas and 1 foot in pavement areas be composed of properly
compacted nonexpansive granular soil available on the site.
We recommend that all cut areas be examined by our
firm during grading to evaluate actual geologic conditions.
Foundations
We recommend that foundations for the proposed build-
ings founded in either undisturbed or properly compacted
nonexpansive materials be designed for an allowable soil
bearing presure not exceeding 2,000 psf (dead plus live
loads) at 12 inches below compacted fill or undisturbed cut
lot grade. In our opinion, this soil bearing pressure can
be increased by no more than one-third for loads that in-
clude wind or seismic forces. We recommend that all con-
tinuous footings have minimum widths of 12 inches.
We recommend that structures that cannot tolerate
differential settlements (foundations, floor slabs, decks,
etc.) not be located within 8 feet of the face of a slope.
For structures located in this zone we recommend the foot-
ings be extended in depth until the outer bottom edge of the
footing is at least 8 feet from the face of the slope.
I -I
Plaza Builders, Inc. January 21, 1981 Pro jecc No. 50316W-UD01
Page 9
Woodward-Clyde Consultants
.
Recommendations for pond construction are not within the
scope of this report. Recommendationa in this regard can be
presented in an addendum report upon request.
RISK AND OTHER CONSIDERATIONS
We have only observed a small portion of the pertinent
soil, and ground water conditions. The recommendations made
herein are based on the assumption that soil conditions do
not deviate appreciably from those found during our field
investigation. If the plans for site development are
changed, or if variations or undesirable geotechnical condi-
tions are encountered during construction, the geotechnical
consultant should be consulted for further recommendations.
We recommend that the geotechnical consultant review
the foundation and grading plans to verify that the intent
of the recommendations presented herein has been properly
interpreted and incorporated into the contract documents.
We further recommend that the geotechnical consultant
observe the site grading, subgrade preparation under con-
crete slabs and paved areas, and foundation excavations.
It should also be understood that California, including
San Diego, is an area of high seismic risk. It is generally
considered economically unfeasible to build totally earth-
quake-resistant structures; therefore, it is possible that
a large or nearby earthquake could cause damage at the site.
Professional judgments presented herein are based
partly on our evaluations of the technical information
gathered, partly on our understanding of the proposed con-
struction, and partly on our general experience in the
geotechnical field. Our engineering work and judgments
rendered meet current professional standards. \Ye do not
guarantee the performance of the project in any respect.
Plaza Builders, Inc.
January 21, 1981 Project. No. 50316W-UD01
Page 10
Woodward-Clyde Consultants
.
This firm does not practice or consult in the field of
safety engineering. We do not direct the contractor's
operations, and we cannot be responsible for the safety of
other than our own personnel on the site; therefore, the
safety of others is the responsibility of the contractor.
The contractor should notify the owner if he considers any
of the recommended actions presented herein to be unsafe.
If you have any questions, or if we can be of further
service, please give us a call.
Very truly yours,
WOOD:qARD-CLYDE CONSULTANTS
Richard P. While
R.E. 21992
RPW/DS/MRR/rs
Attachments
(4) Plaza Builders, Inc.
(4) Lawrence R. Williams Consulting
Civil Engineer
Daryi Streiif
C.E.G. 1033