HomeMy WebLinkAboutCT 74-15; Las Costa Estates North; Preliminary Soils Report; 1986-11-24City of Carlsbad .' I Engineering Dept.
Carlsbad, CA. 92008 2075 Las Palmas Drive
c/o Zoltan Kasa
Carlsbad,.CA. 92008 2926 Via Pepita
1535 S. Elcondido Blvd. Elcondido. CA 92025
(619) 7414533
LAND DEVELOPMENT
Surveying ~ Perc Tats - Lot Splits
Grading Plans & Comp.ction TCSII
November 24, 1986 ,
Re: 7336 El Fuerte Street NQ~ 2 6 19" Lot 60 of, Las Costa Estates North, Map 8302
Subject: PRELIMINARY SOILS INVESTIGATION FOR OF. CWS BRD
PROPOSED SINGLE FAMILY RESIDENCE ,C\O DaEL~~. PRO''
si~\J. b>\v
TO WHOM IT MAY CONCRRN:
Per the request of Zoltan Kasa, our firm has conducted a Prelim
inary Soils Investigation of the Soils found at the above refer
enced site. This report represents the findings and recomrnenda
tions for the proposed development based upon the results of
this investigation.
This investigation consisted of a site geologic reconnaissance,
and the drilling of several 12 inch diameter auger borings.
Laboratory testing was performed on representative soils samples
obtained from these borings in order to evaluate pertinent
physical properties. The conclusions and recommendations that
follow are based upon review of the proposed development, inspe
ction of the site, an analysis of the data obtained and our
experience with similar soil conditions.
ENGINEERING DEPT. LIBRAW City of Carlsbad 2075 Las Palmas Drive
Carlsbad CA 92009-4859
CIVIL ENGINEERING LAND SURVEYING
PROJECT SCOPE
Explore the subsurface conditions to the depths influenced
by the proposed construction.
Evaluate, by laboratory tests, the pertinent engineering pro-
perties of the various strata which will influence the develop-
ment, including their bearing capacities, expansive character-
istics and settlement potential.
Define the general geology at the site including possible geolo
gic hazards which could have an effect on the site develop-
ment.
Determine potential construction difficulties and provide re-
commendations concerning these problems.
Recommend an appropriate foundation system for the type of
structures anticipated and . develop soil engineering design
criteria for the Tecommended design.
THE SITE
The' site consists of residential lots of approximately 0.5 acre
located on the southeast side of El Fuerte Street in the City.
of Carlsbad. This lot was created as part of the La Costa Estates
North Tract 154. Street grading and improvements along with partial
lot grading was completed in November 1976 and certified by Benton
Engineering of San Diego.
The parcel slopes from its northern most corner at El Fuerte Street
to the southerly corner with a difference in elevation of approx-
imately 22'. The site is covered with low grass and brush common
to the area.
Numerous large single family residences have been constructed
on other similiar lots surrounding the site. The immediate adjacent
lots to the North and East are still vacant.
A residential Grading Plan has been prepared by this Engineer
for development of this lot. Cuts and fills proposed will approach
8' in height.
FIELD INVESTIGATION
In November 1986, we made a field review of the site along with
the borings of numerous 12" auger borings within the proposed
grading area.
The soil profile was identical over the site as determined from
those borings. The upper 5' of soil found over the site consists
of clayey-silts with fractured rock fragments. These soils are
considered to be expansive in character. This soil layer is under-
lain by Santiago Peaks Volcanic formation. This formation consists
of a very hard brittle rock formation that fractures into 2" to
6" pieces when ripped with conventional heavy grading equipment.
This fractured rock when mixed with surface soils will form a
suitable embankment for the proposed development.
Also noted during our investigation was the presence of loose
layers of foreign debris that had been scattered over the lot.
This material will require removal during clearing operations
prior to grading.
No ground water was encountered during our investigation and ground
water will not be a problem during or after construction.
LABORATORY TESTS
Laboratory tests were performed in accordance with generally
accepted test methods of the American Society for Testing and
Materials (ASTM) and other suggested procedures. Selected
relatively undisturbed drive samples were tested for their
inplace dry density, moisture content and expansive potential.
The maximum dry density and optimum moisture content of the
near surface soils were determined in accordance with ASTM
Test D155770, Method A. In addition, a directshear test and
an expansion test were performed on samples remolded to 90%
of maximum dry density at optimum moisture content.
Field moisture content and dry density were determined for
representative undisturbed samples. This information was an
aid to classification and permitted recognition of variations
in material consistency with depth. The dry unit weight is
determined in pounds per cubic foot, and the field moisture
content is determined as a percentage of the soils dry weight.
Field classifications were verified in the laboratory by visual
examination. The final soils classifications are in accordance
with the Unified Soil CLassification System.
Direct shear tests were performed to evaluate bearing potential
along with maximum density testing and expansive analysis were
conducted. Maximum dry weight was determined to be 124 #/c.f.
@ 12.0% optimum moisture content. Testing was done for internal
shear based upon utilizing a 90% relative compaction. The
apparent angle of shear for the soils encountered = 18".
An expansion analysis of these soils was performed in accordance
with the UBC 292 test procedures. The result OF this test
indicated an index value of 72, which is considered to be
moderately expansive.
LABORATORY TESTS
Laboratory tests were performed in accordance with generally
accepted test methods of the American Society for Testing and
Materials (ASTM) and other suggested procedures. Selected
relatively undisturbed drive samples were tested for their
inplace dry density, moisture content and expansive potential.
The maximum dry density and optimum moisture content of the
near surface soils were determined in accordance with ASTM
Test D155770, Method A. In addition, a directshear test and
an expansion test were performed on samples remolded to 90%
of maximum dry density at optimum moisture content.
Field moisture content and dry density were determined for
representative undisturbed samples. This information was an
aid to classification and permitted recognition of 'variations
in material consistency with depth. The dry unit weight is
determined in pounds per cubic foot, and the field moisture
content is determined as a percentage of the soils dry weight.
Field classifications were verified in the laboratory by visual
examination. The final soils classifications are in accordance
with the Unified Soil CLassification System.
Direct shear tests were performed to evaluate bearing potential
along with maximum density testing and expansive analysis were
conducted. Maximum dry weight was determined to be 124 #/c.f.
@ 12.0% optimum moisture content. Testing was done for internal
shear based upon utilizing a 90% relative compaction. The
apparent angle of shear for the soils encountered = 18".
An expansion analysis of these soils was performed in accordance
with the UBC 292 test procedures. The result OF this test
indicated an index value of 72, which is considered to be
moderately expansive.
TECTONIC SETTING
La Costa, (Carlsbad) along with most of the southwestern portion
of California, San Diego County, and parts of Mexico are located
on a relatively stable tectonic plate. This plate is bounded
on the east by the San Andreas Fault, system and on the west
by the San Clemente Fault System. These faults contain many
other parallel faults which are essentially high angle strikeslip
faults with a NW/SE trend. Although the bounding fault systems
are active, the interior of the tectonic plate is not generally
disturbed by the fault movement.
Geological references indicate that not much damage will occur
from earthquakes of magnitude of less than 6 for sites over
eight miles from the fault. Since maximum probable earthquake
for the general San Diego area is in the order of 6 and since
the site is further than 8 miles from the major active faults
we can infer that the shaking problem will not be to great.
Current seismic design criteria as imposed by the U.B.C. should
be satisfactory to compensate for seismic action. There are
no existing landslides, faults or other natural disturbances
noted on the site or in the immediate area as determined from
air photos, and field inspections. This does not preclude the
possibility of sliding by poor grading or other man made practic
es. This site can be considered relatively free of geologic
hazards.
CONCLUSIONS & RECOMENDATIONS
The site may he utilized for the proposed development provided
the recommendations of this report are carefully followed.
The undisturbed native soils, properly compacted native soils
or combinations thereof, should adequately support the proposed
structures without detrimental settlement.
The site shall be cleared of all vegatation prior to any grading
or placement of embankment. Any uncompacted native soils shall
be compacted to a minimum of 90% relative compaction. The
Soil Engineer shall determine when the native soils are ready
for placement of embankment.
Adverse soil conditions also exist in the form of minor quanti-
ties of uncompacted fill and loose topsoils. These materials
will require complete removal and recompaction.
Retaining walls, which are not fixed at the top and have a
level backfill should be designed for an active soil pressure
equivalent to a fluid pressure of 60 pcf. Where the backfill
will be sloping 2:1, an active soil pressure of 65 pcf is reco-
mmended. These v,alues assume a drained backfill condition.
Wall drainage details should be provided by the project archi-
tect. All cut slopes shall be 2:l or flatter and all fill
slopes shall not exceed 2:l slope ratio. When retaining walls
are restrained at the top an active soil pressure of 85 pcf
shal.1 he used for design of the wall. A passive soil pressure
value of 160 psf shall be used.
A coefficient of friction of 0.45 may be assumed for resistance
to sliding between concrete and soil.
The anticipated total and/or differential settlements for the
proposed structures may be considered to he within tolerable
limits provided the recommendations presented in this report
are followed.
The recommendations presented in this report are contingent
on review of final plans and specifications. It is recommended
that H.L. Land Development, Engineering and Surveying, be re-
tained to provide continuous soil engineering services during
the earthwork operations. This is to observe compliance with
the design concepts, specifications, and recommendations and
to allow design changes in the event subsurface conditions
differ from those anticipated prior to start of construction.
All existing topsoils shall be removed to a depth of 2.0 feet
below existing ground level. This material shall then be recom-
pacted into a dense embankment of at least 90% relative compac-
tion, with a moisture content within 2.0% of optimum.
Minimum foundation shall be 15 inches wide and founded 18 inches
below grade and shall have two #4 bars of reinforcing steel.
One bar shall be placed 4 inches below the top of foundation
and the other bar shall be placed 4 inches from the bottom
of foundation. These recommendations are based upon soil charac-
teristics only and do not reflect any possible design considera-
tions imposed by building design which might increase these
recommendations. The proposed foundations may be designed util-
izing an allowable bearing pressure of 1300 lb/sf. This value
may be increased by 1/3 for the design of loads that include
wind and seismic analysis. Slab on grade shall be reinforced
with 6x6xlOga wire mesh over visqueen vapor barrier and 4 inches
Of clean sand. These recornfiendations are made based upon the
assumption that the expansive soils found on the site will
be used for foundation embankment.
It should be noted that additional or final foundation recommen
dations will be made and contained in the Final As Graded Report
when a more complete evaluation of actual soil that the foundat
ions will be founded in can be made.
The above minimum foundations requirements are bssed upon a
single story structure and the foundation depth would need
to be increased to 24 inches for a two story structure.
An alternate solution to elj.minate .the need for expansive design
foundations kould be to utilize a good quality non-expansive
imported material over the top 3.0 feet of the building pad.
All embankment shal.1 be co~~~pac~etl to a nIiniluum of 90% relative
compacti.on and all existing ground wi.thin 5.0 feet laterally
and to a depth of 1.0 foot below the bottom of foundations
shall be compacted to at ].east 908 relative compaction. The cut
portion of the pad site shall be sub-excavated to a depth
of 2.0 feet below finish pad grade and the material watered
to optimum and recompacted to provide a uniform finished pad.
The recommendations and opinions expressed in this report re-
flect our best estimate .OF the project requirements based on
an evaluation of the subsurface soil conditions encountered
at the subsurface exploration locations and the assumption
that the soil conditi~ons do not deviate appreciably from those
encountered . It should be recognized that the performance
of the foundations may be influenced hy undisclosed or unforseen
variations in the sojl conditions .tl~at may occur in the interme
diate and unexplored areas. Any un~~sual conditions no't covered
in this report that may be encountered during site development
should be brought 'to the attentio~~ of the Soils Engineer SO
that he may make modifications jf necessary.
,.
It is the responsib.ility of the Ilcveloper or their representa-
tive to ensure that the information and recommendations con-
tained herein are brought to the attention of the Engineer
and Architect for the project and incorporated into the project
plans and specifications. It is further their responsibility
to take the necessary measllres to insure that the contractor
and his subcontractors carry out sucl~ recommendations during
construction.
.
All grading shall be monitored by a qualified Soils Engineer
to insure compliance with these recommendations and all applicable
City of Carlsbad ordinances. Recommended grading specifications
are made part of the report and attached as Exhibit "A".
Respectfully submitted,
RCE 33220
.
1535 S. Escondido Hlvd. Escondido. CA 92025
(619) 741-0533
LAND DEVELOPMENT
Surveying. Pcrc Tests . Lo1 Splits
Grading Plans dr Compaction Tesls
RECOMMENDED GRADING SPECIFICATIONS
Prepared for: Zoltan Kasa
2926 Via Pepita
Carlsbad, CA. 92008
for the Of: A single family residende
7336 El Fuerte Street
Carlsbad, CA. 92008
Herald R. Lantis hereinafter described as the Soil Engineer, should
be consulted prior to any site work connected with site development to ensure compliance with these specifications. These specifications
they are attached and part thereto.
shall only be used in conjunction with the soil report of which
1.1 This item shall consist of all clearing and grubbing, prepar-
ation of land to be filled, filling of the land, spreading, compact-
ing, and control of the fill and all subsidiary work necessary
to complete the grading of the filled areas to conform with the
lines, grades and slopes as shown on the accepted plans.
tions. In the event that any unusual conditions not covered by
the special provisions are.encountered during the grading operations,
the Soil Engineer shall be contacted for further information.
2.0 Tests
work shall be the 'ASTM Test Procedure D1557-70. All densities shall
The standard test used to define maximum density of all compaction
be expressed as a relative compaction in terms of the maximum density
obtained in the laboratory by the foregoing procedure.
3.0 Any trees not utilized in landscaping, structures, weeds and other Clearing, Grubbing and Preparing Areas to be Filled.
rubbish shall be removed, piled or otherwise disposed of so as
to leave the areas that have been disturbed with a neat and finished
appearance, free from unsightly debris.
1.2 The Soil Engineer shall test and observe all grading opera-
.
3.2 Any septic tanks, if encountered, and debris must be
removed from the site prior to any building, grading
or fill operations. Septic tanks, including all con-
nectimg drain fields and other lines, must be totally
removed and the resulting depressions properly reconstruct-
ed and filled to the complete satisfaction of the super-
vising soil engineer.
3.3 All water wells on the site shall be capped according
to the requirements of the San Diego County Health Depart-
ment. The strength of the cap shall 'be at least equal
to the adjacent soil. The final elevation of the top
of the adjacent grade prior to any grading of fill oper-
ations.
3.4 All buried tanks, if encountered, must be totally removed
and the resulting depressions properly reconstructed
and filled to the complete satisfaction of the supervising
soil engineer.
3.5 All vegetable matter and soil designated as unsuitable
by the soil engineer shall be removed under the direction
of the direction of the soil engineer. The then exposed
surface shall then be plowed or sacrified to a depth
of at least ,eight inches and until the surface is free
from ruts, hummocks, or other uneven features which would
tend to prevent uniform compaction by the equipment to
be used.
3.6 The original ground upon which the fill is to be placed
shall be plowed or sacrified deeply, and where the slope
ratio of the original ground is steeper than 6.0 horizon-
tal to 1.0 vertical, the band shall be stepped or benched.
At the toes of the major fills and on the sideslope fills,
the base key shall be, as described elsewhere in this
report, at least 10 feet in width, cut at least three
feet into the undisturbed or native soil, and sloped
back into the hillside at a gradient of not less than
.
. ..
two percent. Subsequent keys should be cut into the
hillside as the fill is brought up the slope. The con-
struction of subsequent keying operations shall be deter-
mined- by the soil engineer during grading operations.
Ground slopes which are flatter than 6 to 1 shall be bench-
ed when considered necessary by the soil engineer.
3.7 After the foundation for the fill has been cleared, plowed,
or scarified it shall be disced or bladed until it is
uniform and. .free from large clods; brought to .the proper
moisture content by adding water or aerating; and recom-
pacted to a relative compaction of not less than 90 percent.
4. Materials
4.2
5.
5.1
5.2
5.3
5.4
5.5
Native soil, free of organic material and undesirable de-
leterious material, may be used as fill. Native soil which
building pads without the approval of the soil engineer.
is expansive, shall not be placed on the top two feet of
The materials for fill shall be approved by the soil engin-
eer before commencement of grading operations. Any import-
ed material must be approved for use before being brought to the site. The materials used shall be free from veget-
able matter and other deleterious material, and be nonex-
pansive. Expansive soil is defined as soil which expands
more than three percent when saturated at 90 percent relat-
charge of 150 psf.
ive compaction and optimum moisture content under a sur-
Placing, Spreading, and Compaction Fill Material
The selected fill material shall be placed in layers which,
Each layer shall be spread evenly and shall be thoroughly when compacted. shall allow adequate bonding and compaction.
material in each layer.
blade mixed during the spreading to ensure uniformity of
When the moisture content of the fill material is below that specified by the soil engineer, water shall be added
until the moisture content is as specified to assure thor-
ough bonding during the compaction process. When the moist-
by the soil engineer, the fill material shall be aerated
ure content of the fill material is above that specified
by blading or other satisfactory methods until the moist- ure content is as specified.
After each layer has been placed, mixed and spread even-
ly, it shall be thoroughly compacted to a relative compac- tion of not less than 90 percent.
When fill material includes rock, no rock will be allowed to nest, and all voids must be carefully filled with small
stones or earth and properly compacted. No rocks larger
than six inches in diameter will be permitted in the fill.
Compaction shall be by sheepsfoot rollers, multiple wheel
pneumatic-tired rollers, or other types of acceptable com-
pacting rollers. Rollers shall be of such design that they
will be able to compact the fill to the specified moisture content range. Rolling of each layer shall be continuous
over it's entire area and until the required density has
been obtained.
5.6
5.1
5.8
5.9
6.
6.1
6.2
6.3
6.4
Field density tests shall be made by the soil engineer
where sheepsfoot rollers are used, the soil may be dis-
be taken in compacted material below the disturbed sur-
turbed to a depth of several inches. Density tests shall
face. any-layer of fill or portion thereof is below the required
When these tests indicate that the density of
90 percent relative compaction, the particular layer or portion shall be reworked until the required density
has been obtained.
as specified above, until the fill has been brought to The fill operation shall be continued in compacted layers
the finished slopes and graded as shown on the accepted
plans.
Fill slopes shall be compacted by means of sheepsfoot
rollers or other suitable equipment. Compaction oper-
ations shall be continued until the slopes are stable.
All earthmoving and working operations shall be controlled
to prevent water from running into excavated areas. All
water shall be promptly removed and the site kept dry.
Disposal of Oversize Rock
Oversize rock shall be either exported from the site,
used for landscaping purposes, oc placed in designated
non-structural fill areas.
Prior to grading, the soil engineer shall be consulted
to approve any proposed nonstructural fill area, In
General, nonstructural fill areas will be acceptable
structures: e.g. rear yard fills at least 15 feet from if located outside of the"zone of influence" of proposed
posed utility lines)..
structures and beneath street areas (deeper than pro-
Oversize ' rock shall not exceed four feet in greatest
dimension, shall be placed in lifts not exceeding four
feet in thickness, and shall be placed in a manner that
will not produce "nesting" of the rock. The voids between
the rocks shall be completely filled with fine granular material.
NO oversize rock shall be placed within four feet of finish lot grade nor within the anticipated depth of utility lines, whichever is deeper. -
7. Engineering Observation
during the fill and compaction operations so that he
Field observations by the soil engineer shall be made
can express his opinion regarding the conformance of
the ^grading with the accepted specifications.
0. Seasonal Limits
No.fil1 material shall be placed, spread, or rolled while
unfavorable weather conditions. When the work is inter-' it is at an unsuitable high moisture 'content, nor during
rupted by heavy rain, fill operations shall not be resumed' until field tests by the soil engineer indicate that
the moisture content and density of fill are as previous-
ly specified .