HomeMy WebLinkAboutCT 76-06; ROYAL HOMES; SOILS REPORT; 1980-01-14DUCO·
e
Engineering, Inc. FOUNDATION 8: GEOLOGIC INVESTIGATIONS
FILL CONTROL -SOIL TESTING
1170 CENTRE DRIVE, SUITE F . WALNUT, CALIFORNIA 91789
(213) 964-3440 . 964-3449
REP 0 R T o F SOl L S I N V EST I GAT ION
T R ACT NUMBER 76-6
W EST SID E o F CHI N QUA PIN
A T S Y M E D R I V E
CARLSBAD, CAL I FOR N I A
AVENUE
FOR: Carlsbad Development Corp.
P.O. Box B .
Carlsbad, Ca. 92008
Job No.: 9-2.77
January 14, 1980
Page One ~
January 14, 1980' Job No.: 9-277
Introduction
This report presents the results of a soils investigation for a proposed 15 lot
residential subdivision, Tract No. 76-6 to be developed on the west side of
Chinquapin Ave. at Syrne Dr., in the City of Carlsbad, County of San Diego,
,California. Figure No. 1 presents a plot plan of the site showing the surface
features and soils data pertinent to this report.
The geologic conditions pertaining to the development of this site as proposed
are'contained in the Geologic Study dated 1-2-80, prepared by Bob Di~key, submitted
as a part of this report.
The object of this investigation was to gather information and data regarding the
surface and subsurface soils conditions upon which to base our recommendations for
site preparation, grading and construction of the proposed residential structures.
The results of our field and laboratory investigations which form the basis for
our recommendations are included 'as a part of this report.
Site Conditions
The subject site occupies a rectangular shaped parcel of property bounded oy
Chinquapin Ave. on the west and by houses and rural property on the remaining
three sides.
At the time of our field investigation the site contained a residential structure,
on proposed Lot No.5, with associated trees, shrubs, lawns and a shed along the
north property line. The remaining portion of the site is presently a producing
tomato and squash field.
The natural soils encountered consisted of firm to dense silty fine to medium
sands.
Current drainage of the site 1S qy sheetflow from the east to the west.
No ground water or caving of the test hole side walls were encountered in any of
the test holes to the depths excavated.
Field Investigation
The subsurface soils conditions were explored by excavating five (5) engineering
test holes to depths of 6 to 10 feet using a backhoe with an 18 inch wide bucket.
The app.roximate locations of the test holes are shown along with the surface
features and pertinent soils data on Figure No.1.
Both relatively undisturbed and disturbed bulk samples of the typical soils
encountered in the test holes were recovered to be subjected to laboratory
testing and analysis.
A continuous log of each test hole was kept in the field at the time of excavation.
These test hole logs, reflecting the condition and classification of each soil
strata encountered, based on the Unified System of Soil Classification, are attached
to this report as Figures 2 through 6.
Page Two
January 14, 1980 Job No.: 9-277
Laboratory Investigation
In-situ moisture and density tests were performed on the undistur'bed samples an~
the results of' these tests are shown on tl)e appropriate test hole' log at the
depth sampled~ Also shown are ,the results of tests made to determine the relative
compaction of the samples compared to the maximum density determined ~ith ASTM
test method D1557-70.
The expansion potential of the typical onsite soils were determined in accordance
with the U.B.C. test standard 29-2. The result of the laboratory tests performed
on the bulk samples of the typical soils are summarized as follows:
Soil Type
A Silty fine to
B -Silty fine to
C -Clayey sand
Hole No.
I
2
4
med.
med.
Max.
sand 127.0
sand 127.5
131.4
Depth, Ft.
8.0
2.0
2.5
Conclusions and Recommendations
Den.
P.C.F.
"
"
Opt. Moist. Expan~ Index
9:7 % 3
8.5 % 4
8.2 O.
Shear Angle Cohesion, P.S.F.
320 75
340 150
380 50
Development of the site, as proposed, is considered feasible from a soils engineer-
ing standpoint based on the implementation and incorporation of the recommendations
which follow ipto the site preparation, grading and construction of the proposed
residential structures.
Site Preparation and Grading
Prior to the start of grading; the existing trees not to remain shall be removed
and hauled offsite. The organic debris resulting from the tree removal and all
surface vegetation shall be stripped and hauled offsite to the satisfaction of the
soils engineer. Any remaining roots encountered during the grading operation
shall be picked and removed from the site.
The existing structures not to remain shall be demolished and hauled offsite. A
search shall be made to locate any underground private sewage disposal systems.
Any such systems encountered shall have the septic tanks removed and the cesspool
pumped as necessary and filled to within 5 feet of finished grade with clean sand
and, gravel jetted in place with water. The top 5 feet of the cesspool shall be
removed and ,the excavation brought to grade with compacted f~ll along with any
other excavation resulting from demolition or removal of a subsurface structure.
Prior to the placing of any fill soils, the surface of the natural ground to
receive fill shall be rerp.oved or windrowed t() a depth of 12 inches, watered as
necessary to obtain opti~um moisture content and precompacted to the minimum
requirements. A,similar grading procedure shall be implemented upon the finished
grade surface where proposed cuts to, create building, pads are less than 12 inches
in depth.
Page Three
January 14, 1980 Job No. 9-277
Site Preparation and Grading (con't.)
F'ill soils shall be spread in 6 inch loose lifts, watered as necessary and
compacted to in excess of 90% of the maximum density as determined by ASTM test
method D1557-70.
The anticipated subsidence in the surface soils due to processing of the natu~al
ground to receive fill, tree removal and processing of the surface of the shallow.
cut pads· is expected to be on the order of 2.0 inches. The anticipated shrinkage
in soil volume from cut to fill is expected to be on the order of 10 to 15%.
Expansive Soils
The results of the laboratory test performed on the typical soils types encountered
on the site indicate the soils are nonexpansive to very lowly expansive in nature.
Based on the results of these tests it is our opinion that no remedial construction
measures will be necessary providing that the proposed imported soils are also
of a nonexpansive nature. All import soils should be approved prior to reaching
the site.
Foundations
Based on provisions of the foregoing recommendations, the proposed residential
structures may be supported on conventional continuous and square footings designed
to obtain the required soil bearing at a minimum depth of 12 inches below the
lowest adjacent finished ground surface.
The recommended soil bearing value for footings imbedded as recommended into
compacted fill or firm natural ground shall be 1500 P.S.F.
The foregoing values are for dead and live loads and may be increased 1/3 for
temporary horizontal forces.
Cut and Fill Slopes
o The recommended maximum graded angle for cu~ and fill slopes ,shall, he 1~:1 (@34 ).,
Slopes constructed' at this angle are deemed grossly stable to the designed heights.
The recommendations contained in this report are based on the results of our field
and laboratory investigations combined with the principles of modern soil mechanics
and sound engineering judgement.
Should any unusual conditions arise during the design or construction of this project,
this firm shall be notified in order that proper modifications to the recommendations
contained herein may be made as d~emed necessary .
. Should you have any questions with regard to this report or the recommendations
,contained herein, please contact this office.
Respectfully submitted,
DUCO ENGINEERING, INC. Approved by:
.~ak
Ronald Cobine 10863
RC:mw
. e e
-.@ ~J I , i
0 CD
~s-
-~ tt: NO GRAJ)/NG
~2 I:::\ ;7 lli
S-
'" A
U) I
I
~ a
~
I
@ (j)
, . ~3
.. ~4
CHINQUAPIN AVE. ,
DUCO ENGINEERING ~ (9 LOCATION OF SCALE I": 60 '
:
,.
J TEST HOLE
JOB NO. 9-277 ,
1170 CENTRE DR., SUITE F, WALN UT, CALIF. FIGURE No.1
DATE DRILLED 12-28-79
Depth
In
Feet
o
-
·
-
5 -
-
-
-I-
I
.o-
lD
-
-
-
-
15 -
-
-
·
·
20 -
-
-
-
-
25
A 108.0 8.8
DUCO .Engineering, Inc.
LOG OF BORING NO. 1 PROJECT NO. 9 .... 277
FlELD CLASSIFICATION
Silty fine to medium sand ~ brown -firm -damp
Material becomes reddish brown in color and moist
85.0
FIGURE NO.
DATE DRILLED 12-28-79
Depth
In
Feet
o
-
~
1 --
-
5 -
-
-
.--
-'
10 -
-
-
-
15 -
-
-
-
20 -
-
-
-
-
25
B 115.7 8.6
---
DUCO Engineering, Inc. e
LOG OF BORING NO. 2 PROJECT NO. 9"-277
FJELD CLASS1FICATlON
Silty fine to medium sand -brown -firm -damp
90.7 Material becomes reddish brown in color and moist
FIGURE NO.
DUCO Engineering, Inc. e
DATE -DRILLED 12-28-79 LOG OF BORING NO. 3 PROJECT NO. 9-277
° A ~o... ~ ~ ~ ~ 0
th Dep
In
Feet
~~ q,'" ;:;.Cj ..,v ~o ~.,.... ~o~"" ~«¢(/ ° N A 'Y4I ~ ~v .$' '" A v"'>o ....,,'Y 'Y<' ~ ~~ O~ ~ -o'S. ..,-$' ~o O~ FJELD CLASSIFICATION Cj/'Y...." ° C;
Silty fine to medium sand -brown -firm -moist o
-~---_. --._".-.-.---~-------
Silty fine to medium sand -tan -firm to dense -
moist
1 C 109.4 6.8 83.3 ,---. ----.. --~. _. ---'"--._----~-.----* .. -------------. -_.-. --. -.-
Silty fine to medium sand -reddish brown -firm ,--moist
5 -
-
-
---
.;.
" i'''' ,
10 -
-
-
-
( -
15 -.
-
-
-
-
20 -
-
-
-
-
25
FIGURE NO. 4
DATE DRILLED 12-28-79
Depth
In
Feet
o
--.
1 B .
-
5 -
108.9 5.3 85.4
----.----.-------+---l
-
-
10 -
-
-
-
-
15 -
-
-
-
-
20 -
-
-
-
-
25
DUCO Engineering, Inc.
LOG OF BORING NO. 4 PROJECT NO. 9-277
FJELD CLASSIFICATION
Sil ty fine to medium sand ,.., brown --firm -moist
Material becomes reddish brown 1n color
~-I
. ';.~
-
FIGURE NO. 5
DATE DRILLED 12-28-79
Depth
In
Feet
o
-
.
-
5 -
1
---
-
-
-
10 -
-
-
-
-
15 -
-
-
.
-
20 -
-
-
-
-
25
A 109.8 6.3
------------
81.5
-----
DUCO Engineering, Inc.
LOG OF BORING NO. 5 PROJECT NO. 9-277
FlELD CLASSIFICATION
. Silty fine to medium £and -brown -fairly soft -
dry
Gravel leach line @ ·2 feet
Material becomes reddish brown in color -firm -
moist
FIGURE NO_ 6
Sob .ckey GeotecBAical
Incorporated
32145Via Carlos P.O. Box694
San Juan Capistrano, California
Duco Engineering
1170 Centre Suite F
Walnut, California 91789
Attention: Mr. Ron Cobine
(714) 496-6102
January 2~ 1980
Subject: Geologic Review of Proposed Carlsbad Tract 76-6, Royal Home~
No.7, Syme Drive at Chinquapin Avenue. Carlsbad, County of San Diego.
(Duco Engineering Project No. 9-27-7)
Dear Sir;
This report has been prepared at your request to provide geologic data
for design and construction of the subject tract in Carlsbad. Work for this
study has included an office review of pertinent published geologic literature"
fi.eld reconnaissance of the site, review of trench logs by Duco, and report,
preparation. This study has been based upon the 40-scale Grading Plan for
Carlsbad Tract No. 76-6 dated November 30, 1979.
Geologic Findings
The subject tract is considered to be geologically feasible for develop-
ment as planned, provided the recommendations of this and the s,")ils engineers
report are considered during construction.
1) No bedrock is present on or near the property. Eocene sands have been
projected at depth beneath the site. These are not significant to the development.
2) Surficial materials on the property consist of silty fine ~o medium grained
sands which have been designated as Quaternary terrace deposits. These materials
are probably marine in origin. They were-penetrated to depths in excess of ten
feet. The s~ds are quite massive. with no significant geologic struCture.
3) No geologic hazards, such as faults. landslides, mass wastage, accel-
erated erosion, soil slumps or groundwater were encountered on or near the
site. Ground rupture from faulting is unlikely qn the property. Nearby potentially
active faults include the South Coast Offshore Fault a few miles off the coast at
Car.lsbad and the more distant Chino-Elsinore Fault to the northeast. These
faults should be expected to host' earthquakes during the life of the structures.
With the relative distances to active faults and the known seismicity record of
this region, the _site is probably below average in its exposure to frequency and
Royal Homes -Syme live<Duco #9-277)
January 2, 1980
Page Two
. . severity.of ground shaking. Building design in accordance with normal Zone
3 seIsmic loading values is considere'd to be appropriate'.
4) Grading ,should be in conformance with recommendations of the soils
engineer. Further geologic input to this project is unwarranted.
Thank you for this opportunity to be of continued service. This study
has been conducted in accor'dance with generally accepted practice in the field
of Engineering Geology. No further warranty is 'offered or implied. Please
call (714) 496-6102 if there are any questions. '
Respectfully submitted,
BOB DICKEY GEOTECHNICAL INCORPORATED
EG914, RCE26945
Attachment: Topograhic Index Map
Dist: Or~ginal to addressee
BOB DICKEY GEOTECHNICAL
I
j
i i
',M
L < Royal Homes -Sym~rive(DUCO #9-277)
January 2. 1980
Page Three
TOPOGRAPHIC INDEX MAP
scale:
\
\
\ ".. \". ',' '~~i',
;;
Base map from a portion of San Luis Rey Quadrangle. USGS Floqd Prone Areas
Series~ 1971
BOB DICKEY GEOTECHNICAL