HomeMy WebLinkAboutCT 76-11; Tamarack Shores; Compacted Earth Fills; 1977-08-01Phase II Phase III Job Address: ENGINEER'S CERTIFICATE OF COMPLIANCE FOR COMPACTED EARTH FILLS Lots l-26 Lots 1-11 Lots 12-29, 36.46, 416 Tamarack Avenue Carlsbad, California ,/ Soil Testing Agency '-----~ Owner: Grading Plan by: FOLINDATION ENGINEERING CO., INC. 18344 Oxnard Street 996-1600 Tarzana, California GOLDRICH & KEST 4255 Fairfax Avenue Los Angeles, California 91356 PACE ENGINEERING, INC. 12517 Chandler Blvd. North Hollywood, California Grading Contractor: L. R. PAGE COMPANY, INC. 345-1523 4335 Marina City Drive Marina de1 Rey, California 90291 Date work started 617777 Date fill completed: 7111177 , 8/11/77 Note: See attached report for description of the grading, classification of the soil and tabulation of the test results. A Foundation Report describing the conditions at the site was prepared by Foundation En- gineering Company on October 25, 1973. Date of Certificate: August 1, 1977, September 1, 1977 I hereby certify that I have personally supervised the testing and inspection during placement and compaction of the fill described in this report, and on the basis of these inspections and tests it is my opinion that the work was done in full compliance with the Carlsbad City Building Code, the foundation engineer's report, and in general conformity with the approved grading plan. This certification does not include loca or dimensions of fills. FOUNDATION E N G I N E E R I N 416 Tamarack Menuc Carlsbad , Cal i l~or‘nia Phase I-Lots 1-26 Tract 231 Phase II-Lots l-11, 28-37 & 47-54, Tract CT 76-11 Phases III-Lotsl2-29. 36-46 Tract CT 76-11 General -acted fill was placed to providelevelbuildingsites, yardanzas and to provide proper drainage of the site. After remval of a septic tanknear JefferscmStreet, the excavationwas back- filled with axqxcted fill. The m depth of conpacted fill is about five feet, except in the septic tankbackfill area. Description of Fill Prior to placen-ent of the fill, the area was cleared of waads and debris. The loose natural soil was processed as reammended in the Foundation FQxxt. The natuml ground was scarified to a depth of six inches, mistened and compacted. After the ground surface was prepareditwas inspected and found take firm and suitable for support of the fill. Therraterial used for the fill was obtained fmm the site and inport and amsistedof silty sand, som ofwhichcontained rock fragn-ents. Fill was placed inlevellaxelayers ahout six inches in thickness,mistened tonear optimmmisture, and ampacted. Waterwas placedonthe corrpletedpr- t&m of the fill before placemnt of additicmal fill. All fill was placed in this-er and the topofthe fillwas sloped to drain towardthe street. The approximate extentofthe grading is shownan the attached drawing, "Lma- tion of Density Tests". The drawingwas prepared from a plan supplied to us. Testing Field density tests ware taken at freqmnt intervals near the fill surface. Representative samples of the soil ware taken to the la?mraizxy for WC- tion and classification tests. The relative density of the fill was deter- mined franthe compaction tests. Wheredensity tests~relow,additional rollingwas requastedand the area was retested. l%elccations of the density tests are given an the attached drawing showing the extent of the fill. lke results of the tests are shownon the table "Sumnary of Tests" , and a descripticm of the test nethods used is attached. FOUNDATION ENGINEERING c o., I N C; raeporton mtmlledmctedFil1 Phase I, II, III: 416 Tankxack Avenue Carlsbad, California 2 Conclusions and=- dations It is amcluded that the fill was placed in an orderly and efficient -er, that the field density tests are representative of the density of the fill placed, and that allporticols of the fill are compacted td at &east 90 percent ofthehdensity, detelmined in the laboratory in accordancewith the re- quirenents of the City of Carlsbad. It is vdsd that the provisions given in the Foundation RqxtdatedCcto- her 25, 1973, be used as abasis for design. Conditicr~s atthe sitewere similar to those anticipated in the original fomdation report. Ths soil is considered tobenczx%pansive. Ebctings on aqxcted fillshxldbe designed in accordance with the follming recomdations. Spread faAjngs should he desiqed for the allowable fou&ki~pressure set forth in the Foundation F+ Poe. In accordance with theFomdati~Fqort,avalueof2000 poundsper square foot rmybe used for acontinuous footing having awidth of12 inches andadepthof 12 inches. kinfor~trequirerrents, if any, for the floor slake skuldbe as determined bythe structural engineer. Continmus spread footings shouldbs reinforcedwith atleastone no. 4 bar of steel. 'Ibe topofthe flcor slab shouldbe above finished grade and the groundsurface shouldke sloped todrain away fromthe slab. FOUNDATION E N G I N E E f? I N G c 0.. I N C. LOCiTION OF DENSITY TESTS cc LL 0 - . Pl-/A’GE It Pi-l/XX T =a 45 . II -. 4 l 44 ,. -. . LEGEND 9* LOC. c NO. OF DEN5\’ LIMIT OF FILL 0s LA h I 4 L . . . - c ‘XPJIC TAhlK REHOWD -FROM -Ill15 ARER. TY -BT JEFFERSON ST: WASEL , TRAc‘T 231 4lLo TAUAlZPCIC AUE. c!a2LSc3AD , CAUE FOUNDATION ENGINEERINQ c o., I N C. LOCATION OF ENSITY TESTS l “3 PHA5E5 P C m lI?WT CT-7b- 11 411r, TRMARAOC AVE. CAEtL5SbAD, CALIF. EERINQ c o., I N C. Test NO. 1 . 2 . i 5 11 *12 ;i 15 21 22 23 ;: ;; 28 29 30 . 31 iz 34 35 36 3"; Date ---- 617177 6/7/77 6/7/77 6/7/77 6/7/77 Lot no ------'- 3 i 12 2 6/7/77 6/7/77 6/7/77 6/7/77 6/9/77 23 :; 14 32 (i/10/77 4 6110177 2 6124177 2 6/24/77 32 6/24/77 35 6124177 29 6/24/77 26 6/27/77 25 6/27/77 24 6127177 1 6/27/77 6128177 6128177 7/5/77 7/5/77 3 6 2: 16 715177 7/7/77 7/7/77 7/7/77 7/7/77 7/7/77 7/7/77 7/7/77 7/7/77 7/8/77 7/D/77 J/8/77 7/B/77 7/u/77 7/G/77 :: 11 2 1 2 i 6" SIJMI~ARY OF TFSTS .---------------- 416 Tamarack,Avenuc Carlsbad, California FIELD DENSITY TESTS _____-_________-_-- Percent Elevation Moisture -------- O.G. O.G. O.G. 0"::: FE 0:G: O.G. O.G. 2 FE 0:G: 0.6. O.G. O.G. : 2 1 F.G. F.G. FE: F.G. F.G. fi F:G . F.G. 2: F.G. F.G FOUNDATION E N G I N E E R I N G c o., I N C. 9 1;. 1: 10 5 1: 9 10 9 10 1;) 11 6 Maximum Density __--- - 129 129 129 129 129 129 129 129 129 129 129 No. 13 129 129 129 129 129 144 144 144 144 129 129 129 129 129 129 129 129 144 144 129 129 129 129 129 129 12 , 129 9 129 9 129 Degree of Field Phase Compaction HO ~_ ------- Density ----- - ---'-- 91 117 I 91 117 I 91 117 I go 116 I 91 117 II 94 121 93 120 93 120 90 116 91 117 96 81 91 % 124 105 117 118 116 31 90 92 90 93 iii 92 91 91 ;: 91 91 95 ;: 92 ;: 94 92 ;; 91 117 116 133 130 134 134 127 118 117 117 118 it; 117 137 133 117 118 121 124 121 118 123 118 117 I I I II I I I II II II I I : I I I i I I I I I I I I I I I I I Summary of Tests 416 Tamarack Avenue Carlsbad. California Test No. Date 4"; 4% 49 50 :: *53 54 55 56 :; 65: 61 :: *64 65 66 67 ifi 70 . :: :i 75 76 :i 79 80 7111177 7/11/77 7/ll/77 ::g:: ::; i::: 7/ll/77 7111177 7/ll/77 7111177 7/ll/77 7/ll/77 ::'11::: 7112177 ::; y:: 7/12/77 7/12/77 7/15/77 7115177 7115177 7126177 7/26/77 7126177 7/27/77 7127177 ::::::: 7130177 7130177 7130177 7130177 7130177 :::i::: a/ l/77 af 1177 a/ l/77 Lot No. Elevation F.G. K: 2: E: :t F:G: :*:* F:G: 2: 2: :; 31 O.G. x* 0:G: 1 1 : E: i ;: 11 7 E: K 1 :::: :-ii- 0:G: :i 9 :: O.G. F.G. 1 ; FOUNDATION E N G I N E E R I N G c 0.. I N C. Percent Ilaximum DerJree of Field Phase Moisture Densitv Compaction Density J& 129 129 131 131 131 120 117 122 123 124 11 129 7 129 8 144 6 144 5 144 120 116 133 130 130 11 10 ii 9 129 129 No. 55 129 129 118 121 112 117 116 7 1; 10 9 129 E 129 129 118 121 117 121 120 129 129 129 No. 112 129 117 117 83 107 91 117 117 125 128 127 118 1: 10 1; 9 7 1'1 11 129 129 131 131 129 129 129 129 129 129 131 129 131 , 131 131 91 9': 9": ;i ;: 91 z: 91 ;: 120 121 123 117 117 119 118 119 124 119 : I : : I I I I : : 1:: III III II :i :I II II III III II II :I if II III II 1:; III 2 Sumnary of Tests 416 Tamarack Avenue Carlsbad, California Test No. Date Lot No. i: 83 84 85 a/ i/77 ij :::: 81 2/77 81 2/77 81 2177 8/ 2/77 8/ 2/77 a/ 3177 af 3177 91 ;: 94 95 81 3177 !$ :::: 8/ 3177 a/ 3/77 9967 ;i 100 a/ 3177 a/ 3177 a/ 3/77 af 3177 af 3177 101 102 103 104 105 a/ 3177 a/ 4177 af 4/77 i$ i::: 106 a/ 5/77 107 a/ 5177 108 a/ 5/77 109 81 5/77 110 a/ 5177 *111 112 .*113 114 115 81 a/77 af a/77 8/ 8177 af a/77 af 9177 116 a/ 9/77 *117 af 9/77 118 af 9177 119 81 9177 120 8/11/77 iz :i 34 :65 37 38 39 17 30 3: 19 Elevation Percent Maximum Degree of Field Phase Moisture Density Compaction Density No. 2 : ::GG: ::GG: :::: F.G. F:GG: :-Es F:G: F.G. 3 5 2: 12 ;: 1': :*t* F:G: E: 11 1: 2 K FIG: ::GG: :2 F:G: : 8 E: 1: 131 131 131 131 131 131 131 131 129 129 129 129 129 129 129 131 131 131 131 131 131 131 131 131 131 131 129 131 129 129 No. 115 129 No. 116 129 129 129 No. 121 129 129 4 129 z: ;; 94 zi z: 95 91 z: 93 93 ii66 iizi 92 95 ii: i: ii: ;: 94 i: 9": 90 91 9": E 3 122 122 120 128 123 122 122 121 121 123 117 117 118 120 120 126 126 120 123 121 124 120 121 120 119 122 120 122 117 121 110 117 110 116 116 117 106 117 118 124 III III III :I III III :t II 1:; III III III III III III III III III II :: III III :I II II :I :: 1:; III III III FOUNDATION E N G I N E E R I N G C 0.. I N C. Summary of Tests 416 Tamarack Avenue Carlsbad, California 4 Test Percent Maximum Degree of Field Phase No. Date Lot No. Elevation Moisture Density Compaction Density No. 121 iii:;;::: ;: 129 124 III 122 E 1: 129 z; 118 III 123 B/11/77 27 F:G: 9 129 91 117 III *Test failed. Additional compaction was requested. See test number in Max. Den. column for number of satisfactory retest. FOUNDATION E N G I N E E R I N G c o., I N C. SUMMARY OF TESTS ---------I 416 Tamarack Avenue Carlsbad, California COMPACTION TESTS -----II I II Maximum dry density, pcf: 129 131 Maximum size tested: #4 x4 Optimum moisture, percent: 9 10 CLASSIFICATION TESTS I II Soil type: Silty Sand Silty Sand Silty Sand % passing no. 314 sieve: 100 % passing no. 4 sieve: 100 % passing no. 200 sieve: 42 % passing no. 270 sieve: .33 Plastic Index: Slghty. Pls. EXPANSION TESTS - -------- I Surcharge Load, p.s.f. 60 Expansion, percent: 1% ;: 45 36 95 si 32 Slghty.Pl' Ron-Plastic ii III 60 1% 1 2 III 144 314" 8 III FOUNDATION ENGINEERING c o., I N C. TEST METHODS FIELD DENSITY TESTS Field density tests were made by the sand volume method in accordance with the American Society for Testing Materials (ASTM) Test Method D 1556. The density was determined by obtaining the dry weight of the soil from a hole approximately eight inches deep and determining the volume of the hole with calibrated sand. COMPACTION TEST The maximum density and optimum moisture content were determined in the laboratory in accordance with the American Society for Testing Materials (ASTM) Test Method D 1557. The compaction test was made in a four-inch diameter mold having a l/30 cubic foot volume, with 25 blows of a ten- pound hammer falling 18 inches on each of five layers. A new batch of soil was used for each point on the compaction curve. CLASSIFICATION TESTS Classification tests were made in accordance with American Society for testing materials (ASTM) Test Method 2488. The No. 4 sieve has 3116 inch openings. The largest particle that will pass a No. 200 sieve is about the smallest that can be seen with the unaided eye. Gravel is that frac- tion larger than the No. 4 sieve; sand is the fraction that passes a No. 4 sieve and is retained on a No. 200 sieve. The fraction passing the No. 200 sieve is a silt if non-plastic and a clay if plastic. EXPANSION TEST The expansion index test is in accordance with the Uniform Building Code Standard No. 29-2. A moistened sample was compacted in a four inch dia- meter ring with 15 blows of a 5.5 pound hammer having a fall of 12 inches per inch of compacted sample. If the degree of saturation ranged between 49 and 51 percent for an assumed specific gravity of 2.7, the specimen was loaded with 144 pounds per square foot and flooded. After 24 hours the expansion was noted and the expansion indices calculated. FOUNDATION ENGINEERING COMPANY