HomeMy WebLinkAboutCT 79-26; 17 UNIT CONDOMINIUM PROJECT; PRELIMINARY SOIL INVESTIGATION; 1980-08-22••
PRELIMINARY SOIL INVESTIGATION FOR THE
PROPOSED 17-UNIT CONDOMINIUM PROJECT
IN CARLSBAD, CALIFORNIA
•
Augus t 22, 1980
Project Number -00051
Prepared for:
Thomas & Sowards Engineeri~g, Inc.
21 5 S. Hwy 1 01
Suite 101
Solana Beach, CA 92075
Prepared by:
Torrey Pines Consu1ting
'J.a5 V; a de-}a-\fatTe
TORREY PINES CONSULTING
I 2145 Newcastle Avenue
• Cardiff·BY·The·Sea, CA 92007 , .
August 22, 1980
Thomas & Sowards Engineering, Inc.
215 S. Hwy 101
Suite 101
Sal ana Beach, CA 92075
•
Subject: Preliminary Soil Investigatian far the
Proposed 17-Unit Candaminium Praject
In Carlsbad, Califarnia,
Legal Descriptian: Lots 387 and 388 af La Costa South,
Unit No. 5 accarding to map no. 6600.
Gentlemen:
In accardance with yaur request, we have perfarmed a Preliminary ,S6il
Investigatian at the subject site. Our investigatian was perfarmed
to. pravide preliminary geatechnical data to. ,aid in averall site planning
and develapment. This repart presents the reuslts af aar fteld and
labaratary investigation, as well as gealagic and soils engineer-ing
ana lysi s, whi ch are the basi s for aur findings, co.ncl uS'i ans and r.ecammenda-
tians.
If yau shauld require any clarification of the abave, dan't hesitate to
gi ve us a ca 11 .
Very truly yaurs,
TORREY PINES CONSULTING
Dennis E. Zimmerman, P.E.
C26676
Praject Engineer
DEZ:mh
i
,Dan D. GaaQwin
Praject Manaqer
TABLE OF CONTENTS
Letter of Transmittal
Tabl~ of Contents
Introduction
Layout of Report
Scope of Services
Proposed Development
Site Description
Location Map, Plate No. 1
Geology
Regional Geologic Map, Plate No. 2
Field and Laboratory Investigation .
Site Plan, Plate No.3
Site Photographs, Plate No. 3A
Conclusions and Recommendations
Limitati ons
Appendix A -Subsurface Investiga~ion
Exploratory Test Pits, Tl -T6
Appendix B -Laboratory Testing
Unifi ed Soil Cl assifi cati on Chart
Tests Results
Appendix C -Recommended Grading Specifications
ii
•
i
; ;
1
1
1
1
2
3
4
5
6
7
8
9 -15
16
17
18 -23
24
25 & .26 ..
27 & 28
29 -31
INTRODUCTION
•
PRELIMINARY SOIL INVESTIGATION FOR THE
PROPOSED 17-UNIT CONDOMINIUM PROJECT
IN CARLSBAD, CALIFORNIA
The report presents our nplnlons resulting from our soil investigation
on the subject property. Our i nvesti gati on was perfo'rmed on ft.ugust 12,
1980. The purpose of this investigation was to evaluate the site from a
geologic and soils standpoint and to provide preliminary recommendatiolls
for your use in overall development.
LAYOUT OF REPORT
The body of the report contains the text of our findings and ·r.ecommend~tions.
Details of our field and laboratory work are presented in the appendices
at the end of the report. Key statements in the test are underl ined..
SCOPE OF SERVICES
The scope of services performed in the course of this investigation inclUded:
1. Review of published and unpublished reports and maps pertaining
to the subject site and its vicini'ty;
2. Geologic mapping 'of the site;
3. Subsurface exploration consi~ting of six backhoe pits~
4. Laboratory testing of representative soil samples obtained dllring
the field investigation;
5. AnalysiS of field data and preparatiori of this report, including
our findings, conclusions and recommendations.
PROPOSED DEVELOPMENT
Proposed development of the irregular shaped site is for 6 buildings
comprising a total of 17 condominium ~nits. Structures will consist
of two stories of wood-framed construction over ·a first level 'par,king' garage.
The parking garage will utilize both 'wood-framed and concrete. masonrY unit
construction.
-1-
, .
SITE DESCRIPTION
The subject site is located on the east side of Romeria Street, north of
La Costa Avenue and south pf Gibraltar Street in the La Costa a~ea of the
City of Carlsbad, County of San Diego, State of California.
The subject site has previously been graded into two separate 10ts, the·
southern lot being about 15 feet higher than the northern'lot: Both lots
are flat, with cut and fill slopes surrounding each.
A condominium complex exists to the south of the site, about 15 feet higher
in elevation than the adjacent subject site. A housingsubdivtsion is
present to the east, standing atop an approximately 60 foot hign slope ..
To the north are located vacant graded lots. Romeria Street borders on the
west.
Geographic relationships are shown on the Location Map, Plate No .. 1.
The site consists of poorly compacted material. Both pad~ are cut/fill
pads with fill extending to 171-611 below existing pad grade for the southerH
lot. Running water was encountered at various depths on both lots.
-2-
LOCATI·ON MAP
17 (/.),'nl:.i C.oniu.fUng --' 0 'ttl:. !:J ;..I"
ROMERIA STEET CONDOMIN"IUMS
PROJECT NO. ,D,ATE PLATE
I 00051 8-22-8.0 NO, 1
-3-
GEOLOGY
The subject site is located in Carlsbad, California.
Underlying the site according to the U.S. Geological Survey Map,
San Diego Quadrangle, are Eocene marine sedimentary rocks of the
Tertiary Age. .
No faults are known to pass through or near the site.
The Regional Geologic Map, Plate No.2, shows the subject site and the
geologic setting of the area.
-4-
\.
\ \ "-\ \ \
'''' •. 1
Scale=1:250,OOO
~, I nUIII
\.Inrt
REGIONAL GEOLOGIC MAP
RnM~RIA STREET COND0MfNIUMS
PROJECT· NO. DATE PLATE
0005.1 8-22-80 NO.·?
-5-
,
I
. !
FIELD AND LABORATORY INVESTIGATION
The subsurface investigation consisted of 6 test pits trenched to a
maximum dpeth of 19 feet. The locations of the pHs are shown on the
attached site plan, Pl ate No.3. The trenches were carefully logged
and sampled by our personnel. Site photographs are shown on Plate No.
3A.
Represenative samples of the various soils encountered in the trenches
were returned to the laboratory for evaluation and approriate testing.
Logs of the test pits and descriptions of the laboratory tests are presented
in Appendices A and B, respectively.
-6-
./
\~
Vacant .Lot
\ ,
\
\
\ I
I)
Existing Subdivision
----1: __
\
Existing
Condominiums
, . ;".....-. ".
I
I ~ -::..J I
I
r:::::=ll I I
T1 ,\
\
( --. ,--.,\.,
I~T4 \' ?/---" 1/ --. --...
Romer'ia Street
r::::::::J T6 = Approximate location of test pits.
SITE ,P.LAN
ROMERIA STREET CONDO~INIUMS
PROJECT 'NO. DATE PLATE
~------------~--~--~----~ 00051 8-22-80 NO.
7' --
3
POOR
QUALITY
ORIGINAL ·.S
Southerly lot looking southeast
at southern fill bank.
Southerly lot looking east.
, .
S I FE PHOTOGRAPHS'
, RO~ERIA STREET CONDn'~pWIf'<1S
PROJECT NO. DAre: PLATE
f----------~~4-----~~--~~
00051 8-22-8,0 NO. 3/\
-8-
CONCLUSIONS & RECOMMENDATIONS
A. General
The site is suitable for the proposed'development from a peoloqic
and soils engineering. standpoint, with,in th~ f.ramework of our
recommendations. There are, however, certain constraints whic~.
must be taken into account. The contraints, conclusions and
recommendations follow.
B. Slope Stability
We recommend that any required permanent cut or ,fill,slopes be
constructed to an inclination no steeper than 2.0 horizon'tal to
1.0 vertical. Also, all existing slopes within the ptoject site
should be reduced to 2.0 to 1.0. Placement of fill near the tops
of slopes should be carried out in such a manner as to assure that
loose, uncompacted soils are not sloughed over the tops and allowed
to accumulate on the slope face.,
The on-site soils will be highly susceptible to erosion where
exposed on slopes. Therefore, the project plans and Specifications
shoul d contain a 11 necessary features. and constructi on requi rements
to prevent erosion of the slopes both during and after constructidn.
Slopes 'and other exposed ground surfaces should be approp'riately-
planted with a protective ground cover.
C. Gradinq and Earthwork
1. Clearing
Prior to. gradinq, the site should be cleared of s'urface
obstructions and stripped of brush and vegetation. Obstructions
which extend below finish grade should be remov,ed .and ,replaced
with compacted fill. Vegetation and debris from the 'clearinq
operation should be removed from the sfte.
-9-
2. Existing Fills and loose 'Natural Soils
Any existing fil,l material and loose natural soil that is not
removed by the required site excav'ation work 'should be over-
excavated down to firm natural ground and replaced as compacted
fill. The need for and extent of over-excavation work to
remove existing loose materials should be determined by the' $oil
engineer in the field during the site preparation work. The
minimum depth of removal shall be 5 feet below exjsting g.r.ade.
This minimum dej)th of removal is necessary because of the Tow
strength of the existing soil material due to the following factors,
(1) portions of the existing fill is less than the required 90%
relative compaction and (2) the onsite soil is critically ~xpansive,
causing severe cracking from shrinkage and expansi'on during wetting·
and drying of soil materials.
3. Scarification and Processinq of Surface Soils
Fol10win~ over-excavation of unsuitable materials, all areas
of the site to receive fill and/or other improvements should
be scarified to a depth of 6 to 8 inches, brought to near
optimum moisture conditions, and compacted to at least 90
percent relative compaction.
4. Ri ppabil i ty
The on-site soils and bedrock materials are' expected to be
excavated using conventional earth-moving equipment.
5. Over-excavation of Transition {Daylight) Pads
If a dayl i ght pad shoul d occur where the building \>li.11 'p"3.rtly
be underl ai n by compacted fill and partly by bedroc'k and/or
-10-
natural soil, the cut portion of the lot should bp-over-
excavated to a depth of at least 4 feet below finished,
pad grade and replaced with compacted fill.
6. ~1aterial for Fill
All existing on-site soil and bedrock materials ~re suita~ls
for reuse as fill. Fill materials should, in general, not
contain rocks or cobbles greater than 6 in6hes in largest
'dimension. However, larger rock fragments may be incorporated
into the lower portions of fills, provided the method of
spacing and compaction is apr roved by the soil engineer.
7. Compaction and Method of Fillina
All fill at the site should be comoacted to a minimum relative
compaction of 90 percent, based upon ASTM Laboratory Test
Oesiqnation 0-1557-78. Fill ~hould he compacted by mechanical
means in uniform li~ts of 6, to 8 inches in thickness.
Fills constructed on natural slopes ~aving an inclination
steeper than 5 horizontal to 1 vertical should be keyed and
benched into bedrock or competent natural ground.
Compaction of slopes should be achieved by overbuilding, the
slopes laterally and then cutting back ~o the design line and
grade or by back rolling with sheepsfoot at'frequent intervaJs
as the fill is placed, followed by final rolling of tbe entire
slope. Feathering 'of fill over the tops of slopes should not
be permitted. /l.ll fills should ~)e ~laced am! grnding pe,rformed
in accordance wit~ applicable local gradinq ordinances.
8. Trench Backfill
Pipeline trenc~es should be backfilled with compacted fill.
Backfill material should be placed in lift thickh~sses armropriate
to the type of cOf11paction equipment utilizet;! and, comoacted to
90 percent bv mechanical means.
-11-
9. Drainage'
Due to the excessive running water found es~entia11y at all depths,
including the contact line between the fill and form~t;Qnal s.oi1
rna teri a 1 and due to the fact that the site is located on a natural
drainage course, we recommend that a french drain system. be inst~lled
at the site.
The french drains should be installed behind th~ retaini·ng wall footings,
extend a minimum of six feet below the retaining w?\ll footings, be
continuous to and drain into the street, have a minimum 3% fall and
be a minimum of 18 inches wide. At the bottom, place a 6 inCh ~iameter
perforated rigid pipe with the perforations facing· down wi.th a minimlJm
of 6 inches of gravel surrounding the pipe. Th~ last 20 feet of pipe
at the outlet shall be non-perforated pipe. The french drain sha11
be backfilled with Class 2 permeable material.
Positive surface gradients s·hould. be provi~ed adjacent to buildings
so as to direct surface water away from foundations and slabs toward
suitable discharge facilities. 'Ponding of surface water should not be
allowed adjacnet to structures or on pavements.
Water should not be allowed to drain over slopes.
10. Recommended Gradinq Specifications
Grading should be done in accordance with Appendix C, "Recommended
Grading Specifications."
D. Foundation and Slab RecommendationS
1. ~ecommendations for Expansive ~oils
Field observations and laboratory testing indicate that the
expansion potential of the finished pad soils will be in the
critically expansive range.
Recommendations for foundation and slab design, cons;rl~rinq
the expansive soil conditions, ar~ as follows:
-12-
a) All footings should be 24 inches deep below
slab subgrade, continuous, and contain 1 -Nb. 5
bar top and ,bottom.
b) Living area floor slabs s~ould be a minimum of 4
inches thick with 6X6-6/6 welded wir~ fabric at midh~ight
over 1 inch of sand over 6 mil visoueen moisture barrier dver
four inches of gravel or sand base.
c) Garage floor slabs should be 4-inches thic'k \,lit.,: F.X'6-f./6
\'/e 1 ded wi re fabri c, i so 1 ated from stern \1a 11 footi ngs, oyer
four inches of gravel or sand base. No moisture nar'rier .is
required.
d) Pre-soak under all slabs, to a depth of 24 tnches to 3%
+3% above optimum moisture content . .=-•
2. Soil Bearing Pressure
Structures may be supported on conventio'1a1 shallow footings' '
bearing in bedrock, firm natural ground or compacted fill. At,
a minimum depth of 24 inches for two or three--stdry buiTdi"ngs"
footings may be desi!J.ned for an allowable .de'ad plus li:ve load
bearing pressure of 1200 pounds per sq~are foot.' Th~Se
va 1 ues may be increased by one-thi rd for short-term loads, ,
including wind or seismic. Footings should have a mini~um width,
of 12 inches.
Settlements under buildinq loads are ~xpecterl to be w1thin
tolerable limits for the proposed structures.' We estimate that
post-construction differential settl~ments across anyone
building will not exceed 3/4 inch.
3. Lateral Loads
Lateral load resistance for the buildings and retaining \'/811s .'
supported on footing foundations may be deveioped in fdctiqn
between the foundation bottoms and'the supportinC"f s\.Jbgra·d~.An
allowable friction coefficient of 0~30 is considered applicable.
An additional allowable passi.ve uniform pres'sure of .500 pounds
-13-
per square foot acting against the foundations may, be used in
design provided the footings are poured neat against the adjacent
compacted fill materials or undisturbed natur.al soils.
4. Retaining Halls
We recommend that retaining walls be constructed adjacent to the
southern and eastern slopes. The southern wall should be sUffie~tly
high so as to reduce the slope to a maximum inclination of 2.0 to
l. 0, hori zonta 1 to vert; ca 1 uni ts, from top of wa 11 to 'top of slope.
The eastern wall should be suffiently high ~o as to reduc~ the slope,
inclination to a maximum of 2.0 to 1.0, horizontal to vertical units,
from top of wall to the existing gunite ditch.
Retaining walls must be designed to resist lateral earth·
pressures and any additional lateral loads caused by surcharge
loads on the adjoining slab surface. We recommend that
·unrestrained walls be designed for ,an e~~ivalent fluid pressure
of 35 pounds per cubi c foot (pcf). He recommerd that res tra i ned,
walls be designed for an ~quival~nt fluid pressure of 35 pcf plus
an additional uniform lateral pressure of 5H pounds per square
foot where H = the height of backfill above the top of the wall
footing in feet. Wherever walls will be subjected to surcharge
loads, they should also be designed for an additional uniform
lateral pressue equal to one-third the an~itipated surcharge
pressure in the case of unrestrained walls and one~half the
anticipated surcharge in the 'case of restrained walTs.
The preceding design pressures assume that there is s~fficient
drainage behind the walls to prevent the build-uD of , hydrostatic
pressures from surface water infiltration. AdeQuate drainage may
be provided by means of weep holes with permeable material installed
behind the walls or by means of a system of subdrains'.
Backfill placed behind the walls should be compact.ed ,to a minimum
degree of compaction of 90 percent using light compaction equipment.
-14-
•
If heavy equipment is used, the walls should be appropriately
temporarily braced.
Retaining walls should be supported on footing foundations
designed in accordance with the reconmendations presented previously
under Item 0.1 "Recommendations for Expansive Soils'." Lateral load
resistance for the walls can be developed in accordance with the
recommendations presented under Item D.3, "Lateral Load Resistance."
If you should require any clarffication of the above, don't ~esitate to give
us a call.
Very truly yours,
TORREY PINES CONSULTING
Dennis E. Zimmerman, P.E.
C26676
DEZ:mh
. -15-
Dan D. GoOdw,i n
Project Manager
'e
LIMITATIONS
Conclusions and recommendations made in this report are based on the
assumption that the soil and geologic conditfons do not deviate apprec~
iably from those disclosed by the test pits. If vari·ations are encountered
during construction, TORREY PINES CONSULTING should be nQtifi~d so that
we make supplemental recommendations if.this should be required.
Evaluation of soil materials for support 'of structures incTudescontinUous
inspection during grading. The soil engineer should continue his services
through the inspection of grading, including construction of ~}ls, founda-
tion eicavations, trench backfill, backfill behind retaining walls and
installation of the french drain system.
-16-
, . "
APPENDIX A
SUBSURFACE INVESTIGATION
The investigation was continuously supervised, excavations logged and
samples obtained by this firm for labor~tory testing. Logs of the
borings are presented with this appendix.
-17-
. . EqIJip men! Dimension Test Date
580 C Case B.ackh,oe 24" Auous,t i'2 J9RO
Surface Elevation Groundwater Depth " Logged by ,
Ex.;st;ng Grade 17'6" D.Z.
DESCRIPTION a CLASSIFICATION '\H ~ WATER IN-PLACE
IC~NE-NT DRY
DENSITY , '
DESCRIPTION .,,~, REMARKS COLOR CONSIST. ITYPE SYM. ft. :.r 0/0 pef. -... ,
C1.ayey fine sand (Fi 11 '-Brown Medi,um SC ~ . : " .. '-Humi,d .:. ~ .... t.
iDe,nse, ::' ,'::.: -Clayey fine sand CFnl) Brown !Med SC I':::: ;: ' Moi st ~; .. ~ .::.-f-Dense ....... r', ~ '. : I-I~:; " .:: . . • , !. '"
!. : .... : f-
i-.:'.:
Silty fine sand (Fill) Grey an< Medium SM .;: .: " Mo.i st
Orang; s~ Dense .:.,\~ -
Brown ':';~:.;: -
Mottled , 1. ....
~;.:~.~. --
I-~: : .. : : . ; ....... ~ .... ..... ,,'" : ", : ...... .--.:, '::",'" ........... -t::~;} -7 ... . " .... .. : .... : : ~ ::.~: .. ~:. .
I-~
., .... . :._.::. ••• : i f-·: .. ::.r.;·: "'~'" ....... """ :.:"'::"':-:~ -.: .. ,~~.~
~;.:~. f -:-10 I'~ "-' . I ....... :,:,~ --•... : :.:. J" "
Silty fine sand with cobb1 ~s Light ,r~ed; urn SM I'~':'F:::~' I-Moist
(10% to 10") (Fi 11) Brown, Dense t~iH\ f-12· White
and -:~:: ::!::. I-
Orange f'~'~~~ '1/3.
}'ottl eo .' "1 •• ~ --:1 ::;~.
~:~~tura 1 Ground) .:.;:'!.":. -/4
19' ) Light Dense SM '<Z ttom of Trench -.. " t
Slightly silty fi'ne sand Brown '. ~: -' Running water, 17' 611 .... V Satura :ed
EXPLORATORY TEST Pit .LOG
C!OUF.Y fiJlnt.1 COn.iU.Ltin.g ROMERIA STREET CONDOMINIUMS
t
PROJECT NO. ,DATE LOG·
00051 8-22.,.80 N.O. T1
-18-
.
Equlpment Dimension Test Date
580 C Case Backhoe 24" August 12, 1980
Surface E/~'~~/c,,; Groundwater Depth L ,',,';',..L>.;.! by-,"'!:n:/"IJ
Existing Grade 3' -Su5surf~ce Woter DZ
DESCRIPTION a CLASSIFICATION 1\ I WATER IN-PLACE
IC~NENT .. DRY
DENSITY
DESCRIPTION ·"14, REMARKS COLOR CONSIST. ITYPE SYM. ft. E .0/0 pet; .'
S1i-ghtly silty-fi:ne sand '.', .', Light Loose ... '" .. S~1 Damp .-.... -· (Natural Ground} Brown . . ' .• : -I:.
Sl; Iht1y silty medium sand L i Iht Medium " ',:~:, S~1 Moist ·or ........ f-Brown <to •• " •• , ~ .... :. . .
I " f--. , . . .,. .. " .: .. " . r-· : :: :.
Clayey fine to medium sand Orange, Dense I:~~$ SC -Satura ~ed
with rock (20% to 16") Iron ,0Q~ f-
(Free FLowi ng Water) Stai'ns very ~:;: ;:: SM :Slightly sil.!¥. medi'um sand Dens.€. .. .. .. r-· wjth rock (20% to 16") :* ••• ':: .:. .... :'0< .. .. ': '-' ... -.... :
t{·; -... 6·~:)· -
-!{~.{~{ -Moist . .. I-{~~:q '.... '.
~.~tl ....
-
:"C}' -16(' -IO~ . ,.I}~ (Near refusal with backhoe f-
I .... ,
f-. 'l· ,Bbttom of Trench -11' 6" :a:: ~ .. :.::". ,
-I. -
-13· -
-14· -
-15·
I-
.EX~LORATORY TEST P.lT .~OG
C!o'tuy fP£n£.fI. (!onfl.u[t£n9 ~ RDr1ERIA STREET CONDOMINIUMS
PROJECT NO. DATE' LOG.
0.0051 8~22-80 NO~ T2
-19-'
Equip men!
580 C Case B.ackhoa
Surface Elevation
Existi"ng Grade
Di"1t!7s;or
2.4 II,
Groundwdt Depth
N/A
Tes.t Date
Augus,t 12, 1980
Logged by
DZ
DESCRIPTION a CLASSIFICATION 1\ IH
WATER IN-PLACE
ICON-DRY
TENT DENSITY
DESCRIPTION '''~r REMARKS COLOR CONSIST. ITYPE SYM. ft. i= % ' pet "-
Sl i ghtly silty nne sand,
(F.il U
Clayey fine sand, (Fill)
(Bottom of Trench = 10 1 )
Light Loose
Brown
DarR IMedi'um
Brown iDens'e-
Layered
wHir
Orangi.sJ
Brown
S~1 rrn::::~ f-Damp
I~: ~.:
:..
_ r /_
f-
f-/.
I-
1-13.
f-f4
1-.
1-/5-
~.
" , .
EXPLORATORY' TEST PIT .LOG
ROMERIA 'STREET' coNDOMTNIUr~s
PROJECT NO. DATE . LOG,
~---------------4------~----~ 00051 8,..22-8n NO. ' T3
-20-
,..--m;;;;:;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;:;;;;;;;;;;;;:;;;;;;;;;;;;;;;;;;;;;;;;;l Equip men!
580 C Case Backhoe
Surface Elevation
EXistinq Grade
Dimension
24"
Groundwater Oepth
N/A '
DESCRIPTION a CLASSIFICATION 1\
~tesi Oot'f/
August 12., 1 980
LogQf1d by
DZ
WATER IN-PLACE ICON~ .DRY
TENT DENSITY
DESCRIPTION 'If~,. REMARKS COLOR CONSIST. [TYPE SYM. ·.ft.. ~ % pet. :.;.
Slightly silty fine sand, Light
(Fill) Brown
!) /1 ~ht fy s 11 ty fi ne sand Dark.
(F)11) Brown
'Loose
Medfum SM
Dense
Sligh'tly silt fine sand,
(Fi 11 ) Orangish Medium SM Grey Mottled Dense
Damp
Motst
Moist
EXPLORATORY TEST P·IT .LOG
PROJECT NO.
0.00.51
-21-
DATE' LOG·
NO. T4
Equip men!
580 C Case Back~o~
Surface Elevation
Existing Grade
Dimension
24 1t'
GrVVfluwuter Depth
21 Subsurface Water
'O£SCRIPTION a CLASSIFICATION 1\ 'H
Test Date
8:..;l2~8n
L';!:I!:Ir:TI.,t, by
DZ
WATER }N-PL,.ACE
CON-
TENT DE'NSITY
DESCRIPTION H!4,. REMARKS COLOR CONSIST. TYPE SYM. 'ft. ~ 0/0 pct.
Slightly silty fine sand, Light Loos e Sr·1;' ":~':. f16i s t .~ .•• I--(Natural Ground) Brown '. I ::'!~: 1--.
' . .. ; .......
Slightly'silty medium sand Light Medium S~,1 ~::'::~
r-_ru_n:....ri __ iin~lg:....w_a_t_er_@_2_' ___ -I-G_r....:ey::....--I-_D_en_s_'e-+_-k:~~ .. ~.\:.;I--.
'Slightly silty fine sand Light Medium SM '*r
(Bottom of Trench ~ 91)
Brown Dense 1":'-;:1-
: .. ~:: ~
: .~~.::. ~ I:·::· .::. -
.' ' _: :. ~'. I--
; ..... :::' roo < .. " .... 1-.: : '.~. I--..
.... :".
:: ).::}J-.. ,., ..
~:<::.I--7
" ...... t.
;-.. ,. l-
•• tI ...
:. :··l.~ ~
." " ·10" ~ •.... ':t-. ~: : '.,
-10-
'--
I--.
1-12,
I-
1-13.
1--/4·
I--.
1-'5--.
Noist
to Satura~ed
Noist
~XPLO'RATORY TEST PIT ,LOG
Ror1ER.~A STREH· CONDOtWNI1JMS
PROJECT NO. DATE
O.Q05l
-22-
LOG,
NO. T5
£qulp ment Dlmenslon Test Date
580 C Case Backhoe 2411 August 12,,1980
Surface Elevation Groundwater OeptiJ , Lvyyr;d by
Existing Grade N/A ' D.Z., .
DESCRIPTION a CLASSIFICATION 1\ .~'~~~:RIN-~~~ti:: ~ ________ ~ __ ~_~_.~~~I~H~· ~ENTDEN~tY
OESCRIPTION "'Ur REMARKS COLOR CONSIST. SYM.TYPE :ft .. ~ % .. pcf.
Sl i ght1y si 1 ty fine sand Dark Loose ::~~5 SS---~ Damp
~(~'F~iJ~JJ~ ___ ~~-+~B~11r~own-r~~~~'_'Y/' -I~~~-r--~~~--~
C1 ayey fi ne sand (Fi 11 ) \~hi te Medi urn I':: -=-/1 SV i\ Moi s t ~~~ ______________ -r ____ ~~D~ens~;e-¥,.~~~·"~,<,I/~ F-,\~, ____ ~ __ ~ __ ~~~~
Sii.ght1y silty fine sand Grey & Medium .. ':''':'' '-
(Fi 11) Orange Dense .:.~:.:. -. ~/~m~ . ~:::3V=3 '\. r-S:::l:'":'i~g h~t'":'l-y -s-:'i 7"lt-y--:"f,:-"' n-e-s-a-n d-:--~L:.J..a':':':.Ye:.!.-'! r~ec--:-:--Hed-:-:' i~u-m +':::~';:'.~::.'~ S C _ "1-:-:~'1:--ol~'·: s""'-:'t-+-----.,.-.,..--+----.....o.-t
(Natural Ground) Grey & Dense ; :::,,:
(Bottom of Trench -10')
I ••• Oral'}ge .. ::':::;'
~\~.::.~
~: .... <11 ~ ..... ,'\
."'*,* ',', '''', .~".f.
:/. I. ~ '0 •
• : to -: .. *. ... .-: > .
•• " I 'w~ .', :"'. #.,. ': .. ' ... '''.
.,"" 'f
.. ' .. -.
-
-6 --
~
i"'" ---
F-
r-, -.
-12· -.
-13--
:"'14
I-
f-IS·
i-" •
EXPLORATORY TEST Pl-T.LOG
"RO!1ERrA S.TREtT CONDO~tNriJnS
PROJECT NO.
0.Q0.51
. -23-
DATE LOG.·
NO. T6:
-.
APPENDIX B
LABORATORY TESTING
Sails were classified visually according to the Unified Soil ClaS5~
ification System. Soil classifications are shown on'the Logs of
Borings attached to this report.
Mechanical analysis, natural densities and moisture contents were
performed on representative soil samples.
In addition, maximum densities and opti"mum moistures were performed for
typical soil materials.
Also, the angle of internal fri'ction and cohesion were determined for
representative soil samples.
Laboratory test results are attached.
"-24-
"
UNIFIED SOIL CLASSIFICATION CHART
SOIL DESCRIPTION
I. COARSE GRAINED, More than
half of material is larger
than No. 200 sieve size.
GROUP SYHBOL TYPICAL NAMES"
GRAVELS CLEAN GRAVELS GW .•.... Well grad~d gravels, g~avel
sand mixtures, little or no
More than half of coarse
fraction is larger than
No. 4 sieve size but
smaller than 3 inches.
SANDS
More than half of
coarse fraction is
smaller than No. 4
sieve size.
fines. . "
GP ..•. ~ . Poorly 'graded gravei s, grave 1-
sand mixtures, 1ittle'or no fine'
- - - - - - ----- -----'~'~ -. ------
GRAVELS WITH
FINES (Appre-
ciable amount
of fines)
GM .•.• ;.Silty gravels', poorly graded
gravel~sand-silt·mixtures.
GC •.•..• Clayey gravels, PQorly graded
gravel-sand-clay mixtures.
CLEAN SANDS SW •..... Well graded sa~d, gravelly sahds, , little or'no fines.
SP ..•... Pborly graded sands, gravelly
, sands, little.or nO fines.
-- - - - -------- - -------~
SANDS WITH
FINES (Appre-
ciable amount
of fines)
SM •••••• Silty sands,. poorly graded
sand-silt mixtures. se .... ~ • Cl ayey s'ands, poorly graded
sand-clay ndxtures.
II. FINE GRAINED, More than
half of material is smaller
than No. 200 sieve size. SILTS AND
CLAYS
r~L •••••• Inorganic 'silts and 'very ftne
s.ands, rock flour, 'sandy silt
or clayey:"silt-sancl-mixtures
with slight plasticity.
Liqu.id Limit CL. .••.. Inorganic clays of low tomedjllm
less than 50 plasticity, gravelly clays,
. sandy clays, silty clays,
lean clays.' .
OL. .... ~Organic silts and organic silty
" € laY,sor.'l ow plasticity. .
-25-
II. Continued
III. HIGHLY ORGANIC SOILS
SILTS AND
CLAYS
. Liqui d Limi t
greater than
50
-26-
MH .•.••. lnorganic silts, micaceous or
di atomaceous fj·ne sandy or
silty soils, elastic silts.
CH •. ~ ... Inorganic clays of high plasticit
fat clays. .
OH •.••.• Organi.c clays of medium to high
plasticity.
PT .•.... Peat and other highly organic
soil s.
MECHANICAL ANALYSIS
Sieve Size
3/8"
#4
#8
#16
#30
#50
#100
#200 .
TEST RESULTS
Tl @ 7.0 1
100.0
99.0
99.7
99.3
97.7
83.3
69.6
55.5
•
Percent Passi,ng
Sample No.
Tl @ 14.0 1
100.0
99.6
99.3
99.0
96.1
79.2
65.6
~8.7
IN-PLACE DENSITY AND MOISTURE CONTENT BY UNDISTURBED SAMPLE
In-Place Density Moisture Content~
Sample (p.c.f.) (Percent of Dry Weight)
Tl @ 5.5 1 97.4 19.8
Tl @ 14.0 1 93.8 18.5
EXPANSION TEST
Expansion*
Sample No. (Percent) Expansion Index
T3 @ @ 2.5 1 17.4 174
* Sample tested from ai'r dry moisture content under a surcharge'
load of 144 psf.
-27-
: •
OPTIMUM MOISTURE AND MAXIMUM DENSITY RELATIONSHIP
Sample No.
T1 @ 14.0'
ANGLE OF INTERNAL FRICTION, 0
Sample No.
T1 @ 5.5
* Assumed from tables.
COHESION, C
Sample No.
Tl @ 5.5
Maximum Density
(p.e.f.)
107.2
Optimum Me-i sture
(Percent)
1.9.2
Angle of Internal Friction, ~*
10°
Cohesion, C (p.s.f.)
250
-28-
• •
APPENDIX C
RECOM~1ENDED GRADING SPECI FICATIONS
GENERAL
I. It shall be the Contractor's responsibility to place, spread, water
and compact the fill in strict ac60rdance with these specifications~ . .
A Soils Engineer shall be the Owner's representative to inspect the
constructiori of fills. Excavation and the placing of fill s~all be
under the direct inspection of the Soils Engineer and he shali give
written notice of conformance with the specifications upon completion
of grad.ing. Deviations from these specifications will be pennitted "
" only upon written authorization from the Soils Engineer. No deviation
from these specifications will be allowed, except where specifically
superceded in the preliminary soils report,'or in other written
communication signed by the Soils Engineer.
SCOPE
II. The placement of fill by the Contractor shall include all clearing
and grubbi.ng, removal of exi sting unsati sfactory' materi a.l, preparation
of the areas to be filled, spreading and compaction of fill in the
areas to be filled, and all other.work necessary to complete the grading
of the filled areas.
MATERIALS
III. A) Materials for compacted fill shall consi~t of any material "that,
in the opinion of the Soils Engineer, is suita~le for use tn construct-
ing fills. No material of a perishable, spongy, or unsuitable nature shall
be used in filling~ .
B) Material placed within 24 inches of rough lot grade shall be select
material that swells less than 3% when compacted as hereinafter specified
for compacted fill and when subjected to an axial ~ressure of 144 psf.
-29-
. . • •
,
C} During grading,operations, soil types other than those
analyzed in the report of the soil investigation may be encount-
ered by the Contractor. The Soil Engineer shall be consulted to
determined the suitability of these. soils.
COMPACTED FILLS
IV. A) GENERAL
L Unless otherwise specified, fill material shall be compacted
by the Contractor whi1e·at a moisture content near the Qptimum
moisture content and to a density that is not less than .90% of
the maximum density determined in accordance with ASTM Test No.
01557-70.
2. Potentially expansive soils may be used in fills ~e10w a, depth
of 24 inches and shall be compacted at a moisture content greater
than the optimum moisture content for the material.
B) CLEARING AND·PREPARING AREAS TO BE FILLED
1. All objectionable material shall be disposed of by, the Contractor.
2. All objectionable material shall be removed by the Contractor from
the surface upon which the fill is to be placed and any loose and
porous soils shall be removed to the depth specified. The surface
shall then be scarified to a minimum depth of 6 inches and recompacted.
3. Where fills are constructed on slopes~ tha Slope of the ~riginal
ground on which the fill is to be placed shall be benched and keyed by
the Contractor as directed by the Soils Engineer. The benches and keys
.sha11 extend completely through the soil mant~e and into the under-
lying formation ·materia1s.
4. After the foundation for the, fill has .been cleared and scarified,
it shall be compacted as specified for fill. ,
C) PLACING, SPREADING, AND COMPACTION OF FILL MATERIAL
1. The fill material shall be placed by the Contractor in layers that
when compacted shall not exceed 6· inches. Each .layer shall be spread
evenly and sh~ll be thoroughly mixed during the spreading to obtain
uniformity of material in each layer.
-30-
• •
I 2. When the moisture content of, the fill material is above t~at
specified py the Soils Engineer, the fi1l material shall be aerated
" by the Contractor by blading, mixing or other satisfactory methods
until the moisture content is as specified.
3. ~Jhen the moisture content of the fill material is below, that
specified by the Soils Engineer, water shall be added by the Con-
tractor until the moisture content is as specified'.
4. After each layer has been placed, mixed and spread even~y, it
shall be thoroughly compacted by the Contractor to the specified
density. Compaction shall be accomplished by suitable ~ompacting
equipment.
GRADING CONTROL'
V. A) Observations and compactiori tests shall be mad~ by the SoilS
Engineer during grading so that he can state that the fill was
constructed in accordance with the spcifications.
B) The Soils Engineer shall make field density tests in accordance
with ASTM Test No. 0-1556-70. When these tests indicate that the
density is below the specified density, that portion shall be re-
worked until the specified density has been obtained.
CONSTRUCTION OBSERVATIONS
VI. A) During construction the contractor shall prop~rly grade all
excavated surfaces to provide positive drainage and prevent ponding
of water. He shall control surface water to avoid damage to ad-
joining properties or to finished work on the'site. The.Contractor
shall take remedial :measures to prevent erosiOn of freshly graded
areas and until such time as permanent drainage and erosion control
measures have been installed.
B) After completion of grading and the Soils Engineer has finished
his observations (j,f the work, no further excavation of filling shall be
do~e except under the observation of the Soils EngiDeer.
-31-
-..