HomeMy WebLinkAboutCT 81-10; Carlsbad Research Center Phase I Lot 9; Compaction Report; 1987-04-01,- SAN DIEGO GEOTECHNICAL CONSULTANTS, INC.
SOIL ENGINEERING 8 ENGINEERING GEOLOGY
- April 1, 1987
- Cardon Meadows Developm 9339 Genessee Avenue, S San Diego, California 92121
No. 05-3205-003-00-10 Log No. 7-1328
- Attention:
SUBJECT:
References:
-
-
-
-
-
-
-
Gentlemen:
Mr. Bob Schmidt
COMPACTION REPORT Proposed Commercial Development Lot 9, Phase I, Carlsbad Research Center Carlsbad, California
San Diego Soils Engineering, Inc., "As-Graded Geotechnical Report, Rough Grading Completed, Carlsbad Research Center, Phase I, Carlsbad, Tract No. 81-10, Carlsbad, California" dated June 7, 1984, Job No. SD1144-10
San Diego Geotechnical Consultants, Inc., "Foundation Investigation, Proposed Commercial Development, Lot 9, Phase I, Carlsbad Research Center, Carlsbad, California," dated July 18, 1986, Job No. 30038-00
Submitted herewith is the report of observation and tests
performed during precise grading at the subject site. Field
density test locations are shown on the Plot Plan, Plate 1, test
results are tabulated on Table I. "Results of Compaction
Tests." The development consists of construction of three
concrete tilt-up buildings with panel heights of approximately 20
to 28 feet, and concrete slab on-grade. The purpose of the
grading and compaction was to grade the building pads to precise
grade.
ENGINEERING DEPT. LIBRARY
City of Carlsbad
2075 Las Palmas Drive
CartsbaQ CA 92009-4859
6455 NANCY RIDGE DRIVE l SUITE 200 l SAN DIEGO, CALIFORNIA 92121 l (619) 587-0250
-
-
-
7
,-
-
-
-
-
-
-
-
-
-
-~
Cardon Meadows Development April 1. 1987 Job No. 05-3205-003-00-10 Log No. 7-1323 Page 2
1.0 PREVIOUS GRADING
.The site had been previously rough-graded during the mass-
grading of the Carlsbad Research Center. The mass-grading
was performed using the observation and testing services of
San Diego Geotechnical Consultants, Inc. (see referenced
As-Graded Geotechnical Report).
2.0 PREPARATION OF EXISTING GROUND
The exposed subgrade soil in areas to receive fill was
scarified 8 to 12-inches, brought to near optimum moisture
conditions and compacted to at least 90 percent relative
compaction.
3.0 SOILS TYPES
The soils encountered during grading consisted of light
gray-brown clayey silt. The soil types used as fill are
tabulated in Table II, "Laboratory Test Results."
4.0 FILL PLACEMENT
Fill soils were placed in 6 to 8 inch lifts, brought to near
optimum moisture content and compacted to a minimum of 90
percent of the maximum density as determined by ASTM
D1557-78 (Five Layer Method). Grading operations were
started and completed during the period covered by this
report, February 23 to March 30, 1987.
Density tests were made in accordance with ASTM D1556-82
(Sand-Cone Method), and ASTM D2922-81 (Nuclear Method).
Results of the density tests made during the recompaction of -
-
-
-
-
-
-
-
-
-
Cardon Meadows Development April 1, 1987 Job No. 05-3205-003-00-10 Log No. 7-1328 Page 3
the fill are tabulated in Table I. Results of the maximum
density and optimum moisture determination of the various
.'soils encountered are tabulated in Table II, "Laboratory
Test Results".
5.0 CONCLUSIONS
Based on the results of the observations and testing noted
herein, it is our opinion that the grading and compaction
was performed in general accordance with our recommendations
and the requirements of the City of Carlsbad. The
condition at the site were found to be consistent with
those indicated in the referenced Foundation Investigation.
Therefore, the recommendations contained in the referenced
report are valid and should be fully complied with.
Utility trench and/or wall backfill consisting of the
on-site material types should be placed by mechanical
compaction to a minimum of 90 percent of the laboratory
maximum density.
All foundation excavations should be observed by the San
Diego Geotechnical Consultants, Inc., prior to placement of
forms or reinforcement to determine that soil bearing
conditions are as anticipated. ALL excavations should be
trimmed neat, level, and square. All loose or sloughed
material should be removed prior to the placement of
concrete. Materials from footing excavations should not be
spread in slab-on-grade areas unless compacted to a minimum
relative compaction of 90 percent.
-
-
-
-
-
-
-
-
-
-
-
-
Cardon Meadows Development April 1, 1987
6.0 LIMITATIONS OF INVESTIGATION
Job No. 05-3205-003-00-10 Log No. 7-1328 Page 4
.Cur description of grading operations, as well as
observations and testing services herein, have been limited
to those grading operations performed between February 23,
and March 30, 1987. No representations are made as to the
quality or extent of materials not observed, or for any
subsequent changes made to this site.
Elevations and test locations noted in the attached Table I
are estimated from field surveys done by others. Based upon
our observations and testing, it is our opinion, as afore-
mentioned, that the work performed has been accomplished in
accordance with our recommendations as well as the require-
ments of the regulating agencies. This report should be
considered subject to review by the controlling authorities.
Professional judgements represented in this report are based
partly on our evaluations of the technical information
gathered, our understanding of the proposed construction,
and our general experience in the geotechnical field. Our
engineering work and judgments rendered meet or exceed the
standard of care of our profession at this time. No other
warranty, expressed or implied, is made as to the
conclusions and professional advice included in this report.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Cardon Meadows Development April 1, 1987 Job No. 05-3205-003-00-10 Log No. 7-1328 Page 5
The opportunity to be of service is appreciated. If you have any
questions, please call.
Very truly yours,
SAN DIEGO GEOTECHNICAL CONSULTANTS, INC.
Robert M. Pintner Staff Engineer
RMP/AFB/pb
Attachments: Plot Plan, Figure 1 Tables I and II
Distribution: (6) Addressee
-
-
-
-.
-
,-
-
-
-
-
-
-
-
-
-
-
-
-
-
..~
-
TABLE I
RESULTS OF COMPACTION TESTS
OS tY& 3205-003-00-10 NAME, Cardon Meads Canwrcial WV.
t9ecs.T DATEZ&&~ 1987
MOISTURE UNIT DRY RELATIVE EST NO. DATE EpEyATT$,N CONT;NT DE&X;Y COMPACTION so’L 6) TYPE
1 3-2-87 289 21.8 97.5 89"" 1 See Test K3
2 3-2-87 289 21.2 93.6 85* 1 See Test /14
3 3-2-87 289 20.5 94.0 a6** 1 See Test %5
4 3-2-87 289 20.6 101.0 92 1 Retest of bl
5 3-2-87 289 19.8 200.7 -92 1 Retest of #2
6 3-2-87 289 22.1 200.2 91 1 Retest of W3
7 3-3-87 291 20.1 102.7 93 1
8 3-3-87 292 20.2 201.3 92 1
9 3-3-87 293 21.4 100.7 92 1
10 3-4-87 290 20.6 102.9 91 2
11 3-4-87 290 20.1 202.8 91 2
12 3-4-87 292 21.4 100.6 92 1
13 3-4-87 292 19.6 102.9 91 2
14 3-4-87 290 21.0 102.0 90 2
15 3-5-87 293 19.5 102.4 90 2
16 3-5-87 290 20.6 101.0 92 1
17 3-5-87 291 19.3 201.2 92 1
18 3-5-87 290 22.1 101.8 90 2
19 3-18-87 292 19.1 96.5 88** 1 See Test #24
20 3-18-87 292 17.5 97.7 89** 1 See Test #25
21 3-18-87 292 21.3 92.3 84** 1 See Test t26
22 3-18-87 295 19.2 95.8 87* 1 See Test #28
23 3-18-87 295 21.7 92.2 84** 1 See Test #29
24 3-30-87 292 18.8 99.4 91 1 Retest of it19
25 3-30-87 292 16.8 105.6 96 1 Retest of 820
26 3-30-87 292 18.7 101.8 93 1 Retest of W21
27 3-30-87 292 16.9 104.6 92 2
28 3-30-87 295 18.4 101.6 93 1 Retest of #22
29 3-30-87 295 17.3 102.8 94 1 Retest of #23
SEE PLAN FOR TEST LOCATIONS
‘SAND-CONE TEST, ALL OTHERS NUCLEAR DENSITY TESTS
*TEST FAILED. SEE RETEST
SAN DIEGO GEOTECHNICAL CONSULTANTS. INC
-
-_
-
-
-
-
-
-
.-
_-
-
-
.-
-
-
-
-
-
TABLE II
LABORATORY TEST RESULTS
05-3205-003-00-10 OS NO.:
Cardon Fadcws Comercial Dev. NAME: Lot 9. base 1 DATE:APril 1987
SOIL MAXIMUM OPTIMUM
TYPE CLASSIFICATION DENSITY MOISTURE 1PCF) (%)
1 Light gray-brcm silty CLAY 109.8 15.1
2 Light gray-bmm clayey SILT 113.4 15.3
A :. SAN DIEGO GEOTECHNICAL CONSULTANTS. IN<