FINAL COMPACTION AND GRADING REPORT FOR RE-GRADED LOTS 111 THROUGH 116 FOR RESIDENTIAL DEVELOPMENT, PORTION OF TRACT 86-5, "TELESCOPE POINT" PROJECT, CARLSBAD, CALIFORNIA
-
-,
CONDUCTED FOR:
WESTANA BUILDERS/DEVELOPERS 4241 JUTLAND DRIVE, 8215 SAN DIEGO, CALIFORNIA 92117
-
.-.
W.O. 407002 APRIL 6, 1984
-
-
~~-
.,--
--
Esl ACFION GEOTECHNICAL gfG5~ ,‘:.u ; ,:;5 ‘y: L, :, ,: L, :, i ,;;.:#T, .,:.,N .,,T~“cj, INC. ‘:
April 6, 1984 W.O. 407002
Westana Builders/Developers 4241 Jutland Drive, #215 San Diego, California 92117
Gentlemen:
Subject: Final Compaction and Grading Report for Re-Graded Lots 111 through 116 for Residential Development, Portion of Tract 86-5, "Telescope Point" Project Carlsbad, California
Forwarded herewith is the Compaction Report on the above referenced
project. The results of the compaction tests are shown on Table I.
Locations of the tests are shown on the accompanying plot plan.
Laboratory Standard: (ASTM:D-1557-70) 4 inch dia. mold; l/30 cu.ft.vol.; 5 layers - 25 blows per layer; 10 lb. hammer dropped 18 inches
Soil Optimum Max. Dry Density
TYPS Classification Moisture % Lbs./Cu. Ft.
I SAND, RED/BROWN 11.0 125.0
The re-grading of the referenced lots was conducted from March 16,
1984 through March 21, 1984. Supervision was provided during this
period.
-
-
-
The existing high expansive soils were removed from the referenced
lots to a depth of three (3') feet, and replaced with a .low
expansive soil.
The fill soils were placed in six (6") inch lifts, moisture conditioned
and compacted in a like manner.
Compaction was obtained by sheepsfoot and scraper. A water truck was
used for moisture control.
-
1630-G Sw!C Sunkist St., Anaheim, CA 92806 (714) 6342092
--
--
-~-
,-
-
-
Westana Builders/Developers Page 2 W.O. 407002
The relative compaction percent was determined by the Sand Cone Method
(ASTM:D-1557-70) and the Nuclear Method (ASTM:D-2922-7). These tests
were taken a minimum of every 500 cubic yards placed and every two
(2') feet in depth of fill placed.
The proposed structures shall be supported by isolated and continuous
spread footings placed a minimum depth of twelve (12") inches below
lowest adjacent finish grade utilizing a recommended safe bearing
value 2600 pounds per square foot and 2100 pounds per square foot,
respectively. This value is for dead plus live load and may be increased
by one-third (l/3) for total including seismic and wind loads where
allowed by code. Increases in bearing capacity for increases in footing
dimensions are tabulated below:
Minimum Minimum Bearing Increase
TYFS (!LiSt?& (iZZ:i) Value Defpth Wig;hft) Maximum
(psf) (ps /ft)(ps
Continuous 12 12 2100 314 109 4100
Isolated 12 12 2600 314 105 4200
Expansion indexes were determined in accordance with Section 29 of the
U.B.C. 1978 edition. Results are as follows:
Soil Expansion
LFYP Potential
(Lots :ll-116) 23 Low
Footings which span from native material to compacted fill shall be
reinforced with a minimum of one (1) #5 bar top and bottom to control
potential differential movement. Reinforcing bars shall extend a
minimum of ten (10') feet on either side of transition line.
Footings placed on or adjacent to slopes shall have a minimum horizontal
distance of five (5') feet from the edge of the footings to the face of
the slope.
Footings should not be poured until authorization to do so has been
obtained from the Building Inspector. Excavations may be made and
forms set before approval of the report at the owner's risk.
Westana Builders/Developers
Page 3
W.O. 407002
I hereby certify that the subject grading was supervised by me and
the work was done in full compliance with the Grading Ordinance of
the City of Carlsbad, and in accordance with best accepted practices
and the applicable chapter of the U.B.C.
REGULATORY COMPLIANCE
All cuts, fills or processing of original ground under the purview of
this report have been completed under the inspection of and with selective
testing by ACTION GEOTECHNICAL CONSULTANTS and found to be in compliance
with the Grading Code of the City of Carlsbad. The completed work has
been reviewed and is considered adequate for the development now planned.
Our findings were made and recommendations prepared in accordance with
generally accepted professional engineering practices, and no further
warranty is implied nor made.
We appreciate this opportunity to be of servicetoyou.
Respectfully submitted:
ACTION GEOTECRNICAL CONSULTANTS
BRUCE A. PACKARD RCE 13801 VICE PRESIDENT - ENGINEERING
TH:ss
TODD HOUSEAL ' STAFF GEOLOGIST
-
I I I I ‘I I \ / i i i
TEST NO. LOCATION
DEPTH OF TESTS
BELOW FINISH
GRADE (FT.)
MOISTURE (PERCENT) DRY UNIT WEIGHT (LBSXU. FT.)
//3 0
A?. 7
M Y
//6.6
//8.6~
//ZO
24.3
I i I I I
SOIL RELATIVE TYPE COMPACTION
DATE OF
TEST
II 50 7-h -l%l/ I
-
:1 T 1 9/ II I
r w 3-ZO-8f/
T 9J 3 -2/-&f
z- 95 3-/9-d
r 9Y ,1
I 53 II
E-RING --
s.Li
TABLE I
w.0. 407OOL