HomeMy WebLinkAboutCT 83-13; FLOWER FIELDS; ASPHALT PLANT & FIELD INSPECTION; 1986-03-31Client City of Carlsbad
1200 Elm Avenue
Carlsbad CA 92008
Job No. 5025
Lab No. . 086-187
—.ate of Report 3/31/86
0 RECi'T'7Tr Testing Engineers-San. Diego
A Division of United States Testing Company, Inc. -
3467 Kurtz St., P.O. Box 80985, San Diego,: Ca. 92138 (619) 22544-'IL 10
2948 Industry Street, Suite B, Oceanside, Ca. 92054 (619) 757d 48F CARLSr
ENGINEERING DEPARTMENT
PHYSICAL PROPERTIES OF. ASPHALTIC CONCRETE
LABORATORY REPORT
Project Asphalt Plant & Field Inspection P.O. 15427 - TrCct 83-13-
Location Avenida de Anita/Flower Felds Sampled By Date 1.___________
Type of Material " Med./AR 8000 . Submitted By TESD Date 3/11/86
Source of Material Truck 1201T, Load #5 Location Sampled Flower Fields
Sieve Ana1vsi. ASTM C136- . Test Standards are ASTh unless otherwise noted
Sieve
Size
% Passing
Accumulative 'Specification
2"
1"
100 100
100 .
3/8" 89.9 :67-85
No. q 71.6 50-65.
8 4R...3 37-50
16 37.2
30 27.7 15-25
50 16.4
ioo 8.2
200 4.7 3-8
* Specification Data/Comments
Test . Result 'Specification TEST STO
Asphalt Content, % 5.7 . 03272
Percent of Total Mix
Wt. Per 100 Aggregate 5.9
2) City of Carlsbad
I .. . . . Testing Engineers--San Diego
Reviewed by:
Kenkth M. Rowe, NorA County Branch Manager