Loading...
HomeMy WebLinkAboutSDP 02-19; LA COSTA CANYON HOMES; LIMITED SITE INVESTIGATION; 2001-06-09• EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC. c;..t>Po2.,-rq RECEIVED June 9, 2001 10925 HARTLEY ROAD, SUITE "I" SANTEE, CALIFORN_IA 92071 (619) 258-7901 Fax 258-7902 Legacy Development, LLC 6965 El Camino Real, Suite 105-451 Carlsbad, California 92009 Subject: Project No. 01-1147Hl(l) Limited~~igation DEC 3 1 2002 CITY OF CARLSBAD PLANNING DEPT. Propos~ 26-Unit _bpartment Complex 4 Vacan~rth Side of La Costa Avenue West of Romeria Street City of Carlsbad, California. Ladies/ Gentlemen: In accordance with your request, we have performed a limited investigation of the soil conditions at the subject site. The investigation was undertaken to provide the soil engineering criteria for site grading and to recommend an appropriate foundation system for the proposed apartment complex. Our investigation found that the proposed building pads are primarily underlain by undocumented fill soils to a maximum depth of approximately 15 feet below existing grade. Mudstone and sandstone of the Santiago Formation were underlying the undocumented fill. The fill soils generally consist of soft to medium stiff sandy clay exhibiting a moderate expansion potential and a moderate compressibility. It is our opinion that the provided the recommendations c;::onstruction. Respectfully submitted, ~c£.L~ ~>\1 Mamadou Saliou Diallo, P.E RCE 54071 proposed herein development is feasible are implemented during LEGACY !vELOP MENT, LLC PROJECT NO. o'8147 HJ (1) INTRODUCTION This is to present the findings and conclusions of a soils investigation for a proposed 26-unit apartment complex to be located on the north side of La Costa Avenue, west of Romeria Street, in the City of Carlsbad, California. The objectives of the investigation were to determine the existing soils conditions and provide recommendations for site development. In order to accomplish these objectives, five (5) exploratory borings were drilled to a maximum depth of 31.0 feet; undisturbed and loose bag samples were obtained, and laboratory tests were performed. SITE DESCRIPTION AND PROPOSED CONSTRUCTION The subject site is located on the north side of La Costa Avenue, west of Romeria Street, in the City of Carlsbad, California. The site was previously graded into 4 relatively level building pads. Prior to the grading operation, the site sloped moderately to the north. Vegetation consists of grass. The proposed development includes the construction of a 26-unit, two-story over garage apartment complex to be founded on caisson footings with a slab- on-grade floor system. FIELD INVESTIGATION Five exploratory borings were drilled with a gas-powered auger to a maximum depth of 31 feet on April 12, 2001 at the approximate locations shown on the attached Plate No. 1, entitled "Location of Exploratory Borings". A continuous log of the soils encountered was recorded at the time of excavation and is shown on Plates No. 2 & 6 entitled "Summary Sheet". The soils were visually and texturally classified according to the filed identification procedures set forth on the attached Plate No. 7 entitled "Uniform Soil Classification Chart. 2 LEGACY.VELOPMENT, LLC PROJECT NO .147Hl (]) SURFACE CONDITIONS The surface soils encountered during the course of our investigation were fill soils consisting of tan sandy clay, moist to wet, loose to medium dense to a maximum depth of fifteen (15) feet. These soils were underlain by mudstone and sandstone of the Santiago Formation (Tsa). EXPANSIVE SOILS An expansion test was performed on representative samples of the fill soils encountered to determine volumetric change characteristics with change in moisture content. An Expansion index of 61 indicates a moderate potential for expansion. GROUNDWATER Groundwater was not encountered during the course of our investigation. Groundwater is anticipated at a depth greater than 100 feet. We do not expect ground water to affect the proposed development. GEOLOGIC HAZARDS A review of the available geological literature pertaining to the site indicates the existence of the Rose Canyon Fault Zone approximately 10.5 Km to the west. Ground shaking from this fault or one of the major active faults in the region is the most likely happening to affect the site. With respect to this hazard, the site is comparable to others in the general area. The proposed accordance with Building Code California using residential structures should be designed in seismic design requirements of the 1997 Uniform or • the Structural Engineers Association of the following seismic design criteria: PARAMETER VALUE UBC REFERENCE Seismic Zone Factor, Z 0.40 Table 16-1 Soil Profile Type So Table 16-J Seismic Coefficient, Ca 0.44 Table 16-Q Seismic Coefficient, Cv 0.64 Table 16-R Near-Source Factor, Na 1.0 Table 16-S Near-Source Factor, Nv 1.0 Table 16-T Seismic Source B Table 16-U 3 .;J> LEGACY.VELOPMENT, LLC PROJECT NO .• 147Hl(l) Based on the absence of shallow ground water, type and consistency of the underlying soils, it is our opinion that the potential for liquefaction is very low. • CONC~USIONS AND RECOMMENDATIONS The following conclusions and recommendations are based upon the analysis of the data and information obtained from our soil investigation. This include-s visual inspection; field investigation; laboratory testing and our general knowledge of the soils native to the site. The site is suitable for the proposed development provided the recommendations set forth are implemented during construction. GRADING AND EARTHWORK Site grading should begin with clearing and grubbing, e.g. the removal of vegetation and deleterious materials. It is our understanding that the four previously graded pads will be graded into two level building pads. Therefore, we recommend that the existing fill soils to a minimum depth of five (5) feet be overexcavated, moisture conditioned 2 to 4 percent over optimum and compacted to a minimum of 90 percent relative density. The compacted fill mat will provide support for the garage slabs, underground utilities, driveway .and parking areas. Prior to the fill placement, the lower building pads should be overexcavated to a minimum depth of 2 feet, and recompacted as recommended above. The actual depth apd extent of removal should be evaluated in the field at the time of excavation by a representative of this firm. Grading should be done in accordance with the attached appendix A. IMPORTED SOILS If imported soils are required to achieve proposed grades, they should be non-expansive, i.e. an expansion index of 20 or less and approved by the soils engineer prior to site delivery. 4 LEGAcAl:vELOPMENT, LLCPROJECTNO. l1147HI(IJ Where moisture sensitive floor coverings are anticipated over the slab, the 10-mil plastic moisture barrier should be underlain by a capiilary break at ,least 4 inches thick, consisting of 3/ 4 inch crushed rock. SLOPE SETBACK Proposed structures and other improvements that are located within 8 feet of the face of existing slope could suffer differential movement as a result of the poor lateral stability of these soils. Therefore, caisson footings for the proposed residential development should be placed at least 8 feet back from the top of these slopes. ALTERNATIVE TO CAISSON FOUNDATIONS GRADING AND EARTHWORK Site grading should begin with clearing and grubbing, e.g. the removal of vegetation and deleterious materials. The undocumented fill and mudstone layer should be overexcavated, moisture conditioned 2 to 4 percent over optimum and compacted to a minimum of 90 percent rel~tive density. The maximum depth of .overexcavation is anticipated to be_ approximately 15. The actual depth and extent of removal should be evaluated in the field at the time of excavation by a representative of this firm. Grading should be done in accordance with the attached appendix A. FOUNDATION AND SLAB a. Continuous footings and/or spread footings are suitable for use and shall extend a minimum of 24 inches for the two story residential family dwellings into the compacted fill soils. Continuous footings should be 15 inches wide and reinforced with four #5 steel bars; two bars placed near the top of the footings and the other two bars placed near the bottom of the footings. b. Concrete floor slabs should be a minimum 4 inches thick. Reinforcement should consist of #3 bars placed at 12 inches on center each way. Slab reinforcement should be placed within the middle third of the slab by supporting the steel on chairs or concrete blocks "dobies''. The slab should be underlain by 2 inches of clean sand over a 10-mil visqueen moisture barrier and another 2 inche$ of clean sand or gravel not exceeding 3/ 4 inch in size with no more than 5 percent passing the #200 sieve. The effect of concrete shrinkage will result in cracks in virtually all concrete slabs. To reduce the extent of shrinkage, the concrete should be 7 LEGACY,VELOPMENT, LLC PROJECT NO. O'J J 47HI (I) slabs. To reduce the extent of shrinkage, the concrete should be placed at a maximum of 4-inch slump. The minimum steel recommended is not intended to prevent shrinkage cracks. SOIL BEARING VALUE (COMPACTED FILL SOILS) An allowable soil bearing value of 1500 pounds per square foot may be used for the design of continuous foundations and spread footings founded a minimum of 12 inches into the compacted fill soils. This value may be increased by 300 psf for each additional foot of depth to a maximum value of 3000 lb/ft2. LATERAL SOIL PRESSURE Lateral resistance to horizontal movement may be provided by the soil passive pressure and the friction of concrete to soil. An allowable passive pressure of 1;30 pounds per square foot per foot of depth may be used. A coefficient of friction of 0. 25 is recommended. The soils passive pressure as well as the bearing value may be increased by 1/3 for wind and seismic loading. SETTLEMENT Settlement of compacted fill soils is normal and should be anticipated. Based on the consolidation test results, a total settlement ·up to 0. 7 5 inches acr.oss the structural span and a corresponding differential settlement up to 0.50 inches need to be considered in the structural design. UTILITY TRENCH EXCAVATIONS Excavations for on-site utility trenches may be made vertically for shallow depths and must be either shored or sloped at lH: lV for depths greater than 4 feet. Utilities should be bedded and backfilled with clean sand or approved granular soil to a depth of at lea-st one foot over the pipe. This backfill shall be uniformly watered and compacted to a firm condition for pipe support. The remainder of the backfill shall be on-site soils or non-expansive imported soils, which shall be placed in thin lifts, moisture-conditioned and compacted to at least 90 % relative compaction. 8 LEGAC~VELOPMENT, LLC PROJECT NO. ~ 147Hl (1) I R s BORINGN0.1 N E 0 M L I p 0 A s L EQUIPMENT: GAS-POWERED AUGER L I T 0 A s I I C C T V D L L SAMPLING METHOD: E u E E A R p s s C= CHUNK SAMPLE D E C T A s B= BULK SAMPLE, R 0 H M I y C M p F U= UNDISTURBED DRIVE 0 p I L I D N A N E C E T C A N E T F T T s N I E y I I T 0 E p 0 SOIL DESCRIPTION T N T E N y % % 0 SC FILL (Qat) -TAN BROWN, MOIST, LOOSE TO MEDIUM DENSE, CLAYEY SAND I ...... -.. -B 100.l 21.5 88 2 - 3 -" " " " WET, MEDIUM DENSE 4 - 5 ............ - 6 - 7 - 8 - 9 - 10 - II SC SANTIAGO FORMATION (Tsa) -BLUEISH GRAY, MOIST TO WET, CLAYEY SAND 12 . 100.3 23.6 88 - 13 ........... CL. BROWN, MOIST, SOFT TO MEDIUM STIFF CLAY 13. 0'-13. S'= 8 BLOWS (SPT) -u 13. S'-14. 0'= 14BLOWS (SPT) 14 . 14. 0'-14. 5'=25 BLOWS (SPT) -14. S'-15. 0'=13 BLOWS (SPT) 15 15. 0'-15. 5'=13 BLOWS (SPT) 105.7 19.6 -SM TAN, MOIST, DENSE, FINE GRAINED SILTY SAND IS. S'-16. 0'=41 BLOWS (SPT) 16 ------103.7 19.3 -17 BOTTOM OF BORING -18 PLATENO.-2 I D~TE LOGGED: APRIL 12, 2001 LOGGED BY: M. DUNCAN LEGAcAl:vELOPMENT, LLCPROJECTNO. l1147HJ(JJ I R s BORJNGNO. 2 N E 0 M L I p 0 A s L EQUIPMENT: GAS-POWERED AUGER L I T 0 A s I I C C T V D L L SAMPLING METHOD: E u E E A R p s s C= CHUNK SAMPLE D E C T A s B= BULK SAMPLE, R 0 H M I y C M p F U= UNDISTURBED DRIVE 0 p I L I D N A N E C E T C A N E T F T T s N I E y I I T 0 E p 0 SOIL DESCRIPTION T N T E N y % % 0 FILL (Qat) -TAN BROWN, MOIST TO WET, LOOSE TO MEDIUM DENSE, CLAYEY SAND 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 SM SANTIAGO FORMATION (Tsa) -........... LIGHT TAN, MOIST, DENSE, FINE GRAINED SILTY SAND 14 -B -.......... 15 -BOTTOM OF BORING 16. - 17 - 18 PLATE NO. 3 I I DATE LOGGED: APRIL 12, 2001 LOGGEDBY:M.DUNCAN 11 LEGACY.VELOPMENT, LLC PROJECT NO .• 147Hl (1) I R s BORING NO. 3 N E 0 M L I p 0 A s L EQUIPMENT: GAS-POWERED AUGER L I T 0 A s I I C C T V D L L SAMPLING METHOD: E u E E A R p s s C= CHUNK SAMPLE D E C T A s B= BULK SAMPLE, R 0 H M I y C M p F U= UNDISTURBED DRIVE 0 p I L I D N A N E C -E T C A N E T F T T s N I E y I I T 0 E p 0 SOIL DESCRIPTION T N T E N y % % I, FILL (Qaf) 0 SC TAN BROWN, MOIST, LOOSE TO MEDIUM DENSE, CLAYEY SAND ---- 5 ----.......... 9. 0'-9. 5'=8BLOWS(SPT) IO -U 9. 5'-IO. 0'= 13 BLOWS (SPT) -.......... IO. 0'-IO. 5'=40BLOWS (SPT) 107.0 20.7 94 --- 15 SANTIAGO FORMATION (Tsa) -CL · DARK GRAYISH BROWN, MOIST, MEDIUM STIFF CLAY --- 20 ---SC-TAN MOIST, MOIST, DENSE, CLAYEY SAND -SM 25 . SM TAN, MOIST, DENSE, FINE GRAINE:D SILTY SAND -BOTTOM -OF BORING . . 30 PLATENO.4 · . I DATE LOGGED: APRIL 12, 2001 LOGGED BY:,M. DUNCAN 12 LEGAC~VELOPMENT, LLCPROJECTNO. l1147Hl(l) I R s BORINGN0.4 N E 0 M L I p 0 A s L EQUIPMENT: GAS-POWERED AUGER L I T 0 A s I I C C T V D L L SAMPLING METHOD: E u E E A R p s s C= CHUNK SAMPLE D E C T A s B= BULK SAMPLE, R 0 H M I y C M p F U= UNDISTURBED DRIVE 0 p I L I D N A N E C E T C A N E T F T T s N I E y I I T 0 E p 0 SOIL DESCRIPTION T N T E N y % % FILL (Qat) 0 SC TAN BROWN, MOIST, LOOSE TO MEDIUM DENSE, CLAYEY SAND --- -5 ---SANTIAG,0 FORMATION (Tsa) -CL DARK GRAYISH BROWN, MOIST, MEDIUM STIFF CLAY 10 --BROWN, MOIST, MEDIUM_STIFF SANDY CLAY -- 15 ---- 20 --SC-TAN MOIST, MOIST, DENSE, CLAYEY SAND -SM - 25 -SM TAN MOIST, DENSE, FINE GRAINE SILTY SAND ---30 BOTTOM OF BORING ----35 PLATE NO. 5 I DATE LOGGED: APRIL 12, 2001 LOGGED BY: M. DUNCAN 13 LEGAc.AlvELOPMENT, LLCPROJECTNO. '1147Hl(l) I R s BORING NO. 5 N E 0 M L I p 0 A s L EQUIPMENT: GAS-POWERED AUGER L I T 0 A s I I C C T V D L L SAMPLING METHOD: E u E E A R p s s C= CHUNK SAMPLE D E C T A s B= BULK SAMPLE, R 0 H M I y C M p F U= UNDISTURBED DRIVE 0 p I L I D N A N E C E T C A N E T F T T s N I E y I I T 0 E p 0 SOIL DESCRlPTION T N T E N y % % 0 SC FILL(Qat) -TAN BROWN, MOIST TO WET, LOOSE TO MEDIUM DENSE, CLAYEY SAND 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 CL SANTIAGO FORMATION (Tsa) -BLUEISH GRAY, MOIST, SOFT ro MEDIUM STIFF CLA y 13 - 14 SM TAN MOIST, DENSE, FINE GRAINED SILTY SAND -15 - 16 - 17 17 0'-17. 5'=28 BLOWS (SPT) -17 5'-18. 0'=70 BLOWS (SPT) 18 BOTTOM OF BORING PLATE NO. 6 I DATE LOGGED: APRIL 12, 2001 LOGGED BY: M. DUNCAN 14 ·• LEGAcYlvELOPMENT, LLC PROJECT NO. ol147HI (JJ LABORATORY T~ST RESULTS PAGE L-1 The maximum dry densities and optimllhl moisture contents of the fill materials as determined by ASTM D1557-91, Procedure A and B which uses 25 blows of a 10 pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 4 inch diameter 1/30 cubic foot compaction cylinder and Procedure C which uses 56 blows of a 10 pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 6 inch diameter 1/13 .3 cubic foot compaction cylinder are presented as follows: SOIL TYPE/PROCEDURE BORING NO. 1 @ 1.0' TO 11.0' 1/A TAN BROWN SILTY CLAYEY SAND MAXIMUM DRY DENSITY LB/CU. FT. 114.0 OPTIMUM MOISTURE CONTENT %DRYWT. 14.8 An expansion test in conformance with UBC 18-2 was performed on representative samples of on- site soils to determine volumetric change characteristics with change in moisture content. The recorded expansion of the sample is presented as follows: INITIAL SATURATED INITIAL DRY MOISTURE MOISTURE DENSITY EXPANSION CONTENT% CONTENT% LB.ICU. FT. INDEX BORING NO. 2@ 1.0' TO 3.5' 13.6 29.7 97.5 61 15 .. , LEGACY D'ELOPMENT, LLC PROJECT NO. 01,47HJ(l) REFERENCES 1: "1997 Edition, Uniform · Building Code, Volume 2, Structural Engineering and Design Provisions". 2. "Maps of Known Active Fault Near-Source Zones in California and Adjacent Portions of. Nevada", Page 0-38, used with the 1997 Edition of the Uniform Building Code, Published by International Conf·erence of Building Officials. 3. "Geologic Maps of th~ Northwestern Part of San Diego County, California. Plate No. 2, Geologic Maps of the Encinitas and Rancho Santa Fe 7.5' Quadrangles", by Siang s. Tan and Michael P. Kennedy, 1996. 4: "Soii Mechanics in Engineering Practice, 3rd Edition", by K. Tetzaghi, R. B. Peck and G. Mesri, Dated 1996 5: "Drilled Piers and Caissons II", New York, NY, American Society of Civil Engineers, 153 p., Baker, C.M., Jr., -Oated 1985. 16 • . ) LEGACY.VELOPMENT, LLC PROJECT NO. ol147HI(IJ LABORATORY TEST RESULTS PAGE L-1 The maximum dry densities and optimum moisture contents of the fill materials as determined by ASTM D1557-91, Procedure A and B which uses 25 blows of a 10 pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 4 inch diameter 1/30 cubic foot compacfam cylinder and Procedure C which uses 56 blows of a 10 pound slide hammer falling from a height of 18 inches on each of 5 equal layers in a 6 inch diameter 1/13.3 cubic foot compaction cylinder are presented as follows: SOIL TYPE/PROCEDURE BORING NO. 1 @ 1.0' TO 11.0' 1/A TAN BROWN SILTY CLAYEY SAND MAXIMUM DRY DENSITY LB/CU. FT. 114.0 OPTIMUM MOISTURE CONTENT %DRY WT. 14.8 An expansion test in conformance with UBC 18-2 was performed on representative samples of on- site soils to determine volumetric change characteristics with change in moisture content. The recorded expansion of the sample is presented as follows: INITIAL SATURATED INITIAL DRY MOISTURE MOISTURE DENSITY EXPANSION CONTENT% CONTENT%. _LB.ICU. FT. INDEX BORING NO. 2@ 1.0' TO 3.5' 13.6 29.7 97.5 61 15 . , • DIRECT SHEAR SUMMARY 5000 4500 4000 3500 Ci:' f 3000 .... Cf) Cf) w ~ 2500 : Cf) v· 0:: ~ 2000 ./ V ,,,,--- Cf) ,/ 1500 V I I l 1000 / 500 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 NORMAL STRESS [PSF] (2 13/32" SAMPLE) I l 2M (0.545) 1L (1.093) 2L (2.185) ANGLE OF COHESION INTERNAL INTERCEPT SAMPLE DESCRIPTION FRICTION (PSF) H3@9'-10 Undisturbed 22 ° 1000 ~ SOUTHERN CALIFORNIA _LEGACY D~VELOPMENT, LLC PROJECT SOIL & TESTING, INC. BY: OBA/SD IDATE: 04-27-01 ~~ JOB NUMBER: Ol-11li.7Hl Ci) I 'pA,~'R T-2 • DIRECT SHEAR SUMMARY 5000 4500 4000 I 3500 -LL. f 3000 -U) U) w 1: 2500 I U) ! a:: i ~ 2000 i i V ti) / 1500 Y ~ 1000 I . V l ~v i ' I I l 500 ' V i I ! i I 0 ; 0 500 1000 1500 -2000 2500 3000 3500 4000 4500 5000 NORMAL STRESS [PSF] (213/32" SAMPLE) 2M (0.545) 1L (1.093) 2L (2.185) ANGLE OF COHESION INTERNAL INTERCEPT SAMPLE DESCRIPTION FRICTION (PSF) H5@ 17' Undisturbed 30 ° 300 ~~· SOUTHERN CALIFORNIA LEGACY DEVELOPMENT, LLC PROJECT \,~~ SOIL & TESTING, INC. BY: OBA/SD !DATE: 04-27-01 - .. JOB NUMBER: 01-U47Hi°(l) I. 'PA(!H' T-~ • EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC. 10925 HARTLEY ROAD, SUITE I SANTEE, CALIFORNIA 92071 (619) 258-7901 APPENDIX A RECOMMENDED EARTHWORK SPECIFICATIONS 1. General Description· The intent of these specifications is to obtain uniformity and adequate strength in filled ground so that the proposed structures may be safely supported. The procedures include the clearing and preparation of the land to be filled, processing the fill soils, the spreading, and compaction of the filled areas to conform with the lines and grades as shown on the approved plans. The owner shall retain a Civil Engineer qualified in soil mechanics (herein referred to as engineer) to inspect and test earthwork in accordance with these specifications. The engineer shall advise the owner and grading contractor immediately if any unsatisfactory conditions are observed to exist and shall have the authority to reject the compacted filled ground until such time that corrective measures are taken, necessary to comply with the specifications. It shall be the sole responsibility of the grading contractor to achieve the specified degree of compaction. 2. Preparing Areas to be 'Filled (a) All brush, vegetation and any biodegradable refuse shall be removed or otherwise disposed of so as to leave the ,areas to be filled free of vegetation and debris. Any uncompacted filled ground or loose compressible natural ground shall be removed unless the report recommends otherwise. Any buried tanks or other structures shall be removed and the depression backfilled to the satisfaction of the engineer. (b) The natural ground which is determined to be satisfactory for the support of the filled ground shall then be plowed or scarified to a depth of at least 12 inches (12"). ( c) After the natural ground has been prepared, it shall then be brought to the proper moisture content and compacted to not less than 90 percent of maximum dry density in accordance with ASTM D1557-9'1. ( d) Where fills are made ort slopes greater than 20 percent, horizontal benches shall be cut into the firm natural ground. The initial bench at the toe of the fill shall be at least 15 feet in width on firm undisturbed natural ground. The width of all succeeding benches shall be at least 6 feet. ~ EAST COUNTY SOIL CONSULTATION AND ENGINEERING, INC. 10925 HARTLEY ROAD, SUITE I SANTEE, CALIFORNIA 92071 (619) 258-7901 APPENDIXC RECOMMENDED PROCEDURES FOR SLAB FOUNDATIONS BASED ON EXPANSION INDEX For soils that are expansive with respect to change in volume with change in moisture content, there is no economical way to absolutely prevent movement if there is a change in moisture content. Therefore, insofar as it is feasible, stable soil moisture content should be established and maintained throughout the life of the structures. Since it is usually not practical to maintain a completely stable soil moisture content, in order to minimize the undesirable effects of the expansive soils ort the structures if these soils are placed or allowed to remain within the upper three feet below finish grade, it is recommended that the following special precautions be exercised in desigri and construction of slabs and foundations. a. Design of foundations and slabs on expansive soils are presented in Table 1 based on expansion indices and there may be more stringent structural design or agency requirements. As an alternative to conventionally reinforced concrete foundations, post-tensioned structural slab systems, designed by a structural engineer, may be utilized. b. Footing depth should be measured below lowest exterior finish grade. c. A reinforced concrete grade beam should be constructed across garage entrances, with similar depth and reinforcement as adjacent perimeter footings for all soils with expansion potential greater than "very low". d. For soil with a potential expansion greater than "low", interior isolated spread footings are not recommended. e. Where pre-saturation is recommended beneath interior slabs, the recommended moisture should penetrate to one foot below the depth of the perimeter footings. Pre-saturation should be completed at least 24 hours prior to concrete placement. f. For soils with an expansive index greater than "low" slab reinforcement should be structurally tied to the footings.