HomeMy WebLinkAboutCT 2017-0006; ROOSEVELT TOWNHOMES; RESULTS OF PERCOLATION TESTING; 2018-12-03ALLIED EARTH TECHNOLOGY 7915 SILVERTON AVENUE, SUITE 317 SAN DIEGO, CALIFORNIA 92126 PH. (858) 586-1665 FAX (858) 586-1650 (619) 447-4747 ROBERT CHAN, P.E. December 3, 2018 2569 Roosevelt LLC 4040 McArthur Boulevard Newport, CA. 92107 Subject: Gentlemen: Project No. 17-1106E5 Results of Percolation Testing Proposed Five Unit Condominium Building Site 2569 Roosevelt Street Carlsbad, California DEC 12 2018 CITV _,, ; i · In accordance with your request, we have performed percolation tests in the subgrade soils beneath the proposed driveway on subject property, located at 2569 Roosevelt Street, in the City of Carlsbad, State of California. Subject property is more specifically referred to as being a portion of Lot No. 22 of Seaside Lands, according to Map thereofNo. 1722 (APN 203-101-35-00). The location of subject property is shown on Figure No. 1, entitled, "Location Map". The purpose of the percolation testing is to determine the permeability of the subgrade soils beneath the porous concrete pavement for water infiltration purposes. Percolation Testing (Simple Open Pit Infiltration Test) In order to accomplish this purpose, two percolation test borings were excavated in the subgrade soils beneath the proposed driveway pm the site. The location of these percolation test borings are shown on Figure No. 2, entitled, "Approximate Location of Percolation Tests". Two percolation test borings approximately 12 inches in diameter were excavated to a depth of 3 feet. The bottom of the boring was cleared and leveled, and covered with 3 inches of gravel. These test borings were presoaked for 4 hours prior to performing the percolation tests. During the testing, a minimum of 6 inches of water was placed in the borings, and the rate of the drop in / ProjectNo. 17-1106E5 2569 Roosevelt LLC 2569 Roosevelt Street 12/03/18 Page2 water level was recorded at approximately 30 minute intervals. This procedure was repeated until rates varied generally less than 10 percent. The stabilized percolation rates are presented below:; Initial Final Change Time Depth Depth in Water Percolation Boring Start Stop Interval to Water to Water Level Rate # Time Time (Min.) (in.) (in.) (in.) (min.Jin.) 1 9:00 9:30 30 38.0 40.0 2.0 15.0 1 9:30 10:00 30 39.5 41.0 1.5 20.0 1 10:00 10:30 30 39.0 40.4 1.4 21.4 1 10:30 11:00 30 39.2 40.6 1.4 21.4 2 11:30 12:00 30 40.0 42.0 2.0 15.0 2 12:00 12:30 30 41.0 42.7 1.7 17.6 2 12:30 13:00 30 42.0 43.2 1.2 25.0 2 13:00 13:30 30 43.0 44.2 1.2 25.0 Description of Property Subject property is a rectangular-shaped lot of 9,642 square feet, situated on the west side of Roosevelt Street, approximately 200 feet south of Laguna Drive. The topography of the general area may be described as relatively level; with surface drainage in a westerly direction. An older residence and detached garage currently occupy the site. All existing structures and improvements will be demolished to accommodate the proposed development. The property is located in a developed area of Carlsbad. The site is bounded on the east by Roosevelt Street; and on the north, west and south by existing commercial buildings. On-Site Soil Conditions A review of geologic maps as well as observations made during our subsurface exploration indicates that the general area is underlain by late to middle Pleistocene Old Paralic Deposits Unit 6-7. On subject property, these Old Paralic Deposits were encountered in the form of medium dense to dense brow/light brown silty fine sands. The Old Paralic Deposits were overlain by a loose residual/topsoil layer on the order of 12 to 18 inches in thickness. Project No. 17-1106E5 Groundwater 2569 Roosevelt LLC 2569 Roosevelt Street 12/03/18 Page 3 No groundwater was encountered in the exploratory trenches during the geotechnical investigation to the maximum depth of exploration at 10 feet; and no groundwater was encountered to a depth of 25 feet at a nearby site, approximately ½ mile to the southwest. Conclusion 1. The vertical distance from the subgrade of the on-site driveway to the seasonal high groundwater mark is greater than 10 feet. 2. The soil through which infiltration is to occur has physical and chemical characteristics which are adequate for proper infiltration durations and treatment of runoff for the protection of groundwater beneficial uses. 3. This is a residential project, and the proposed infiltration BMP' s are appropriate. 4. The infiltration BMPs are located a minimum of 100 feet horizontally from any water supply wells and 25 feet from any septic system or as prescribed by County of San Diego Department of Environmental Health. 5. A factor of safety of 2 should be applied in the sizing of the infiltration BMPs. ROBERT PROJECT NO. 18-1106 05 FIGURE N0.l = -. . ....... - -•--.. ••• C -••-.. , ')(/STING BUILDING LOCATION OF PERCOLATION TESTS PROJECT NO. 18-1106 D5 ROOSEVELT STREET I P#l 1 ®i -1. FIGURE N0.2 HA L T SUR 5£ASJ()£ LA1'it>S AIAP 1722 POR. LOT 22 __J ... 9 \ I ... I I \ LEGEND P# 1.LOCATION OF PERCOLATION ® TESt HOLE -BORING-· · · -