Loading...
HomeMy WebLinkAbout57C0212; Ponto Drive UC; Carlsbad Blvd; 2008-03-27Caltmns? DEPARTMENT OF TRANSPORTATION Structure Maintenance & Investigations Bridge Inspection Report Bridge Number : 57C0212 Facility Carried: CARLSBAD BLVD Location : 0.1MI NORTH OF AVENIDA City : CARLSBAD Inspection Date : 03/27/2007 Inspection Type Routine FC Underwater Special OtherB D D D D STRUCTURE NAME; PONTO DRIVE UC CONSTRUCTION INFORMATION Year Built : 1952 Year Widened: N/A Length (m) : 25.3 Skew (degrees): 0 No. of Joints : 2 No. of Hinges : 0 Structure Description:Three continuous CIP/RC deck slab spans on two open end RC diaphragm abutments and two RC column (3) bents, all supported on RC spread footings. Span Configuration :(S) 7.3 m, 9.8m, 7.3m (N) c/c LOAD CAPACITY AND RATINGS Design Live Load: MS-18 OR HS-20 Inventory Rating: 32.6 metric tons Operating Rating: 55.3 metric tons Permit Rating : ppppp Posting Load : Type 3 N/A Calculation Method: LOAD FACTOR Calculation Method: LOAD FACTOR Type 3S2 N/A Type 3-3 N/A DESCRIPTION ON STRUCTURE Deck X-Section: (W) 0.2 m br, 0.6m cu, 11.4 m, 0.6 m cu, 0.2 m br (E) Total Width: 13.1m Net Width: 11.4m Rail Description: Concrete Baluster Min. Vertical Clearance: Unimpaired DESCRIPTION UNDER STRUCTURE Channel Description: None. CONDITION TEXT CONDITION OF STRUCTURE No. of Lanes: 2 Rail Code : 0000 There is light scaling of the deck at various locations and there are few scattered minor cracks. There are soffit transverse cracks with light efflorescence. There are erosion at both abutment slopes undermining the footing 300mm x 300mm along the footing. Otherwise, the structure is in good condition. MISCELLANEOUS The street under the structure has been closed to traffic. There is now an unimproved dirt roadway. Printed on:Wednesday 05/02/2007 01:53 PM 57C0212/AAAE/10836 ELEMENT INSPECTION RATINGS F#Elem Element Description 101 101 101 101 101 101 101 101 38 205 215 301 321 339 358 359 Concrete Slab - Bare Reinforced Cone Column or Pile Extension Reinforced Cone Abutment Pourable Joint Seal Reinforced Cone Approach Slab w/ or w/o AC Ovly Concrete Railing (aesthetic/masonry) Deck Cracking Soffit of Concrete Deck or Slab Env Total Units Qty 4 4 4 4 4 4 2 2 280 sq.m. 6 ea. 26 m. 14 m. 2 ea. 63 m. 1 ea. 1 ea. Qty in each Condition State St. 1 St. 2 St. 3 St. 4 St. 5 0 6 26 14 2 63 1 0 280 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 WORK RECOMMENDATIONS - NONE Inspected By : M. Zaarour/ G. Zorapapel xfr; Registered Civil Engineer Printed on: Wednesday 05/02/2007 01:53 PM 57C0212/AAAE/10836 STRUCTURE INVENTORY AND APPRAISAL REPORT **************** IDENTIFICATION ** (1) STATE NAME- CALIFORNIA (8) STRUCTURE NUMBER (5) INVENTORY ROUTE (ON /UNDER )- ON (2) HIGHWAY AGENCY DISTRICT (3) COUNTY CODE 073 (4) PLACE (6) FEATURE INTERSECTED- (7) FACILITY CARRIED- 069 57C0212 1500S1010 11 CODE 11194 PONTO DRIVE CARLSBAD BLVD (9) LOCATION- 0.1MI NORTH OF AVENIDA (11) MILEPOINT/KILOMETERPOINT (12) BASE HIGHWAY NETWORK- NOT ON NET (13) LRS INVENTORY ROUTE & SUBROUTE (16) LATITUDE 33 DEG (17) LONGITUDE 117 DEG (98) BORDER BRIDGE STATE CODE % (99) BORDER BRIDGE STRUCTURE NUMBER 0 0 05 MIN 31 SEC 18 MIN 43 SEC SHARE * ******** STRUCTURE TYPE AND MATERIAL ""-"" (43) STRUCTURE TYPE MAIN : MATERIAL- CONCRETE CONT TYPE- SLAB CODE 201 95.0 (44) STRUCTURE TYPE APPRrMATERIAL- TYPE- (45) NUMBER OF SPANS IN MAIN UNIT (46) NUMBER OF APPROACH SPANS (107) DECK STRUCTURE TYPE- CIP CONCRETE (108) WEARING SURFACE / PROTECTIVE SYSTEM: A) TYPE OF WEARING SURFACE- NONE B) TYPE OF MEMBRANE- NONE C) TYPE OF DECK PROTECTION- NONE *************** AGE AND SERVICE **** (27) YEAR BUILT (106) YEAR RECONSTRUCTED (42) TYPE OF SERVICE: ON- HIGHWAY UNDER- OTHER (28) LANES:ON STRUCTURE 02 (29) AVERAGE DAILY TRAFFIC CODE CODE CODE CODE CODE 1952 0000 1 0 UNDER STRUCTURE 00 11000 (30) YEAR OF ADT 1990 (109) TRUCK ADT 1 % (19) BYPASS, DETOUR LENGTH 2 KM *************** GEOMETRIC DATA **************** (48) LENGTH OF MAXIMUM SPAN 9.8 M (49) STRUCTURE LENGTH 25.3 M (50) CURB OR SIDEWALK: LEFT 0.6 M RIGHT 0.6 M (51) BRIDGE ROADWAY WIDTH CURB TO CURB 11.4 M (52) DECK WIDTH OUT TO OUT 13.1 M (32) APPROACH ROADWAY WIDTH (W/SHOULDERS) 11.3 M (33) BRIDGE MEDIAN- NO MEDIAN 0 (34) SKEW 0 DEG (35) STRUCTURE FLARED NO (10) INVENTORY ROUTE MIN VERT CLEAR 99.99 M (47) INVENTORY ROUTE TOTAL HORIZ CLEAR 11.4 M (53) MIN VERT CLEAR OVER BRIDGE RDWY 99.99 M (54) MIN VERT UNDERCLEAR REF- NOT H/RR 0.00 M (55) MIN LAT UNDERCLEAR RT REF- NOT H/RR 0.0 M (56) MIN LAT UNDERCLEAR LT 0.0 M *************** NAVIGATION DATA *************** (38) NAVIGATION CONTROL- NOT APPLICABLE CODE N (111) PIER PROTECTION- • CODE (39) NAVIGATION VERTICAL CLEARANCE 0.0 M (116) VERT-LIFT BRIDGE NAV MIN VERT CLEAR M (40) NAVIGATION HORIZONTAL CLEARANCE 0.0 M 92.0 N/A (112) (104) (26) (100) (101) (102) (103) (105) (110) (20) (21) (22) (37) SUFFICIENCY RATING = STATUS HEALTH INDEX PAINT CONDITION INDEX = ************* CLASSIFICATION ************* NBIS BRIDGE LENGTH- YES HIGHWAY SYSTEM- NOT ON NHS FUNCTIONAL CLASS- OTHER PRIN ART URBAN DEFENSE HIGHWAY- NOT STRAHNET PARALLEL STRUCTURE- NONE EXISTS DIRECTION OF TRAFFIC- 1 WAY TEMPORARY STRUCTURE- FED. LANDS HWY- NOT APPLICABLE DESIGNATED NATIONAL NETWORK - NOT ON NET TOLL- ON FREE ROAD MAINTAIN- CITY OR MUNICIPAL HIGHWAY AGENCY OWNER- CITY OR MUNICIPAL HIGHWAY AGENCY HISTORICAL SIGNIFICANCE- NOT ELIGIBLE **************** CONDITION *** (58) DECK (59) SUPERSTRUCTURE (60) SUBSTRUCTURE (61) CHANNEL & CHANNEL PROTECTION (62) CULVERTS CODE Y 0 14 0 N 1 0 0 3 04 04 5 CODE 5 6 7 N N ********* LOAD RATING AND POSTING ********* CODE (31) DESIGN LOAD- MS-18 OR HS-20 . 5 (63) OPERATING RATING METHOD- LOAD FACTOR 1 (64) OPERATING RATING- 55.3 (65) INVENTORY RATING METHOD- LOAD FACTOR 1 (66) INVENTORY RATING- 32.6 (70) BRIDGE POSTING- EQUAL TO OR ABOVE LEGAL LOADS 5 (41) STRUCTURE OPEN, POSTED OR CLOSED- A DESCRIPTION- OPEN, NO RESTRICTION (67) (68) (69) (71) (72) (36) (113) (75) (76) (94) (95) (96) (97) (114) (115) **************** APPRAISAL **************** CODE STRUCTURAL EVALUATION 5 DECK GEOMETRY g UNDERCLEARANCES, VERTICAL & HORIZONTAL N WATER ADEQUACY N APPROACH ROADWAY ALIGNMENT 8 TRAFFIC SAFETY FEATURES 0000 SCOUR CRITICAL BRIDGES N ********** PROPOSED IMPROVEMENTS J TYPE OF WORK- LENGTH OF STRUCTURE IMPROVEMENT BRIDGE IMPROVEMENT COST ROADWAY IMPROVEMENT COST TOTAL PROJECT COST YEAR OF IMPROVEMENT COST ESTIMATE FUTURE ADT YEAR OF FUTURE ADT CODE 15000 2015 *************** INSPECTIONS ********** (90) INSPECTION DATE 03/07 (91) FREQUENCY (92) CRITICAL FEATURE INSPECTION: (93) A) FRACTURE GRIT DETAIL- NO MO A) B) UNDERWATER INSP- NO MO B) C) OTHER SPECIAL INSP- NO MO C) 24 MO CFI DATE Printed on:Wednesday 05/02/2007 01:53 PM 57C0212/AAAE/10836