HomeMy WebLinkAboutCT 01-17; TAMARACK AVENUE PROPERTY; HYDROLOGY REPORT FOR TAMARACK AVENUE; 2002-09-16HYDROLOGY REPORT
FOR
TAMARACK AVENUE PROPERTY
Prepared for:
Manning Homes
20151 SW Birch Street, Suite 150
Newport Beach, CA 92660
Prepared by:
bhA, Inc.
land planning, civil engineering, surveying
5115 Avenida Encinas, Suite L
Carlsbad, CA 92008-4387
(760) 931-8700
September 16, 2002
W.O. 597-0810-400
.0
HYDROLOGY REPORT
FOR
TAMARACK AVENUE PROPERTY
Prepared for:
Manning Homes
20151 SW Birch Street, Suite 150
Newport Beach, CA 92660
Prepared by:
bhA, Inc.
land planning, civil engineering, surveying
5115 Avenida Encinas, Suite L
Carlsbad, CA 92008-4387
(760) 931-8700
September 16,2002
W.O. 597-0810-400
TABLE OF CONTENTS
Discussion: Purpose and Scope
Project Description
Study Method
Project Design
Conclusions
II. Calculations
A. Existing Hydrology
B. Proposed Hydrology
C. Hydraulic Grade Line Analysis
D. Inlet Size Calculations
III.
IV.
References
Exhibits
Exhibit A: Existing Hydrology Map
Exhibit B: Proposed Hydrology Map
Exhibit C: Proposed Hydrology Map
L DISCUSSION
PURPOSE AND SCOPE:
The purpose of this report is to publish the results of hydrology and hydraulic computer
analysis for the proposed subdivision known as the "Tamarack Property" in the City of
Carlsbad. The scope is to study the existing and proposed hydrology and hydraulics as it
influences existing storm drain facilities in the vicinity during a 100-year frequency storm event.
PROJECT DESCRIPTION:
The property, which is in the City of Carlsbad, is located along on the south side of Tamarack
Avenue between Hibiscus Drive and Liimiar Lane. The 1.54-acre subdivision will consist 5-
single family residential lots.
The Tamarack Property is currently an agricultural farming and fruit/flower stand operation.
There is one house and an out-building on the project. The site currently drains onto to
Tamarack Avenue where the flow is conveyed to an existing type "B" curb inlet near the
northwesterly comer of Tamarack Subdivision. The flow is then conveyed through an existing
storm drain system in Tamarack Avenue. See Exhibit "A" for the existing hydrology.
The proposed drainage system for Tamarack Subdivision will consist of two on-site curb inlets
along Street "A" near the intersection of Tamarack Avenue and a curb inlet on Tamarack
Avenue. Curb inlets will collect street runoff from Tamarack Avenue and building pad runoff
from the Tamarack Property. The proposed storm drain system will be connected to the
existing storm drain system in Tamarack Avenue at node 75.1 as shown on Exhibit "C".
STUDY METHOD:
The method of analysis was based on the Rational Method according to the San Diego County
Hydrology Manual. The Hydrology and Hydraulic Analysis were done on HydroSoft by
Advanced Engineering Software, version 1.5a.
Existing and proposed drainage basin areas were determined from the existing and proposed
grades shown on the Exhibits "C" and 100 scale ortho topographic maps shown on Exhibits
"A" and "B" from the City of Carlsbad. The Rational Method provided the following variable
coefficients:
Soils type: Soil type "D" will be assumed for the drainage basins for conservative hydrology
calculations.
The runoff coefficient for single family land use reflects a composite value of landscaping, roof
and street runoff per County of San Diego Hydrology Manual County.
Initial Time of concentration (in minutes) = Ti = 60x(11.9x(L^ 3)/H) ^ 0.385 > 5 min.
Page 1
Rainfall Intensity = I = 7.44x(P6)x(Tc)0.645
P6 for 100 year storm = 2.6
PROJECTDESIGN:
Sediment will Ukely be reduced upon site development. The rough graded state of existing site
will contribute more sediment yield than the proposed 5-lot single family residential
development. Construction activity will utilize an Erosion Control Plan and Best Management
Practices (BMP's) to prevent sediment leaving the site. Landscaping of the slopes will be
incorporated into the project to reduce erosion. The irrigation system for these landscaped
areas will be monitored to prevent over watering.
There is no increase in flow due to development of Tamarack Property at the existing storm
drain cleanout (node 75.1) in Tamarack Avenue as shown on Exhibit"C". The proposed land
use for Tamarack Property is consistent with the Zoning and General Plan, and the Conditions
of Approval contained in the Planning Commission Resolution No. CT 01-17/CDP 01-48
Both the 100-year hydrauUc grade line (HGL) and the 100-year energy grade Une (EGL) are
plotted on the Storm Drain Improvement Plans for the Tamarack Property. The EGL
represents the total amount of energy available at any point along a water course, pipe or
drainage structure. Where the water is motionless, the water surface (HGL) would coincide
with the point or the energy grade Une. As the flow of water is accelerated, the HGL drops
further away from the EGL. If the flow is stopped at any point the HGL jumps back to the
EGL. The drop structure is the only point in a storm drain system where the flow velocity is
close to zero. Therefore, the 100-year HGL will represent the water surface elevation at that
point.
CONCLUSION:
The existing flow for a 100-year storm event at node 70.1 is 11.2 cubic feet per second (cfs) as
shown on Exhibit "A." The flow at node 75.1 is 10.6 cfs as shown on Exhibit "C". The existing
and proposed storm drains for the Tamarack Property adequately conveys a lOO-year
frequency storm event. There is no increase in flow due to development of the Tamarack
Property at the existing storm drain cleanout (node 75.1) in Tamarack Avenue.
Page 2
II. CALCULATIONS
A. EXISTING HYDROLOGY
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-98 Advanced Engineering Software (aes)
Ver. l.SA Release Date: 01/01/98 License ID 1459
Analysis prepared by:
BHA INC.
5115 AVENDIA ENCINAS, SUITE L
CARLSBAD, CA 92008
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
************************** DESCRIPTION OF STUDY **************************
* TENTATIVE SUBDIVISION MAP *
* EXISTING 100 YEAR STORM EVENT *
* *
**************************************************************************
FILE NAME: 810-S2.DAT
TIME/DATE OF STUDY: 10:33 9/14/2002
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
1985 SAN DIEGO MANUAL CRITERIA USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) = 2.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = .90
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED
NOTE: ONLY PEAK CONFLUENCE VALUES CONSIDERED
****************************************************************************
FLOW PROCESS FROM NODE 10.00 TO NODE 20.00 IS CODE = 21
»>»RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
*USER SPECIFIED(SUBAREA):
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .9500
INITIAL SUBAREA FLOW-LENGTH = 160.00
UPSTREAM ELEVATION = 60.70
DOWNSTREAM ELEVATION = 58.00
ELEVATION DIFFERENCE = 2.70
URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 2.869
TIME OF CONCENTRATION ASSUMED AS 6-MINUTES
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.090
SUBAREA RUNOFF(CFS) = .58
TOTAL AREAIACRES) = .10 TOTAL RUNOFF(CFS) = .58
****************************************************************************
FLOW PROCESS FROM NODE 20.00 TO NODE 70.00 IS CODE = 6
>»»COMPUTE STREETFLOW TRAVELTIME THRU SUBAREA««<
UPSTREAM ELEVATION = 58.00 DOWNSTREAM ELEVATION = 48.85
STREET LENGTH(FEET) = 360.00 CURB HEIGHT(INCHES) = 6.
STREET HALFWIDTH(FEET) = 32.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK = 30.50
INTERIOR STREET CROSSFALL(DECIMAL) = .020
OUTSIDE STREET CROSSFALL(DECIMAL) = .083
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF = 1
**TRAVELTIME COMPUTED USING MEAN FLOW(CFS) = 3.42
STREETFLOW MODEL RESULTS:
STREET FLOWDEPTH(FEET) = .32
HALFSTREET FLOODWIDTH(FEET) = 9.60
AVERAGE FLOW VELOCITY(FEET/SEC.) = 3.29
PRODUCT OF DEPTH&VELOCITY = 1.05
STREETFLOW TRAVELTIME(MIN) = 1.83 TC(MIN) = 7.83
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.132
*USER SPECIFIED(SUBAREA):
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .4500
SUBAREA AREA(ACRES) = 2.40 SUBAREA RUNOFF(CFS) = 5.54
SUMMED AREA(ACRES) = 2.50 TOTAL RUNOFF(CFS) = 6.12
END OF SUBAREA STREETFLOW HYDRAULICS:
DEPTH(FEET) = .36 HALFSTREET FLOODWIDTH(FEET) = 11.51
FLOW VELOCITY(FEET/SEC.) = 4.24 DEPTH*VELOCITY = 1.51
****************************************************************************
FLOW PROCESS FROM NODE 70.00 TO NODE 70.00 IS CODE = 1
»»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
TOTAL NUMBER OF STREAMS = 2
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE:
TIME OF CONCENTRATION(MIN.) = 7.83
RAINFALL INTENSITY(INCH/HR) = 5.13
TOTAL STREAM AREA(ACRES) = 2.50
PEAK FLOW RATE(CFS) AT CONFLUENCE = 6.12
****************************************************************************
FLOW PROCESS FROM NODE 50.00 TO NODE 60.00 IS CODE = 21
»>»RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
*USER SPECIFIED(SUBAREA):
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .9500
INITIAL SUBAREA FLOW-LENGTH = 150.00
UPSTREAM ELEVATION = 52.00
DOWNSTREAM ELEVATION = 50.00
ELEVATION DIFFERENCE = 2.00
URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 3.004
TIME OF CONCENTRATION ASSUMED AS 6-MINUTES
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.090
SUBAREA RUNOFF(CFS) = .58
TOTAL AREA(ACRES) = .10 TOTAL RUNOFF(CFS) = .58
****************************************************************************
FLOW PROCESS FROM NODE 60.00 TO NODE 70.00 IS CODE = 6
»»>COMPUTE STREETFLOW TRAVELTIME THRU SUBAREA««<
UPSTREAM ELEVATION = 50.00 DOWNSTREAM ELEVATION = 48.85
STREET LENGTH(FEET) = 80.00 CURB HEIGHT(INCHES) = 6.
STREET HALFWIDTH(FEET) = 32.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK = 30.50
INTERIOR STREET CROSSFALL(DECIMAL) = .020
OUTSIDE STREET CROSSFALL(DECIMAL) = .083
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF = 1
**TRAVELTIME COMPUTED USING MEAN FLOW(CFS) = 1.10
STREETFLOW MODEL RESULTS:
STREET FLOWDEPTH(FEET) = .24
HALFSTREET FLOODWIDTH(FEET) = 5.79
AVERAGE FLOW VELOCITY(FEET/SEC.) = 2.42
PRODUCT OF DEPTH&VELOCITY = .59
STREETFLOW TRAVELTIME(MIN) = .55 TC(MIN) = 6.55
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.755
*USER SPECIFIED(SUBAREA):
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .4500
SUBAREA AREA(ACRES) = .40 SUBAREA RUNOFF(CFS) = 1.04
SUMMED AREA(ACRES) = .50 TOTAL RUNOFF(CFS) = 1.61
END OF SUBAREA STREETFLOW HYDRAULICS:
DEPTH(FEET) = .28 HALFSTREET FLOODWIDTH(FEET) = 7.70
FLOW VELOCITY(FEET/SEC.) = 2.27 DEPTH*VELOCITY = .64
****************************************************************************
FLOW PROCESS FROM NODE 70.00 TO NODE 70.00 IS CODE = 1
>»»DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
»»>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES««<
TOTAL NUMBER OF STREAMS = 2
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE:
TIME OF CONCENTRATION(MIN.) = 6.55
RAINFALL INTENSITY(INCH/HR) = 5.75
TOTAL STREAM AREA(ACRES) = .50
PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.61
** CONFLUENCE DATA **
STREAM RUNOFF Tc INTENSITY AREA
NUMBER (CFS) (MIN.) (INCH/HOUR) (ACRE)
1 6.12 7.83 5.132 2.50
2 1.61 6.55 5.755 .50
RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO
CONFLUENCE FORMULA USED FOR 2 STREAMS.
** PEAK FLOW RATE TABLE **
STREAM RUNOFF Tc INTENSITY
NUMBER (CFS) (MIN.) (INCH/HOUR)
1 7.07 6.55 5.755
2 7.56 7.83 5.132
COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS:
PEAK FLOW RATE(CFS) = 7.56 Tc{MIN.) = 7.83
TOTAL AREA(ACRES) = 3.00
****************************************************************************
FLOW PROCESS FROM NODE 70.00 TO NODE 70.10 IS CODE = 4
»»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
>»»USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 18.0 INCH PIPE IS 6.1 INCHES
PIPEFLOW VELOCITY(FEET/SEC.) = 14.4
UPSTREAM NODE ELEVATION = 43.68
DOWNSTREAM NODE ELEVATION = 41.66
FLOWLENGTH(FEET) = 21.06 MANNING'S N = .013
GIVEN PIPE DIAMETER(INCH) = 18.00 NUMBER OF PIPES = 1
PIPEFLOW THRU SUBAREA(CFS) = 7.56
TRAVEL TIME(MIN.) = .02 TC(MIN.) = 7.85
****************************************************************************
FLOW PROCESS FROM NODE 70.10 TO NODE 70.10 IS CODE = 1
»»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
TOTAL NUMBER OF STREAMS = 3
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE:
TIME OF CONCENTRATION(MIN.) = 7.85
RAINFALL INTENSITY(INCH/HR) = 5.12
TOTAL STREAM AREA(ACRES) = 3.00
PEAK FLOW RATE(CFS) AT CONFLUENCE = 7.56
****************************************************************************
FLOW PROCESS FROM NODE 30.00 TO NODE 35.00 IS CODE = 21
»»>RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
INITIAL SUBAREA FLOW-LENGTH = 220.00
UPSTREAM ELEVATION = 53.50
DOWNSTREAM ELEVATION = 51.60
ELEVATION DIFFERENCE = 1.90
URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 15.419
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.313
SUBAREA RUNOFF(CFS) = .55
TOTAL AREA(ACRES) = .30 TOTAL RUNOFF(CFS) = .55
****************************************************************************
FLOW PROCESS FROM NODE 35.00 TO NODE 40.00 IS CODE = 51
»»>COMPUTE TRAPEZOIDAL CHANNEL FLOW««<
»»>TRAVELTIME THRU SUBAREA««<
UPSTREAM NODE ELEVATION = 51.60
DOWNSTREAM NODE ELEVATION = 4 9.50
CHANNEL LENGTH THRU SUBAREA(FEET) = 270.00
CHANNEL SLOPE = .0078
CHANNEL BASE(FEET) = .00 "Z" FACTOR = 1.250
MANNING'S FACTOR = .015 MAXIMUM DEPTH(FEET) = 2.00
CHANNEL FLOW THRU SUBAREA(CFS) = .55
FLOW VELOCITY(FEET/SEC) = 2.61 FLOW DEPTH(FEET) = .41
TRAVEL TIME(MIN.) = 1.72 TC(MIN.) = 17.14
****************************************************************************
FLOW PROCESS FROM NODE 35.00 TO NODE 40.00 IS CODE = 8
»»>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW««<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.094
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
SUBAREA AREA(ACRES) = .80 SUBAREA RUNOFF(CFS) = 1.36
TOTAL AREA(ACRES) = 1.10 TOTAL RUNOFF(CFS) = 1.91
TC(MIN) = 17.14
****************************************************************************
FLOW PROCESS FROM NODE 40.00 TO NODE 40.10 IS CODE = 4
»>»COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
»»>USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 18.0 INCH PIPE IS 4.3 INCHES
PIPEFLOW VELOCITY(FEET/SEC.) = 6.0
UPSTREAM NODE ELEVATION = 44.36
DOWNSTREAM NODE ELEVATION = 43.66
FLOWLENGTH(FEET) = 28.69 MANNING'S N = .013
GIVEN PIPE DIAMETER(INCH) = 18.00 NUMBER OF PIPES = 1
PIPEFLOW THRU SUBAREA(CFS) = 1.91
TRAVEL TIME(MIN.) = .08 TC(MIN.) = 17.22
****************************************************************************
FLOW PROCESS FROM NODE 40.10 TO NODE 70.10 IS CODE = 4
»»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
>»»USING USER-SPECIFIED PIPESIZE<««
DEPTH OF FLOW IN 18.0 INCH PIPE IS 5.3 INCHES
PIPEFLOW VELOCITY(FEET/SEC.) = 4.3
UPSTREAM NODE ELEVATION = 43.46
DOWNSTREAM NODE ELEVATION = 41.66
FLOWLENGTH(FEET) = 179.79 MANNING'S N = .013
GIVEN PIPE DIAMETER(INCH) = 18.00 NUMBER OF PIPES =
PIPEFLOW THRU SUBAREA(CFS) = 1.91
TRAVEL TIME(MIN.) = .69 TC(MIN.) = 17.91
****************************************************************************
FLOW PROCESS FROM NODE 70.10 TO NODE 70.10 IS CODE = 1
>»»DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
TOTAL NUMBER OF STREAMS = 3
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE:
TIME OF CONCENTRATION(MIN.) = 17.91
RAINFALL INTENSITY(INCH/HR) = 3.01
TOTAL STREAM AREA(ACRES) = 1.10
PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.91
****************************************************************************
FLOW PROCESS FROM NODE 68.00 TO NODE 69.00 IS CODE = 21
»>»RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
INITIAL SUBAREA FLOW-LENGTH = 800.00
UPSTREAM ELEVATION =61.80
DOWNSTREAM ELEVATION = 48.66
ELEVATION DIFFERENCE = 13.14
URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 23.733
*CAUTION: SUBAREA FLOWLENGTH EXCEEDS COUNTY
NOMOGRAPH DEFINITION. EXTRAPOLATION OF NOMOGRAPH USED.
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 2.509
SUBAREA RUNOFF(CFS) = 5.11
TOTAL AREA(ACRES) = 3.70 TOTAL RUNOFF(CFS) = 5.11
****************************************************************************
FLOW PROCESS FROM NODE 69.00 TO NODE 70.10 IS CODE = 4
»»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
»>»USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 18.0 INCH PIPE IS 6.3 INCHES
PIPEFLOW VELOCITY(FEET/SEC.) = 9.2
UPSTREAM NODE ELEVATION = 42.66
DOWNSTREAM NODE ELEVATION = 41.66
FLOWLENGTH(FEET) = 27.00 MANNING'S N = .013
GIVEN PIPE DIAMETER(INCH) = 18.00 NUMBER OF PIPES = 1
PIPEFLOW THRU SUBAREA(CFS) = 5.11
TRAVEL TIME(MIN.) = .05 TC(MIN.) = 23.78
****************************************************************************
FLOW PROCESS FROM NODE 70.10 TO NODE 70.10 IS CODE =
»»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
»»>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES««<
TOTAL NUMBER OF STREAMS = 3
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM
TIME OF CONCENTRATION(MIN.) = 23.78
RAINFALL INTENSITY(INCH/HR) = 2.51
TOTAL STREAM AREA(ACRES) = 3.70
PEAK FLOW RATE(CFS) AT CONFLUENCE = 5.11
3 ARE:
** CONFLUENCE DATA **
STREAM
NUMBER
1
2
3
RUNOFF
(CFS)
7.56
1.91
5.11
Tc
(MIN.1
7.85
17.91
23.78
INTENSITY
(INCH/HOUR)
5.121
3.008
2.505
AREA
(ACRE)
3.00
1.10
3.70
RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO
CONFLUENCE FORMULA USED FOR 3 STREAMS.
** PEAK FLOW RATE TABLE **
STREAM
NUMBER
1
2
3
RUNOFF
(CFS)
11.18
10.60
10.39
Tc
(MIN.)
7.85
17. 91
23.78
INTENSITY
(INCH/HOUR)
5.121
3.008
2.505
COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS;
PEAK FLOW RATE(CFS) = 11.18 Tc(MIN.) =
TOTAL AREA(ACRES) = 7.80
7.85
****************************************************************************
FLOW PROCESS FROM NODE 70. 10 TO NODE 70.20 IS CODE
»»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
>»»USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 24.0 INCH PIPE IS 11.4 INCHES
PIPEFLOW VELOCITY(FEET/SEC.) = 7.6
UPSTREAM NODE ELEVATION = 41.46
DOWNSTREAM NODE ELEVATION =
FLOWLENGTH(FEET) = 221.88
GIVEN PIPE DIAMETER(INCH) =
PIPEFLOW THRU SUBAREA(CFS) =
TRAVEL TIME(MIN.) = .48
38.55
MANNING'S N = .013
24.00 NUMBER OF PIPES
11.18
TC(MIN.) = 8.33
END OF STUDY SUMMARY:
PEAK FLOW RATE(CFS) = 11.IE
TOTAL AREA(ACRES) = 7.80
Tc(MIN.) = 8.33
END OF RATIONAL METHOD ANALYSIS
II. CALCULATIONS
B. PROPOSED HYDROLOGY
****************************************************************************
RATIONAL METHOD HYDROLOGY COMPUTER PROGRAM PACKAGE
Reference: SAN DIEGO COUNTY FLOOD CONTROL DISTRICT
1985,1981 HYDROLOGY MANUAL
(c) Copyright 1982-98 Advanced Engineering Software (aes)
Ver. 1.5A Release Date: 01/01/98 License ID 1459
Analysis prepared by:
BHA INC.
5115 AVENDIA ENCINAS, SUITE L
CARLSBAD, CA 92008
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
************************** DESCRIPTION OF STUDY **************************
* TENTATIVE SUBDIVISION MAP *
* PROPOSED 100 YEAR STORM EVENT *
* *
**************************************************************************
FILE NAME: 810-Sl.DAT
TIME/DATE OF STUDY: 7:35 9/16/2002
USER SPECIFIED HYDROLOGY AND HYDRAULIC MODEL INFORMATION:
1985 SAN DIEGO MANUAL CRITERIA
USER SPECIFIED STORM EVENT(YEAR) = 100.00
6-HOUR DURATION PRECIPITATION (INCHES) =2.600
SPECIFIED MINIMUM PIPE SIZE(INCH) = 18.00
SPECIFIED PERCENT OF GRADIENTS(DECIMAL) TO USE FOR FRICTION SLOPE = .90
SAN DIEGO HYDROLOGY MANUAL "C"-VALUES USED
NOTE: ONLY PEAK CONFLUENCE VALUES CONSIDERED
****************************************************************************
FLOW PROCESS FROM NODE 10.00 TO NODE 20.00 IS CODE = 21
»»>RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
*USER SPECIFIED(SUBAREA):
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .9500
INITIAL SUBAREA FLOW-LENGTH = 160.00
UPSTREAM ELEVATION = 60.70
DOWNSTREAM ELEVATION = 58.00
ELEVATION DIFFERENCE = 2.70
URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 2.869
TIME OF CONCENTRATION ASSUMED AS 6-MINUTES
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.090
SUBAREA RUNOFF(CFS) = .58
TOTAL AREA(ACRES) = .10 TOTAL RUNOFF(CFS) = .58
****************************************************************************
FLOW PROCESS FROM NODE 20.00 TO NODE 41.00 IS CODE = 6
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
»»>COMPUTE STREETFLOW TRAVELTIME THRU SUBAREA««<
UPSTREAM ELEVATION = 58.00 DOWNSTREAM ELEVATION = 4 9.50
STREET LENGTH(FEET) = 370.00 CURB HEIGHT(INCHES) = 6.
STREET HALFWIDTH(FEET) = 32.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK = 30.50
INTERIOR STREET CROSSFALL(DECIMAL) = .020
OUTSIDE STREET CROSSFALL(DECIMAL) = .083
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF = 1
**TRAVELTIME COMPUTED USING MEAN FLOW(CFS) = 1.64
STREETFLOW MODEL RESULTS:
STREET FLOWDEPTH(FEET) = .26
HALFSTREET FLOODWIDTH(FEET) = 6.74
AVERAGE FLOW VELOCITY(FEET/SEC.) = 2.87
PRODUCT OF DEPTH&VELOCITY = .75
STREETFLOW TRAVELTIME(MIN) = 2.15 TC{MIN) = 8.15
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.999
*USER SPECIFIED(SUBAREA):
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5200
SUBAREA AREA(ACRES) = .80 SUBAREA RUNOFF(CFS) = 2.08
SUMMED AREA(ACRES) = .90 TOTAL RUNOFF(CFS) = 2.66
END OF SUBAREA STREETFLOW HYDRAULICS:
DEPTH(FEET) = .30 HALFSTREET FLOODWIDTH(FEET) = 8.65
FLOW VELOCITY(FEET/SEC.) = 3.07 DEPTH*VELOCITY = .92
****************************************************************************
FLOW PROCESS FROM NODE 41.00 TO NODE 41.10 IS CODE = 4
»»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
»»>USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 18.0 INCH PIPE IS 4.6 INCHES
PIPEFLOW VELOCITY(FEET/SEC.) = 7.4
UPSTREAM NODE ELEVATION = 4 3.01
DOWNSTREAM NODE ELEVATION = 42.69
FLOWLENGTH(FEET) = 15.76 MANNING'S N = .010
GIVEN PIPE DIAMETER(INCH) = 18.00 NUMBER OF PIPES = 1
PIPEFLOW THRU SUBAREA(CFS) = 2.66
TRAVEL TIME(MIN.) = .04 TC(MIN.) = 8.18
****************************************************************************
FLOW PROCESS FROM NODE 41.10 TO NODE 41.10 IS CODE = 1
»»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
TOTAL NUMBER OF STREAMS = 2
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE:
TIME OF CONCENTRATION(MIN.) = 8.18
RAINFALL INTENSITY(INCH/HR) = 4.99
TOTAL STREAM AREA(ACRES) = .90
I
I
I
I
I
I
I
I
I
I
I
I
I
PEAK FLOW RATE(CFS) AT CONFLUENCE = 2.66
****************************************************************************
FLOW PROCESS FROM.NODE 30.00 TO NODE 35.00 IS CODE = 21
»»>RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
INITIAL SUBAREA FLOW-LENGTH = 220.00
UPSTREAM ELEVATION = 53.50
DOWNSTREAM ELEVATION = 51.60
ELEVATION DIFFERENCE = 1.90
URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 15.419
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.313
SUBAREA RUNOFF(CFS) = .55
TOTAL AREA(ACRES) = .30 TOTAL RUNOFF(CFS) = .55
****************************************************************************
FLOW PROCESS FROM NODE 35.00 TO NODE 40.00 IS CODE = 51
»»>COMPUTE TRAPEZOIDAL CHANNEL FLOW««<
»»>TRAVELTIME THRU SUBAREA««<
UPSTREAM NODE ELEVATION = 51.60
DOWNSTREAM NODE ELEVATION = 4 9.50
CHANNEL LENGTH THRU SUBAREA(FEET) = 270.00
CHANNEL SLOPE = .0078
CHANNEL BASE(FEET) = .00 "Z" FACTOR = 1.250
MANNING'S FACTOR = .015 MAXIMUM DEPTH(FEET) = 2.00
CHANNEL FLOW THRU SUBAREA(CFS) = .55
FLOW VELOCITY(FEET/SEC) = 2.61 FLOW DEPTH(FEET) = .41
TRAVEL TIME(MIN.) = 1.72 TC(MIN.) = 17.14
****************************************************************************
FLOW PROCESS FROM NODE 35.00 TO NODE 40.00 IS CODE = 8
»»>ADDITION OF SUBAREA TO MAINLINE PEAK FLOW««<
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.094
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
SUBAREA AREA(ACRES) = .80 SUBAREA RUNOFF(CFS) = 1.36
TOTAL AREA(ACRES) = 1.10 TOTAL RUNOFF(CFS) = 1.91
TC(MIN) = 17.14
****************************************************************************
FLOW PROCESS FROM NODE 40.00 TO NODE 40.10 IS CODE = 4
»»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
»>»USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 18.0 INCH PIPE IS 4.3 INCHES
I
I PIPEFLOW VELOCITY(FEET/SEC.) = 6.0
UPSTREAM NODE ELEVATION = 44.36
DOWNSTREAM NODE ELEVATION = 43.66
FLOWLENGTH(FEET) = 28.69 MANNING'S N = .013
GIVEN PIPE DIAMETER(INCH) = 18.00 NUMBER OF PIPES =
PIPEFLOW THRU SUBAREA(CFS) = 1.91
TRAVEL TIME(MIN.) = .08 TC(MIN.) = 17.22
****************************************************************************
FLOW PROCESS FROM NODE 40.10 TO NODE 41.10 IS CODE = 4
»»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
»»>USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 18.0 INCH PIPE IS 5.3 INCHES
PIPEFLOW VELOCITY(FEET/SEC.) = 4.3
UPSTREAM NODE ELEVATION = 43.46
DOWNSTREAM NODE ELEVATION = 42.69
FLOWLENGTH(FEET) = 77.45 MANNING'S N = .013
GIVEN PIPE DIAMETER(INCH) = 18.00 NUMBER OF PIPES = 1
PIPEFLOW THRU SUBAREA(CFS) = 1.91
TRAVEL TIME(MIN.) = .30 TC(MIN.) = 17.52
****************************************************************************
FLOW PROCESS FROM NODE 41.10 TO NODE 41.10 IS CODE = 1
»»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
>»»AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES««<
TOTAL NUMBER OF STREAMS = 2
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE:
TIME OF CONCENTRATION(MIN.) = 17.52
RAINFALL INTENSITY(INCH/HR) = 3.05
TOTAL STREAM AREA(ACRES) = 1.10
PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.91
** CONFLUENCE DATA **
STREAM RUNOFF Tc INTENSITY AREA
NUMBER (CFS) (MIN.) (INCH/HOUR) (ACRE)
1 2.66 8.18 4.985 .90
2 1.91 17.52 3.051 1.10
RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO
CONFLUENCE FORMULA USED FOR 2 STREAMS.
** PEAK FLOW RATE TABLE **
STREAM RUNOFF Tc INTENSITY
NUMBER (CFS) (MIN.) (INCH/HOUR)
1 3.83 8.18 4.985
2 3.54 17.52 3.051
COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS:
PEAK FLOW RATE{CFS) = 3.83 Tc{MIN.) = 8.18
TOTAL AREA(ACRES) = 2.00
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
****************************************************************************
FLOW PROCESS FROM NODE 41.10 TO NODE 75.10 IS CODE = 4
>»»COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
>»»USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 18.0 INCH PIPE IS 7.8 INCHES
PIPEFLOW VELOCITY(FEET/SEC.) = 5.2
UPSTREAM NODE ELEVATION = 42.65
DOWNSTREAM NODE ELEVATION =41.66
FLOWLENGTH(FEET) = 102.34 MANNING'S N = .013
GIVEN PIPE DIAMETER(INCH) = 18.00 NUMBER OF PIPES = 1
PIPEFLOW THRU SUBAREA(CFS) = 3.83
TRAVEL TIME(MIN.) = .33 TC(MIN.) = 8.51
****************************************************************************
FLOW PROCESS FROM NODE 75.10 TO NODE 75.10 IS CODE = 1
»»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
TOTAL NUMBER OF STREAMS = 2
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE:
TIME OF CONCENTRATION(MIN.) = 8.51
RAINFALL INTENSITY(INCH/HR) = 4.8 6
TOTAL STREAM AREA(ACRES) = 2.00
PEAK FLOW RATE(CFS) AT CONFLUENCE = 3.83
****************************************************************************
FLOW PROCESS FROM NODE 73.00 TO NODE 74.00 IS CODE = 21
»»>RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
INITIAL SUBAREA FLOW-LENGTH = 800.00
UPSTREAM ELEVATION = 61.80
DOWNSTREAM ELEVATION = 48.66
ELEVATION DIFFERENCE = 13.14
URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 23.733
*CAUTION: SUBAREA FLOWLENGTH EXCEEDS COUNTY
NOMOGRAPH DEFINITION. EXTRAPOLATION OF NOMOGRAPH USED.
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 2.509
SUBAREA RUNOFF(CFS) = 5.11
TOTAL AREA(ACRES) = 3.70 TOTAL RUNOFF(CFS) = 5.11
****************************************************************************
FLOW PROCESS FROM NODE 74.00 TO NODE 75.10 IS CODE = 4
»»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
»»>USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 18.0 INCH PIPE IS 6.3 INCHES
PIPEFLOW VELOCITY(FEET/SEC.) = 9.2
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
UPSTREAM NODE ELEVATION = 42.66
DOWNSTREAM NODE ELEVATION = 41.66
FLOWLENGTH(FEET) = 27.00 MANNING'S N = .013
GIVEN PIPE DIAMETER(INCH) = 18.00 NUMBER OF PIPES = 1
PIPEFLOW THRU SUBAREA(CFS) = 5.11
TRAVEL TIME(MIN.) = .05 TC(MIN.) = 23.78
****************************************************************************
FLOW PROCESS FROM NODE 75.10 TO NODE 75.10 IS CODE = 1
»»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
»»>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES««<
TOTAL NUMBER OF STREAMS = 2
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE:
TIME OF CONCENTRATION(MIN.) = 23.78
RAINFALL INTENSITY(INCH/HR) = 2.51
TOTAL STREAM AREA(ACRES) = 3.70
PEAK FLOW RATE(CFS) AT CONFLUENCE = 5.11
^ ** CONFLUENCE DATA **
STREAM RUNOFF Tc INTENSITY AREA
NUMBER (CFS) (MIN.) (INCH/HOUR) (ACRE)
1 3.83 8.51 4.861 2.00
2 5.11 23.78 2.505 3.70
RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO
CONFLUENCE FORMULA USED FOR 2 STREAMS.
** PEAK FLOW RATE TABLE **
STREAM RUNOFF Tc INTENSITY
NUMBER (CFS) (MIN.) (INCH/HOUR)
1 6.46 8.51 4.861
2 7.08 23.78 2.505
COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS:
PEAK FLOW RATE(CFS) = 7.08 Tc(MIN.) = 23.78
TOTAL AREA(ACRES) = 5.70
+ -I-
I WILL USE SHORTER TIME OF CONCENTRATION TO BE CONSERVATIVE j
I Q=6.64CFS, A=4.9AC, TC=8.5MIN I
I I
+ -I-
****************************************************************************
FLOW PROCESS FROM NODE 75.10 TO NODE 75.10 IS CODE = 7
»»>USER SPECIFIED HYDROLOGY INFORMATION AT NODE««<
USER-SPECIFIED VALUES ARE AS FOLLOWS:
TC(MIN) = 8.50 RAIN INTENSITY(INCH/HOUR) = 4.86
TOTAL AREA(ACRES) = 4.90 TOTAL RUNOFF(CFS) = 6.64
I
I ****************************************************************************
FLOW PROCESS FROM NODE 75.10 TO NODE 75.10 IS CODE = 10
»»>MAIN-STREAM MEMORY COPIED ONTO MEMORY BANK # 1 ««<
****************************************************************************
FLOW PROCESS FROM NODE 42.00 TO NODE 42A IS CODE = 21
»»>RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
INITIAL SUBAREA FLOW-LENGTH = 150.00
UPSTREAM ELEVATION = 51.10
DOWNSTREAM ELEVATION = 48.94
ELEVATION DIFFERENCE = 2.16
URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 10.737
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.184
SUBAREA RUNOFF(CFS) = .69
TOTAL AREA(ACRES) = .30 TOTAL RUNOFF(CFS) = .69
****************************************************************************
FLOW PROCESS FROM NODE 42A TO NODE 45.00 IS CODE = 6
>»»COMPUTE STREETFLOW TRAVELTIME THRU SUBAREA««<
UPSTREAM ELEVATION = 48.49 DOWNSTREAM ELEVATION = 47.48
STREET LENGTH(FEET) = 75.00 CURB HEIGHT(INCHES) = 6.
STREET HALFWIDTH(FEET) = 18.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK = 16.50
INTERIOR STREET CROSSFALL(DECIMAL) = .020
OUTSIDE STREET CROSSFALL(DECIMAL) = .083
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF = 1
**TRAVELTIME COMPUTED USING MEAN FLOW(CFS) = 1.02
STREETFLOW MODEL RESULTS:
STREET FLOWDEPTH(FEET) = .24
HALFSTREET FLOODWIDTH(FEET) = 5.88
AVERAGE FLOW VELOCITY(FEET/SEC.) = 2.20
PRODUCT OF DEPTH&VELOCITY = .54
STREETFLOW TRAVELTIME(MIN) = .57 TC(MIN) = 11.30
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.048
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
SUBAREA AREA(ACRES) = .30 SUBAREA RUNOFF(CFS) = .67
SUMMED AREA(ACRES) = .60 TOTAL RUNOFF(CFS) = 1.36
END OF SUBAREA STREETFLOW HYDRAULICS:
DEPTH(FEET) = .26 HALFSTREET FLOODWIDTH(FEET) = 6.91
FLOW VELOCITY(FEET/SEC.) = 2.28 DEPTH*VELOCITY = .60
I
I
I (**************************************************************************
FLOW PROCESS FROM NODE 45.00 TO NODE 45.00 IS CODE = 1
»»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
TOTAL NUMBER OF STREAMS = 2
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE:
TIME OF CONCENTRATION(MIN.) = 11.30
RAINFALL INTENSITY(INCH/HR) = 4.05
TOTAL STREAM AREA(ACRES) = .60
PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.36
****************************************************************************
FLOW PROCESS FROM NODE 43.00 TO NODE 44.00 IS CODE = 21
»»>RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
INITIAL SUBAREA FLOW-LENGTH = 180.00
UPSTREAM ELEVATION = 51.00
DOWNSTREAM ELEVATION = 4 8.90
ELEVATION DIFFERENCE = 2.10
URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 12.617
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.771
SUBAREA RUNOFF(CFS) = .62
TOTAL AREA(ACRES) = .30 TOTAL RUNOFF(CFS) = .62
****************************************************************************
FLOW PROCESS FROM NODE 44.00 TO NODE 45.00 IS CODE = 6
»»>COMPUTE STREETFLOW TRAVELTIME THRU SUBAREA««<
UPSTREAM ELEVATION = 48.90 DOWNSTREAM ELEVATION = 47.48
STREET LENGTH(FEET) = 122.00 CURB HEIGHT(INCHES) = 6.
STREET HALFWIDTH(FEET) = 18.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK = 16.50
INTERIOR STREET CROSSFALL(DECIMAL) = .020
OUTSIDE STREET CROSSFALL(DECIMAL) = .083
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF = 1
**TRAVELTIME COMPUTED USING MEAN FLOW(CFS) = .92
STREETFLOW MODEL RESULTS:
STREET FLOWDEPTH(FEET) = .24
HALFSTREET FLOODWIDTH(FEET) = 5.88
AVERAGE FLOW VELOCITY(FEET/SEC.) = 1.98
PRODUCT OF DEPTH&VELOCITY = .48
STREETFLOW TRAVELTIME(MIN) = 1.03 TC(MIN) = 13.65
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.585
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
SUBAREA AREA{ACRES) = .30 SUBAREA RUNOFF(CFS) = .59
I
I
I
I
I
SUMMED AREA(ACRES) = .60 TOTAL RUNOFF(CFS) = 1.21
END OF SUBAREA STREETFLOW HYDRAULICS:
DEPTH(FEET) = .26 HALFSTREET FLOODWIDTH(FEET) = 6.91
FLOW VELOCITY(FEET/SEC.) = 2.04 DEPTH*VELOCITY = .54
****************************************************************************
FLOW PROCESS FROM NODE 45.00 TO NODE 45.00 IS CODE = 1
»»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
»»>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES««<
TOTAL NUMBER OF STREAMS = 2
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE:
TIME OF CONCENTRATION(MIN.) = 13.65
RAINFALL INTENSITY(INCH/HR) = 3.58
TOTAL STREAM AREA(ACRES) = .60
PEAK FLOW RATE(CFS) AT CONFLUENCE = 1.21
** CONFLUENCE DATA **
STREAM RUNOFF Tc INTENSITY AREA
NUMBER (CFS) (MIN.) (INCH/HOUR) (ACRE)
1 1.36 11.30 4.048 .60
2 1.21 13.65 3.585 .60
RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO
CONFLUENCE FORMULA USED FOR 2 STREAMS.
** PEAK FLOW RATE TABLE **
STREAM RUNOFF Tc INTENSITY
NUMBER (CFS) (MIN.) (INCH/HOUR)
1 2.43 11.30 4.048
2 2.42 13.65 3.585
COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS:
PEAK FLOW RATE(CFS) = 2.43 Tc(MIN.) = 11.30
TOTAL AREA(ACRES) = 1.20
****************************************************************************
FLOW PROCESS FROM NODE 45.00 TO NODE 75.00 IS CODE = 4
»»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
»»>USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 18.0 INCH PIPE IS 7.3 INCHES
PIPEFLOW VELOCITY(FEET/SEC.) = 3.6
UPSTREAM NODE ELEVATION = 4 3.12
DOWNSTREAM NODE ELEVATION = 42.85
FLOWLENGTH(FEET) = 54.38 MANNING'S N = .013
GIVEN PIPE DIAMETER(INCH) = 18.00 NUMBER OF PIPES = 1
PIPEFLOW THRU SUBAREA(CFS) = 2.43
TRAVEL TIME(MIN.) = .25 TC(MIN.) = 11.56
****************************************************************************
FLOW PROCESS FROM NODE 75.00 TO NODE 75.00 IS CODE = 1
I
»»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
TOTAL NUMBER OF STREAMS = 3
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 1 ARE:
TIME OF CONCENTRATION(MIN.) = 11.56
RAINFALL INTENSITY(INCH/HR) = 3.99
TOTAL STREAM AREA(ACRES) = 1.20
PEAK FLOW RATE(CFS) AT CONFLUENCE = 2.43
****************************************************************************
FLOW PROCESS FROM NODE 46.00 TO NODE 47.00 IS CODE = 21
»»>RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
INITIAL SUBAREA FLOW-LENGTH = 150.00
UPSTREAM ELEVATION = 51.00
DOWNSTREAM ELEVATION = 48.90
ELEVATION DIFFERENCE = 2.10
URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 10.839
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 4.159
SUBAREA RUNOFF(CFS) = .46
TOTAL AREA(ACRES) = .20 TOTAL RUNOFF(CFS) = .46
****************************************************************************
FLOW PROCESS FROM NODE 4 6.00 TO NODE 75.00 IS CODE = 6
>»»COMPUTE STREETFLOW TRAVELTIME THRU SUBAREA««<
UPSTREAM ELEVATION = 48.90 DOWNSTREAM ELEVATION = 47.38
STREET LENGTH(FEET) = 130.00 CURB HEIGHT(INCHES) = 6.
STREET HALFWIDTH(FEET) = 18.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK = 16.50
INTERIOR STREET CROSSFALL(DECIMAL) = .020
OUTSIDE STREET CROSSFALL(DECIMAL) = .083
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF = 1
**TRAVELTIME COMPUTED USING MEAN FLOW(CFS) = .67
STREETFLOW MODEL RESULTS:
STREET FLOWDEPTH(FEET) = .22
HALFSTREET FLOODWIDTH{FEET) = 4.85
AVERAGE FLOW VELOCITY(FEET/SEC.) = 1.90
PRODUCT OF DEPTH&VELOCITY = .42
STREETFLOW TRAVELTIME(MIN) = 1.14 TC(MIN) = 11.98
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 3.899
SOIL CLASSIFICATION IS "D"
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5500
SUBAREA AREA(ACRES) = .20 SUBAREA RUNOFF(CFS) = .43
SUMMED AREA(ACRES) = .40 TOTAL RUNOFF(CFS) = .89
END OF SUBAREA STREETFLOW HYDRAULICS:
10
DEPTH(FEET) = .24 HALFSTREET FLOODWIDTH(FEET) = 5.88
FLOW VELOCITY(FEET/SEC.) = 1.91 DEPTH*VELOCITY = .47
****************************************************************************
FLOW PROCESS FROM NODE 75.00 TO NODE 75.00 IS CODE = 1
»>»DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
TOTAL NUMBER OF STREAMS = 3
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 2 ARE:
TIME OF CONCENTRATION(MIN.) = 11.98
RAINFALL INTENSITY(INCH/HR) = 3.90
TOTAL STREAM AREA(ACRES) = .40
PEAK FLOW RATE(CFS) AT CONFLUENCE = .89
****************************************************************************
FLOW PROCESS FROM NODE 50.00 TO NODE 60.00 IS CODE = 21
»»>RATIONAL METHOD INITIAL SUBAREA ANALYSIS««<
*USER SPECIFIED(SUBAREA):
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .9500
INITIAL SUBAREA FLOW-LENGTH = 150.00
UPSTREAM ELEVATION = 52.00
DOWNSTREAM ELEVATION = 50.00
ELEVATION DIFFERENCE = 2.00
URBAN SUBAREA OVERLAND TIME OF FLOW(MINUTES) = 3.004
" TIME OF CONCENTRATION ASSUMED AS 6-MINUTES
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 6.090
SUBAREA RUNOFF(CFS) = .58
TOTAL AREA(ACRES) = .10 TOTAL RUNOFF(CFS) = .58
****************************************************************************
FLOW PROCESS FROM NODE 60.00 TO NODE 70.00 IS CODE = 6
»»>COMPUTE STREETFLOW TRAVELTIME THRU SUBAREA««<
UPSTREAM ELEVATION = 50.00 DOWNSTREAM ELEVATION = 4 8.85
STREET LENGTH(FEET) = 80.00 CURB HEIGHT(INCHES) = 6.
STREET HALFWIDTH(FEET) =32.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK = 30.50
INTERIOR STREET CROSSFALL(DECIMAL) = .020
OUTSIDE STREET CROSSFALL(DECIMAL) = .083
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF = 1
**TRAVELTIME COMPUTED USING MEAN FLOW(CFS) = 1.17
STREETFLOW MODEL RESULTS:
STREET FLOWDEPTH(FEET) = .26
HALFSTREET FLOODWIDTH(FEET) = 6.7 4
AVERAGE FLOW VELOCITY(FEET/SEC.) = 2.04
PRODUCT OF DEPTH&VELOCITY = .53
STREETFLOW TRAVELTIME(MIN) = .65 TC(MIN) = 6.65
11
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.697
*USER SPECIFIED(SUBAREA):
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .5100
SUBAREA AREA(ACRES) = .40 SUBAREA RUNOFF(CFS) = 1.16
SUMMED AREA(ACRES) = .50 TOTAL RUNOFF(CFS) = 1.74
END OF SUBAREA STREETFLOW HYDRAULICS:
DEPTH(FEET) = .28 HALFSTREET FLOODWIDTH(FEET) = 7.70
FLOW VELOCITY(FEET/SEC.) = 2.4 5 DEPTH*VELOCITY = .69
****************************************************************************
FLOW PROCESS FROM NODE 71.00 TO NODE 75.00 IS CODE = 6
»»>COMPUTE STREETFLOW TRAVELTIME THRU SUBAREA««<
UPSTREAM ELEVATION = 48.85 DOWNSTREAM ELEVATION = 47.38
STREET LENGTH(FEET) = 154.00 CURB HEIGHT(INCHES) = 6.
STREET HALFWIDTH(FEET) = 18.00
DISTANCE FROM CROWN TO CROSSFALL GRADEBREAK = 16.50
INTERIOR STREET CROSSFALL(DECIMAL) = .020
OUTSIDE STREET CROSSFALL(DECIMAL) = .083
SPECIFIED NUMBER OF HALFSTREETS CARRYING RUNOFF = 1
**TRAVELTIME COMPUTED USING MEAN FLOW(CFS) = 1.98
STREETFLOW MODEL RESULTS:
STREET FLOWDEPTH(FEET) = .31
HALFSTREET FLOODWIDTH(FEET) = 8.98
AVERAGE FLOW VELOCITY(FEET/SEC.) = 2.15
PRODUCT OF DEPTH&VELOCITY = .66
STREETFLOW TRAVELTIME(MIN) = 1.20 TC(MIN) = 7.85
100 YEAR RAINFALL INTENSITY(INCH/HOUR) = 5.121
*USER SPECIFIED(SUBAREA):
SINGLE FAMILY DEVELOPMENT RUNOFF COEFFICIENT = .9500
SUBAREA AREA(ACRES) = .10 SUBAREA RUNOFF(CFS) = .49
SUMMED AREA(ACRES) = .60 TOTAL RUNOFF(CFS) = 2.23
END OF SUBAREA STREETFLOW HYDRAULICS:
DEPTH(FEET) = .32 HALFSTREET FLOODWIDTH(FEET) = 9.4 9
FLOW VELOCITY(FEET/SEC.) = 2.19 DEPTH&VELOCITY = .69
****************************************************************************
FLOW PROCESS FROM NODE 75.00 TO NODE 75.00 IS CODE = 1
»»>DESIGNATE INDEPENDENT STREAM FOR CONFLUENCE««<
»»>AND COMPUTE VARIOUS CONFLUENCED STREAM VALUES««<
TOTAL NUMBER OF STREAMS = 3
CONFLUENCE VALUES USED FOR INDEPENDENT STREAM 3 ARE:
TIME OF CONCENTRATION(MIN.) = 7.85
RAINFALL INTENSITY(INCH/HR) = 5.12
TOTAL STREAM AREA(ACRES) = .60
PEAK FLOW RATE(CFS) AT CONFLUENCE = 2.23
12
** CONFLUENCE DATA **
STREAM
NUMBER
1
2
3
RUNOFF
(CFS)
2.43
.89
2.23
Tc
(MIN.)
11.56
11.98
7.85
INTENSITY
(INCH/HOUR)
3. 991
3.899
5.121
AREA
(ACRE)
1.20
.40
.60
RAINFALL INTENSITY AND TIME OF CONCENTRATION RATIO
CONFLUENCE FORMULA USED FOR 3 STREAMS.
** PEAK FLOW RATE TABLE **
STREAM
NUMBER
1
2
3
RUNOFF
(CFS)
4.80
5.04
4.96
Tc
(MIN.)
7.85
11.56
11.98
INTENSITY
(INCH/HOUR)
5.121
3. 991
3.899
COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS:
PEAK FLOW RATE(CFS) = 5.04 Tc(MIN.) =
TOTAL AREA(ACRES) = 2.20
11.56
****************************************************************************
FLOW PROCESS FROM NODE 75.00 TO NODE 75.10 IS CODE =
»»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
»»>USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 18.0 INCH PIPE IS 11.0
PIPEFLOW VELOCITY(FEET/SEC.) = 4.5
UPSTREAM NODE ELEVATION = 42.52
DOWNSTREAM NODE ELEVATION =
FLOWLENGTH(FEET) = 170.84
GIVEN PIPE DIAMETER(INCH) =
PIPEFLOW THRU SUBAREA{CFS) =
TRAVEL TIME(MIN.) = .64
INCHES
41.60
MANNING'S N = .013
18.00 NUMBER OF PIPES
5.04
TC(MIN.) = 12.19
****************************************************************************
FLOW PROCESS FROM NODE 75.10 TO NODE 75.10 IS CODE = 11
»»>CONFLUENCE MEMORY BANK # 1 WITH THE MAIN-STREAM MEMORY««<
** MAIN STREAM CONFLUENCE DATA
STREAM
NUMBER
1
RUNOFF
(CFS)
5.04
Tc
(MIN.)
12.19
INTENSITY
(INCH/HOUR)
3.855
AREA
(ACRE)
2.20
** MEMORY BANK #
STREAM RUNOFF
NUMBER (CFS)
1 6.64
1 CONFLUENCE DATA **
Tc INTENSITY AREA
(MIN.) (INCH/HOUR) (ACRE)
8.50 4.865 4.90
PEAK FLOW RATE TABLE
STREAM
NUMBER
RUNOFF
(CFS)
Tc
(MIN.)
INTENSITY
(INCH/HOUR)
13
1 10.63 8.50 4.865
2 10.30 12.19 3.855
COMPUTED CONFLUENCE ESTIMATES ARE AS FOLLOWS:
PEAK FLOW RATE(CFS) = 10.63 Tc(MIN.) = 8.50
TOTAL AREA(ACRES) = 7.10
****************************************************************************
FLOW PROCESS FROM NODE 75.10 TO NODE 75.20 IS CODE = 4
»»>COMPUTE PIPEFLOW TRAVELTIME THRU SUBAREA««<
»»>USING USER-SPECIFIED PIPESIZE««<
DEPTH OF FLOW IN 24.0 INCH PIPE IS 11.0 INCHES
PIPEFLOW VELOCITY(FEET/SEC.) = 7.5
UPSTREAM NODE ELEVATION = 41.46
DOWNSTREAM NODE ELEVATION = 38.55
FLOWLENGTH(FEET) = 221.88 MANNING'S N = .013
GIVEN PIPE DIAMETER(INCH) = 24.00 NUMBER OF PIPES = 1
PIPEFLOW THRU SUBAREA(CFS) = 10.63
TRAVEL TIME(MIN.) = .49 TC(MIN.) = 8.99
END OF STUDY SUMMARY:
PEAK FLOW RATE(CFS) = 10.63 Tc(MIN.) = 8.99
TOTAL AREA(ACRES) = 7.10
END OF RATIONAL METHOD ANALYSIS
14
II. CALCULATIONS
C. HYDRAULIC GRADE LINE ANALYSIS
******************************************************************************
PIPE-FLOW HYDRAULICS COMPUTER PROGRAM PACKAGE
(Reference: LACFCD,LACRD, AND OCEMA HYDRAULICS CRITERION)
(c) Copyright 1982-98 Advanced Engineering Software (aes)
Ver. 7.1 Release Date: 01/01/98 License ID 1459
Analysis prepared by:
BHA
5115 AVENIDA ENCINAS
SUITE L
CARLSBAD, CA 92008
************************** DESCRIPTION OF STUDY **************************
* HYDRAULIC GRADE LINE ANALYSIS - NODE 75.1 TO 45 *
* *
* *
**************************************************************************
FILE NAME: 810-P3.DAT
TIME/DATE OF STUDY: 12:45 9/14/2002
******************************************************************************
GRADUALLY VARIED FLOW ANALYSIS FOR PIPE SYSTEM
NODAL POINT STATUS TABLE
(Note: "*" indicates nodal point data used.)
UPSTREAM RUN DOWNSTREAM RUN
NODE MODEL PRESSURE PRESSURE+ FLOW PRESSURES-
NUMBER PROCESS HEAD(FT) MOMENTUM(POUNDS) DEPTH(FT) MOMENTUM(POUNDS)
75.20- 1.17 Dc 174.76 .89* 193.26
} FRICTION
75.10- 1.17*Dc 174.76 1.17*Dc 174.76
} JUNCTION
75.10- 1.17* 81.96 .86 Dc 71.15
} FRICTION
75.00- 1.57* 118.81 .86 Dc 71.15
} JUNCTION
75.00- 1.53* 92.30 .59 Dc 27.65
} FRICTION
45.00- 1.28* 66.31 .59 Dc 27.65
} CATCH BASIN
45.00- 1.38* 65.80 .59 Dc 9.92
MAXIMUM NUMBER OF ENERGY BALANCES USED IN EACH PROFILE = 25
NOTE: STEADY FLOW HYDRAULIC HEAD-LOSS COMPUTATIONS BASED ON THE MOST
CONSERVATIVE FORMULAE FROM THE CURRENT LACRD,LACFCD, AND OCEMA
DESIGN MANUALS.
******************************************************************************
DOWNSTREAM PIPE FLOW CONTROL DATA:
NODE NUMBER = 75.20 FLOWLINE ELEVATION = 38.55
PIPE FLOW = 10.63 CFS PIPE DIAMETER = 24.00 INCHES
ASSUMED DOWNSTREAM CONTROL HGL = 39.470
*NOTE: ASSUMED DOWNSTREAM CONTROL DEPTH( .92 FT.)
IS LESS THAN CRITICAL DEPTH( 1.17 FT.)
===> CRITICAL DEPTH IS ASSUMED AS DOWNSTREAM CONTROL DEPTH
FOR UPSTREAM RUN ANALYSIS
NODE 75.20 : HGL = < 39.442>;EGL= < 40.397>;FLOWLINE= < 38.550>
******************************************************************************
FLOW PROCESS FROM NODE 75.20 TO NODE 75.10 IS CODE = 1
UPSTREAM NODE 75.10 ELEVATION = 41.46 (FLOW IS SUPERCRITICAL)
CALCULATE FRICTION LOSSES(LACFCD):
PIPE FLOW = 10.63 CFS
PIPE LENGTH = 221.88 FEET
PIPE DIAMETER = 24.00 INCHES
MANNING'S N = .01300
NORMAL DEPTH(FT) .89 CRITICAL DEPTH(FT) 1.17
UPSTREAM ::ONTROL ASSUMED FLOWDEPTH(FT) 1.17
GRADUALLY VARIED FLOW PROFILE COMPUTED INFORMATION:
DISTANCE FROM FLOW DEPTH VELOCITY SPECIFIC PRESSURE-I-
CONTROL(FT) (FT) (FT/SEC) ENERGY(FT) MOMENTUM (POUNDS)
.000 1.168 5 577 1.651 174 . 76
.026 1.157 5 641 1.652 174. 78
.108 1.146 5 707 1. 652 174. 86
.252 1.135 5 775 1.653 174. 98
.462 1.124 5 845 1. 655 175. 15
.746 1.113 5 916 1. 657 175. 37
1 .113 1.102 5 989 1. 659 175. 65
1 .570 1.091 6 064 1. 662 175. 99
2 .130 1.080 6 141 1.666 176. 37
2 .805 1.069 6 220 1.670 176. 82
3 . 611 1.058 6 301 1.675 177. 33
4 .565 1.047 6 385 1.680 177. 89
5 .692 1.036 6 471 1.686 178. 52
7 .018 1.025 6 559 1.693 179. 21
8 .580 1.014 6 649 1.701 179. 97
10 .424 1.003 6 742 1.709 180. 79
12 .610 .992 6 838 1.718 181. 69
15 .220 . 981 6 936 1.728 182. 66
18 .369 . 970 7 038 1.739 183. 70
22 .225 . 959 7 142 1.751 184 . 81
27 .048 .948 7 249 1.764 186. 01
33 .276 .936 7 360 1.778 187. 29
41 .728 .925 7 474 1.793 188. 65
54 .245 . 914 7 591 1.810 190. 10
76 .735 . 903 7 712 1.828 191. 63
221 .880 .892 7 837 1.847 193. 26
NODE 75.10 HGL 42.628>;EGL= < 43.111>;FLOWLINE= < 41.460>
******************************************************************************
FLOW PROCESS FROM NODE
UPSTREAM NODE 75.10
75.10 TO NODE
ELEVATION =
75.10 IS CODE = 5
42.52 (FLOW IS AT CRITICAL DEPTH)
CALCULATE JUNCTION LOSSES:
PIPE FLOW DIAMETER ANGLE FLOWLINE CRITICAL VELOCITY
(CFS) (INCHES) (DEGREES) ELEVATION DEPTH(FT.) (FT/SEC)
UPSTREAM 5.04 18.00 90.00 42.52 .86
DOWNSTREAM 10.63 24.00 - 41.46 1.17
LATERAL #1 3.19 18.00 90.00 41.66 .68
LATERAL #2 2.40 18.00 .00 41.66 .59
Q5 .00===Q5 EQUALS BASIN INPUT===
3.411
5.579
1.805
1.358
LACFCD AND OCEMA FLOW JUNCTION FORMULAE USED:
DY=(Q2*V2-Q1*V1*C0S(DELTAl)-Q3*V3*COS(DELTA3)-
Q4 *V4 *COS (DELTA4 ) ) / ( (A1-I-A2) * 16.1) -I-FRICTION LOSSES
UPSTREAM: MANNING'S N = .01300; FRICTION SLOPE =
DOWNSTREAM: MANNING'S N = .01300; FRICTION SLOPE =
AVERAGED FRICTION SLOPE IN JUNCTION ASSUMED AS .00393
JUNCTION LENGTH = 4.00 FEET
FRICTION LOSSES = .016 FEET ENTRANCE LOSSES =
JUNCTION LOSSES = (DY-fHVl-HV2)-I-(ENTRANCE LOSSES)
JUNCTION LOSSES = ( .758)-l-( .000) = .758
,00254
,00532
.000 FEET
NODE 75.10 : HGL = < 43.689>;EGL= < 43.870>;FLOWLINE= < 42.520>
******************************************************************************
FLOW PROCESS FROM NODE
UPSTREAM NODE 75.00
75.10 TO NODE
ELEVATION =
75.00 IS CODE = 1
42.52 (FLOW UNSEALS IN REACH)
CALCULATE FRICTION LOSSES(LACFCD):
PIPE FLOW = 5.04 CFS PIPE DIAMETER = 18.00 INCHES
PIPE LENGTH = 170.84 FEET MANNING'S N = .01300
•WARNING — PIPE INVERT SLOPE IS LESS THAN .0001, AND DEFAULTED TO .0001
===> NORMAL PIPEFLOW IS PRESSURE FLOW
NORMAL DEPTH(FT) = 1.50 CRITICAL DEPTH(FT) =
DOWNSTREAM CONTROL ASSUMED FLOWDEPTH(FT) = 1.17
.86
GRADUALLY VARIED FLOW PROFILE COMPUTED INFORMATION:
DISTANCE FROM
CONTROL(FT)
.000
3.859
7.890
12.091
16.459
20.993
25.688
30.542
35.549
40.707
46.009
51.449
57.022
62.720
68.536
74.461
80.486
86.600
92.792
FLOW DEPTH
(FT)
VELOCITY
(FT/SEC)
SPECIFIC
ENERGY(FT)
169
182
195
209
222
235
248
262
275
288
301
315
328
341
354
368
381
394
407
,410
,373
,337
,302
,269
.237
.206
,176
,147
,120
,094
,069
,045
,022
3.001
2.980
2.961
2.943
2.926
,350
. 359
,368
,378
.388
.398
.408
.418
,429
.439
,450
1.461
1.472
,483
.494
,506
,517
,529
,540
PRESSURE-I-
MOMENTUM (POUNDS)
81.96
82.82
83.71
84.62
85.56
86.53
87.52
88.54
89.58
90.64
91.72
92.83
93.96
95.11
96.28
97.47
98.69
99.92
101.17
99.049 1.421 2. 910 1.552 102.45
105.357 1.434 2.896 1.564 103.74
111.698 1.447 2.883 1.576 105.06
118.054 1.460 2.872 1.588 106.39
124.399 1.474 2.863 1.601 107.75
130.699 1.487 2.855 1.613 109.14
136.876 1.500 2.851 1.626 110.56
===> FLOW IS UNDER PRESSURE
170.840 1.575 2.852 1.701 118.81
NODE 75.00 : HGL = < 44 095>;EGL= < 44.221>;FLOWLINE= < 42.520
******************************************************************************
FLOW PROCESS FROM NODE 75.00 TO NODE 75.00 IS CODE = 5
UPSTREAM NODE 75.00 ELEVATION = 42.85 (FLOW IS UNDER PRESSURE)
CALCULATE JUNCTION LOSSES:
PIPE FLOW DIAMETER ANGLE
(CFS) (INCHES) (DEGREES) ELEVATION
UPSTREAM 2.43 18.00 90.00 42.85
DOWNSTREAM 5.04 18.00 - 42.52
LATERAL #1 .00 .00 .00 .00
LATERAL #2 .00 .00 .00 .00
Q5 2.61===Q5 EQUALS BASIN INPUT===
FLOWLINE CRITICAL VELOCITY
DEPTH(FT.) (FT/SEC)
.59 1.375
.86 2.852
.00 .000
.00 .000
LACFCD AND OCEMA FLOW JUNCTION FORMULAE USED:
DY=(Q2*V2-Q1*V1*C0S(DELTAl)-Q3*V3*COS(DELTA3)-
Q4*V4*COS(DELTA4) )/( (A1-I-A2) *16.1)-t-FRICTION LOSSES
UPSTREAM: MANNING'S N = .01300; FRICTION SLOPE = .
DOWNSTREAM: MANNING'S N = .01300; FRICTION SLOPE = .
AVERAGED FRICTION SLOPE IN JUNCTION ASSUMED AS .00142
JUNCTION LENGTH = 4.00 FEET
FRICTION LOSSES = .006 FEET ENTRANCE LOSSES =
JUNCTION LOSSES = (DY-i-HVI-HV2)-)-(ENTRANCE LOSSES)
JUNCTION LOSSES = ( .161)-i-i .025) = .187
00054
00230
.025 FEET
NODE 75.00 : HGL = < 44.378>;EGL= < 44.408>;FLOWLINE= < 42.850>
******************************************************************************
FLOW PROCESS FROM NODE 75.00 TO NODE 45.00 IS CODE = 1
UPSTREAM NODE 4 5.00 ELEVATION = 43.12 (FLOW SEALS IN REACH)
CALCULATE FRICTION LOSSES(LACFCD):
PIPE FLOW = 2.4 3 CFS
PIPE LENGTH = 54.38 FEET
PIPE DIAMETER =
MANNING'S N =
18.00 INCHES
.01300
DOWNSTREAM CONTROL ASSUMED PRESSURE HEAD(FT) = 1.53
PRESSURE FLOW PROFILE COMPUTED INFORMATION:
DISTANCE FROM PRESSURE VELOCITY SPECIFIC PRESSURE-t-
CONTROL(FT) HEAD(FT) (FT/SEC) ENERGY(FT) MOMENTUM (POUNDS)
.000 1.528 1.375 1.558 92.30
6.399 1.500 1.375 1.529 89.18
NORMAL DEPTH(FT) = .59 CRITICAL DEPTH(FT) .59
ASSUMED DOWNSTREAM PRESSURE HEAD(FT) = 1.50
GRADUALLY VARIED FLOW PROFILE COMPUTED INFORMATION:
DISTANCE FROM .FLOW DEPTH VELOCITY SPECIFIC PRESSURE-^
CONTROL(FT) (FT) (FT/SEC) ENERGY( FT) MOMENTUM(POUNDS)
6.399 1.500 1.375 1. 529 89.18
14.447 1.464 1.383 1. 493 85.22
22.373 1.427 1.400 1. 458 81.34
30.238 1.391 1.421 1. 422 77.53
38.061 1.355 1.447 1. 387 73.81
45.853 1.318 1.476 1. 352 70.18
53.622 1.282 1.510 1. 317 66.65
54.380 1.278 1.514 1. 314 66.31
NODE 45.00 : HGL = < 44. 398>;EGL= < 44.434>;FLOWLINE= < 43.120>
******************************************************************************
FLOW PROCESS FROM NODE 45. 00 TO NODE 45.00 IS CODE = 8
UPSTREAM NODE 45.00 ELEVATION = 43.06 (FLOW IS SUBCRITICAL)
CALCULATE CATCH BASIN ENTRANCE LOSSES(LACFCD):
PIPE FLOW = 2.43 CFS PIPE DIAMETER = 18 .00 INCHES
FLOW VELOCITY = 1.51 FEET/SEC. VELOCITY HEAD = 036 FEET
CATCH BASIN ENERGY LOSS = .2* (VELOCITY HEAD) = .2*( • 036) = .007
NODE 45.00 : HGL = < 44. 441>;EGL= < 44.441>;FLOWLINE= < 43.060>
******************************************************************************
UPSTREAM PIPE FLOW CONTROL DATA:
NODE NUMBER = 45.00
ASSUMED UPSTREAM CONTROL HGL =
FLOWLINE ELEVATION = 43.06
43.65 FOR DOWNSTREAM RUN ANALYSIS
END OF GRADUALLY VARIED FLOW ANALYSIS
******************************************************************************
PIPE-FLOW HYDRAULICS COMPUTER PROGRAM PACKAGE
(Reference: LACFCD, LACRD, mD OCEMA HYDRAULICS CRITERION)
(c) Copyright 1982-98 Advanced Engineering Software (aes)
Ver. 7.1 Release Date: 01/01/98 License ID 1459
Analysis prepared by:
BHA
5115 AVENIDA ENCINAS
SUITE L
CARLSBAD, CA 92008
************************** DESCRIPTION OF STUDY **************************
* HYDRAULIC GRADE LINE ANALYSIS NODE 75.1 TO 4 0.0 *
* *
* *
**************************************************************************
FILE NAME: 810-P2.DAT
TIME/DATE OF STUDY: 12:58 9/14/2002
******************************************************************************
GRADUALLY VARIED FLOW ANALYSIS FOR PIPE SYSTEM
NODAL POINT STATUS TABLE
(Note: "*" indicates nodal point data used.)
UPSTREAM RUN DOWNSTREAM RUN
NODE MODEL PRESSURE PRESSURE-l- FLOW PRESSURE-I-
NUMBER PROCESS HEAD(FT) MOMENTUM(POUNDS) DEPTH(FT) MOMENTUM(POUNDS)
75.10- 2.03* 169.78 .75 75.03
) FRICTION
41.10- 1.24* 87.67 .87 Dc 72.45
} JUNCTION
41.10- 1.48* 85.04 .37 23.90
} FRICTION } HYDRAULIC JUMP
40.10- .66 22.32 .35* 25.72
} JUNCTION
40.10- .52 Dc 20.32 .35* 25.10
} FRICTION
40.00- .52*Dc 20.32 .52*Dc 20.32
} CATCH BASIN
40.00- .75* 10.82 .52 Dc 7.35
MAXIMUM NUMBER OF ENERGY BALANCES USED IN EACH PROFILE = 25
NOTE: STEADY FLOW HYDRAULIC HEAD-LOSS COMPUTATIONS BASED ON THE MOST
CONSERVATIVE FORMULAE FROM THE CURRENT LACRD,LACFCD, AND OCEMA
DESIGN MANUALS.
******************************************************************************
DOWNSTREAM PIPE FLOW CONTROL DATA:
NODE NUMBER = 75.10 FLOWLINE ELEVATION = 41.66
PIPE FLOW = 5.11 CFS PIPE DIAMETER = 18.00 INCHES
ASSUMED DOWNSTREAM CONTROL HGL = 4 3.690
NODE 75.10 HGL 43.690>;EGL= < 43.820>;FLOWLINE= < 41.660>
******************************************************************************
FLOW PROCESS FROM NODE 75.10 TO NODE 41.10 IS CODE = 1
UPSTREAM NODE 41.10 ELEVATION = 42.65 (FLOW SEALS IN REACH)
CALCULATE FRICTION LOSSES(LACFCD):
PIPE FLOW = 5.11 CFS
PIPE LENGTH = 102.34 FEET
PIPE DIAMETER = 18.00 INCHES
MANNING'S N = .01300
DOWNSTREAM CONTROL ASSUMED PRESSURE HEAD(FT) =
PRESSURE FLOW PROFILE COMPUTED INFORMATION:
2.03
DISTANCE FROM
CONTROL(FT)
PRESSURE
HEAD(FT)
VELOCITY
(FT/SEC)
SPECIFIC
ENERGY(FT)
PRESSURE-I-
MOMENTUM (POUNDS)
.000 2 .030 2 892 2.160 169.78
72.531 1 .500 2 892 1.630 111.34
NORMAL DEPTH(FT) = .75 CRITICAL DEPTH(FT) = .87
ASSUMED DOWNSTREAM PRESSURE HEAD(FT) 1.50
GRADUALLY VARIED FLOW PROFILE COMPUTED INFORMATION:
DISTANCE FROM FLOW DEPTH VELOCITY SPECIFIC PRESSURE-1-
CONTROL(FT) (FT) (FT/SEC) ENERGY(FT) MOMENTUM(POUNDS)
72.531 1 .500 2 891 1. 630 111.34
75.786 1 .475 2 901 1. 606 108.67
78.880 1 .450 2 921 1.582 106.10
81.884 1 .424 2 946 1.559 103.62
84.820 1 .399 2 977 1.537 101.21
87.697 1 .374 3 012 1.515 98.87
90.524 1 .349 3 051 1.493 96.61
93.303 1 .324 3 095 1.472 94.43
96.035 1 .298 3 143 1.452 92.33
98.723 1 .273 3 195 1.432 90.31
101.365 1 .248 3 251 1.412 88.37
102.340 1 .239 3 273 1.405 87.67
NODE 41.10 : HGL = < 43.E 389>;EGL= < 44.055>;FLOWLINE= < 42.650>
******************************************************************************
FLOW PROCESS FROM NODE
UPSTREAM NODE 41.10
41.10 TO NODE
ELEVATION =
41.10 IS CODE = 5
42.69 (FLOW IS SUBCRITICAL)
CALCULATE JUNCTION LOSSES:
FLOWLINE
ELEVATION
PIPE FLOW DIAMETER ANGLE
(CFS) (INCHES) (DEGREES)
UPSTREAM 1.91 18.00 .00 42.69
DOWNSTREAM 5.11 18.00 - 42.65
LATERAL #1 3.20 18.00 90.00 42.69
LATERAL #2 .00 .00 .00 .00
Q5 .00===Q5 EQUALS BASIN INPUT===
LACFCD AND OCEMA FLOW JUNCTION FORMULAE USED:
DY=(Q2*V2-Q1*V1*C0S(DELTAl)-Q3*V3*COS(DELTA3)-
CRITICAL VELOCITY
DEPTH(FT.) (FT/SEC)
,52
,87
,68
,00
1.083
3.274
1. 919
.000
Q4*V4*COS (DELTA4) ) / ( (AH-A2) *16.1)-t-FRICTION LOSSES
UPSTREAM: MANNING'S N = .01300; FRICTION SLOPE = .00030
DOWNSTREAM: MANNING'S N = .01300; FRICTION SLOPE = .00234
AVERAGED FRICTION SLOPE IN JUNCTION ASSUMED AS .00132
JUNCTION LENGTH = 4.00 FEET
FRICTION LOSSES = .005 FEET ENTRANCE LOSSES = .000 FEET
JUNCTION LOSSES = (DY-(-HVl-HV2)-I-(ENTRANCE LOSSES)
JUNCTION LOSSES = ( .138)-l-( .000) = .138
NODE 41.10 : HGL = < 44.175>;EGL= < 44.193>;FLOWLINE= < 42.690>
************ ******************************************************************
FLOW PROCESS FROM NODE 41.10 TO NODE 40.10 IS CODE = 1
UPSTREAM NODE 40.10 ELEVATION = 43.46 (HYDRAULIC JUMP OCCURS)
CALCULATE FRICTION LOSSES(LACFCD):
PIPE FLOW = 1.91 CFS
PIPE LENGTH = 4 3.46 FEET
PIPE DIAMETER = 18.00 INCHES
MANNING'S N = .01300
HYDRAULIC JUMP: DOWNSTREAM RUN ANALYSIS RESULTS
NORMAL DEPTH(FT) = .37 CRITICAL DEPTH(FT) =
UPSTREAM CONTROL ASSUMED FLOWDEPTH(FT) = .35
.52
GRADUALLY VARIED FLOW PROFILE COMPUTED INFORMATION:
DISTANCE FROM
CONTROL(FT)
.000
.690
1.404
2.144
2.912
3.712
4 .545
5.418
6.332
7.294
8.311
9.388
10.536
11.766
13.092
14.532
16.111
17.861
19.828
22.080
24.720
27.923
32.017
37.737
43.460
FLOW DEPTH
(FT)
.345
.346
.347
.349
.350
.351
.352
.353
.354
.356
.357
.358
.359
.360
.362
.363
.364
.365
.366
.367
.369
.370
.371
.372
.373
VELOCITY
(FT/SEC)
6.216
6.186
6.157
6.127
6.098
6.069
6.040
6.012
5.984
5. 956
5.928
5. 901
5.873
5.846
5.819
5.793
5.766
5.740
5.714
5.688
5.663
5.637
5.612
5.587
5.573
SPECIFIC
ENERGY(FT)
.945
.941
.936
.932
.928
.923
.919
.915
. 911
. 907
. 903
.899
.895
.891
.888
.884
.881
. 877
.874
.870
.867
.864
.860
.857
.855
PRESSURE-t-
MOMENTUM (POUNDS)
25.72
25.63
25.55
25.46
25.38
25.29
25.21
25.13
25.05
24.96
24 . 89
24 .81
24 .73
24.65
24.58
24.50
24.43
24.36
24 .29
24.22
24.14
24.08
24.01
23. 94
23.90
HYDRAULIC JUMP: UPSTREAM RUN ANALYSIS RESULTS
DOWNSTREAM CONTROL ASSUMED FLOWDEPTH(FT) = 1.48
GRADUALLY VARIED FLOW PROFILE COMPUTED INFORMATION:
DISTANCE FROM FLOW DEPTH VELOCITY SPECIFIC PRESSURE-t-
CONTROL(FT) (FT) (FT/SEC) ENERGY(FT) MOMENTUM (POUNDS)
.000 1.485 1. 082 1.503 85.04
2.193 1.446 1. 093 1.465 80.85
4 .375 1.408 1. 109 1.427 76.74
6.549 1.369 1. 129 1.389 72.70
8.714 1.331 1. 152 1.351 68.76
10.872 1.292 1. 179 1.314 64.91
13.021 1.253 1. 210 1.276 61.18
15.163 1.215 1. 245 1.239 57.57
17.296 1.176 1. 284 1.202 54.08
19.418 1.138 1. 328 1.165 50.72
21.529 1.099 1. 376 1.129 47.50
23.626 1.061 1. 429 1.092 44.42
25.708 1.022 1. 489 1.056 41.48
27.771 .983 1. 555 1.021 38.71
29.811 .945 1. 628 .986 36.09
31.825 . 906 1. 710 .952 33.64
33.804 .868 1. 802 . 918 31.36
35.742 .829 1. 905 .886 29.26
37.628 .791 2. 022 .854 27.35
39.446 .752 2. 154 .824 25.64
41.175 .713 2. 304 .796 24.13
42.787 . 675 2. 476 .770 22.84
43.460 .657 2. 565 .759 22.32
HYDRAULIC JUMP aMaivcTC — HYDRAULIC JUMP
1 PRESSURE-fMOMENTUM BALANCE OCCURS AT 39.8 3 FEET UPSTREAM OF NODE 41.10 1
NODE
DOWNSTREAM DEPTH = .743 FEET, UPSTREAM CONJUGATE DEPTH = .351 FEET j
40.10 : HGL = < 43.805>;EGL= < 44.405>;FLOWLINE= < 43.460>
******************************************************************************
FLOW PROCESS FROM NODE
UPSTREAM NODE 4 0.10
40.10 TO NODE
ELEVATION =
40.10 IS CODE = 5
43.66 (FLOW IS SUPERCRITICAL)
FLOWLINE
ELEVATION
CALCULATE JUNCTION LOSSES:
PIPE FLOW DIAMETER ANGLE
(CFS) (INCHES) (DEGREES)
UPSTREAM 1.91 18.00 .00 43.66
DOWNSTREAM 1.91 18.00 - 43.46
LATERAL #1 .00 .00 .00 .00
LATERAL #2 .00 .00 .00 .00
Q5 .00===Q5 EQUALS BASIN INPUT===
CRITICAL
DEPTH(FT.)
.52
.52
.00
.00
VELOCITY
(FT/SEC)
6.005
6.218
.000
.000
LACFCD AND OCEMA FLOW JUNCTION FORMULAE USED:
DY=(Q2*V2-Q1*V1*C0S(DELTAl)-Q3*V3*COS(DELTA3)-
Q4*V4*COS (DELTA4) ) / ( (A1-I-A2 )* 16 . 1) -l-FRICTION LOSSES
UPSTREAM: MANNING'S N = .01300; FRICTION SLOPE = .02224
DOWNSTREAM: MANNING'S N = .01300; FRICTION SLOPE = .02454
AVERAGED FRICTION SLOPE IN JUNCTION ASSUMED AS .02339
JUNCTION LENGTH = 4.00 FEET
FRICTION LOSSES = .094 FEET ENTRANCE LOSSES = .000 FEET
JUNCTION LOSSES = (DY-t-HVl-HV2)-I-(ENTRANCE LOSSES)
JUNCTION LOSSES = ( .168)-l-( .000) = .168
NODE 40.10 : HGL = < 44.014>;EGL= < 44.574>;FLOWLINE= < 43.660>
******************************************************************************
FLOW PROCESS FROM NODE
UPSTREAM NODE 40.00
40.10 TO NODE 40.00 IS CODE = 1
ELEVATION = 44.36 (FLOW IS SUPERCRITICAL)
CALCULATE FRICTION LOSSES(LACFCD)
PIPE FLOW = 1.91 CFS
PIPE LENGTH = 28.69 FEET
PIPE DIAMETER = 18.00 INCHES
MANNING'S N = .01300
NORMAL DEPTH(FT) .35 CRITICAL DEPTH(FT) .52
UPSTREAM CONTROL ASSUMED FLOWDEPTH(FT) .52
GRADUALLY VARIED FLOW PROFILE COMPUTED INFORMATION:
DISTANCE FROM FLOW DEPTH VELOCITY SPECIFIC PRESSURE-I-
CONTROL(FT) (FT) (FT/SEC) ENERGY(FT) MOMENTUM (POUNDS)
.000 .521 3 504 .711 20 .32
.010 .514 3 569 .712 20 .33
.040 .507 3 637 .712 20 .34
.092 .500 3 707 .713 20 .38
.170 .493 3 780 .715 20 .42
.276 .486 3 855 .716 20 .48
.412 .479 3 933 .719 20 .56
.583 .472 4 013 .722 20 .64
.792 .465 4 097 .725 20 .75
1 .046 .458 4 184 .730 20 .87
1 .349 .451 4 275 .734 21 .01
1 .711 .444 4 369 .740 21 .16
2 .139 .437 4 466 .747 21 .34
2 .644 .430 4 568 .754 21 .53
3 .242 .423 4 674 .762 21 .74
3 . 951 .416 4 784 .771 21 .97
4 .794 .409 4 899 .782 22 .23
5 .805 .402 5 020 .793 22 .50
7 .029 .395 5. 145 .806 22 .80
8 . 534 .388 5. 276 .820 23 .13
10 . 424 .381 5. 413 .836 23 48
12 .875 .374 5. 557 .853 23 86
16 .215 .367 5. 707 .873 24 27
21 . 182 .360 5. 865 .894 24 71
28 .690 .354 6. 003 .914 25 10
NODE 40.00 HGL = < 44.881>;EGL= < 45.071>;FLOWLINE= < 44.360>
******************************************************************************
FLOW PROCESS FROM NODE 40.00 TO NODE 40.00 IS CODE = 8
UPSTREAM NODE 40.00 ELEVATION = 44.36 (FLOW IS AT CRITICAL DEPTH)
CALCULATE CATCH BASIN ENTRANCE LOSSES(LACFCD):
PIPE FLOW = 1.91 CFS PIPE DIAMETER = 18.00 INCHES
FLOW VELOCITY = 3.51 FEET/SEC. VELOCITY HEAD = .191 FEET
CATCH BASIN ENERGY LOSS = .2*(VELOCITY HEAD) = .2*( .191) = .038
NODE 40.00 : HGL = < 45.110>;EGL= < 45.110>;FLOWLINE= < 44.360>
******************************************************************************
UPSTREAM PIPE FLOW CONTROL DATA:
NODE NUMBER = 40-00 FLOWLINE ELEVATION = 44.36
ASSUMED UPSTREAM CONTROL HGL = 44.88 FOR DOWNSTREAM RUN ANALYSIS
END OF GRADUALLY VARIED FLOW ANALYSIS
******************************************************************************
PIPE-FLOW HYDRAULICS COMPUTER PROGRAM PACKAGE
(Reference: LACFCD,LACRD, AND OCEMA HYDRAULICS CRITERION)
(c) Copyright 1982-98 Advanced Engineering Software (aes)
Ver. 7.1 Release Date: 01/01/98 License ID 1459
Analysis prepared by:
BHA
5115 AVENIDA ENCINAS
SUITE L
CARLSBAD, CA 92008
************************** DESCRIPTION OF STUDY **************************
* HYDRAULIC GRADE LINE ANALYSIS NODES 41.1 TO 41.0 *
* *
* *
**************************************************************************
FILE NAME: 810-Pl.DAT
TIME/DATE OF STUDY: 13: 5 9/14/2002
******************************************************************************
GRADUALLY VARIED FLOW ANALYSIS FOR PIPE SYSTEM
NODAL POINT STATUS TABLE
(Note: "*" indicates nodal point data used.)
UPSTREAM RUN DOWNSTREAM RUN
NODE MODEL PRESSURE PRESSURE-t- FLOW PRESSURE-l-
NUMBER PROCESS HEAD(FT) MOMENTUM(POUNDS) DEPTH(FT) MOMENTUM(POUNDS)
41.10- 1.49* 89.37 .46 35.34
} FRICTION
41.00- 1.16* 57.49 .62 Dc 31.06
} CATCH BASIN
41.00- 1.22* 51.34 .62 Dc 11.10
MAXIMUM NUMBER OF ENERGY BALANCES USED IN EACH PROFILE = 25
NOTE: STEADY FLOW HYDRAULIC HEAD-LOSS COMPUTATIONS BASED ON THE MOST
CONSERVATIVE FORMULAE FROM THE CURRENT LACRD,LACFCD, AND OCEMA
DESIGN MANUALS.
******************************************************************************
DOWNSTREAM PIPE FLOW CONTROL DATA:
NODE NUMBER = 41.10 FLOWLINE ELEVATION = 42.69
PIPE FLOW = 2.66 CFS PIPE DIAMETER = 18.00 INCHES
ASSUMED DOWNSTREAM CONTROL HGL = 44.180
NODE 41.10 : HGL = < 44.180>;EGL= < 44.215>;FLOWLINE= < 42.690>
******************************************************************************
FLOW PROCESS FROM NODE 41.10 TO NODE 41.00 IS CODE = 1
UPSTREAM NODE 41.00 ELEVATION = 4 3.01 (FLOW IS SUBCRITICAL)
CALCULATE FRICTION LOSSES(LACFCD):
PIPE FLOW = 2.66 CFS PIPE DIAMETER = 18.00 INCHES
PIPE LENGTH = 15.76 FEET MANNING'S N = .01300
NORMAL DEPTH(FT) = .43 CRITICAL DEPTH(FT) .62
DOWNSTREAM CONTROL ASSUMED FLOWDEPTH(FT ) = 1.49
GRADUALLY VARIED FLOW PROFILE COMPUTED INFORMATION:
DISTANCE FROM FLOW DEPTH VELOCITY SPECIFIC PRESSURE-I-
CONTROL(FT) (FT) (FT/SEC) ENERGY FT) MOMENTUM (POUNDS)
.000 1.490 1.506 1. 525 89.37
1.739 1.455 1.518 1. 491 85.60
3.461 1.420 1.536 1. 457 81.90
5.170 1.385 1.559 1. 423 78.29
6.868 1.351 1.587 1. 390 74.75
8.554 1.316 1.619 1. 356 71.30
10.230 1.281 1.655 1. 323 67.95
11.894 1.246 1.695 1. 291 64.70
13.546 1.211 1.739 1. 258 61.56
15.185 1.176 1.789 1. 226 58.54
15.760 1.164 1.807 1. 215 57.49
NODE 41.00 : HGL = < 44. 174>;EGL= < 44.225>; FLOWLINE= < 4 3.010>
******************************************************************************
FLOW PROCESS FROM NODE 41.00 TO NODE 41.00 IS CODE = 8
UPSTREAM NODE 41.00 ELEVATION = 43.01 (FLOW IS SUBCRITICAL)
CALCULATE CATCH BASIN ENTRANCE LOSSES(LACFCD):
PIPE FLOW = 2.66 CFS PIPE DIAMETER =
FLOW VELOCITY = 1.81 FEET/SEC. VELOCITY HEAD =
CATCH BASIN ENERGY LOSS = .2*(VELOCITY HEAD) = .2*(
18.00 INCHES
.051 FEET
.051) = .010
NODE 41.00 : HGL 44.235>;EGL= < 44.235>;FLOWLINE= < 43.010>
******************************************************************************
UPSTREAM PIPE FLOW CONTROL DATA:
NODE NUMBER = 41.00 FLOWLINE ELEVATION = 43.01
ASSUMED UPSTREAM CONTROL HGL = 43.63 FOR DOWNSTREAM RUN ANALYSIS
END OF GRADUALLY VARIED FLOW ANALYSIS
II. CALCULATIONS
D. INLET SIZE CALCULATIONS
INLET SIZING TABLE
NODE Q
(cfs)
Street
Grade
(%)
Depth of
flow
(ft)
Inlet
Type
Length of
Inlet Opening
(ft)
Length of
Inlet Shown
on Plan (ft)
Comments
41 2.7 1.00 0.30 Type "B-r Inlet 8 10
45 2.4 Sump 0.26 Type "8-2" Inlet 4.8 6
75 5 Sump 0.32 Type "6-2" Inlet 8.3 10
References: City of San Diego Drainage Design Manual, Chart I-103.6A, Chart I-103.6C, and Chart I-103.6D, April 1984
Page 1 of 1
SAN DIEGO COUNTY
DEPARTMENT OF SPECIAL DISTRICT SERVICES
DESIGN MANUAI,
APPROVED Y, 4-/ ^ -^.'^r c U .
COMPUTATION OF EFFECTIVE SLOPE
FOR NATURAL WATERSHEDS
DATE APPENDIX X-B
IV-A. 11
RUNOFF COEFFICIENTS (RATIONAL METHOD)
DEVELOPED AREAS (URBAN)
Coefficient. C
Soil Group
Land Use A B £ D
Residential:
Single Family .40 .45 .50 @
Multi-Units .45 .50 .60 .70
Mobile Homes .45 .50 .55 .65
Rural (lots greater than 1/2 acre) .30 .35 .40 .45
Commercial
80% Impervious .70 .75 .80 .85
Industrial
90% Impervious .80 .85 .90 .95
NOTES:
(II
(2)
Soil Group maps are available at the offices of the Department of Public Works.
Where actual conditions deviate significantly from the tabulated imperviousness
values of 80% or 90%, the values given for coefficient C, may be revised by
multiplying 80% or 90% by the ratio of actual imperviousness to the tabulated
imperviousness. However, in no case shall the final coefficient be less than 0.50.
For example: Consider commercial property on D soil group.
Actual imperviousness = 50%
Tabulated imperviousness = 80%
Revised C = §0 x 0.85 = 0.53
80
IV-A-9
APPENDIX IX
Updated 4/93
- BOO
- 7^?^?
- £0O \
SOO
40D
\
SOO \
Fee/
— 4oao
—2ooo
—Zooa
£Qa/?r/OA/ •r i'.'.si-re 38S
^ - 7//77e of cof}£:e/7/na//o/7
i » Ler^gM of tva/er.ff/7ed
' D///'ere/7ce /n e/e\/a.h'an aVo/7ff
e/Z'sc/^/^e s/ope //ne (See Append/X X-B) j-
Z
Af//es
/O —
300
•20O
S —
4-
\
\
\
\
\
•/OO
•SO
•40
— JO
— za
OS —
NOTE
(FOR NATORAr^MTERSFED^
ADD TEN MINUTES TO \
\ COMPUTED TIME OF CON- \
|IC£NJiRATION- I
— /O
Fee/ //ours
4 —
\^S/}0/)
'—4^0
— 30^ \
\ _
- 2000
I—/soa
/600
• /400
I— /2oa - /ooo — 900 — 800
— 700
— 600
-SOO
I— 400
— 300
\
\
ZOO
A/I/nu/es
— Z40
/BO
/20
/OO
90
80
70
-60
- SO
40
I— 30
-ZO
/B
/6
/Z
- /O
9
8
7
6
— 4-
— 3
H
SAN DIEGO COUNTY
DEPARTMENT OF SPECIAL DISTRICT SERVICES
OESIGN MANUAL
APPROVED O < // //4r</r<^ ^^Z^^
NOMOGRAPH FOR DETERMINATfON
OF TIME OF CONCENTRATION (Tc)
FOR NATURAL WATERSHEDS
DATE APPENDIX X-A
U/eS/9A/ /?/?£/?S 0^^£^l/P^/£> T/MS OF FLOIV CU/ei/£S
Sxomp/e ••
S/yeo •• Ze/rp/A a/" F/otv • JOO //:
S/o^e ' AO '/o
CoeMb/e/}/ o/ £L//fo/f. C-.SO
^'eac/ •• Oi'ef/tfne/ F/otY//nre '/^ Af//7i//es
SAN DIEGO COUNTY
DEPARTMENT OF SPECIAL DISTRICI SERVICES
DESjGN MANUAL
APPROVED /V- -V. /y'^-' '•- 1 /T c'TlX
URBAN AREAS OVERLAND TIME
OF FLOW CURVES
DATE APPENDIX X-C
RESIDENTIAL STREET
ONE SIDE ONLY
2-I 1111!
5 6 7 8 9 10
DISCHARGE (C. F S.)
I
20
I
30
I I
40 50
EXAMPLE;
Given; Q= 10 S= 2.5%
Chart gives: Depth = 0.4, Velocity = 4.4 fp.s.
SAN DIEGO COUNTY
DEPARTMENT OF SPECIAL DISTRICT SERVICES
DESIGN MANUAL
APPROVED /b./J•/Ufj^r^^4LI^6y^
GUTTEf; AND ROADWAY
DISCHARGE-VELOCITY CHART
APPENDIX X-D
TWA 1-5
Lv./TTY OF SAN DIEGO
DEPARTMENT OF SANITATION &
FLOOD CONTROL 100-YEAR P5?ECIP!TAT!0rJ
33"
^2W^ ISOPLUVIALS
PRECiPiTATIOn \li
OF lOO-YEAR 6-HOUR
iFEfjTliS GF AN i::Cli
> I
Prepnt.-d by
U.S. DEPARTMENT OF COMMERCE
NATfO.VAL OCEANIC AND ATJOSPIIERIC AOKINISTRATION
SPECIAL STUOIES BRANCH. OFFICE OF HYDROLOGY. NATIONAL WEATHER SERVICE
30
116'
COUNTY OF SAN DIEGO
DEPARTMENT OF SANITATION 8-
FLOOD CONTROL
its
33'
30'
15'
i»5
Prcpai
U.S. DEPARTMEN
NATIONAL OCKAMC AND AT:.
SPECIAL STUDIES BKANCII, OKKICE OF Iffl
30'
lOO-YEAR 24-!I0ljR PRECIPITATION
'-20^ ISOPLUVIALS OF 100-YEAR 24-HOUR
PRECIPITATION IN EMTHS OF AN INCH
nn /i5' 30' in 117' in' 116'
INTENSriY-DURATIurt DESIGN CHART
n ~"^'riTri"l'l!''r'"'l''rin-""1iii.iiuii.i!iiiiirp:. ; ". .' i'l.iu.i li IHI nif I in
Equation: 7.44 D -.645
Intensity (In./Hr.)
6 Hr. Precipitation (In.)
Duration (Min.)
Directions for Application:
1) From precipitation maps detennine 6 hr. and
24 hr. amounts for the selected frequency.
These maps are printed in the County Hydrology
Manual (10, 50 nnd 100 yr. maps included in th
Design and Procedure Manual).
2) Adjust 6 hr. precipitation (if necessary) so
that it is within the range pf 45% to 65% of
the 24 hr. precipitation. (Not r.pplicable
to Desert)
3) Plot 6 hr. precipitation on the right side
of the chart.
4) Draw a line through the point parallel to the
plotted lines.
5) This line is the intensity-duration curve for
the location being analyzed.
Application Form:
0) Selected Frequency /c?0 yr.
1) Pfi = ^'^ In., P..= , *P
2) Adjusted *Pg=
24
24
in.
3)
4)
c
I «
min.
in/hr.
*Not Applicable to Desert Region
30 40 50 1 APPENDIX XI
IV-A-14
nni.; Or? 1 /or;
CHART 1-103.6 A
CAPACITY OF CURB OPENING INLETS
ASSUMED 2% CROWN.
Q = 0.71 (A+Y)^/^
*A
Y
= 0.33
= HEIGHT OF WATER AT CURB FACE (O.I*' MAXIMUM)
REFER TO CHART 1-104.12
L = LENGTH OF CLEAR OPENING OF INLET
*Use A=0 when the inlet is adjacent to traffic;
i.e., for a Type "J" median inlet or where the
parking lane is removed.
REV. CITY OF SAN DIEGO - OESIGN GUIDE SHT. NO.
CAPACITY OF CURB OPENING INLETS
13
CHART I-I03.6C
1.0
.t-
•-9
.7-
• - e
u
Ul
u.
.«-
.9-
5 }-5
UJ .' a. o
O
u
uj
I .3-
.2-
•12
II
10
to
o
T
- 3
7 (0 U X u z
-J
o
u. o
.2
•U3
UJ
a.
o
o
UJ
I
o
O u.
CE Ul
a.
u
<
'.5
• 4
•2
I-.2
•.I
-.06
-.05
-J34
L.X)3
t- 2
H*if HI (f curb
i j 1 -4 i -
••rfaci of
ELEVATION SECTION
I 15
-5
-4
-3
-2
(9 Z
o
u o
o
UJ
u.
o w z et
a.
a
Ul o z o a
-1.0
- .9
- .8
- .7
- .6
_ .5
1 .4
- .3
- .2
>- .15
REV. CITY OF SAN OIEGO - DESIGN GUIDE SHT. NO.
NOMOGRAM-CAPACITY ,CURB
INLET AT SAG
NOMOGRAM-CAPACITY ,CURB
INLET AT SAG
NOMOGRAM-CAPACITY ,CURB
INLET AT SAG
'{"mm." PUP
III. REFERENCES
IV. EXHIBITS
IV. EXHIBITS