Loading...
HomeMy WebLinkAboutCT 10-01; Sea Breeze Villas; Hydrology Study; 2010-08-12Hydrology Study RECORD COPY Initial Date Sea Breeze Villas Project No. CT 10-01 Carlsbad, California Prepared For: TMS Development, LLC 32 Sylvan Irvine, California 92603 Prepared By: Surender Dewan, P.E. DMS Consultants, Inc. 12371 Lewis Street, Suite 203 Garden Grove, California 92840 714.740.8840 August 12, 2010 DMS CONSIJ l/r A NTS, INC. c I V r 1. K N G 1 N E F; R S p o < SEA BREEZE VILLAS CARLSBAD Site Description The proposed project is located in tlie City of Carlsbad on the south side of Tamarack Avenue, at 391 Tamarack Avenue on a 0.70 acre site. The proposed project is a 12-unit airspace condominium project. Purpose The purpose of this study is to determine the total runoff generated for a storm of six (6) hour duration for one hundred (ICQ) year frequency and design an infiltration system to store the increase in volume of runoff between the pre and post runoff condition. For overflow conditions a 12-inch diameter PVC pipe has been installed, this overflow pipe connects to an existing catch basin located along the southerly curb of Tamarack Avenue. Section 1.0 100 Year Hydrology Calculations 1.1 Rainfall The 100 year 6 hr rainfall depth was taken from the San Diego County Hydrology Manual isopluvial maps. Figure 1 below is an enlarged copy of the applicable section of the map. 1.1.1 Existing Condition Rainfall Rainfall for the existing condition was taken from the Manual. 1.1.2 Proposed Condition Rainfall The total 100 year storm depth forthe proposed condition was calculated by subtracting the Water Quality Depth (see below) from the 100 year storm total total from the Manual. Figure 1100 Year 6hr Isopluvials 1.2 Soil Tvpe The hydrologic soil type for the area of the proposed tract is listed as "B" in the Manual Appendix A. Runoff Coefficients Runoff coefficients for the pre and post project condition were taken from Table 3-1 ofthe Hydrology Manual. (See attached table 3-1.) 1.3 Time of Concentration (Tc) 1.3.1 Existing Condition Tc The lot currently drains, via overland flow, to the northwest with an average slope of 2%. The iniital time of concentration (Ti) was estimated using Table 3-2 of the Hydrology Manual (See attached Table 3-2). CARLSBAD Figure 2 Soil Type The Tt for the rest of the flow distance was estimated Manning's equation assuming a broad open swale with a 20:1 side slope to calculate the flow velocity. See the attached hydraulic calculations for the swale travel time. 1.3.2 Proposed Condition Tc In the proposed condition the lots drain to a paver swal in the center of the tract wnich conveys the flows to the north east corner of the lot. The flows then enter a storm drain pipe and are conveyed to the existing inlet in Tamarack Avenue. The initial Ti was estimated using Table 3-2 ofthe Hydrology Manual. The velocity in the swale was estimated using Manning's equation and the velocity in the pipe was calculated using V = Q/A and assuming the pipe will be flowing full. Section 2.0 Storm Water Quality Calculations 2.1 Rainfall The storm water quality treatment J volume was taken from the Manual Appendix E. Figure 3 is an enlarged copy ofthe applicable section of the map. 2.2 Storage The required storage was calculated using the pre and post project runoff coefficients from the Manual and determining the incremental increase in the storm water yeild for the water quality depth. The size of the paver area and the depth ofthe gravel subbase were set so that the entire incremetal increase in the storm water quality runoff could be stored in the gravel subbase. (See the attached storm water quality calculations) 2.3 Infiltration The geotechnical evaluation of the site yielded a percolation rate of 15 gallons per day per square foot or 2.003 cubic feet per day per square foot. The required infiltration time was calculated by dividing the required storage by the area ofthe paver swale and the rate of percolation for the geotechnical analysis. See the attached calculations for the results of the analysis. Figure 3 Storm Water Quality Depth Qioo~ VICINITY MAP LEGEND AREA DISCRIPTION AREA IN ACRES (joT) NODE NUMBER SCALE: r=30' DMS CONSULTANTS. INC. CIVIL ENGINEERS 12371 Lewis St. #203 Garden Grove CA. 92840 P. 7U-740-8840 F. 714-740-8842 HYDROLOGY PLAN PROPOSED CONDITIONS SEABREEZE VILLAS CARLSBAD. CALIFORNIA SCALE: r=30* DMS , VICINITY MAP NP NTS' LEGEND AREA DISCRIPTION AREA IN ACRES CjoT) NODE NUMBER CONSULTANTS. INC. CIVIL ENGINEERS 12371 Levis St. #203 Garden Grow CA. 92840 P. 714-740-8840 F. 714-740-8842 HYDROLOGY PLAN EXISTING CONDITIONS SEABREEZE VILLAS CARLSBAD, CALIFORNIA Site Data Graded Area 85th Percentile Depth Soil Group Pre Project Runnoff Coefficient "C" Post Project Project Runnoff Coefficient "C" Storm Water Quality Volume Storm Water Quality CalGulations for Seabreeze Villas Pre Project 85th Percentile Runoff Volume Post Project 85th Percentile Treatment Runoff Volume Required Infiltration Volume (LID) Design for Infiltration of Treatment Volume Available Storage Paver Length Paver Width Paver Area Gravel Subbase Depth Porosity Total Storage Volume Available Time for Complete Infiltration Infiltration Area Infiltration Rate Infiltration Rate Total Infiltration Per Day Total Infiltration Per Hour Required Infiltration Time Value Units 30100 sf 0.61 in B 0.25 0.58 382.52 887.45 504.9275 887.45 285 8 2280 12 0.4 912 2280 15 2.003 4566.09 190.25 4.66 ft'^3 ft'^3 ft'^3 ft'^S ft ft ft'^2 in ff^S > 887 OK ft'^2 gal/day/square foot cubic feet /day / square foot cubic feet/ day cubic feet/hour hours < 72 Hours OK site Data Value Units Graded Area 30100 sf Soil Group B Pre Project Runnoff Coefficient "C" 0.25 Post Project Project Runnoff Coefficient "0" 0.58 Pre Proiect 100 vear 6hr Runoff Pre Project Ti 10.90 min Earth Swale Length 210.00 ft Earth Slope 0.020 percent Earth Swale Z 20.00 Earth Swale N 0.025 ft Earth Swale Flow Depth 0.210 ft Earth Swale Velocity 0.56 ft/sec Earth Swale Tt 6.24 min Tc = Ti + Tt 17.14 min 100 year 6 hr Depth 2.50 in 100 year 6 hr intensity 2.98 in/hr 100 Year flow rate 0.51 cfs Post Proiect 100 vear 6hr Runoff Post Project Ti 8.20 min Paver Swale Length 235.00 ft Paver Slope 0.005 percent Paver Swale Z 50.00 Paver Swale N 0.02 ft Paver Swale Flow Depth 0.155 ft Paver Swale Velocity 0.75 fl/sec Paver Swale Tt 5.24 min Pipe Size 12.00 in Pipe Length 275.00 ft Pipe Velocity (Assume pipe flows full) 1.04 ft/sec. Pipe Tt 4.39 min Total Tt 9.63 min Tc 17.83 min 100 year 6 hr Depth 2.50 in Infiltration Depth (See Storm Water Calculations) 0.61 in Effective 100 6hr Depth at ground surface 1.89 in 100 year 6 hr intensity 2.19 in/hr Infiltration Area 2280.00 ft'^2 Graded Area Less Infiltration Area 27820.00 ft'^2 100 Year flow rate 0.81 cfs too Year Swale Velocity Calculations for Seabreeze Villas Paver Swale I-A2/3 s s'^.5 q VbL L. 4 ,0 aroa WD f rV/.3 S o ..J M '^"""m." 0 01-5 0 50 50 1.125 15.003 0,074985 0.177821 0.0018 0.042426 0.840813 0.747389 0,15 0.015 0 50 Natural Swale ,1 T9 arpa WD r r'^2/3 s s'^.5 q VEL 021" 0 025 0 20 20 0,882 8410493 0.104869 0.222381 0.0018 0.042426 0.494631 0.560807 Paver Swale depth n b zl z2 area wp r r'^2/3 s s'^.5 q VEL 0.155 0.015 0 50 50 1.20125 15.5031 0.077485 0.181751 0.0018 0.042426 0.917643 0.763907 Natural Swale depth n b zl z2 area wp r r'^2/3 s s'^.S q VEL 0.12 0.025 0 50 50 0.72 12.0024 0.059988 0.153241 0.0018 0.042426 0.278243 0.386448 SAN DIEGO HYDROLOGY MANUAL (ATTACHMENTS) Table 3.1 and Table 3.2 San Diego County Hydrology Manual Date: June 2003 Section: Page: Table 3-1 RUNOFF COEFFICIENTS FOR URBAN AREAS 3 6 of 26 Land Use Runoff Coefficient "C" Soil Type NRCS Elements Counfy Elements % IMPER. A B C D Undisturbed Natural Terrain (Natural) Permanent Open Space 0* 0.20 0.25 Pre Project 0.35 Low Density Residential (LDR) Residential, 1.0 DU/A or less 10 0.27 0.32 0.36 0.41 Low Density Residential (LDR) Residential, 2.0 DU/A or less 20 0.34 0.38 0.42 0.46 Low Density Residential (LDR) Residential, 2.9 DU/A or less 25 0.38 0.41 0.45 0.49 Medium Density Residential (MDR) Residential, 4,3 DU/A or less 30 0.41 0.45 0.48 0.52 Medium Density Residential (MDR) Residential, 7.3 DU/A or less 40 0.48 0.51 0.54 0.57 Medium Density Residential (MDR) Residential, 10.9 DU/A or less 45 0.52 0.54 0.57 0.60 Medium Density Residential (MDR) Residential, 14.5 DU/A or less 50 0.55 0.58 Post Project 0.63 High Density Residential (HDR) Residential, 24.0 DU/A or less 65 0.66 0.67 0.69 0.71 High Density Residential (HDR) Residential, 43.0 DU/A or less 80 0.76 0.77 0.78 0.79 Commercial/Industrial (N. Com) Neighborhood Commercial 80 0.76 0.77 0.78 0.79 Commercial/Industrial (G. Com) General Commercial 85 0.80 0.80 0.81 0.82 Commercial/Industrial (O.P. Com) Office Professional/Commercial 90 0.83 0.84 0.84 0.85 Commercial/Industrial (Limited I.) Limited Industrial 90 0.83 0.84 0.84 0.85 Commercial/Industrial (General L) General Industrial 95 0.87 0.87 0.87 0.87 •The values associated with 0% impervious may be used for direct calculation of the coefficient, Cp, for the soil type), or for areas that will remain undisturbed in perpetuity. is located in Cleveland National Forest). DU/A = dwelling units per acre NRCS = National Resources Conservation Service runoff coefficient as described in Section 3.1.2 (representing the pervious runoff Justification must be given that the area will remain natural forever (e.g., the area 3-6 San Diego County Hydrology Manual Date: June 2003 Section: Page: 12 of 26 Note that the Initial Time of Concentration should be reflective ofthe general land-use at the upstream end of a drainage basin. A single lot with an area of two or less acres does not have a significant effect where the drainage basin area is 20 to 600 acres. Table 3-2 provides limits of the length (Maximum Length (LM)) of sheet flow to be used in hydrology studies. Initial Tj values based on average C values for the Land Use Element are also included. These values can be used in planning and design applications as described below. Exceptions may be approved by the "Regulating Agency" when submitted with a detailed study. Table 3-2 MAXIMUM OVERLAND FLOW LENGTH (LM) Element* DU/ Acre .5% 1% 2% 3% 5% 10% Element* DU/ Acre LM Ti LM Ti LM Ti LM Ti LM Ti LM Ti Natural 50 13.2 70 12.5 85 10.9^ -mr -toe-Ti ^re Project LDR 1 50 12.2 70 11.5 85 10.0 100 9.5 100 8.0 100 6 .4 LDR 2 50 11.3 70 10.5 85 9.2 100 8.8 100 7.4 100 5.8 LDR 2.9 50 10.7 70 10.0 85 8.8 95 8.1 100 7.0 100 5.6 MDR 4.3 50 10.2 70 9.6 80 8.1 95 7.8 100 6.7 100 5.3 MDR 7.3 50 9.2 65 8.4 80 7.4 95 7.0 100 6.0 100 4.8 MDR 10.9 50 8.7 65 7.9 80 6.9 90 6.4 100 5.7 100 4.5 MDR 14.5 50 -str -6.0--too 100 ~4 Ti Post Project HDR 24 50 6.7 65 6.1 75 5.1 90 4.9 95 4.3 100 3 .5 HDR 43 50 5.3 65 4.7 75 4.0 85 3.8 95 3.4 100 2.7 N. Com 50 5.3 60 4.5 75 4.0 85 3.8 95 3.4 100 2.7 G. Com 50 4.7 60 4.1 75 3.6 85 3.4 90 2.9 100 2.4 O.P./Com 50 4.2 60 3.7 70 3.1 80 2.9 90 2.6 100 2.2 Limited I. 50 4.2 60 3.7 70 3.1 80 2.9 90 2.6 100 2.2 General I. 50 3.7 60 3.2 70 2.7 80 2.6 90 2.3 100 1.9 *See Table 3-1 for more detailed description 3-12