Loading...
HomeMy WebLinkAbout1 LEGOLAND DR; ; CB002319; PermitL/[v City of Carlsbad 06/27/2000 Patio/Deck Permit Permit No:CB002319 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: 1 LEGO DR CBAD PATIO 2111000900 Lot#: O $11,100.00 Construction Type: NEW LEGOLAND SKY CYCLE STATION 1200 SF SHADE CANOPY LEGOLAND CALIFORNIA INC <LF> LEGOLA~D-ESTATES AG Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: ISSUED 06/19/2000 JM 06/27/2000 06/27/2000 Applicant: ___..Owner:~· LEGOLAND CALIFORNIA INC <LF> LEGOl:AND ESTA")2ES:AG!\ C/0 PROPERTY TAX SERV co / ( ~ ~QJ>R0'1E~F)TAX SERV ffl1 06/27/00 0001 01 P o Box 543185 /(y~~ p,0-a0x,5t~·~ eys;J ~ c-PRMT DALLAS TX 75354 \'::::::!) DALL.AS TX 753~~~ Total Fees: In~ ~/r1/\c-~~ <a~ $217.39 / ~if'ey~}" ~a18i1ljeDue: $132.19 r) -I • ~ ", ~/1/ ,n .~ \ FINAL APPROVAL Date: 4P~& Clearance: _____ ____ NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permitwas issued to ptote§t imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any.subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, .grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which ou have reviousl oeen iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. 2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161 02 132-19 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr •• Carlsbad CA 92009 (760) 438-1161 1, FOR OFFICE USE ONLY . PLAN CH~K NO. cli ~Z?,£1, EST. VAL, l ( l ()0 I of Bathrooms ,2. Telephone, Fax, ·3, Name Neme &. · CONTRACTOR·. COMPANY.-NAMETrt~)t:':.1 !'ti"-lr:. :!":·:.i';;..~1-·· "·:·. !Sec. 7031.5 Bu1in111 and Prof111iona Code:. Any City or County which r1quir .. a permit to c0n1tOACt, 1iter, -improve, dlmolllh a, repair eny 1tructur1, prior to its issuance, 1110 r1quirea the applicant for such permit to file a algnad atat~ent that ha ia lictnnd pursuant to tha proviaiona of the Contr1cto,'1 License Law (Chapter 9, commending with Section 7000 of Dlvillon 3 of the 8ulinlaa and ProfNilona Code) a, that ha la eul'!!Pt lharefrom, and thl bui1 for thl 1U1g1d exemption. Any violation of Section 7031.6 by.any applicant for,1 permluubjlctl the applicant to a clVil penalty of not more lhln five hundred dollars ft500ll. N1m1 Addr111 City Stell/Zip Telephone I Stet• Ucena1 I ________ _ Uc:ena1 Cius __________ _ City lualneu LICIIIII , _____ _ D11ign1r N1m1 Addtua City State/Zip Tll1phon1 State Ucenae I ________ _ ·e •.. WORKERS'.COMP&NSATION,.l:i.:,i.'.:!~-:::;,~::~:_ ..• '.' .. :: .. ~: .•. --• ,... .. .... . . .... . . .. . . . Workers' Compenaation D1clar1tion: I hereby affirm under Plll\eltY of perju,y ona of the following dlclar1tiona: O I have and will maintain I canlflcete of consent to 11lf•inaure for workers' cornpenaaJion H provided by Section 3700 of the Labor Code, for tha parf01m1nc1 of th• work for which this permit la lsauad. O I have and will maintain workers' companotlon, u required by Section 3700 of thl Labor Codi, for th1 Plrlorrnanc:e of the work for which this permit is issued. Mv worker's compensation lnsur1ni:1 cerrier and policy numbe, are: IMurance Company------------------------Policy No.___________ Expiration D1t1. ______ _ !THIS SECTION NEID NOT IE COM~ETED If THE PERMIT IS FOR ONE HUNDRED DOLLARS 1noo1 OR LESS) O CERTIFICATE OF EXEMPTION: I certify that In thl performance of the work lor which this Pll'mit la iaaued, I ahell not employ any p1r10n in any menner 10 11 to become eubj1ct to th• Work1re' Compena1tlon,L1ws of C1lif01nia. WARNING: Fallw1 to HCUfl woril1ta' campanaatlon COVIIIII la Wllawful, and 1111111 IUbjact· an employll' to Cflmlnlll ........... and clvll flnla up to -hundred thoueand dollar• It 100,000J, In ~ to tha coat of. compenaatlon, dlmegel u Pf~ fo, In Saot1on 370I of tha Labor coda, lnt1t .. 1 and enomey•a fNI. SIGNATURE.______________________________ DATE ________ _ ·1. · OWN!R-IUII.DER'D!CL'ARATION'!'i·w••:: -~\·;: ·::·, .... _. .. • ·· ... , · .. ·-· · '. I hereby affirm that I 1m exempt from the Contractor's Uc1nn Law for th• following reason: O I, as owner of tho property or my employ ... with w1g11 11 their 1011 comp1n11tlon, will do the work and the 1tructure 11 not intended or offered for Hla (Sac. 7044, BusinH1 and Profeuiona Codi: Thi Contrec:~or·a Uc1na1 i..tw doaa not 1pply to an owner of P,GP!N\Y·who !:luilds or lmprov11 thar1on, and who doH such work himHII or through.Iii• own 1mplo'Vffl,· provided that such lmprov1mant1 are no_t lntandld or ottered fa, aale. II, how1var, the building or improv1m1nt is i wlthin one y11r of c:ompl1tion, the OWMl'•bui!der wlU have the burden of proving that hi did not build or i~P,l'ove for thl pu,poae of 11111. I, 11 owner of th1 property, 1m-exc:luslvely contracting with llc:-ld contractors to c0n1truc:t the projact CSac. 7044, lualnaaa and Profuaiona Codi: Thi tr1ctor'1 Liclnae Law dou not JPIIIY to an owflll' of proPl'tV who builds or lmprovu thereon, and contrac:ts for IUCh projact1 with contractorlal lic:-lld putauant _to the Contractor'• Ucenae Law), O I am exempt under Section ______ luilnlsa arid ProfeNlons Codi ior this reason: 1; I p1raon1lly plan to provide the major labor and matorllla for conatructlon of the propoald·prop111y.lmprovemant. 0 YES ONO 2. I lh1v1 / h1v1 not) 1lgn1d an 1ppllcatlon for I! bulldlng permit fo, thl praposad work. 3. I have cont~actld with the followlng.pt1r101:1 lfirml to provide the propo11d c0n1tructlon (Include nam1 / addrua / phone number/ contrec:t911 lic11111 numbarJ: 4. I plan to provide portions of the work, ~ I have hired the following p1r1. to coordinate, supervln·1nd provide tha major work (include name/ addti11 / phone number/ contractora license numbar): ___ ..,..·_---,4-..,....-,A~-~------------------------------- 5. I will provide some of the work, but I hav1 c:ontr wirig·per1or11 to provide iha work lndlcetad lincludi nam1 / 1ddt111 / phone number / type of work): · PROPERTY OWNER SIGNATURE A,....,...,:::;.;....-y1.~.1:-..,,..~-Dl-:a-,u-Jh:..~-----I-------DATE -~~~...r...~~.!:c):::::..,_ COMPLETE.THIS.SECTION FO ' .ONL;Y,:,:.:,,.;., .. ,::· .... ;·· .--_ .. , .. , : ,, , ·. :·.1 . Is the 1pplic1nt or future building occupa r•ad to eubin!t it ' tlly hazardous matltiala ·r1glstr1tion ~~ ri1k manag1m1nt and pr1vantion progrem under Sections 25505, 2653;i 25634 .of th1°Praaley-T1Mer He11rdou1 Sub1tanc1 Account Act? 0 YES lli:r'NO Is the applicant or future building occ:up t required to obtain• permit from the alt pollutlon·control.dlatrlct or air quality m1nagem1nt diatrict7 0 YES ~ Is the facility to be constructed within 1,000 f11t of the outer boundary of a school aite7 D YES g<o IF ANY OF THE ANSWERS ARE YES, A ANAL CE!ITlflCATE OF OCCUPANCY MAY NOT IE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8, ... ,.CONSTRUCTIQN LENDING~GEN~ltt~~:ffiJ·~,;;;;.\'..:J,;J;:,'.Yt.:·;., .. _.,:_',f: ' .'· ,;:: , .. · .'· .:._ .. ,. .• -.:·. .. .. ·-·-:: .. · ... I horeby affirm that there ia a construction lendlng,agani:y for the p1rform1nc1 of th1 work for.which this permit la i11ued (Sac. 30971il Civil Codel. LENDER'S NAME--------------,.-LENDER'S ADDRESS ______________________ _ ·9. APPLICANT CERTIRCATION,r:,_i:/, ,_l';;:;:1::·.:.:·;(; ;,d.0/:;-:'.:. _·,,_-:•····,: :; ... ' •• .... •• • I cartify that I have read the 1pplic1tion and state-that the.above Information Ii correct.and that the Information on the plans la accurate. I agrH to comply with 111 City ordin1ncea and State 11w1 relating to building conatruction. I hareby authorize repr111ntatlv11 of the Cltt of Carlabad to enter upon tho above m1nt1on•d property tor Inspection purp0H1. I ALSO AGREE_ TO SAVE, INl>EMNIFY ANO KEEP HARMLESS THE CITY Of CARLSIAO AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUEAOAINIT IAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is r1quirad for excav1tlona ovar 5•0• dNP and d1molltlon or construction of 1truc:tur11 over 3 1torl11 In height. EXPIRATION: Every permit l11u1d by the ~llllldlng Off I th1 provlalona of this Codi 111111 expire by·llmltatlon and b1com1 null and void If th• building or work authorized by euch permit la not °'1min · _ f IUCh permit or If the building or work authorized by auch permit 11 auapendod or 1bendoned at any tim1 a~?• wor period or 180 dava Ion 108.4,4 Uniform Building Codi). ~ / _ / APPLICANr·ss,aNATUR~---.....,.~·--4 .,;;.____ oATE G//?/ol:> L ,. City of Carlsbad Bldg Inspection Request For: 8/31/2000 Permit# CB002319 Inspector Assi~nrnent: TP --,--- Title: LEGOLAND SKY CYCLE STATION Description: 1200 SF SHADE CANOPY Type:PATIO Sub Type: Phone; 7605354307 Job Address: 1 LEGO DR Suite: Lot O -/7 Location: Inspector: ~ APPLICANT LEGOLANb CALIFORNIA INC <LF> LEGOLAND ESTArES AG Owner: LEGOLAND CALIFORNIA INC <LF> LEGOt.AND ESTATES AG Remarks: Total Time: CD Description 19 Final Structural Associated PCRs Inspection Histocy Date Description 7/21/2000 11 Ftg/Foundation/Piers 7/21/2000 12 Steel/Bond Beam 7/21/2000 72Awning Act Comments Requested By: CHRIS ROMERO Entered By: ROBIN Al!_ _____________ --'-- Act lnsp Comments CO TP (2) CAISSONS TO SHALLOW CO Ti=> WC TP r AUG-~3-00 09:09 FRfM-. r-.so P.02/02 F•097 -, Repo4No.. Ldcdon: MTWTFSS a V.,."Rlhlf: LEIGHTON AND ASSOCIATES, INC. DAILY FIELD REPORT I e·sGU Corporati.on 'l.n ~artnersliip witli (jovernment for '.Buifaing Safetg DATE: June 23,. 2000 JURISDICTION: Carlsbad PLAN CHECK NO.: 00-2319 PROJECT ADDRESS: 1 Lego Dr. PROJECT NAME: Shade Structure SET:I Sky Cycle -Stat.on Area [:8J The plans transmitted herewith have been corrected where .necessary and substantially comply with the jurisdiction's building codes. D The plans tra.nsmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are reso!ved and checked by building .department staff. D The plans transmitted herewith have significant deficiencies identified-on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check _listtransmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. . . . D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. · D The applicant's copy ofthe check list has been sent to: [:8J Esgil Corporation staff did not advise the .applicant that the plc;1n check has been completed. D Esgil Corporation staff did advise the applicant that the .plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax#: Mail Telephone Fax In Person [:8J REMARKS: Special inspection will be required for the caissons and field welding. By: Kurt Culver Esgil Corporation 0GA 0MB 0EJ 0PC 6/20/00 Enclosures: trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-}46~ + Fax (858) 560-1576_ ~ . ·' Carlsbad 00-2319 June 23, 2000 VALUATION AND-PLAN CHECK FEE JURISDICTION: Cadsbad PREPARED BY: Kurt Culver BUILDING ADDRESS: 1 Lego Dr. BUILDING OCCUPANCY: A4 BUILDING BUILDING AREA PORTION (Sq.Ft.) Shade Canopy 1000 -. .. Air Conditioning Fire Sprinklers TOTAL VALUE PLAN CHECK NO.: 00-2319 . DATE: June 23, 2000 TYPE OF CONSTRUCTION: V-N VALUATION · 1 VALUE' ($) I MULTIPl,.IER 9.25 9,250 - -- . . .. 9,250 D 199 UBCBuilding Permit Fee [g] Bldg. Permit Fee by ordinance:$ 113.58 . ' ' D 199 UBC Plan Check Fee · ~ Plan Check Fee by ordinance.: $ 73.82 Type of Review: ~ Complete Review D Structural Only D Hourly D Repetitive Fee Applicable 0. Other: Esgil Plan Review Fee: Comments: $ 59.06 Sheet 1 of 1 macvalue.doc 5100 AUG-02-00 17:16 FROM- ;• CASTECH CONSULTlNG-ENGINJmRS 445S TORRANCE aLVD •• #414 TOBR.ANCB..CA.,90503 PHONB: {310} 214-3994 , STRUC'l'URAL CALCULAUONS FOR. T-.449 P.02/04 F-092 LEGO LAND BNOJNBBRlNG FlBLir SUPPORT SHADE CONCBPTS1 INC. JOB NO. 00125 .... -· AUG-02•00 17:16 T-«9 P.03/0.( F-092 . . .. CASTECH COM;;ULTJNG ENGJNEERS ~ TORRANQE BLVD.,#414 TORRANCE.M.s 90503 !NGINEE~: 0.J.CASTAN PROJECT NO. D0125 PROJECT, I.EGO LAND ENGR-FIELD~UPPORT , DATE~ 07/19JDO V ec.'Nc.lLE:T~ ~~"11-1 z:ss oe. pr;.o ft.&.Po~ '#' oo 8S f' ...,,.._ ) . C ;;;: ~OoD p-sr,. v.J/J-.S fJ St$: 0 -:;;# 'Tf-'t ~ d/r{..C. I S' • t . -t c. = Z. t!JC(J f S .r.. I'\ :· IZ ooo ., """"' __ ........ ___ -=. • 3 9 2.. ~ . • SS'.>< ~O<ro )(/ 8 Po o r,:,r::NG,. t> c:PTH PAGE:1' P eR {J.:E:::PoR, r * oo ss J poQ ~(i. ~-b Po fl n ! (),1-6 '' ¢ x 6' oee-P · p eR Ca N $ ~ sJrn:·o N t,,J;;r;'.T7-I J"0 HAI "Pl£. L A:#Jt:.-1:S ) r-0 0 i::r::,,.r, fou 4<..E]:) T.S 1, 3 , ¢ --,::. 4 1-6 ,, D eef' T,HS ,-..,.o 05i£-,l:f 6 t C.h'f..C;) 1;,JJ;-77:tYJ/$ 1 ~ •t=eR.b A-4,/-a. '1 Dt:fJ/i .t!roa~G-I.. H,ow~\/eR ~R... TI"LJ:S ~ .:J: CM A#ff.t:r,?> ~T TO O' I l)~ e;.-p , TH A:T rs B&c.A-tJs.e nte CA <Au t,AT"I::OMS Po R. -rt-'I E M. <> 1>et-s w e-As s~t100 Res T ~ s-n F°<H~r.r:NG-J C T"l:"e-D ~ St,.A,1,Ss) • ,H;;r;S -:::S J.JoT A fl.,&rs--r/lt4 r:r-Jtal ?=00 ,r:N(S..; ' H&Nc.e :t:T Hl:rrr:, 'Tt) ie-~ ft& -C:)MP\JTE-n urr..Me..,. ,,_,~ I+ p P~ P~TIS _ ~ u ~ 1'J ) tfG-/Jc:& ~S'l'JG,,, U S A ,... .... -. , --rt -"' 'l"\ d-D-r-U f'J:: .(" 1 AUG-02-00 17:16 .. ·-· . T-«9 P.04/04 F-092 · TH~ . £.OA DS TO $:Ci! THJ:'S Ft::>'-o~tw&. wE;-:!e" FcR. A MC>-1>4U., *') v,JM,:t:-.S ~ /4 ')O)t''4C !TA.le:t"UH .. 7"H;z:.f f'AAT.t:Cut..-M .Sl'2uCTtil2-e: . ;t$ :;1.-6: f )(40 r 0... :: • U?x. 3:36€ = fJ. 11,* ' l,,t V = S"3:l "J( •64"\J. = 468- . -~ M1o: .. 86?" o.396& = 5s-43'111 f e.:; 5.S-43'7.,12.,Q -= 4i,;1."' A = Z,'J..ql<4~a -=-i-ooZ 9'~)( 3.GJ . d : .{-~~(1-t :,tt= def( .::: I•? d~ 4 .. B1 "=-S' 4.3$ ~/0 . a •••-+l J,64Z ( aa "'r ,.rr~ 4'! • -f ~ ~-~ .. ~ P$= ~J·E~ • pa(e. OF ro-Q.Tr,../G MtJSr /JS : d~s~ ., i..t' fe> oil. ~ ·'l , ¢ x s;, bst;{P A i,ll!#l"f aP 4 f • t; ._. , ,A ~a'Z"t:.~ lls.Pt:alR' v,,t~ 8 E /!tlf14t.1tf/8() P'LANNIN.G/ENCINEERINC .APPROVALS PERMIT NUMBER ==CB::;.._::2;..:,.J...,../_°!..______,._....,......_,_ bATE b ~ 23-ct) ADDRESS _1_· L£Go (}tf,IL/£ RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR ( < $10,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFlt:E BUILDING OTHER Sh01.de -S--fo.Jc:fvre -Gr-Sky Cy ck _S~ficn c/mq PLANNER ~. 7k . DATE .-G2J-00 ENGINEER -----------DATE ___ --~----- ooes/Mlsforms/Plannlng Engineering AJ>provals Carlsbad Fire. DeP,artment 002319 1635 Fars3day Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Requirements Category: · .Building Piao Reviewed by: Date of Report: 06/28/2000 ------.....------'---'-----,,-- Name: JIM FEND Address: 1 LEGO DR City, State: CARLSBAD CA 92008 Plan Checker: Job#: 002319 ------- Job Name: Legoland California Bldg#: CB002319 --------------------------..,......- Job Address: 1 Lego Dr Ste; or Bldg. No. IZI Approved · D Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approved. The approval i~ based on plans, information and / or specifications provided in your .submittal; therefore any changes to these items after this date,, includin9 field modifications, must be reviewed by this office to insure continued conformance with applicable .codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or instaH improvements. The .item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments ·atti:iched, as failure to comply with instructio't1s in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and I or ~pecifications required to indicate compliance with applicable codes ahd standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable 'codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/ or specifications to this office for review and approval. 1st 002319 2nd FD File# 3rd Other Agency ID • • • CASTECH CONSULTING ENGINEERS 4455 TORRANCE BLVD,, #41-4 TORRANCE,CA.,90503 PHONE: (310) 214-3994 STRUCTURAL CALCULATIONS FOR LEGO LAND MO:OEt # 6 CANOPY SHADE CONCEPTS, INC. JOB NO. Ob85 I i '\ I ~ • ~ V ~-, "' . M. 0 . D.·• . E . L #6 i f • .. TABLE OF CONTENTS: '1ODEL 6 ~ 80 MPH DESIGNS GENERAL DIAGRAM ----------. -----------· -··---------_ ----------------------· · -----------------------------------1 WIND I CABLE I MEMBER LOADS ------------------.,.--------------------····------.,.-------------------------2-5. FINITE ELEMENT MODEL D..il6'JRAM --"'------.,-----------------------··----·--------·---------------------------6 LOAD FILE -------------------------··. -... ------------------.----------------··--------------------------------7 8 FT. MODEL -----,-----·--'------· .--: •• ·.'.: 0 --. --------------. -----------------------------8-11 EMENT AN AL YSIS ___ ;_ ________________________________________________________________ 12-22 -COL MN BUCKLING----------,-----------------------------··-----··----------··-·---------------23 -F TING DEPTH I FLEXURE -'"--"'-------------,,-----------------------::-::---------------------------24 . ··-· .. ---~. . -ASE PLATE W / ANCHOR B,Pt-T~-:-----------.,·:~:~--------"' _____ :_ ___ ::;:··------.C.-----· -:-~~---·· 25-26 / 10 Fr. MODEL . . -- . -BULK DAT A---------.----------------------------------. ----.. -----····----------------... -----------27-30 .. :.· ,. -FINITE ELEMENT AN Ab YSI~,------.:.;., .. ,.,.----------,-~----··--------::::-:----· ·----------····------··-:;;-=-------3 ! -4:? r • • • ---• •. • --'~-· . . ~"' ~ - -COLUMN BUCKLING--... ,.,:... - -.. ------------··------------· .. · · ·---------4?. ··:·.) -FOOTING DEPTH I FLEXURE ,..,..... _ -~~_-_:::·~-----------------------.,-··------· .. -----· 1t) -..... . -BASE PLATE WI ANCHOR--:i30Ll;S --.----z:,-,.~ ..... ---··---------------.. ---------··-45-4'5-. .... ~ --· -- 12FT. MODEL -BULK DAT ---'--------------------,-----------------------------------47-50 EMENT ANALYSIS-.,...--.---------------=---·· 51-61 -cot\J ·N Buct~~.:..:t..,,__.;·:---·-_._.· __ ._. ---,..--·-··--~·-: . .-_:, ..... :_, ··-· ---··-~---·---· .:·-~· -n1 ______ _; __ _;_:. 62 :::,.. . . : .. . -For NG DEF"tif ttmffiXURE · · ------· ----· -·-· 2.· ·--· __ . -----~·-. '.:... ·---··-·---··----. ----· 63 •I' • •• ·-·· .f. :._ -B. ~E-PLAT}.W/ ANCHO~~TS ---..,--~----~.:---------------· ~----------------------~~---~?~;5 110 M,rH DE8IGNS:.,_ ··: GENE DIA GRAM.::.: ________ . ---------------------· · :·· ----. . .. ---. -..... --------------------------66 . . WIND 7 CABLE/ MEMBER LOADS ------------·----·--·~-,:--.. --~!.·, __ ..: .. _.: .. .:. .. .: ___ :_ _________________ -------·------67--70. ... • ' -.,,. ' • ,.. > • .. • • • • --• .• ____ __,.,___. .. --------------------------... --·--------------------·---·------------··--· ---· ·-71 , . . SFT. MODEL -BULK DAT A ------------------· ----------------------------· -----------------------------------------72-7 5 -FINITE ELEMENT ANALYSIS ----'-~-----------~-------------------------------------------------76-86 -COLUMN BUCKLING----·----------------·------------------.----------------------------------------------87 -FOOTING DEPTH I FLEXURE ----------------------------------------------·------------------------------88 10 FT. MODEL -BULK DAT A --------------------------------· · -----------· · -----------------------------------------------89-92 -FINITE ELEMENT ANALYSIS---------------·-----------------·----------------------------------93-103 -COLUMN BUCKLING-----------------·--------------:--.. ----------------------------------------------104 -FOOTING DEPTH/ FLEXURE---"'-----------:------'"---~-----'"-------------------------------------105 12 FT. MODEL -BULK DAT A --·------------------------------·------------------·---106-109 -FINITE ELEMENT ANALYSIS------------------------------------------110-120 -COLUMN BUCKLING----------------------------------------------·---·-----------------------------121 -FOOTING DEPTH I FLEXURE-------------------------------- GENERAL ---------------------------122 -ROOF BEAMS I COLUMN CONNECTIONS-----------------------------------------------123 -DESIGN DIAGRAMS I DETAILS --------------------------------·-----------------A-E , > T Ht==16' 8' 1 6' J_ ~ (W) 30' -B. 1 BT .............. HT .............. --...;...-- I< B 2 ~ I . I . / I )- .,:.,-..,,.. ~ MODEL # 6 GENERAL DESCRIPTION ( TRIS -AREAS ) .1 1 D1 D2 40' , . CASTE CH CONSUL TING c=NG,NE::.RS 4455 TORRANCE BLVD.,# 414 TORRANCE.CA., 90503 ENGINEER: D.J.CASTAN PROJECTNAME:MODEL#6 REPORT NO : 9773 DA TE: 07-/11197 PAGE :2 AWNING WIND LOADS.PER U.B.C.94 Ce = 1.06 ,. Ks =.60 Cqy = 1.2 (SHADE FACTOR) Cqh = 1.3 Cqu = .7 I = 1.0 Qs = l 6.4-lbf 80 MPH ft2 WIND Pv = Ks·Ce·Cqv·Qs·I Ph =Ks-Ce-Cqh·Qs·I Pv = 12.516.'bf ft2 Pu =Ks·Cqu·Ce-Qs Ph= i3.56 • lbf ft2 Pu= 7.301 • 1bf ft2 ANALYSIS OF CABLE ON LONG SIDE : THE CABLE ASSUMES A PAROBOLIC SHAPE,HENCE: Sl =40,ft W -30,ft Y(x) =A-x2 f·=l.5-ft A =-f__ . A =0.004•£1:-1 /s1 )2 . \ 2 Z:=~ 2 Zl =0·ft ,•z An =2-I Y(x) dx An =20•ft2 Ao =Sl·f-An Ao =40-ft2 w H=- 2 Jz1 FV =Pv·AT Lr = 8,ft AT·= .S·H·(Sl + Lr)-Ao AT =320•ft2 FV =4005.274•lbf h =4.5,ft CABLE LIES IN PLANE OF CANVAS.HENCE CAN ONLY TAKE PLANAR COMPONENT OF VERTICAL LOAD. . /h \ T ·=atan/-1 \H T = 16.699 •deg N -= FV,sin(T) N = 143.863 •lbf 8 . N R = -R = 71.932 •lbf DI = 16-ft D2 =8-ft Q=--N __ 2-.5-Dl -r-D2 2 D2 LC =Dl-- 2 LCl = 9.333•ft LC =20-ft D2 DI LC2 =-. LC3 =DI LCl =-;-LC2 2 T 3 M =R-LC-.5·Q·LC3·LC1 -Q· LC M =943.104•lbfft 2 M fa = 1.5.ft H =-H =628.736•lbf fa ' . ENGINEER: D.J.CASTAN PROJECT : MODEL # 6 CABLE-LONG SIDE (CONT'D) : CASTE CH CONSUL TING ENGiNEERS 4455 TORRANCE BLVD .. # 414 TORRANCE.CA., 90503 REPORT N0.9773. DATE :07/11/97 , , Ta : ·. H--R-Ta = 632.838 •lbf (TENSION IN CABLE) 1/4" DIA. CABLE HAS THE FOLLOWING TENSION ALL:OWABLES : PAGE 3 , ~ . Aoo Aoo ::.0375-in-Aff ::.15·in'" TAff =28400-lbf "Foo =-· -·TAff Too =7100•lbf Ta = 632.838 •lbf < Too= 7100•lbf CABLE ON SHORT SIDE : SSI = 30-ft fs = l.5.ft · fs AS=-- /SS l \ 2 . ' \ 2 ; . •ZSI . Aff O.K AS =0.007•ft-1 ZS =0·ft ZSI SSI 2 YS(x) =AS-x2 ASn = 2-YS( x) dx ASn = 15•ft2 H =DI h =4.5-ft •ZS ASo .=SSHs-ASn /h TS =atan:-, . \_H/ ASo =30-ft2 HS =DI ATS =.5-SSI·HS-ASo ATS =2I0•ft2 NS = FVS·sin(TS) NS =88.956•lbf 8 QS = RS .25-SSl QS =5.93•lbf ft LS = SSI 6 RS =NS 2 LS= 5•ft TS= I5.709•deg FVS =Pv-ATS RS = 44.478 •!bf SSI . M =RS·--.25-SSI·QS-I,,S M =444.778•lbf'ft fs.=l.S·ft M HS=- fs 2 HS =296.518•lbf TSS =~HS2 + RS2 TSS =299.836•lbf 1/4" DIA. CABLE 0.K. TRIBUTARY AREAS ON VARIOUS COMPONENTS: L =40-ft W = 30-ft Atot =L·W-2-Ao-2-ASo Atot = I 060• fr2 Vtot :: Pv· Atot Vtot = 13267.469•lbf (TOTAL VERTICAL LOAD) \ . ENGINEER :D.J.CASTAN PROJECT: MODEL# 6 TRIS. AREAS (CONT'D) : 1) RIDGE BEAM WTRlB W 2 Yr =Wv-LR 2) HIP BE.AMS : CASiECh CONSUL Ti NG ENGINEERS 4455 TORRANCE BLVD. #414 TORRANCE. CA. 9050~ REPORT NO. 9773 DATE: 07/11/97 Wv =Pv·WTRIB Wv=l5.646•lbf 12-~ in ft Vr = l50l.978•lbf Bl =.5-W B2 = B 1-.5 Ht = 16-ft I3T =·B1 AH= 120•ft2 HT =Ht 2 AH = .5-(BI -· B2)·Ht-.S·BT-HT PHIP =Pv·AH PHIP= I501.978•1bf PAGE: 4 LR =96-in 3) CABLE-LONG SIDE,TRAPEZOID PORTION OF HIP(NO TRAPEZOID IN THIS CASE): L =2-Dl -D2 ACl = .S·B2-(L+ D2)-Ao AC1 =140•t\2 PCI .=Pv·ACI PCI =l752.307~lbf 4) CABLE-TRIANGULAR PORTION OF.HIP: AC2 .= .5·(2·Bl)·HT ~ ASo AC2 =9()oft2 PC2 ·=Pv·AC2 PC2 = 1126.483•lbf 5) LOAD BALANCE CHECK : Ptot = Vr 1-4-PHIP + 2-PCI + 2-PC2 Ptot = 13267.469 •lbf = Vtot = 13267.469 •lbf O.K. ROOF ELEMENT ANALYSIS WILL ·BE PERFORMED,USING AN MSC/PAL2 FINITE ELEMENT MODEL.THE COMPUTER FILES WILL BE AS SHOWN BELOW. ~ MD7.TXT = BULK DATA DECK MD7L.TI<T = LOAD FILE MATERIAL ALLOWABLES FOR RO KSI STEEL FY = 50000.0·psi FB = 1.33· .66· FY FB =43890•psi ' . ENGINEER: D.J.CASTAN PROJECT: MODEL# 6 CASTc:CH CONSUL TING ENGINEERS 4455 TORRANCE BLVD.,# 414 TORRANCE.CA .. 90503 PROJECT NO. 9773 DA TE: 07 /11 /97 HORIZONTAL LOAD ON HIPS - Y -DIRECTION: HW =4.5-ft HW HB =- 2 HB = 2.25•·ft ATOT .:.S·W.(HW-HB)-ASo·tan(TS) ATOT=25.313•ft2 Pv = Ph·ATOT • 2 Py= 171.613 •lbf PAGE:5 LOAD FROM CABLE TO COLUMN : AC =.5·W·HB-ASo·tan(TS) AC =25.313•ft2 Pye = Ph·AC 2 Pye =.17l.613•lbf HORIZONTAL LOAD - X -DIRECTION : ATT = .5·(L ..-D2)-HW -.5·HB·(L..,.. D2.) -Ao-tan(T) ATT =42•ft2 Px =Ph·ATT Phips .-Px 4 Px = 569.5 •!bf Phips = 142.375 •!bf LOAD FROM CABLE TO COLUMN : ACC = .5· HB· ( L -r 02) -Ao· tan( T) ACC = 42•ft2 Pxe =Ph-ACC 2 Px:e = 284.75 •lbf Pr. -2-Phips Pr=284.75 •lbf \ . t • TYPE MD6L. TXT = So H PH DISP 1 ALL 0.0,64,65,66,67 1RCES 11 rZ -150.2 , 43 THROUGH 51, STEP 1 FZ -150.2 , 2 THROUGH 10 , STEP 1 FZ -150.2 , 16 THROUGH 24 , STEP 1 FZ -150.2 , 25 rHROUGH 33 , STEP 1 FZ -150.2 , 34 THROUGH 44 ,STEP 1 FORCES 1 FZ -225.30 , 11,15 FZ -1514.5 ,1,12,13,14 FORCES 11 FX -14.2 ,2 THROUGH 10 , STEP 1 FX -14.2 ,34 THROUGH 42 ,STEP 1 FX -28.5 ,43 THROUGH 51 ,STEP 1 FORCES 1 FX -21.4 , 11,15 FX -589.10 ,1,14 FX 297.,12,13 FORCES 1 FY 629,13,14 FY -629,12,1 "''1LVE JRCES 1 FZ 3317.0,1,12,13,14 FX -589.10,1,14 FX 297.0 ,12,13 FY -629.0,1,12 FY 629.0,13,14 FORCES 11 FX -14.2 FX -14.2 FX -28.5 FORCES 1 -2 THROUGH 34 THROUGH 43 THROUGH FX -21.4,11,15 SOLVE C:\PAL2> 10 42 51 STEP 1 STEP 1 STEP 1 I _J \. MD 6' A .1)(.T TITLE MODEL# 6 ,l0FT. COLUMN, 80MPH WIND NODAL POINT LOCATIONS 1 180. 240. o.o 2 162. 220.8 5.4 3 144. 201.6 10.8 4 126. 182.3999 16.2 5 108. 163.1999 21.6 6 90. 144-27. 7 71.99999 124.7999 32.4 8 53.99999 105.5999 37.8 9 35.99998 86.39998 43.2 10 17.99998 67.19998 48.6 11 o.o 48. 54. 12 -180. 240. -0.0 13 -180. -240. o.o 14 180. -240. o.o 15 o.o -48; 54. 16 -162. 220.8 5.4 17 -144. 201.6 10.8 18 -126. 182 ."3999 16. 2 19 -108. 163.i999 21.6 20 -90. 144 ~ 27. 21 -71.9999 124.7999 32.4 22 -53.9999 105.5999 37.8 23 -35.9999 86.39998 43.2 24 -17.9999 67.19998 48.6 25 -162. -220.8 5.4 26 -144. -201.6 10.8 27 -126. -182.399 16.2 28 -108. -163.199 21~6 29 -90. -144. 27. 30 -71.9999 -124.799 32.4 31 -53.9999 -105.599 37.8 32 -35.9999 -86.3999 43.2 33 -17.9999 -67.1999 48.6 34 162. -220.0 5.4 35 144. -201.6 10.8 36 126. -182.399 16.2 37 108. -163.199· 21.6 38 90. -144. 27. 39 71.99999 -124.799 32.4 40 53.99999 -105.599 37.8 41 35.99998 -86.3999 43.2 42 17.99998 -67.1999 48.6 43 o.o 38.4 54. 44 o.o 28.79999 54. 45 o.o 19.19999 54. 46 o.o 9.599999 54. 47 o.o o.o 54. 48 o.o -9.6 54. 49 o.o -19.2 54. 50 o.o -28.8 54. 51 o.o -38.4 54. 52 o.o 124. 32.4 53 -72. 0.0 32.4 54 o.o -124. 32.4 55 72. o.o 32.4 56 180. 240. -36. 57 -180. 240. -36. \ . 58 -180. -240. -36. 59 180. -240. -36. 60 162. 220.8 -12.6000 61 -162. 220.8 -12.6000 62 -162. -220.a -12.6000 63 162. -220.8 -12.6000 64 180. 240. -120. 65 -180. 240. -120. 66 -180. -240. -120. 67 180. -240. -120. --BLANK LINE-- MATERIAL 2.900E7 1.090E7 0.284 C C C ROOF 2.875 11 DIA. X 12 GA. BEAM 3 2.875 CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT ,..ONNECT )NNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT CONNECT NNECT .... JNNECT CONNECT CONNECT CONNECT 1 TO 2 TO 3 TO 4 TO 5 TO 6 TO 7 TO 8 TO 9 TO 10 TO 12 TO 16 TO 17 TO 18 TO 19 TO 20 TO 21 TO 22 TO 23 TO 24 TO 13 TO 25 TO 26 TO 27 TO 28 TO 29 TO 30 TO -31 TO 32 TO 33 TO 14 TO 34 TO 35 TO 36 TO 37 TO 38 TO 39 TO 40 TO 41 TO 42 TO 11 TO 43 TO 44 TO 45 TO 2.657 2 3 ,ANAL 4 ,ANAL 5 6 7 8 ,ANAL 9 10 11 ,ANAL 16 17 ,ANAL 18 ,ANAL 19 20 21 ,ANAL 22 23 24 11 ,ANAL 25 26 ,ANAL 27 ,ANAL 28 29 30 ,ANAL 31 32 33 15 ,AN~ 34 35 ,ANAL 36 ,AN~L 37 38 39· ,ANAL 40 41 42 15 ,ANAL 43 ,ANAL 44 45 46 ·O. 33 43890. -o.o o.o l • CONNECT 46 TO 47 CONNECT 47 TO 48 2.Cf CONNECT 48 TO 49 CONNECT 49 TO 50 ~ONNECT 50 TO 51 ~ONNECT 51 TO 15 ,ANAL C· C HIP BRACES C REL V,W CONNECT 7 TO 52 ,ANAL REL V,W CONNECT 21 TO 52 REL V,W CONNECT 21 TO 53 REL V,W CONNECT 30 TO 53 REL V,W CONNECT 30 TO 54 REL V,W CONNECT 39 TO 54 REL V,W CONNECT 7 TO 55 REL V,W CONNECT 39 TO 55 C C KICK BRACES C REL V,W ~ONNECT 56 TO 60 EL V,W CONNECT 3 TO 60 REL V,W CONNECT 57 TO 61 ,ANAL REL V,W CONNECT 17 TO 61 REL V,W CONNEC_T 58 TO 62 ,ANAL. REL V,W CONNECT 26 TO 62 REL V,W CONNECT 59 TO 63 REL V,W CONNECT 35 TO 63. C C CABLES 3/8" DIA. C BEAM 1 .0650 .00001 .00001 .00001 CONNECT 1 TO 12,ANAL CONNECT 12 TO 13 ,ANAL CONNECT 13 TO 14 CONNECT 14 TO 1 C C COLUMNS 4.5" DIA. X 7 GA. C 'AM 3 4.5 4.14 .... .JNNECT 1 TO 56 ,ANAL CONNECT -56 TO 64 ,ANAL CONNECT 12 TO 57 ,ANAL CONNECT 57 TO 65 ,ANAL '. CONNECT 13 TO 58 ,ANAL 30 CONNECT 58 TO 66 ,ANAL CONNECT 14 TO 59 ,ANAL CONNECT 59 TO 67 ,ANAL ND DEFINITION C:\PAL2> l • .2,i 78 BEAM FORCE RESULTS ( NODE 59 ) ( NODE 67 ELEMENT AXIAL TORSION 3.366E+03 V SHEAR -7.834E+Ol V MOMENT 8.782E+02 W SHEAR 3.273E+02 W MOMENT 5.902E+03 V MOMENT 3.340E+04 2.068E+03 W MOMENT -4.512E+03 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 78 l.454E+04 -l.179E+04 7.273E+03 l.454E+04 33.1 67 59 67 07-12-97 13:30 MSC/pai.2 Page 1 MODEL# 6 ,lOFT. COLt.JMN, 80MPH WIND -f)o v,11'/ w-r,t-JD STATIC ANALYSIS SUBCASE NO. 1 EXTERNAL FORCES NODE DIR VALUE NODE DIR VALUE NODE DIR VALUE 64 X T -2.450E+02 64 'l T -5.571E+02 64 Z T 3.268E+03 64 X R 2.782E+04 64 y R 5.951E+03 64 Z R 6.249E+02 65 X T 8.145E+02 65 'l T -6.060E+02 65 Z T 3.366E+03 65 X R 3.020E+04 65 y R 5.639E+04 65 Z R 4.022E+02 66 X T 8.145E+02 66 y T 6.060E+02 66 Z T 3.366E+03 66 X R -3.020E+04 66 y R 5.639E+04 66 Z R -4.023E+02 67 X T -2.450E+02 '67 'l T 5.571E+02 67 Z T 3.268E+03 67 X R -2.782E+04 67 y R 5.951E+03 67 Z R -6.250E+02 07-12-97 13:30 MSC/pal 2 Page 2 STATIC ANALYSIS SUBCASE NO. 1 ELEMENT RECOVERY ELEMENT 2 BEAM FORCE RESULTS ( NODE 2 ) ( NODE 3 ) AXIAL -3.125E+03 V SHEAR -1.73QE+Ol V MOMEN'r 2.486E+03 V MOMENT 1.648E+04 TORSION -7.659E+02.W SHEAR 5.210E+02 W MOMENT -4.551E+02 W MOMENT -9.200E+02 MAXIMUM STRE$SES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 2 2.283E+04 -2.943E+04 l.472E+04 2.944E+04 67.1 3 2 3 ELEMENT 3 BEAM FORCE RESULTS ( NODE 3 ) { NODE 4 ) AXIAL -5.040E+03 V SHEAR -6.932E+OO V MOMENT l.648E+04 V MOMENT 4.410E+03 TORSION -l.012E+03 W SHEAR -4.494E+04 W MOMENT -7.777E+02 W MOMENT -9.640E+02 MAXIMUM STRESSES FOR BEA!'f VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 3 2.083E+04 -3.146E+04 1.574E+04 3.147E+04 71.7 3 3 4 ~LEMENT 7 BEAM FORCE RESULTS ( NODE 7 ) ( NODE 8 ) AXIAL -3.957E+03 V SHEAR -7.248E+OO V MOMENT -8.077E+03 V MOMENT -9.647E+03 TORSION -7.326E+02 W SHEAR -5.842E+Ol W MOMENT 2.035E+02 W MOMENT 8.765E+OO ' . 32. MAXIMUM STRESSES FOR BEAM . VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 7 1.114E+04 -1.948E+04 9.749E+03 1.949E+04 44.4 8 7 8 ELEMENT 10 BEAM FORCE RESULTS ( NODE 10 ) · ( NODE 11 ) 9.677E+03 1. 094E+03 AXIAL -3.895E+03 V SHEAR 2!383E+Ol V MOMENT -7.696E+02 V MOMENT TORSION -7.326E+02 W SHEAR 3.888E+02 W MOMENT 4.540E+02 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STR~SS % YIELD @NODE CONNECTIVITY 10 1.125E+04 -1.946E+04 9.740E+03 1.947E+04 44.4 11 10 11 07-12-97 13:30 MSC/pal 2 Page 3 ELEMENT 12 BEAM FORCE RESULTS ( NODE 16 ) ( NODE 17 ) AXIAL -3.219E+03 V SHEAR -5._553E+OO V MOMENT 4.234E+03 V MOMENT 2.196E+04 TORSION -8.143E+02 W SHEAR 6.597E+02 W MOMFjNT -1.6'77~+02 W MOMENT -3.169E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 12 3 .141E+04 -3. 820E+04 1. 911E+04 · 3. 821E+04 87. 0 17 · 16 17 ELEMENT 13 BEAM FORCE RESULTS ( NODE 17 ·) ( NODE 18 ) AXIAL -5.403E+03 V SHEAR -5.567E+OO V MOMENT 2.196E+04 V MOMENT 9.213E+03 TORSION -1.149E+03 W SHEAR -4.744E+02 W MOMENT -1.235E+02 W MOMENT -2.730E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 13 2.911E+04 -4.052E+04 2.027E+04 4.053E+04 92.3 17 17 18 ELEMENT 16 BEAM FORCE RESULTS ( NODE 20 ) ( NODE 21 ) AXIAL -5.313E+03 V SHEAR -5.552E+OO V MOMENT -4.416E+03 V MOMENT -5.301E+03 TORSION -l.149E+03 W SHEAR -3.295E+Ol W MOMENT -5.710E+02 W MOMENT -7.202E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS -% YIELD @NODE CONNECTIVITY 16 3.061E+03 -1.407E+04 7.063E+03 1.410E+04 32.1 21 20 21 ELEMENT 20 BEAM FORCE RESULTS ( NODE 24 ) ( NODE AXIAL -4.165E+03 V SHEAR 1.098E+Ol V MOMENT -9.190E+02 V MOMENT TORSION -8.695E+02 W SHEAR 3.450E+02 W MOMENT 2.231E+02 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION 11 ) 8.349E+OJ 5.181E+02 ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 20 8.884E+03 -1.765E+04 8.840E+03 i.767E+04 40.3 11 24 11 07-12-97 13:30 MSC/pal 2 Page .c..LEMENT AXIAL TORSION 22 BEAM FORCE RESULTS ( NODE 25 ) ( NODE -3.219E+03 V SHEAR 5.536E+OO V MOMENT 4.234E+03 V MOMENT 8.141E+02 W SHEAR 6.597E+02 W MOMENT· 1.672E+02 W MOMENT \ 4 26 ) 2.196E+04 3.159E+02 '. MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 22 3 .141E+04 -;3. 820E+04 1. 911E+0-4: 3.821E+04 87.1 26 25 26 ELEMENT AXIAL TORSION 23 BEAM FORCE RESULTS ( NODE -5.403E+03 V SHEAR 5.671E+OO V MOMENT 1.149E+03 W SHEAR -4.744E+02 W ?-iOMENT 26 ) . ( NODE 2.196E+04 V MOMENT l.226E+02 W. MOMENT 27 ) 9.212E+03 2.749E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 23 2.912E+04 -4.052E+04 2.027E+04 4.053E+04 92.3 26 26 27 ELEMENT AXIAL TORSION 26 BEAM FORCE RESULTS ( NODE 29 ) ( NODE 30 ) -5.313E+03 V SHEAR 5.657E+OO V MOMENT -4.4l6E+03 V MOMENT·-5.302E+03 1.149E+03 W SHEAR -3.298E+Ol W MOMENT 5.687E+02 W MOMENT 7.206E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 26 3.062E+03 -1.407E+04 7.064E+03 1.410E+04 32.1 30 29 30 ELEMENT AXIAL TORSION 30 BEAM FORCE RESULTS ( NOOE 33 ) ( NODE 15 ) -4.165E+03 V SHEAR -l.097E+Ol V MOMENT -9.189E+02 V MOMENT 8.349E+03 8.696E+02 W SHEAR 3.450E+02 W MOMENT -2.232E+02 W MOMENT -5.178E+02 MAXIMUM STRESSES FOR BEAM · VON MISES .CRITERION . ELEMENT MAJOR MINOR ~HEAR . STRESS % YIELD @NODE CONNECTIVITY 30 8.885E+03 -l.765E+04 8.840E+03 1.767E+04 40.3 15 33 15 07-12-97 13:30 MSC/pal 2 Page 5 ELEMENT AXIAL TORSION 32 BEAM FORCE RESULTS ( NODE 34 ) ( NODE 35 ) 1.648E+04 9.209E+02 -3.125E+03 V SHEAR 1.732E+Ol V MOMENT 7.661E+02 W SHEAR 5.210E+02 W MOMENT 2.486E+03 V MOMENT 4.555E+oa W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 32 2.284E+04 -2.943E+04 l.472E+04 2.944E+04 67.1 35 34 35 ELEMENT AXIAL TORSION 33 BEAM FORCE RESULTS ( NODE 35 ) ( NODE 36 ) 4.409E+03 9.622E+02 -5.040E+03 V SHEAR 6.835E+OO V MOMENT 1.012E+03 W SHEAR -4.494E+02 W MOMENT 1.64aE+04 V MOMENT 7.786E+02 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR . STRESS % YIELD @NODE CONNECTIVITY 33 2.083E+04 -3.146E+04 1.574E+04 3.147E+04 71.7 35 35 36 ELEMENT AXIAL ')RSION 36 BEAM FORCE RESULTS ( NODE 38 ) ( NODE 39 ) -4.978E+03 V SHEAR -2.424E+Ol V MOMENT -7.722E+03 V MOMENT -7.780E+03 1.012E+03 W SHEAR -2.179E+OO W MOMENT 5.048E+02 W MOMENT -1.465E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NOOE CONNECTIVITY 36 7.162E+03 -1.762E+04 8.828E+03 1.764E+04 40.2 39 38 39 l. ELEMENT AXIAL .,ORSION 40 BEAM FORCE RESULTS ( NODE 42 ) ( NODE 15 ) -3.895E+03 V SHEAR -2.384E+Oi V MOMENT -7.696E+02 V MOMENT 9.677E+03 7.325E+02 W SHEAR 3.888E+0.2 W MOMENT -4.540E+02 W MOMENT -l.095E+03 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 40 l.125E+04 -1.946E+04 9.740E+03 1.947E+04 44.4 15 42 15 07-12-97 13:30 MSC/pal 2. Page 6 ELEMENT AXIAL TORSION 41 BEAM FORCE RESULTS ( NODE 11 ) ( NODE 43 ) 6.491E+03- 6.703E+02 -5.859E+03 V SHEAR -l.282E+02 V MOMENT 1.019E-03 W SHEAR -6.759E+02 W MOM~NT l.298E+04 V MOMENT l.901E+03 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 41 1.438E+04 -2.675E+04 l.338E+04 2. 675E+0.4 61. 0 11 11 43 ELEMENT AXIAL TORSION 50 BEAM FORCE RESULTS ( NODE 51 ) ( NODE 15 ) 1.298E+04 1.902E+03 -5. 859E+03 V SHEAR L 283E+02 V MOMENT 1.019E-03 W SHEAR 6.759E+02 W MOM~NT 6.491E+03 V MOMENT 6·. 703E+02 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEU STRESS t· YIELD @NODE CONNECTIVITY 50 1.438E+04 -2.675E+04 1.338E+04 2.675E+04 61.0 15 51 15 ELEMENT 51 BEAM FORCE RESULTS ( .NODE 7 ) ( NODE 52 ) 4.576E+OO 5.832E+02 AXIAL -7.290E+02 V SHEAR 8.099E+OO V MOMENT -2.241E-15 V MOMENT TORSION -4.119E+02 W SHEAR 6.355E-02-W MOMENT O.OOOE+OO W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 51 4.125E+02 -1.754E+03 9.075E+02 1.786~+03 4.1 52 7 -52 ELEMENT 61 BEAM FORCE RESULTS ( NODE 57 ) ( NODE 61 ) AXIAL -2.559E+03 V SHEAR -5.457E-i2 V MOMENT TORSION -3.864E+02 W SHEAR 5.434E-ll W MOMENT 1.940E-14 V MOMENT l.914E-09 2.920E-13 W MOMENT -l.919E-10 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 61 3.425E+Ol -2.736E+03 l.385E+03 2.753E+03 6.3 61 57 61 07-12-97 13:30 MSC/pal 2 Page 7 ELEMENT AXIAL 1RSION 63 BEAM FORCE RESULTS ( NODE 58 ) ( NODE 62 ) -2.559E+03 V SHEAR -1.273E-11 V MOf,IENT l.941E-14 V MOMENT 2.378E-09 3.864E+02 W SHEAR 6.753E-11 W MOMENT -2.920E-13 W MOMENT -4.487E-10 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 63 3.425E+Ol -2.736E+03 l.385E+O~ 2.753E+03 6.3 62 58 62 t. ELEMENT AXIAL ,:'ORSION 67 BEAM FORCE RESULTS ( NODE 1 ) ( NODE 12 ) 5.116E-02 1.554E-03 2.447E+03 V SHEAR 9.683E-06 V MOMENT -5.102·E-02 V MOMENT 6.397E-05 W SHEAR 2.838E-04 W MOMENT -1.932E-03 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 67 3.765E+04 O.OOOE+OO 1.883E+04 3.765E+04 85.8 1 1 12 ELEMENT 68 BEAM FORCE RESULTS ( NODE 12. ) ( NODE 13 ) AXIAL 2. 553E+03 V SHEAR -3. 02.JE-10 V MOMENT 1.153E-03 V MOMENT l .152E-03 TORSION -5.531E-09 W SHEAR -3.120E-09 W MOMENT -3~789E-04 W MOMENT -3.790E-04 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 68 3.928E+04 O.OOOE+OO 1.964E+04 3.928E+04 89.5 12 12 13 ELEMENT 71 BEAM FORCE RESULTS ( NODE 1 ) ( NODE 56 ) 2.668E+04 1.883E+04 AXIAL -l.783E+03 V SHEAR 6.619E+02 V MOMENT -5.639E+03 V MOMENT TORSION ~4.362E+02 W SHEAR 8.979E+02 W MOMENT -5.002E+03 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 71 l.195E+04 -l.341E+04 6.707E+03 1~341E+04 ~0.6 56 1 56 07-12-97 13:30 MSC/pal 2 Page 8 ELEMENT 72 BEAM FORCE.RESU~TS ( NODE 56 ) ( NODE 64 ) AXIAL -3.268E+03 V SHEAR -5.571E+02 V MOMENT TORSION -6.249E+02 W SHEAR -2.450E+02 W MOMENT 2.653E+04 V MOMENT 5.951E+03 l.897E+04 W MOMENT -2.782E+04 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 72 l.134E+04 -l.402E+04 7.-010E+03 1.402E+04 31.9 56 56 64 ELEMENT 7 3 BEAM FORCE RESULTS ( NODE 12 ) ( NODE . 5 7 ) AXIAL -l.665E+03 V SHEAR 7.890E+02 V MOMENT 5.937E+03 V MOMENT -1.182E+04 TORSION -1.455E+02 W SHEAR -4.933E+02 W MOMEN~ -7.505E+03 W MOMENT 2.090E+04 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YrELD @NODE CONNECTIVITY 73 8. 438E+03 -9. 801E+03 4. 901E+0.3 9.801E+03 22.3 57 12 57 ELEMENT 74 BEAM FORCE RESULTS ( NODE 57 ) ( NODE 65 ) AXIAL -3.366E+03 V SHEAR -6.060E+02 V MOMENT -1.203E+04 V MOMENT 5.639E+04 TORSION -4.022E+02 W SHEAR 8.145E+0-2 W MOMENT 2.070E+04 W MOMENT -3.020E+04 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION LEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 74 2.276E+04 -2.551E+04 1.276E+04 2.551E+04 58.1 65 57 65 ELEMENT 75 BEAM FORCE RESULTS ( NODE 13 ) ( NODE 58 ) l • AXIAL TORSION -1.665E+03 V SHEAR -7.890E+02 V MOMENT 5.938E+03 V MOMENT -l.182E+04 L455E+02 W SHEAR -4.933E+02 W MOMENT. 7.505E+03 W MOMENT -2.090E+04 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ~LEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 75 8. 438E+03 -9. 8.Q2E+03 4. 901E+03 9.S02E+03 22.3 58 13 58 07-12-97 13:30 MSC/pal 2 Page 9 ELEMENT AXIAL TORSION 76 BEAM FORCE RESULTS ( NODE 58 ) ( NODE -3. 366E+03 V SHEAR 6. 060E+0·2 V MOMENT -1. 203E+04 V MOMENT 4.023E+02 W SHEAR 8.145t+02 W M01'{ENT -2.070E+04 W MOMENT MAXIMUM STRESSES FOR B~AM VON MISES CRITERION 66 ) 5.639E+04 3.020E+04 ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 76 2.275E+04 ~2.551E+04 i.276E+04 2.551E+04 58.l 66 58 66 ELEMENT AXIAL TORSION 77 BEAM FORCE RESULTS ( NODE 14 ) ( NODE 59 ) -l.782E+03 V $HEAR -6.619E+02 V MOMENT -5.639E+03 V MOMENT 2.668E+04 4.362E+02 W SHEAR 8.979E+02 W MOMENT 5.003E+03 W MOMENT -1.883E+04 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 77 1.195E+04 -l.341E+04 6.707E+03 1.341E+04 30.6 59 14 59 "'!LEMENT .XIAL TORSION 78 BEAM FORCE.RESULTS ( NODE 59 ) ( NODE -3.268E+03 V SHEAR 5.571E+02 V MOMENT 2.653E+04 V MOMENT 6.250E+02 W SHEAR -2.450E+02 W MOMENT -l.897E+04 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION 67 ) 5.951E+03 2.782E+04 ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 78 l.134E+04 -l.402E+04 7.011E+03 l.402E+04 31.9 59 59 67 07-12-97 13:30 MSC/pal 2 Page 10 STATIC ANALYSIS SUBCASE NO. 2 EXTERNAL FORCES NODE DIR VALUE NODE DIR VALUE NODE QIR VALUE 64 X T 3.273E+02 ~4 y T 7.834E+Ol 64 Z T -3.366E+03 64 X R -4.512E+03 64 y R 3. 340E+·o4 64 z R 8.782E+02 65 X T 2.422E+02 65 y T 2.942E+Ol 65 z T -3.268E+03 65 X R -2.133E+03 65 y R 2.894E+04 65 z R i.490E+02 66 X T 2.422E+02 · 66 y T -2.941E+Ol 66 z T -3.268E+03 66 X R 2.133E+03 , 66 y R 2.894E+04 66 z R -l.490E+02 67 X T 3.273E+02 67 y T -7.834E+Ol 67 z T -3.366E+03 67 X R 4.512E+03 67 y R 3.340E+04 67 z R -8.782E+02 07-12-97 13:30 MSC/pal 2 Page 11 STATIC ANALYSIS SUBCASE NO. 2 ELEMENT RECOVERY t • ELEMENT 2 BEAM FORCE RESULTS ( NODE 2 ) ( NODE 3 ) \XIAL -3.019E+02 V SHEAR -1.945E+Ol V MOMENT -1.495E+03 V MOMENT -5.lOOE+03 TORSION -7.898E+02 W SHEAR -l.342E+02 W MOMENT -3.137E+02 W MOMENT -8.362E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR. MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 2 7.812E+03 -8.446E+03 4.246E+03 8.469E+03 19.3 3 2 3 ELEMENT 3 BEAM FORCE RESULTS ( NODE 3 ) ( NODE 4 ) AXIAL 2. 312E+OO V SHEAR -9 •. 091E+OO V MOMENT -5 .100E+03 V MOMENT -3. 776E+03 TORSION -1.105E+03 W SHEAR 4.926E+Ol W MOMENT -6.538E+02 W MOMENT -8.980E+02 MAXIMUM ST~ESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 3 8.177E+03 -8.172E+03 4.135E+03 8.224E+03 18.7 3 3 4 ELEMENT 7 BEAM FORCE RESULTS ( NODE 7 ) ( NODE 8 ) AXIAL 2.506E+02 V SHEAR -8.807E+OO V MOMENT 2.113E+02 V MOMENT 1.640E+02 9.651E+Ol W MOMENT -l.401E+02 TORSION -8.260E+02 W SHEAR -l.758E+OO W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 7 1.027E+03 -6.958E+02 7.219E+02 l.287E+03 2.9 7 7 8 ~LEMENT 10 BEAM FORCE RESULTS ( NODE 10 ) ( NODE 11 ) 3.370E+02 8.200E+02 AXIAL 2.221E+02 V SH~ 2.227E+Ol V MOMENT 2.269E+02 V MOMENT 2.217E+02 W MOMENT TORSION -8.260E+02 W SHEAR 4.098E+OO W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MI~OR SHEAR STRESS % YIELD @NODE CONNECTIVITY 10 1.775E+03 -1.376E+03 l.008E+03 i.907E+03 4.3 11 10 11 07-12-97 13:30 J,!SC/pal 2 Page 12 ELEMENT 12 BEAM . FORCE RESULTS ( NODE 16 ) ( NODE 1 7 ) AXIAL -3.952E+02 V SHEAR -3.405E+OO V MOMENT 2.529E+02 V MOMENT 3.734E+02 TORSION -7.905E+02 W SHEAR 4.485E+OO W MOMENT -3.091E+02 W MOMENT -4.006E+02 MAXIMUM STRESSES FOR B~ VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 12 8.904E+02 -1.539E+03 8.970E+oi l.681E+03 3.8 17 16 17 ELEMENT 13 BEAM FORCE RESUL~S ( NODE 17 ) ( NODE 18 ) AXIAL -3.609E+02 V SHEAR -3.406E+OO V MOMENT 3.734E+02 V MOMENT 1.027E+03 TORSION -1.055E+03 W SHEAR 2.432E+Ol W MOMENT -2.474E+02 W MOMENT -3.389E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ~LEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 13 l.666E+03 -2.310E+03 1.307E+03 2.476E+03 5.6 18 17 18 ELEMENT 16 BEAM FORCE RESULTS ( NODE 20 ) ( NODE 21 AXIAL -3 .. 609E+02 V SHEAR -3. 405E+OO V MOMENT 2. 334E+03 V MOMENT 2. 987E+03 TORSION -1.055E+03 W SHEAR 2.432E+Ol W MOMENT -5.219E+02 W MOMENT -6.133E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ~LEMENT MAjOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 16 4.507E+03 -5.247E+03 2.690E+03 5.315E+03 12.1 21 20 21 ELEMENT 20 BEAM FORCE RESULTS ( NODE 24 ) ( NODE 11 ) AXIAL -4.817E+Ol V SHEAR 1.255E+Ol V MOMENT _7 • .754E+Ol V MOMENT -9.914E+02 TORSION -7. 761E+02 W SHEAR -3. 979E+Ol W MOMENT 4. 55:rE+02 W MOMENT 7. 924E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 20 2.126E+03 -2.220E+03 l.195E+03 2.310E+03 5;3 11 24 11 07-12-97 13:30 MSC/pal 2 Page 13 ELEMENT AXIAL TORSION 22 BEAM FORCE RESULTS ( NODE. 25 ) ( NODE 26 ) 3.734E+02 4.006E+02 -3.952E+02 V SHEAR 3.404E+OO V MOMENT 2.529E+02 V MOMENT 7.905E+02 W SHEAR 4.486E+OO W MOMENT 3.091E+02 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 22 8.904E+02 -1.539E+03 8.970E+02 l.681E+03 3.8 26 25 26 LEMENT AXIAL TORSION 23 BEAM FORCE RESULT~ ( NODE 26 ) ( NODE 27 ) 1.027E+03 3.391E+02 -3.609E+02 V SHEAR 3.414E+OO V MOMENT 1.055E+03 W SHEAR 2.432E+Ol W MOMENT 3.734E+02 V MOMENT 2.473E+02 W MOMENT MAXIMUM STRESSES FOR BEAM-VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 23 1.665E+03 -2.310E+03 1.306E+03 2.476E+03 5.6 27 26 27 ELEMENT AXIAL TORSION 26 BEAM · FORCE RESULTS ( NODE 29 l ( NODE 30 ) 2.987E+03 6.134E+02 -3.609E+02 V SHEAR 3.413E+OO V MOMENT 1.055E+03 W SHEAR 2.432E+Ol W MOMENT 2.334E+03 V MOMENT 5.217E+02 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 26 4.507E+03 -5.247E+03 2.690E+03 S.315E+03 ~2.1 30 29 30 ELEMENT AXIAL TORSION 30 BEAM FORCE RESULTS ( NODE 33 ) ( NODE 15 ) -4.817E+Ol V SHEAR -1.255E+Ol V MOMENT 7.754E+Ol V MOMENT -9.914E+02 7.761E+02 W SHEAR -3.979E+Ol W MOMENT -4.553E+02 W MOMENT -7.925E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 30 2.126E+03 -2.220E+03 1.195E+03 2.310E+03 5.3 15 33 15 07-12-97 13:30 MSC/pal 2 Page 14 i. "Yr ELEMENT 32 BEAM FORCE RESULTS ( NODE 34 ) ( NODE 35 ) AXIAL -3.019E+02 V SHEAR l.945E+Ol V MOMENT -1.495E+03 V MOMENT -5.100E+03 TORSION. 7.897E+02 W SHEAR -l.342E+02 W MOMENT 3.137E+02 W MOMENT 8.362E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 32 7.812E+03 -8.446E+03 4.246E+03 8.469E+03 19.3 35 34 35 ELEMENT AXIAL TORSION 33 ~EAM · FORCE RESULTS ( NODE 35 ) ( NODE 36 ) 2.313E+OO V SHEAR 9.091E+OO V MOMENT -5.100E+03 V MOMENT -3.776E+03 l .105E+03 W SHEAR 4. 92.6E+Ol W MOMEN'r 6. 538E+02 W MOMENT 8. 980E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 33 8.177E+03 -8.172E+03 4.135E+03 8.224E+03 18.7 35 35 36 ELEMENT AXIAL TORSION 36 BEAM FORCE RESULTS ( NODE 38 ) ( NODE 39 ) -2.623E+Ol V SHEAR -2.199E+Ol V MOMENT -9.721E+02 V MOMENT 5.087E+02 l.105E+03 W SHEAR 5.512E+Ol W MOMENT 5.516E+02 W MOMENT -3.919E+Ol MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY . 36 2.053E+03 -2.100E+03 1.233E+03 2.3b4E+03 5.3 38 38 39 ELEMENT AXIAL TORSION 40 BEAM FORCE RESULTS ( NODE . 42 ) ( NODE 15 ) 2.221E+02 V SHEAR -2.2i7E+Ol V MOMENT 2.269E+02 V MOMENT 3.370E+02 8.260E+02 W SHEAR 4.098E+OO W MOMENT -2.217E+02 W MOMENT -8.200E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 40 1.775E+03 -1~376E+03 1.008E+03 l.907E+03 4.3 15 42 15 07-12-97 13:30 MSC/pal 2 Page 15 ELEMENT AXIAL TORSION 41 BEAM FORCE RESULTS ( NODE 11 ) ( NODE 43 ) . l.362E+02 V SHEAR -l.282E+02 V MOMENT -4.477E+02 V MOMENT -4.477E+02 l.019E-03 W SHEAR 1.529E-05 W MOMENT l.902E+03 W MOMENT 6.703E+02 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 41 3.157E+03 -2.869E+03 1.57aE+03 3.157E+03 _7.2 11 11 43 ELEMENT AXIAL TORSION 50 BEAM FORCE RESULTS ( NODE 51 ) ( NODE 15 ) l.362E+02 V SHEAR l.283E+02 V MOMENT -4.477E+02 V MOMENT -4.477E+02 l.019E-03 W SHEAR l.529E-05 W MOMENT 6.704E+02 W MOMENT l.902E+03 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 50 3.157E+03 -2.869E+03 l.578E+03 3.157E+03 7.2 15 51 15 ELEMENT 51 BEAM FORCE RESULTS ( NODE AXIAL -2.300E+02 V SHEAR 2.555E+OO V MOMENT TORSION -4.119E+02 W SHEAR 6.355E-02 W MOMENT 7 ) ( NODE 2.937E-16 V MOMENT o·. OOOE+OO W MOMENT 52 ) 4.576E+OO 1.840E+02 ~ . 10 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 51 3.516E+02 -6.889E+02 4.217E+02 7.778E+02 1.8 52 7 52 ELEMENT 61 BEAM FORCE RESULTS ( NODE 57 ) ( NODE 61 ) AXIAL 3.961E+Ol V SHE.AR -l.137E-12 V MOMENT 4.444E-14 V MOMENT 8.288E-10 3.972E-13 W MOMENT -3.964E-11 TORSION -3.060E+02 W SHEAR 2.353E-11 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 61 2.642E+02 -2.224E+02 2.433E+02 4.219E+02 1.0 61 57 61 07-12-97 13:30 MSC/pal 2 Page 16 ELEMENT AXIAL TORSION 63 BEAM FORCE RESULTS ( NODE 58 ) ( NODE 62 ) 3.961E+Ol V SHEAR -l.205E-ll V .MOMENT 4~444E-14 V MOMENT 1.125E-09 3. 060E+02 W SHEAR :,l .195E-11 W MOM.ENT -3. 972E-13 W MOMENT -4. 248E-10 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 63 2.642E+02 -2.224E+02 2.433E+02 4.220E+02 1.0 62 58 62 ELEMENT AXIAL -">RSION 67 BEAM FORCE RESULTS ( NODE 1 ) ( NODE -2.916E+02 V SHEAR 9.682.E-06 V MOMENT -5 •. 136E-02 V MOMENT 6.397E-05 W SHEAR 2.838E-04 W MOMENT -2.JOOE-03 W MOMENT 12 ) 5.082E-02 l.185E-03 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 67 O.OOOE+OO -4.486E+03 2.243E+03 4.486~+03 10.2 1 1 12 ELEMENT AXIAL TORSION 68 BEAM FORCE RESULT$ ( NODE 12 ) ( NODE 13 ) -3.404E+02 V SHEAR -3.663E-10 V MOMENT -4.656E-04 V MOMENT -4.65QE-04 4.148E-09 W SHEAR 3.647E-11 W MOMENT -1.024E-04 W MOMENT -1.026E-04 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 68 O.OOOE+OO -5.237E+03 2.619E+03 5.237E+03 11.9 12 12 13 ELEMENT 71 BEAM FORCE RESULTS ( NODE i ) ( NODE 56 ) AXIAL 3.125E+03 V SHEAR -1.193E+02 V MOMENT 9.857E+02 V MOMENT 6.100E+03 2.039E+03 W MOMENT -2.255E+03 TORSION -6.360E+02 W SHEAR 1~421E+02 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 71 3.688E+03 -1.139E+03 1.846E+03 3.690E+03 8.4 56 1 5~ 07-12-97 13:30 MSC/pal 2 Page 17 ELEMENT 72 BEAM FORCE RESULTS ( NODE 56 ) ( NODE AXIAL 3.366E+03 V SHEAR 7.834E+Ol V MOM~NT 5.902E+03 V MOMENT TORSION -8.782E+02 W SHEAR 3.273E+02 W MOMENT -2.068E+03 W MOMENT 64 ) 3.340E+04 4.512E+03 ' . MAXIMUM STRESSES FOR BEAM ELEMENT MAJOR MINOR SHEAR 72 1.454E+04 -1.179E+04 7.273E+03 41 VON MISES CRITER10N STRESS % YIELD @NODE CONNECTIVITY l.454E+04 33.1 64 56 64 ELEMENT AXIAL TORSION 73 BEAM FORCE RESULTS ( NODE 12 ) ( NODE 57 ) J.242E+03 V SHEAR 7.818E+OO V MOMENT -6.874E+02 V MOMENT 8.761E+03 5.435E+Ol W SHEAR 2.625E+d2 W MOMENT -4.630E+02 W MOMENT -l.815E+02 MAXIMUM STRESS-ES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 73 4.780E+03 -2.126E+03 2.390E+03 4.780E+03 10.9 57 12 57 ELEMENT 74 BEAM FORCE RESULTS ( NODE 57 ) ( NODE 65 ) 2.894E+04 2 .1_33E+03 AXIAL 3.268E+03 V SHEAR 2.942E+Oi V MOMENT 8.594E+03 V MOMENT TORSION -1.490E+o2·w SHEAR 2.422E+02 W MOMENT -3.379E+02 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 74 l.274E+04 -l.007E+04 6.372E+03 1.274E+04 · 29.0 65 57 65 ELEMENT 75 BEAM FORCE RESULTS ( NODE 13 ) ( NODE 58 ) 8.761E+03 1.815E+02 AXIAL 3.242E+03 V SHEAR -7.818E+OO V MOMENT -6.874E+02 V MOMENT TORSION -5.432E+Ol W SHEAR 2.625E+02 W MOMENT 4.630E+02 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ~~EMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY 75 4.780E+03 -2.126E+03 2.390E+03 4.780E+03 10.9 58 13 58 07-12-97 13:30 MSC/pal 2 Page 18 ELEMENT AXIAL . 76 BEAM FORCE RESULTS ( NODE 58 ) ( NODE 66 ) TORSION 3_. 268E+03. V SHEAR -2. 941E+01 V MOMENT 1.490E+02 W SHEAR 2.422E+02 W MOMENT 8.594E+03 V MOMENT 2.894E+04 3.379E+02 W MOMENT -2.133E+03 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % Y:J:ELD @NODE CONNECTIVITY 76 1.274E+04 -1.007E+04 6.372E+03 l.274E+04 29.0 66 58 66 ELEMENT AXIAL TORSION 77 BEAM FORCE RESULTS ( NODE 14_ ) ( NODE 59 ) 6.100E+03 2.255E+03 3.125E+03 V SHEAR 1.193E+02 V MOMENT 9.858E+02 V MOMENT 6.360E+02 W SHEAA l.421E+02 W MOMENT -2.03~E+03 W MOMENT MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR $TRESS % YIELD @NODE CONNECTIVITY 77 3. 688E+03 -1.139E+03 l •. 846E+03 3.690E+03 8.4 59 14 59 " ELEMENT "IAL .1.IJRSION 78 BEAM FORCE RESULTS ( NODE 59 ) ( NODE 67 ) 3.366E+03 V SHEAR -7.834E+Ol V MOMENT 8.782E+02 W SHEAR 3.273E+02 W MOMENT 5.902E+03 V MOMENT 3.340E+04 2.068E+03 W MOMENT -4.512E+03 MAXIMUM STRESSES FOR BEAM VON MISES CRITERION ELEMENT MAJOR MINOR SHEAR STRESS % YIELD @NODE CONNECTIVITY Lf 2.. 78 l.454E+04 -l.179E+04 7.273E+03 1.454J::+04 33.1 67 59 67 t. • I\ CASTEGH CONSi.JL TiNG ::NGINE:RS 4455 TORRANCE BLVD,# 414 TORRANCE.CA. 90503 ENGINEER: D.J.CASTAN PROJECT NAME :MODEL# 6 REPORT NO : 9773 DA TE: 07 /12/97 COLUMN BUCKLING: , 10 ft.COLUMN,80 MPH PAGE.. L/.3 CONSERVATIVELY COMBINING WORST CASE AXIAL AND BENDING MOMENTS MW = 30200-lbf in MV = 56390-lbfin FB = 39501-psi Pa = 3366--lbf, 4.S"DIA x· 7GA. A = 2.4429-in2 f :: 5. 7087· in 4 S -=2.5372-in~ r =1.5287-in L -= 120-in K = 1.7 K-L' AK=-· r AK =133.447 Fa = 8440-1.33-psi Pa fa-=-fa=I377.87l•psi .A Ra = fa Ra =0.i23 Fa MW tbw = -tbw = 11902. 885 •psi s MV tbv = -· -tbv = 22225.288 •psi / 2 2 tbt = ,y tbw '!" tbv RT =Ra-Cm·tbt ( I -Ra)-FB tbt RT·=Ra+- FB tbt = 25211.943 •psi RT =0.741 RT=0.761 4.5" DIA x 7 GA. COLUMNS 0.K. s Cm =.85 < 1.0, O.K. < 1.0, O.K. t, • I\ ENGINEER: D.J.CASTAN CASTECH CONSULTING ENGINEERS · 4455 TORRANCE BLVD.,# 414 TORRANCE,CA., 90503 PROJECT: LEGO LAND-.MODEL#6 PROJECT NO. 0085 DA TE :06/14/00 COLUMN DESIGN : 4.5" DIA. X 7 GA. TO :=4.S·in T := .18·in TI :=T0-2·T ._TI=4.14o1n 1!( 2 2) ,2 A :=-· TO -TI . A= 2.443 om . I:= T04 -Tf ·1t 64 I= 5.709oin4 4 ·-2·1 S.--TO ,_K-L AK,-- r s = 2.s31 oin3 . r := 11 ~;: r = 1.529 oi.n K := 1.7 AK= 133.449 FROM AISC,8th ED. · Fa :=8440·psi Faa := 1.33-Fa FY :=45000-psi FB := .66· l.33·FY FB = 39501. cpsi LOADS ON COLUMN : Pa :=3366·lbf LATERAL LOAD : V :=533-lbf NIB :=63968-lbf·in STRESSES: ~ ,_Pa 1a,-- A fa= 1377.867cpsi ,_MB fb,--s fb = 25212.02Jcpsi USING l;Q. 1.6-1 B : Cm :=.85 fa Ra:=-Faa RT:=Ra+~ FB RT= 0.761 4.5" DIA . x 7 GA. COLUMN O.K. Ra=0.123 < 1.0 L := 120-in Faa = 11225.2 cpsi O.K. PAGE :A1 CASTECH CONSUL TING ENGINEERS ENGINEER: D.J.CASTAN PROJECT :LEGO LAND -MODEL# 6 PROJECT NO. 0085 DAT!; : 06/14/00 . FOOTING SIZING :ALLOWABLE PARAMETERS lbf Qu:=100(}_ ft2 S := JOO·lbf ft3 Quu := 1.33-Qu Su :=l.33-S SECTION PARAMETERS: 2.5' DIA. W :=2.5·:ft Ms :=:MB 2 ,_1t·W AF,-- 4 Ms = 5330.667°lbf,ft lbf Quu= 1330°- ft2 Su= 133 )bf ti AF= 4.909 oft2 PAGE:A2 ,_ Pa q,-- AF lbf q = 685.716 o_ ft2 lbf < Quu:;: 1330°- ft2 O.K. FOOTING DEPTH: USC 97, 1806.8.2.1 ·Pe ,_Ms ,--Pe= 533.067 °lbf L d,_A (I·. P¥4.36·L)· ,--· + +--2 A · d = 5.73•ft USE : 2.5 FT. DIA. x6.0 FT, DEEP FOOTING deff := 1.9-ft A :=Z.34-Pe Suu-W d dq:=- 3 Suu :=Su-deff dq = 1.91 •ft > deff = 1.9•:ft O.K. CASTECH CONSUL TING ENGINEERS ENGINEER: D.J.CASTAN PROJECT : LEGO LAND -MODEL# 6 REPORT NO. 0085 DATE : 06/14/00 FOOTING FLEXURE : fc :=3000·psi fy :=60000-psi USING # 4 BARS As := .20-irr2 N :=l FOR 2.5' DIA. FOOTING As:=N·As Be := 1.8.0·in Da :=24-in (Da)· . D :=Da-.5756· 2 -3·m T :=fy·As T a:=---.85,fc-Be T = 12000.018°lbf a= 0.261 oin b = 14.09~ oin Mu= 150790.703 °lbf·in MT := 1.8·:tvIB MT= 1 H5142.4°lbf·in < Mu= 150790.703 °lbf.in 2'-6" DIA. x 6' .. 0" DEEP , WITH 4 -# 4 BARS , fc=3000PSI , fy=60000PSI PAGE: A3 O.K. CASTECH CONSUL TING ENGINEERS 4455 TORRANCE BLVD.,# 414 TORRANCE.CA., 90503 ENGINEER: D.J.CASTAN PROJECT NAME :MODEL# 6 REPORT NO :9773 DATE: 07/07/97 FOOTING DEPTH : FOR 10' COLUMN, 80 MPH TRY 2.5 FT. DIA. FOOTING D = 2.5-ft 1t·IY ~.2 AF = 4 AF =4.909•rr Pa = 3366-lbf Qu .= 1330-~ Mw =63968·in·lbf Pa q =-· AF B =D S = 199.5·~ (l\ /4.25-MO\ \3/ d = \ B·S } d =3.568•ft. . lbf q =685.716• ft2 MIN FTG. DIMENSIONS : 2.5 FT DIA. x 3.6 FT. DEEP FOOTING FLEXURE : fc . = 3000-psi fy .=60000-psi M .=Mw PAGE: 44 MO =5330.667•ft·lbf lbf < Qu =1330 • ft2 Be·= 19.90·in TRY#4BARS AS:= .20-in2 AS =0.2•in2 T =fy·AS T a : = -.8~5--fc--Bc-a =0;236•in de .=30-in Mu =322723.027 •lbf ·in MF = 1.7-M MF =108745.6•lbf·in < Mu ~322723.027 •lbf·in USE #4 BARS AS SHOWN INDETAIL,fy=60000PSI,fc=3000PSI SUMMARY: 2.5 FT. DIA. x 3.6 FT. DEEP 4-# 4 BARS IN CIRCULAR ·PATTERN, fy=60000PSI f'c=3000PSI CASTECH CONSUL TING ENGINEERS 4455 TORRANCE BLVD.,# 414 TORRANCE.CA.. 90503 ENGINEER : D.J.CASTAN PROJECT NAME :MODEL # 6 REPORT NO : 9773 DATE: 07/12/97 BASE PLATE DESIGN : DOWN WIND Pa = • 3366-lbf Mb O 63968 in-lbf S = !016·1bf ANCHOR SOL TS LOAD : Db =9.0-in Pb =Pa_ Mb 4 2-Db 3i4" DIA. x 6" ANCHOR 8OLTS,fc=3000PSI: Pu = 2700-lbf Puu = l.33· Pu Puu =3591 •lbf Ps = 4250-lbf s Rs=- Pss 5 5 Rs =0.18 Pss = 1.33· Ps Pss = 5652.5 •lbf Rt = Pb Puu Rt =0.755 RT -Rt3 · Rs3 RT =0.684 < 1.0, O.K. BASE PLATE; W = 12-in DP =4.5-in . ED = 1.5-in PAGE.· 45 Pb =2712.278•lbf W DP Dp =-,--ED--Mp =2-Pb-Dp Mp= 12205.25•in·lbf 2 2 Tp = .500-in FY = 36000· psi FB = .75· I.33-FY fp =24410.S•psi 6-Mp fp ·-· ---. 2 WTp fp =24410.5-psi FB =35910•psi < FB =359I0•psi USE: 12" x 12" x 1/2" A36 PLATE,WITH STIFFNERS O.K. DESIGN SKETCHES f r 114• / 3/B·, 112· Stl Co.lole 30' 15' Additional Bro.cing <See To.lole when Req'cl) 16' 8' 40' 16' If 4' 61 _i_ A B X ! fD 1 Additiono.l Bro.cing <See to.lole when req'd) 6. -. _Jj_· .---~-~2 ties View A-A (Not to Seo.le) o.t 2 places #4 Reloo.r Df :b 0 EMBED . 1'-6' BELOW SOIL. LEVEL DB ff A307 SOLT A 36 PLATE 0 D 0 0 ~. o· VIEW ( 8 ) . { NQT TO SCAL~ ) . VIEW ( C ) · ( NOT TO SCALE ) , B % POST E70XX 3/16 ·(J 1/2 # 4 REBAR VIE\./ - F - C NOT TO SCALE) TAK \./ELD C Sheecl DESIGN DETAIL TABLE (NIOD 6) WI:"lol> SP. H A 8 DP . D.B (A.307) DF (Fr) FD (FT) B.P. SIZE 8.P.BOLT SLEEVE STRL'TS POST 2 7/8" PIA 4 1/2" DIA · 1/2" DIA 12"X12'' 3/4" DIA AND 8 IT X l2GA. X7GA. 3 318" DIA X 33/4" 2' 6" DIA 3' 6" X 1/2" X 6" NA HIP BRACES : REQ. - yi ~ POST 2 7/8" DIA 4 1/2" DIA 1/2" DlA AND SO MPH lOIT X 12 GA. X7GA. 3 3/8" DIA X J3/4". 21 6" DIA 3' 6" . NA HIP BRACES REQ. 1 1 POST 2 7/8" DIA 41/2" DIA 1/2" DIA AND 12 FT X 12 GA. X7GA. 3 3/8" DIA X ·3 3/4" 2' .6" DIA 3' 6" NA HIP ff BRACES . REQ. POST 4" DIA 6" X 6" 5/8" DIA. AND SFT X8GA. X3/.16" 3 7/8" DIA X 4 3/4" 3" DIA 4' 6" NA NA NA HIP BRA-CES REQ. POST 4" DIA 6" X 6" 518" DIA AND llOMPH lOFT X8GA. X 3/16" 3 7/8~ DIA X 4 3/4" 3" DIA 4' 6" NA NA NA HIP BRACES REQ. POST 4" DIA 6" XIS". 5/8" DIA AND 12 FT X8GA. X 3/16" 3 7/8" DIA X 4 3/4" S" DIA 4' 7" NA NA NA HIP BRACES REQ. NOTES: [) SEE DESIGN SKETCHES FOR SYMBOL DEFiNTION. 2) STRUCTURE l)'SES 3/8" PERIMETER CABLE FOR 80 MPH, AND 1/2" FOR 110 MPH. Pagel '. ' '. ' I i'' i . . ' ' . ,-. ' ' ' i • ' l' .... l ' ' . i'· I r I ,. i I. I ' :_ ... ,., ..,, '' ' ' .. i: l•:_-. ,.--'. ' . i •'. ~- 1: ,: f./ ,· --· ' ;.: . f ,. r . r· l ,· lJ, • . ' t-. ' . L-1 r .. i j . 1 i • ' ---'· ': '; . , ... ~ -. ' .. ,.-•·, - -: ~ '" y -~-. EQUAL' . . ' '· 26'"-Q" ... 8' -:8" ··:· · -,,,, . ' . ,, ' EQUAL. . {Of POSf . . 0 I . ' r~':-i-i.--·{ Of POSf ' 0 I . 0 '<I' • 0 . I <D 0 I . <Xl ' 0 I .. <D -,'1 ·-:i. :::) 0 w -<Xl I <Xl ~ ---' <( .. .. ' 0 I 0 0 I 0 SECTION X-X 4 :mm•:c•1•··,iN@Himm;m:;mtttk•@ mu::rn:rnrtrliln••rnnm•\ ·<n•n 8 i'ig:@MlIB:@@@lWtE:@EiM?t::t:B@t}B@@t:l ::xrnt&t: Hlli@l:iliu'' 1 ([_ Of P0:3i]4.--'--->l.-l.....;..,1-1 ·1-~t-"<--([_ Of POSf y ?/ 16" (iYP). } X -'· PLAN VIEW "---2 HOLES 1 ·5'-3" (o--......--<f70XX 0 I 22 . POST BRA.CE · CONNECTION DETAIL N. f. 5. ' "..---'----· 3/8" LUG .--i -•.i : ·,,.;.. _, .. ~ .-·' : - I '! •. "'· . ' t CABLE ATTACHMENT . . -,. ',' . ; . "' '·;' :, .. ' ·,< >' . ' . ~ -. - CABLE POCKET " . FABRIC ' ATTACHMENT X ....-----, 4 0-n--<f70XX FP ~----TACK WELD ( ,-YP.) SECTION Y-Y ' L ?/16" (-rYf') 6" VfRlf5.- ' 1 I ' I I I <t.. -I--'---, A HIP RAFTER CONNECTION DETAIL 50J.J ,_____ B N, f. 5. MULTI-STRUCTURE INTER-CONNECTOR N, f.5. 12r---..... 2 BOLTS ?/ 16" ( -rYf'.) 10 'TYPICAL 4 PLACES ' . . . D HIP BRACE CONNECTION DETAIL 1-----'sc"-'-PJ..-'---r --1 N. f.S. E 3 " ' ~ Q 0 ~I I \!J '<I' ?/16" 3 ,__ _ _, ---\ _,...... . .:.:.:. .. . l ' L --ti--'' ( -rYf'.) OPTIONAL N. f. 5, C 19 Rebors 2 ea #2 Ties I 2 ea #2 Ties 4 ea #4 Rebors VIEW -"y" REBAR CAGE FOOTING DETAIL 5CAIX ,__ __ ~ F N. 1. 5. GENERAL NOTES: 1. ALL STEEL TO CONFORM TO ASTM SPEC A-36 OR TO ASTM SPEC A-500 GRADE B (50 KSI) AS NOTED. 2. ALL WELDING TO CONFORM WITH AMERICAN WELDING SOCIE1Y STANDARDS. ALL WELDS TO BE 3/16" FILLET E70XX ELECTRODES UNLESS NOTED OTHERWISE. 3. ALL FOOTING REBAR$ TO BE 60 KSI STEEL 4. CONC. FOOTING TO BE f'c=3000 PSI (IF REQUIRED) 5. ALL CONSTRUCTION SHALL COMPLY WITH THE UNIFORM BUILDING CODE OF 1997. 6. STRUCTURE IS DESIGNED FOR 80 MPH WIND LOAD 7. ITEMS 1 THRU 5 IN TABLE ARE MADE WITH GALVANIZED GAT~;J:,IELD T ALLIED TUu;,c---AJ'ID CONDUIT S flee,;__ ( ~~,0~ f ...,,._u,~!L +eoQ... C,c.-.. S,So "s. a..-~c {', ~ W 0-e. l d.,"..:) ' _,,...., -x,~ .. 22 PIN 1/2"¢x1 1/8" LONG SOLID ROD (A36) HEX BOLT, FLAT WASHER, 5/8"¢ x 6" LONG BOLT 21 LOCK WASHER, & HEX NUT (A307) 13 TPI 2 Q ADJUSTABLE LEG BRACE 19 EMBED BAR 18 POST BRACE END PLATE 1 7 FABRIC COVER 16 REBAR CAGE 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 CONNECTOR PLATE (IF REQUIRED) PERIMETER CABLE GUSSET HEX BOLT, FLAT WASHER, LOCK WASHER, & HEX NUT HEX BOLT, FLAT WASHER, LOCK WASHER, & HEX NUT TAB CONNECTOR HIP BRACE END PLATE POST END PLATE CABLE CLAMPS INTERNAL CONNECTOR POST BRACE RIDGE POST HIP BRACE HIP RAnER ~~~ NOMENCLATURE 5"¢ x 7 GA. TUBING 1 /2" #4 REBAR 2 7 /8"¢x3/8"THK. STL. PLATE (A36) FIRE RATED Fl,BRIC COVER MESH, POLYETHELENE 4 EA #4 REBARS & 2 EA #2 TIES 5 1/2"x10 1 /2"x3/8" THK. S L. [A36) 1 3/8"¢ GALV. CABLE 1 /2"x1 ''THK FLAT BAR (A36) 1 /2"¢x1 1 /2"LONG BOLT (A307) 13 TPI (8 REQ'D) 1/2"¢ x 3 1/2" LONG BOLT (A307) 13 TPI 2 1 /2"x3/8''THK. STL. FLAT BAR (A36) 3 3/8"¢x3/8"THK. STL. PLATE (A36) 5"¢x3/8"THK. STL. PLATE (A36) 3/8" CABLE CLAMP (4 PER UNIT) 2 5/8"¢ X11 GA. TUBING 2 3/8"¢ x13 GA GALV. TUBING 2 7/8"¢ x12 GA GALV. TU81NG 4 1 /2"¢ x7 GA GALV. TUBING 2 7 /8"¢ x12 GA GALV. TUBING 2 7 /8"¢ x12 GA GALV. TUBING DESCRIPTION 80 MPH . 0 I z 0 .... E-< <i: u 3 FILE NAME: TOUVER\A12 •• >, = ~ 0 ~ p.. ~ >, = z ~ ~ ::e <i: t::i . <i: O· 0 I 10 0 I co I!: 0 <" i:l . 0 z = 0 ... .'.\. ., I l ~-' ., --,f . ·,, , .. ''. 'ii " '.,i<I l :, ,-i l • 1i' ' . 1 ', ' ,, ,, .'., ., . . , j ' .-) i .• ., • ·1 . ,j . . • .. . \ ''. , .. . '·.-~ . :.. .',. :•.,,· .. ; ", • L~ -•,, • ,. '~'. l----__:_12:::.:.7.:.::.8:.__--1.::3:::::_5:.:::.81-------.:::.:86:_-__-4,__+·---=-86"-'-.-'--4 ___,_3=-=5-'-. 8.,___1_27_.8_---J 8mm PLATE 250 500 SECTION B-B, 1: 5 l=8mm a=5mm 0 t') 100 0 0 N DETAIL 2, 1: 5 250 15mm PLATE 0500 ' I Lfl en N n 0 0 0 ,..., 0 0 t') 0 0 N ~ 0 0 0 I I I I I I I I I I I I I I I I 11 111 II II II I 11 II 11 111 I I ii 11 II II ii II I II II lLILJIJj ELEVATION, 1: 20 INT. PIPE: 219,1x6,3 mm COLLAR 0350x10 mm WELDED ON WITH 5 mm FILLET WELD PIPE SHOULD BE CHOSEN SO THAT AS LITTLE SUP AS POSSIBLE IS ACHIEVED BETWEEN EXT. AND INT. PIPE WITH REGARD TO TOLLE- RANCES ALLOWED ON PIPE DIMENSION. EXT. PIPE: 244,5x10 mm COLLAR 0350x10 mm WELDED ON WITH 5 mm FILLET WELD COLLAR <i!470x10 mm i'1UDED ON WITH 5 mm FILLET WELD GROUTED WITH CEMENT MORTAR 0 ,. rrtn • " ' I II -~ f 350 219.1 dy INT PIPE -,---·-1---......... I I I I rrtn .----1-----" ' ;:: = ---1----= II I ~ I I I __ L __ 224.5 di EXT. PIPE (THEORETICALLY) 244.5 dy EXT • PIPE DETAIL 1, 1:5 ..-------=2:..:..44-'-".5"-------i dy EXT. PIPE 219· 1 dy INT. PIPE I I ---+--BOLT NOS, 6 M12 77 77 77 77 175 175 350 SECTION A-A, 1: 5 • d t It / L:\LEG0\5726\57260001 m I co nsu a s ph.+45 97 22 11 33 Job No.: 5726 NOTE: STRUCTURAL STEEL: Fy ~ 235 MPa BOLTS: GRADE 8.8 ALL STEEL TO BE HOT GALVANIZED. THICKNESS min. 120 µm SUFFICIENT OPENINGS FOR THE ZINK INLETS AND OUTLETS IN SOLID ITEMS MUST BE PROVIDED. ALL MEASUREMENTS ARE mm REV.A: 17.04.98 ~ [b~@@ [fu T~TllE: COLUMN FOR ICONS ATTIRACT~ON: Date: Sca~e: !By: Sketch: LEGOLAND CARLSBAD 21.05.97 1: 20/5 AM 00.01 A ~IHIOW~ & !E\\f!EINl'f~ -~!IL[LIUJINIICJ