HomeMy WebLinkAbout1 LEGOLAND DR; ; CB130627; Permit05-03-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit PermitNo: CB130627 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 1 LEGOLAND DR CBAD Tl Sub Type COMM 2111000900 Lot# 0 $318,148 00 Construction Type 5B Reference # LEGOLAND 6,325 SF Tl TO EXIST UPPER DECK RESTAURANT status ISSUED Applied 03/14/2013 Entered By JMA Plan Approved- 05/03/2013 Issued 05/03/2013 Inspect Area Plan Check # Applicant GERALD MICHAELS STE B 17848 SKY PARKCR IRVINE CA 92614 949-757-3240 Owner LEGOLAND CALIFORNIA LLC <LF> PLAY U S ACQUISI c/o PROPERTY TAX SERVICE CO PO BOX 543185 DALLAS TX 75354 Building Permit $1,554 10 Meter Size Add'l Building Permit Fee $0 00 Add'l Reel Water Con Fee $0 00 Plan Check $1,087 87 Meter Fee $0.00 Add'l Building Permit Fee $0 00 SDCWA Fee $0 00 Plan Check Discount $0 00 CFD Payoff Fee $0 00 Strong Motion Fee $66 81 PFF (3105540) $0 00 Park Fee $0 00 PFF (4305540) $0 00 LFM Fee $0 00 License Tax (3104193) $0 00 Bndge Fee $0 00 License Tax (4304193) $0 00 BTD #2 Fee $0 00 Traffic Impact Fee (3105541) $0 00 BTD #3 Fee $0 00 Traffic Impact Fee (4305541) $0 00 Renewal Fee $0 00 PLUMBING TOTAL $80 00 Add'l Renewal Fee $0 00 ELECTRICAL TOTAL $11302 Other Building Fee $0 00 MECHANICAL TOTAL $53 61 Pot Water Con Fee $0 00 Master Drainage Fee $0 00 Meter Size Sewer Fee $0 00 Add'l Pot Water Con Fee $0 00 Redev Parking Fee $0 00 Reel Water Con Fee $0 00 Additional Fees $0 00 Green Bldg Stands (SB1473) Fee $12 00 HMP Fee 97 Fire Expedidted Plan Review $835 00 Green Bldg Standards Plan Chk ?•? TOTAL PERMIT FEES $3,802 41 Total Fees $3,802 41 Total Paynnents To Date $3,802 41 Balance Due: $0.00 Inspector FINAL/APPROVAL Date ^-/^ Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refenred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition Vou are hereby FURTHER NOTIFIED thai your right to protest (he specified fees/exacfions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired • ••IklW't • 11« ^ CITY OF CARLSBAD Building Permit Appiication 1635 Faraday Ave., Carlsbad, CA 92008 Ph- 760-602-2719 Fax: 760-602-8558 email, buldling@carlsbadca.gov www carlsbadca.gov Plan Check No. Est. Value ^3t<P) l^-cf" Plan Ck. Deposit Date SWPP JOB ADDRESS t 'ROJECT # 3 [LOTS I PHASE # I # OF UNITS I # BEDROO SUITE#/SPACE#/UNIT# APN 2.\\ CT/PROJECT APPLICANT NAME (Primary Contact) CA-er«^x<^ t.V> S APPLICANT NAME (Secondary Contact) i}»«Aj ADDRESS ' STATE zip ADDRESS CITY CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL PROPERTY OWNER NAME .r Lc «\e» \(xv^a, C«\\ Cl CONTRACTOR' ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP wot PHONE FAX PHONE FAX EMAIL EMAIL ARCH/DESIGNER NAME & ADDRESS I STATE LIC # fQar 70^1 R Rticinocc anH Prnfoccinnc PnHa onw r\\f\i nr Pm intv/ ui/hirh ram iiroc a ncirmit tc STATE LIC # CITY BUS LIC# I I I TT (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, pnor to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions ofthe Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 70315 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)) C Workers' Compensation Declaration / hereby affirm under penalty of perjury one ofthe foltowing declarations. I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance ot the work for which this permit is issued I have and will maintain workers' compensaton.ias required by Section 3700 of the Labor Code, for the performance of the work for which tjiispermit is issued My workers' compensation insurance earner and policy number are Insurance Go hO/S da fe Tyt$Ur^M^^ "yf/^ICff Policy No Sk/7. tO I It Expiration Date (<7 /' This section need not be completed if the permit is for one hundred dollars ($100) or less n Certificate of Exemption: I certify that in the performance ot the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING' Failure to secure workers'compensation coverage is unlawful, and shall subject an employerto criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attomey's fees. vgS" CONTRACTOR SIGNATURE / hereby affimi fhaf / am exempt from Contractor's License Law for the foltowing reason • I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does nol apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) • I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply lo an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractors License Law) D I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide Ihe major labor and matenals for construction of the proposed property improvement • Yes • No 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (finn) to provide the proposed construction (include name address / phone / contractors' license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number) 6 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work) vglTPROPERTY OWNER SIGNATURE •AGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or nsk management and prevention program under Sections 25505, 25533 or 26534 of the Presley-Tanner Hazardous Substance Account Act' • Yes • No Is the applicant or future building occupant required to obtain a permit from the air pollution control distnct or air quality management distncf • Yes • No Is the facility to be constructed within 1,000feetoftheouterboundaryofaschoolsite'' OYes jBNo IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender's Address I certily thati have read ttie application and state thatthe above infonnation isconectand thatthe infomiation on ttie plans IS I agree to complywith all City ordinances and State laws relating to building construction. I hereby aultionze representative of the City of Carlsbad to enter upon the above mentioned property fbr inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILfFIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA pennit is required for excavatons over 5'0' deep and demoliton or construction of stuctJres over 3 stones in height EXPIRATION Eveiy permit issued by the Building Official under the provisions of this Code shall expire by limitaton and become null and void if the building or virark authonzed by such permit is not commenced within 180 days from tie date of such permit or if the building or work auttionzed by such permit is suspended or abandoned at any tme after tie work is commenced for a penod of 180 days (Secton 106 4 4 Unifomi Building Code) APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. F f C A CY (Commeri roject; Fax (760) 602-8560, Email vyww buildina(a)carlsbadca gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, Califomia 92008 C0#: (Office Use Only) CONTACT NAIVIE OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE EMAIL OCCUPANT'S BUS LIC No DELIVERY OPTIONS • PICK UP: • CONTACT (Listed above) • OCCUPANT (Listed above) • CONTRACTOR (On Pg 1) • MAIL TO: • CONTACT (Listed above) • OCCUPANT (Listed above) • CONTRACTOR (On Pg 1) • MAIL / FAX TO OTHER: • ASSOCIATED CB#- • NO CHANGE IN USE / NO CONSTRUCTION • CHANGE OF USE / NO CONSTRUCTION ^APPLICANT'S SIGNATURE DATE Inspection List Permit#: CB130627 Type: Tl COMM LEGOLAND: 6,325 SF Tl TO EXIST UPPER DECK RESTAURANT Date Inspection Item Inspector Act 06/14/2013 19 Final Structural -Rl 06/13/2013 89 Final Combo PD AP 05/23/2013 84 Rough Combo PD AP 05/15/2013 44 Rough/Ducts/Dampers PD AP 05/14/2013 14 Frame/Steel/Bolting/Weldin PD AP 05/14/2013 24 Rough/Topout PD AP 05/06/2013 21 Underground/Under Floor PD AP 05/06/2013 31 Underground/Condurt-Winn PD AP Comments Friday, June 14, 2013 Page 1 of 1 J"". 14. 2013 7:56AM" Jo. 3427 P, 1/1 CB130627 1 LEGOUND DR LEGOLAND 6,325 SF Tl TO EXIST UPPER DECK RESTAURANT Tl COMM Lot# GERALD MICHAELS REC6RD COPY B?rr^ INSPECTION RECORD EI INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB m CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION B FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.tarbbadca.p0v/Bmidin9 AND CLICK ON DATE: IF "YES" IS ct^ECKED BELOW THAT DIVISION'S APPROVAI- IS REQUIRED PRIOR TO REQUESTING A FINAL BUILDING INSPECTION. IF YOU MAVE ANV QUESTIONS PLEASE CALL THE APPLH"-ABLE DIVISIONS AT THE PHONE NUMBERS PROVIDED EELOW. APTER ALL REQUIRED APPROVALS ARE SIGNED OFF- FAX TO 76O-S02-85SO. SMAIL TO BLDGIN5PECTIPNS@CAHLSBAOCA.FIOV OP BRING IN A COPY OF THIS cAflD TO; 163S FARADAY AVE.. CAHLSBAD. CA 920O8. BUILDINQ INSPECTORS CAN BE , BEACHED AT 760-602-2700 BETWEEN 7:30 AM - 8;00 AM THE DAY OP VOUR INSPECTION. I NO Required Prior to Requesting Building Flniti ir Checked YES Date Inspector Notes A Landscape 760^44^463 /^iiow4Shoaw CM&i (Englneer<ng ln<rpectl(inf| 76&43e-389l CaU6eroFe2pm J Fire Prevention 760402-4660 /*tfaw46 hours Type ef Inspection Type of Inspection 1 Co[,E ^ BUILDING 1 Date Inspector , CODE « ELECTRICAL 1 Date laspector #U FOUNDATION #31 • EUCTRIC UNDERGROUND DUFER Arr<r #12 REINFORCED STEEL #34 ROUGH CLECmiC #es MASONRT PRE QROUT #33 • EUCTRIC SERVICE • TEMPORARY • QROUT • WAIL DRAINS #35 PHOTOVOLTAIC #10 TILTPANELS #39 FINAL #11 POUR STRIPS CODE >• MECHANICAL «11 COLUMN FOOTINOS #41 UNDERGROUND DUCTS &PIPIN(( #14 SUBFRAME • FLOOR nCEIUNQ #44 DOUCTA PLENUM • REF. PIPING #15 ROOFSHEATHINQ #43 HEAT-AIR COND. SYSTEMS #13 EXT, SHEAR PANELS #49 FINAL #16 INSULATION coCE f COMBO INSPECTION #18 EXTERIOR UTH #81 UNDEHSROUNO (11,12,21,31) #17 INTERIOR UTH & DRYWALL m DRyWALL,E}CriATH,QASTES (17,18,23) #51 P00LEX0V5TEEL/BOKD/FENCE #83 ROOFSHEATING, EXTSHEAR (13,1E) /y #55 PREPLASTER #84 FRAME ROUGH COMBO (14,24,34/44) ir-/f- n #19 FINAI. #89 FINAL OCCUPANCY (19,29,39,49) ff -I S-13 Coca tl PLUMBING Date Inspector r m • SEWER & BL/CO • PL/CO ? FIRE Date Irtfpoctoir m UNDERQROUND awASTE nwni #24 TOPOUT • WASTE DWTR VS UNDERGROUND VISUAL #27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO #23 • GAS TEST • OAS PIPING A/SUNDERGROUND FLUSH • J / #25 WATER HEATER VS OVERHEAD VISUAL #28 SOLAR WATER A/S OVERHEAD HYDROSTATIC #29 FINAL A/SFINAL (UaAA CODS s STORM WATER F/A ROUGH-IN h #600 PRE-CONSTRUCTION MEETINO F/A FINAL #603 FOLLOW UP INSPECTION FDIED EXTINGUISHING SYSTEM ROUGH-IN #605 NOTICE TD CLEAN FRED EXTING SYSTEM HYDROSrAIIC TEST #607 WRITTEN WARNINQ FRED EXTINGUISHING SYSTCM RNAL #609 NOTICE OFVIOUnON MEDICAL GAS PRESSURETEST /A #610 VERBALVARNINQ MEDICAL OAS FINAL REVIOflOIZ SEE BACK FOR 8PEC1AL NOTES EsGil Corporation In (Partnership with government for (BuiCding Safety DATE: April 30, 2013 • AEEUQANT JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 13-0627 SET; III PROJECT ADDRESS: 1 Legoland Dr. PROJECT NAME: Legoland Upper Deck Restaurant TI ^ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: IXI EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person • REMARKS: By: Eric Jensen Enclosures: EsGil Corporation IE! GA • EJ • PC 4/24/2013 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (Partnership with government for (BuiCding Safety DATE: April 12, 2013 JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 13-0627 SET II PROJECT ADDRESS: 1 Legoland Dr. PROJECT NAME: Legoland Upper Deck Restaurant TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I ] The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I ] The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. A] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. The applicant's copy of the check list has been sent to: SMS Architects (Gerald Michaeles) I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted: Gerald Michaels Telephone #: 949-757-3240 Date contacted: HI^ I-(i>, {by. ^) Email: qerald(%SMS-Arch.com Fax #: MailTelephone Fax In Person • REMARKS: By: Glen Adamek Enclosures: EsGil Corporation GA • EJ • PC 4/4/2013 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 13-0627 April 12, 2013 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. THE NOTES IN BOLD FONT ARE CURRENT REMAINING ITEMS. A) Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. B) To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C) Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? • Yes • No 1. There are no architectural/structural corrections required. Please see below for MEP items. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Glen Adamek at Esgil Corporation. Thank you. ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: Eric Jensen ELECTRICAL (2010 CALIFORNIA ELECTRICAL CODE) The electrical plans substantially comply with the jurisdiction's electrical codes. Carlsbad 13-0627 April 12, 2013 PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek GENERAL AND ARCHITECTURAL PME ITEMS 1. The new sheet P5.1 is not signed and sealed. Also, there is no State License for an interior designer. The kitchen drawings must be signed by a State Licensed Contractor work he is doing or a State Licensed Engineer or a State Licensed Architect. The kitchen drawings are not signed and the designer's name & State license number are not shown. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. 2. The City Building Official to review evidence of Health Department approval for proposed changes in the restaurant. PLUMBING (2010 CALIFORNIA PLUMBING CODE) 4-7 The gas line calculations for low pressure gas systems on sheets P0.1 and P5.1 do not agree. And the gas line plans on sheet P0.1 and sheet P2.1 do not seem to agree and can not be corrected without the corrected gas line sizing: Please provide cut-sheets and installation instructions for the proposed three deck Pizza Oven. Is this three stacked ovens or is this a single three level oven? Checking the gas connections. (Cut-sheets clearly show three separate ovens with each having gas demands of 1,100 CFH.) A) The developed gas pipe lengths do not agree. B) The Pizza Oven Gas demands do not agree. C) The Pizza Ovens require three gas line sediment traps, one for each oven. See the attached detail to the correct layout. D) Correct the new PVC pipe sleeve for the under ground gas line to show the required vent to the exterior for the PVC pipe sleeve. E) A complete review ofthe gas line sizing calculations and gas line plans will be done when corrected plans and calculations are provided. 8. On sheet P0.1 please correct the total developed gas pipe length for the 5 psi gas system from the public gas meter to the gas pressure regulator for this building. Not 120 feet shown to be just from the 5 psi loop to the gas pressure regulator for this building. Also the inside diameter ofthe VA inch PE pipe is not 1.494 inches as in the high pressure gas line sizing equation. As per the data provided the inside diameter ofthe VA inch PE pipe is only 1.328 inches. This is the outside pipe diameter minus two time the wall thickness (1.66-{0.133+0.133}). Please provide gas line sizing calculations for the 5 psi gas line from the public gas meter to the gas pressure regulators at this building. Clearly show the developed gas pipe length used. Carlsbad 13-0627 April 12, 2013 MECHANICAL (2010 CALIFORNIA MECHANICAL CODE) 9. Sheets K-6 & K-7 does not address the interior volume ofthe boxes and the amount and types of refrigerants, to show compliance with UMC, Section 1105.3. Sheets K-6 & K-7 seem to show new or remodeled walk-in cooler and walk-in freezer boxes. Please provide calculations to show compliance with UMC, Section 1105.3 for the maximum allowed amount of refrigerant in the walk-in coolers and walk-in freezer boxes as per UMC, Table 11-1 or please provide the required refrigerant vapor detection and alarm systems. 10. Please provide complete plans and calculations provided for all three kitchen hood systems, (for the new Dishwasher Hood system, the new Pizza Oven Hood system and the existing type I hood system over the new 2- Pasta Cookers & new Chinese Range and the existing cook line with 2-Cheeze Melters, Griddle, Range & Char- Broiler) Note the interior designer is not licensed to do the mechanical designs for the proposed kitchen hood systems. Please correct. Please provide complete kitchen hood plans, details, and calculations for the new Dishwasher Hood system, the new Pizza Oven Hood system and the existing type I hood system over the new 2- Pasta Cookers & new Chinese Range and the existing cook line with 2-Cheeze Melters, Griddle, Range & Char-Broiler, to show compliance with CMC, Chapter 5, Part II Note, the mechanical plans do not include the kitchen hood svstem designs details and calculations. a) Provide exhaust sizing calculations for kitchen hoods CMC 508.4 b) Show the required replacement air for each kitchen hood. Include an air balance schedule. CMC 511.3 c) Show the required replacement air for each kitchen hood. Include an air balance schedule. UMC 511.3 Please correct and provide calculations to show replacement air quantity shall be adequate to prevent negative pressures in the commercial cooking areas from exceeding 0.02 inch of water column. d) Clearly show the matenal used to construct the hood and exhaust duct. CMC Section 508.1.1 e) A fire damper is required at the connection of the supply air outlet to the shell of the hood assembly. Include the damper location and access panel required on the plans. CMC 508.5 & 510.3 f) Provide grease duct air velocity calculations. (Minimum 500 fpm. Maximum 2,500 fpm) CMC 511.2. g) Provide a section detail for the hood showing the relative dimensioned locations for the hood, ceiling, and overhead construction framing of the floor or ceiling . Be sure to describe the construction materials (combustible, limited combustible, or non-combustible) used adjacent to the hood and duct. CMC 507.2 h) Provide construction details for the fire rated grease duct enclosure. Note: Clearance distances from the grease duct to the enclosure inside face is not less than 6" (non-combustible) and 18" (combustible). CMC Sections 510.7 & 510.7.2.3. Carlsbad 13-0627 April 12, 2013 i) A single story non-rated building does not require an enclosure (shaft) protection for the grease duct installation above the ceiling. It does, however, mandate minimum clearance distances from the duct to combustible, limited, or non- combustible materials. Detail compliance with CMC 507.2 on the plans. j) A duct shaft is required in all multistory buildings and in 1 story buildings with rated roof/ceiling assemblies. Provide a shaft design complying with CMC 510.7.2 and 510.7.3 on the plans. k) Detail the slope (1/4"/foot/minimum) on the horizontal grease duct back towards the hood. CMC 510.1.4. I) Show the required cleanouts for the grease duct: i) At changes in direction and ii) If the duct is not accessible from a 10' stepladder, a platform is required. Please detail. CMC 510.3.4.1.2 m) Detail the kitchen hood duct termination clearances as per CMC 510.8. n) A complete kitchen hood system plan review will be done when the complete hood system plans, details, and calculations are provided. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 13-0627 April 12, 2013 To Gas supply inlet -Tee firtPng Nipple Cap-#-r 3 in. (80 mm) minimum ± FiGURE 12-1 METHOD OF IMSTALLING A TEE FITTING SEDI- MENT TRAP. SUBJECT Upper Deck - Legoland REVIEWED 8Y Glen Adamek, Eric Jensen JURISDICTION Carlsbad ADDRESS: 1 Legoland Dr DATE OF PLAN CHECK 4/12/13 DATE RESPONDED 4/24/13 exp PROJECT NUMBER- 2013027 PLAN CHECK NUMBER- 13-0627 exQ Sheet Number | Issue | Comment [Response PLUMBING P5.1 (New) The new sheet P5 1 is not signed and sealed. Also, there IS no State License for an interior designer. The kitchen drawings must be signed by a State Licensed Contractor work he is doing or a State Licensed engineer or a State Licensed Architect RJones/exp, Complied added MEOR seal & signature Ptoaao provide cut chooto and inatallation inctructiona for N/A tho propoBod throo dock Pisia Ovon Is this three stacked ovens or is this a single three level oven'' Checking Ihe gas connections RJones/exp, Complied, see attached The pizza oven consists of three stacked ovens, refer lo manufacturers cut-sheet Note Mfr data sheet indicates 110 MBH per pizza oven Mfr installation instructions indicates meter sizing based on 450 MBH for 1 to2 ovens & additional 180 MBH ea additional oven Higher MBH value does not affect regulated main size, however did increase regulator size from 1 1/4" to 1 1/2" 4-7 P0.1 and P5.1 & PO 1 and P2.1 (New) The gas line calculations for low pressure gas systems on sheets PO 1 and P5 1 do not agree And the gas line plans on sheet PO 1 and sheet P2 1 do not seem to agree and can not be corrected without the corrected gas line sizing (Cut-sheets clearly show three separate ovens with each having gas demands of 1,100 CFH) A) The developed gas pipe lengths do not agree. B) The Pizza Oven Gas demands do not agree. C) The Pizza Ovens require three gas line sediment traps, one for each oven See the attached detail to the correct layout D) Correct the new PVC pipe sleeve for the under ground gas line to show the required vent to fhe exterior for the PVC pipe sleeve. E) A complete review of the gas line sizing calculations and gas line plans will be done when corrected plans and calculations are provided RJones/exp, Complied, sheet P5 1 , deleted gas line calculation on the sheet moved details 5 & 6 from sheet PO 1 to this sheet & added Gas Pipe Sediment Trap & new Gas Fired Water Heater Included additional piping sizes on P2 1 to match what is indicated on sheet PO 1 Manufacturers cut-sheets indicates 110 CFH (110,000 Btuh/IOOOBtuh per CFH) input for each oven. SHEET PO 1 A) - (E) Bldg Supply Lateral, Added TDL calculation to pipe sizing & piping diagram and 850 ft maximum length to pipe sizing table A) - Regulated Mam, Pipe sizing table TDL (144 ft) is system length, maximum length (150 ft) on pipe sizing table is based on CPC table 12-8 row for 150 ft B) - Revised gas load analysis to indicate 110,000 Btuh & piping diagram to indicate 110 CFH for ea pizza oven. C) - Revised piping diagram to match figure 12-1 D) - Revised piping diagram to include 1 -inch pipe sleeve relief vent, see also sheet P2 1 Key Note 10 E) - Corrected plans and calculations provided with BC II responses. SHEET PO 1 - NEW 1 Deleted existing 199 MBH water heater & replaced with new 250 MBH water heater revised gas calculations & diagram to reflect increased gas load 2 Added Water Heater & Fixture Connection Schedule SHEET P1 1 - NEW 1 Removed existing 199 MBH, 100 gallon water heater & replace with new 250 MBH 100 gallon water heater SHEET P2 1 - NEW 1 Added new gas fired 250 MBH, 100 gallon water heater at existing water heater location, same diameter as existing 199 MBH heater 2 Added new hand wash sink rough-in in kitchen adiacent to new pizza oven. PO 1 Ploaso cloariy ohow tho propoeod gas piping matonal Gas lino oimng catoukitions provided aro for cchodulo W RJonoo/oxp, Complied, coo Pro/oct Notoe "Matonale" Itom 6 & eheot PO 3 spec aoction 237000 Puol Gas Piping coction 2 1 A&B iron oiDina- PO 1 AG per the gas line sizing calculations provided tho .IH inch gas lino to each of tho throo ooparato ovon dooks le RJonoe/exp, Concur, revised pipe owe por pipe sizing table Soo gas piping diagram undersizod- PO 1 As per the gas line sizing calculations provided the gas lines from the gas pressure regulators to the 3 inch building gas mam are undersized RJones/exp, Concur, revised detail 6 & plumbing renovation plan sheet P2 1 to show 3" header PO 1 MECHANICAL Please provide gas line sizing calculations for the 5 psi gas line from the public gas meter to the gas pressure regulators at this building Clearly show the developed gas pipe length used Sheets K-6 & K-7 seem to show new or remodeled walk- in cooler and walk-in freezer boxes Please provide calculations to show compliance with UMC, Section 1105 3 for the maximum allowed amount of refrigerant in the walk-in coolers and walk-in freezer boxes as per UMC, Table 11 -1 or please provide the required refrigerant vapor detection and alann systems RJones/exp, Complied, see attached Note Building is sen/ed from metered loop, see detail 4 Existing Natural Gas Distnbution Plan Total developed length based on 1 1/4" branch mam off of loop Pipe Size Table (E)5PSI Bldg Supply Lateral 1 1/4" Line Capacity based on MG PE Pipe Calc, "(8)1 1/4" Building Supply Lateral (5 0 PSI) - Max SCFH Capacity" See Kitchen Consultant review comments H-(20130Zr {J01OWGS'J^OTS12013 CM 23 BflCKCHECK #2teKp-PC Responsa 10 Please provide complete plans and calculations provided for all three kitchen hood systems For the new Dishwasher Hood system, the new Pizza Oven Hood system and the existing type 1 hood system over the new 2- Pasta Cookers & new Chinese Range and the existing cook line with 2-Cheeze Melters, Gnddle, Range & Char- Broiller Note the interior designer is not licensed to do the mechanical designs for the proposed kitchen hood systems Please correct There are 3 kitchen hoods, however the dishwasher is not one of them 1 hood is new 1 hood has kitchen equipment changing below it but is not changing and the third hood IS not in the scope of this project 10(a) Provide exhaust sizing calculations for kitchen hoods CMC 508 4 See Kitchen Consultant review comments MO 2 10(b) Show the required replacement air for each kitchen hood Include an air balance schedule CMC 511 3 An air balance schedule has been added as well as a kitchen exhaust table that shows all replacement airflows MO 2, Ml 1 10(c) Show the required replacement air for each kitchen hood Include an air balance schedule UMC 511 3 Please correct and provide calculations to show replacement air quantity shall be adequate to prevent negative pressures in the commercial cooking areas from exceeding 0 02 inch nf water column. See air balance schedule added to sheet MO 2 The kitchen area is open to the dining room Added makeup air has been provided to balance added exhaust hood, therefore there has been no change to the overall air balance of the space There is no transfer air from exterior or nearby spaces that would cause the kitchen space to be negative pressure M5 1 10(d) Clearly show the material used to construct the hood and exhaust duct CMC Section 508 1 1 Note added to detail 5 on sheet M5 1 for the grease exhaust duct to be constructed of at least 0 055 inch thick steel or 0 044 inch thick stainless steel The hood material is listed on sheets K-10 1 and K-10 2 As-built drawing detail has been added to plans for (E) hood to be re-used Construction is detailed in that location M5 1 10(e) A fire damper is required at the connection of the supply air outlet to the shell of the hood assembly Include the damper location and access panel required on the plans CMC 508 5 & 510 3 The new hood does not have built-in supply air so no dampers are required for this hood Damper location shown on (E) hood detail M5 1 10(f) Provide grease duct air velocity calculations (Minimum 500 fpm, Maximum 2,500 fpm) CMC 511 2 Grease duct velocity and calculations added to detail 5 and 14 on sheet M5 1 M5 1 10(g) Provide a section detail for the hood showing the relative dimensioned locations for the hood, ceiling, and overhead construction framing of the floor or ceiling Be sure to describe the construction matenals (combustible, limited combustible, or non-combustible) used adjacent to the hood and duct CMC 507 2 Dimensions showing floor to ceiling, floor to hood, and height of kitchen equipment added to detail 5 on sheet M5 1 See Kitchen Consultant sheets K-10 1 and K-10 2 showing the minimum hood overhang As-built detail of (E) hood added with construction details and dimensions M5 1 10(h) Provide construction details for the fire rated grease duct enclosure Note Clearance distances from the grease duct to the enclosure inside face is not less than 6" (non- combustible) and 18" (combustible) CMC Sections 510 7 & 510.7.2.3. 2-hr fire rated duct wrap to be provided for new grease exhaust duct See detail 13 on sheet M5 1 Detail provided for (E) hood to be re-used Detail shows shaft enclosure M5 1 10(1) A single story non-rated building does not require an enclosure (shaft) protection for the grease duct installation above the ceiling It does, however, mandate minimum clearance distances from the duetto combustible, limited, or noncombustiblematerials Detail compliance with CMC 507 2 on the plans Fire rated shaft enclosure removed and replaced with a 2-hr fire rated duct wrap Detail provided for (E) hood to be re-used M5 1 10(1) A duct shaft IS required in all multistory buildings and in 1 story buildings with rated roof/ceiling assemblies Provide a shaft design complying with CMC 510 7 2 and 510 7 3 on the Dians 2-hr fire rated duct wrap to be used for new grease exhaust duct (E) shaft shown on detail for hood to be re-used M2 1, M5 1 10(k) Detail the slope (1/47foot/minimum) on the horizontal arease duct back towards the hood CMC 510 1 4 See note added to sheet M2 1 and to detail 10 on sheet M5 1 M2 1 10(1) Show the required cleanouts for the grease duct (i) At changes in direction and (ii) If the duct is not accessible from a 10' stepladder, a platform is required Please detail. CMC510 34 1 2 (i) Grease clean-out access panel added at change of direction on sheet M2 1 (ii) Duct IS accessible. (E) hood is straight shot up to fan, no cleanouts required in ductwork M5 1 10(m) Detail the kitchen hood duct termination clearances as per CMC 510 8 The exhaust is being directed up and away from the surface of the roof at a minimum of 40 inches above the roof surface per detail 10 and 14 on sheet M5 1 OTHER MECHA^ MD1 1,M1 1 Ml 1 M2.1 M5 1 ELECTRICAL E0.1 10(n) ICALS N/A A complete kitchen hood system plan review will be done when the complete hood system plans, details, and calculations are provided MEET CHANGES A change that has been made to the sheet that is not a result of corrections from the list Noted Viewport expanded to show systems referred to in air balance table Duct transition changed to (E) EF-7 riser (E) exhaust vent from bathroom shown on roof plan dishwasher ductwork modified. A disconnect has been added to sheet E2.1 and the proper mounting height is shown on the electncal lead sheet H->20I3OT7 (XW3WGS^PLOTS^2013 04 23 BACKCHECK K-^ip-PC RosponsojtlSK E2 1 N/A A change that has been made to the sheet that is not a result of corrections from the list Due to the addition of a booster heater, a junction box and disconnect have been added to accommodate the new equipment power requirements Also, we have coordinated more equipment under the pizza/pasta server/ with the kitchen consultant E6 1 N/A A change that has been made to the sheet that is not a result of corrections from the list Panel Schedules have been updated to reflect the loads of additional equipment H-12013027 OOOWGSVPLOTSaOl 3 04 23 BACKCHECK lt2\exp-PC Rosponso xlsx K 4' ^ t «J HATCH DtSlCJN GROUP Date: Company: Adciress: Phone #: Attention: TRANSMITTAL 04-23-2012 Project Name: Legoland California Pizza & Pasta Buffet Project Location: One Legoland Drive, Carlbad, CA 92008 Sent Via: Sent By: CC: Bruce Brandey We are transmitting: 1. Remarks: The following is an itemized response for plan check corrections: Mechanical 10. Sheets K-10.1 and K-10.2 indicate the hood information for the old and new hoods. The dishwasher assembly includes vent cowls (small hoods) built-in. Attached is the cut-sheet. 10a. All of the exhaust hoods are U.L. listed so they are exempt for sizing calculation. They are engineered per the manufacturer's listing. lOd. The hood material is listed on sheets K-10.1 & K10.2. 1 Oe. The supply air dampers for the existing hood assembly are shown on sheet K-10.2. The new hood doesn't have built-in supply air so no dampers are required for this hood. Hatch Design Group 3198-G Airport Loop Dnve Costa Mesa, CA 92626 (714) 979-8385 Phone (714) 979-6430 Fax www.hatchdesiqn.com Page 1 1 Og. K-10.1 and K-10.2 show the min. hood overhang. Pluming and Mechanical 1. Added stamp and signature to titleblock. 4. Provided cut-sheets. 9. Indicated refrigerant leak detector on new cooler. lOd. Indicated hood gauge thickness. Fire Revised sheets K-7, K-8 and K-9. Hatch Design Group 3198-G Airport Loop Drive Costa Mesa, CA 92626 (714) 979-8385 Photie (714) 979-6430 Fax www.hatchdesiqn.com Page 2 EsGii Corporation In (Partnership with government for (BuiCding Safety DATE: March 26, 2013 •APPLICANT Jgf JURIS JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 13-0627 SET I PROJECT ADDRESS: 1 Legoland Dr. PROJECT NAME: Legoland Upper Deck Restaurant TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: SMS Architects (Gerald Michaels) I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. [XI EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Gerald Michaels Telephone #: 949-757-3240 Date contacted: (by: ) Email: gerald@SMS-Arch.com Fax #: Mail Telephone Fax In Person • REMARKS: By: Kurt Culver Enclosures; EsGil Corporation KI GA KI EJ • PC 3/18/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 13-0627 March 26, 2013 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 13-0627 PROJECT ADDRESS: 1 Legoland Dr. DATE PLAN RECEIVED BY ESGIL CORPORATION: 3/18/13 DATE REVIEW COMPLETED: March 26, 2013 REVIEWED BY: Kurt Culver FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? • Yes • No Carlsbad 13-0627 March 26, 2013 1. There are no architectural/structural corrections required. Please see below for MEP items. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kurt Culver at Esgil Corporation. Thank you. ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: Eric Jensen ELECTRICAL (2010 CALIFORNIA ELECTRICAL CODE) 1. Please provide a GFI/WP outlet within 25' of the two condensing units on roof. CEC 210 63 2. Two mechanical units on the roof (item 1 above) are not included on the mechanical plans. At any rate verify power requirements. Note: If you have any questions regarding this Electrical and Energy plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. PLUMBING AND MECHANICAL CORRECTIONS PLAN REVIEWER: Glen Adamek GENERAL AND ARCHITECTURAL PME ITEMS The kitchen drawings are not signed and the designer's name & State license number are not shown. Each sheet ofthe plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. The City Building Official to review evidence of Health Department approval for proposed changes in the restaurant. Carlsbad 13-0627 March 26, 2013 3. For clearances around new or existing units to be relocated to the edge of the roof to be 10 feet maximum or provide 42 inch tall guard rails. Please correct the drawings to show the required 42 inch tall "Guards" (guard rails) as per CBC, Section 1013.5: "Where appliances, equipment, fans, roof hatch openings or other components that require service are located within 10 feet of a roof edge or open side of a walking surface..." PLUMBING (2010 CALIFORNIA PLUMBING CODE) 4. Please provide cut-sheets and installation instructions for the proposed three deck Pizza Oven. Is this three stacked ovens or is this a single three level oven? Checking the gas connections. 5. Please clearly show the proposed gas piping material. Gas line sizing calculations provided are for schedule 40 iron piping. 6. As per the gas line sizing calculations provided the % inch gas line to each of the three separate oven decks is undersized. 7. As per the gas line sizing calculations provided the gas lines from the gas pressure regulators to the 3 inch building gas main are undersized. 8. Please provide gas line sizing calculations for the 5 psi gas line from the public gas meter to the gas pressure regulators at this building. Clearly show the developed gas pipe length used. MECHANICAL (2010 CALIFORNIA MECHANICAL CODE) 9. Sheets K-6 & K-7 seem to show new or remodeled walk-in cooler and walk-in freezer boxes. Please provide calculations to show compliance with UMC, Section 1105.3 for the maximum allowed amount of refrigerant in the walk-in coolers and walk-in freezer boxes as per UMC, Table 11-1 or please provide the required refrigerant vapor detection and alarm systems. 10. Please provide complete kitchen hood plans, details, and calculations for the new Dishwasher Hood system, the new Pizza Oven Hood system and the existing type I hood system over the new 2- Pasta Cookers & new Chinese Range and the existing cook line with 2-Cheeze Melters, Griddle, Range & Char-Broiller, to show compliance with CMC, Chapter 5, Part II Note, the mechanical plans do not include the kitchen hood svstem designs details and calculations. a) Provide exhaust sizing calculations for kitchen hoods. CMC 508.4 b) Show the required replacement air for each kitchen hood. Include an air balance schedule. CMC 511.3 c) Show the required replacement air for each kitchen hood. Include an air balance schedule. UMC 511.3 Please correct and provide calculations to show replacement air quantity shall be adequate to prevent negative pressures in the commercial cooking areas from exceeding 0.02 inch of water column. d) Clearly show the material used to construct the hood and exhaust duct. CMC Section 508.1.1 Carlsbad 13-0627 March 26, 2013 e) A fire damper is required at the connection of the supply air outlet to the shell of the hood assembly. Include the damper location and access panel required on the plans. CMC 508.5 & 510.3 f) Provide grease duct air velocity calculations. (Minimum 500 fpm. Maximum 2,500 fpm) CMC 511.2. g) Provide a section detail for the hood showing the relative dimensioned locations for the hood, ceiling, and overhead construction framing of the floor or ceiling . Be sure to describe the construction materials (combustible, limited combustible, or non-combustible) used adjacent to the hood and duct. CMC 507.2 h) Provide construction details for the fire rated grease duct enclosure. Note: Clearance distances from the grease duct to the enclosure inside face is not less than 6" (non-combustible) and 18" (combustible). CMC Sections 510.7 & 510.7.2.3. i) A single story non-rated building does not require an enclosure (shaft) protection for the grease duct installation above the ceiling. It does, however, mandate minimum clearance distances from the duct to combustible, limited, or non- combustible materials. Detail compliance with CMC 507.2 on the plans. j) A duct shaft is required in all multistory buildings and in 1 story buildings with rated roof/ceiling assemblies. Provide a shaft design complying with CMC 510.7.2 and 510.7.3 on the plans. k) Detail the slope (1/4"/foot/minimum) on the horizontal grease duct back towards the hood. CMC 510.1.4. I) Show the required cleanouts for the grease duct: i) At changes in direction and ii) If the duct is not accessible from a 10' stepladder, a platform is required. Please detail. CMC 510.3.4.1.2 m) Detail the kitchen hood duct termination clearances as per CMC 510.8. n) A complete kitchen hood system plan review will be done when the complete hood system plans, details, and calculations are provided. Note: If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 13-0627 March 26, 2013 [DO NOT PAY- THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 13-0627 PREPARED BY: Kurt Culver DATE: March 26, 2013 BUILDING ADDRESS: 1 Legoland Dr. BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING PORTION AREA (Sq Ft.) Valuation Multiplier Reg Mod VALUE ($) Tl 318,148 Air Conditioning Fire Sprinklers TOTAL VALUE 318,148 Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review • Repetitive Fee Repeats • Complete Review • Other ^ Hourly EsGil Fee • Structural Only Hr @ $1,554.10 $1,010.17 $870.30 Comments- Sheet 1 of 1 macvalue doc + z^ mh. PLAN CHECK Community & Economic <^W77 CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 www carlsbadca.gov DATE: 03/18/13 PROJECT NAME: LEGOLAND UPPER DECK RESTAURANT PLAN CHECK NO: 1 SET#: 1 ADDRESS: 1 LEGOLAND DR VALUATION:^318,148 PROJECT ID: CB13 627 APN: 211-100-09 s / i This plan chectH\eview is complete and has been APPROVED by the ENGINEERING I i Division. Final Inspection by the Division is required LJYes L/JNO r\71 This plan check review is NOT COMPLETE. Items missing or incorrect are listed on [Azz the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: You may also have corrections from one or more of the divisions Usted below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-46i0 ENGINEERING 760-602-2750 . ^ FIRE PREVENTION . 760.602-4665 • - 1 1 Chris Sexton ! > 760-602-4624 Chris.Sexton@carlsbadca.fiov |T/1 Kathleen Lawrence LV^J 760-602-2741 Kathleen.Lawrence@carlsbadca.gov i Greg Ryan J 760-602-4663 Gregorv.Rvan@carlsbadca.gov Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov r~l Linda Ontiveros 1—J 760-602-2773 Linda.Ontiveros@carlsbadca.gov 1 Cindy Wong ' 760-602-4662 Cvnthia.Wong@carlsbadca.gov 1 , r 1 Dominic Fieri L 1 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: Set# Any outstanding issues will be marked with | X] . Make the necessary corrections for compliance with applicable codes and standards. Submit corrected plans and/or specifications to the Building division for re-submittal to the Engineering_division. Items that conform to permit requirements are marked withl / ] 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show, LZJ CZD North arrow Existing & proposed structures Existing street improvements Property lines (show all dimensions) • cz: J Easements CZZ] CZU Right-of-way width & adjacent streets {__} Driveway widths CZH Existing or proposed sewer lateral CZZ] Existing or proposed water service CZZJ Submit on signed approved plans DWG No Show on site plan: • • / 1 Drainage patterns Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course [ JADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". I I Existing & proposed slopes and topography JSize, location, alignment of existing or proposed sewer and water service(s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. ] Sewer and water laterals should not be located within proposed dnveways, per standards Include on title sheet: / Site address [y~2 Assessor's parcel number {AZ] Legal description/lot number For commercial/industnal buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufactunng, warehouse, office, etc ) previously approved r j Show all existing use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/Map No. N/A Subdivision/Tract Reference No(s) E-36 Page 2 of 6 REV 6/01/12 Set# 1 2. DISCRETIONARY APPROVAL COMPLIANCE N/A ZZ2 Project does not comply with the following engineering conditions of approval for project no 3. DEDICATION REQUIREMENTS N/A [" I Dedication for all street rights-of-way adjacent to the building site and any storm dram or utility easements on the building site is required for ail new buildings and for remodels with a value at or exceeding $ 20.000.00 , pursuant to Carlsbad Municipal Code Section 18 40.030. For single family residence, easement dedication will be completed by the City of Carlsbad, cost $605.00. Dedication required as follows 4. IMPROVEMENT REQUIREMENTS N/A All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $100.000.00. pursuant to Carlsbad Municipal Code Section 18.40 040 Public improvements required as follows [ I Construction of the public improvements must be deferred pursuant to Carlsbad Municipal Code Section 18.40 Please submit a recent property title report or current grant deed on the property and processing fee of $ 458.00 so we may prepare the necessary Neighborhood Improvement Agreement This agreement must be signed, notarized and approved by the city prior to issuance of a building permit. \AZ} Future public improvements required as follows E-36 Page 3 of 6 Set# 1 5- GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. ZZ. "jlnadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial) This information must be included on the plans. If no grading is proposed write: "NO GRADING" I Grading Permit required. NOTE" The grading permit must be issued and rough grading approval obtained prior to issuance of a building permit I Graded Pad Certification required. (Note Pad certification may be required even if a grading permit is not required) All required documentation must be provided to your Engineenng Construction Inspector The inspector will then provide the engineenng counter with a release for the building permit. j7_J No grading permit required. i Minor Grading Permit required. See attached marked-up submittal checklist for project- specific requirements. 6. MISCELLANEOUS PERMITS r~1 RIGHT-OF-WAY PERIVIIT is required to do work in city nght-of-way and/or pnvate work ~~~~ adjacent to the public right-of-way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm dram, sewer and water utilities j Right-of-way permit required for E-36 Page 4 of 6 REV 6/01/12 Set# 1 7. STORMWATER Construction Compliance INTERIOR REMODEL OF RESTAURANT [•——I \AL} Project Threat Assessment Form complete [__ j Enclosed Project Threat Assessment Form incomplete. A3 Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form and return (SW ) LTII Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Development (SUSMP) Compliance r ~] Storm Water Standards Questionnaire complete. • Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign the questionnaire and resubmit with next submittal 1 Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. http //www carlsbadca qov/business/buildinq/Documents/EnqStandsw-stds-vol4-ch2 pdf 1 Project needs to incorporate low impact development strategies throughout in one or more of the following ways 1731 Rainwater harvesting (rain barrels or cistern) L] Vegetated Roof AZ Bio-retentions cell/ram garden cm Pervious pavement/pavers iZ2 Flow-through planter/vegetated or rock drip Ime ["21 Vegetated swales or rock infiltration swales LJ Downspouts disconnect and discharge over landscape • Other E-36 Page 5 of 6 REV 6/01/12 Set# 1 9. WATER METER REVIEW Domestic (potable) Use AZi What size meter is required"? [IYD Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size shall be a 1" meter. NOTE- the connection fee, SDCWA system capacity charge and the water treatment capacity charge will be based on the size of the meter necessary to meet the water use requirements WW} For residential units the minimum size meter shall be 5/8", except where the residential unit is larger than 3,500 square feet or on a lot larger than one quarter (1/4) acre where the meter size shall be YZ. 8. FEES 1 i • yes • no Required fees have been entered m building permit. Drainage fee applicable Added square feet Added square footage m last two years'? Permit No Permit No. Project built after 1980 Impervious surface > 50% Impact unconstructed facility Fire spnnklers required [jyes [Zlf^o (is addition over 150' from centeriine) Upgrade T] yes Qno No fees required •yes • yes IA° • no 10. Additioriaf Comments Will there be any additional seating added to the remodel of the Upper Deck restaurant inside Legoland? If yes, number of existing and number of new proposed seating. Thank you. Kathleen 760-602-2741 Eng. Counter I LlTui UruiZ 6^ )S^Z^ TZULCM ZA^-^f\J~^ Attachments: • ; Engineering Application E-36 Storm Water Form i. ) Right-of-Way Application/lnfo. Page 6 of 6 Reference Documents ca REV 6/01/12 4 CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www carlsbadca eov DATE: 3/18/13 PROJECT NAME: T.l. PROJECTID: PLAN CHECK NO: CB130627 SET#: ADDRESS: 1 LEGOLAND DR APN: ^ This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required • Yes ^ No You may also have corrections from one or more ofthe divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. • This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: GERALD@SIVlS-ARCH.COIVI For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.fiov 1 Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.fiov 1 I Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.fiov 1 Cindy Wong 760-602-4662 Cvnthla.Wonfi@carlsbadca.gov • • 1 1 Dominic Fieri 760-602-4664 Dominic.Fien@carlsbadca.gov Remarks: CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL G jg^mmunity & Economic Iv^lopment Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 4/23/13 PROJECT NAME: Upper Deck PROJECTID: PLAN CHECK NO: cbl30627 SET#: I ADDRESS: 1 legoland dr APN: • This plan check review Is complete and has been APPROVED by the fire Division. By: cwong A Final Inspection by the Division is required ^ Yes • No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.£ov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov 1 1 Greg Ryan 760-602-4663 Gregory.Ryan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov X Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov • • 1 1 Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: **APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. Page 1 of 2 THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Page 2 of2 Carlsbad Fire Department Plan Review Requirements Category: TI, COMM Date of Report: 04-23-2013 Reviewed by •./Ao Name: Address: GERALD MICHAELS STE.B 17848 SKY PARKCR. IRVINE CA 92614 Permit #: CBI30627 Job Name: LEGOLAND: 6,325 SF TI TO EXIST Job Address: 1 LEGOLAND DR CBAD JtNeOMPrETE"" The iteiri"\r6u"lia^^g'^gbTyfitt€d-€^ office camiot adequately conduct a review to determinejgjBpli^-e?''Wiffi^^ap . Please review carefully all comments att^^sd^^f'lfaseresubmit the necessary plans and/or specifications^wi^ttiwiges "clouded", to this office forrejji©^#^dapproval. Conditions; Cond: CON0006256 [MET] ** APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 04/23/2013 By: cwong Action: AP BLDG. DEPT COPY CORRECTION LIST RECOMMlMAtJMFC^^ Page: 1 of 6 Daryl K. James & Associates, Inc. Re-Checked By: Robert Salqado Plan Check Date: 04/10/2013 APPLICANT: Gerald Michaels, Primary Applicant SMS Architects, (949) 757-3240; email gerald@sms-arch com JURISDICTION: Carlsbad Fire Department, Fire Prevention PROJECT NAME: Legoland Restaurant T I PROJECT ADDRESS: 1 Legoland Dr., Carlsbad, CA 92008 PROJECT DESCRIPTION: CB130627 - The Legoland Upper Deck Restaurant T.l. project involves demo and renovation work within an existing restaurant, all work is restncted to a total area of 6,325 S.F , including existing outdoor patio areas The scope of work in the A and B occupancies includes the following: New pizza oven and new type I hood, stock to walk-in chiller, buffefserving station remodel, new finish work in the dining area, and new mechanical, electrical, and plumbing (MEP) Modifications to existing fire alarm and sprinkler systems and new fire protection systems for protecting commercial cooking equipment will be submitted separately as deferred submittal items This plan review has been conducted in order to venfy conformance to minimum requirements of codes adopted by the Carlsbad Fire Department applicable to the scope of work The Items below require correction, clarification or additional information before this plan check can be approved for permit issuance RESUBMITTAL INSTRUCTIONS TO AVOID DELAY IN EXPEDITED RECHECK SERVIGES: 1. Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates. 2. Provide a written response following each comment, On This Correction List, explaining how and where you've addressed each plan review comment. 3. Provide a copy of Building Department (EsGil) comments. Input fire revisions onto the Building Dept. plan check. 4. Please direct any questions regarding this review directly to: Robert Salgado at: (951) 541- 4380, or to his email address at: fisreview inspection@roadrunner.com iCOMMENTS MUST BE SUBMITTED DIREGTLY^TO THE FOLLOWINGiADDRESS; JO AVOID DELAY: Attn: Robert Salgado 36341 Flower Basket Road Winchester, CA 92596 FIRE PROTECTION SYSTEM PLAN REVIEW: • AO.l. GENERAL NOTES AND SHEET INDEX: 1) •Update the information under the sub-heading "DEFERRED SUBMITTALS" on Sheet AO 1 and insert the following text Deferred Submittal Items. a Fully-Automatic Fire Spnnkler System, California 2010 Fire Code, Section 903, and NFPA 13, 2010 edition Architect of record (AOR) to consult with the city of Carlsbad Fire Marshal for design criteria (hazard class/density) required for all uses and occupancy groups associated with this project b Fire Alarm and Detection System, 2010 CFC, Sections 907 1 through 907 9 (which includes all other uses and occupancy groups associated with this project), and NFPA 72, 2010 edition Specify type of system Manual or automatic, combination automatic/manual alarm and detection system, and specify spnnkler monitonng requirements in accordance with 2010 CFC, 903 4 through 903 4 2 c Protection of Commercial Cooking Systems, 2010 CFC, Section 904 11 [Specify the type of automatic extinguishing system(s) that the owner plans to install in the kitchen] NOTE All existing dry chemical and wet chemical extinguishing systems shall comply with UL 300 •AO.2. CODE SUMMARY AND EXITING: 1) •For construction type, clarify the meaning of "UNPROTECTED SPRINKLERED" as it applies to this project, are there any CBC substitutions utilized? 2) •Update the "CODE SUMMARY" to show the edition/year of amended model codes, and all NFPA Standards applicable, as listed below • 2010 California Building Code (CBC) Part 2, Volume 1 and 2, Title 24, California Code of Regulations (CCR) Based on the 2009 International Building Code (IBC) with 2010 Amendments • 2010 California Mechanical Code (CMC Part 4, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Mechanical Code (UMC) with 2010 Amendments • 2010 California Electrical Code (CEC Part 3, Title 24, California Code of Regulations (CCR) Based on the 2008 National Electncal Code (NEC) with 2010 Amendments • 2010 California Plumbing Code (CPC) Part 5, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Plumbing Code (UPC) with 2010 Amendments • 2010 California Fire Code (CFC) Part 9, Title 24, California Code of Regulations (CCR) Based on the 2009 International Fire Code (IFC) with 2010 Amendments NFPA STANDARDS • NFPA 13, Standard for the Installation of Spnnkler Systems • NFPA 17A, Wet Chemical Extinguishing Systems, 2002 Edition • NFPA 72, National Fire Alarm Code, 2010 Edition • NFPA 96, Ventilation Control and Fire Protection of Commercial Cooking Operations, 2008 Edition (incorporated by reference in the California Mechanical Code - Ch. 5, Part II) 3) •Update the "PROJECT DESRIPTION" to refiect a code analysis that defines separate allowable areas for the A and B occupancies (include all assembly rooms, kitchen spaces, and outdoor patio areas in the calculations). 4) •Two separate exits are required at both outdoor dining areas' Patio Dining #1 and Patio Dining #2 are not used for service of the building and individually house more than 100 occupants, therefore, the provisions of 2010 CBC, Sections 1004.8; 1015.2 1, and Table 1015.1 applies. Revise the floor plan and corresponding door schedule to show Panic Hardware at all exterior exit gates serving the outdoor patio areas. 5) •QUESTION: Are the outdoor patio areas covered? If yes, are they fully-spnnkled in accordance with the 2010 CFC and NFPA 13? 6) •QUESTION: Is the Architect of Record (AOR) proposing to use double-acting doors as part of the means of egress, as shown at both ends of the new Buffet? Please clarify the proposed exiting requirements from the kitchen, adjoining spaces, dishwashing room, prep area, servery, and along the path of travel to an exterior exit. 7) •Provide portable fire extinguishers for commercial cooking equipment, refer to 2010 CFC, Section 904 11.5 (Show symbol for Class K rating). •A2.1. FLOOR PLAN: 1) •Two separate exits are required at both outdoor dining areas' Patio Dining #1 and Patio Dining #2 are not used for service of the building and individually house more than 100 occupants; therefore, the provisions of 2010 CBC, Sections 1004.8; 1015 2.1; and Table 1015.1 applies. Revise the floor plan and corresponding door schedule to show Panic Hardware at all exterior exit gates serving the outdoor patio areas. 2) •Revise the floor plan and door schedule to show "Door Tags" with Letters and/or Numbers at each required exit door and exterior gates that serve more than 50 occupants whether the doors or gates are new or existing. The first column in the door schedule needs to show the door tag identification and the end column labeled "Remarks" must call-out the words "Panic Hardware." 3) •Clarify 1-hour separations (F.R construction) between the "A-3" and "B" occupancies The Floor Plan Notes, Key Notes, and Legends/Symbols on sheets AO.2 and A2.1 do not accurately reflect the requirements specified in 2010 CFC Table 508.4. NOTE. Exception d. only applies to the seating areas served by the kitchen, all other walls must be 1-hr; example: Restroom, janitor closets, etc. 4) •Update the door schedule to show a column marked "Hourly Rating" and identify which doors are required to be rated, example. 45 Mm, 60 Min, %-Hr, etc. • A2.3. ROOF PLAN: 1) •Specify the required Roof Covering Classification of any new built-up roof assemblies or repairs to the existing roof covenng, refer to 2010 CBC, Chapter 15. •A3.1. MISC. ELEVATIONS: 1) •Revise Detail 4/A3 1 to call-out 2-Hour construction on the exhaust shaft serving the hood and duct system Refer to Sheet MO 1 "Commercial Cooking Notes" 8 And 9 , and Sheet M5 1 Detail 5/M5 1 •A9.1. DETAILS: 1) •Specify the required Roof Covenng Classification of any new built-up roof assemblies (Curb Flashing or Equipment Platform), or repairs to the existing roof covenng, refer to 2010 CBC, Chapter 15 • K-7. REFRIGERATION DATA PLAN. 1) •Revise code references in the refrigeration notes to include the following • 2010 California Mechanical Code (CMC) Part 4, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Mechanical Code (UMC) with 2010 Amendments • 2010 California Electrical Code (CEC) Part 3, Title 24, California Code of Regulations (CCR) Based on the 2008 National Electrical Code (NEC) with 2010 Amendments • 2010 California Plumbing Code (CPC) Part 5, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Plumbing Code (UPC) with 2010 Amendments • 2010 California Fire Code (CFC) Part 9, Title 24, California Code of Regulations (CCR) Based on the 2009 International Fire Code (IFC) with 2010 Amendments 2) •Revise the refrigeration notes to incorporate the applicable provisions contained in the 2010 CFC, Section 606, only list those requirements that apply to cooler/freezer room • K-7. EXHAUST AND MAKE-UP AIR PLAN: 1) •Clarify the provisions 2010 CMC, Section 609 This provision applies to all air-moving systems (AHU's/HVAC Units) supplying air in excess of 2,000 CFM • K-9. GENERAL BUILDING DETAILS: 1) •Revise Details 5/K-9 and 6/K-9 to call-out 2-Hour construction on the exhaust shaft serving the hood and duct system Refer to Sheet MO 1 "Commercial Cooking Notes" 8 And 9 , and Sheet M5 1 Detail 5/M5 1 • M0.1. MECHANICAL LEAD SHEET: 1) •Add the following note to the "General Notes" box • All work shall be in accordance with the 2010 California Mechanical Code (CMC) Part 4, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Mechanical Code (UMC) with 2010 Amendments • MO.2. MECHANICAL SCHEDULES: 1) •The make-up air/supply air units listed on Sheet K-7 are not shown on the mechanical schedule Refer to 2010 CMC, Section 609 This provision applies to air-moving systems (AHU's/HVAC Units) supplying air in excess of 2,000 CFM • M2.1. MECHANICAL NEW ROOF PLAN: 1) •Are all new and existing air-moving systems (AHU's/HVAC Units) supplying air in excess of 2,000 CFM equipped with duct smoke detectors in accordance with 2010 CFC, Section 907.4.1 and 2010 CMC, Section 609? Revise the drawings and notes accordingly and clanfy how the installing contractor intendeds to achieve compliance with the code sections cited above. • P0.1. PLUMBING LEAD SHEET: 1) •Add the following note onto Sheet PO 1: • All work shall be in accordance with the 2010 California Plumbing Code (CPC) Part 5, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Plumbing Code (UPC) with 2010 Amendments • EO.1. ELECTRICAL LEAD SHEET: 1) •Delete all references to the "NEC" and add the following note onto the plans: • All work shall be in accordance with the 2010 California Electrical Code (CEC) Part 3, Title 24, California Code of Regulations (CCR) Based on the 2008 National Electncal Code (NEC) with 2010 Amendments • ED.1.1. ELECTRICAL DEMO AND NEW LIGHTING PLAN: 1) •Add the following notes onto Sheet: ED1.1 • Means of egress (MOE) illumination level shall be not less than 1-foot candle at the walking surface and equipped with not less than 90-minute battery backup, 2010 CBC, Section 1006 • Exit signs shall be illuminated at all times and equipped with not less than 90-minute battery backup 2010 CBC, Section 1011 5 3 2) •The lighting plan does not match the layout on Sheet ID2.1. Exit Signs and Emergency Egress Lighting must be shown on Sheet ED 1.1 Revise the drawings accordingly 3) •The configuration and layout must depict exit signage with directional arrows along the path of travel to required exits that lead to the exit discharge 4) •The configuration and layout must also depict emergency egress lighting along the path of travel at all areas ofthe building including outdoor assembly areas. 5) •Provide a complete Lighting fixture schedule containing the type, size, model #, serial #, and specifications for both, the proposed exit signs and overhead or wall-mount lighting fixtures equipped with emergency lighting features (90 minute stand-by ballasts or emergency circuits from an approved source) • E2.1. ELECTRICAL NEW POWER PLAN: 1) •Clarify locations of any new GFCI receptacles/outlets (within 6 feet of any water source) • E6.1. ELECTRICAL PANEL SCHEDULES AND SINGLE LINE DIAGRAM: 1) •Update electncal panel schedules to show circuits for emergency lighting and exit signs END OF COMMENTS BLDG. DEPT COPY CORRECTION LIST Page: 1 of 5 Daryl K. James & Associates, Inc. Checked By: Robert Salgado Plan Check Date: 03/28/2013 APPLICANT: Gerald Michaels, Primary Applicant SMS Architects; (949) 757-3240, email gerald@sms-arch.com JURISDICTION: Carlsbad Fire Department, Fire Prevention PROJECT NAME: Legoland Restaurant T I PROJECT ADDRESS: 1 Legoland Dr., Carlsbad, CA 92008 PROJECT DESCRiPTiON: CB130627 - The Legoland Upper Deck Restaurant T.l. project involves demo and renovation work within an existing restaurant, all work is restricted to a total area of 6,325 S F , including existing outdoor patio areas. The scope of work in the A and B occupancies includes the following. New pizza oven and new type I hood, stock to walk-in chiller, buffet/serving station remodel, new finish work in the dining area, and new mechanical, electrical, and plumbing (MEP) Moditications to existing fire alarm and sprinkler systems and new fire protection systems for protecting commercial cooking equipment will be submitted separately as deferred submittal items. This plan review has been conducted in order to venfy conformance to minimum requirements of codes adopted by the Carlsbad Fire Department applicable to the scope of work. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. RESUBI^ltfAMNS^ 1. Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates. 2. Provide a written response following each comment. On This Correction List, explaining how and where you've addressed each plan review comment. 3. Provide a copy of Building Department (EsGil) comments. Input fire revisions onto the Building Dept. plan check. 4. Please direct any questions regarding this review directly to: Robert Salgado at: (951) 541- 4380, or to his email address at: fisreview inspection@roadrunner.com COMMENTS MUST BE SUBMITTED DIRECTLY TO THE FOLLOWING ADDRESS TO AVOID iE'irAY:; Attn: Robert Salgado 36341 Flower Basket Road Winchester, CA 92596 FIRE PROTECTION SYSTEM PLAN REVIEW: A0.1. GENERAL NOTES AND SHEET INDEX: 1) Update the information under the sub-heading "DEFERRED SUBMITTALS" on Sheet AO 1 and insert the following text Deferred Submittal Items: a Fully-Automatic Fire Spnnkler System, California 2010 Fire Code, Section 903, and NFPA 13, 2010 edition Architect of record (AOR) to consult with the city of Carlsbad Fire Marshal for design criteria (hazard class/density) required for all uses and occupancy groups associated with this project b Fire Alarm and Detection System, 2010 CFC, Sections 907 1 through 907 9 (which includes all other uses and occupancy groups associated with this project), and NFPA 72, 2010 edition Specify type of system Manual or automatic, combination automatic/manual alarm and detection system, and specify spnnkler monitonng requirements in accordance with 2010 CFC, 903 4 through 903 4 2 c Protection of Commercial Cooking Systems, 2010 CFC, Section 904 11 [Specify the type of automatic extinguishing system(s) that the owner plans to install in the kitchen] NOTE All existing dry chemical and wet chemical extinguishing systems shall comply with UL 300 AO.2. CODE SUMMARY AND EXITING: 1) For construction type, clarify the meaning of "UNPROTECTED SPRINKLERED" as it applies to this project, are there any CBC substitutions utilized? 2) Update the "CODE SUMMARY" to show the edition/year of amended model codes, and all NFPA Standards applicable, as listed below • 2010 California Building Code (CBC) Part 2, Volume 1 and 2, Title 24, California Code of Regulations (CCR) Based on the 2009 International Building Code (IBC) with 2010 Amendments 2010 California Mechanical Code (CMC Part 4, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Mechanical Code (UMC) with 2010 Amendments 2010 California Electrical Code (CEC Part 3, Title 24, California Code of Regulations (CCR) Based on the 2008 National Electrical Code (NEC) with 2010 Amendments 2010 California Plumbing Code (CPC) Part 5, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Plumbing Code (UPC) with 2010 Amendments 2010 California Fire Code (CFC) Part 9, Title 24, California Code of Regulations (CCR) Based on the 2009 International Fire Code (IFC) with 2010 Amendments NFPA STANDARDS • NFPA 13, Standard for the Installation of Spnnkler Systems • NFPA 17A, Wet Chemical Extinguishing Systems, 2002 Edition • NFPA 72, National Fire Alarm Code, 2010 Edition • NFPA 96, Ventilation Control and Fire Protection of Commercial Cooking Operations, 2008 Edition (incorporated by reference in the California Mechanical Code - Ch. 5, Part II) 3) Update the "PROJECT DESRIPTION" to reflect a code analysis that defines separate allowable areas fbr the A and B occupancies (include all assembly rooms, kitchen spaces, and outdoor patio areas in the calculations) 4) Two separate exits are required at both outdoor dining areas Patio Dining #1 and Patio Dining #2 are not used for service of the building and individually house more than 100 occupants; therefore, the provisions of 2010 CBC, Sections 1004.8; 1015.2 1; and Table 1015.1 applies. Revise the floor plan and corresponding door schedule to show Panic Hardware at all exterior exit gates serving the outdoor patio areas. 5) QUESTION: Are the outdoor patio areas covered? If yes, are they fully-sprinkled in accordance with the 2010 CFC and NFPA 13? 6) QUESTION: Is the Architect of Record (AOR) proposing to use double-acting doors as part of the means of egress, as shown at both ends of the new Buffet? Please clanfy the proposed exiting requirements from the kitchen, adjoining spaces, dishwashing room, prep area, servery, and along the path of travel to an exterior exit. 7) Provide portable fire extinguishers for commercial cooking equipment; refer to 2010 CFC, Section 904 11.5 (Show symbol for Class K rating). A2.1. FLOOR PLAN: 1) Two separate exits are required at both outdoor dining areas: Patio Dining #1 and Patio Dining #2 are not used for service of the building and individually house more than 100 occupants; therefore, the provisions of 2010 CBC, Sections 1004 8; 1015.2.1; and Table 1015.1 applies. Revise the floor plan and corresponding door schedule to show Panic Hardware at all exterior exit gates serving the outdoor patio areas. 2) Revise the floor plan and door schedule to show "Door Tags" with Letters and/or Numbers at each required exit door and extenor gates that serve more than 50 occupants whether the doors or gates are new or existing The first column in the door schedule needs to show the door tag identification and the end column labeled "Remarks" must call-out the words "Panic Hardware." 3) Clarify 1-hour separations (F R construction) between the "A-3" and "B" occupancies. The Floor Plan Notes, Key Notes, and Legends/Symbols on sheets AO.2 and A2.1 do not accurately reflect the requirements specified in 2010 CFC Table 508.4. NOTE: Exception d. only applies to the seating areas served by the kitchen, all other walls must be 1-hr; example. Restroom, janitor closets, etc. 4) Update the door schedule to show a column marked "Hourly Rating" and identify which doors are required to be rated, example; 45 Mm, 60 Min, %-Hr, etc. A2.3. ROOF PLAN: 1) Specify the required Roof Covering Classification of any new built-up roof assemblies or repairs to the existing roof covering; refer to 2010 CBC, Chapter 15 A3.1. MISC. ELEVATIONS: 1) Revise Detail 4/A3 1 to call-out 2-Hour construction on the exhaust shaft serving the hood and duct system. Refer to Sheet M0.1 "Commercial Cooking Notes" 8. And 9., and Sheet M5.1 Detail 5/M5 1 A9 1. DETAILS: 1) Specify the required Roof Covenng Classification of any new built-up roof assemblies (Curb Flashing or Equipment Platform), or repairs to the existing roof covenng, refer to 2010 CBC, Chapter 15 K-7. REFRIGERATION DATA PLAN 1) Revise code references in the refngeration notes to include the following • 2010 California Mechanical Code (CMC) Part 4, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Mechanical Code (UMC) with 2010 Amendments • 2010 California Electncal Code (CEC) Part 3, Title 24, California Code of Regulations (CCR) Based on the 2008 National Electrical Code (NEC) with 2010 Amendments • 2010 California Plumbing Code (CPC) Part 5, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Plumbing Code (UPC) with 2010 Amendments • 2010 California Fire Code (CFC) Part 9, Title 24, California Code of Regulations (CCR) Based on the 2009 International Fire Code (IFC) with 2010 Amendments 2) Revise the refngeration notes to incorporate the applicable provisions contained in the 2010 CFC, Section 606, only list those requirements that apply to cooler/freezer room K-7. EXHAUST AND MAKE-UP AIR PLAN: 1) Clarify the provisions 2010 CMC, Section 609 This provision applies to all air-moving systems (AHU's/HVAC Units) supplying air in excess of 2,000 CFM K-9. GENERAL BUILDING DETAILS: 1) Revise Details 5/K-9 and 6/K-9 to call-out 2-Hour construction on the exhaust shaft serving the hood and duct system Refer to Sheet MO 1 "Commercial Cooking Notes" 8 And 9 , and Sheet M5 1 Detail 5/M5 1 MO 1. MECHANICAL LEAD SHEET- 1) Add the following note to the "General Notes" box • All work shall be in accordance with the 2010 California Mechanical Code (CMC) Part 4, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Mechanical Code (UMC) with 2010 Amendments MO 2. MECHANICAL SCHEDULES: 1) The make-up air/supply air units listed on Sheet K-7 are not shown on the mechanical schedule Refer to 2010 CMC, Section 609 This provision applies to air-moving systems (AHU's/HVAC Units) supplying air in excess of 2,000 CFM M2.1. MECHANICAL NEW ROOF PLAN: 1) Are all new and existing air-moving systems (AHU's/HVAC Units) supplying air in excess of 2,000 CFM equipped with duct smoke detectors in accordance with 2010 CFC, Section 907.4.1 and 2010 CMC, Section 609? Revise the drawings and notes accordingly and clarify how the installing contractor intendeds to achieve compliance with the code sections cited above. P0.1. PLUMBING LEAD SHEET: 1) Add the following note onto Sheet P0.1' • All work shall be in accordance with the 2010 California Plumbing Code (CPC) Part 5, Title 24, California Code of Regulations (CCR) Based on the 2009 Uniform Plumbing Code (UPC) with 2010 Amendments E0.1. ELECTRICAL LEAD SHEET: 1) Delete all references to the "NEC" and add the following note onto the plans: • All work shall be in accordance with the 2010 California Electncal Code (CEC) Part 3, Title 24, California Code of Regulations (CCR) Based on the 2008 National Electrical Code (NEC) with 2010 Amendments ED.1.1. ELECTRICAL DEMO AND NEW LIGHTING PLAN: 1) Add the following notes onto Sheet: EDI 1. • Means of egress (MOE) illumination level shall be not less than 1-foot candle at the walking surface and equipped with not less than 90-minute battery backup, 2010 CBC, Section 1006 • Exit signs shall be illuminated at all times and equipped with not less than 90-minute battery backup. 2010 CBC, Section 1011.5.3 2) The lighting plan does not match the layout on Sheet ID2.1. Exit Signs and Emergency Egress Lighting must be shown on Sheet ED.1.1. Revise the drawings accordingly. 3) The configuration and layout must depict exit signage with directional arrows along the path of travel to required exits that lead to the exit discharge 4) The configuration and layout must also depict emergency egress lighting along the path of travel at all areas of the building including outdoor assembly areas. 5) Provide a complete Lighting fixture schedule containing the type, size, model #, senal #, and specifications for both, the proposed exit signs and overhead or wall-mount lighting fixtures equipped with emergency lighting features (90 minute stand-by ballasts or emergency circuits from an approved source) E2.1. ELECTRICAL NEW POWER PLAN: 1) Clanfy locations of any new GFCI receptacles/outlets (within 6 feet of any water source). E6.1. ELECTRICAL PANEL SCHEDULES AND SINGLE LINE DIAGRAM: 1) Update electrical panel schedules to show circuits for emergency lighting and exit signs. END OF COMMENTS 5 j^^^Middleby F13 Marshall PS540 Series CONVEYORS OF EXCELLENCE Direct Gas Fired Conveyor Oven RECOMMENDED MINIMUM CLEARANCES Rear of Oven to Wall Control end of conveyor to wall Non-control end of conveyor to wall 0" 0" 0" Heating Zone Baking Area Belt Length GENERAL SPECIFICATIONS Maximum Bal(e Beit Operating Time Width Length Height Depth Temp Range Ship Wt Ship Cube PS540-1 40-1/2" 1028mm PS540-2 81" 2056mm 9sq.ft. 76-1/2" 1x32" (813mm) 80" 47-5/16" 60-1/2" SSCF 3-00-30:00 llOOIbs. 132ft3 0 837m2 1943mm or 2032mm 1202mm 1537mm 288''C or 499kg 3 70m3 2x15"(381mm) 1-00-10:00 ISsqft 76-1/2" 1x32" (813mm) 80" 60-7/8" 60-1/2" 550°F 3:00-30:00 2200lbs. 264ft^ 1.674m2 1943mm or 2032mm 1546mm 1537mm 288''C or 999kg 7 39m= 2x15"(381mm) 1:00-10-00 O PS540-3 121.5" 27sqft 3084mm 2 511m2 76-1/2" 1x32" (813mm) 80" 76" 60-1/2" 550°F 3:00-30 00 3300lbs. 396ff^ 1943mm or 2032mm 1930mm 1537mm 288°C or 1498kg 11 09m^ 2x15"(381mm) 1 00-10.00 ELECTRICAL SPECIFICATIONS Version Voltage Phase Freq Current Draw Supply Breakers USA & std export 208-240V 1 50/60HZ 4 1 Amp 3 wire (2 hot, 1 ground) As per local codes Europe (CE) 220-230V 1 50Hz 4 1 Amp 3 wire (2 hot, 1 ground) As per local codes " The current draw rating shown above are maximum values for normal operation, amperage draw will be less than the listed value NOTE: Each oven includes a 6' cord with NEMAIt L6-20P plug. Customer to provide NEMA# L6-20R receptacle r GAS SUPPLY SPECIFICATIONS Version Gas Type North America IE,IT,PT,ES,G8 OE NL BE.FR AT,CH,DK,FI,SE Rated Heat Input USA & std export Natural Gas 6-12-WC. (14 9-29 9mbar) ----IIO.OOOBTU (32 23kW-hr) USA & std export Propane Gas 11-14"WC (27 4-34 9mbar) • -: -: IIO.OOOBTU (32 23kW-hr) Europe (CE) G20 -20nibar 20mbar -20-25mbar 20mbar 32 23kW-hr Europe (CE) G25 --20mbar 25mbar --32 23kW-hr Europe (CE) G20, G25 -20mbar 20mbar 25mbar 20-25mbar 20mbar 32 23kW-hr Europe (CE) G30 -29-37nibar -28-30mbar 29-37mbar SOmbar 32 23kW-hr Europe (CE) 630, G31 --SOmbar 30mbar -SOmbar 32 23kW-hr The required gas supply pressures of other locations are dependent on the local gas type and on all applicable local codes Minimum Gas Pipe Sizes: ' Natural Gas - 2" (51 mm) mam supply line. One 3/4" (19mm) NPT branch per oven cavity with individual full-flow shutoff valve. * Propane Gas -1 1/2" (31 8 mm) mam supply line. One 3/4" (19mm) NPT branch per oven cavity with individual full-flow shutoff valve NOTE: Each oven includes (1) 3/4"(19mm)NPT x 48"(1219mm) flexible, vinyl coated stainless steel braided gas hose. ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. nmMiddleby MM Marshall ® 2011 Middleby Marshall, Inc Middleby Marstiall, in accord with its policy to continually improve its products, reserves the nght to change matenals or specifications without notice Such revisions do not entitle the buyer to correspond- ing changes, improvements, additions, or replacements for previously purchased equipment THE BRAND BEHIND THE BRANDS 1400 Toastmaster Dnve, Elgin, IL 60120-9272, USA • (847)741-3300 • Fax-(847) 741-0015 Form 4505 03/11 www middleby-marshali com SECTION 2 INSTALLATION UTILITY ROUGH-IN DIMENSIONS AND POSITIONING FOR PS540-SERIES OVENS WARNING DO NOT USE CONDUIT OR GAS LINE FOR GROUND CONNECTION. CAUTION IT IS REQUIRED THAT THE OVEN BE PLACED UNDER A VENTILATION HOOD FOR ADEQUATE AIR SUPPLY AND VENTILATION. ELECTRIC AND GAS SUPPLY TO BE PROVIDED BYCUSTOMER ELECTRICAL SAFETY SWITCH 15 Amp circuit breaker / fused disconnect switch with lockout/tagout electrical shutoff for each oven. Wire each oven separately. ELECTRICAL SPECIFICATIONS DOMESTIC or EXPORT: 208-240V blower motor, 1 phase, 4.1 Amp draw, 50/60 Hz, 208-240V control circuit, 2 poles, 3-wire system per oven (2 hot, 1 grd). Do NOTuse conduit for ground. GAS RATING Model PS540 is 110,000 BTU/hour, 116.0 m J/h (27,720kcal), 32.2kW/hr. MINIMUM GAS METER RATING 450 nVhour (12.6mVh) for 1 or 2 ovens; Add 180 cu. ft./hr (5.1 m^/h) for each additional oven. Minimum rating does nof take other gas appliances into consideration. Gas consumption varies at each site. Total BTU/hr (kcal/hr) must be calculated during high flame operation for each appliance to determine if the meter needs to be larger. MINIMUM GAS PIPE SIZE Natural: 2" (51 mm) ID for 1,2, or 3 ovens with runs up to 200 ft. (61m). Must be a dedicated line. Runs over 200 ft, (61 m) consult factory. Propane: 2" (51 mm) ID for 1,2, or 3 ovens with runs up to 200 ft. (61m). Must be a dedicated line. Runs over 200 ft, (61 m) consult factory. 24- 610mm Suggested dimensions are shown; utility code requirements supersede any factors shown Figure 2-9. Typical PS540-Series Oven(s) Installation GAS SAFETY VALVE A 3/4" (19mm) ID (inner diameter) full-flow, gas shutoff' valve. A separate connection and valve must be provided for each oven, as shown in Figure 2-9. REQUIRED GAS SUPPLY PRESSURE Natural: 6" to 12" water column (13.8 to 29.9 mbar) Propane: 11.5" to 12" water column (28.7 to 29.9 mbar) SUGGESTED If space permits, electric and gas service should be located near the control console end ofthe oven(s) to allow convenient access to safety switches and valves. USER SUPPLIED ITEMS (Figure 2-9) ITEM DESCRIPTION 1 2" (51mm) x 2" (51mm) x 3/4" {19mm) TEE 2 3/4" (19mm) X 3" (76mm) NIPPLE 3 3/4" (19mm) FULL FLOW GAS SHUTOFF VALVE 4 2" (51 mm) x 3/4" (19mm) 90° REDUCER ELBOW 5 2" (51 mm) ID GAS SUPPLY PIPE LINE - NATURAL GAS 6 15 AMP TOGGLE SWITCH-2 POLE for GAS 17 o LEGOLAND CALIFORNIA Plumbing Calculations Natural Gas 5.0 PSI System - Existing 1 1/4" Building Service Lateral Project Name UPPER DECK Tl Project Number 2013027.0 Prepared By: Ron Jones exp U.S. Services Inc. 5670 Oberlin Dnve San Diego, CA 92121 USA Date Submitted 04.16.13 (Updated) Basis for PE Pipe Calculations TABLE 12-11 SCHEDULE 40 METALLIC PIPE [NFPA 54: TABLE 6.2(e)] FUEL PIPING \l GAS: NATURAL NOT USED INLET PRESSURE: 5.0 psi PRESSURE DROP: 3.5 psi SPECIFIC GRAVITY: 0.60 PIPE SIZE (inch) NOMINAL: % 1 WA 2 2'/4 3 4 ACTUAL ID: 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 LENGTH (ft) CAPACrrV IN CUBIC FEET OF GAS PER HOUR 10 3,190 6,430 11,800 24,200 36,200 69,700 111,000 196,000 401,000 20 2,250 4,550 8,320 17,100 25,600 49,300 78,600 139,000 283,000 30 1,840 3,720 6,790 14,000 20,900 40,300 64,200 113,000 231,000 40 1,590 3,220 5,880 12,100 18,100 34,900 55,600 98,200 200,000 50 1,430 2,880 5,260 10,800 16,200 31,200 49,700 87,900 179,000 60 1,300 2,630 4,800 9,860 14,800 28,500 45,400 80,200 164,000 70 1,200 2,430 4,450 9,130 13,700 26,400 42,000 74,300 151,000 80 1,150 2,330 4,260 8,540 12,800 24,700 39,300 69,500 142,000 90 1,060 2,150 3,920 8,050 12,100 23,200 37,000 65,500 134,000 100 979 1,980 3,620 7,430 11,100 21,400 34,200 60,400 123,000 125 876 1,770 3,240 6,640 9,950 19,200 30,600 54,000 110,000 150 786 1,590 2,910 5,960 8,940 17,200 27,400 48,500 98,900 175 728 1,470 2,690 5,520 8,270 15,900 25,400 44,900 91,600 200 673 1,360 2,490 5,100 7,650 14,700 23,500 41,500 84,700 250 558 1,170 2,200 4,510 6,760 13,000 20,800 36,700 74,900 300 506 1,060 1,990 4,090 6,130 11,800 18,800 33,300 67,800 350 465 973 1,830 3,760 5,640 10,900 17,300 30,600 62,400 400 433 905 1,710 3,500 5,250 10,100 16,100 28,500 58,100 450 406 849 1,600 3,290 4,920 9,480 15,100 26,700 54,500 500 384 802 1,510 3,100 4,650 8,950 14,300 25,200 51,500 550 364 762 1,440 2,950 4,420 8,500 13,600 24,000 48,900 600 348 727 1,370 2,810 4,210 8,110 12,900 22,900 46,600 650 333 696 1,310 2,690 4,030 7,770 12,400 21,900 44,600 700 320 669 1,260 2,590 3,880 7,460 11,900 21,000 42,900 750 308 644 1,210 2,490 3,730 7,190 11,500 20,300 41,300 800 298 622 1,170 2,410 3,610 6,940 11,100 19,600 39.900 850 288 602 1,130 2,330 3,490 6,720 10,700 18,900 38,600 900 279 584 1,100 2,260 3,380 6,520 10,400 18,400 37,400 950 271 567 1,070 2,190 3,290 6,330 10,100 17,800 36,400 1,000 264 551 1,040 2,130 3,200 6,150 9,810 17,300 35,400 1,100 250 524 987 2,030 3,030 5,840 9,320 16,500 33,600 1,200 239 500 941 1,930 2,900 5,580 8,890 15,700 32,000 1,300 229 478 901 1,850 2,770 5,340 8,510 15,000 30,700 1,400 220 460 866 1,780 2,660 5,130 8,180 14,500 29,500 1,500 212 443 834 1,710 2,570 4,940 7,880 13,900 28,400 1,600 205 428 806 1,650 2,480 4,770 7,610 13,400 27,400 1,700 198 414 780 1,600 2,400 4,620 7,360 13,000 26,500 1,800 192 401 756 1,550 2,330 4,480 7,140 12,600 25,700 1,900 186 390 734 1,510 2,260 4,350 6,930 12,300 25,000 2,000 181 379 714 1,470 2,200 4,230 6,740 11,900 24,300 Note: All table entries are rounded to 3 significant digits. 2010 CALIFORNIA PLUMBING CODE 223 NOT USED - Utilizing Mueller equation for gas flow {greater than 1 psig), see MG PE Pipe Calc mote outlet and the load of the section (See calculation eX' ample in Figure 12-2). [NFPA 54:6.1.1] I 1217.1.2 Branch Length Method. Pipe shall be sized as follows: [NFPA 54:6.1.2] (A) Pipe size of each section of the longest pipe run from the point of delivery to the most remote outlet shall be detennined using the longest run of piping and the load ofthe section. (B) The pipe size of each section of branch piping not previously sized shall be determined using the length of piping from the point of delivery to the most remote outlet in each branch and the load of the section. I . 1217.1.3 Hybrid Pressure. The pipe size for each sec- tion of higher-pressure gas piping shall be determined using the longest length of piping from the point of de- livery to the most remote line pressure regulator. The pipe size from the line pressure regulator to each outlet shall be determined using the length of piping from the regulator to the most remote outiet served by the regula- tor. [NFPA 54:6.1.3] I 1217.2 Tables for Sizing Gas-Piping Systems. Tables 12-8 through 12-41 shall be used to size gas piping in conjunction with one (1) of the methods descnbed m Sections 1217.1.1 through 1217.1.3. [NFPA 54:6.2] I 1217.3 Sizing Equations. The inside diameter of smooth-wall pipe or tubing shall be determined by the sizing equations 12- 1 or 12-2, using the equivalent pipe length determined by Sec- tions 1217.1.1 through 1217.1.3. [NFPA 54:6.4] (Equation 12-1 Low-Pressure Gas Formula (Less than 1.5 psi [10.3 kPa]): [NFPA 54:6.4.1] D= Q 10.381 19.17 XCZZL) 206 where: D = inside diameter of pipe, inches Q = input rate appliance(s), cubic feet per hour at 60°F (16°C) and 30-inch (759 mm) mercury column Pi = upstream pressure, psia {Pi + 14.7) P2 = downstream pressure, psia (P: + 14.7) L = equivalent length of pipe, feet A// = pressure drop, inches water column (27.7 in. H2O • 1 psi) FUEL PIPING where: D = inside diameter of pipe, inches Q = mput rate appliance(s), cubic feet per hotir at 60°F (16°C) and 30-inch (759 mm) mercury column Pi = upstream pressure, psia (Pi + 14.7) P2 = downstream pressure, psia (P2 + 14.7) L = equivalent length of pipe, feet AH = pressure drop, inches water column (27.7 in. H2O • 1 psi) TABLE 12-4 Cfl AND YFOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS [NFPA 54: TABLE 6.4.2] FORMULA FACTORS GAS Cr Y Natural Gas 0.6094 0.9992 Undiluted Propane 1.2462 0.9910 For SI units, 1 ft ^ = 0.028 m^; 1 ft = 0.305 m; 1 in water column = 0.249 kPa; 1 psi = 6 894 kPa; 1,000 Btu/h = 0.293 kW. 1217.4 To detennine the size of each section of pipe in any system within the range of the Table, proceed as follows: | (A) Measure the length of the pipe from the gas meter loca- tion to the most remote outlet on the system. (B) Select the length in feet column and row showing the dis-1 tance, or the next longer distance if the table does not give the exact length. (C) Starting at the most remote outlet, find in the row just se- lected the gas demand for that outlet. If the exact figure of demand is not shown, choose the next larger figure in the row. (D) At the top of this column will be found the conect size of pipe. (E) Using this same row, proceed in a similar manner for each section of pipe serving this outlet. For each section of pipe, determine the total gas demand supplied by that section. Where gas piping sections serve both heating and cooling appliances and the installation prevents both | units from operating simultaneously, only the larger of the two (2) demand loads needs be used in sizing these sections. (F) Size each section of branch piping not previously sized by measuring the distance from the gas meter location to the most remote outlet in that branch and follow the pro- cedures of steps B, C, D, and E above. | 2010 CAUFORNIA PLUMBING CODE 217 MG PE Pipe Calc: (E)1 1/4" Branch Main (5.0 PSI) - Max SCFH Capacity: (based of DRISCQPLEX Series MDPE Gas Distribution Pipe) Reference: PPI Polyethylene Design Handbook PLAS1 irs Pii'iMNSTn uxn Gas Flow High Pressure Gas Flow * ref Mueller equolion for ,-! • QQS flow (>]psi3) ] Q = 2826Di2-^25 ^ (p, +147)2. (p^ + 14,7)2 n.575 0.42S [ Information Date Project Engineer Name Comments 04-15-2013 i Upper Deck Tl; LEGOLAND, California Resort ! RJones/exp U.S. Services Inc. ' (E)1 1/4-inch calculated CFH capacity @ 850 FT Total Developed Length (Site meter to bldg regulator) Variables Do . 0 DR ; ° Sg , 0.667 _ 850 Pipe Outside Diameter, in Dimension Ratio 0.667 I Specific Gravity Length, ft Result Calculated for: Q I '-'1 1.328 See PE Pipe Data Sheet Q { 2422.34 Pi j 5.0 P2 i 1.5 Inside Diameter, in Flow Rate, scfh inlet pressure, psig outlet pressure, psig Maximum Capacity PERFORMANOEPIPE A DIVISION OF CHCvm PHILLIPS CHIMICAL COMPANY LP CTS = Copper Tube Size SSteDOGseasa) • ms& fCTifliilHiiL casa? ' mm peas ' (ffmftTFtl-, (smo '[ : EnnHfe (Mm • • 55033^5 aim 1/2" 7 0.625 0.09 100 6.5 1,000' 30°/4476" 12 12,000' 26 312,000' r 11-.5 1.125 \ • 0.099 ^ 14 500' 30742"/ir 8 4,000' . 26 104,000' IPS = Iron Pipe Size [E]Bldg Supply Lateral Nominal ID 1.328" • mss • lJEi7(Hs2l]£^ / (IN) EEC? seaaMiiB - Rrnr^m mm? ffiliiflitfl • mss • lJEi7(Hs2l]£^ / (IN) EEC? seaaMiiB - Rrnr^m mm? 3/4" 11 1 05 0 095 / 80 12 500' 30"/44"/10" 7 3,500' 26 91,000' 1" 11 1.315 0.12 / 80 19 500' 30"/44"/12" 6 3,000' 26 78,000' 1 1/4" 10 1.66 0166 ^ ' 89 33 500' 48"/72"/7-1/2" 12 6,000' 7 42,000' 1 1/2" 11 1.9 0173 ' • 80 40 500' 48'/75'/8-1/2" . -8 4.000' 7 28,000' 2" 11 2.375 0.216 80 63 500' 52"/78"/13" 7 3,500' 7 24,500' 3" ' 11 3.5 0.318 , - 136 500' 70'/96"/23-3/4" 4 2,000' 6 12,000' 3" ' 11.5 3.5 > 0.304 76 131 40' soft bundles 50 , 2,000' -14 28,000' 3" ' 11.5 3.5 > 0.304 76 131 500' 70"/g6'/23-3/4" 4 2,000' 6 12,000' 4" 11 45 0 409 80 225 500' 70"/93"/41" 2 1,000' 6 6,000' 4" 11 5 4.5 0.391 76 217 40' soft bundles 29 1,160' 14 16,240' 4" 11 5 4.5 0.391 76 217 600' 70"/93"/49-1/2° upright 1,160' 12 7,200' 4" 11 5 4.5 0.391 76 217 1,000' 847116"/49" upnght 1,160' 8 coils 8,000' 6" 11.5 6.625 0.576 ' 76 • 471 40' soft bundles 13 . 520' 14 7,280'' 6" 11.5 6.625 0.576 ' 76 • 471 ' 500' 847120750" upright 520' ' 8 coils 4,000' 6" 135 6.625 • 0.491 64 407 ~ > 40' soft bundles 13 ; 520' 14 7,280' • 6" 135 6.625 • 0.491 64 407 ~ '500'' 84"/120"/50" upright 520' 8 coils 4,000' 8" 11 5 8.625 0.75 76 798 40' soft bundles 9 360' 10 3,600' 8" 13.5 8.625 0 639 64 690 40' soft bundles 9 360' 10 3,600' 12" 13.5 12.75 0.944 64 1507 --40' bulk packs 8 joints/layer 320' 6 1,920' This product flyer Is intended for reference purposes. It should not be used in place ofthe advice from a licensed Professional Engineer. Pressure Rating is based on an operating temperature of 73°F per 49 CFR 192. Pipe weights are calculated in accordance with PPI TR-7. Nominal OD and Minimum wall plus 6% is used in estimating fluid flow. Actual ID will vary. When designing components to fit the pipe 10, refer to pipe dimensions and tolerances In the applicable pipe manufacturing specification. Bulletin PP 3131 December 2012 www.performancepipe com © 2012 Chevron Phillips Chemical Company LP Perfomnance Pipe, a division of Chevron Phillips Chemical Company LP | 5085 W. Park Blvd | Suite 500 | Piano, TX 75093 | Phone:800-527-0662 | Fax. 972-599-7329 eVTY 'O.F, PnnMBfNon ECJECTULCAtj^ A/VnpuScEET B48 Development Services Building Division 1635 faraday Avenue 760-602r2719 www.canlsbadca.gov Rrdject Address: Permit No.: Informatrdn'provided below itefers to worh being dbne ori'the above,mentldned;permit only. This form must be completed awd returned to-the Building Division before the permit con be issued. Building,Dept: Fax; (760) 602-8558 5 Nurnber of new or relocated fixtures, trap5,.or floor drains, y New building sewer line? , Ves No Number of new ro}6f di'qiris?.,.;,;^.....,...,.,...........,...,.. , YES Install/alter watei: line?...:.......-...;.. , . n/s Number of new water beaters?*. , 6 N^um'ber of'hew/.relocqted or, replaced gas outlets? • ~ Number of new hose bibs? n/a Residential; Permitsr "New/expanded service: Number of new amps: Mirior Plehiode) on/y: Ves] No, Commercial/industrial: Tenant Improvement: Number of existing amps inuolvedin this project: Number df new dmps irivohedin this project: ?«lew Construction: Amps per Panel: Single Phase Number of new.amperes_ Three Phase Number of new amperes^ f hreelPhase 480 ....T.....™..-............ Nurnber of new amperes^ Number oi new furnaces, A/C, or heat pumps? New or relocated duct worb? ; Ves 217 Amps 60 Amps n/a n/a n/a 0, 1 makeup air unit providing nonconditioned air No Number of new fireplaces?' .-. •"• • _0— Number of new exhaust fans?..... , : • Relocate/ihstallsuent?,.. :v Number of new.exhaust hopds? ..........,.....;....... j.:.-;............,.,...-.,..:...:....,.:. _Q, Number of new Boilers pr corripressors? ..i.............;......-....;.........,.;.r.:. Nurnb,ef of HP E B-18-Paae 1 of 1. Rev ,03/09 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# BPDATE / / Business Name Business Contact Telephone # ( ^ Project Address . I l«so Wv\c\ . City State Zip Code Ch «ii<30?, APN# Zll • JOO - o«t Mailing Address City state Zip Code-PlanFile# Project Contact . , Telephone #* The following questions represent the facility's activities', NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the follow'ing hazardous matenals lf_any ofthe items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan'-submittal Facility's Square Footage (including.proposed project): (of 'Occupancy Rating: ^3 1 Explosive or Blasting Agents 5' Organic Peroxides 9 Water Reactives 13 Corrosives 2 Compressed Gases> ' 6 Oxidizers 10 Cryogenics 14 Other Health Hazards 3 Fiammable/CombustiBle Liquids 7 Pyrophorics 11 Highly'Toxic or Toxip Materials 15 None of These 4 Flammable Solids 8 Unstable Reactives> 12 Radioactives PART II. SAN DIEGO COUNTY DEPARTIVIENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Matenals Division, 5500 Overland Ave , Suite 110, San Diego, CA 92123 Call (858) 50S-6700 pnor to the issuance of a building'permit (e> I jO I Expected Date of Occupancy <P / I| / FEES ARE REQUIRED YES NO 1 • 2 • 3 • 4 • ,5 • 6 • 7. • Project Completion Date. • CalARP Exempt Date Initials • CalARP Required I Date Initials • CalARP Complete ' L Date initials (for new construction or remodeling projects) Is your business listed on the reverse side of this form'' (check all that apply) Will your business dispose of Hazardous Substances or Medical Waste m any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than.55 gallons, 500 pounds 200 cubic feet, or carcinogens/reproductive toxins in any quantity"? , Will your business use an existing or install an underground storage .tank'' Will your business store or handle Regulated Substances (CalARP)'' Wiii your business use or install a,Hazardous Waste Tank System (Title-22, Article 10)'' Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons'' (California's Aboveground Petroleum Storage' Act) PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, ^applicant must contact the Air, Pollution Control Distnct (APCD), 10124 Old Grove Road, San'Diego, CA 92131-1649, telephone'(858) 586-2600 prior to the-issuance of a building or demolition permit Note' if the answer to.questions 4 or 5 is yes, applicant must also submit,an asbestos notification "form to the'APCD at ieast'10 working days pnor to commencing demolition or renovation, except rl'efnoii'.on or roi jovat'nn of residential structures of.four units pr less. Contact the APCD for more information YES NO • Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminanf (See the APCD factsheet at'http I/VJWVJ bdapcd oro/info/facts/permits pdf, and the list of typical equipment requmng' an APCD permit on the reverse side of this from Contact APOD if you have any questions). • -Q^ (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)'' (Search the California School Directory at http-//wvw cde ca gov/re/sd/ for'pubiic-and pnvate schools or contact the appropnate school distnct) /&• >• Has a survey been perforrhed to determine the p'resence of Asbestos Co'ntaining Materials''(^\i.O»'*^'^ •&)t.i^>"nt^c. TO ^M<^(*J"^ • Will there be renovation that invoives.handling of any friable asbestos matenals, or disturbing any matenal that contains non-fnable asbestos' • Will.there be demolition involving the removal of a load supporting structural member? 1 Bnefly describe business activities I declqfe under penaltv of perjury that to the best of my'lsnowledge and belief the Name of Owner or Authorized Agent' Briefly descnbe proposed project Signature df Owner or Authorized'Agent 3 I is J 13 Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION . BY . .__ FOR OFFICIAL USEONLY. DATE EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD CPUNTY-HMD APCD *A Stamp in this box onlv exempts businesses from completing or updating a Hazardous Matenals-Business Plan- Other permitting requirements may still apply uht iini /ml^^^ rotintv ofSjivIOiceci - DLIl - ILizrircloiis Matenah I^ivision Date INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY Business Name Le<jolM.i^\ Street Address \ Lc«|otc.^ei X>^. CA.fe.L s^Lexo-^ (Lti.^Loo<^ .EmailAddress c^<i^a.VgX ^ •^Ea»\g:>- tAim.CMiA^ PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: {ON'REVERSE SIDE CtHECK.TYPE OF BUSINESS) •Check ali below that are present'at-your facility; Acid Cleaning Assembly Automotive Repair Battery Manufacturing Biofuel Manufacturing Biotech'Laboratory Bulk Chemical .Stoi"age Car Wash Chemical Manufacturing Chemical Purification Dry Cleaning Electrical Component* Manufacturing Fertilizer Manufacturing Film / X-ray'Processing Food Processing Glass Manufactt^iring Industrial Laundry Ink Manufaicturing Laboratory Machining / Milling Manufacturing Membranie Manufacturing (i.e. water filter membranes) Metal Casting, / Forming Metal Fabrication Metal Finishing Electroplating Electroless plating Anodizing Coating (i;e. phosphating) Chemical Et(ihing / Milling Printed Circuit Board Manufacturing •Metal Powders Forming Nutritional Supplement/ Vitamin Manufacturing Painting/Finishing Paint Manufacturing Personal. Care Products Mahufacturirig Pesticide Manufacturing / Packaging Phaffnac'eutibat Manufacturing (incliading'precursors) Porcelain Enarneling Power 'Generation Print Shop Research and Development Rubber Manufacturing Semiconductor Manufacturing Soap / Detergent Manufacturing "Nl Waste Treatment / Storage SIC Code(s) (if known):. Brief ;descriptipr;i of business activities (Production / [yianufacturing Operations}:, Description of .operations- generating wastewater (discharged fo sewer, haulecTor evaporated): ^r<e.6?:'Si£'. l^vi^r'^=;rj?'•P^7-Oia--- ^ {'^Co \ (eY^ Cjfiyi.K77r\iA7\\ Estimated volume of industrial Wastewater to be discharged (gal / day):. -List hazardous wastes generated (type/volume): Date operation begahfer will begin at this location: low Haye-4ia2u applied for a Wastewater Discharge Permit from the Enema Wastewateir Authority? LYes3 No If yes, when: ^j-^\\^\ . ^ .__ Site Contact Oj^r-^k \^\c)f\CK^..U^ Title ^vacj 00<^lvm,C ^-v-- Signature /'^j^-^^''^^^^^ Phone Nb._ ENCINA WASTEWATER AUTHORITY7~62tJCrAverfida Encinas Carlsbad.XA 92011 (760) 438-'3'941 / FAX: (760)476-9852 "^CIECfJOMBCR ' CARLSBAD FIRE DEPARTMENT EXPEDITED PLAN CHECK REQUEST I, ,\^U^vias-'^ am requesting 'Expedited Plan Check Services' and understand I will be levied an additional fee assessed at the rate of $90.00 dollars per hour plus $25.00 dollars administration fee. I understand that my plans shall not be released until all fees are paid. '•"'^Z, ^the applicant, am solely responsible for all fees due should the project be withdrawn or otherwise not completed. And by signing below I acknowledge that my plans shall be A/itnc forwarded by the City of Carlsbad to an independent contractor/consultant. I, OQO-J fUovye-'^ acknowledge that the 'first review' time for all expedited Fire plan reviews will be ten- (10) business days from date of subnmittal. These additional day account for acceptance and delivery of your plans and then the parcel return to our office if recommended for approval. >oj! h^f-it I, NJvjvve,/^ the applicant, acknowledges that corrected or revised plans shall be sent directiv to the plan checker, at the address specified on the Correction List, at my cost, parcel post or other means. I, '^»«.y acknowledge that a turn-around time for re-submittals is five- (5) business days from the date plans are received at the address specified by the plan checker on the Correction List. Once all corrections are made, your plans are then returned to the Carlsbad Fire Department with a "Recommendation for Approval" based solely on the adopted Codes and Standards. This is not an approval. Your plans are then forwarded to the Carlsbad Fire Department, and once your plans are received by our office they are subject to an additional review to ensure conformance with Carlsbad Municipal Code. This additional review is subject to an additional review period of seven- (7) 'Government Business' days from date that we receive the plans from the plan reviewer. The Carlsbad Fire Department does not perform 'Over-the-counter' plan review services. Plans submitted to the Carlsbad Fire Department for review by CFD staff shall be checked on a 'first come, first served' basis and could take 10 days or more for 'First' review. Applicant Signature, Copy to Building and Fire Preventioj/fTle Revised lO/lS/2012 PLUMBING SPECIFICATIONS PLUMBING SPECIFICATIONS PLUMBING SPECIFICATIONS PLUMBING DEMOLITION PLAN PLUMBING RENOVATION PLAN PLUMBING DIAGRAMS rRICAL er Sheet Title ELECTRICAL LEAD SHEET ELECTRICAL SPECIFICATIONS ELECTRICAL DEMO AND NEW UGHTING PLAN ELECTRICAL DEMO POWER PLAN ELECTRICAL NEW POWER PLAN ELECTRICAL NEW POWER ROOF PLAN ELECTRICAL DETAILS ELECTRICAL PANEL SCHEDULES AND SINGLE LINE DIAGRAM COUNTY OF SAN WEGO DEPARTMENT OF ENVIRONMENTAL HEALTH PLANCHECK KSMITTEDFOR APPROVAL COUNTY OF SAN D^EGO V DEPARTMENT OF . ENVIRONMENTAL HEALTH PLAN REVIEW P-S.CCEPT|O^^SK-I APPRWSSETFORPUANI %B SITE DURING CONSTRUCTION „UIIIIIIIII,. o C-24991 3-31-13 NO DATE 03-06-13 PERMIT SI A 04/01/13 PLAN CH DRAWINGS AND WRirTEN MATERIAL APPEAR UNPUBUSHED WORK OF SMS ARCHITECTS ; DISCLOSED WITHOUT WRITTEN C PROJECT NO 12048 DATE * Apnl 22, I DRAWING TfTLE GENERAI AND SHE DRAWING NO A 05-29-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No.PCR13083 Building Inspection Request Line (760) 602-2725 Job Adciress Permit Type. Parcel No Valuation. Reference # PC# Project Title 1 LEGOLAND DR CBAD PCR 2111000900 Lot# $0 00 Construction Type CB130627 0 NEW UPPER DECK Tl - CHANGE GAS LINE SIZE FROM 1 1/4" TO 1" PAGES P0.1 AND P5 1 Status Applied Entered By Plan Approved Issued' Inspect Area ISSUED 05/29/2013 LSM 05/29/2013 05/29/2013 Applicant FRANK FRITSCH 5670 OBERLIN DR SAN DIEGO CA 92121 858-597-0555 Owner LEGOLAND CALIFORNIA LLC <LF> PLAY U S ACQUISI C/O PROPERTY TAX SERVICE CO POBOX 543185 DALLAS TX 75354 Plan Check Revision Fee Fire Expedited Plan Review Additional Fees $125 00 $0 00 $0 00 ' Total Fees $125 00 Total Payments To Date $125 00 Balance Due: $0.00 Inspector FINALAPPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exacfions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32.030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othenA/ise expired ^ CITY OF CARLSBAD PLAN CHECK REVISION APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov WTT^o^ Oft— " Plan Check Revision No. "=vSr~ Q(uZ.'^ nrigiml Plan Check No. /-^g>.Qoo.*-A.^ .Date- Contact 'V^a&a\ Ph ^^(gg^SI^-oSSS Fax Email ^^%^y^V, ^ ^y-^cA (g^ PX^.CJC^V^ Contact Adrirp<:<: dolb A'fefi^<A.:> ^>g- City "^Ar^^ ^>£(^c. Zip ^Z-V^V General Scope of Work 0?PF^ "^^ZXCA^ '^i=s.T Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 • Elements revised: • ^ Plans ^ Calculations • Soils • Energy • Other 2. Describe revisions In detail 3. List page(s) where each revision is shown 4. List revised sheets that replace existing sheets ?OX x-5 \ 5. Does this revision, in any way, alter the exterior of the project? • Yes ^ No 6. Does this revision add ANY new floor area(s)? • Yes M No T. Does this revision affect any fire related issues? • Yes No 8. Is this a complete set? • ^ No ^Slgnature- 1635 Faraday AvencUb, CaFfsbad, Cj^ 92008 £{2:760-602-2719 Fax-760-602-8558 ErnaiL building@carlsbadca.gov www.carlsbadca.Qov EsGil Corporation In (Partnersliip wttH government for (ButCcfing Safety DATE: 5/29/2013 • APPLICANT • JURIS JURISDICTION: Carlsbad • PLAN REVIEWER XFILE PLAN CHECK NO.: 13-0627 Rev. (PCR13083) SET I PROJECT ADDRESS: 1 Legoland Dr. PROJECT NAME: Legoland Upper Deck Restaurant TI (revised building gas main sizing) XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. IXI EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Rod Jones Telephone #: Date contacted: 5/29/2013 (by: ga) Email: Fax #: Mail Telephone Fax In Person ^ REMARKS: City has approved the designer hand carrying revised gas line plans from City to Esgil and back to the City. ^ i .cA By: Glen Adamek Enclosures: V/ EsGil Corporation '\) GA • EJ • PC 5/29/2013 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Partnership witli government for <Sui[ding Safety DATE: 5/29/2013 • APPLICANT • JURIS JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 13-0627 Rev. (PCR13083) SET-1 PROJECT ADDRESS: 1 Legoland Dr. PROJECT NAME: Legoland Upper Deck Restaurant TI (revised building gas main sizing) X The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Rod Jones Telephone #: Date contacted: 5/29/2013 (by: ga) Email: Fax #: Mail Telephone Fax In Person ^ REMARKS: City has approved the designer hand carrying revised gas line plans from City to Esgil and back to the City. By: Glen Adamek Enclosures: EsGil Corporation ^ GA • EJ • PC 5/29/2013 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 13-0627 Rev. (PCR13083) 5/29/2013 [DO NOT PAY- THIS IS NOTAN INVOICE] JURISDICTION: Carlsbad (PCR13083) VALUATION AND PLAN CHECK FEE PLAN CHECK NO.: 13-0627 Rev. DATE: 5/29/2013 PREPARED BY: Glen Adamek BUILDING ADDRESS: 1 Legoland Dr. BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING PORTION AREA (Sq Ft) Valuation Multiplier Reg Mod VALUE ($) Air Conditioning Fire Sprinklers TOTAL VALUE Junsdction Ccxie cb By Ordinance Bldg. Permit Fee by Ordnanoe Plan Check Fee by Ordinance -I Type of Review • Repettive Fee ^1 Repeats • Complete Review • Other Hourly 1 sGII Fee $125.00 • Structural Only $100 00 Hr.@ $100.00 Based on hourly rate Comments: hourly rate of $100 00 per hour for one hour. Sheet 1 of 1 macvalue doc + Plumbing Calcyfations l^atyrai Gas - Site Distnbytion System 5.0 PSI System - Existing 1" Building Service Lateral Capacity c5 UPPER DECK Tl Project Number 2013027.0 Pra^ered By: Ron Jones exp U.S. Services Inc. 5670 Oberlin Drive San Diego, CA 92121 USA 05.22.13 Basis for Calculation: California Plumbing Code (2010 ed) Chapter 12 Fuel Piping Section 1271.1 Pipe Sizing Methods, 1217.3 Sizing Equations utilizing modified Equation 12-2 High-Pressure Gas Formula (1.5 psi and above). Mueller Equation for Gas Flow >1pisg Park Wide Gas Load Summary:* (Total CFH calculated demand based on 1 ,OOOBtuh/CFH) Service Water Heating Equipment 3023.80 CFH Space Heating Equipment 6733.50 CFH Appliances 4975.50 CFH Total 14,732.30 CFH *base on existing Parkwide Natural Gas (Btuh) Table, Sheet P0.1 (E) 4"¥iam & Site Distribution Loop: Service Pressure: 5.0 PSI, Design Pressure Drop: 2.0 PSI Total Developed Length: Meter/Main To Loop: 336 FT Overall Loop: 5400 FT Total - 5736 FT Pipe Sizing: Based On 2010 CPC Chapter 12 Fuel Piping, Section 1209.4 & 1217.3 Sizing Equations Utilizing Mueller Equation For Gas Flow (>1 Psig) And As Follows: Natural Gas Specific Gravity; 0.667 Pipe ID (4-lnch PE, SDR 11.5, see attachment 4); 3.71 In. Residual Pressure Calculation (see attachment No 1); Length; Main From Meter + 1/2 Distance Of Loop - 3036 Ft Gas Flow Rate; 14,732.3 SCFH Residual Pressure in Loop; 3.0 PSI (E) 1-ioch Buildiog Supply Lateral: Service Pressure: 3.0 PSI, Design Pressure Drop: 2.0 PSI Total Developed Length: Loop To Building Regulator: 120 Ft Equivalent Length (Valves & Fittings): _30 Ft Total-150 Ft Pipe Sizing: Based On 2010 CPC Chapter 12 Fuel Piping, Section 1209.4 & 1217.3 Sizing Equations Utilizing Mueller Equation For Gas Flow (>1 Psig) And As Follows: Natural Gas Specific Gravity; 0.667 Pipe ID (1-Inch PE, SDR 11, (attachment 4); 1.075 In. Residual Pressure Calculation (attachment 2): Length; Loop To Building Regulator -150 Ft Gas Flow Rate; 2315 SCFH Residual Pressure @ Building Regulator; 1.0 PSI E) 1-foch Building Supply Lateral Maximum CFH Capacity: Service Pressure: 3.0 PSI, Design Pressure Drop: 2.0 PSI Total Developed Length: Loop To Building Regulator: 120 Ft Equivalent Length (Valves & Fittings): _30 Ft Total-150 Ft Pipe Sizing: Based On 2010 CPC Chapter 12 Fuel Piping, Section 1209.4 & 1217.3 Sizing Equations Utilizing Mueller Equation For Gas Flow (>1 Psig) And As Follows: Natural Gas Specific Gravity; 0.667 Pipe ID (1-Inch PE, SDR 11.5, (attachment 4); 1.075 In. Maximum Allowable Connected Load (attachment 3): Length; Loop To Building Regulator -150 Ft SCFH Gas Flow Rate; 2567 Attachments: ® Attachment 1; (E) 4-inch Distribution Loop Residual Pressure Calculation © Attachment 2; (E) 1-inch Building Service Lateral Residual Pressure Calculation © Attachment 3; (E) 1-inch Building Service Lateral Maximum CFH Capacity Calculation ® Attachment 4; PE Pipe Data Sheet Reference: PPI Polyethylene Design Handixwk Gas Flow .Hich Fr3ssu.''s Gas Fiow P). \-Si sr ^•r'lr•l•:-l^5.^ 111/ i h ref. Mueller equofion for gos fbw (>lpsig) 2826Di"" r (Pi+ 14.7)--(P2+14,7) Q = So 0.425 2 , 0,57? ] inforn-ation Date Project Engineer Name Comments 05-15-2013 Upper Deck Tl - LEGOLAND, Califomia RJones/exp U.S. Services Inc. (E) 4-INCH DISTRIBUTION LOOP - RESIDUAL PRESSURE CALCULATION (including additional Tl gas demand); Utilizing Sizing Equations per CPC section 1217.3 Do 0 Pipe Outside Diameter, in DR 0 Dimension Ratio Sg 0.667 Specific Gravity Lg 3036 Length, ft <4 iViA=M FROM METER + 1/2 DiSTANCS OF LOOP Result Calculated for: P2 D, 3.71 Inside Diameter, in Q 14772.3 Flow Rate, scfh Pi 5.0 inlet pressure, psig P2 3 outlet pressure, psig <t— TOTAL GAS DEMAND INCLUDING NEV¥ LOAD RESIDUAL MAIN/LOOP PRESSURE AVASLABLE IH DiSTRlBUT!0?i Reference: PPI Polyethylene Design Handbook Gas Flow Hich Pressure Gas i^lovj IM ^si a .s-nii-h-l n t. I i. ref. Mueller equoiion for gos flow (>lpsig) 0.425 (P, +14,7)2. (P2+14,7)2 Inrormstion Date Project Engineer Name Comments 05-15-2013 Upper Deck Tl - LEGOLAND, Califomia RJones/exp U.S. Services Inc. (E) 1-lNCH BUILDING SUPPLY LATERAL - RESIDUAL PRESSURE CALCULATION (Including additional Tl gas demand); Utilizing Sizing Equations per CPC section 1217.3 'ZTiZD'.SS Do DR Sg Lg 0 Pipe Outside Diameter, in 0 Dimension Ratio 0.667 Specific Gravity 150 Lengtli.ft Result Calculated for: P2 D| 1.075 Inside Diameter, in Q 2315 Flow Rate, scfh <|— Pi 3.0 inlet pressure, psig-4~ P2 1 outlet pressure, psig - CURRENT GAS DEMAND RESIDUAL PRESSURE AVAILBLE iN DivS rr^JBUTiCH LOOP -RESIDUAL PRESSURE AVAILABLE @ BUiLDlRG ^ n ^ //% /\ ^ Reference: PPI Polyethylene Design Handbook Gas Flow Hich Fressu's Gas Fiov,' PI. x-sui s-pin,-]NsT n 1:11-. ref. MueSer equofion for gos flow (>lp£ig) Sc. 0.425 Inforp-iaiioi' Date Project Engineer Name Comments 05-15-2013 Upper Deck Tl - LEGOLAND, Califomia RJones/exp U.S. Services Inc. (E) 1-lNCH BUILDING SUPPLY LATERAL - MAXIMUM CFH CAPACITY CALCULATION (Including additional Tl gas demand); Utilizing Sizing Equations per CPC Section 1217.3 Do 0 Pipe Outside Diameter, in DR 0 Dimension Ratio Sg 0.667 Specific Gravity Lg 150 Length, ft r^eSUi.. Calculated for: Q Di 1.075 Inside Diameter, in Q 2567.44 Flow Rate, scfh -sf — ^^AXffViUfVj COWfJECTED LO^D Pi 3.0 inlet pressure, psig P2 1.0 outlet pressure, psig .^TTpnnrnBni PERFORMANCE PIPE A DiYism OF CHIVHON PHILLIPS CHEMICAL Comm LP CTS = Copper lube Size] 1/2" 7 0.625 0.09 100 6.5 1,000' 30'V44V6" 12 12,000' 26 312,000' 1" 11.5 1.125 0.099 76 14 500' 30742711' 8 4,000' 26 104,000' IPS = Iron PipeiSize Z2 C. t 5 I O i i i iOiTi!!', / ' / • 3/4" 11 1.05 0.095 : 80 12 500' 30"/44710'' 7 3,500' 26 91,000' 1-11 1.315 0.12 • 80 19 500' 30"/44712" 6 3,000' 26 78,000' 1 1/4" 10 1.66 0.166 89 33 500' 48"/72"/7-1/2" 12 6,000' 7 42,000' 1 1/2" 11 1.9 0.173 80 40 500' 48"/75"/8-1/2" 8 4,000' 7 28,000' 2" 11 2.375 0.216 80 63 500' 52"/78"/13'' 7 3,500' 7 24,500' 3" 11 3.5 0.318 80 136 500' 70"/96723-3/4" 4 2,000' 6 12,000' 3" 11.5 3.5 0.304 76 13i 40' soft bundles 50 2,000' 14 28,000' 3" 11.5 3.5 0.304 76 13i 500' 70796723-3/4" 4 2,000' 6 12,000' 4" 11 4.5 0.409 80 225 500' 70"/93"/41" 2 1,000' 6 6,000' 4" 11.5 4.5 0.391 76 217 40' soft bundles 29 1,160' 14 16,240' 4" 11.5 4.5 0.391 76 217 600' 70"/93"/49-1/2" upright 1,160' 12 7,200' 4" 11.5 4.5 0.391 76 217 1,000' 84"/116"/49" upright 1,160' 8 coils 8,000' 6" 11.5 6.625 0.5:6 76 471 40' soft bundles 13 520' 14 7,280' 6" 11.5 6.625 0.5:6 76 471 500' 84"/120"/50" upnght 520' 8 coils 4,000' 6" 13.5 6.625 0.49;i i 64 407 40' soft bundles 13 520' 14 7,280' 6" 13.5 6.625 0.49;i i 64 407 500' 84"/120"/50-upright 520' 8 coils 4,000' 8" 11.5 8.625 0.75' 76 798 40' soft bundles 9 360' 10 3,600' 8" 13.5 8.625 0.63S, 64 690 40' soft bundles 9 360' 10 3,600' 12" 13.5 12.75 0.944 64 1507 40' bulk packs 8 joints/layer 320' 6 1,920' This product flyer is Intended for reference purposes. It should not be used in place ofthe advice from a licensed Professional Engineer. Pressure Rating is based on an operating temperature of 73°F per 49 CFR 192. Pipe weights are calculated in accordance with PPI TR-7. Nominal OD and Minimum wall plus 6% is used in estimating fluid flow. Actual ID will vary. When designing components to fit the pipe ID, refer to pipe dimensions and tolerances in the applicable pipe manufacturing specification. L Bulletin PP 313 | December 2012 www.performancepipe.com © 2012 Chevron Phillips Chemical Company LP Perfomiance Pipe, a division of Chevron Phillips Chemical Company LP | 5085 W. Park Blvd | Suite 500 | Piano, TX 75093 j Phone:800-527-0662 | Fax; 972-599-7329