Loading...
HomeMy WebLinkAbout1 LEGOLAND DR; ; CB140375; Permit04-03-2014 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plumbing/Mechanical/Electrical (PME) Permit Permit No:CB140375 Building Inspection Request Line (760) 602-2725 Job Address: 1 LEGOLAND DR CBAD Permit Type: PME Status: Parcel No: 2111000900 Lot#: 0 Applied: Entered By: Reference #: Plan Approved: PC #: Issued: Inspect Area: Project Title: LEGO- GREASE INTERCEPTOR 50 GALLON- FOR FUTURE CHURRO TRAILER - LOCATED IN GARDEN AREA ISSUED 02/18/2014 RMA 04/03/2014 04/03/2014 Applicant: KMP PLUMBING 435 S CEDROS AV SOLANA BEACH CA 92075 619-259-9300 Owner: LEGOLAND CALIFORNIA LLC <LF> PLAY U S ACQUISI c/o PROPERTY TAX SERVICE CO POBOX 543185 DALLAS TX 75354 Plumbing Fees Electrical Fees Mechanical Fees Other PME Fees $158.00 $0.00 $0.00 $300.00 TOTAL PERMIT FEES $458.00 Total Fees: $458.00 Total Payments To Date: $458.00 Balance Due: $0.00 Inspector: FINALAPPROVAL Date: //' A / ' ^ / Clearance; NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refen'ed to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required infonnation with the City Manager for processing in accordance with Carisbad IVIunicipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or sen/ice fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otheiwise expired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: nPLANNING nENGINEERING IZlBUILDING •FIRE •91 EALTH •HAZMAT;APCD CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov A i www.carisbadca.gov (j N/V~' PlanCheckNo. (^/^/^jTf Est. Value Plan Ck. Deposi^ Date SWPPP JOB ADDRESS C56AQ r# f#oF SUITE«/SPACE*/UNiT« CT/PROJECT # # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Areafs) In &AAiO£/0 /f^^ EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YESfltf N0| I AIR CONDITIONING YES I I NO I I FIRESPRINKLERS YES I |NO| I APPUCANT NAIVIE (Primary Contact) APPLICANTNAME ^Secondary Contact; ADDRESS ADDRESS 3. C(^C»2.toS hViS CITY STATE ZIP CITY STATE PHONE FAX PHONE 7.^ - <Z)3t g, FAX EMAIL PROPERTYOWNER NAME CONTRACTOR BUS. NAME ADDRESS ADDRESS CITY STATE ZIP STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL , ARCH/DESIGNErt NAME & ABPRESS j STATE UC # ICA _ , CLASS- /• CITY BUS. LIC.# 'X'lH IIP T^f \l(?70 7aD ;r, improve, demolish or repair any struct*^ prior to its issuance, also requires the its issuance, also requires the with Section 7000 of Division 3 ofthe a permitsubjects the applicant to a Workers' Compensation Declaration: / irerefsy affirm under penalty ofperjuiy one of the foiiowing dedaiations: C I have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance _ Policy No. Expiration Date This section need not be completed if the pemiit is for one hundred dollars ($100) or less. 1x1 Certificate of Exemption; I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Califomia. WARNING: Failure to secure workers'CBfflpeM!itiSI^(=5>9rage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, dam^tc^aip^eyi^ fo^iy^ytioi^iWB^bf the Labor code, Interest and attomey's fees. DATE • AGENT DATE ^ ~/ff- • • / hereby affirm fhaf / am exempt from Contractor's License Law for the foiiowing reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the stmcture is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to constmct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contracior's License Law). I I I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. QYes I iNo 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): » 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of woik): ) PROPERTY OWNER SIGNATURE QAGENT DATE THIS SECTION FOR NON-RESIOENTIAL BUiLDING PERMITS is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No Is the fadlity to be constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address CERTIFICATION I certif that I have read ttie appikation and state thatthe above Infbimation is conectand thatthe informatton on the plans is accurate. I agree to complywith all CHy ordinances and State lave relating to building construction. I hereby authorize representative of the City of Carisbad to enter upon the above mentbned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required fbr excavations over 5'0' deep and demolfon or constnjction of structuies over 3 stories in height. EXPIRATION: Every permit issued by the Building Offteial under the provisions of this Code shall expire by limitation and become null and void if the building or wrk authorized by such pennit is not commenced within 180 days from the date of such perniit or if the buikJin^or wrk authorized by such pennit is suspended or abandoned at any time after the vioik is commenced for a period of 180 days (Sectbn 106.4.4 Unifonn Building Code). APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY If a Certificate of Occupancy will be requested at final inspection. m- m c- r € t a } Fax (760) 602-8560, Email buildinq(5)carlsbadca.qov or Mall the completed form to City of Carisbad, Building Division 1635 Faraday Avenue, Carlsbad, Califomia 92008. C0#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICKUP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) MAILTO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) IVIAIL / FAX TO OTHER: ASSOCIATED CB#- NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION vefAPPLICANT'S SIGNATURE DATE Inspection List Permit#: CB140375 Type: PME Date Inspection Item 11/19/2014 29 Final Plumbing 11/19/2014 29 Final Plumbing 10/22/2014 29 Final Plumbing 04/04/2014 21 Underground/Under Floor Inspector Act Rl PD AP PB NR MC AP LEGO- GREASE INTERCEPTOR 50 GALLON- FOR FUTURE CHURRO TRAI Comments Ttiursday, November 20, 2014 Page 1 of 1 I -1' y - V" CITY OF ^T^^^^ INSPECTION RECORD Building Division 0 INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB 0 CALL BEFORE 3:30 pm FOR NEXT WORK DAY iNSPECTION m FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carlsbadca.gov/Buildinq AND CLICK ON "RequestInsoection" OATE: 4^3Z/V CB140375 1 LEGOUND DR LEGO- GREA.SI-: \n 11.\H ;| | M ( )K 50 GAI 1 ON- FOI? nil I ll^r Cl (I II^KO 1 l^AII FR I^OCArEl) IN (-,AWI )I:N AF'I A F^ME Lot# KMPI'LUMRING IF "YES" IS CHECKED BELOW THAT DIVISION S APPROVAL IS REQUIRED PRIOR TO REQUESTING A FlNAL BUILDING INSPECTION. IF YOU HAVE ANY QUESTIONS PLEASE CALL THE APPLICABLE DIVISIONS AT THE PHONE NUMBERS PROVIDED BELOW. AFTER ALL REQUIRED APPROVALS ARE SIGNED OFF- FAX TO 760-602-8560. EMAIL TO BLDGIN$PECTIONS@CARLSBADCA.GOV OR BRING IN A COPY OF THIS CARD TO: 1635 FARADAY AVE.. CARLSBAD. CA 92008. BUILDING INSPECTORS CAN BE REACHED AT 760-602-2700 BETWEEN 7:30 AM - 8:00 AM THE DAY OF YOUR INSPECTION. NO YES Required Prior to Requesting Building Final If Checl<ed YES Date Inspector Notes / Planning/Landscape 760-944-8463 Allow 48 hours y CM&I (Engineering Inspections) 760-438-3891 Call before 2 pm y Flre Prevention 760-602-4660 Allow 48 hours Type of Inspection Type of Inspection CODE # BUILDING Date inspector ^^^^^^V^V^^d^^S^^^^^H Date inspector #11 FOUNDATION #31 • ELECTRIC UNDERGROUND DUFER #12 REINFORCED STEEL #34 ROUGH ELECTRIC #66 MASONRY PRE GROUT #33 • ELECTRIC SERVICE DTEMPORARY • GROUT • WALL DRAINS #35 PHOTOVOLTAIC #10 TILTPANELS #39 FINAL #11 POURSTRIPS CODE # MECHANICAL #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS & PIPING #14 SUBFRAME • FLOOR • CEILING #44 • DUCT & PLENUM • REF. PIPING #15 ROOFSHEATHING #43 HEAT-AIR COND. SYSTEMS #13 EXT. SHEAR PANELS #49 FINAL #16 INSULATION CODE # COMBO INSPECTION #18 EXTERIORUTH #81 UNDERGROUND (11,12,21,31) #17 INTERIOR UTH & DRYWALL #82 DRYWALLEXT UTH, GAS TES (17,18,23) #51 POOLEXCA/STEEL/BOND/FENCE #83 ROOFSHEATING, EXT SHEAR (13,15) #55 PREPUSTER/FINAL #84 FRAME ROUGH COMBO (14,24,34,44) #19 FINAL #85 T-Bar (14,24,34,44) CODE # PLUMBING Date Inspector #89 FINAL OCCUPANCY (19,29,39,49) #22 • SEWER & BL/CO • PL/CO FIRE Date Inspector #21 UNDERGROUNDJZtiVASTE OWTR #24 TOPOUT DWASTE DWTR 1 { A/S UNDERGROUND VISUAL #27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO #23 DGASTEST • GAS PIPING A/S UNDERGROUND FLUSH #25 WATER HEATER A/S OVERHEAD VISUAL #28 SOURWATER •) A/S OVERHEAD HYDROSTATIC #29 FINAL A/S FINAL ?coDE# STORMWATER F/AROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL #603 FOLLOW UP INSPECTtON FIXED EXTINGUISHING SYSTEM ROUGH-IN #605 NOTICETO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL #609 NOTICEOFVIOUTION MEDICAL GAS PRESSURETEST #610 VERBALWARNING MEDICAL GAS FINAL SEE BACK FOR SPECIAL NOTES EsGil Corporation In (PartnersHip •witH government for (BuiCding Safety DATE: April 1, 2014 • APPLICANT • JURIS. JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLANCHECKNO.: 14-0375 SET; III PROJECTADDRESS: 1 Legoland Dr. PROJECT NAME: water line & hydro mec hanical grease interceptor stub out only. ^ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. [~~| The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. r~| The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. r~] The applicant's copy of the check list has been sent to: Vance Miller, of KMP Plumbing, '135 So. Codros Ave. SolanaBeach, CA, 92075 EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Vance Miller—Tolophono if: 858 259 9300 Fax #: 858 258 0318 Date contacted: (by: ) Email: vancem(5)kmpplumbingreem Mail Telephone Fax In Person • REMARKS: By: Glen Adamek Enclosures: EsGil Corporation 13 GA • EJ • MB • PC 3/25/2014 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGii Corporation In (Partnership •with government for (BuiCding Safety DATE: 3/18/2014 •APPLICANT v^^URIS. JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLANCHECKNO.: 14-0375 SET: II PROJECT ADDRESS: 1 Legoland Dr. PROJECT NAME: water line & hydromechanical grease interceptor for future churro trailer. I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Vance Miller, of KMP Plumbing, 435 So. Cedros Ave. SolanaBeach, CA, 92075 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Vance Miller Telephone #: 858-259-9300 Fax #: 858-258-0318 Date contacted: ^ - |<5 (b^^^) Email: vancemt^kmpplumbing.com j^Mair^ Telephone^ Fax In Person • REMARKS: By: Glen Adamek Enclosures: EsGil Corporation • GA • EJ • MB • PC 3/10/2014 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 14-0375 3/18/2014 NOTE: The Items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers ofthe items are from the previous check list and may not necessarily be in sequence. THE NOTES IN BOLD FONT ARE CURRENT REMAINING ITEMS. • GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business & Professions Code. 3. Please provide notes on the drawings stating.' "A separate permit is required for installing the future churro trailer." 4. Please address on the drawings that this permit package does not include required electrical service for the proposed future churro trailer. This permit does not include electrical required for future churro trailer. A separate permit is required for electrical for future churro trailer. PLUMBING (2013 CALIFORNIA PLUMBING CODE) 6. Please clearly address on the drawings that this permit package does not include required non-grease waste drainage system for the proposed future churro trailer. Please show separate waste connections for the grease waste and the non-grease water drainage systems from the food trailers. 7. As per CPC, Table 1014.2.1 for the 3 inch waste for the future churro trailer show the minimum 60 gpm grease Interceptor as per the maximum allowed gpm flow through a 3 inch horizontal waste line with VA inch per foot slope. Carlsbad 14-0375 3/18/2014 Please correct. Please provide the grease interceptor sizing calculations. CPC 1014.0 The proposed hydromechanical grease interceptor seems to be undersized of trailer grease waste. 8. As per the data provided for the proposed Zurn GT2700 grease interceptor does not comply with the Exception to CPC, Section 1014.2 for an "integral flow controls or restricting devices Installed in an accessible location in accordance with the manufacturer's installation instructions." Note the manufacturer's required flow control devices at each plumbing fixture drain. Please provide detail of the required vented flow control valve for the proposed hydromechanical grease interceptor. Please provide details. 9. See item # 8 just above. Please provide installation instructions for the proposed hydromechanical grease interceptor and vented flow control valve. 10. The drawings show the water line to be connected to the near by building water supply after the backflow device for the building. Please provide revised building water line sizing calculations for the existing building plus the proposed future churro trailer, including the added water demand and the added water pipe length. This could make the existing water lines in the existing building undersized. Please address. Please provide details of the water line connection and required backflow protection. 11. A complete review of the installation of proposed grease interceptor will be done when complete corrected plans & details of installation are provided. 12. Please clearly note the water connection, grease waste connection, sewer waste connection, gas connection, and electrical connection are not located below the proposed future trailer's footprint. Detail the support ofthe plumbing vent for the proposed grease interceptor. Note the plumbing vent stack may not be connected to the trailer. . ADDITIONAL 13. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 14. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please brieflv describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: • Yes • No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Glen Adamek at Esgil Corporation. Thank you. EsGil Corporation In (Partnership -with government for (BuiCding Safety DATE: 3/4/2014 • APPLICANT a<)URis. JURISDICTION: Carlsbad • PLANREVIEWER • FILE PLANCHECKNO.: 14-0375 SET: I PROJECTADDRESS: 1 Legoland Dr. PROJECT NAME: water line SB hydromechanical grease interceptor for future churro trailer. I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. XI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Vance Miller, of KMP Plumbing, 435 So. Cedros Ave. SolanaBeach, CA, 92075 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. IX| EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Va^nce Miller Telephone #: 858-259-9300 Fax #: 858-258-0318 Date contacted: (by:^^) Email: vancem(5)kmpplumbinq.com Mail ixfelephone Fax In Person • REMARKS: By: Glen Adamek Enclosures: EsGil Corporation • GA • EJ • MB • PC 2/21/2014 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 14-0375 3/4/2014 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLANCHECKNO.: 14-0375 JURISDICTION: Carlsbad REMARKS: water line & grease interceptor for future churro trailer. DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: 2/18/2014 ESGIL CORPORATION: 2/21/2014 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Glen Adamek COMPLETED: 3/4/2014 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval ofthe plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. Carlsbad 14-0375 3/4/2014 • GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued. Business and Professions Code. The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued. 3. A separate permit is required for installing the future churro trailer. 4. This permit does not include electrical required for future churro trailer. A separate permit is required for electrical for future churro trailer. PLUMBING (2013 CALIFORNIA PLUMBING CODE) 5. Provide a plumbing material schedule on the plans describing the following systems: Potable water piping and the drain, waste, and vent piping. 6. Please show separate waste connections for the grease waste and the non- grease water drainage systems from the food trailers. 7. Please provide the grease interceptor sizing calculations. CPC 1014.0 The proposed hydromechanical grease interceptor seems to be undersized of trailer grease waste. 8. Please provide detail of the required vented flow control valve for the proposed hydromechanical grease interceptor. Please provide details. 9. Please provide installation instructions for the proposed hydromechanical grease interceptor and vented flow control valve. Carlsbad 14-0375 3/4/2014 10. Please provide details of the water line connection and required backflow protection. 11. A complete review of the installation of the proposed grease interceptor will be done when complete corrected plans and details ofthe installation are provided. 12. Detail the support of the plumbing vent for the proposed grease interceptor. Note the plumbing vent stack may not be connected to the trailer. • ADDITIONAL 13. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 14. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please brieflv describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: • Yes • No 15. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to periderm the plan review for your project. If you have any questions regarding these plan review items, please contact Glen Adamek at Esgil Corporation. Thank you. Carlsbad 14-0375 3/4/2014 [DO NOT PAY- THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Glen Adamek PLANCHECKNO.: 14-0375 DATE: 3/4/2014 BUILDING ADDRESS: 1 Legoland Dr. BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code Cb By Ordinance BIdg. Permit Fee by Ordinance Plan Checl< Fee by Ordinance • Type of Review: • Complete Review •Repetitive Fee ^ Repeats Based on hourly rate • Other ^ Hourlv EsGil Fee $375.00 • Structural Only $100.00 Hrs. @ $300.00 Connments: hourly for 3 hours at $100.00 per hour Sheet 1 of 1 macvalue.doc + CB140375 1 LEGOLAND DR I FGO- GREASE INTERCEPTOR K/I^IH f/N(^i02> Final Inspection required by: a Plan a CM&I • Fire s^i/km la P •ISSUED •cv. A^^proved Date By BUIU3ING PLANNING ENGINEERING FIRE Expedite? Y N AFS Checked by: HazMat APCD Health Forms/Fees Sent Rec'd Due? By Encina Y N Fire y N HazHealthAPCD y N PE&M y N School y N Sewer y N Stormwater y N Special Inspection y N CFD: Y N LandUse: Density: ImpArea: FY: Annex: Factor PFF: Y N Comments Date Date Date Date Building Planning Engineering Fire Need? • Done • Done • Done • Done