Loading...
HomeMy WebLinkAbout1 LEGOLAND DR; CASTLE HILL; CB980207; Permit\ r- \ ' '\ \ vooOl90Co BU.ILDING P E R M I '1' ·· '. Pe-rmi t N:6: CB98'0Z07 Proje·ct No: A~809-279 Development No: 01/2 9/9,8 09 :'04 · Page .1 of ,;t · Job Address: .. 1 LEGO. DR Per.mi t Type: 'COMMERCIAL BUILDING Parcel No: Valuation: 166,204 suite:· Lot#: Occupancy Gr·oup: Referen<;::e#: Construs=;tion Type: VN .Status:_ IS·,SUED. Description: "CAS-TLE .HILL'; DUNGEON ICE CREM : 78~ SF PLAN CH:ECK 97-33'56 -· · · Applied: 01/27 /98 350ll 01/~ I®§he)l, 0 !li:Y 2 9 /9 8 . ,Enteroo-P®rV-:· MDE4958 .. QO 31·0 44.5.3_,..0·1.oo. · FIN~~APPROVAL. (16 orx=·~r:2· zi:71 llNSP._.~----#-\i._L: : _-· ,. . .,~ CLEARA>~ c:; __ . ______ _,, __ .. PW m -U,:..:: WWW:. WCU:..:...;:,:;;. 1 AWWWl/iQS..-~ CiTY OF CARLSBAD. · 'l,,075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-116,I: ·• City of Carlsbad Inspection Req_uest For: 2/22/99 Permit# CB980207 Title: CASTLE HILL DUNGEON ICE CR.EM Description: 784 SF PLAN CHECK 97.:.~355 Type: COM Sub Type: Job Address: 1 LEGO DR Suite: Lot Location: ~PPLICANT : ADACHI, KYOKO Owner: LEGOLAND CARLSBAD .INC <LF> LEGO Remarks: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comments Inspector Assignment: PD ----------- Phone: lnspec~ Requested By: JIM Entered By: CHRISTINE ----------------------·-----,-,----,,--------------------"--'""""""---- Inspection History Date D~scription Act lnsp Comments 2/16/99 89 Final Combo NR PD 1/29/99 89 Final Combo NR PD 8/10/98 11 Ftg/Foundation/Piers PA PD 7/15/98 11 Ftg/Foundation/Piers AP PD 7/15/98 12 Steel/Bond Beam AP PD 6/30/98 11 Ftg/Foundation/Piers AP PD 6/29/98 11 Ftg/Foundation/Piers NR PD 6/29/98 31 Underground/Conduit-Wiring PA PD 6/19/98 31 Underground/Conduit-Wiring AP PD 6/19/98 34 Rough Electric WC PD 6/10/98 11 Ftg/Foundation/Piers AP PD 6/9/98 11 FtgiFoundation/Pi~rs NR PD -SEE MULTIPLE SPECIAL -INSPECTIONS SCANNED SEPARATELY CB972027 IS THE ' . PLAN CHECK N.UMBER FOR MANY OTHER CB'S ALSO SEE ' CB971460(OUTER PARK) CB97146S(ADMfN BLDG) Citv of Carlsbad · Final Building Inspection RECEIVED · 1 I · JAN 2 91999 Dept: Building i:ng'ineetiftg Planning CMWD St Lite Fire CITY OF CARLSBAD NGINEERING DEPARTMENT Plan Check #: Permit#: Project Name: CB980207 CASTLE HILL DUNGEON ICE CREM 784 SF PLAN CHECK 97-3356 Address: 1 LEGO OR Contact Person: JIM PAYTON Plione: Sewer Dist: Water Dist: Date: 1 /29/99 Permit Type: COM Sub Type: Lot: ··········································•·••················································•·•·······•···································•············· Inspected ~ Date 2-, L-~ df!/ . V Disapproved: __ By: Inspected: , Approved: Inspected Date By: Inspected: Approved: Disapproved: __ Inspected Date By: Inspected: Approved: Disc;1pproved: __ ...................................................................... ~·················································,·· ··············· ................ . Comments: -----------------------------'------------------- . CHY Of Carl$bld . ~ ·; ·Final Building Inspection " -.... i'.... .. -, Dept: Building Engineering Planning CMWD St Lite Fire Plan Check#: Permit#: Project Name: CB980207 CASTLE HILL DUNGEON ICE CREM 784 SF PLAN CHECK 97-3356 Address: 1 L!;:GO DR Contact Person: JIM PAYTON Phone: Sewer Dist: Water Dist: Date: 1/29/99 Permit Type: COM Sub Type: Lot: ························································•11!!••········~··~·················································· .. ···········••!••··············· Inspected Date / By: Inspected: . Approved: Disapproved: __ Inspected Date By: Inspected: Approved: . Disapproved: __ ' Inspected Date By: Inspected: Approved: Disapproved: __ ··························································~·····························································~·································· Comments: _____ ---'---------------------.......... -------------- • I ~... CIIY of Carlsbad ~ ·; . Final ·Building Inspection """If"" • Dept: Building Engineering Planning CMWD Plan Check#: Permit#: Project Name: Address: CB980207 CASTLE HILL DUNGEON ICE CREM 784 SF PLAN CHECK 97-3356 1 LEGO DR Contact Person: JIM PAYTON Sewer Dist: Phone: . Water Dist: Lot: Date: Permi{Type: . Subtype: 1/29/99 COM • I I •• I I 11 I I I I 11 I I Ill II II I I I I I I I I Ill 11111 II Ill I I I I I ii I Ill I II II II I I I I I I ii I I 1111 II Ill I I I I I I I I 1,1 I 111111!'1 Ill I I Ill I II Ill Ill a'111 I I I II~ I I 111 I I II II I II I 11 I I I I II II 111111 Inspected ~ Date By: Inspected: 1---1~ q::1 Approved: ,_,-Oisapproved: __ Inspected Date By: Inspected: Approved: Disapproved:_. _ Inspected Date By: ·ln$pected: Approved: Disapproved: __ ····················································································································~········~···········••!'••••··········· Comments:-------,------,,----~----------'----=------,...---- CIIJ of Carlsbad · Final Building lnspacuon Dept: Building Engineering manning:} CMWD St Lite Fire Plan Check#: Permit#: Project Name: CB980207 CASTLE HILL DUNGEON ICE CREM 784 SF PLAN CHECK 97-3356 Address: 1 LEGO DR Contact Person: JIM PAYTON Phone: Sewer Dist: Water Dist: Date: 1 /29/99 · Permit Type: COM Sub Type: Lot: ................................................................................................................... ~······································· Inspected vt1? Date . ~. ~-QqApproved: / Disapproved: __ By: Inspected: Inspected Date By: Inspected: Approved: Disapproved: __ Inspected Date By: Inspected: Approved: Disapproved: ____ ................................................................................•.•........................................................................ , Comments: ______________________ ---'-______ ....;.... ___ ___ City of Carlsbad · Final Building Inspection :-"" :_· ·~ -l ·1999 1 ••• _' .· --_ .----~ -- Dept: Building Engineering Planning CMWD St Lite CFlriP Plan Check #: Date: 1/29/99 Permit#: CB980207 · Permit T,ype: COM Project Name: CASTLE HILL DUNGEON ICE CREM Sub Type: 784 SF PLAN CHECK 97-3356 Address: 1 LEGO DR tot: Contact Person: JIM PAYTON Phone: Sewer Dist: ' Water Dist: ·i;;:~:~: ............. : ............... ~::~:~~:· .. ··;·;·;-· .......... :~~:~:~: .. ··/· .. ~;~~:::~~~: .......... . Inspected Date By: Inspected: ·Approved: Disapproved: __ Inspected .Date By: Inspected: . Approved: Disapproved: __ •II I I 111111III111111 I 1111 I I I I I I I I 11111!1 I I I I I I I I I 11 I I 11 I 11 I I 11 I I I I II I I I II II Ill l"I II I 111 I I I 1111 II II I II I I I I I I I II Ill I I I I II I I I I I I I I I Ill I 11111 II I I a II I I I I Ill II II II Comments: _________________________________ _ l •J Information • .. ToBuildOn ,· Page_1_oL.L Engineering • Consulting • Testing INSPECTION REPORT PROJECT (Name),__..Le__,G:,c)~~f,...:.~~=-i11---cuENT_-=L~e-Gi~o _._{-"-'~~d--- oATE __ ,_-_2,, __ ~=---G'c,_9_.__ __ Architect. __ ~\--· ...... { _EJ-=--· --'-"'--=--------- Engineer_· __ ~CY\'--'-_,__c:{--'--_,_(V)_.,_· ----'-----'-- Contractor. __ =8_..,,.e...X)-+--.,_C.-~--------'------- INSPECTION MAT'LSAMPLING QTY _OSHPD __ Concrete Cylinders -- _OSA __ Cement -- __ specialty __ Mortar Samples --__ Mechanical __ Grout Samples --__ Electrical ___ Masonry Prisms --__ Roofing __ Ma~onry Block -- __ concrete __ Fireproofing --__ Masonry __ Units (block or brick) . . _k... Struct Steel __ Asphalt Concrete --__ Prestress Cone _. _Roofing -- __ Pile Driving ___ Reinf. Steel __ Fireproofing _. _Steel -- __ Waterproofing __ H.S. Bolts -- __ Non-Destructive __ Tendon (PT Strands) __ Soils Technician __ Other -·-- __ Batch Plant __ Other -- __ Bolt Pull-Out __ Other -- REMARKS (Address) __ --,-____ _,_._ G-z.1s3A-u. c; . REPORT NO. ___ --c=::,...._'7...,,0e....,2...._J¢~:L:-· ---~-~_fa'_Z-_ Building Permit No. _______ 4__,__,<f..__-.,_ __ 2,_..,...,0=7__.__ ____ _ Plan FileNO,-----'------'------'------ Govt. Contract No. _____________ ..;...._ OSA-or ~H~ # . ~ _ 1 Other LJA<-77-e }-};) ) :i>v Y..5ec>Y\ j te (ps,p. MATERIAL DESCRIPTION INSPECTION CHECKLIST _ Rinf.: Rebar .,kL Plan & Specs ___ Rinf.: W.W.F. _ Clearances ___ . Rinf.: Tendons _ Positions _ Cone.: Mix #/psi _Sizes _ Cone.: Mix #/psi _Laps _ Cone.: Mix #/psi _ Future Continuity #/psi _ Grout: Mix #/psi· _ Consolidation _ Mortar: Type/psi '" _ Mortar Batchinn ·-Units: Block _ Electrode Storage _Units:~ck Torque Applied C+..:-Ae:, I'< _}!_ Steel · ,....:; i-l'V'\ · ___ . H.S. Bolts __ Metal DeckiQa_ • . X· Electrodes L:.. c -P.X X. ·~_:, ,~\ - _ Fireproofing . .l5l_ Other ASf'M. 8:¾ _ Corrective action required __ _ Corrections-completed CERTIFICATION OF COMPLIANCE: To the best of our knowledge, all of the reported work, unless otherwise noted, substantially complies with approved plans specifications and applicable sections of the building codes. This report covers the locations of'the work inspected only and does not constitute engineering-opin- ion or project control. · CERT. NO. f:g ]() 3 DATE_-'-/_-....,L=--<f---t]'--o._1 _______ _ PSI-B-900-170(2) l iJ Information I:!. • .. ToBuildOn Page_1_of _j_ Engineering • Consulting • Testing INSPECTION REPORT CLIENT _ __..Le"""-->G.-;O.,...__ __ _ DATE,...__-+-)_-_l,ot:...7..:....-_5._4-1--- Architect __ --1--f-±--1--.....;0=--+f{ ___________ ____ Engineer __ __,_}'YJ_~g._.=-'-W)..:....+-_ ------"--------- Contractor. __ :g~~?,......_0=--------- INSPECTION MA T'L SAMPLING. QTY __ OSHPD __ Concrete Cylinders · --_OSA __ Cement --__ Specialty ___ Mortar Samples --__ Mechanical __ Grout Samples -- _ Electrical __ Masonry Prisms --__ Roofing ___ .Masonry Block --, __ Concrete __ Fireproofing --__ Masonry __ Units (block or brick) -- ....JL.Struct Steel ___ Asphalt Concrete --__ Prestress Cone __ Roofing --__ Pile Driving ___ Reinf. Steel __ Fireproofing __ Steel -- __ Waterproofing ___ H.S.-Bolts -- __ Non-Destructive __ Tendon (PT Strands) __ Soils Technician . __ Other __ Batch Plant __ Other--- __ Bolt Pull-Out __ Other -- REMARKS PROJECT (Name ) _____ \=e..-"---C.-=o__.(...,_~""-'----=d=-=-· __ (Address) _ __,..----,------- . CL«2]_$BAJ) ' G . REPORT NO. __ ...,,,7'--"'e;.._:z__o'--"-2 ...... < ...... ~..._--~.L..~.._1/_ Building Permit No. ----,-9+_ ..... e ..... · --t;..;;2""-""0~7---,-. -- Plan File No. _____________________ _ Govt. Contract No. ______________ _ OSAorfoSHP.D #}7. r· ~ , Other G,tlz-~ H; l· j):" ~o t--~ Ge:: ( Roi6 MATERIAL DESCRIPTION INSPECTION CHECKLIST _ Rinf.: Rebar ?2._ Plan & Specs _. _ Rinf.: W.W.F. _ Clearances i _ Rinf.: Tendons. _ Positions _ Cone.: Mix #/psi _Sizes _ Cone.: Mix #/psi -.-Laps _ Cone.: Mi1< #/psi _ Future Continuity #/psi _ Grout: Mix #/psi _ Consolidation ___ Mortar: Type/psi _ Mortar Batching _ Units: Block _ Electrode Storage -. _ Units: k . _ Torque Applied __,.,.k.. Steel . 1" h"I P.:Soo /-( _H.S.Bolts _ Metal Decki~ . ~ Electrode~ -ZC,x;,x; ~&I{! _. Fireproofing _. Other _ Corrective action required __ --_ Corrections completed CERTIFICATION OF COMPLIANCE: To.the best of our knowledge, all of.the reported work, unless otherwise noted, substantially complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work· inspected-only and does not constitute engineering opin- ion or project control. · INSPECTOR NAME 'b B:::r\~~ '9-_ . ~ (Prt~~ · INSPECTOR SIGNATUR.:l-,)~ +a_,~ PSI-B-900·170(2) CERT. NO. °{'37[j 5. DATE_-"'l-_.;;>::,,<..7..,__-__,_J'-15': _______ _ l •J Information · I!! • ~ToBuild On Page_1_of-\- Engineering • Consulting • Testing lNSPECTION REPORT · . · PROJECT (Name) L.c:G,a) ~d CLIENT ___ G:==---ac,_D.__ __ _ DAT ..... E_ ....... l_--Z...=-=~-7_,_4 __ _ (Address)--,,....----,,------~:...__ · ~ls:3~u . ,,-Ci. REPORT No. :z o. "2-:c:L ~/o9D Architect ___ tl...._..-...a:0=--}>--'(_=------------Building Permit No. ___ _,7',___..~.__-_..,:)"""· ..-0 .... '7+· ___ _ Plan File No, _______________ _ . Engineer __ __.'\IV}_....;.....;4\--=-.... \r--"--V\....,__ ________ _ Govt. Contract No.--------------- Contractor. __ ]3-----=,,,,_M_~C_,,~---'----'----'---OSA-oJ,OS.!i_P.D # . ._ Otherl"'illt:-"w;M~JS":Je~ T& CIUL'4rz INSPECTION __ QSHPD _OSA __ Specialty __ Mechanical __ Electrical __ Roofing __ Concrete __ Masonry -1!...struct Steel __ Prestress Cone __ Pile Driving __ Fireproofing __ Waterproofing __ Non-Destructive __ Soils Technician __ Batch Plant __ Bolt Pull-Out MAT'L SAMPLING __ Concrete Cy)inders __ Cement __ Mortar Samples __ Grout Samples __ Masonry Prisms __ Masonry Block __ Fireproofing • __ \,Jnits (block or brick) __ Asphalt Concrete __ Roofing __ Reinf. Steel __ Steel ___ H.S. Bolts · __ Tendon (PT Strands) __ Other __ Other _____ -___ _ __ Other ______ _ QTY MATERIAL DESCRiPTION INSPECTION CHECKLIST ___ Rinf.: Rebar __ '----'--_& Plan & Specs _____ _ ___ Rinf.: W.W:F. _ Clearances ______ _ ___ Rinf.: Tendons _ _. Positions. ______ _ ___ ·Cone.: Mix #7psi _ Sizes----______ _ ___ Cone.: Mix #/psi _ Laps _____ -'----- --_. Cone.: Mix #/psi _ Future Continuity #/ps.i~· __ _ ___ Grout: Mix #/psi _ Consolidation _____ _ ____ Mortar: Type/psi _ Mortar Batching__,. ___ _ _ Units: Block· _ Electrode Storage ___ _ __ _ Units: Brick _ Torque Applied ____ _ __ ..J52. Steel ¥\S"'twt fr; la ___ . H.S. Bolts----~--- ---_ Metal Deck~ · ~ Electrodes '::-1 o-1-'I, _ Fireproofing __ ..,.. ___ __,;. __ ______ Other _________ Corrective action required __ ----------'-----_ Corrections completed __ _ CERTIFICATION OF COMPLIANCE: To the best of our knowledge,-all of the reported work, unless otherwise noted, substantially complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work inspected only and does not constitute engineering opin- ion or project control. · · INSPECTOR NAME ::u ~7~ ~b (?) :~,~~;,.~~~A SIGNATUA~~~he,...,r CERT. NO. ':{"8:"103 l •1 Environmental • Geotechnical ' ... ~ Construction Page_1_of_ Consulting • Engineering • Testing INSPECTION REPORT PROJECT (Name) '-r:~Q ' l:!J. c:d~ CLIENT· Le:a.z;. t £1. t:::. i) .. (Address) ~~s.a,::t~ (!I:!_. DATE /2 ~ ,2--f% REPORT NO. cSf-702-az. Architect '-'aiL Building Permit No. ~e--2.oz Plan· File No. Engineer ~ ~:o d...:2 Govt. Contract No. OSA or OSHPD # Contractor. 1:cji:--'YL/V-.4,"2...QS ~ V1...0 'ir-t &"h-S Other e.t!.s:n ~ /:1.l'-'--f2r.!. tt..,'2 Cf.12 /I.I I c fl: ·t,,.12:tJ21- INSPECTION MAT'LSAMPLING otv MATERIAL DESCRIPTION INSP.ECTION CHECKLIST __ OSHPD ~Concrete Cylinders _!:f_ ~ Rinf.: Re~auH-1~ ~ e:i.~bo ~ Plan & Specs _OSA __ Cement --__ Rinf.: W.W.F. :><' Clearances ..:i.:._Specialty __ Mortar Samples --__ Rinf.: Tendons ==---Positions __ Mechanical __ Gro1,1t Samples --~ Cone.: Mix #/psi !a:Z."1--'lPP,';, X Sizes __ Electrical __ Masonry Prisms --·-_. _ Cone.: Mix #/psi '>Laps __ Roofing __ Masonry Block --__ Cone.: Mix #/psi _ Future Continuity #/psi ..z:._concrete __ Fireproofing --__ Grout:.Mix #/psi . _;:..:.. Consolidatio __ Masonry ___ Units (block or brick) --__ Mortar: Type/psi -. Mortar Batching __ Struct Steel __ Asphalt Concrete --_. -. Units: Block _ Electrode Storage __ Prestress Cone __ Roofing --__ Units: Brick _ Torque Applied __ Pile Driving __ Reinf. Steel -·--__ Steel __ Fireproofing ___ Ste!:ll --__ H.S. Bolts __ Waterproofing __ H.S. Bolts ·--ME!tal 0ecking .. __ Non-Destructive . ,· __ Tendon (PT Strands) . __ Electrodes -- __ Soils Technician __ Other --__ Fireproofing __ Batch Plant ___ Other -·-. -. _Other . ___ Corrective action required __ __ Bolt Pull-Out . · ___ Other -.-_ Corrections completed REMARKS $".?(.q,1&( l&~nll:TZOtY Pr2-ov1~ 1-od trar f?C AC t?n c;;zc., Z: c2E 41-fZdltO&C,«1, b s aaa;. dbd> ®fVCiUCD:C &:r: m,~ ('A-;77,(?f {flL<,. 2:;,un di f:f'P A-I IC.i.O C! /L££19&d ;:>Aft..t.C>IL A<2PlZtY6 S a,.12., t> IJNG'S"" 1-'.To k,S--o.cr. :rv·z.. ,2.tnN(:qa:-'-1 ,1.-". · sn,z;z.. W,,,$ ~ Jfti'Ci::,¢'2> Si;,d,, i>a-c,PW22, a&& -GIZ~ .J a.141,p t£ .J 4a'1 e seu e ,-rs . > C-L (5?1d,A.(U_ c-:S > r1 ~ i? a, , em-do-?c..rlt;J, >?1 Nh.,T A:<-c:-Qd,-i:>ttv( ::z:p -;-1,..ff) Pa a .,1 c-,---rr/ Pc.....efz!..:S s He-ur$-.S"200 I s. l f Q {z_r:c: J>Z:-LS) ; · $ t D •· 'i:>2:l ";-I,, .3~ 10 .J S$ 2 -on.-3 . ti. ., s s-z.., -on-& '2 • .fn&m-1!1, :z:t> a !lc::a P,:..,4£ t;tp A..I tfZe<::;OIV $L.-QAl,.I ~,K-,1-~z •u;,oo j>!.J l)lS $ £::f&V4'£D ,n a rv I ro&<;rD t4&:::1> tz:OCnro · 4a A.A.fot;n7£ ?L dC,;,Wo7'1..-rr orvtrli}~er o~ f:aVt"l-.(';). --r"-£5.T :i.l.><::i'Z. rn,,rt:nt-q, ~,d2:2,z....Q .~.:!:J.<ST::.. D!.:i!'2-16.::'2 ,"">,.t:1.~&ntf2.?<.. · & 4J O :-t..K.. ?t:,"'lL-t L .4 M f+-f'-.J ~ '!, {=> ~, f-1U4-'rlc., µ ':, ~ CERTIFICATION OF COMPLIANCE: To the best of our knowledge, all of the reported work, unless ot erwise noted, substantially complies with approved plans specifications and applicable sections of the building codes. This report covers the locc1.tions of the work inspected only and does nol'constitute engineering opin- ion or project control. INSPECTOR NAME ~l-f>U:.DL .. :p ~~...,-a)\..~-C,.:, CERT. NO. c,-e~ c.c, 'e,\-~~ ~.,,c,..., ~ INSPECTOR SIGNATURE p__). ~ ';2_ ~ DATE G,-\-i..-'is PSl·B-900·170(2} ___d!: INSPECTION REPORT CLIENT t.-'°2a LJ4:JA.,:D Architect J-lo ':::' Engineer &t itltl,,T7AJ INSPECTION MAT'L SAMPLING _OSHPD __ Concrete Cylinders _OSA __ Cement __ Specialty __ Mortar Samples __ Mechanical ___ Grout Samples __ Electrical __ Masonry Prisms __ Roofing __ Masonry Block 'X' Concrete __ Fireproofing __ Masonry __ Units (block or brick) __ Struct Steel __ Asphalt Concrete __ Prestress Cone · __ .Roofing __ Pile Driving .--· Reinf. Steel __ Fireproofing ___ Steel __ Waterproofing __ H.S. Bolts __ Non-Destructive __ Tendon (PT Strands) __ Soils Technician __ Other __ Batch Plant __ Other __ Bolt Pull-Out __ Other. .. REMARKS QTY --· --- ---·-- -- --· -- ---- ---- -- -- -- -·-- PROJECT (Name) I ta,;,o <-A-e«<l> (Address) &,/!LU; 'e:,AJ> &f. REPORT NO. oG<?: Zo?.O? -. :2,:0 ~ Building Permit No. ___,_2~B,c__r ..,e, .... +"'"'"'---,----------- Plan File N0,-------------------- Govt. Contract No.-------------- OSA-or OSHPD #------------- Other&t~rvt,:: f/rv -"Zc1..v<;,0'?:;?)v~§'"u12Q?f.-.. MATERIAL DESCRIPTION INSPECTION CHE:CKLIST 2:5:_ Rinf.: Rebar Ab/S /b/.,.YJ 2!'.:... Plan & Specs &:a.d-36¥ _ Rinf:: W.W.F. ~ Clearances _ Rinf.: Tendons A. Positions _ Conc.:'Mix #/psi ...a.Sizes _ Cone.: Mix #/psi _Laps _ Cone.: Mix #/psi . ___ Future Continuity #/psi __ _ Grout: Mix #/psi _ Consolidation _ Mortar: Type/psi _ Mortar Batching _ Units: Block _ Electrode Storage _. Units: Brick _ Torque Applied _Steel _H.S.Bolts _ Metal Decking _ Electrodes _ Fireproofing ..)5,_ Other JI.L L-"II 1::!1' \ S-o _ Corrective action required __ _ Corrections completed CERTIFICATION OF COMPLIANCE: To the best of our knowledge, all of the reported work, unless otherwise noted, substantially complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work inspected only and does not constitute engineering opin- ion or project control. · INSPECTORNAMf---P~<-'?. Y~i\J CERT. NO. D:Se>oy S:2 I-~ (PrlntC~ p INSPECTORSIGNATUR~ ~~ PSl-8-900·170(2) DATE 7_-~}-Y 5 l . -, Envwonmental ·,,,,,. f Geotect,n~cal •-• Construction Page_1_of_· Consulting • Engineering • 'Testing INSPECTION REPORT CLIENT Le~ t -d¼--S) · DATE 7-\ 'J-'1:6' Architect_.=LE:::------------------- Engineer ma.a...s:, Q INSPECTION MAT'L SAMPLING QTY _QSHPD __ Concrete Cylinders --__ OSA __ Cement --__ Specialty __ Mortar Samples -- __ Mechanical __ Grout Samples -- __ Electrical __ Masonry·Prisms -- __ Roofing __ Masonry Block -- ½..Concrete ___ Fireproofing -- __ Masonry __ Units (block or brick) -- __ struct Steel __ Asphalt Concrete -- __ Prestress Cone __ R9ofing -- __ Pile Driving __ Reinf. Steel ' __ Fireproofing ___ Steel -- __ Waterproofing __ , H.S. Bolts -- __ Non·Destructive __ Tendon (PT Strands) --· __ Soils Technician __ Other -- __ Batch Plant __ Other -- __ Bolt Pull-Out __ Other -- REMARKS A,..._:t:::, ]:> 0 c N 151.-<;, LI< oC-~ ,sv -C,cJ?I I:\ PROJECT (Name) l a:t-ao LAN~ (Address) C+:+4-LSn•:\l;\ Ct!-, REPORT NO. <-:"9'1':Z en 91... Building Permit No . .,.._ ....,iw.f'?o<..·.-·'2.J-=o'--'1::,,__ _______ .;___ Plan File No. ________________ _ Govt. Contract No.-~--------------- CSA orOSHPD #.------------- Other ¼si:U;i '1 "'·'-:t?v."-'_'2l;J;;;i~ \~ c..a..s;:7"\r:Y'::: MATERIAL DESCRIPTION INSPECTION CHECKLIST i >< Rinf.: Rebar 4c.:,1s -_«.\,z..<.:--=> ~ Plan & Specs \ _ Rinf.: W.W.F. ~ Clearances ___ Rinf.: Tendons ~ Positions __ Cone,, Mix #/p~i ~Sizes __ Cone.: Mix #/psi Y Laps i I __ Cone.: Mix #/psi _. Future Continuity #/psi __ Grout: Mix #/psi _ Consolidation __ Mortar: Type/psi _ Mortar Batching ___ Units: Block _ Electrode Storage __ Units: Brick . _ Torque Applied _._steel __ H.S. Bolts I __ Metal Decking ___ Electrodes __ Fireproofing ~ Other i;-p o~ ~ __ Corrective action required __ J.\.1ct1 ~:r: \20 _ Corrections completed }-\-1LT\ CERTIFICATION OF COMPLIANCE: To the best 9f our knowledge, ~II of the reported work, unless otherwise noted, substantially complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work inspected only and does not constitute engineering opin· ion or project control. DATE 7~ 1 ?-c::;.g PSI-B-900-170(2) Page_1_of_ INSPECTION REPORT CLIENT LEfi«P \ All'.\,,it;> Architect--J:::u...us------'----------~ Engineer V'¼IA-0 r::, .u Contractor Y';,1,,-H) NAO.:De. ::C,,:t..qn,;-I"'½-':? INSPECTION MAT'LSAMPLING otv _OSHPD __ Concrete Cylinders --·- _OSA __ Cement -- __ Specialty __ Mortar Samples -- __ Mechanical __ Grout Samples -- __ Electrical __ Masonry Prisms __ Roofing __ Masonry Block Lconcrete __ Fireproofing --__ Masonry __ Units (block or brick) -- __ Struct Steel __ Asphalt Concrete -- __ Prestress Cone __ Roofing -.--. __ Pile Driving __ Reinf. Steel -- __ Fireproofing __ Steel --__ waterproofing __ H.S. Bolts -- __ Non-Destructive __ Tendon (PT Strands) -- __ Soils Technician __ Other -- __ Batch Plant __ ·Other -- __ Bolt Pull-Out __ Other -- REMARKS ,.o /iJt 3@ ls'' o '-, !9'"'b-'. 7 c.::::::::::::: PROJECT (Name) L.moP \,,, A~ (Address) C+4:a...t c.. ?;,-+,.') o 14 REPORT NO. oss· :ZQLQ".L Building Permit No. _ei...,f?~· =-z...:,=-i:t::------------ Plan File No, _______________ _ Govt. Contract No.__,,----,------------ OSA or OSHPD #-------------- Other C-nsn ra:: }+ H ._ J::?v.N¼ ITT:;>1~ ,c..e: c.~,c;:,1..--.. MATERIAL DESCRIPTION INSPECTION CHECKLIST X Rinf.: Rebar 41 ., ,::;.. 11-., ..... d~ -x: Plan & Specs _ Rinf.: W.W.F. ' >< Clearances .. -.-Rinf.: Tendons X Positions __ Cone.: Mix #/psi -~Sizes __ Coric.: Mix #/psi ~Laps ___ Cone:: Mix #/psi _ Future Continuity #/psi . __ Grout: Mix #/psi . _ Consolidation __ Mortar: Type/psi _ Mortar Batching __ Units: Block Electrode Storage __ Units: Brick . -___ Torque Applied __ Steel -. _ H.S. Bolts __ Metal Decking __ Electrodes __ Fireproofing __ Other _ Corrective action required __ _ Corrections completed , J J ov,.:..'Y'-:d::< l d:Cc<?rZ'i'>tt½L:, -------· CERTIFICATION OF COMPLIANCE: To the best of our knowledge, all of the reported work, unless otherwise noted, substantially complies with approved plans, specifications and applicable sections of the building codes. This repo_rt covers the locations of the work inspected only and does not constitute engineering opin- ion or project control. INSPECTOR NAME :v...,:vt, c-"-C-t> < c:::s'.'>::l::O:'.bs.~ ,~ CERT. NO. e>S,sc.:>c, I?, \-.ta-5 (Print Clearly) -.. Q INSPECTOR SIGNATURE :12.J _ :;; ?~ DATE '7-\ "':"-'i~ PSI-B-900-170(2) Page_1_of_ -INSPECTION REPORT CLIENT t:51,,0 cA,vD DATE 7-/G-9S Architect ¼/<:::. -'----''-'------------------ Engineer /J?A/2-77,,v INSPECTION MAT'LSAMPLING QTY _OSHPD .>< Concrete Cylinders _!L_ _OSA __ Cement -- __ Specialty __ Mortar Samples -- __ Mechanical __ Grout Samples -- __ Electrical __ Masonry Prisms --__ Roofing __ Masonry Block -- .X-Concrete _._Fireproofing --__ Masonry __ Units (block or brick) -- __ Struct Steel __ Asphalt Concrete -- __ Prestress Cone . __ Roofing -- __ Pile Driving __ . Reinf. Steel __ Fireproofing __ Steel -- __ Waterproofing __ H.S. Bolts -- __ Non-Destructive __ TE;mdon (PT Strands) -·- __ Soils Technician __ Other -- __ Batch Plant ___ Other -- __ Bolt Pull-Out __ Other -- REMARKS A-Z: A-11,../'D Vt.,l f2...-I iVb C7 PROJECT (Name) &oz., o LA-AA";> (Address) CA-46 o&D C'/4 REPORT NO. OS 9-?o ZD ~ Building Permit No. -.L9"-'8'-'-__,2'--'o;:::;.....J7'--_______ _ Plan File No, _______________ _ GovL Contract No.--------------- OSA or OSHPD #-. ------------- Other Ma er H/(..(_ t::x/A..J6tfzy..l c~ (4<,--ll/r.1-- MATERIAL DESCRIPTiON. INSPECTION CHECKLIST · >< Rinf.: Rebar AblS)C!/.,/4::/'fv ''"" Plan & Specs __ Rinf.: W.W.F. x Clearances ---_ Rinf.: Tendons ~ Positions 2:C. Cone.: Mix #/psi (3.f'.,fu -~coo _Sizes __ Cone.: Mix #/psi _Laps _._. Cone.: Mix #/psi _ Future Continuity #/psi __ Grout: Mix #/psi :><" Consolidation __ Mortar: Type/psi _ Mortar Batching __ Units: Block _ Electrode Storage __ Units: Brick _ Torque.Applied __ Steel __ H.S. Bolts __ Metal Decking __ Electn;ides __ Fireproofing __ Other _ Corrective action required __ _ Corrections completed s·~;:,Ttf CERTIFICATION OF COMPLIANCE: To the best of our knowledge, all of the reportedwork, unless 6therwise·noted, substantially complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work inspected only and does not constitute engineering opin- ion or project control. CERT. NO. o&cJ 0'"1-S 1-S~ INSPECTOR SIGNATURE--.1-~::.......i.--=-~---'._.._ ____ _ DATE 7-/ fu -9$ PSl-8-900-170(2) l ria ti:!!-;/ Information ~..,. ®To Build On Engineering • Consulting • Testing REPORT OF CONCRETE COMPRESSiON TEST TESTED FOR: MR. DAVID CATTLE . LEGOLAND ESTATES INC 5600 AVENIDA ENCINAS SUITE 130 PROJECT: LEGOLAND THEME PARK CARLSBAD, CALIFORNIA CARLSBAD, CA 92008 DATE: June 22, 1998 REVISION #1 OUR REPORT NO.: 059-70202-696 FIELD DATA: LOCATION OF PLACEMENT CASTLE HILL ICE-CREAM PARLOR FOOTINGS @ BASE BUILDING PERMIT# 98-207 DATE PLACED June 12, 1998 SUPPLIER TIME DELIVERY TICKET NO.ffRUCK NO. SLUMP, IN. 4 MIX NUMBER AND PROPORTIONS AIR CONTENT, % CEMENT AIR TEMPERATURE, °F 81 WATE.R CONCRETE TEMPERATURE, °F 77 FINE AGGREGATE DATE RECEIVED IN LAB June 15, 1998 COARSE AGGREGATE FIELD DATA SUBMITTED BY PSI\DEREK P~TERSON ADMIXTURE MIX DATA SUBMITTED BY NELSON & SLOAN NOTE· APPLICABLE ASTM STANPARD™Ess.Qil:iERWJSE INDICATED· SLUMP· c143.goa· AIR CONTENT· C23M1b· TEMPERATURE· Cj064-86(9,3): CAPPlN!. · SPECIMEN TEST LABORATORY IDENTIFICATION AGE DATE OF COMPRESSION TEST RESU~ TS ASTM C39-94 TOTAL CYLINDER LOAD DIAMETER CYLINDER COMPRESSIVE AREA STRENGTH NELSON 522 _...;_ -~- & SLOAN NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (SQ.IN.) (PSI) TYPE OF BREAK 17232 A 7 06/19/98 83000 6.00 28.27 2940 Cone 17232 B 28 07/10/98 110000 6.00 28.27 3890 ·Cone 17232 C 28 07/10/98 105000 6.00 28.27 3710 Cone 17232 D - SPECIFICATIONS 28 3000 . REMARKS: X Cylinders made by PSI representative. Cylinders picked up by PSI X representative. · Test resulls comply with applicable X specifications. Cylinders made by Architect's or Contracto(s representative. Cyl[nders deJivered to PSl'laboratoiy. ALL CYLINDERS CAPPED IN ACCORDANCE WITH ASTM TECHNICIAN: DEREK PETERSON cc: LEGOLAND (4), BERNARD BROTHERS, H.O.K., CITY _OF CARLSBAD THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT. REPORTS MAY NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC. PSI A-200-4 (4)F Respectfully submitted, c;;z;,l~dustries, Inc. DAVID~~ DISTRICT MANAGER Professional Service Industries, Inc. • 6867 Nancy Ridge Drive, Suite E • San Diego, CA 92121 • Phone 619/455-0544 • Fax 619/455-1170 ·DSI Geotechn~c~JI l ·1 Environmental •-"Construction Consulting • Eng;neering • Testing REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: DATE: FIELD DATA: MR. DAVID CATTLE LEGOLAND ESTATES INC 5600 AVENIDA ENCINAS SUITE 130 CARLSBAD, CA 92008 July 28, 199!3 PROJECT: LEGOLAND THEME PARK CARLSBAD, CALIFORNIA OUR REPORT NO.: 059-70202-790 LOCATION OF PLACEMENT CASTLE HILL DUNGEON ICE CREAM SLAB-ON-GRADE PERMIT# 98-207 DATE PLACED TIME SLUMP, IN. , AIR CONTENT, % July 16, 1998 08:30 am 4 1/2 AIR TEMPERATURE, °F 84 CONCRETE TEMPERATURE, 0 F: 73 . DATE RECEIVED IN LAB t July 17., 1998 FIELD DATA SUBMITTED BY PSI\DEREK PETERSON MIX DATA SUBMITTED BY NELSON &· SLOAN SUPPLIER DELIVERY TICKET NO./TRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WAT!=R FINE AqGREGATE COARSE AGGREGATE ADMIXTURE NELSON & SLOAN 714537 1386 NOTE· APPUCABle..ASIM..llAND.AB.o.sJlNLESS OTHERWJSE JNPJCATEP·SLUMP· C1A3·90a· AIR CONTENI· C231·P1h· TEMPERATUBE· C10~1-86(93)' CAPPING· 91231·9_3 COMPRES~ION TEST. RESULTS SPECIMEN TEST LABORATORY IDENTIFICATION AGE DATE OF NUMBER OR SET NO. (DAYS) TEST 17432 A ·7 07/23/98 17432 B 28 08/;I.3/98 17432 C 28 08/13/98 17432 .D SPECIFICATIONS 28 REMARKS: X Cylinders made by PSI represen.tative. Cylinders made by Architect's or Contracto(s representative. ASTMC39-94 TOTAL CYLINDER LOAD DIAMETER (LBS.) (IN.) 53000 6.00 · Cylinders picked up by PSI . .K, representative. Cylinders delivered to PSI laboratory. CYLINDER . COMPRESSIVE AREA STRENGTH (SO.J.N.) (PSI). TYPE OF BREAK 28 .'27 1870 Cone 2500 Test results comply wilh applicable spe~ifications. • Test results do not comply with appliqable specifications. ALL CYLINDERS CAPPED IN ACCORDANCE WITH ASTM C617-94. TECHNICIAN: DEREK PETERSON cc: LEGOLAND (4), BERNARD BROTHERS,. ILO.K., CITY OF C~LSBAD THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT. REPORTS MAY NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC. PSI A-200-1 (4)F Respectfully submitted, ~~ Service Industries, Inc. DAVID J .• '~~ DISTRICT f:~E Information To Build On Professional Service Industries, Inc. • 6867 Nancy Ridge Drive, Suite E • San Diego, CA 92121 • Phone 619/455-0544 • Fax 619/455-1170