Loading...
HomeMy WebLinkAbout1 Legoland Dr; ; CBC2017-0235; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Print Date: 10/17/2017 Commercial Permit Permit No: CBC2017-0235 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 1 Legoland Dr BLDG-Commercial 2111000900 $0.00 www.carlsbadca.gov Work Class: P/M/E Lot#: Reference #: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Status: Applied: Issued: Fina led: Inspector: Closed -Finaled 05/09/2017 05/09/2017 05/09/2017 Description: LEGOLAND BURGER STOP KIOSK: REPLACEMENT OF (2) TON SPLIT SYSTEMS. REPLACING WITH 2 MINI-SPLIT SYSTEMS. CONDENSER LOCATED ON GROUND OUT OF SIGHT LINE, AHU LOCATED IN THE INTERSTITIAL SPACE ABVE T-BAR CEILING. PLUMBING, ELECTRICAL, AND MECHANICAL PERMIT Total Fees: $166.00 Owner: LEGOLAND CALIFORNIA LLC Po Box 543185 C/0 Property Tax Service Co DALLAS, TX 75354 Total Payments To Date: $166.00 Contractor: TRANE US INC 916-577-1100 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. $0.00 $166.00 ITHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: O PLANNING 0 ENGINEERING 0 BUILDING O FIRE O HEALTH O HAZMAT/APCD { Cicyof Building Permit Application Plan Check No. fJN 'J.-0/ ':J--(Cl_ 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Dep~sit . email: building@carlsbadca.gov www.carlsbadca.gov Date .~ / ;f/i~lswPPP JOB ADDRESS SUITEf/SPACU/UNln IAPN One Legoland Drive Carlsbad, CA 92008 --- CT/PROJECT# 'LOT# 'PHASE# I# OF UNITS I# BEDROOMS # BATHROOMS I TENANT BUSINESS NAME I CONSTR. TYPE I occ. GROUP Lego land DESCRIPTION DF WORK: Include Square Feet of Atrected Ana(s) Direct replacement of (2) Ton Split Systems at Burger Stop Kiosk. Condenser located on ground out of sight line, AHU located in interstitial space above t-bar ceiling. Replacing with (2) mini-split systems. EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE I AIR CONDITIONING I FIRE SPRINKLERS Comfort Cooling No Change YESO N<O YES 0No0 YESONoD APPLICANT NAME· Brian Bloker PROPERTY OWNER NAME Legoland ................ ADDRESS ADDRESS 3565 Corporate Court One Leaoland Drive CITY STATE ZIP CITY STATE ZIP San Dieao CA 92123 Carlsbad CA 92008 PHONE IFAX PHONE ]FAX 858-609-2561 858-609-2554 760-492-1645 none EMAIL EMAIL bbloker@trane.com Noel.Ferreras@legoland.com DESIGN PROFESSIONAL Trane US Inc, DBA Trane CONTRACTOR BUS. NAME Trane US Inc. OBA Trane ADDRESS ADDRESS 3565 Corporate Court 3600 Pammel Creek Rd CITY STATE ZIP CITY STATE ZIP San Dieao CA 92123 La Crosse WI 54601-7511 PHONE PHONE 858-609-2500 IFAX 858-609-2554 858-609-2500 IFAX 858-609-2554 EMAIL EMAIL thill@trane.com thill@trane.com I STATE UC. 561796 STATE UC.# I CC1 o. C38.I CITY BUS. uc.1234458 561796 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure. prior to its Issuance, also requires the applicant for such permit to file a signed statement that he Is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). Worl<ers' Compen11tlon Declaration: I hereby affirm under penalty of peljury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for wol1(ers' compensation as provided by Section 3700 of the Labor Code, for the performance of the wol1( for which this permit is issued. ~ have and will maintain w~pensatlon, as ulred by Section 3700 of the Labor ~~~ormance of the woli( for which this oermi~ issued. M~rs· compensa · ins nee carrier and policy number are: Insurance Co -I VA oF Policy No. Tc:2 ti u~ 1-'l _J)<f l-Expiration Date _ _,t....o..+--'-"..,_ ___ _ ~section need not be completed ff the permit Is for one hundred doll ($100) or less. LJ Certificate of Exemption: I certify that In the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Woll(ers' Compensation Laws of California WARNING: Failure to secure workers' compensation coverage is uni , and shall subject an employer to criminal penalties and clvll fines up to one hundr thousand dollars (&100,000), In addition to the cost of compensation, da~rovlded for in Secti Labor code, Interest and attorney's fees. _NS CONTRACTOR SIGNATURE ~ 0AGENT DATE I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the wol1( and the structure Is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement Is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contracto(s License Law does not apply to an owner of property who builds or Improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractors License Law). I am exempt under Section usiness and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. O ves 0 No 2. I (have I have not) signed an application for a building permit for the proposed woli(. 3. I have contracted with the following person (firm) lo provide the proposed construction (Include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major wol1( (include name I address I phone I contractors' license number): 5. I will provide some of the wol1(, but I have contracted (hired) the following persons to provide the woli( indicated (Include name I address I phone I type of wol1(): _NS PROPERTY OWNER SIGNATURE 0AGENT DATE - Is the applicant or future building occupant required to submit a business ptan, acutely hazaroous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes " No Is the applicant or Mure building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes " No Is the facility to be constructed 'Mthin 1,000 feet of the outer boundary of a school site? Yes " No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. Lender's Address I certify that I have read the application and state that the ab<Ml lnfonnation is correct and that the infonnation on the plans is accurate. I agree to comply~ all City ordinances and State lav.s relating to building construction. I hereby authorize represeotative of 1he City of Carlsbad t> enler upon 1he above menooned property b' inspection purJ'.X)SeS. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CllY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUEAGAJNST SAID CllY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required k>r excavations over 5'0' deep and demolition or construdoo of structures over 3 st>ries in heighl EXPIRATION: Every permit issued by 1he Building Offcial under the provisions of lhis Code shaU e · imitation and beCXJme nul and voo ~ the buildng or v.or1< authorized by such permit is not C00'1l1'leflred 'Mlhin 1B0days from the dale of such permit or Wthe build. lhorized by such permit is abanooned at any tine aflerthe v.or1< is commenced ape· of 1B0days (Se<fun 100.4.4 Unoorm Building Code). ,€5 APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. C r fl r I f I C A T E OF OCCUPANCY IC om m < r c, ,l I p t O j l' C t ', 0 n I y I Fax (760) 602-8560, Email buildinq@carlsbadca.gov or Mail the completed loon to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. I CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE I FAX EMAIL OCCUPANT'S BUS. UC. No. DELIVERY OPTIONS PICKUP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) ASSOCIATED CB# MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) NO CHANGE IN USE / NO CONSTRUCTION MAIL/ FAX TO OTHER: CHANGE OF USE/ NO CONSTRUCTION A$ APPLICANT'S SIGNATURE DATE ~:".ftlfr.~\~.il'.:'r~;:-,,t1·,-,.14~~'\.·tW.'.:.i<t.r.,~~~'llif'~~llif's'J.!.1~"1!fil!llf5'f~~~"~.,~~tl ~ PERMIT INSPECTION HISTORY REPORT (CBC2017-0235) Permit Type BLDG-Commercial Application Dato: 05/09/2017 Owner: Work Class: P/M/E Issue Dato: 05/09/2017 Subdivision· Status Closed -Finaled Expiration Date: 04/16/2018 Address: IVR Number: 3606 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 10/17/2017 10/17/2017 October 17, 2017 BLDG-43 Air Cond./Fumace Set 037732-2017 BLDG-Final Inspection Checklist Item BLDG-Building Deficiency 037733-2017 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Passed Paul Burnette COMMENTS Passed Paul Burnette COMMENTS LEGOLAND CALIFORNIA LLC CARLSBAD TCT#94-09 UNIT#02 & 03 1 Legoland Dr Carlsbad, CA 92008-4610 Reinspection Pas sod Yes Passed No No Yes No Yes Complete Complete Complete Page 1 of 1 • TRAIIE' Prepared For: Trane San Diego Sold To: Submittal Date: May 18, 2017 Customer P.O. Number: Customer Project Number: Job Number: Job Name: Lego/and Package Unit Conversion Project One Lego/and Drive CARLSBAD, CA 92008 Trane U.S. Inc. dba Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 2 Universal Match Ductless System Brian Bloker Trane 3565 Corporate Court San Diego, CA 92123-6396 Phone: (858) 576-2500 Cell: (916) 997-0539 Fax: (858) 576-2554 The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed between submittal generation and equipment release, the product performance and submittal data will need to be verified. It is the customer's responsibility to obtain such verification. J:\JOBS\ 116\77292\3\Legoland Package Unit Conversion Project MINI SPLIT SUBMITTAL.doc Table Of Contents Product Summary .......................................................................................................................... 1 Universal Match Ductless System (Item A1) ............................................................................... 3 Tag Data ................................................................................................................................................... 3 Product Data .............................................................................................................................................. 3 Mechanical Specifications ......................................................................................................................... 4 Unit Dimensions ......................................................................................................................................... 6 Accessory ................................................................................................................................................. 9 Field Installed Options -Part/Order Number Summary ........................................................... 11 Universal Match Ductless System .......................................................................................................... 11 Universal Match Ductless S stem Product Data -Universal Match Ductless System Item: Al Qty: 2 4TUK4530A 1 ONOA 30 MBh Heat Pump 4MUC4530A 1 ONOA 30 MBh Cassette Wireless Remote Control (Fld) EcoSmart (Fld) Ext. Control Interface Mod. (Fld) Cassette Panel 4Way (Fld) 50 Feet line set (Fld) Spare Filter (Fld) Condenser Pad (Fld) FLO = Furnished by Trane U.S. Inc. dba Trane I Installed by Others Equipment Submittal May 18, 2017 Page 3 of 11 Legoland Package Unit Conversion Project Mechanical Specifications -Universal Match Ductless System Item: A1 Qty: 2 OUTDOOR UNIT (Cassette Systems) General May 18, !2017 This unit is fully charged from the factory for up to 25 feet of piping. In cooling mode, the system is designed to operate at outdoor ambient temperatures between 23 and 115°F. With the addition of a wind baffle, cooling capacity is extended down to 0°F. Cooling and Heating capacities and efficiencies are AHRI certified. The unit is ETL listed for outdoor application. Unit Casing The unit casing is constructed of heavy gauge, galvanized steel and painted with weather-resistant powder paint. Refrigerant Controls Refrigeration system controls include condenser fan and compressor relays. Each outdoor unit is completely factory assembled, including a modulating linear expansion valve and suction line multi-function service valve. High and low pressure controls are inherent to the compressor. Compressor The compressor has inverter driven technology to modulate capacity. Additional features include internal thermal overload and pressure protection. A total dipping process protects hermetic motor windings. The compressor is mounted to avoid the transmission of vibration and noise. Condenser Coil The coil is manufactured with aluminum micro-channel tubing. The coil provides air flow resistance and efficient heat transfer. The coil is protected by the casing and coil guard. INDOOR UNIT (Cassette Systems) General Each air handler is a four-way cassette style indoor unit that recesses into the ceiling with a ceiling grille. Unit ships with a unit mounting template. Each cassette indoor unit is matched with a Trane outdoor unit, rated and tested in accordance with AHRI standard 210/240. Unit shall be ETL listed. Indoor Unit Each indoor unit is completely factory assembled including control circuit board and fan motor. Each indoor unit includes a condensate drain pan and built-in condensate drain pump. The indoor unit is factory and run tested. Unit Cabinet The indoor cabinet is a compact, space-saving ceiling-recessed cassette. Each corner portion of the panel cabinet is detachable, providing easy access to adjust the height. The cabinet panel has provisions for a field installed filtered outside air intake. Discharge Airflow and Distribution System Each cassette unit has auto swing, horizontal blades on all four sides to optimize the aperture outlet for airflow and air distribution. Blades close automatically when the system is turned off to minimize dust entering the unit. Each blade can be controlled individually. Fan The indoor fan is statically and dynamically balanced to run on a motor with permanently lubricated bearings. The indoor fan motor has available three speeds -High, Mid, and Low. Remote Controller Wired and wireless control is available for all units (sold separately). Available features include (depending on model): On/Off control Mode selection Temperature set-point Fan speed setting Dirty filter alert Scheduling FLO= Furnished by Trane U.S. Inc. dba Trane I Installed by Others Equipment Submittal Page 4 of 11 legoland Package Unit Conversion Project May 18, 2017 Condenser Pad (Ductless Systems) Solid wall construction made of chemical resistant polyolefin plastic. UV stable, resistant to sunlight and extreme hot or cold temperatures. Corner feet for greater stability and leveling. Accepts bolts and screws for unit anchoring. Lightweight constructions. FLO= Furnished by Trane U.S. Inc. dba Trane I Installed by Others Equipment Submittal Page 5 of 11 Legoland Package Unit Conversion Project Unit Dimensions -Universal Match Ductless System Item: A 1 Qty: 2 II 13" LJ r r ( '\l " 385/16" " n I I I 14 3116" ) l Uu 26 5/8" 20 13116" 21 1/8' NOTES: 1. Shipping Weight 163.1 lb 2. Net Weight 154.3 lb 3. Verijy weight, connection, and all dimension with Installer documents before installation 4TUK4524A10NOA • 4TUK4530A10NOA OUTDOOR UNIT FLO = Furnished by Trane U.S. Inc. dba Trane I Installed by Others Equipment Submittal May 18, ~017 I 151 /8" I 39 5/16" Page 6 of 11 t.egoland Package Unit Conversion Project Unit Dimensions -Universal Match Ductless System Item: A1 Qty: 2 r I - 37 318' -u ~. 2 3/16' 13 5/1611 5/16' L1 Min. 35 1/16" CEILING OPENING a,w~ I I 331/16" 149/16' 135/8' 71/4" I "" _ ... L--35 13/1128 15/16' ... .. I .) NOTES: 1 NET WEIGHT 41 7/8' 2. LIQUID PIPE CONNECTION 3/8' 3. GAS PIPE CONNECTION 5/8' 4. OD 1', ID 13/16' 5. VERIFY WEIGHT. CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 2 3/16' 3 3/4' 43/4' L 331/16' 1 3/4' "1'q 10 5/8' 1113/16' 4MUC4530A10NOA THROUGH 4MUC4548A10NOA CASSETTE· IN DOOR UNIT FLO= Furnished by Trane U.S. Inc. dba Trane I Installed by Others Equipment Submittal May 18, 2017 Min. 35 1/16' CEILING OPENING SUSPENSION POSITION 2 3/16' 3 3/8" 6 7/16' 81/2' Page 7 of 11 Legoland Package Unit Conversion Project Unit Dimensions -Universal Match Ductless System Item: A1 Qty: 2 Specifications SYSTEM MODEL NUMBER Power Supply Rated Coofing/Heating Capacity (Btulh) Cooling Capacity (Mix) 095'F (Btulh) Cooling Capacfy (Min) 095'F (Btu/h) Heating Capacfy (Max) 047°F (Btu/h) Heating Capacity (Min) 047°F (Btu/h) Heating Capacity (Max) 017'F (Btulh) Heating Capacfy (Rated) O 17'F (Btulh) Heating Capacfy 05'F (Btulh) Heating Capacity 0-4°F (Btulh) SEER/HSPF EER O 95'F Dehumidfywlg Volume (pt/hr) Rated Power Input (W) Nominal Input Current (A) INDOOR UNIT Motor Type Output FLA(A) Fan Type Motor RPM H/M/L (RPM) Air Flow Rate H/M/L (UL) (elm) Construction Sound Power Level dB(A) Sound Pressure Level dB(A) Filter Condensate Max. Lifting Height (in) Drain Pump Displacement(pt./hr.) Wired Remote Control Wireless Remote Control Type Liquid Pipe (in.) Gas Pipe (In.) Condensate Drain (In.) Net Weight (lbs.) Shipping Weight (lbs.) Net Dimensions (WxHxD) (in.) Shipping Dimensions (WxHxD) (in.) Model Number Net Weight (lbs.) Shipping Weight (lbs.) Net Dimensions (WxHxD) (in.) Shipping Dimensions (WxHxD) (In.) OUTDOOR UNIT Type LAA ALA Motor Type Output X n (W) FLA(A) Fan Type Air Flow Rate (elm) MCA MOP Construction Sound Power Level dB(A) Sound Pressure Level dB(A) Type Liquid Pipe (in.) Gas Pipe (in.) Net Weight (lbs.) Shipping Weight (lbs.) Net Dimensions (WxHxD) (n) Shipping Dimensions (WxHxD) (in.) Type Control Method Holding Charge (lbs.) Addltional Charge (oz..lft.) APPLICATION LIMITS CoolingWithout Wind Baffle CoolingWlth Wind Baffle Heating Maximum length (ft.) Maximum length with No Add'I Ref. (ft.) Maximum Height Difference (ft.) 4MUC4524A 1 ONOA/4TUK4524A 1 ONOA Cooling Heating 30,000 35,000 9,300 NIA NIA N/A NIA NIA NIA 19.20 10.40 7.03 2.89 13.4 208-230/60/1 4MUC4524A10NOA BLOC 0.125 HP 0.35 Turbo 480,/420/360 840/720/600 Fin/Copper Tube 3 53 Washable Mesh 47.25 (12D0mm) 50. 7 (24 llters) TVCTRLTWRWE10T TVCTRLTRDHOOUT Flare 318' 5/8' 32,000 NIA NIA 38,000 9,000 32,500 21,300 26,500 19,000 9.80 10.30 7.03 3.11 14.4 VP 25 (OD 32mm, ID 25mm) 41.9 52.9 33 X 33 X 11.35 35.4 X 14.1 X 35.4 TVEPANPC4NUSET 13 19 37 1/2 X 37 318 X 1 3116 39.6 X 3.94 X 39.6 4TUK4530A 1 ONOA Rotary Inverter NIA NIA BLOC 125 X 1 0.48 Propeller 2220 23.2 30 Aluminum Micro Channel 50 65 Flare 318. 5/8' 154.3 163.1 37.0 X 13.0 X 39.3 35.4 X 14.1 X 35.4 R-410A EEV 5.73 0.24 4MUC4524A 1 ONOA/4TUK4524A 10NOA 23· 115' F 0 -115° F -4 • 75' F 164 25 98 May 18, :!017 R-41 OA Mini Split System (C-SERIES) NOTE: 1. Capacity based on 25 ft. of equivalent refrigerant piping with Oft. level difference. • Cooling: Indoor temperature 80' F DB, 67' F W. Outdoor temperature 95' F DB, 75' F WB • Heating: Indoor temperature 70' F DB, 60' F W, Outdoor temperature 47' F DB, 43' F WB 2. Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation requirements 3. Cassette panels and remote controls must be ordered separately 4. Unit includes an accessory drain hose connector 5. Indoor unit receives power from the outdoor unit through field-supplied Interconnecting wiring FLO = Furnished by Trane U.S. Inc. dba Trane I Installed by Others Equipment Submittal Page 8 of 11 'Legoland Package Unit Conversion Project Accessory -Universal Match Ductless System Item: A1 Qty: 2 Wireless Controller: TVCTRL TRDHOOUT • Infrared control of indoor units • Utilizes temperature sensor included at indoor unit for room temperature sensing Control Features • Temperature setpoint • Operation mode o Auto-Cool-Dry-Fan-Heat • Fan speed o Auto-Low-Med-High • Filter alarm reset (timer) ~ Cool Dry Fan Heat 0 =.<i> ~ 9 «~¢ Ell ,~EJim o:~ mm ruJl~I.I_I HR '*•Ill Room Blade OJ (ID@]@] • Adjustment of individual airflow blade control (cassette units) • 4 transmission channel options can separate control to specific indoor units, and help eliminate unintentional control of units in adjacent spaces Effective range 20 feet (7m) Power requirements 3 VDC provides by 2 AAA batteries (included) Dimensions W x H x D = 2 x 5.5 x 1 = 49 x 138 x 29 (mm) FLO= Furnished by Trane U.S. Inc. dba Trane I Installed by Others Equipment Submittal May 18, 2017 Page 9 of 11 Legoland Package Unit Conversion Project Accessory -Universal Match Ductless System Item: A1 Qty: 2 63/4" 61/8" 5 5/8" <i. / I ' @ @ I /-+ -, G' __,~ ~ ._ ----f-B--~ ~ I \. @ I @ ---------55/8" --------- 635" 105" J 2112" 1 1/8" l May 18, :!017 0 @ 0 Part Number: Power. Required Hardware: Compatibiity: ENVIRONMENT Min: Max: Min: Max: 1/0 CONNECTIONS -h. 4 7/8" TVCTRLTECOVRF1 B 24V AV & 12·24V DC For use with EcoAir, Eco Touch or other compatible Z,gbee remote Interfaces Trane VRF HVAC untts via Power Line Communication 32.0F 122.0 F 10 % Relative Humidity (non-condening) 90 % Relative Humidity (non-condening) NTC Temperature Probe: 1 Input Day Contact Input 6 Input Analog Vale Control Output: 3 Output, 0-10V, 4-20mA (optional) Power Output: 12V & 3.3V EXTERNAL NTC TEMPERATURE PROBE Min: 35.0 F Max: 120.0 F • standard range; other range option are acailable INTERNAL MESH NETWORK RADIO Specttication: ZigBee IEEE 802.15.4 Radio Band: 2.4 GHz ISM Band Radio Power: 16dBM = 4QmW Radio Range: Up to 3600" based on environment 0 TVCTRL TECOVRF 1 B • ECOSMART VRF CONTROLLER FILTER BOX FLO= Furnished by Trane U.S. Inc. dba Trane I Installed by Others Equipment Submittal Page 10 of 11 • Legoland Package Unit Conversion Project May 18, 2017 Field Installed Options -Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family -Universal Match Ductless System A1 No Ta 2 Universal Match Ductless S stem Field Installed Option Description 50 Feet line set Ext. Control Interface Mod. Spare Filter Wireless Remote Control EcoSmart Cassette Panel 4Wav Condenser Pad FLO= Furnished by Trane U.S. Inc. dba Trane I Installed by Others Equipment Submittal Model Number Part/Ordering Number TAYREFLN965 TVCTRLTIMB14AO FL TR4TVC4MUC01 TVCTRL TRDHOOUT TVCTRL TECOVRF1 B TVEPANPC4NUSET PAD01112 Page 11 of 11