Loading...
HomeMy WebLinkAbout1 Legoland Dr; ; CBC2017-0665; Permit(city of Carlsbad Commercial Permit Print Date: 04/27/2018 Permit No: CBC2017-0665 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 1 Legoland Dr BLDG-Commercial 2111000900 $77,340.78 Work Class: Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Addition Status: Applied: Issued: Permit Finaled: Inspector: Closed -Finaled 12/27/2017 02/09/2018 PBurn Plan Check#: Final Inspection: 4/27/2018 10:53:36AM Project Title: Description: LEGOLAND GARDEN RESTAURANT: 253 SF ADDITION & 660 SF T.I. Applicant: BAKER ARCHITECTURE TONY KERLESHI Owner: LEGOLAND CALIFORNIA LLC 4080 Centre St, 203 San Diego, CA 92103-2655 619-281-5937 Po Box 543185 C/0 Property Tax Service Co DALLAS, TX 75354 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL FIRE A-2 & A-3 Occupancies -Tl PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $1,666.73 Total Payments To Date: $1,666.73 Contractor: COMMERCIAL BUILDEERS INC 525 B St, 1010 San Diego, CA 92101-4401 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. $0.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 I I www.carlsbadca.gov $530.04 $371.03 $60.00 $609.00 $71.00 $4.00 $21.66 \ «~t ~ CITY OF CARLSBAD JOBADDRES CT/PROJECT# EMAIL ADDRESS CITY PHONE EMAIL ARCH/DESIGNER NAME & ADDRESS Building Permit Application 1635 Faraday Ave .• Garlsbad. CA 92008 760-602-2717 / 2718/ 2719 Fax: 760-602-8558 www.carlsbadca.gov APPLICANT NAME ADDRESS CITY PHONE EMAIL CONTRACTOR BUS. NAME STATE ZIP FAX STATE UC.# I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason: Plan Check No. Est. Value Plan Ck. Deposit Date STATE ZIP FAX o I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business aod Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). l:J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not appJy to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). l:J I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide lhe major labor and materials for construction of the proposed property improvement. 0 Yes O No 2. I (have I have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work)· ~ PROPERTY OWNER SIGNATURE Cl AGENT DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? O Yes 'Xl.No Is the applicant or future building occupant required to obtain a permit froln the air polluUon control district or air quality management district? 0 Yes ~ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? O Yes XI No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED ~NLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the application and state that the above Information Is conectancl that the Information on the plans is accurate. I agree to comply with all City on:Hnances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad toenteru~ the atove men00!1ed property br ins~n purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HAAMLESS THE CITY OF CARLSBAD Ac;.\INST ALL UNlllrTIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST &\ID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: MOSHA permit is required for excavations over 5'0' deep and dem:illtion or oonstruction of structures over 3 stories in height. EXPIR-<\TION: Every permit issued by the Buik:ling · · ions of this Code shall expire by limitation and become null and -.old if the buik:ling orw:irk authorized by such permit is not commenced 'Mlhin 180 days from the date of such permit or if the by such permit is susl);30ded or abandoned at any lime after the y,(J(!( is o:immenced for a perioo of 100days (Section 106.4.4 Uniform Buildrlg Code). _I$ APPLICANT'S SIGNATURE DATE Pcrinit Type: BLDG-Commercial Application Date: 12/27/2017 Owner: LEGOLAND CALIFORNIA LLC Work Class: Addition Issue Date: 02/09/2018 Subdivision: CARLSBAD TCT#94-09 UNIT#02 & 03 Status: Closed -Finaled E.xpiration Date: 09/2412018 Address: 1 Legoland Dr Carlsbad, CA 92008-4610 tVR Number· 8567 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete 03!02/2018 03/02/2018 BLDG-21 050470-2018 Passed Andy Krogh Complete Underground/Underf loor Plumbing 03/09/2018 03/09/2018 BLOG-12 Steel/Bond 051091-2018 Passed Paul Burnette Complete Beam Checklist ltcn1 COMMENTS Passed BLDG-Building Deficiency Yes 03/12/2018 03/12/2018 BLOG-11 051400-2018 Passed Andy Krogh Complete Foundatlon/Ftg/Pier s (Rebar) BLDG-31 051401-2018 Passed Andy Krogh Complete Underground/Condu It-Wiring 03/22/2018 03/22/2018 BLDG-84 Rough 052526-2018 Failed Andy Krogh Reinspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Called and no answer. voicemail says No mailbox is full and no new messages accepted BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 03/23/2018 03/23/2018 BLDG-16 Insulation 052604-2018 Fa lied Michael Collins Reinspection Complete Chocklist Item COMMENTS Pas sod BLDG-Building Deficiency Not ready No BLDG-84 Rough 052737-2018 Passed Michael Collins Complete Combo{14,24,34,44) April 27, 2018 Page 1 of2 Permit Type: Work Class: Status: Scheduled Date 03(26/2018 03/28/2018 04/25/2018 04/27/2018 BLDG-Commercial Application Date: 12/27/2017 Owner: Addition Issue Date: 02/09/2018 Subdivision: Closed -Finaled Expiration Date: 09/24/2018 Address: Actual Start Date 03(26/2018 03/28/2018 04(25/2018 04/27/2018 IVR Number: 8567 Inspection Type Inspection No. Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLOG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers BLDG-17 Interior 052763-2018 Lath/Drywall BLDG-17 lnterlor 053043-2018 Lath/Drywall BLDG-18 Exterior 053148-2018 Lath/Drywall BLDG-Final 056051-2018 Inspection Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final BLDG-Final 056328-2018 Inspection Checklist ltctn BLDG-Plumbing Final BLDG-Structural Final BLDG-Electrical Final Inspection Status Primary Inspector COMMENTS Walls only Called and no answer, voicemail says mailbox is full and no new messages accepted Passed Andy Krogh Passed Andy Krogh Passed Andy Krogh Failed Paul Burnette COMMENTS Passed Andy Krogh COMMENTS -------- April 27, 2018 LEGOLAND CALIFORNIA LLC CARLSBAD TCT#94-09 UNIT#02 & 03 1 Legoland Dr Carlsbad, CA 92008-4610 Re inspection Complete Passed Yes Yes Yes Yes No No No No No Complete Complete Complete Reinspection Complete Passed No No No No No Complete Passed Yes Yes Yes Page 2 of 2 DATE: January 24, 2018 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2017-0665 PROJECT ADDRESS: 1 Legoland Dr. .;. EsG1I f:1 SAFE:built Cornp,:,11y SET: II Q APPLICANT _..i;;i--:1URIS. PROJECT NAME: Kiosk Addition/Remodel Garden Restaurant C8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: C8J EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted;.:,· ,...~--(1 _Telephone#: Date contacted: \ucy ·v Email: Mail Telephone Fax In Person D REMARKS: By: Kurt Culver EsGil 1/23/18 Enclosures: 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ' DATE: January 5, 2018 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2017-0665 PROJECT ADDRESS: 1 Legoland Dr. /. EsG1I A SAFEb1Jilt Comp0n<J SET: I g,_t,J'PLICANT /° JURIS. PROJECT NAME: Kiosk Addition/Remodel Garden Restaurant D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Tony Kerleshi D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Tony Kerleshi k,ate citacted: \ f s (b~Email: ,tJMail leph~ Fax In Person D ~-REMAR : Telephone#: 619-358-9225 tony@BakerArchitecture.com By: Kurt Culver EsGil 12/29/17 Enclosures: 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad CBC2017-0665 ' January 5, 2018 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK#.: CBC2017-0665 OCCUPANCY: A2 TYPE OF CONSTRUCTION: V-B ALLOWABLE FLOOR AREA: OK SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 12/27/17 DATE INITIAL PLAN REVIEW COMPLETED: January 5, 2018 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: Restaurant ACTUAL AREA: +253 STORIES: 1 HEIGHT: n/c OCCUPANT LOAD: n/ c DATE PLANS RECEIVED BY ESGIL CORPORATION: 12/29/17 PLAN REVIEWER: Kurt Culver This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarificatipn, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC2017-0665 January 5, 2018 • GENERAL 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. • PLANS 2. Revise the plans to show the required 5' clearance in the direction of swing for Door 003. Title 24. 3. Specify minimum 1/4 inch per foot roof/deck slope for drainage. Section 1507.10.1. 4. Has the existing trellis/truss been checked for increased loads? Since the existing trellis was open to the sky, the original design for it would have had zero live load; the proposed solid roof must be designed for a live load of 20 psf. • ADDITIONAL 5. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 6. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: D Yes D No 7. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kurt Culver at Esgil. Thank you. CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbr1dca.gov DATE: 1/5/18 PROJECT NAME: LEGO GARDEN RESTAURANT PROJECT ID: N/A APN: PLAN CHECK NO: CBC2017-0665 SET#: 1 ADDRESS: 1 LEGOLAND DRIVE ~ This plan check review is complete and has been APPROVED by the PLANNING Division. By: TERI DELCAMP A Final Inspection by the PLANNING Division is required D Yes [:;<;] No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. 0 This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: For questions or clarifications on the attached checklist please contact the following reviewer as marked: ~ D D PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Teri Delcamp D Chris Glassen D Cindy Wong 760-602-4611 760-602-2784 760-602-4662 teri.delcamg,@carlsbadca.gov Christog_her.Glassen@carlsbadca.gov Cynthia.Wong_@carlsbadca.gQY Gina Ruiz D Val Ray Marshall [J Dominic Fieri 760-602-4675 760-602-27 41 760-602-4664 Gina.Ruiz@carlsbadca.gov Val Ray. Ma rshall@ca rlsbad ca.gov Dom i 11 i c.Fieri_~;ga rls!?ad ca .go\: D Linda Ontiveros D 760-602-2773 Li1Jda.Q_nJive_ros@carlsbadca,gQY. Remarks: Beverage kiosk enclosure under portion of existing covered area at Garden Restaurant within Inner Park at Legoland. Meets all requirements; exempt from SDP/CDP. ' DODD C 7490 OPPORTUNIY RD., STE 350~ SAN DIEGO, CA 92111 - & ASSOCIATES (619) 260-0057 U <.: CONSULTING ENGINEERS .. ii!! b ' ~ Oz <o tXl -Cl) Cl) ....J> 0:: -<( 0 u (!) u. z Oo ~ u STRUCTURAL CALCULATIONS FOR GARDEN REST AU RANT -LEGOLAND CLIENT= DA TE ISSUED= OWNER 01-15-2018 CBC2017 -0665 1 LEGOLAND DR LEGCLAND GARDEN RESTAURANT: 253 SF ADDITION & 660 SF T.I 2111000900 1/18/2018 CBC2017-0665 Jti Z X -.25k/ft Loads: BLC 2, LIVE LOAD DODD AND ASSOCIATES LEGOLAND TRUSS TYP. TRUSS F SK -1 1 Jan 15, 2018 at 11 :42 AM unlitled.r3d Company Designer Job Number Global DODD AND ASSOCIATES Disolav Sections for Member Cales Max Internal Sections for Member Cales Include Shear Deformation Include Waroino Area Load Mesh (in'2l Merae Tolerance (inl P-Delta Analvsis Tolerance Vertical Axis Global Member Orientation Plane Hot Rolled Steel Code Cold Formed Steel Code Wood Code Wood Temperature Concrete Code Mason"' Code Aluminum Code Number of Shear Reaions Reaion Soacina Increment (in) Biaxial Column Method Parme Beta Factor /PCAl Concrete Stress Block Use Cracked Sections Bad Framina Warninas Unused Force Warninas Seismic Code Seismic Base Elevation (ft) CtX CtZ TX /sec) T Z /secl RX RZ Ct Exo. X Ct Exe. Z Ca Cv Nv SD1 SDS S1 TL /secl Occuoancv Code Seismic Zone Occuoancv Cat Use Gravitv Self Wt in Diaohraam Mass Use Deck Self Wt in Diaphraam Mass Use Lateral Self Wt in Diaohraam Mass Seismic Detailina Code OmX ,m Z RhoX ~ha Z LEGOLAND TRUSS 5 97 Yes Yes 144 .12 0.50% y xz AISC 13th/360-05l: ASD /Direct Analvsis AISI NAS-07: ASD AF&PA NDS-05/08: ASD < 100F ACI 318-08 ACI 530-05/08: ASD AA ADM1-05: ASD 4 4 Exact lntearation .65 Rectanoular Yes No Yes ASCE 7-05 Not Entered .02 .02 Not Entered Not Entered 3 3 .75 .75 .36 .54 1 1 1 1 5 4 3 I or II Yes Yes Yes None 1 1 1 1 RISA-3D Version 9.1.0 [C:IRISA\untitled.r3d] .. ethod) Jan 15, 2018 11:45 AM Checked By: Page 1 ' Company Designer Job Number DODD AND ASSOCIATES Basic Load Cases BLC Oescri tion 1 DEAD LOAD 2 LIVE LOAD Load Combinations LEGOLAND TRUSS Cate o X Gravit DL -1 LL Joint Point Jan 15, 2018 11:45 AM Checked By: Descrintinn So .. ?Delta SR .. BLC Fae ... BLr. Fac ... BLCFae. .BLC Fae ... BLC Fae ... BLC Fae .. .BLr. F00 .. .BLC Fae ... 1 D Yes y 1 1 2 D+L Yes y 1 1 2 1 3 D+0.75L Yes y 1 1 2 .75 Member Distributed Loads {BLC 1 : DEAD LOAD) Member Label Direction Start Mannitudefk/ft d. . End Maanitudefk/11 den Start Locationfft 0/ol End Locationrft o/ol 1 M2 y -.225 -.225 0 0 2 M7 y -.225 -.225 0 0 3 M12 y -.225 -.225 0 0 Member Distributed Loads {BLC 2 : LIVE LOAD) Member Label Direction Start Mannjtt1di:>rk/ft d .. End Mannituderktft den Start Locationrft o/ol End Locationrft 01o1 1 M2 y -.25 -.25 0 0 2 M7 y -.25 -.25 0 0 3 M12 y -.25 -.25 0 0 Member Area Loads Joint A Joint B Joint C Joint D Direction Distribution No Data to Print . Joint Coordinates and Temperatures Label X rn1 y lftl z lfll Temn fFl Detach From Oiar"l ... 1 N1 -0.278669 0.948849 0 0 2 N2 -0.278669 2.948849 0 0 3 N3 3.051331 0.948849 0 0 4 N4 3.051331 2.948849 0 0 5 NS 6.381331 0.948849 0 0 6 N6 6.381331 2.948849 0 0 7 N7 9.711331 2.948849 0 0 8 NB 9.711331 0.948849 0 0 Joint Boundary Conditions Joint Label X fk/inl Y fk/inl Z fk/inl X Rot.rk-fVradl Y Rnt_lk-ft/r0 "' Z Rnt_lk-ftlr0 "' Footinn 1 N1 Reaction Reaction Reaction 2 NB Reaction Reaction Reaction 3 N2 Reaction Reaction Reaction 4 N7 Reaction Reaction Reaction 5 N3 Reaction Reaction Reaction 6 N6 Reaction Reaction Reaction 7 NS Reaction Reaction Reaction 8 N4 Reaction Reaction Reaction RISA-3D Version 9.1.0 [C:IRISA\untitled.r3d] Page 2 DODD AND ASSOCIATES Company Designer Job Number LEGOLAND TRUSS Jan 15, 2018 11:45 AM Checked By: Member Primary Data Label I Joint J Joint K .loint Rotatel. .. Section/Shane T""e D"' ... i"n Uc:.t Material Oesinn .. 1 M1 N1 N2 VERT MEMBER Beam Tube A36 Gr.36 T""ical 2 M2 N2 N4 TOP CHORD Beam Tube A36 Gr.36 T""ical 3 M3 N4 N3 VERT MEMBER Beam Tube A36 Gr.36 T""ical 4 M4 N3 N1 BOTTOM CHORD Beam Tube A36 Gr.36 T"nical 5 M5 N4 N1 DIAGONAL TUBE Beam Tube A36 Gr.36 T""ical 6 M6 N2 N3 DIAGONAL TUBE Beam Tube A36 Gr.36 T""ical 7 M7 N4 N6 TOP CHORD Beam Tube A36 Gr.36 T""ical 8 MB N5 N3 BOTTOM CHORD Beam Tube A36 Gr.36 T""ical 9 M9 N6 N3 DIAGONAL TUBE Beam Tube A36 Gr.36 T"nical 10 M10 N4 N5 DIAGONAL TUBE Beam Tube A36 Gr.36 T""ical 11 M11 N6 N5 VERT MEMBER Beam Tube A36 Gr.36 T""ical 12 M12 N6 N7 TOP CHORD Beam Tube A36 Gr.36 T""ical 13 M13 NB N5 BOTTOM CHORD Beam Tube A36 Gr.36 T""ical 14 M14 N7 N5 DIAGONAL TUBE Beam Tube A36 Gr.36 T"nical 15 M15 N6 NB DIAGONAL TUBE Beam Tube A36 Gr.36 T""ical 16 M16 N7 NB VERT MEMBER Beam Tube A36 Gr.36 T""ical Hot Rolled Steel Section Sets Label Shane T"-e Oesinn List Material Desinn .. A fin21 I"" fin41 lzz fin41 J fin41 1 DIAGONAL TUBE HSS2X2X4 Beam Tube A36Gr.36 T"nical 1.505 .744 .744 1.31 2 TOP CHORD HSS3X3X4 Beam Tube A36 Gr.36 T""ical 2.435 3.014 3.014 5.069 3 BOTTOM CHORD HSS3X3X4 Beam Tube A36 Gr.36 Tvnical 2.435 3 014 3.014 5.069 4 VERT MEMBER HSS3X3X4 Beam Tube A36 Gr.36 T""ical 2.435 3.014 3.014 5.069 Envelope A/SC 13th(360-05/: ASD Steel Code Checks Memb. . Shane Code Check Lo ... LC Sh ... Locrn Dir LC Pnc/o ... PnVo ... Mn·--/. .. Mnzz/o ... Cb Enn 1 M1 HSS3X ... .055 2 2 .012 0 V 2 51.221 52.491 4.446 4.446 1.939 H1-1b 2 M2 HSS3X ... .109 .33 2 .061 3.33 V 2 49.045 52.491 4.446 4.446 2.038 H1-1b 3 M3 HSS3X ... .001 1 1 .001 2 V 1 51.221 52.491 4.446 4.446 1.136 H1-1b 4 M4 HSS3X ... .011 .33 2 .002 0 V 2 49.045 52.491 4.446 4.446 2.18 H1-1b 5 M5 HSS2X ... .010 0 2 .002 0 V 2 25.741 32.443 1.73 1.73 2.288 H1-1 b 6 M6 HSS2X ... .020 0 2 .003 3.884 V 2 25.741 32.443 1.73 1.73 1.997 H1-1b 7 M7 HSS3X ... .104 .33 2 .057 3.33 " 2 49.045 52.491 4.446 4.446 2.69 H1-1b 8 MB HSS3X ... .001 .33 2 .000 0 V 1 49.045 52.491 4.446 4.446 2.214 H1-1b 9 M9 HSS2X ... .004 3 ... 2 .001 3.884 V 2 25.741 32.443 1.73 1.73 1.675 H1-1b 10 M10 HSS2X ... .007 0 2 .001 0 V 2 25.741 32.443 1.73 1.73 2.918 H1-1b 11 M11 HSS3X ... .001 1 1 .001 2 V 1 51.221 52.491 4.446 4.446 1.136 H1-1b 12 M12 HSS3X ... .108 0 2 .061 0 V 2 49.045 52.491 4.446 4.446 2.023 H1-1b 13 M13 HSS3X ... .009 0 2 .001 0 V 2 49.045 52.491 4.446 4.446 2.168 H1-1b 14 M14 HSS2X ... .024 0 2 .002 0 V 2 25.741 32.443 1.73 1.73 2.348 H1-1b 15 M15 HSS2X ... .010 3 .... 2 .002 3.884 V 2 25.741 32.443 1.73 1.73 2.337 H1-1b 16 M16 HSS3X ... .055 0 2 .012 0 " 2 51,221 52.491 4.446 4.446 2.02 H1-1b Hot Rolled Steel Properties Label E fksi G fksil Nu Therm 111E .. Oensitvrklft ... Yieldfksil Rv Fufksil RI 1 A36 Gr.36 29000 11154 .3 .65 .49 36 1.5 58 1.2 2 A572 Gr.50 29000 11154 .3 .65 .49 50 1.1 65 1.1 3 A992 29000 11154 .3 .65 .49 50 1.1 65 1.1 4 A500 Gr.42 29000 11154 .3 .65 .49 42 1.4 58 1,3 5 A500 Gr.46 29000 11154 .3 .65 .49 46 1.4 58 1.3 RISA-3D Version 9.1.0 [C:IRISA\untitled.r3d] Page 3 Company Designer Job Number DODD AND ASSOCIATES Envelope Joint Reactions Joint Xlkl LC 1 N1 max .18 2 2 min .102 1 3 N8 max -.038 1 4 min -.116 2 5 N2 max -.044 1 6 min -.128 2 7 N7 max .192 2 8 min .108 1 9 N3 max .065 2 10 min .06 1 11 N6 max .053 1 12 min .05 2 13 NS max .051 1 14 min .047 2 15 N4 max .061 2 16 min .058 1 17 Totals: max .351 3 18 min .351 1 Envelope Joint Displacements Joint X linl LC yrjnl 1 N1 max 0 1 0 2 min 0 2 0 3 N2 max 0 2 0 4 min 0 1 0 5 N3 max 0 1 0 6 min 0 2 0 7 N4 max 0 1 0 8 min 0 2 0 9 NS max 0 2 0 10 min 0 1 0 11 N6 max 0 2 0 12 min 0 1 0 13 N7 max 0 1 0 14 min 0 2 0 15 N8 max 0 2 0 16 min 0 1 0 LEGOLAND TRUSS y [kl LC z 'k' LC MX 1k-ft1 LC MY 'k-ft' .028 2 0 1 0 1 0 .014 1 0 1 0 1 0 .024 2 0 1 0 1 0 .01 1 0 1 0 1 0 .717 2 0 1 0 1 0 .338 1 0 1 0 1 0 .721 2 0 1 0 1 0 .343 1 0 1 0 1 0 -.005 1 0 1 0 1 0 -.011 2 0 1 0 1 0 1.638 2 0 1 0 1 0 .776 1 0 1 0 1 0 -.005 1 0 1 0 1 0 -.01 2 0 1 0 1 0 1.638 2 0 1 0 1 0 .776 1 0 1 0 1 0 4.745 2 0 1 2.248 1 0 1 LC Z linl LC X Rotation rrad1 LC Y Rotation r radl LC 1 0 1 0 1 0 1 2 0 1 0 1 0 1 -- 1 0 1 0 1 0 1 2 0 1 0 1 0 1 2 0 1 0 1 0 1 1 0 1 0 1 0 1 1 0 1 0 1 0 1 2 0 1 0 1 0 1 2 0 1 0 1 0 1 1 0 1 0 1 0 1 1 0 1 0 1 0 1 2 0 1 0 1 0 1 1 0 1 0 1 0 1 2 0 1 0 1 0 1 1 0 1 0 1 0 1 2 0 1 0 1 0 1 RISA-3D Version 9.1.0 [C:IRISA\untitled.r3d] Jan 15, 2018 11:45AM Checked By: L" MZ 'k-fl' 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 Z Rotation rradl 8.192e-5 4.118e-5 -1.51e-4 -3.138e-4 5.305e-6 4.384e-6 6.936e-5 3.098e-5 2.728e-6 1.808e-6 -3.81 e-5 -7.647e-5 3.048e-4 1.42e-4 -3.213e-5 -7.287e-5 LC 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LC 2 1 1 2 2 1 2 1 1 2 1 2 2 1 1 2 Page4 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE Business Contact OFFICE USE ONLY RECORD ID#~~~~~~~~~~~~~~~~~~ PLANCHECK#~~~~~~~~~~~~~~~~I BP DATE Telephone# Zip Code CfZioO.B Zip Code Plan File# he following questions re sent he f ility's activities, NOT the specific project de cript on. PART I: FIRE DEPARTMENT-HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 13. Corrosives 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART 11: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. Expected Date of Occupancy: FEES ARE REQUIRED Project Completion Date: (for new construction or remodeling projects) Is your business listed on the reverse side of this form? (check all that apply). 0 CalARP Exempt I 1. 2. 3. 4. 5. 6. 7. 8. YES NO § l D D D D D I Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? Will your business store or handle carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or reater than 1,320 allons? California's Above round Petroleum Stora e Act . Date Initials D CalARP Required I Date Initials 0 CalARP Complete I Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCD): Any YES• answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcomp@sdcountv.ca.gov (858) 586-2650). [·No stamp required ifQ1 Yes and Q3 Yes and Q4-Q6 No]. The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except -those with more than one building .. on the property: single buildings with more than four dwelling units: townhomes; condos; mixed-commercial use; deliberate burns; residences forming part of a larger project. r+Excludes garages & small outbuildings.] 1. 2. 3. 4. 5. 6. YES NO § ] Will the project disturb 160 square feet or more of existing building materials? Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition. (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? D D D D (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior to commencing asbestos removal. Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdapcd.org/info/facts/permits.pdf) for typical equipment requiring an APCD permit. D (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school bound a FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: ______________________________ _ BY DATE I I I EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO" APCD COUNTY-HMO APCD COUNTY-HMO APCO · exempts businesses from completing or updating a Hazardous Matenals Business Plan. Other permitting requirements may still apply. County of San Diego -DEH -Hazardous Materials Division --------~--------- LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEAL TH -HAZARDOUS MATERIALS DIVISION Check all that apply: AUTOMOTIVE D Battery Manufacturing/Recycling D Boat Yard D Car Wash D Dealership Maintenance/Painting D Machine Shop D Painting D Radiator Shop D Rental Yard Equipment D Repair/Preventive Maintenance D Spray Booth D Transportation Services D Wrecking/Recycling CHEMICAL HANDLING D Agricultural supplier/distributor D Chemical Manufacturer D Chemical Supplier/Distributor D Coatings/Adhesive D Compressed Gas Supplier/Distributor D Dry Cleaning D Fiberglass/Resin Application D Gas Station D Industrial Laundry D Laboratory D Laboratory Supplier/Distributor D Oil and Fuel Bulk Supply D Pesticide Operator/Distributor CHEMICAL HANDLING D Photographic Processing D Poor Supplies/Maintenance D Printing/Blue Printing D Road Coatings D Swimming Pool D Toxic Gas Handler D Toxic Gas Manufacturer METAL WORKING D Anodizing D Chemical Milling/Etching D Finish-Coating/Painting D Flame Spraying D Foundry D Machine Shop-Drilling/Lathes/Mills D Metal Plating D Metal Prepping/Chemical Coating D Precious Metal Recovery D Sand Blasting/Grinding D Steel Fabricator D Wrought Iron Manufacturing AEROSPACE D Aerospace Industry D Aircraft Maintenance D Aircraft Manufacturing OTHERS AND MISCELLANEOUS D Asphalt Plant D Biotechnology/Research D Chiropractic Office D Co-Generation Plant D Dental Clinic/Office D Dialysis Center D Emergency Generator D Frozen Food Processing Facility D Hazardous Waste Hauler D Hospital/Convalescent Home D Laboratory/Biological Lab D Medical ClinidOffice D Nitrous Oxide (NOx) Control System D Pharmaceuticals D Public Utility D Refrigeration System D Rock Quarry D Ship Repair/Construction D Telecommunications Cell Site D Veterinary Clinic/Hospital D Wood/Furniture Manufacturing/Refinishing ELECTRONICS D Electronic Assembly/Sub-Assembly D Electronic Components Manufacturing D Printed Circuit Board Manufacturing NOTE: THE ABOVE LIST INCLUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES. ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE HAZARDOUS MATERIALS DIVISION (HMO) REVIEW OF BUSINESS PLANS. FOR MORE INFORMATION CALL (858) 505-6880. LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES Businesses, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District. CHEMICAL 47 -Organic Gas Sterilizers 32 -Acid Chemical Milling 33 -Can & Coil Manufacturing COMBUSTION 34 -Piston Internal -Combustion Engines 13 -Boilers & Heaters (1 million BTU/hr or larger) 14 -Incinerators & Crematories 15 -Burn Out Ovens ROCK AND MINERAL 04 -Hot Asphalt Batch Plants 05 -Rock Drills 06 -Screening Operations 07 -Sand Rock & Aggregate Plants \ 44 -Evaporators, Dryers & Stills Processing Organic Materials 24 -Dry Chemical Mixing & Detergent Spray Towers 16 -Core Ovens 20 -Gas Turbines, and Turbine Test Cells & Stands 48 -Landfill and/or Digester Gas Flares 08 -Concrete Batch, CTB, Concrete Mixers, Mixers & Silos 35 -Bulk Dry Chemicals Storage 55 -Chrome Electroplating Tanks COATINGS & ORGANIC SOLVENTS 27 -Coating & Painting 37 -Plasma Arc & Ceramic Deposition Spray Booths 38 -Paint, Stain & Ink Mfg 27 -Printing 27 -Polyester Resin/Fiberglass Operations METALS 18 -Metal Melting Devices 19 -Oil Quenching & Salt Baths 32 -Hot Dip Galvanizing 39 -Precious Metals Refining ORGANIC COMPOUND MARKETING (GASOLINE. ETC) 25 -Gasoline & Alcohol Bulk Plants & Terminals 25 -Intermediate Refuelers 26 -Gasoline & Alcohol Fuel Dispensing ELECTRONICS 29 -Automated Soldering 42 -Electronic Component Mfg FOOD 12 -Fish Canneries 12 -Smoke Houses 50 -Coffee Roasters 35 -Bulk Flour & Powered Sugar Storage SOLVENT USE 28 -Vapor & Cold Degreasing 30 -Solvent & Extract Driers 31 -Dry Cleaning 10 -Brick Manufacturing OTHER 01 -Abrasive Blasting Equipment 03 -Asphalt Roofing Kettles & Tankers 46 -Reverse Osmosis Membrane Mfg 51 -Aqueous Waste Neutralization 11 -Tire Buffers 17 -Brake Debonders 23 -Bulk Grain & Dry Chemical Transfer & Storage 45 -Rubber Mixers 21 -Waste Disposal & Reclamation Units 36 -Grinding Booths & Rooms 40 -Asphalt Pavement Heaters 43 -Ceramic Slip Casting 41 -Perlite Processing 40 -Cooling Towers -Registration Only 91 -Fumigation Operations 56 -WWTP (1 million gal/day or larger) & Pump Station NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITIING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600. HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division } ., NOTES \"IILL ENCOMPASS MO ~ OR SITUATIONS. THE GE• 'IIINGS o.NO SPECIFJCAT ELISE ROTHSCHILD Director <tountp of ~an ilBiego DEPARTMENT OF ENVIRONMENTAL HEALTH FOOD AND HOUSING DIVISION P.O. BOX 129261, SAN DIEGO, CA 92112-9261 Phone: (858) 505-6659 FAX: (858) 505-6824 1 (800) 253-9933 www.sdcdeh.org AMY HARBERT Assistant Director PLAN APPROVAL SHEET OBA: LEGOLAND GARDEN RESTAURANT DATE: 1/17/18 . • u.. 0 UJ a: SITE: I LEGO LAND DR CARLSBAD 92008 PC#: DEH2017-FAMD-004996 BUSINESS O".VNER: MERLIN ENTERTAINMENTS Plans are approved contingent upon the following: I) Department of Environmental Health -Food and Housing Division (DEH-FHD) stamped plans shall be printed on a minimum 11" by 17" size paper to scale. Ensure each sheet is the same size and legible. A paper copy of the plans must be maintained at the jobsite to construct from and available for the Specialist to review at the time of your inspections. 2) Changes to equipment layout, menu, or application must be submitted for approval. Changes made without approval will make the plan approval null and void. 3) Obtain local Building Department and all applicable agencies pennits and approvals PRIOR TO FINAL INSPECTION AND APPROVAL TO OPERATE BY THIS DEPARTMENT. 4) All food and utensil-related equipment shall be certified to applicable sanitation standards by an ANSI accredited testing agency. 5) Upon completion of 50%-80% of construction, call (858) 505-6660 to schedule a mid-inspection. In lieu of a plumbing inspection by DEH, ensure that the plumbing is constructed to these standards: a: Floor sinks shall be installed Yi: exposed and equipped with an appropriate grill cover if no access is provided for cleaning. b. Drain lines shall slope Y4" per foot, shall not exceed 15' in length and shall terminate a minimum of 1" above the floor sink with a legal air gap or otherwise approved by the enforcing agency. Drain lines shall not intersect walkways or door ways. c. No condensate drainage of any kind can drain to the mop sink. d. 3-compartment sinks, preparation sinks, dump sinks, and any other plumbed equipment must drain indirect to a floor sink. e. Grease traps/interceptors, if required by the local waste water authority must be located outside of the food preparation, food storage, or warewashing areas. f. Floor surfaces must be sloped 1 :50 to required floor drains. g. Conduits ofall types shall be installed within walls as practicable. When otherwise installed, they shall be mounted or enclosed in a chase so as to facilitate cleaning. 6) Owners and/or operators must pass an approved and accredited Food Safety Certification course. Proof of successful completion of this course is to be furnished at the final inspection. 7) All equipment is to be in place and functional. At the time when the final inspection is requested, the facility shall have all utilities operational and all refrigeration shall have an ambient air temperature of 38°F or below and shall be equipped with a thermometer accurate to+/-2°F in the warmest section of the unit. 8) Seal all cracks, gaps and crevices in counters, cabinets, around metal flashing, sink backsplashes, around pipes and conduits with silicone sealant. 9) AN AIR BALANCE REPORT IS REQUIRED IF THE FACILITY HAS VENTILATION HOODS. 10) ANY FOOD PROCESSING AREAS MUST BE COMPLETELY ENCLOSED. OPERABLE WINDOWS, MOVEABLE WALL PANELS, GARAGE ROLL-UP DOORS, OR OTHER MEANS OF RENDERING FOOl::f PROCESSlNG AREAS NOT FULLY ENCLOSED ARE NOT APPROVED. t 1) Be advised, applicable jurisdiction requirements that result in changes to approved.·plans::may1 • re·gUi.re· revisions to the Department of Environmental Health plans. Plans reviewed by: C. PENN, REHS CALL (858) 505-6660 AT LEAST 10 WORKING DAYS IN ADVANCE TO SCHEDULE MID AND FINAL INSPECTIONS. A FINAL INSPECTION MUST BE CONDUCTED AND AN ENVIRONMENTAL HEALTH PERMIT SHALL BE ISSUED PRIOR TO OPENING AND OPERATING THIS FOOD ESTABLISHMENT. "Environmental and public health through leadership, partnership and science" NEW AREA ti ~ER~EO BY I 'VE:DBYI "'AN~