Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1000 AVIARA PY; 104; CB061199; Permit
07-31-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB061199 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: EDWARD YAMADA 550 SO. HOPE ST 90071 213-623-2164 1000 AVIARA PY CBAD St: 104 Tl Sub Type: COMM 2120407000 Lot#: 0 $199,463.00 Construction Type: V1 Reference #: COMERICA BANK - 4,284 SF Tl Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check*: ISSUED 05/03/2006 JMA 08/04/2006 08/04/2006 TP Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $854.56 Meter Size $0.00 Add'l Reel. Water Con. Fee $555.46 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $41.89 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $17,816.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees HMP Fee TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $3,630.23 $0.00 $0.00 $0.00 $1,904.00 $0.00 $48.00 $770.00 $37.00 $0.00 $1,566.15 $0.00 $0.00 ?? $27,223.29 Total Fees:$27,223.29 Total Payments To Date:$27,223.29 Balance Due:$0.00 BUILDING PLANS NY IN STORAGE ATTACHED Inspector: FINAL APPROVAL Date: .Clearance: NOTICE: Please take NOTICE that approval of your project includes the Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul theirjmposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any lees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 1 ; PROJECT INFORMATION FORQFFICE USE ONLY PLAN CHECK NO. Plan Ck. Deposit Validated By _ Date ^ Address (include BJdg/Suite #) Legal Description Business Name (at this address) Lot No. Subdivision Name/Number ? Description of Work ONTACT PERSON (if different frorrvappicant) State/Zip / Telephone # gent for Owner Name Address / City 3. APPLICANT D Contractor D.-Agent for'Contractor •, D Owner " A&. Name ' 4. -PROPERTY OWNER Address City State/Zip Telephone # te/Zip / Telephone #'State/ZipName Address ' City L5. ," cbNTRACJOR^jCpiyiPANMAME,,';:.,,^...,',, j§£^ _i_ ''-^ ' .JH , . ,,,^,.<,, '^, ,,^^, ..... ^^ ...Hi/., _«.„ ii- :/iL'. (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031 .5 by any applicant for a permit subjects the applicant to a ciyi|£enalty of not more than five hundred dollars B500]). Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name State License # _ 6. Address City Telephone # WORKER'S COMPENSATION :t .-. .. ./,: . :. ...-„• •*:;-.:,-.**." 4'JOSU.. ~ --A. • : ,.J*.«X, *f-£U-* . ^~ , ,.~*«*K sl^'.- "~. . . '. .'J^ . .','V.^Mi.:,.Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: State/Zip I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secur^worl^rs' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand / dollars($100,000), in addUMn tmU^cost ot-cffrpensalion, damages are provided for in Section 3706 of the Labor Code, interest and attorney's fees. SIGNATURE ^L^ £/ , DATE ff~ ¥~ O *? 7.'""70WNE¥SufL'DER'DECLARATlON" "~ ' ' '" ' i, ' ']'"""' '"^" ~V ' ' "' -f ' I hereby affirm that I am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES D NO 2. I (have/have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / /ontractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Page 2 of 2 .COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY- ~"f Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1 ,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code). LENDER'S NAME _ LENDER'S ADDRESS 9. APPLICANT CERTIFICATION' ~~ """ ," """;'," '<{ . "rx" ™7" """" " "^ " "~~ ' ~*~ ~ """ "T' I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND OSHA: An OSHA permit is required for excavations of 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date.of such permit or if the building or work authorized by such permit is suspended or abandoned at anytime after the work is commenced for a period of 180?days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE I//IJ4 /fl / DATE WHITE: File YELLOW: Applicant PINK: Finance Inspection List Permit*: CB061199 Type: Tl COMM COMERICA BANK - 4,284 SF Tl Date Inspection Item 07/30/2007 89 Final Combo 01/30/200789 Final Combo 01/30/2007 89 Final Combo 09/21/2006 89 09/19/2006 14 09/19/200634 09/19/200644 09/07/2006 14 09/07/2006 24 09/07/2006 34 09/07/2006 44 08/31/2006 34 08/09/2006 14 08/09/2006 34 08/07/2006 14 08/07/2006 21 08/07/2006 31 08/07/2006 34 Final Combo Frame/Steel/Bolting/Weldin Rough Electric Rough/Ducts/Dampers Frame/Steel/Bolting/Weldin Rough/Topout Rough Electric Rough/Ducts/Dampers Rough Electric Frame/Steel/Bolting/Weldin Rough Electric Frame/Steel/Bolting/Weldin Underground/Under Floor Underground/Conduit-Wirin Rough Electric Inspector TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP Act Fl PA PA CO AP AP AP PA WC PA PA PA AP AP AP AP AP AP Comments ___ OK TO FINAL TO EXTEND PERMIT UNTIL PLANNING APPROVAL PARTL APPVL. TO EXTEND TILL PLANNING APPVS. N/COMP. OK TO OCCUPY T-CEIL CEIL LITES DUCTS, HPS T-CEIL CEIL LITES DUCTS, H P s EMR WALLS Tuesday, July 31, 2007 Page 1 of 1 City of Carlsbad Bldg Inspection Request For: 08/31/2006 Permit* CB061199 Title: COMERICA BANK - 4,284 SF Tl Description: Inspector Assignment: TP Type: Tl Sub Type: COMM Job Address: 1000AVIARAPY Suite: (^W£> Lot 0 Location: APPLICANT EDWARD YAMADA Owner: Remarks: Phone: 6195203860 Inspector: Total Time: CD Description 34 Rough Electric Act Comment Requested By: STEVE Entered By: CHRISTINE Comments/Notices/Hold Associated PCRs/CVs Original PC# Inspection History Date Description Act Insp Comments 08/09/2006 14 Frame/Steel/Bolting/Welding AP TP 08/09/2006 34 Rough Electric AP TP 08/07/2006 14 Frame/Steel/Bolting/Welding AP TP WALLS 08/07/2006 21 Underground/Under Floor AP TP 08/07/2006 31 Underground/Conduit-Wiring AP TP 08/07/2006 34 Rough Electric AP TP EsGii Corporation In Partnership with government for (Building Safety DATE. August 2, 20O6 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 06-1199 SET: IV PROJECT ADDRESS. 1000 Aviara Parkway Suite 10O PROJECT NAME: Comerica - TI Q APPLICANT a PLAN REVIEWER a FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. . XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ;js The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Xj Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person X] REMARKS: OK to issue with the applicant placing the P & E sheets from Set II into Set III. This will create a complete Set IV. By: Bryan Zuppiger Esgil Corporation D GA D MB L~] EJ D PC Enclosures: Sets II & LOG tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with government for (Builifing Safety DATE: July 18, 2006 O-J£ELICANT JURISDICTION: City of Carlsbad a PLAN REVIEWER . • a FILE PLAN CHECK NO.: 06-1199 SET: HI PROJECT ADDRESS: 1000 Aviara Parkway Suite 10O PROJECT NAME: Comerica - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X3 The applicant's copy of the check list has been sent to: Interior Architects / Edward Yamada 550 S. Hope Street Suite 1700, Los Angeles, CA 90071 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Edward Yamada Telephone #: 213-623-2164 : Date contacted: 1 ft4/0* (byd-ty Fax #: 213-623-2139 Mail Telephone - Fax \/ In Person 1 REMARKS: By: Bryan Zuppiger Enclosures: Esgil Corporation D GA D MB D EJ D PC 07/11/06 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Citj^of Carlsbad 06-1199 "July 18, 2OO6 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: O6-1199 PROJECT ADDRESS: 1000 Aviara Parkway Suite 100 SET: III DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 07/11/06 July 18, 2006 REVIEWED BY: Bryan Zuppiger ' FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit new complete sets of prints to: See #1 next sheet. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo City^of Carlsbad 06-1199 Xliily 18, 20O6 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 4. Please clarify the plans it appears the main entry will be altered? Please provide complete plans and details. Will the building envelope be altered (new storefront glazing?) Please provide the complete energy package for the alteration to the building envelope (the removal of the existing window and the installation of a new storefront system is considered an alteration to the building envelope). I am unfamiliar with a 50 ft2 exception please state the page number and manual title or submit ENV sheets with insulation requirements. The person responsible for their preparation must sign all final sheets of plans. (California Business and Professions Code). Final structural plans, specifications and calculations must be signed and sealed by the engineer or architect licensed by the State of California who is responsible for their preparation. Please specify the expiration date of license. (California Business and Professions Code). To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation. Thank you. 4? ", • '*•EsGil Corporation In Partnership with government for Quitting Safety DATE: 6/7/06 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 06-1199 SET: II PROJECT ADDRESS: 1000 Aviara Parkway Suite 100 PROJECT NAME: Comerica - TI PLAN REVIEWER a FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Interior Architects / Edward Yamada 550 S. Hope Street Suite 1700, Los Angeles, CA 90071 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Edward Yamada Telephone*: 213-623-2164 Date contacted: 6/7/6^(by^-^ Fax #: 213-623-2139 Mail Telephone.^/"^ Fax \/\r\ Person REMARKS: By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 5/31/06 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 City^of Carlsbad 06-1199 6/7/06 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: 06-1199 PROJECT ADDRESS: 1000 Aviara Parkway Suite 1OO SET: II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 5/31/06 6/7/06 REVIEWED BY: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit new complete sets of prints to: B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo City^of Carlsbad 06-1199 6/7/06 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 4. Please clarify the plans it appears the main entry will be altered? Please provide complete plans and details. Will the building envelope be altered (new storefront glazing?) Please provide the complete energy package for the alteration to the building envelope (the removal of the existing window and the installation of a new storefront system is considered an alteration to the building envelope). 6. Please provide the ICBO listing number for the fabricated modular vault system. Please provide a deferred submittal block on the cover sheet of the plans and indicate the Structural design, installation and Special Inspection for the new vault system shall be a deferred submittal or provide complete plans, details, calculations and a complete Special Inspection form. 7. Please provide evidence the manufacturer is an approved fabricator with the City of Carlsbad. See comment 6. 8. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.2. • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM REQUIRED? REMARKS FIELD WELDING EXPANSION/EPOXY ANCHORS 9. When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to City^of Carlsbad 06-1199 "6/7/06 issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. See comment 6. 10. Please provide the complete MECH-1-C energy package. Please have the principle designer check the appropriate box(s) in the Statement of Compliance System Acceptance section of the MECH-1 -C documents. 11. Please clarify the MECH-1-C energy documents the new AC is not shown? (This unit does not comply as process cooling and must be shown in the energy compliance forms). Please provide the calculated heating and cooling information on the MECH forms. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation JCANT PLAN REVIEWER a FILE ^ In Partnership -with government for <Buit<£ing Safety DATE: 5/12/06 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 06-1199 SET: I PROJECT ADDRESS. 1000 Aviara Parkway Suite 100 PROJECT NAME: Comerica - TI [~~1 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Interior Architects / Edward Yamada 550 S. Hope Street Suite 1700, Los Angeles, CA 90071 Esgil Corporation staff did not advise the applicant that the plan check has been completed. IXI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Edward Yamada Telephone #: 213-623-2164 Date contacted: ///JY^(bv:J$^) Fax #: 213-623-2139 Mail Telephone ^^ Fax -^ In Person REMARKS: By: Doug Moody Esgil Corporation D GA D MB D EJ Enclosures: PC 5/4/06 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576 City of Carlsbad 06-1199 5/12/O6 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: O6-1199 OCCUPANCY: B TYPE OF CONSTRUCTION: IFR ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 5/3/06 DATE INITIAL PLAN REVIEW COMPLETED: 5/12/06 JURISDICTION: City of Carlsbad USE: Bank ACTUAL AREA: 4284sf STORIES: 1 HEIGHT: OCCUPANT LOAD: 65 DATE PLANS RECEIVED BY ESGIL CORPORATION: 5/4/06 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list for a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw.dot City of Carlsbad 06-1199 5/12/O6 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 2. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2004 edition of the California Electrical Code and the 2002 NEC. 3. On the first sheet of the plans indicate: • The floor area of the remodeled area to be 4284sf 4. Please clarify the plans it appears the main entry will be altered? Please provide complete plans and details. Will the building envelope be altered (new storefront glazing?) 5. Provide a section view of the new soffits. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". b) Method of attaching top to the structure and lateral bracing. c) Show height of the soffit from floor, soffit to roof framing or floor framing. 6. Please provide the ICBO listing number for the fabricated modular vault system. 7. Please provide evidence the manufacturer is an approved fabricator with the City of Carlsbad. 8. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.2. • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. City of Carlsbad 06-1199 5/12/06 ITEM REQUIRED? REMARKS • FIELD WELDING • EXPANSION/EPOXY ANCHORS 9. When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. 1 0. Please have the principle designer check the appropriate box(s) and complete the Statement of Compliance System Acceptance section of the LTG-1-C part 4 of 4 documents. 1 1 . Please complete the LTG-1-C part 2 of 4 mandatory automatic controls portion of the LTG-1-C forms. 12. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 13. Please provide the required LTG-9-C form for the track lighting. 14. Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". 15. Please revise the panel schedule for panel HL1 to show the over-current devise feeding the new 75 KVA transformer. 16. Please revise the single line diagram the conduit for panels HP1 and HP2 are undersized. 17. Please provide the complete MECH-1-C energy package. 18. Please clarify the MECH-1-C energy documents the new AC is not shown? (This unit does not comply as process cooling and must be shown in the energy compliance forms). 19. Please imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. 20. Please revise the plumbing plans to show the required clean-outs per section 707 of the UPC. 21 . Show 1/4" per 12" slope on drain and waste lines. UPC Section 708.0. City of Carlsbad 06-1199 5/12/06 22. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B.2. These requirements apply as follows: a) Existing sanitary facilitfes that serve the remodeled area must be shown to comply with all accessibility features. 23. It is unclear from the plans if the restrooms servicing the tenant improvement are disabled accessible, please provide a dimensioned restroom plans showing the restroom to be accessible compliant. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad O6-1199 5/12/06 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No. 06-1199 Job Address or Legal Description 1000 Aviara Parkway Suite 100 Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet. The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit. Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special inspectors for the type of construction for which they are certified. The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department. The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code. The Special inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect. The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes. The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved. The final inspection approval will not be given until all Special inspection reports have been received and approved by the City of Carlsbad building department. Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet. (over) City of Carlsbad 06-1199 5/12/06 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: PLAN CHECK NUMBER: OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special inspector(s) as required by Uniform Building Code (UBC) Section 1701.1 for the construction project located at the site listed above. UBC Section 106.3.5. Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106.3.5 for the construction project located at the site listed above. Engineer's/Architect's Seal & Signature Hare Signed 1. List of work requiring special inspection: CH Soils Compliance Prior to Foundation Inspection [>3 Field Welding D Structural Concrete Over 2500 PSI D High Strength Bolting [H Prestressed Concrete £3 Expansion/Epoxy Anchors [H Structural Masonry []] Sprayed-On Fireproofing EH Designer Specified Q Other 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: A. B. C. 3. Duties of the special inspectors for the work listed above: A. B. C. Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site. City of Carlsbad 06-1199 S/12/06 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 06-1199 PREPARED BY: Doug Moody DATE: 5/12/06 BUILDING ADDRESS: 1000 Aviara Parkway Suite 100 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: IFR BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 4284 cb Valuation Multiplier 46.56 3y Ordinance Reg. Mod. VALUE ($) 199,463 199,463 Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: [H Repetitive Fee Repeats Complete Review D Other j—I Hourly Structural Only Hour Esgil Plan Review Fee $854.56 $555.46 $478.55 Comments: Sheet 1 of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$10,000.00) DATE 7 C / NANTIMPROVEMEI PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE DATE Oocs/Misforms/Planning Engmeenng Approvals a ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET stimate based on unconfirmed information from applicant. Calculation based on building plancheck plan submittal. - So^Bdg. Permit No.Address: Prepared by:.Date:Checked by.Date: EDU CALCULATIONS: List types and square footages for all uses. Types ofOse: V^*^- c>\^ Sq. Ft/Units: Types of Use:.Sq. Ft./Units:_ ADT CALCULATIONS: List types and square footageafor all uses. Types of Use:Sq. Ft/Units:. EDU's: EDU's:. ADT's: _ ADT's: _ FEES REQUIRED:^ WITHIN CFD: ETYES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) [IJ^PARK-IN-LIEU FEE ' ^FEE/UNIT: PARK AREA & #:. X NO. UNITS: 2. TRAFFIC IMPACT FEE ADT's/UNITS:FEE/ADT: 3. BRIDGE AND THOROUGHFARE FEE (DIST. #1 DIST. #2 DIST. #3 ADT'sAJNITS: ' FACILITIES MANAGEMENT FEE UNIT/SQ.FT.: 5. SEWER FEE EDU's: ( '& 1 FIT AREA: EDU's: X FEE/ADT:_ ZONE: 5 X FEE/SQ.FT./UNIT:_ X FEE/EDU: FEE/EDU:=$_ LATERAL ($2,500) TDRAINAGE FEES PLDA : ACRES: X . POTABLE WATER FEES UNITS CODE CONNECTION FEE HIGH. FEE/AC: '/LOW =$_ =$_ DNO METER FEE SDCWA FEE SDCWA FEE F:\FEE CALCULATION WORKSHEET.doc 1 of 2 Rev. 7/14/00 ISDD PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Planner Erin Endres to Address Phone (760) APN: Type of Project & Use:_ Zoning: General Plan: CFD (in/out) #_Date of participation:. Net Project Density:.DU/AC Facilities Management Zone: Remaining net dev acres:. Circle One (For non-residential development: Type of land used created by this permit: ; ) Legend; E3 Item Complete Q Item Incomplete - Needs your action Environmental Review Required: YES NO . TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO. NO. PROJECT NO. ; • YES NO. DATE TYPE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: K] D D Coastal Zone Assessment/Compliance \ Project site located in Coastal Zone? YES NO CA Coastal Commission Authority? YES. NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): ^ y Coastal Permit Determination Form already completed? YES_ If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: NO D D Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. YES NOmclusfonary Housing Fee, required: _ (Effective date of Inclusionary Housing Ordinance -May21,f1,993.) /. .. 4 V ,-? ?' . . •'/;j%jv- ;.:;., ,t j^J •*:' ->-•"" -.--* • ' -' ^ Data Entry Completed? YES _ NO . . . \ .;.. j , , > . ' (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Site Plan: n D 1- Provide a fully dimensional site plan drawn to scale. Show: North arrow,, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). • ' • .. </;. Q Q] 2. Provide legal description of property and assessor's parcel number. " . '"- Q D D TSDD > a a Policy 44- Neighborhood Architectural Design Guidelines 1. Applicability: YES_ NO 2. Project complies YES_NO Zoning: 1 . Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: 2. Accessory structure Front: Interior Side: Street Side: Rear: Structure separation 3. Lot Coverage: Required Required Required Reauired Reauired setbacks: Required Required Required Reauired : Reauired Reauired Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown 4. Height:Required Shown Spaces Required.Shown5. Parking: (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments reauihad/o 1 JherlotiNaumt Correction #2 — Is there anv proposed roohfiounted equipment associated with this building permit? If so. will the equipment be screened bv an existing parapet wall or is new screening material required? Please see the attached handouts for examples. v^ , / / OK TO ISSUE AND ENTERED APPROVAL (No CMPUTER H:\AOMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Carlsbad Fire Department Plan Review Requirements Category: TI, COMM Date of Report: 05-23-2006 Reviewed by: Name: Address: EDWARD YAMADA 550 SO. HOPE ST LOS ANGELES, CA 90071 Permit #: CB061199 . Please review Job Name: COMERICA BANK - 4477 SF TI Job Address: 1000 AVIARAPY CBAD adequately conduct a review to determine Conditions: Cond: CON0001373 [NOT MET] Approved: This project has been reviewed and approved for the purpose of issuance of a building permit. This approval is subject to field inspections, any required test, fire department notations, conditions in correspondence and compliance with all applicable codes and regulations. This approval shall not be to held to permit or approve the violation of any law.. License Detail fr » '» Page 1 of2 California Home Friday, Aug License Detail Contractor License # 674069 DISCLAIMER A license status check provides information taken from the CSLB license data base. Before on this information, you should be aware of the following limitations: • CSLB complaint disclosure is restricted by law (B&P 7124.6). If this entity is subject tc complaint disclosure, a link for complaint disclosure will appear below. Click on the lin button to obtain complaint and/or legal action information. • Per B&.PJ7071.17, only construction related civil judgments reported to the CSLB are disclosed. • Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. • Due to workload, there may be relevant information that has not yet been entered ont Board's license data base. Extract Date: 08/04/2006 * * * Business Information * * * RENO CONTRACTING INC 1450FRAZEERD#100 SAN DIEGO, CA 92108 Business Phone Number: (619) 220-0224 Entity: Corporation Issue Date: 07/08/1993 Expire Date: 07/31/2007 * * *License Status * * This license is current and active. All information below should be reviewed. *** Classifications *** Class B Description GENERAL BUILDING CONTRACTOR * * *Bonding Information * * * CONTRACTOR'S BOND: This license filed Contractor's Bond number 73931 in the amc $10,000 with the bonding company http://www2.cslb.ca.gov/CSLB_LIBRARY/License+Detail.asp 08/04/2006 License Detail Page 2 of 2 AMERICAN CONTRACTORS INDEMNITY COMPANY. Effective Date: 01/01/2004 Contractor's Bonding History BOND OF QUALIFYING INDIVlDUAL(l): The Responsible Managing Officer (RMO)-MAi JAMES RENO certified that he/she owns 10 percent or more of the voting stock/equity ( corporation. A bond of qualifying individual is not required. Effective Date: 12/24/1993 *** Workers Compensation Information *** 1 This license has workers compensation insurance with the REDWOOD FIRE AND CASUALTY INSURANCE CO (2357-2) Policy Number: W5834379 Effective Date: 08/01/2005 Expire Date: 08/01/2006 Workers Compensation History Personnel listed on this license (current or disassociated) are listed on other licet Personnel List Other Licenses BLicense Number Request [Contractor Name Request •Personnel Name Request Salesperson Request [Salesperson Name Request © 2006 State of California. Conditions of Use Privacy Policy http://www2.cslb.ca.gov/CSLB_LIBRARY/License+Detail.asp 08/04/2006 I D ? ce £ LLJ So _OO I-