Loading...
HomeMy WebLinkAbout1000 AVIARA PY; ; CB112651; Permit01-25-2012 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit PermitNo: CBl 12651 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 1000 AVIARA PY CBAD Tl Sub Type: 2120407000 Lot#: $20,503.00 Construction Type: (RofsroncG ^* AVIARA HOLDINGS-CONSTRUCT CARPORTS FOR NINE SPACES COMM 0 NEW Applicant: FIANCO JOANNE STE 220 1000 AVIARA PARKWAY CARLSBAD CA 92011 760-602-9640 Status: ISSUED Applied: 12/16/2011 Entered By: KG Plan Approved: 01/25/2012 Issued: 01/25/2012 Inspect Area: Plan Check#: Owner: KELLY CORPORATE CENTER II C L L C C/O THE ALLEN GROUP 5330 CARROLL CANYON RD #200 SAN DIEGOCA 92121 Building Pemiit $234.67 Meter Size Add'l Building Pennit Fee $0.00 Add'l Reel. Water Con. Fee $0.00 Plan Check $164.27 Meter Fee $0.00 Add'l Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $4.31 PFF (3105540) $0.00 Park Fee $0.00 PFF (4305540) $0.00 LFM Fee $0.00 License Tax (3104193) $0.00 Bridge Fee $0.00 License Tax (4304193) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $0.00 BTD #3 Fee $0.00 Traffic Impact Fee (4305541) $0.00 Renewal Fee $0.00 PLUMBING TOTAL $0.00 Add'l Renewal Fee $0.00 ELECTRICAL TOTAL $0.00 Other Building Fee $0.00 MECHANICAL TOTAL $0.00 Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green BIdg Stands (SB1473) Fee $1.00 HMP Fee ?? Fire Expedited Plan Review $340.00 Green BIdg Standards Plan Chk ?? TOTAL PERMIT FEES $744.25 Total Fees: $744.25 Total Payments To Date: $744.25 Balance Due: $0.00 Inspector: (/>^^ FINAL API Date: m VAL Clearance: NOTICE: Please take NOTICE ttial approval of your project includes the "Imposition" of fees, dedications, resen/ations, or other exacttons hereafter collectively referred to as lees/exactlons." You have 90 days from tfie date tliis pemiit was Issued to protest imposition of these fees/exactions. If you protest tfiem, you must follow the protest procedures set forth In Government Code Section 66020(a), and file the protest and any other required Information with the City Manager for processing In accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their Imposition. You are hereby FURTHER NOTIFIED that your right to protest ttie specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or sen/ice fees In connection with this project. NOR DOES IT APPLY fo any fees/exactions of which vou have oreviouslv been given a NOTICE similar to this, or as to which the statute of limitations has orevtouslv othenvise exoired. ^ CITY OF CARLSBAD Building Permit Appiication 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax: 760-602-8558 www.carlsbadca.gov Plan Check No {>./^//20^/ Est. Value ^^5P3 Plan Ck. Deposit ilp^^ ^7 Date 2S SWPP JOB ADDRESS SUITE#/SPACE#/UNIT# CT/PROJECT # PHASE # # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TVPE OCC. GROUP DESCRIPTION OF WORK: /nc/ude Square /^eet ofA/Tected Area(s; EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YES • # NOD AIR CONDITIONING YES •NOD FIRE SPRINKLERS YES • NOO NAME (Secondaiy Contact) ADDRESS • ri I 1 CITYA I 1 I STATE ZIP ADDRESS CITY STATE ZIP PHONE , FAX _ , PHCNE irasiL FAX ^-CfOJCKOO £lS^Sl^(\ahLH • 66YA EIVIAIL PROPERTV OWNER NAME/ . , • i . /aro AvrcurA. UoidAms U^^ . ADDRESS Z J . ir~ CONTRACTOR BUS. NAUE 6g?rs- t2i/i/evwDods f/cwy ADDRESS I i CITY STATE FAX £.ir STATE ZIP PHONE EMAIL ARCH/DESIGNER NAME & ADDRESS CnYBlJS.LIC.#__ _ 5-7/3 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicantfor such permit to file a signed statement that he is licensed pursuant to the provisions ofthe Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civii penalty of not more than five hundred dollars {$500)). WORKERS' COMPiNSATlOM Workers' Compensation Declaration: //lereby affinn under penalty of peijuiy one ofthe following declarations: ^ I have and will maintain a certificate of consent to self-insure for woriceis' compensation as provided by Section 3700 of the Labor Code, for tiie performance of tlie woil< for wtiich this pennit is issued. G I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this pemiit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. 'TflOLjeJ.e/'^ Policy No. t/3 V73/V) Zx'Z^ Expiration Date '7/11' This section need not be completed if the permit is for one hundred dollars ($100) or less. n Certificate of Exemption: I certify that in the perfomiance of the work for which this pemiit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Califbrnia. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employerto criminal penalties and civil fines up to one hundred thousand dollars (&iOO,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attomey's fees. JB^ CONTRACTOR SIGNATURE •AGENT DATE OWMER'SUILOER DECLARATION / /iere/)y affinn that I am exempf from Condacfor's Ucense Law for the foiiowing reason: • I, as owner of the property or my empioyees with wages as their sole compensation, wiil do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvemenls are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not buiM or improve for the purpose of sale). IJ'^I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's Ucense Law). • I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for constnjction of the proposed property improvement • Yes • No 2.1 (have / have not) signed an application for a building pemiit for the proposed woik. 3.1 have contracted with the following peison (firm) to provide the proposed constnjction (inciude name address / phone / contractors' license number): 4.1 plan to provkle portions of the work, but I have hired the following person to coordinate, supeivise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indk;ated (include name / addiess / phone / type of work): I PROPERTY OWNER SIGNATURE O^CGENT DATE |2^)$'(( i com[p:teTe .THIS SECTION FOR NON-UESIBBHTIAL BUILDING PERMITS ONLY Is the applicant or futuro buiiding oaupant requiied fo submit a business pian, acutely hazanlous materials registration fomi or risk management and prevention program under Sections 25505,25533 or 25534 of the Pre^ey-Tanner Hazardous Substance Account Act? OYes ONo Is ihe applicant or futuro building occupant required fo obtain a pemiit from the air pollution control district or air quality management distrk^ OYes nNo Is the facility to be constmcted within 1,000 feet of the outer boundaiy of a school site? • Yes • No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affinn that there Is a constnjction lending agency for the perfbmiance of the work this pennit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address APPLICANT CERTIFICATION I certif that I have read the applnation and state thatthe above infoimatkm is conect and thatthe infonnatkm on the plans is accurate. I agree to comply with all Oily ordinances and State laws lelating to building constniction. I heieby authorize representative ofthe City of Cailsbad to enter upon Ihe above mentbned propeity for inspection puiposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL UABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: Al OSHA pemnit is required for excavatkins over S'C deep and demoHtkxi or constructbn of stmctures over 3 stories in heighl EXPIRATION: Every peimit issued by the Building Oflicial under the provisbns of this Code shall expire by limitation and beconne null and vokl If the buiUing or woik aulhorized by such pennit is not commenced within 180 days from the date of such pemilt or If the buiUing or woik authorized by such pemiit is suspended or abandoned at any time after the vwri^ Is commenced fbr a period of 180 days (Sectbn 106.4.4 Uniform Building Code). > APPLICANT'S SIGNATURE DATE 1 cinMeiiMMi final Billdlig inspacdra Dept: Building Engineering Planning CIVIWD St Lite, Plan Check #: Permit #: CB112651 ProjectName: AVIARA HOLDINGS-CONSTRUCT CARPORTS FOR NINE SPACES Address: 1000 AVIARA PY Lot: Contact Person: JOANNE Phone: 7604709108 Sewer Dist: CA Water Dist: CA Date: 02/24/2012 Permit Type: Tl Sub Type: COMM Inspected By: Inspected By: Date Inspected fApproved 2^ Inspected By: Date Inspected:, Date Inspected:. Approved: . Approved: Disapproved: Disapproved: Disapproved: Comments: City ofCarlsbad BIdg Inspection Request For: 03/05/2012 Permit* CB112651 Title: AVIARA HOLDINGS-CONSTRUCT Description: CARPORTS FOR NINE SPACES Inspector Assignment: MC 1000 AVIARA PY Lot: Type:TI Sub Type: COMM Job Address: Suite: Location; APPLICANT FIANCO JOANNE Owner: 1000 AVIARA HOLDINGS LLC Remarks: 760-602-9640 Phone: 7604709108CELL Inspector; f^Q Total Time: CD Description 19 Final Structural Requested By; JOANNE FRANCO Entered By; CHRISTINE Act Comments Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Inspection Historv Date Description Act Insp Comments 02/24/2012 89 Final Combo CO MC COIVIPLETE ALL WORK 02/14/2012 11 Ftg/Foundation/Piers AP MC 5 COLUMN FTGS AND STEEL REGISTERED INSPECTOR'S DAILY REPORT Job Humbar D«to ^ H^Structural Steel Assembly • Quality Control • Fireproofing • Epoxy Anchors • Asphalt • Other TYPE OF INSPECTION REQUIRED 'jopAdSfMs" • Reinforced Concrete • Post Tensioned Concrete • Structural Masonry Job Nuis crty P«nnit Numbsr ArohltMt Issuod By Typo of Struotura /^C CA'^fOf^ ST^cTuiz^ Matorial Description (type, grada, souro«) J- Engbwtr _ B7£>/8' {^i-f^^irr^oPB-s SubDon)notor ' Inipoelors Ntma INSPECTION SUMMARY -LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS. ETC. INCLUDES INFORMATION ABOUT AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED. NUMBER. TYPE AND IDENTIFICATION NUMBERS OF SAMPLES TAKEN. STRUCTURAL CONNECTIONS (WELD MADE H.T. BOLTS TORQUED) CHECKED. ETC. KJgLps, Q^t^Mzis gjgMo^^ ^Qg-ho VA/feu>»WW , yuiUJi^ \A/eU>&> I tVfeLPER-- CAMpcS AtOAtz/> AUS pl.t, PU? SHW'**'l55*k)^SP l^p SAMPLES COMCRETg MORTAR BLOCK PRISMS PgWSITY PAGE OF CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the reported work, unless otherwise noted. Is In confomiance with the approved plans, speciflcations, and applicable sections of the governing building laws. /. SL TIME IN TIMEOUT REG.HOU(« 0T1.6X 0T2X All inspections basod on a minimum of 4 houre. Over4 houre = 6 houra minknum. Any Inspediora eadending pat noon will bs chaiged as ui 8 hour ninlmuin. APPROVED BY: ^ Inspeclions eadendng pat noon will bs chaigod as ui 8 hour ninlmuin. Signature of Special CertfRcalion Numbsr EsGii Corporation In (Partnership tvitli government for (BuUding Safety DATE: JAN. 17, 2012 JURISDICTION: CARLSBAD PLANCHECKNO.: 11-2651 SET; II PROJECT ADDRESS: 1000 AVIARA PARKWAY PROJECT NAME: NINE-SPACE CARPORT O-AeELICANT JURI^ • PLAN REVIEWER • FILE XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: Joanne Franco 1000 Aviara Parkway, Suite 220, Carlsbad, CA 92011 EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Joanne Telephone #: 760-602-9640x1 Date contacted: (by:) Email: jfranco@assetsignature.com Fax #: 760-683-6060 Mail Telephone Fax In Person • REMARKS: By: ALI SADRE EsGil Corporation • GA • EJ • PC Enclosures: 1/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 r EsGii Corporation In Partnership •with government for (BuiCeCing Safety DATE: DEC. 21, 2011 • APPLICANT JURISDICTION: CARLSBAD • PETnTREVIEWER • FILE PLANCHECKNO.: 11-2651 SET; I PROJECT ADDRESS: 1000 AVIARA PARKWAY PROJECT NAME: NINE-SPACE CARPORT I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ^ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. PLEASE SEE BELOW I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. ^ The applicant's copy of the check list has been sent to: Joanne Franco 1000 Aviara Parkway, Suite 220, Carlsbad, CA 92011 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Joanne Telephone #: 760-602-9640x1 Date contacted:/2|2» (by:)v^c. Email: jfranco(gassetsignature.com Fax #: 760-683-6060 t Mail ^ Telephone Fax-^ In Person XI REMARKS: #1): On Sheet S-1, note the floor area of the carport = 1,600 s.f.; #2): Note on site plans that there is an existing covered HC parking on site subject to field verification; otherwise, provide a new HC complying parking space on site plans. [Please submit three sets of stamped, signed and sealed plans to the city for review and approval]. By: ALI SADRE Enclosures: EsGil Corporation • GA • EJ • PC 12/19 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CARLSBAD PLANCHECKNO.: 11-2651 PREPARED BY: ALI SADRE DATE: DEC. 21, 2011 BUILDING ADDRESS: 1000 AVIARA PARKWAY BUILDING OCCUPANCY: U TYPE OF CONSTRUCTION: V-B BUILDING PORTION AREA (Sq.Ft.) Valuation Multiplier Reg. Mod. VALUE ($) CARPORTS 1600 Air Conditioning Fire Sprinklers TOTAL VALUE 20,503 Jurisdiction Code CB By Ordinance BIdg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: D Repetitive Fee Repeats E! Complete Review • Other j—J Hourly EsGii Fee $234.67 $152.54 • Structural Only Hr. @ * $131.42 Comments: Sheet 1 of 1 macvalue.doc + RESPONSE Corporation /« Partnership with government for (Building Safety DATE: DEC. 21, 2011 • APPLICANT • JURIS. JURISDICTION: CARLSBAD • PU\N REVIEV • FILE PLANCHECKNO.: 11-2651 SET:! PROJECT ADDRESS: 1000 AVIARA PARKWAY PROJECT NAME: NINE-SPACE CARPORT [~1 The plans transmitted herewith have been corrected where necessary and substanti with the jurisdiction's codes. \ I The plans transmitted herewith wili substantially comply with the jurisdiction's buildin when minor deficiencies identified below are resolved and checked by building depg Fl The plans transmitted herewith have significant deficiencies Identified on the enclose and should be corrected and resubmitted for a complete recheck. ^ The check list transmitted herewith is for your infonnation. The plans are being hekl Corporafion until corrected plans are submitted for recheck. PLEASE SEE BELOW I I The applicant's copy of the check list is enclosed for the jurisdiction to fonA/ard to the contact person. ^ The applicant's copy of the check list has been sent to: Joanne Franco 1000 Aviara Parkway, Suite 220, Carlsbad, CA 92011 I I EsGil Corporation staff did not advise the appiicant that the plan check has been co EsGil Corporation staff did advise the applicant that the plan check has been compli Person contacted: Joanne Telephone #: 760-602 Date contacted: (by:) Email: jfranco@assetsignature.com Fax #: 760-68: Mail Telephone Fax In Person 3 REMARKS: #1): On Sheet S-1, note the floor area of the carport = 1,600 s.f.; #2}: plans that there is an existing covered HC parking on site subject to field verification provide a new HC complying parking space on site plans. {Please submit three sets signed and sealed plans to the city for review and approval]. NOTE UKS BGeH KOOSO "TX> S-l. By: ALI SADRE Wc. coKPuw^rr ^wftu^iMu rm^^ pev^ Eni/osuris:'' EsGil Corporation • GA • EJ • PC 12/19 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858)560-1468 • Fax (858) 560 MORE INFORMATION REGARDING PLANNED INDUSTRIAL PERMIT AMENDMEi PERCENTAGES SHOWING HOW THE CARPORTS FALL BELOW THE THRESHOi FOR A PERMIT AMENDMENT. SEE ADDITIONAL COMMENTS FOR MOI INFORMATION. Policy 44 - Neighborhood Architectural Design Guidelines SDD 1. ApplicabHity: YES • NO g| El • • 2. Project complies: YESD NOD la O • Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear Top of slope: Required. Required. Required. Required. Required. 2. Accessory structure setbacks: Shown. Shown. Shown. Shown. Shown. Front Interior Side: Street Side: Rear Structure separation: Required §Q; Shown 50'+ Required Jg Shown 10'-» Required SJI Shown §fi;+ Required ggr Shown 20'+ Required N/A Shown N/A 3. Lot Coverage: 4. Height: 5. Parking: Reouired N/A Shown £^ Required Shown. Spaces Required. Shown (breakdown by uses for comnnercial and industrial projects required) Resklential Guest Spaces Required Shown Additional Comments #1. PLEASE SHOW ON THE PLANS HOW THE PROJECT MKT THE REQUIREMENTS OF SECTION 21.34.110 fA) t1^l REGARDINO AMENDMENTS T THE PLANNED INDUSTRIAL PERMIT. A TABLE SHOWING THE APPUCABL PERCENTAGES NEED TO BE SUBMITTED AND STATED ON THE PLANS. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER _ IS TO-TTftu 0 0 2. WHitu \i UiEfS BuOfc ftlBTS*' _ DATE -fMOM op Twff |tB:^u.vn.©>o ««P. NOTtETi f mis um iliium mn mm 60026 VO 'GVaSldVO AVM>lbVd VdVlAV OOOL 1N3W30VNVW WSV/WO/W 3anionais lyodavo od c (O t Ico ZI./6/I. - nvmnans ONZ il hi It I I 11 3 iiSI i I 1 f i I ill 11 ifi lil mi iiii ffi li II I IS S 3 I ! 11lli i I Ilil I i II il II it If n. m $ , pi lis 11 IIIIIIII , - «, ^ i llilllllll^^ll li m I i is nil s ! s ii ill! i p Mi fill fits-a ?|! I ^ i « ll Si 1^ ?p 2 5 . Q. ¥ Bli Pl i ^ CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for CB 11-2651 Date: December 28, 2011 Project Address: 1000 AVIARA PARKWAY APN: 212-040-70-00 Project Description: CONSTRUCT CARPORTS FOR NINE SPACES Valuation: $20,503.00 ENGINEERING Contact: Linda Ontiveros Phone; 760-602-2773 Email: linda.ontiveros@carlsbadca.gov Fax: 760-602-1052 n RESIDENTIAL [Zl TENANT IMPROVEMENT • RESIDENTIAL ADDITION MINOR (<$20,000.00) • CARLSBAD COMPANY STORES PLAZA CAMINO REAL COMPLETE OFFICE BUILDING m OTHER: NO FEES DUE OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT DATE: Notification of Engineering APPROVAL has been sent to via 0" E-36 1 of 1 REV 4/30/11 ^ STORMWATER „ , , . «% STANDARDS "^"I^^^Z^^ ^ CITY OF QUESTIONNAIRE leaS Faraday Avenue r^ARI ^RAr^ E-34 760-602-2750 \i,i«>/%l\l»%^D/ll«/ C'O** www.carlsbadca.gov INSTRUCTIONS: To address post-development pollutants that may be generated from development projects, the City requires that new development and significant redevelopment priority projects incorporate Permanent Storm Water Best Management Practices (BMP's) into the project design per the City's Standard Urban Stormwater Management Plan (SUSMP). Initially this questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision, discretionary permits and/or construction permits). The results of the questionnaire determine the level of storm water standards that must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to 'Standard Stormwater Requirements' or be subject additional criteria called 'Priority Development Project Requirements'. Many aspects of project site design are dependent upon the storm water standards applied to a project. Applicant responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has responsibility for making the final assessment after submission of the development application. If staff determines that the questionnaire was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by the applicant, this will result in the return of the development application as incomplete. In this case, please make the changes to the questionnaire and resubmit to the City. if applicants are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, they are advised to seek assistance from Land Development Engineering staff. A separate completed and signed questionnaire must be submitted for each new development application submission. Only one completed and signed questionnaire is required when multiple development applications for the same project are submitted concun-ently. in addition to this questionnaire, applicants for construction permits must also complete, sign and submit a Project Threat Assessment Form to address construction aspects of the project. Please answer the questions below, follow the instructions and sign the form at the end. 1. Is your project a significant redevelopment? DEFINITION: Significant redevelopment is defined as the creation, addition or replacen^ient of at least 5,000 square feet of impervious surface on an already existing developed site. Significant redevelopment includes, but is not limited to: the expansion of a building footprint; addition to or replacement of a structure; structural development including an increase in gross floor area and/or exterior construction remodeling; replacement of an impervious surface that is not part of a routine maintenance activity; and land disturbing activities related with structural or impervious surfaces. Replacement of impervious surfaces includes any activity that is not part of a routine maintenance activity where impervious material(s) are removed, exposing underlying soil during construction. If your project IS considered significant redevelopment, then please skip Section 1 and proceed with Section 2. If your project IS NOT considered significant redevelopment, then please proceed to Section 1. E-34 Pagel of3 REV3/23/10 ^ CITY CARLSBAD O F STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Engineering Department 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov SECTION 1 NEW DEVELOPMENT PRIORITY PROJECT TYPE Does you project meet one or more of the following criteria: YES NO 1. Housina subdMsions of 10 or more dwellina units. Examoles: sinale familv homes, multi-familv homes, condominium and apartments 1^ 2. Commercial - areater than 1-acre. Anv develooment other than heaw industrv or residential. Examoles: hosoitals: laboratories and other medical facilities; educational institutions; recreational facilities; municipal facilities; commercial nurseries; multi-apartment buildings; car wash facilities; mini-malls and other business complexes; shopping mails; hotels; office buildings; public warehouses; automotive dealerships; airfields; and other light industrial facilities. 3. Heaw Industrial 1 Industrv- areater than 1 acre. Examoles: manufacturina olants. food orocessino olants. metal working facilities, printing plants, and fleet storage areas (bus, truck, etc.). 4. Automotive reoair shoo. A facilitv cateaorized in anv one of Standard Industrial Classification (S\C) codes 5013. 5014, 5541, 7532-7534, and 7536-7539 5. Restaurants. Anv facilitv that sells oreoared foods and drinks for consumotion. Inciudina stationarv lunch counters and refreshment stands selling prepared foods and drinks for immediate consumption (SIC code 5812), where the land area for development is greater than 5,000 square feet. Restaurants where land development is less than 5,000 square feet shall meet all SUSMP requirements except for structural treatment BMP and numeric sizing criteria requirements and hydromodification requirements. 6. Hillside develooment. Anv develooment that creates 5.000 sauare feet of imoervious surface and is located in an area with known erosive soil conditions, where the development will grade on any natural slope that is twenty-five percent (25%) or greater. 7. Environmentallv Sensitive Area (ESA)\ All develooment located within or directiv adiacent^ to or discharaina directly^ to an ESA (where discharges from the development or redevelopment will enter receiving waters within the ESA), which either creates 2,500 square feet of impervious surface on a proposed project site or increases the area of imperviousness of a proposed project site to 10% or more of its naturally occurring condition. 8. Parkina lot. Area of 5.000 sauare feet or more, or with 15 or more oarkina soaces. and ootentialiv exoosed to urban runoff 9. Streets, roads, hiahwavs. and freewavs. Anv oaved surface that is 5.000 sauare feet or areater used for the transportation of automobiles, trucks, motorcycles, and other vehicles 10. Retail Gasoline Outlets. Servlna more than 100 vehicles oer dav and areater than 5.000 sauare feet 11. Coastal Develooment Zone. Ar^'v oroiect located within 200 feet of the Pacific Ocean and (1) creates more than 2500 square feet of impermeable surface or (2) increases impermeable surface on property by more than 10%. 12. More than 1-acre of disturbance. Proiect results in the disturbance of more than 1-acre or more of land and is considered a Pollutant-generating Development Project*. y 1 Environmentally Sensitive Areas include but are not limited to all Clean Water Act Section 303(d) Impaired water bodies; areas designated as Areas of Special Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); water bodies designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Dlego Basin (1994) and amendments); areas designated as preserves or their equivalent under the Multi Species Conservation Program within the Cities and County of San Diego; and any other equivalent environmentally sensitive areas which have been identified by the Copermittees. 2 "Directly adjacenf means situated within 200 feet of the Environmentally Sensitive Area. 3 "Discharging directly to' means outflow from a drainage conveyance system that is composed entirely of flows from the subject development or redevelopment site, and not commingled with flow from adjacent lands. 4 Pollutant-generating Development Projects are those projects that generate pollutants at levels greater than bacl^ground levels. In general, these include all projects that contribute to an exceedance to an Impaired water body or which create new impervious surfaces greater than 5000 square feet and/or Introduce new landscaping areas that require routine use of fertilizers and pesticides. In most cases linear pathway projects that are for infrequent vehicle use, such as emergency or maintenance access, or for pedestrian or bicycle use, are not considered Pollutant-generating Development Projects if they are built with pervious surfaces or if they sheet flow to sun'ounding pervious surfaces. Section 1 Results: .If you answered YES to ANY of the questions above your project Is subject to Priority Development Project requirements. Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3. A Storm Water Management Plan, prepared in accordance with City Storm Water Standards, must be submitted at time of application. If you answered NO to ALL of the questions above, then your project is subject to Standarcl Stormwater Requirements. Please check the "does not meet PDP requirements" box in Section 3. E-34 Page 2 of 3 REV 3/23/10 CITY OF CARLSBAD STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Engineering Department 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov SECTION 2 SIGNIFICANT REDEVELOPMENT Complete the questions below regarding your redevelopment project: YES NO 1. Project results in the disturbance of more than 1 -acre or more of land and is considered a Pollutant-generating Development Project (see definition in Section 1). If you answered NO, please proceed to question 2. If you answered YES, then you ARE a significant redevelopment and you ARE subject to PRIORITY DEVELOPMENT PROJECT requirements. Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 below. 2. Is the project redeveloping an existing priority project type? (Priority projects are defined in Section 1) If you answered YES, please proceed to question 3. If you answered NO, then you ARE NOT a significant redevelopment and your project is subject to STANDARD STORMWATER REQUIREMENTS. Please check the "does not meet PDP requirements" box in Section 3 below. 3. Is the project solelv limited to just one of the following: a. Trenching and resurfacing associated with utility work? b. Resurfacing and reconfiguring existing surface parking lots? c. New sidewalk construction, pedestrian ramps, or bike lane on public and/or private existing roads? d. Replacement of existing damaged pavement? If you answered NO to ALL of the questions, then proceed to question 4. If you answered YES to ANY of the questions then you ARE NOT a significant redevelopment and your project is subject to Standard Stormwater Requirements. Please check the "does not meet PDP requirements" box in Section 3 below. 4. Will your redevelopment project aeate, replace, or add at least 5,000 square feet of impervious surfaces on an existing development or, be located within 200 feet of the Pacific Ocean and (1)create more than 2500 square feet of impermeable surface or (2) increases impermeable surface on the property by more than 10%? If you answered YES, you ARE a significant redevelopment, and you ARE subject to PRIORITY DEVELOPMENT PROJECT requirements. Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 below. If you answered NO, then you ARE NOT a significant redevelopment and your project is subject to STANDARD STORMWATER REQUIREMENTS. Please check the "does not meet PDP requirements" box in Section 3 below. SECTION 3 Questionnaire Results: • My project meets PRIORITY DEVELOPMENT PROJECT (PDP) requirements and must comply with additional stormwater criteria per the SUSMP and must prepare a Storm Water Management Plan for submittal at time of application. My project does not meet PDP requirements and must only comply with STANDARD STORMWATER REQUIREMENTS per the SUSMP. Applicant Information and Signature Box This Box for City Use Only Address: /OOO AviOJtL Pbjo^ Assessor's Parcel Number(s): Applicant Name: looo M\eur«^ PiCu/^ Applicant Title: Applicant Signature: Date:^ *^ « i2-»S-l/ E-34 Page 3 of 3 REV 3/23/10 CITY OF CARLSBAD STORM WATER COMPLIANCE ASSESSMENT B-24 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov I am applying to the City of Carlsbad for the following type{s) of construction permit: ^^^^^JC^Building Permit • Right-of-Way Permit • My project is categorically EXEMPT from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the following permit types: Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Patio/Deck Photovoltaic Re-Roofing Sign Spa-Factory Sprinkler Water Discharge Project Storm Water Threat Assessment Criteria* No Threat Assessment Criteria f^^'s.Sr projecf qualifies as NO THREAT and is exempt from the requirement to prepare a stonn water pollution prevention plan (SWPPP) because ^^sit meets tiie "no threaf assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Constnjction SWPPP Tier ^/ Ceyel. I^y project does not meet any of the High, Moderate or Low Threat criteria described below. Tierl - Low Threat Assessment Criteria • My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more of the following criteria: • Results In some soil disturbance; and/or • Includes outdoor constmction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling). Tier 2 - Moderate Threat Assessment Criteria • My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria: • Project requires a grading plan pursuantto the Carlsbad Grading Ordinance (Chapter 15.16 ofthe Carisbad Municipal Code); or, • Project will result in 2,500 square feet or more of soils disturbance including any associated constaiction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria: • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area Is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturbed area is located along or within 30 feet of a storm drain inlet an open drainage channel or watercourse, and/or • Constnjction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). Tiers - Signifcant Threat Assessment Criteria • My project Includes clearing, grading or other disturbances to the ground resulting In soil disturbance totaling one or more acres Including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or • My project Is part of a phased development plan that will cumulatively result In soil disturbance totaling one or more acres Including any associated construction staging, equipment storage, refueling and maintenance areas: or, • My project is located Inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to neartiy receiving waters by way of stonn water mnoff or non-storm water discharge(s). / cerli'iy to the best of my knowledge that the above checked statements are true and correct I understand and acknowledge that even though this project does not require preparation ofa construction SWPP, I must still adhere to, and at all times during construction activities for the permit type(s) check above comply with the storm water best management practices pursuant to Titie 15 of tiie Carlsbad Municipal Code and to City Standards. "The City Engineer may authorize minor variances from the Storm Water Threat /Assessment Criteria in special circumstances where it can be shown that a lesser or higher Constmction SWPPP Tier Level is warranted. Project Address: Assessor Parcel No. Owner/Owner's Authorized Agent Name: t\jGC4;l-d... • J^oaiM franco - OmmitJiid TiHe: Owner/Owner's Authorized Agent Signature: Date: l-z -IS'// Cnf Concurrence: /I By: \iaft\i B-24 Page 1'of 1 Rev.03/09 ^ PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division V c.TY OF REVIEW CHECKLIST TeTeolTeil CARLSBAD P-28 www.carlsbadca.gov Plan Check No. CB112651 Address 1000 AVIARA PKWY DateJmfr2r Review #^^ Planner GINA RUIZ Ptione (760) 602- 4675 ijoMf 10^ APN: 212-040-70-00 Type of Project & Use: CARPORT Net Project Density: DU/AC Zoning: P-M-Q/OS General Plan: PI/OS Facilities Management Zone: 5 CFD (in/out) # 1 Date of Darticipation:05/07/1991 Remaining net dev acres: (For non-residential development: Type of land use created by tiiis permit: ) REVIEW #: ^ 12 3 Leqend: ^ Item Complete ( Gjltem Incomplete - Needs your action IS • • Environmental Review Required:^ YES • NO IEI TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: 13 • • Discretionary Action Required: YES • NO |E1 TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: • • Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO • CA Coastal Commission Authority? YES • NO M If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): EXEMPT PER 21.201.060 (A) (2) • • Habitat IVIanagement Plan Data Entry Completed? YES • NO |E! If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) • • Inclusionary Housing Fee required: YES • NO |3 (Effective date of Inclusionary Housing Ordinance - May 21,1993.) Data Entry Completed? YES • NO • (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) • • Housing Tracking Form (form P-20) completed: YES • NO • N/A|E1 p-28 Page 1 of 2 07/11 MORE INFORIVIATION REGARDING PLANNED INDUSTRIAL PERMIT AMENDMENT PERCENTAGES SHOWING HOW THE CARPORTS FALL BELOW THE THRESHOLD FOR A PERMIT AMENDMENT. SEE ADDITIONAL COMMENTS FOR MORE INFORMATION. Policy 44 - Neighborhood Architectural Design Guidelines • • 1. Applicability: YES • NO IE! • • 2. Project complies: YES • NOO Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required, Required, Required. Required, Required. Shown Shown Shown Shown Shown • • 2. Accessory structure setbacks: Front: Interior Side: Street Side: Rear: Structure separation: Required 501 Shown 50'+ Required 101 Shown 10'+ Required 501 Shown 50'+ Required 201 Shown 20'+ Required N/A Shown N/A • • 3. Lot Coverage: Required N/A Shown N/A • • 4. Height: Required Shown • • 3)X 5. Parking: Spaces Required Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments #1. PLEASE SHOW ON THE PLANS HOW THE PROJECT MEETS THE REQUIREMENTS OF SECTION 21.34.110 (A) (1-6) REGARDING AMENDMENTS TO THE PLANNED INDUSTRIAL PERMIT. A TABLE SHOWING THE APPLICABLE PERCENTAGES NEED TO BE SUBMITTED AND STATED ON THE PLANS. PLANCHECK #2: SAME COMMENTS FROM PLANCHECK #1 ABOVE OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER-^^DATE f^-f/i IX^ Carlsbad Fire Department BLDG. mPT COPY Plan Review Requirements Category: TI, COMM Date of Report: 01-25-2012 Reviewed by: Name: FIANCO JOANNE Address: STE 220 1000 AVIARA PARKWAY CARLSBAD CA 92011 Permit #: CBl 12651 Job Name: AVIARA HOLDINGS-CONSTRUCT Job Address: 1000 AVL\RA PY CBAD INCOMPLETE—The item you have submitted for review is inoompletei At this timepdus office camnot adequately oonduot a review to determine oomplionoo with the applioable oodoo ond/or otandcirdo. Pleooo review- oarofuUy all comments attached. Ploaso resubmit tho neooooary piano ond/or opeoifieations, with changes "cloudeA", •to this office for review and approval. • Conditions: Cond: CON0005166 [MET] APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDINGPERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 01/25/2012 By: df Action: AP BLDG. DEPT COPY RECOMMENDATION FOR APPROVAL Page: 1 ofl Daryl K, James & Associates, Inc. Checked by: Matthew Ernau Date: 1/18/2012 APPLICANT: Joanne France JURISDICTION: Carlsbad Fire Department PROJECT NAME: Carport PROJECT ADDRESS: 1000 Aviara Parkway PROJECT DESCRIPTION: CBl 12651 INSTRUCTIONS • This plan review has been conducted in order to verify conformance to minimunri requirements of codes adopted by the Carlsbad Fire Department. • The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. S-1 Provide a site plan showing 24 ft min clear fire access width. Make sure when measuring that you measure from the end of the carport unless you have the required vertical clearance. OK Provide a side view that shows if they is any type of overhang min vertical clearance is 13.5 ft. If you are using part of the overhang for your 24 ft fire access. If not state on plan. OK Provide three fire department comments on sheet S-1 OK 1) Fire apparatus roads shall have an unobstructed width of not less than 24 feet. 2) Fire apparatus roads shall have an unobstructed vertical clearance of 13.5 feet. 3) If you are not using the overhang as part of your 24 ft fire access state on plan. t RECOMMENDATION FOR APPROVAL Page: 1 ofl Daryl K. James & Associates, Inc. Checked by: Matthew Ernau Date: 1/18/2012 APPLICANT: Joanne France JURISDICTION: Carlsbad Fire Department PROJECT NAME: Carport PROJECT ADDRESS: 1000 Aviara Parkway PROJECT DESCRIPTION: CBl 12651 INSTRUCTIONS • This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carisbad Fire Department. • The items below require con-ection, clarification or additional information before this plan check can be approved for permit issuance. S-1 Provide a site plan showing 24 ft min clear fire access width. Make sure when measuring that you measure from the end of the carport unless you have the required vertical clearance. OK Provide a side view that shows if they is any type of overhang min vertical clearance is 13.5 ft. If you are using part of the overiiang for your 24 ft fire access. If not state on plan. OK Provide three fire department comments on sheet S-1 OK 1) Fire apparatus roads shali have an unobstructed width of not less than 24 feet. 2) Fire apparatus roads shall have an unobstructed vertical clearance of 13.5 feet. 3) If you are not using the overhang as part of your 24 ft fire access state on plan. BLDG. DEPT COPY CORRECTION LIST Page: 1 ofl Daryl K. James & Associates, Inc. Checked by: Matthew Ernau Date: 12/28/2011 T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Joanne France JURISDICTION: Carisbad Fire Department PROJECT NAME: Carport PROJECT ADDRESS: 1000 Aviara Parkway PROJECT DESCRIPTION: CB112651 INSTRUCTIONS • This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carisbad Fire Department. • The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. " To expedite the recheck process, please note on this list (or copy) how and where each correction item has been addressed, i.e. sheet number, note number, detail number, legend number, etc Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates.. • Piease direct aniy questions regarding this review to: Matthew Ernau 760-738-8279 or ernau57@cox.net • CORRECTED PLANS, DESCRIPTIVE NARRATIVE OF REVISIONS FOLLOWING EACH COMMENT ON THiS FORM, AND A COPY OF BUILDiNG DEPARTMENT (EsGil) COMMENTS MUST BE SUBMITTED DIRECTLY TO: " Matthew Ernau 1382 Hale Ave Escondido, CA 92029 IF PLANS WITH CORRECTIONS ARE NOT DELIVERED DIRECTLY TO THE ADDRESS ABOVE, RECOMMENDATION FOR APPROVAL COULD BE DELAYED. S-1 Provide a site plan showing 24 ft min clear fire access width. Make sure when measuring that you measure from the end of the carport unless you have the required vertical clearance. Provide a side view that shows if they is any type of overhang min vertical clearance is 13.5 ft. If you are using part of the overhang for your 24 ft fire access. If not state on plan. Provide three fire department comments on sheet S-1 1) Fire apparatus roads shall have an unobstructed width of not less than 24 feet. 2) Fire apparatus roads shall have an unobstructed vertical clearance of 13.5 feet. 3) If you are not using the overhang as part of your 24 ft fire access state on plan. Baja Construction Co., Inc. 223 Foster Street Martinez, CA 94553 (800) 336-9600 Page I of Job #9791 Full Cantilever (FC) Structure #9791 WCM/ASM Management 1000 Aviara Parkwav Parkwav. Carlsbad. Ca. 92011 / WCM/ASM Management Design Criteria (2010 CBO: Occupancy Categoiy II Use: Altemative Basic Load Combinations (Section 1605.3.2) Roof Live Load RLL := 20.0psf Basic Wind Speed (mph) 85 mph Wind Expos uie C ASD Wmd Factor © := 1.3 Importance Factor I := l .0 Seismic design categoiy D Site class D Importance Factor I:= l.o 12-13-11 Allowable Stresses Sheeting ASTM A792 Gi-ade 80 Fy:= 80 ksi Frames, purlins ASTM A653 Grade 55 Fy:= 55.0 ksi Allowable Soil Bearing Pressure SBPaiio^:= 1500 psf Allowable Lateral Bearing Pressure S^:= 150-pcf Concrete f c := 2500 psi at 28 days Reinforcements ASTMA615, Grade 40 (min.) Roof Dead Loads: Sheeting RDLl := l.O psf Fb := 36.0 ksi Fb := 33.0-ksi Framing RDL2 Misc RDL3:= l.Opsf = 2.00psf Total Roof Dead Load, RDL := RDLl + RDL2 + RDL3 MECAWind Version 2.0.3.0 per ASCE 7-05 Developed by MECA Enterprises, Inc. Copyright 2011 www.mecaenterprises. com Date : 12/12/2011 Project No. Company Name : Designed By Address : Description City : Customer Name State : Proj Location File Location: C:\Users\danilo\Documents\CALCS & DWG TEMPLATES\BOXED FC & TEE\FC full cantilever\9791-FC-SSS WCM\#9791 MECft.vmd Detailed Basic Wind Speed(V) Stmctural Category- Natural Freguency Importance Factor Alpha At Am Cc Epsilon Slope of Roof L: Roof Hor. Width ft Ht: Mean Roof Ht Wind Load Design(Method 2) per ASCE 7-05 = 0 85.00 mph II N/A 1.00 9.50 0.11 0.15 0.20 0.20 629 12 18.00 ft 12.00 ft Structure Type Exposure Category Flexible Structure Kd Directional Factor Zg Bt Bm 1 Zmin Slope of Roof(Theta) = Building C No 0. 85 = 900.00 ft 1. 00 0.65 = 500.00 ft 15.00 ft 3.00 Deg D: Roof Length along Ridge= 89.00 Type of Roof = Monoslope Gust Factor Category X Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6*Ht Izm: Cc*(33/Zm)^0.167 Lzm: 1*(Zm/33)^Epsilon Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) 0.85 15.00 ft 0.23 427.06 ft 0.89 0.87 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 0.85 Figure 6-5 Internal Pressure CoeEficients for Buildings, GCpi GCPi : Internal Pressure Coefficient = +/-0 Figure 6-18A Open Building-Monoslope Roof 1111 n 1111111 Gamma = 0 degrees. Clear Wind Flow Load Cnw Cnl Windward Wind Pres. Leeward Wind Pres. Case psf psf A B 1.200 -1.100 0.300 -0.100 13.613 3.403 -12.478 -1.134 Load Case Cnw Gamma = 180 Cnl degrees. Clear Wind Flow windward Wind Pres. Leeward Wind Pres. psf psf A B 1.200 -1.100 0 .300 -0.100 13.613 3.403 -12.478 -1.134 Notes: 1) Cnw- Net Pressures (contributions from top and bottom surfaces for windward roof surfaces. Notes: 2) Cnl- Net Pressures (contributions from top and bottom surfaces) for leeward roof surfaces. Gamma = 90 degrees. Clear Wind Flow Length Along Roof Angle Load Cn Wind Pressure Along Ridge Ridge of Roof (Theta) Case psf psf <= 12.0 Theta<=45 deg >12.0&<=2*12.0 Theta<=45 deg >2*12 Theta<=45 deg A B A B A B 0.800 0.800 0.600 0 .500 0.300 0.300 -9.075 9.075 -6.806 5.672 -3 .403 3 .403 Notes: 1) Cn- Net Pressures (contributions from top and bottom surfaces). Notes: 2) Plus and minus signs signify pressures acting towards and away from the top roof surface, respectively. MECAWind Version 2.0.3.0 ASCE 7-05 Developed by MBCA Enterprises, Inc. Copyright 2011 www.mecaenterprises.com Date : 12/12/2011 Project No. Company Name : Designed By Address : Description City : Customer Name State : Proj Location File Location: C:\Users\danilo\Documents\CALCS & DWG TEMPLATES\BOXED FC & TEE\FC full cantilever \9791-FC-SSS WCM\#9791 MECA.vmd 3 a Monoslope Roof T 111 i 11 i 111111 wind Pressure on Components and Cladding width of Pressure Coefficient Zone Description Width Span Area Zone Cn "a" Cn 3 ft Max P Min P ft ft ft^2 Max Min psf psf Zone 1 1 00 1 00 1 00 1 1 360 -1. 220 15.428 -13. 840 Zone 2 1 00 1 00 1 00 2 2 040 -1. 860 23.142 -21. 100 Zone 3 1 00 1 00 1 00 3 2 720 -3 . 660 30.856 -41. 519 Zone 1 Sheat'ng 3 00 7 50 22 50 1 1 360 -1. 220 15.428 -13. 840 Zone 2 Sheat'ng 3 00 7 50 22 50 2 2 040 -1. 860 23.142 -21. 100 Zone 3 Sheat'ng 3 00 7 50 22 50 3 2 040 -1. 860 23.142 -21. 100 Zone 1 purlins 7 50 18 00 135 00 1 1 360 -1. 220 15.428 -13. 840 Zone 2 purlins 7 50 18 00 135 00 2 1 360 -1. 220 15.428 -13. 840 Zone 3 purlins 7 50 18 00 135 00 3 1 360 -1. 220 15.428 -13. 840 Khcc:Comp. & Clad. Table 6-3 Case 1 Qhcc:.00256*V*2*I*Khcc*Kht*Kd 0.85 = 13.35 psf Conterminous 48 States 2005 ASCE 7 Standard Latitude = 33.123854 Longitude = -117.301539 Spectral Response Accelerations Ss and SI Ss and SI = Mapped Spectral Acceleration Values Site Class 8 - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.01 deg grid spacing Period Sa (sec) (g) 0.2 1.221 (Ss, Site Class B) 1.0 0.461 (SI, Site Class B) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 33.123854 Longitude = -117.301539 Spectral Response Accelerations SMs and SMI SMs = Fa X Ss and SMI = Fv x SI Site Class D - Fa = 1.011 ,Fv = 1.539 Period Sa (sec) (g) 0.2 1.235 (SMs, Site Class D) 1.0 0.710 (SMI, Site Class D) Conterminous 48 States 2005 ASCE 7 Standard Latitude = 33.123854 Longitude = -117.301539 Design Spectral Response Accelerations SDs and SDI SDs = 2/3 X SMs and SDI = 2/3 x SMI Site Class D - Fa = 1.011 ,Fv = 1.539 Period Sa (sec) (g) 0.2 0.823 (SDs, Site Class D) 1.0 0.473 (SDI, Site Class D) Baja Construction Co., Inc. 223 Foster Street Martinez, CA 94553 (800) 366-9600 Pagee Seismic Forces: 2009 IBC, 2010 CBC & ASCE 7-05 Input: Period "T" Determination: h = 12.000 ft (height in ft. to top of structure) T = Ta Sec 12.8.2 R= 1.500 Table 12.2-1 1= 1.000 Sed 1.5.1 Ta = Ct*h'"„ Eq(12.8-7) Ss= 1.221 from USGS 81 = 0.461 from USGS Ct = 0.02 Table 12.8-2 Fa= 1,011 Table 11.4-1 x= 0.75 Table 12.8-2 Fv= 1.539 Table 11.4-2 Ta = T= 0.128948 TL= 4 Table 22-15 (worst case) Equivalent Lateral Force Procedure: Sec 12.8 V = Cs*W Cs = Sds/(R/I) Eq(12.8-2) Sds = (2/3)*Fa*Ss = 0.822954 Cs=; 0.5486 but need not exceed: Cs= Sd1/(r(R/l)) where T<TL Eq(12.8-3) Sdi = (2/3)*Fv*S1 = 0.472986 Cs = I 2.4454 but shall not be less than: Cs = i 0.01 and where 81 > 0.6g Cs shall not be less than: Cs = 0.5*S1/(R/I) Cs= ; 0.1537i Eq(12.8-5) Eq(12.8-6) V = 0.5486 W Baja Construction Co., Inc. 223 Foster Street Martinez, CA 94553 (800) 366-9600 Page? Job #9791 Roof Sheeting: 29ga AEP "Alta Rib" X-span Panels L := 7.50 ft cantilever, a := 2.0 ft tributaiy, s := l.O-ft w := (RLL + RDLl)(s) w = 21.00plf Sneg:= 0.085 lin^ Spos:= 0.1046-in Cantilever: Meant := 0.5wa^ Meant = 42.00 ft-Ibf -(4a^-L-L^ + 3a^) Imin:= 0.1117-in Meant ft), Acant: wa 'cant „ Sneg Acant = -0.26 in 24-E-Imin Center Span: x:= 0.5 L- ^ 2^ 1-^ T2 Mx:= —-(L + a)^ (L - a)^ fbctr:= 8L max(Mx, Meant) Ax:= Spos x= 3.48 ft (fromRl) Mx= 127.40 ft-Ibf fljctr = 14.62ksi E := 29500-ksi fbcant = 5.92 ksi 2-a = -188.23 Acant w-x 24-E-Imin-L Allowable deflection limit = L/60 ~ O.K. Iiiliilil irm Rl R2 •{h^ - 2-\}+ L-x^ - 2-a^-L^ + 2-a^-x^) Ax = 0.38 in = 239.53 Ax Uplift: Pu = 21.10psf Wupiift- (co-Pu - RDLl)-(s) at cant.: Meant := 0.5-(wupiift)-a^ Wuplift 2x2 Mx := (L + a) -(L - a) 8-L^ CO := 1.3 Wupiift = 26.43 plf Meant = 52.86ft-lbf Mx= 160.35 ft-lbf Meant „ . . fb := fb = 4.56 ksi fb'. 1.33-Spos Mx 1.33Sneg fb = 17.00 ksi Baja Construction Co., inc. 223 Foster Street Martinez, CA 94553 (800) 366-9600 Pages Job #9791 Roof Purlins: Cee 8" x 3 1/2" x 16ga L := 18.0-ft cantilever, a := 9.0 ft tributaiy, s := 3.33-ft w := (RDL + RLL) • (s) w = 79.92 plf Purlin Pressures (zone 3): p3prln.pos= 15.428 psf P3prln.neg= 13.840 psf Sx := 2.035-in^ w, pos •= (<B-p3prln.pos + RDL)-(S) Wneg := (co p3prln.pos " 0.67 RDL)-(S) Ix := 9.7024in'' M := 0.125-max(w,0.75-Wpos,0.75-Wneg)-L^ „ M Ax:= 5-w-L^ 384-E-Ix Ax = 0.66 in E := 29500-ksi M = 3.24 ft-kips fljctr = 19.09 ksi — = 327.51 Ax Wpos = 80.11 plf w„eg = 57.86 plf Allowable live load deflection limit (Table 1604.3, Footnote a) = L/l50 ~ O.K. At Cantilever: Meant := 0.5-max(w,0.75-Wpos,0.75-Wneg)-a^ Meant fb, 'cant • Sx Acant := ^'^ •(4-a^-L - L^ -f 3-a^) 24-E-Ix Acant = 0.40 in Meant = 3236.76 ft-lbf fbcant = 19.09 ksi 2 a = 545.85 Acant Baja Construction Co., Inc. 223 Foster Street Martinez, CA 94553 (800) 366-9600 Page 9 Job #9791 Purlin to Beam Connection: 14ga cKp with (4) #12 screws each connection Purlins are stacked on top of beams. Check connection for uplift load. Purlin to Clip Connection: d := 0.216 in Q := 3.0 Steel in contact with screw head (14ga clip) Fui := 65-ksi tj := 0.070-in Pn, := 2.7-ti-d-Fuj Pnj = 2.65 kips Steel not in contact witli screw head (14ga purlin) Fu2 := 65-ksi Pn2 := 2.7-t2-d-Fu2 For to /1} equal to or less than 1 \0.5 Pn, := 4.2. •Fui Pn3 = 2.35 kips Allow Shear per screw ft Pn := if — < 1 ,min(Pni,Pn2,Pn3),min(Pni,Pn2) Pn = 2.35 kips => Pa:= — Q Pn = 2.35 kips Pa = 0.783 kips Purlin Reaction: Maximum span, L := 18.0-ft Ry := 0.5-Wneg-(L) Ry = 0.52 kips for(2)#12 screws: 2-(1.33-Pa) = 2.08kips ~ O.K. Purlin Reaction at Cantilever Support: cantilever span, a = 9.00 ft backspan, L := 18.0-ft .2 Rcant := 0.5 (w)-(L + a)^ Rcant = 1.62 kips O.K. for (4) #12 screws: 4-(1.33-Pa) = 4.17kips ~ O.K. Clip to Beam Connection: Clips are welded to beam ~ adequate by inspection t2 := 0.070-in Pn2 = 2.65 kips Baja Construction Co., Inc. 223 Foster Street Martinez, CA 94553 (800) 366-9600 Page 10 Job #9791 Roof Beams: (2) Cee 16" x 4.0" x 12ga boxed Tributaiywidth, s^wfrs 18.0-ft (bay trib) tributaiy depth, d^wfrs := 18.00-ft Tributaiy Area: At:= (s„wfrs) (dmwfrs) At = 324.00 ft^ Rl := if f At<200-ft ,l,if r At > 600-ft ,0.60,1.2 - 0.001 ft JJ Rl = 0.876 Roof slope (inch perfoot), F := 2.115 R2 := if(F < 4,1 ,if(F > 12,0.6,1.2 - .05F)) R2 = 1.00 Lr := (R1)-(R2)(RLL) Lr = 17.52psf wdl = 72.00 plf wll = 315.36 plf w = 387.36 plf wdl := (RDL)-(s„^„) wll := (Lr)-(smwfrs) w := wdl + wll Beam Pressures (mwfrs): ASD wind factor, co = 1.30 Pfrm^^,ind= 13.613 psf Pfrmjee = 3.403 psf Wwind:= (<0-Pfi'mwind)-(smwfrs) Wiee := ((B-Pfrmiee)-(sniwfrs) Wwind = 318-54plf Wiee = 79.63 plf ~ Dead + Live Load controls Ll := 2.40-ft L2:= 15.67-ft Mmax := 0.5(w)-(L2) Sx:= 18.6758 in^ . 4 Mmax = 47.56 ft-kips Ix := 190.9277-in E := 29500-ksi fl3:= A := Mmax Sx w-L2'^ 8-E-Ix flj = 30.56ksi A =0.90 in 2-(L2) = 419.88 Beam is adequate. Baja Construction Co., Inc. Page 11 223 Foster Street Job #9791 Martinez, CA 94553 (800) 366-9600 Beam to Column Connection: Column/Beam depth, D:= 16.0-in Vweld := Mmax - 0.5-(wdl) Ll^ Vweld = 47.35ftkips Beam bottom flange to column web: Flare-Bevel Groove Weld - Transverse Loading: tensile strength, Fu := 65.0-ksi least member thickness, t := 0.105- in factor of safety, Q := 2.55 Pn := 0.833-t-Fu Pn = 5.69 — in ^ Pn « .,0 kips Pa := — Pa = 2.23 —^ Q in Weld moment capacity(one side), Mlweld := 0.5-Pa-D^ Mlweld = 23.78ftkips Weld capacity both sides, 2-Mlweld = 47.56 ft-kips 1/4" End plate vertical weld to beam and column: Fillet Weld - Longitudinal Loading: length of weld (minimum at column), L:=8.00-in -^=76.19 factor of safety, Q := 3.05 Pn := if] ^ < 25,f 1 - -—-^ | t L-Fu,0.75-t-L Fu t Pn = 40.95 kips Pn Paiongit := — Paiongit = 13.43kips M2weld ;= Pa,o„gif(D) M2weld = 17.90 ft-kips Weld capacity both sides, 2-M2weld = 35.80ft-kips Total weld capacity, (2-Mlweld-f 2-M2weld) = 83.37ft-kips - O.K. additional weld at bottom of 1/4 end plate : Baja Construction Co., Inc. 223 Foster Street Martinez, CA 94553 (800) 366-9600 Page 12 Job #9791 Column Loading: Design height, Hcol := 9.00 ft Beam sloped length, Lt := 15.67-ft Roof slope, (]) ;= 3.0deg DL on column, wdl = 72.00plf Pdl := wdl-(d„^„) LL on column, wll = 315.36 plf Pll := (wll)-(d„^,3) DLH-LL Moment to column from roof beam: Lt = 15.67ft MDL := 0.5-wdl-(Lt^) MDL = 8.840ft-kips x2 Tributaries, s^wfrs = 18.00ft d^wfrs = 18.00ft (bay trib) Pdl = 1.296 kips Pll = 5.676 kips MLL := 0.5-wll-(Lt)^ MLL = 38.718 ftkips Seismic Load (per column): seismic response coefficient, Cs W:= (RDL).(s^^„)-(d„^,s) V := CsW Mseis:= (V)-(Hcol) Horizontal Seismic Load Effect: redundancy factor, p := 1.3 QE:= V Eh:= P-QE Mgh- Eh(Hcol) Vertical Seismic Load Effect: From page 6, SQS = 0.823 Dead load, D := W Ev:= 0.2-SDS-D 0.5486 W= 1.296 kips V = 0.711 kips Mseis = 6.399 ft-kips QE = 0.711 kips Eh = 0.924 kips MEh=8-319ft-kips D= 1296.00 Ibf Ev= 0.213 kips dead load on column seismic load on column Baja Construction Co., Inc. 223 Foster Street Martinez, CA 94553 (800) 366-9600 Page 13 Job #9791 Wind Load (each bay): Design wind pressure (page 3), Pfrm^ind = 14.062psf Fw:= (co-Pfrmwind):(s)(2.31-ft) Fw = 0.14kips Mwind := (Fw)-(Hcol) Mwind = 1.266 ft-kips total wind load each bay load per column Column Loads, cont.: Hcol = 9.00 ft Lt= 15.67 ft Wind Load (each bay): w^ind = 318.54plf P2 := (wwi„d)-(0.5-Lt) P2y := P2-cos((t)) x2:= 2.11-ft P2x := P2-sin((|)) y2 := 9.29-ft Wiee = 79.63ftpsf Pl := (wiee) (0.5-Lt) Ply:= Pl-cos((|)) xl := 11.li ft Plx:= Pl-sin((|)) yl := 8.74 ft Mwind := P2y (x2) -I- P2x y2 -f Ply-(xl) -f Plx (yl) P2 = 2.496 kips P2y = 2.492 kips (vert, component) P2x = 0.131 kips (horiz. component) Pl = 0.624kips Ply = 0.623 kips (vert, component) Plx = 0.033 kips (horiz. component) Mwind = 13.680 ft-kips Vertical wind component: Pwind:= (Pl + P2)cos((t)) Pwind = 3.115 kips 14- 18'-0'/<6" CROSS-SECTION WIND LOADING C:\Users\danilo\DccumenB\CALCS & DW6 TEMPLATES\BOXED FC 8l TEE\FC full cantileu«\9791-FC-SSS WCMV979l-P.dwg, 12/13/20119:34:59 AM, 1:41.1708 Baja Construction Co., Inc. 223 Foster Street Martinez, CA 94553 (800) 366-9600 Page 15 Job #9791 Columns: (2) Cee 16" x 4.0" x 12ga boxed Hcol = 9.00 ft Smwfrs = 18.00 ft ^mwlrs = 18.00 ft Allowable Axial Stress: Fy := 55.0-ksi Ky := 2.1 Kx:= 2.1 f Ky•Ly^^ Fe:= = 4541.37 n^-E E := 29500-ksi Ly = 9.00ft Lx = 9.00ft Kx-Lx^^ = 1423.52 max KyLy^ f Kx-LxV ;.c:= p yl Fe Fn:= if ^c> 1.5, X,c = 0.926 1^0.877^ / xA •Fy,\0.658^''j-Fy Ae:= 5.3078-in^ Pn := AeFn Pn Pa := Pn Qc ly := 3.3655-in rx:= 6.0112-in Fe = 64.11ksi Ly := Hcol Lx := Hcol Fn = 38.41 ksi fic:= 1.80 Pn = 203.86 kips Pa= 113.26 kips Alternate Basic Load Combinations per CBC Section 1605.3.2: Equation 16-16 Equation 16-17 Equation 16-20 Equation 16-21 D-i-Lr D + (oW D +E/1.4 0.9 D +E/1.4 Check Column perASCE 7. Section 12.2.5.2 For seismic load combinations, column axial loads shall not exceed 15 percent of allowable. Total axial load on column in combination with seismic load due to dead load onlv: W := RDL-(s„,^^)-(d„^„) W = 1.30 kips W W= 1.296 kips Pa = 0.01 Use of cantilevered columns as seismic force resisting system is acceptable. Baja Construction Co., Inc. 223 Foster Street Martinez, CA 94553 (800) 366-9600 Page 16 Job #9791 Column Load Combination: Dead Load + Roof Live Load Qb:=1.67 Ix := 190.9277in'* Sx := 18.6758-in^ Cmx:= 1 ^•E-Ix Mnx := SxFy Mnx = 85.60 ft-kips Pex := -^^^—^— Pex = 1080.70 kips , Qc-(Pdl-f Pll) ax := 1 ax = 0.9884 Pex Qc (Pdl -f Pll) ^ Qb-Cmx-(MDL -f MLL) _ ^ (Kx-Lx) Pn Mnx-ax <or= 1.0 O.K. Load Combination: Dead Load + Wind Load Qc(Pdl) ax:= 1 Pex Dc(Pdl) nbCmx-(MDL + Mwind) Pn ax = 0.9978 = 0.45 Mnx-ax < 1.33 O.K. Load Combination: Dead Load + Seismic Load /1.4 Qc-(Pdl -f- Ev) ax := 1 - • Pex ax = 0.9975 Oc-(Pdl + Ev) Pn Qb-Cmx- -f • MEh^ MDL+ — = 0.30 Mnx-ax < 1.33 O.K. Load Combination: 0.9 Dead Load + Seismic Load /1.4 Qc-(0.9-Pdl -f Ev) ax:= 1 Pex Qb Cmx- 0.9-MDL + Qc-(0.9-Pdl + Ev) ^ I L4^ ^ Q 28 ax = 0.9977 Ma Pn Mnx-ax < 1.33 O.K. Baja Construction Co., Inc. 223 Foster Street Martinez, CA 94553 (800) 366-9600 Page 17 Job #9791 Pier Footing: 30"(|) Caisson Hcol = 9.00 ft Max. Moment, Mmax := M^L + max(MLL,0.75-Mwind,Qo-Mseis) Mmax Equivalent Point Load, p := Hcol P = 5.28 kips Mmax = 47.56 ft-kips psf Allowable lateral bearing pressure Sa= 150.00-'-— ft Pole diameter (or diagonal) b := 30.0 in Structure is not advereely affected by 1/2" ground motion ~ use twice value of Sa Constrained pier embedment depth Dconst := 6.5 ft S3 := 2-Sa-Dconst ••const := 4.25. P-HcoH , S3-b , 83 = 1950.00 psf dconst = 6-44 ft Unconstrained pier embedment depth Dunconst:= 10.00-ft Dunconst S, := 2-Sa-S, = 1000.00 psf A:= 2.34-P S,-b A = 4.95 ft •*unconst Af, , 4.36-Hcol := — 1 -f l-f 2{ ^ A dunconst = 9-86 ft Use: 30"(|) x 6'-6" deep constrained pier footing (at concrete slab) or Use: 30"(|> x lO'-O" deep non-constrained pier footing (at asphalt/soil) Baja Construction Co., Inc. Page 18 223 Foster Street Job #9791 Martinez, CA 94553 (800) 366-9600 Check Pier Footing for Vertical Loads (DL+LL): Dpier:-Dconst Max. Vertical Load p := Pdl -f Pll P = 6.972 kips Pier Diameter b = 30.00in r:= 0.5-b r= 15.00in Using Fiiction Capacitv: SBPalloYy Allow. Skin Friction Ff := Ff = 250.00 psf 6 Pier Capacity Cap := ;i-b-Ff Cap = 1963.50 plf Friction capacity F := (Cap)-(Dpier - l.O-ft) F= 10.80kips ~ O.K. (neglect top 1.0 ft) Check Pier Footing for Uplift Loads (DL+Wind): Pufrm.wind = 12.478 psf s„,^„ = 18-00 ft d„,^s = 18.00 ft Uplift := ((a-Pufr„,^i„d - 0.67-RDL)-(s„,^rs)-(d^^rs) Uplift = 4.39kips Weight of footing Wftg := (145-pcf)-(7i-r^)-(Dpier) Wftg = 4.63 kips Weight of Soil Pier depth Dconst = 6.50 ft Pier diameter (bottom of fiustum) b = 2.50 ft r = 1.25 ft Radius top of frustum bftustum := r + "^"f , bf„stum = 5.00 ft tan(60-deg) Volume (frustum) ^frustum 0.333-7r-Dconst-(r2 + i-bf^tum + bfrustum^) Vfrustum = 223.34 ft' Volume (pier) Vpier := Ti-r^-Dconst Vpier = 31.91ft' Volume of soil V^oii := Vf^stum - Vpier v,oii = 191.43 ft^ Soil density Psoil := 110-pcf Weight of soil W,ou := Vsoir(psoii) W^oii = 21.06kips Wftg + Wsoil FS:= — FS = 5.85 Uplift Baja Construction Co., Inc. 223 Foster Street Martinez, CA 94553 (800) 366-9600 Page 19 Job #9791 Column Embedment: Maximum overtuming moment, Mmax = 47.56 ft kips Concrete Strength f c := 2500-psi Allowable concrete bearing Fbrg-= 0.3-fc Fbrg = 750.00 psi Column flange width b := 8.0-in w := (Fbrg)(b) w = 72000.00 plf j 6-Mmax dreqd:= d^qd = 23.89 m •\| w Column embedment depth d := 24.0 in Allowable moment Ma:= 0.5-w-f-^ J-f-^d ^ • —-f -CJ -a ? CNiIrn ? -CD 1 Ma = 48.00ft-kips ~ O.K. Baja Construction Co., Inc. Page 20 223 Foster Street Job #9791 Martinez, CA 94553 (800) 366-9600 Check Columns for Longitudinal Lateral Loads (weak-axis): Hcol = 9.00 ft dmwfrs = 18.00 ft Dead Load -I-Live Load Dead load on column, Pdl = 1.296 kips MDL= 8.840ft-kips Wind Load: Max wind pressure, Pfi-m^^ind = 14.062 psf (apply to 2-0 " veitical proj ection) Fw:= ((D Pfnnwind) (dmvvfrs) (2.0 ft) Fw = 658.10 Ibf total wind load Mwind := (Fw)-(Hcol) Mwind = 5.923 ft-kips load per column Seismic load per column (see above): W = 1296.00 Ibf dead load on column V = 0.711 kips seismic load on column Mseis = 6.399ft-kips Horizontal Seismic Load Effect: QE = 0.711 kips Eh = 0.924 kips MEh= 8.32 ft-kips Vertical Seismic Load Effect: Dead load, D := W D = 1296.00 Ibf Ev := 0.2SDSD EV = 0.213kips Baja Construction Co., Inc. Page 21 223 Foster Street Job #9791 Martinez, CA 94553 (800) 366-9600 Check Columns for Longitudinal Lateral Loads, cont: (2) Cee 16" x 4.0" x 12ga boxed Allowable Axial Stress (see above): Pn = 203.86 kips Pa = 113.26 kips Combined Loading - Dead Load + Wind Load fib := 1.67 Ix = 190.9277 in'* Sx = 18.6758 in' Cmx := 1 Iy:= 60.1208 in'' Sy:= 15.03-in' Cmy:= 1 Tc'^-E-Iy Mny := Sy-Fy Mny = 68.89 ft-kips Pey := — Pey = 340.30 kips (KyLy)' , Qc(Pdl) „_^„ , fic-(Pdl) ax := 1 —- ax = 0.9978 ay := 1 —- ay = 0.9931 Pex Pey Oc-(Pdl) ^ fib-Cmx-(MDL) ^ nb-Cmy-(Mwind) _ ^ < 1.33 O.K Pn Mnx-ax Mny-ay Load Combination: Dead Load -I- Seismic Load /1.4 , Qc-(Pdl-fEv) , Qc-(Pdl-HEv) ax := 1 ax = 0.9975 ay := 1 ay = 0.9920 Pex Pey Qc-(Pdl -I- Ev) nb-Cmx-(MDL) 1.4 J Pn Mnx-ax Mny-ay Load Combination: 0.9 Dead Load •+ Seismic Load /1.4 , fic-(0.9-Pdl-1-Ev) , Qc (0.9-Pdl-f Ev) ax := 1 5^ ax = 0.9977 ay := 1 ay = 0.9927 Pex Pey = 0.33 < 1.33 O.K. nc-(0.9-Pdl + Ev) Qb-Cmx-(0.9-MDL) 1.4 j = 0.31 < 1.33 O.K. Pn Mnx. ax Mny-ay Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Title: Dsgnr: Project Desc: Project Notes: Job# Printed:13DEC2011, 9:51AM General Footing MCS & DWG TEMPLATESIBOXED FC & TEE\FC full canfilever\9791-FC-SSS WCM\9791 spread fooling-FC.ec6 k ENERCALC, INC. 1983-2011, Build:6.2.10.00, Vef:6.2.10.00 | 1 Lie. #: KW-06001322 -Licensee : ROBERT FREDDY Description: Spread Footing-FCt-#9791 General Information Calculations perACl 318-08, IBC 2009, CBC 2010, ASCE 7-05 Material Properties f'c: Concrete 28 day strength fy: Rebar Yield Ec: Concrete Elastic Modulus Concrete Density 9 Values Flexure Shear Analysis Settings Min Steel % Bending Reinf. . Min Allow % Temp Reinf. Min. Overturning Safety Factor Min. Sliding Safety Factor Add Ftg Wt for Soil Pressure Use ftg wt for stability, moments & shears Include Pedestal Weight as DL Dimensions 2.50 ksi 40.0 ksi 3,122.0 ksi 145.0 pcf 0.90 0.850 0.00140 0.00180 1.50 1.50 Yes Yes No Soil Design Values Allowable Soil Bearing Increase Bearing By Footing Weight Soil Passive Resistance (for Sliding) Soil/Concrete Friction Coeff. Increases based on footing Depth Footing base depth below soil surface = Allowable pressure increase perfoot of deptl= when footing base is below = Increases based on footing plan dimension Allowable pressure increase per foot of depI = when maximum length or width is greater4 1.50 ksf No 150.0 pcf 0.30 2.0 ft ksf ft ksf ft Width parallel to X-X Axis = 7.50 ft Length parallel to Z-Z Axis = 4.50 ft Footing Thicknes = 30.0 in Load location offset from footing center... ex: parallel to X-X Axis = -21 in ez: parallel to Z-Z Axis = 0 in Pedestal dimensions... px: parallel to X-X Axis = in pz: parallel to Z-Z Axis : In Height ~ In Rebar Centeriine to Edge of Concrete., at Bottom of footing = 20.0 in Reinforcing Bars parallel to X-X Axis Number of Bars Reinforcing Bar Size Bars parallel to Z-Z Axis Number of Bars Reinforcing Bar Siz( Edgel Edgel Edgel Edgel Edgel »g r 6" r- CO 10.0 # 5 16.0 / # 5 Bandwidth Distribution Check (AC115.4.4.2) Direction Requiring Closer Separationig Z-Z Axis # Bars required within zone 75.0 % # Bars required on each side of zone 25.0 % Applied Loads mm lli&Nllilll^lllNlftaslllMMm»^illill(^ Mm D Lr L S W E H P: Column Load OB: Overburden 1.296 5.676 3.115 0.2130 k ksf M-xx M-zz 8.840 38.718 5.923 13.680 6.399 6.399 k-ft k-ft V-x V-z Title Block Line 1 You can change this area using the "Settings" menu item and then using the "Printing & Title Block" selection. Title Block Line 6 Title: Dsgnr: Project Desc: Project Notes: Job# Printed: 13 DEC 2011, 9;51AM General Footing ^LCS & DWG TEMPLATES\BOXED FC & TEE\FC full cantilever\9791-FC-SSS WfCM\9791 spread footing-FC.ecS \ ENERCALC, INC 1983-2011, Build:6.2.1Q.0O, Ver:6.2.10.00 | lLlc.#: KW-06001322 Licensee : ROBERT FREDDY Description: Spread Footing-FCt-#9791 DES/GA/Sl/iWM/ARy Min. Ratio Item Applied Capacity Governing Load Combination PASS 0.9847 Soil Bearing 1.477 ksf 1.50 ksf •t-D-HLr-i-H FASS 4.153 Overturning - X-X 4.479 k-ft 18.601 k-ft 0.6D+0.7E PASS 1.771 Overturning - Z-Z 47.558 k-ft 84.225 k-ft D-nLr PASS n/a Sliding-X-X 0.0 k 0.0 k No Sliding PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding PASS n/a Uplift 0.0 k 0.0 k No Uplift PASS 0.9045 Z Flexure (-^X) 17.683 k-ft 19.550 k-ft +1.20D-i-1.60Lr-K).50L-K).80W PASS 0.02411 Z Flexure (-X) 0.870 k-ft 36.083 k-ft -Hl.20D-Hl.60Lr4O.50L PASS 0.07096 X Flexure (+Z) 1.335 k-ft 18.811 k-ft +1.20D-K).50Lr-tO.50L-Hl.60W PASS 0.04240 X Flexure (-Z) 0.7976 k-ft 18.811 k-ft -Hl.20D-Hl.60Lr-K).50L PASS 0.1792 1-way Shear (-HX) 15.235 psi 85.0 psi •Hl.20D-Hl.60Lr-K),50L-K).80W PASS 0.04576 1-way Shear (-X) 3.890 psi 85.0 psi •Hl.20D-Hl.60Lr-fO.50L-tO.80W PASS 0.07517 1-way Shear (•^Z) 6.389 psi 85,0 psi -Hl.20D-K).50Lr-fO.50L-Hl.60W PASS 0.04449 1-way Shear (-Z) 3.782 psi 85.0 psi -Hl.20D-Hl.60Lr-HO.50L PASS 0.1921 2-way Punching 32.659 psi 170.0 psi -Hl.20D-Hl.60Lr-K).50L-tO.80W ill® Featuring ZincaIume®For Twice the Life! Zincalume combines the strength of steel with the corrosion resistance of aluminum for twice the life of most zinc coatings. AEP^ SPAN A BlueScope Steel Company features I benefits B Long spanning capability and its design provides superior load and span capacities, saving money in the structural support system. H Standard trim pieces are available and can be ordered by number. E 26 gauge panels available in the Cool DuraTech®nt coating system or Zincalume Plus for unpainted applications. M 29 gauge panels available with the ColorGuard™xf coating system in Desert Beige, Surf White, and Zincalume Plus for unpainted applications. ^' :::•:•••:-:!! : Gauge.* • • • "-tn 29 0.725 0.1046 ,0.1170 0.0851 0.1117 26 • 0.906 0.1417 0.1490 0.1154 0.1440 Project: Model: SECTION DESIGNATION: Cee 8 x 3.5 x 16ga Single C Stud INPUT PROPERTIES: Web Height = Top Flange = Bottom Flange = Stiffening Lip = OUTPUT PROPERTIES: 8.0000 in 3.5000 in 3.5000 in 1.0000 in Steel Thickness = Inside Comer Radius = Yield Stress, Fy = Fy With Cold-Work, Fya^ 0.0600 in 0.1250 in 55.0 ksi 55.0 ksi ^0 Effective Section Properties, Strong Axis Neutral Axis from Top Fiber (Ycg) IVIoment of Inertia for Deflection (Ixx) Section Modulus (Sxx) Allowable Bending Moment (Ma) Gross Section Properties of Fuil Section, Strong Axis Neutral Axis from Top Fiber (Yog) Moment of Inertia (Ixx) Cross Sectional Area (A) Radius of Gyration (Rx) Section Properties, Weak Axis Gross Neutral Axis (Xcg) From Web Face Gross Moment of Inertia (lyy) Radius of Gyration (Ry) Other Section Property Data Member Weight per Foot of Length Allowable Shear Force In Web (Unpunched) Pao for use in Interaction Equation C5-2 Torsional Properties Dist. from Shear Center to Neutral Axis (Xo) St. Venant torsion Constant (J x 1000) Warping Constant (Cw) Radii of Gyration (Ro) Torsional Flexural Constant (Beta) 4.3622 in 9.7024 inM 2.0351 in^ 3 5585.29 Ft-Lb 4.0000 in 10.1768 InM 0.9896 in'^2 3.2068 in 1.1243 in 1.7247 InM 1.3201 in 3.3675 Ib/ft 2519.65 Ib 163071b -2.8017 in 1.1876 inM 23.9086 in^6 4.4582 in 0.6051 Project: Model: 2001 NASPEC w/2004 Supplement SECTION DESIGNATION: (2) Cee 16 x 4 x 12ga Boxed C Stud INPUT PROPERTIES: Web Height = 16.0000 in Top Flange = 4.0000 in Bottom Flange = 4.0000 in Stiffening Lip = 1.0000 in OUTPUT PROPERTIES: Steel Thickness = Inside Comer Radius = Yield Stress, Fy = FyWith Cold-Work, Fya = 0.1050 in 0.1250 in 55.0 ksi 55.0 ksi Effective Section Properties, Strong Axis Neutral Axis from Top Fiber (Ycg) Moment of Inertia for Defiection (Ixx) Section Modulus (Sxx) Allowable Bending Moment (Ma) Gross Section Properties of Full Section, Strong Axis Neutral Axis from Top Fiber O'cg) Moment of Inertia (Ixx) Cross Sectional Area (A) Radius of Gyration (Rx) Section Properties, Weak Axis Gross Moment of Inertia (lyy) Radius of Gyration (Ry) Other Section Property Data Member Weight per Foot of Length Allowable Shear Force in Web (Unpunched) Pao for use in Interaction Equation C5-2 8.8233 in 190.9277 inM 18.6758 in'^ 3 51256.07 Ft-Lb 8.0000 in 191.7918 inM 5.3078 in'^2 6.0112 in 60.1208 inM 3.3655 in 18.0613 Ib/ft 13260.461b 73793 Ib Geotechnical Exploration, Inc. SOIL AND FOUNDATION ENGINEERING • GROl/NDWATER • ENGINEERING GEOLOGY 30 October 2006 THE ALLEN GROUP Job No. 04-8756 6005 Hidden Valley Road, Suite 150 Carlsbad, CA 92009 Attn: Mr. Harve Fllul< Subject: Earthwork Observation and Testing Services Kelly Ranch Corporate Center - Parcel 4, Building 3 Carlsbad, Caljfornia Gentlemen: In accordance with your request, Geoteehnical Exploration, Inc. has provided earthwork observation and testing services In connection with the subject project. Robert Prater Associates (RPA) previously performed a geotechnical investigation for the entire Kelly Corporate Center site, the results of which were presented in their report titled "Geotechnical Investigation for Kelly Ranch Corporate Center, Palomar Airport Road and College Boulevard, Carlsbad, California" dated April 30, 1997. In addition, RPA provided earthworlc observation, testing, and as-built geology services in connection with the previous mass grading and construction of existing improvements, including Building Pads 1, 2A, 2B and 3, the results of which were presented in their report dated April 12, 2000. In addition, RPA also performed an update geotechnical reconnaissance for the subject building project the results of which were presented in their report dated July 19, 2004. We previously issued an interim grading report dated July 15, 2005, as well as letters dated January 30, March 27, and April 7, 2006, regarding base under on-site curbs and gutters and presenting R-Value test results and pavement section recommendations for the on-site pavements and the Palomar Airport Road improvements. 7420 TMJE Smn» SAN DEGO, CA. 92121 • (858) 549-7222* FAX: (858) 549-1604 • EMAIL: geotecti@gel-sd.com mm Kelly Ranch Corporate Center - Parcel 4, Building 3 Job No. 04-8756 Carlsbad, California Page 2 During the period of October 12, 2004, to August 21, 2006, our representatives were present to observe the earthwork operations and to provide field density testing services. The approxtmate locations of the field density tests are shown on the attached Figure Nos. I through III. The results of the field density and laboratory compaction tests are presented in the attached Tables A and B, respectively. We also provided footing observation services for the subject building and the central plant. Based on our observations and the attached test results, It is our opinion that the soil engineering aspects of the mass grading are in compliance with the approved geotechnical report(s) and the grading and Improvement plans. Details regarding our earthwork observation and testing services are as follows. MASS GRADING The mass grading operations Included additional removal and recompaction of alluvial soils along portions of the northern and eastern building perimeters, as well as the central portion of the southern perimeter and the area of the mechanical building (see attached Figure No. III). The recompaction work consisted of removing alluvial soils to within a foot of the ground water levels and refilling the excavations with compacted structural fill. Portions of the excavation bottoms required stabilization with reinforcing fabric and/or a layer of compacted aggregate base. After the recompaction work these areas were surcharged in conformance with the plans (see attached Figure No. IV). Prior to the placement of the surcharge fill, one settlement monument was installed on each of the new recompaction areas and monitored for a period of about 7 weeks. The approximate locations of the monuments are indicated on Figure No. IV. Based on our review of the data, settlements of up to about 0.04 feet occurred from the surcharge load and were Kelly Ranch Corporate Center - Parcel 4, Building 3 Job No. 04-8756 Carlsbad, California Page 3 essentially complete in about 10 days. The results of the settlement data are presented on the attached Figure No. V. Subsequent to the completion of the surcharge period and removal of the surcharge fills, the building area was finish graded and capped with an 8-inch thick layer of low expansion potential imported fill soil; an additional 4-inch thickness of low expansion potential fill was placed as part ofthe building slab construction. Based on the preceding, it is our opinion that the building pad was suitably prepared for construction of the proposed building in accordance with the recommendations ofthe update geotechnical reconnaissance report dated July 19, 2004. TRENCH BACKFILL Based on our observations and attached test results, it is our opinion that the sewer, water, storm drain, TV, telephone, site lighting, and gas and electric trench backfills were compacted to a minimum of 90 percent relative compaction in accordance with the project specifications. PAVEMENT Based on our observations and the attached test results, it is our opinion that the following items of work were satisfactorily completed in accordance with the project specifications. 1. Preparation and compaction ofthe pavement subgrade soils to a minimum of 95 percent relative compaction. 2. Placement and compaction of aggregate base for the pavements to a minimum of 95 percent relative compaction. Kelly Ranch Corporate Center - Parcel 4, Building 3 Job No. 04-8756 Carlsbad, California Page 4 3. Placement and compaction of asphalt concrete to a minimum of 95 percent relative compaction. FOOTINGS Our representatives were also onsite to inspect the materials exposed in the footing excavations for the subject building and central plant. The materials consisted essentially of well compacted silty and clayey sand fill soils as anticipated in the April 30, 1997, RPA investigation report. Accordingly, it Is our opinion that the footing excavations were carried to the proper depth and that the materials exposed are suitable for the support of footings designed in accordance with the recommendations presented in the April 30, 1997, report for the project. LIMITATIONS Our services consist of professional opinions and recommendations made in accordance with generally accepted geotechnical engineering principles and practices. This warranty is in lieu of all other warranties either express or Implied. This opportunity to be of service is sincerely appreciated. Should you have any questions, please do not hesitate to contact us. Reference to our Job No. 04- 8756 wili expedite a response to your inquiries. Respectfully submitted, GEOTECHNICAL EXPLORATION, INC. Wm. D. HesfJeler, G.E. 396 Senior Geotechnical Engineer BEST COPY IS ill BEST COPY o z o < U . 6 o I Co CJl 05 o o I 00 CD CD 3 CD CD 0) Co C 3 CD D Elevation Cfect) 00 oo 00 ^ o o Elevotion Cfeet' CO III oa S2. p «< -CL---. ^ 1 .... r 1 ii. C I „ C ^ i X O 3 c 3 3 z o s- CO CO NJCli w = S 1 (It CD is Tl -n TJ DO Q O a. CL. CD (D 3 3 O O CD CD m VI «' OJ' 3- 3-T3 (T 0) Q) CD CD 3 to ^ CL (Q CD Q. CD "I O 3 CQ H -I CD CD CD 03 % ffi 5" 3 c<> ro M ro ho N> s> o (o OS .-g a> cn A O(oao->ja>cn.^0}io 9 P o p A 4>> 2 g o 3 o o g 2 M IO S O s s o _ 5* p a o 4>. *• g m m m m a> a> a> 01 m rn m m m m m ffl m 01 01 IS CD D) m m __ _______n)oi S5.SS.SS.SS.S2.!S.SiS2.iS.S2.i2.SS.S 2? S 3? 3" Cb <D (D 8 9 3 3 8 § 3 3 ^ ^ 'S s I-111 3 3 3 3 > > ^ 3> ^ i s i 3? 5 5 3? 7) 30 30 (p (D O (P CD <D CD 8 8 8 8 8 8 8 3 3 3 3 3 3 3 S ^ ^ "S ^ s a 3. i a a. a a o 5 o o o o o 3 3 3 3 3 3 ^ ^ > ^ > > S ep <p <D CD CD m D) w 9 fD 8 8 3 3 Bl S a a o o 3 3 >>>>>>> CD CD 0) m m m 0) a> a a 8 § 3 3 II 3 3 5' (D rnrnrnrnrnrnrnmmmmmrnrnrn IUtDfi0IUI^SDIUOjfUIUfiDffll3afl>(U tau)(o(A(/io)(«(oucACAwcawa) 30 30 30 30 30 30 XI CD $ CD CP CD <P CD 8 8 8 8 8 8 8 3 3 3 3 3 3 3 III 3 3 3 3 3 3 3 ^ ^ > ;> > ^ > <D (D CD CD CD CD (D D> IU CU (U m lu (5 •a -o at m _ _ ^ B 1111 8 8 3 3 71 30 3D 30 CD CD CD CD 8 8 8 8 _ 3 3 3 3 ^ IS ^ ^ ^ ^ 111111 3 3 3 3 3 3 > 5 ^ > > ^ i i g s i I s a. « § r m > 1 (0 c s I o o a m z (0 3 •n oi"^tjibibi6ibibicnbi bibitnuibiai cn cn P !i i *• 10 C» M CAI M O C]> CO cn 5? m (0 c > 3s| I cn MUMcncnSsuaA^u^o^oSSSp^a^luu ^N3boK3b>vibo<3<D^O~jkj^bi^cnwwwMb>bo^w a bS o «-3 I I ____ _ , _00CD<DCQCD<O<O(D<DCDCO00 if ^ sll a IS ION)MIO.U.b.tk.b.U4!^COUO>C<>Cj}a>C>}C«)CdCdA.b.^N>N>N>IO-^ P o 3 O CD S ft 0) » 9 * CD' Q. ^ -Cfl * 00 i' 5* I i CA) - cn CD CD * ^ 5* ID a a CO U) ..A CD (D M ft CO a u e 09 0» 13 D> CO CD o a a cS^ cn ^ ^ ro, Tl Tl Tl TJ DJ CO OOO a. a. a. CD (D (D 3 3 3 c i 3 0003 CD CD CD CA CA 0> CD =t} :A :S> -, Cfl CO CA cT X3 O" B) to < (A CD CD 3 CQ ^ o. (O <D S 2. O. CD o" 3 (Q H -I CD CD ffl DO s o 3 N3 N3 R ^ ^ ^ A y •A .A 19/04 g OS g 09 s 1 CO g OD go 0 00 g 00 0 09 0 1 OS g -.1 g •>i g g -J g 0 g g 3 i a o 3 0) z z z z z 00000 i i i § 5 71 30 X 3D 7) 8 § § § § 33333 TJ T3 TJ T3 03 Dl Ql D> D> a a a a a § § § § i 0) D) (U OS Q> m m rn m m rn rn Q) 0) Q> D) Q] D) 01 a a a a a a a 71 71 7) 71 7} CD CD CD CP 8 8 8 8 3333 TJ — — — 0) ft O" 3 m m m 0) a a m m m 0) a. a § 8 § 3 3 3 •O TJ TJ tt 0) g> I I I 333 ^ ^ ^ ? ? ? CD CD m 0) 3 i _ I I 1 333 ^ ^ > s s ^ 3 3 3 3 'S 0) I I 3333 ^ 5- ^ ? CD CD CD CD 0) ju iS 0) m m Q> 0) o> cn i i 8 § 3 3 m ^ a a O O 3 3 so sa m m sa at 3 3 3 ^ ^ ^ a a a 000 333 > ^ ^ CD CD CD 0) 0) 0) m m at D) a a CD CD 8 8 3 3 II 3 3 ^" ^ CD CD 01 O m m 0) D) a a CD CD 8 8 3 3 a Q-o S' 3 3 m m 0> OS a a CD CD 8 8 3 3 m m 0) 01 a a 3 3 1111 3 3 3 3 ^ > ^ > s i s s i I 9 00 Ul a» r3ooS-2N;:4-4-4-«|^24NS*!*.*k*.4».^o3>!5!c»iCA)>*.coc*) bl 01 bi cn cn ^ ^ ^ °^ cn cn cn cn cn cn cn cn cn cn cn cn cococoMroroioNJOiococooioiooio.^'O.^wcn-jioo.^.^ro.^ pcn^iocnaaa3:-^!oiooi^co.^AcowNa>!OMjocoAa coba^)^bicD^co^->ib9uk>aioauco^coaok>^aiCia>Kj O 00CD<DCD<DCDCOCDCDCDCDCO<D(D(DC0CDCDCDCD<O<D00CDCOCO00CDC0 2 a •> lo^>^o^oloco^J^o^o^3l^J^J^J^3lo^o^3^J^3^>^3^J^5^J^J^3^5^o^l^J 3 CD CD ft O) 1^ a g CD ft ft Oil 00 CD ft o CD <-* a 3" II CA> tn ^ CD CD ft TJ Q> (Q CD NJ 2 o r-»* CD Cfl CO c ?^ Q- -. 2. 3 (0 CD TJ DD 0 O a a. CD ffl 3 3 a a CD ffl 01 (0 ai =3> 3 3 ai' w" 3- 3- T3 cr < CA ffl ffl 3 (Q ^ Q. (Q ® S <L Q. CD » § 3 ffl -I ffl ffl ffl 03 ffl < so S. o 3 mooooooooooooooooooos^^S ocoao-gaicn^oiNj-^ocooo-.] ^^•>i^->i^-.icj)roaio>c» oicnAcdM-i'Ocoao^cJicn g NSMNSiMMNSNSrSioro toro-k-*-'-»-»oop gggggggggggffgg tJCJfcJfcJfoiofoS P :^ ^1 S S o P ° I? CA cn o o c 70 3 TJ 01 I 3 0] CO CA O O c c 5 S 71 73 CD CD 8 8 3 3 a a o s- 3 3 > > 0) 01 c c 3= 5 7} 73 CD CD 8 8 3 3 II 3 3 > > 0) 0} c c 5 5 7} 71 CD CD 8 8 3 3 TJ TJ 01 01 a a o o 3 3 > CA _ o c c 3 3= CA cn o o c c 3 5 X 3D 33 3 CD cp CD CD 8 8 8 8 3 3 3 3 TJ TJ TJ TJ 0) 0} 01 0) ^ ^ i- - - 3 3 > > 73 X i § 3 3 TJ TJ 01 01 a a z z 0 o § § § § 3 3 TJ TJ 01 01 2? «P ? CD CD 9 -A —& —A ^ -A o3 K5 io ivj p o o o CD CO CO CO o g 1 g f 2 g § g g 2 Z Z z z Z z Z Z Z z z o o o o o o o o o o o rth rth i i rth i rth rth rth rth rth 5" .o 55- 5P ? 3" 3 3 > > 3 S 01 01 01 II 3 3 3 > 0) 01 CD CD fll 01 3 3 3 Tl TJ TJ 01 Dl 01 a o Q CE =S ooo 3 3 3 m ^ m CD CD CD 3 3 TJ TJ 01 01 II 01 01 3 s 30 3D i § 3 3 TJ TJ 01 Dl a a Q O § 8 3 3 TJ TJ a a o o Dl 01 0) 01 2" S S § § 8 3 3 3 TJ TJ TJ 01 01 01 a a a ooo 3 3 3 u m ^ g CD CD 01 01 •0 # a a>a>cJlal4^.^.4^^J^J^JCdMOoocJ)a)^j>lcoo^Jocncn.l^cJlCAl4^^ro bibibibibiwbibibibibibibibiOTbibi biwibibibibiw > ml 3?l I -'->'IOOCON].|^CO.^KJ.^CnlOIO-^4>'4>'4^-^ o S -'cnMcnc«>-»Mio(o-»co O «^Mwu^Mcn>w^MitSmpj^^cnu cou^co'.b^iuouiboubcobi^(oa>b9^bihj(oKJAao TJ 0) CO ffl .(k.(>.|OIOIOKJKJ4^A.^MrOCOCOCOIOIOIOMrOI\}MIOIOMMIOIOIOIO 1^ IS ft CO o 3C CD II ^ SB ft cn i CD a ft z o ffl CA CO M , •n -n TJ 00 O O Q. a. ffl ffl 3 3 3 3 co' Cfl' ^ 3- TD cr 03 0) < en ffl ffl 3 (Q a a <Q ffl 3 ffl a. ffl cft O 3 -n p CO = i i a 3 CO ffl <» !!. (Q H i-r [U ^ ffl ffl ffl DO s a 5' 3 M Q cooo->icncn4^Ci3M->. o O CO ooo •vJ (31 Ol oooo CO lo o CO CO CO <0 CO CO 00 ^ Ol cn CO CO CO CO J. CO M pa cn Ol 01 O) 01 01 cn 01 01 CJl (Jl M 01 CJ) c» 2 S2 O) 2 2 N3 i3 ?3 R3 K5 i:3 N3 N5 fo N3 is M is NJ io i3 NJ _A Si SS £0 £0 SS £5 SS SS SS $S SS SS ^ o :y 2( 5I SJ o o o o O o o o o o o o o o o o o o o 0 0 0 0 cn cn cn cn cn cn cn cn cn cn cn Ol 01 cn cn cn cn cn cn cn cn cn cn cn NJ M NJ 13 NJ iv3 N5 13 io 5j 0 0 0 0 «. 4^ E. E. E. £. E. £. E. E. E. E. ^K5.a.5.S.S.S.5.a.5.S.K^Q 71 S' 3' 3' 3' 3' 3' 5" 3 3' 3' 3' 3' 0) u CDcocQ(0(ococacococo(aca(Q 3 3 8T3TJTJT3T3T3-PT>T1TJTJTJ DO ^DlQlDlDlCUaiQlDlOlIUDlDlDlOl 3a.cj.aa.a5.5.5.a.cia.cj.~~ TJ--- - - OBOD SJ3Q03mc8CflC533M3a5 QOCPCDOOOOOoOOOoS^ 5a aaSaaaaaall ^ 01 01 a a o o 3 3 0> CD Dl " -.^...,-,<^^.^^,_.«,«,«,_a»o'"i">y,~Wy,"'cn cncnencn "^ a>aia>aaia>c»oicncncncncn m m S M TJ O s Ul 01 r m > I (0 c s 5 O • m z tn u c 5 311 ->..t^COC0CO4^«..U00N}4i>CJICO — — — — — — .0* -.'O-»-O'°O-»C0IO->.C0IONlg^g •—' ^ ^ NjhOcnNJNJC]>cncocoN3a)Co-4NJ:U:t>'Cdtowprowpi:tkU coNjwco'cn!t^bi'.t^4^^oioboai^biKo'-^Kokibi^l^'oo'> cocnj>.cn.*. Bgj o 00 CO CO 3^ §O o COCDCO<OCDCOCO(OCOCOCD(O(D(D(OCD(OCOCO00CO(O(OCOCOCOCDCO(OCO I Tl ^ OONJOOC0NJ-'-»Sc0-'AO-»N>-»O-*0eOONJN3-»OIOO-'-'^SS la 3 fi NJNJN}N}NlNJNJIOION}NJN]NJ^J^}^JN3N}NlNJNlN]MNJ^]NJJ>..^.^.^.S^ s. P O Ul Ul 9 S 01 3 Q. 1 ID M N CO u 09 CS 2P S" CD (A SP *-»• a a; ft §; O N) 1 TJ QJ CO ffl 2 o .-1. ffl CO 3 "rt TJ DO O O Q. a. ffl ffl 3 3 a a ffl ffl CO CO 3 3 co' m 3- 3-TD CT at Q) 3 CQ a Q. CQ ffl s a CX ffl » 2 5' 3 Tl P CO = S I a 3 CO ffl 3 S sZ -I ffl ffl ffl DD ffl cr. o 3 en o CJl 4W o CO to CO M CD NJ Cn NJ NJ CO NJ L —, —^ s S N o o o 3 o cn cn cn cn cn w stf fo ^ ^ :^ :^ 5) NJ is § s g Ol s —i s —. s 3 cn S cn 3 cn 3 cn 3 cn CD 3 (O o CD 3 CD O (g o 00 o i § u o i cn cn 3 cn S cn 3 cn 3 cn 3 cn cn cn cn cn cn cn cn tn tn cn EC 2 2 ft I S 8 " ^ ^ m rn m m 05 Dl 01 01 01 c » CO CO m =: r... ..^ .-.• CJ. Q. Q. a QD CD CO OD ^ < i: i: C E. I f Q. Q. a g. a a § § li' 5' J J TJ "D TJ TJ 3. S-01 Dl 01 01 g. p. p. p. p. 3 3 g § 8 S 5" 5" 3- a s s. ^ r ? t aaa « ^ ^ c c S 3= T) Tl CO CA O O c c 3 3= TJ TJ m 01 a S 5 ^ 5 E CO z m ^ S 2 § 8 i 3 3 I TJ I I a f 3 > - ^ 5' I •0 J CD" a z p cn r m CO c s s I o n •n fn I-o o m z (0 TT -n CO CA O O cSo bo 'cn 'cn •n Tl CA a> o o H Tl CA CA o o •n Tl CO CO CO a in •>! ->i CO CO NJCocoANJCo-'->'^NJCn<:nNJcj> CO CO to CO -n Tl Tl n Tl CO CO CO CO O) O O O Q O Ol •>! CO -"•o-^-j.-'-^-^-A.-^ro-' 0100.UCOIOCDNJCOCJ10.tk 4^->(j>cocncncoao>j CO NJ NJ 09 cn CD00<O<O(O(O(O(OCOCDCDCDCD(0®COCOCO<OCD(O(OCD(OCDCOCOCOCOCO COIONJ-'00)0--'~5SSSf3eo3iOO-»CON>ONJO-*-»ONJON> NJNJNJNJNlNJNlNJCnNJNJNllONJCOCOOOCOOOIONJNJKJNJNJNJNJNJNJNJ CD r-f Q) il n Dl a P o 3 CD ft TJ 01 (Q ffl z o ffl CO ^ ^ NJ c; ^ P CO = a 3 CO ^ TJ DO O O a CL ffl ffl 3 3 O Q S' ffl eo CO 3 3 eo' «• 3- 3" TJ cr B) 0) < eo ffl ffl 3 CO ll (Q ffl S a CX ffl ffl < to f-l- o' 3 2- a CA s- CQ H 1 ft) ^1 ffl ffl ffl DO ffl < a 5' 3 k . .A k 00 ~j •H ~J o CO 00 01 cn to . —. ..A L NJ ts NJ NJ NJ NJ SS SS o 3 o o o o o o cn cn cn cn tn cn cn Ol cn tn cz ^ NJ p ft T) 3 OOOOOO S cn cn cn cn cn M NJ NJ NJ NJ O O O O O O o cn cn cn tn cn cn cn Nj^NJSS3cooo (6 CD 00 00 00 00 3 3 S S 3 o cn cn cn cn cn cn CO CO CO CO CO CO I a. g. g. 3' 3' 3' CO CO (Q > •nS 3 oicncncncncncncncncn _j._xrO-»'MOO-^-*-*--*-MN10CO C000*klO(J10lC0p(JlNJNJ;U*-(O7'ptn cDcoocoto^cnoo^botooo^Acooicn ro cn 4k o i cocococototn^^^ —^ —1 . 4>. tn to b 'o to ^ ^.i.^.ptnwco7<l bo(ONjai<30(ocnco 9 * 2S2ggS8SS8S§S8SS8Sf82f822f8g28S22ggg|| o c i MMNJNJNJNJMNJNJNJNJNJNJMNJCDNJMNJNJMNJNINJNJNJNJNJNJNJ P o 3 r m > I (A C 3 S > O m r-o o m z (0 Fl 7) in (A c 1 o cn Ul 9> (O o a 3 a o ! CO o u eo I? 3 Dl TJ Itt (O ffl OJ 2 o c? CA Jik CAJ N), Tl -n TJ DD O O Q. a. ffl ffl 3 3 a a cT ffl CO CO ai zsi 3 3 cn' «• 3- 3- •a CD-0) 01 < CO ffl ffl 3 CO a Ci CD ffl E3 a Q. ffl ffl < 0) 3? 11 CA CD ^ -I 3 ffl » 3* «^ ^1 (D ffl CD 03 ffl < 0) o' 3 N3NJNJNJNJNJNJNJNJNJN)-*-^-^-*-k-k-k-*-*—*-*'-*-*-*-*-k-.k-.k.k -i o OOOOOO 0 0(3CD(0(0(0(OCOCOCOCO«OOOOOoaOOQOOOOOOO ocDOo->ioicn*kcoNJ-»ocDOo-«ioicn*ktoNJ-»0(OOo-.io}CniktoNO-» ^ NJ N M N fs is NJ • • ss ss ss S S Ol S 8 ii-kiSNiiSNi-'-'-'-'ri^i-t 3 CJl gl o 3 o o 3 o tji cn 01 C3> (Jl Ol . . k NJ M ts ^ jn jn SS o o o tn tn tn zS" .oft g- =r =T CD CD CD CD 3 3 3 3 s- § § & 5 (D' a cn Ol |-m > • CO c s s I o m 5 o m z CO H m CO Tl Tl _ CO CO 3J c) « i. ik TI CO C« O A O A O A o Tl TiTJTJT^Ti "n'n"n"nTi-nTiTiTi-n -ncoTiCACocncococA-nTicocococococoCocococo coo«G)C)OOOoCOCOoonOOOCJOOO G) I I .1 ,1 ,1 I uJ <iJ I I I I I .... -'tntntntn-' - ^ n ^ tn tn tn tn -kOONlO-kOONJO-A-CONlNJ to CO NJ 00*»4^CJ00MN1 s § ^^aiOON903Cn(3>N3COCOpMO>pi;^;^fOtOC^(Q;s|po CDLLi^cna>^bbi03Ci)bci->ib!>M4»>b^Njbo^ O CO c 3fi ? oi 1 D tn en 7> ID O 01 3 I S COCOCDCDCD^COCOCD^COfiDCOCOCOCOtOCOCOCOCOCDCOfiOCpCOCOtDCO 0-SSo.SwSo-S.r:oiOtoN14k.(kOO-ktn.U4>.0 • NJ .k > CO *k.U4kl0l>j|OI0loNJNJNJNJM10NJMNJIOMNJNJNJNJNJN)NlNJNJI0NJ o a 3 CD 3 o o i-i O 01 a p o o M IS ls> O 3 Dl TJ Q) CO ffl •vl 2 o CD CA > CAJ MC; "^"^ P CO = § 1 a 3 ff S" CA CD :* 2. CD Tl -n T3 DD O O a CX ffl ffl 3 3 O Q 2 2 eo' en' 3- 3- TD CT SO Oi < CA ffl ffl 3 CQ § 3 a £X ta ffl 3 a a. ffl ffl < a o 3 CO a" -I ffl ffl CD. DD ffl < 01 5' 3 MrONJNlMMNJNJNJNJMNJ[ONJ|OIOjOM gSg353S5SgSS2gS8!i3K8!^SK!SgcD00^0101JkCONJ- 3i-a-4-j-j-.i~4--i^2j tn jn oooo Ol Ol Ol Ol S S o> 8 NJ NJ NJ NJ NJ p P p Ol CJl —X P O o o 3 o 3 O O Ol 01 01 Ol cn 01 Ol Ol s ss SS ss k . p (Jl o o s (Jl Ol (Jl p a a c3 Ol Ol < 5. TJ 01 CO CO CO CO oooo c= c c c 3 S 3 a a i- 3- . _ ^ £D_ ^ a. 3. < SD TJ 01 3 3 3 (O CQ (O 'S ^ m m m m 01 m 01 01 •"aaa a CJ. CJ. a. 3. 3. 3. a. < < 2 < S» SE. SS. 5. TJ TJ TJ TJ %% %% 5' 3' 3' 3 CQ (Q ID (O Tl 1 CD a z o Ul et r m > (0 c % o Tl Tl Fi r-o o m z CO 3 Itl c»5c«c«c2c«cac})'c«cHconomcqmMi^w^ Tl Tl Tl n CO Tl CO Tl CO Tl CO CJ « O M O « C) , O • GJ • O TiS 3 m S >< . . . J. » . k . k k —k MJ. oooopco«tDcofflcoco»cntncn.»(o«o-«4tn5^5j^(j.iioioKj.k|oojjg S § m CO c S 1 o .k cn ?* ID K!i:3?3!S«-S»p"§gSSg^SSSSpSt;tntoppa bKj«pikto^bbiNJ.UNJNJbiM«o®P-«'f>^"-*'"'^''° o o ^g8g5S^gSSSSS23gggSggSSS2S2SSgg|3 S J^Jk^kJk.t.MNJNJNJNJNjSg^PPdjSoP®'^'^'^'^'^^'^'^'^ il za P 5 3 I i CD a 3" i S ft NJ to CO 3 ft NJ CO O 2L O ft NJ S5 H H H CD <e CD 01 CA a 3" led. led. led. 01 cn CA CD CD CD CD CD ft ft ft to o g CO o 01 p CD CD 3 3 ? 1 D> 3 Ck I o Kl iS 1 D 00 00 TJ 0) CO ffl 00 NJNJNJNINJNJNJNJNINJNJNJNJNIMNJMNJNINJNININJNJNJNJNJNJIONJ ->iPcnoi(jicjidapcji<jia]cncntncncntntntntncn.UA4^4^.u.^.(k4k.u 0(OOo^aicn^6iNj-kOcoo9^aicn.utoNJ-kOCDOo-vipcn«kCONj-k ziS* pa TJ a z o ffl en TI p CO = °- % § i a 3 ff S" eo ffl =Sl -1 3. a TJ GO O O CX ffl CX ffl 3 o ffl eo CO CO IT =r T3 CT 0) Q> < eo ffl ffl 3 CQ ^ CX CQ ffl 3 a CX ffl ffl < a 5' 3 ^1 «> t ffl ffl CD DO ffl < a 5' 3 5! :^ :^ 13/06 13/06 13/06 13/06 13/06 13/06 13/06 13/06 13/06 13/06 13/06 oooooooo CO m m O m 01 CJ. m 01 <2. < < JD 5. TJ TJ 01 01 a * 3 3 (O CO §: §: I g. 2£ TT 3. 3 3' 3' =• CO (Q (Q ^ SE. SS. TJ P g> s s § s M (D CD CD CD ?L a a a ft 5' o. a. a. a. CD 3. ^. 3. ^. §' 5. SS. SD. SD §. ^ ffi ^ m S- S; S- S' 5' 3 3' 5' CO CO (Q CQ z z o o 5 5 g. Q. a. < S. 5. TJ TJ IB g] I' ^ TJ TJ 01 01 —. —1 3 3 CO CO m m m m m 01 01 01 U CD ft ft ft a a CL Q O. Q. CL —. —1 —. —1 < < <• 5* JD^ JD_ CD_ CD^ ^ •a -a -o ^ Ql D} fll EU 0) a- ;j g s- s- 3' 3 3' 3' 3' CQ (O (O CQ CO 5(? 2 II S Cl It g TJ 3. 01 I -• 8 ^ SD CD d CJ. CL O. T3 TJ TJ TJ T3 TJ m 01 01 Dl 01 01 s- s- s- s- s- s- 3" 5' 3' 3' 3' 3' S CO CO CO CO CQ Ul > o r m > I CO c 3 3 I O Tl 3 m r o • m z CO Fl 0) L Tl . r\ TITlTl-n-nTlTlC0T1T1T1TlTITlT1-nTl-nTlT!T]T1-nTlTlTlTl"nT13n<3 DJOODDTJTJTJDDooBaJODCDoooDDOODmooajosdoaicocococococAcocnrnSs Gjoocjcjon I G) Gi a a o Ci o Ci Q Ci o o a Ci o a o o Ci o o o s 30 m CO c 5 O-k-kNJONJOO —k_k_k(^C^.;^_k_k„j._k...k_k_k_k_k.k_k_k_k[SJ-k-*|\>-k_k^oNl~.^—kM .-^pSPP-*N:^PPPP)NJpp^pppppp7^ppopNjppop|Dgj^ CJltO(D4k.MCO-kOCOJk.Cj(D(Jl^C0004k.OO ooco-k-vicDoootocn e M 3 a S" I CDCDCDCDCDCDCD<OCDCDCDCDCDCDCDCDCOCO^<D(DCOCDCOCDCOCDCD<DCD ..^ "Q a><naiCA>cji->i^c«>oocji^aiM'*jaia)cnoio>ooo>oooa)cn*^aQCjicjia3^o»o S Q. (D r|o i a o 10 ~-k--k.kroNJM-k-k—k.k_k_k_k_k_k_k„k i^JlkrOMNJNJIONJNJ z P 6 1 O CO 6, CO i.' en CD CD sg CD 3 01 TJ 01 CO ffl eo z CO J^k OJ NJ. Tl Tl TJ DO o o Q. CX ffl ffl 3 3 O O ffl ffl cn cn 3 3 cn' M" 3- 3- •D CT Q) Q) < CO ffl ffl 3 CO 1^ CO CD 3 a Q. ffl o' 3 Tl p CO = C3 i Q) § I a 3 CO ffl ^ -I 3- a w ff -I -I (D ffl ffl DO ffl o" 3 CONJNJNJNJNJNJNJNJNJNJNJIOIONJNJNJNJNJNJNJNJNJNJNJIONININJNJ OC0(0C0cp(0(D(DC0(0C000Q9 00 00 p 00 00 0a 00 00-Nl'>J-.lvl-^->l-sl-v|'>J ocD09->jptnAtoNj-kocoo9-<iPtn--J>>CAlNJ-kOCOOO-.JPCn4kCONJ-k :^ 2) 5) 2j 24 s 5) NJ k k -A k k k 3 3 o o o O p o o o o o o o o (J) Ol (Jl Ol Ot p Ol CJl (Jl CD Ol Ol at Ol 21 ^^ 2J :y k —k k SS SS u SS SS o o o o o at CB at at Ol 2i :s N N k CO SS 3 o Ol at pa ii a a 3 3 i s o C 3- (Q CO CO CO CO CO 0 o o o o c c c c c 3 3 3 3 5 3 a d CJ. d (D 3. 3. 3 3 <5. < ? < CD EE. SE, SE. S. 3 TJ TJ TJ TJ 3 Dl 01 01 fll 01 3 3. -1 -I 3 S. S. Si 8 S (^ ^ ^ c c 3 3 g> g" g> S S g S °- 1 1 111 I d a o. CL 3. g. i- 3. 3 d d CD CD 3 3 3 3 S 8 d 3- SE. TJ TJ TJ 01 01 01 . . !"• ^ I" 3 3 3 CQ CD m <° <° <° ^ S SS. S. SE, SE. - - •§ ^ TJ TJ 01 g « § § § S z 2 g CD CD CD CD 2 - ft ft a a § d d d d d 3. 3. 3. 3. 3" < < < < ? SS. SD Sl SS. 5^ TJ TJ TJ p -o 01 01 01 U m a a E i: d a. 3. 3. < z m m i S ft d 3. 3. < I I IQ <o 3 3 3 3 3 CO CQ (5 (Q CO SE. _ TJ TJ TJ ^ 01 01 tt ^ s- s- a ^- 3 3 - 3 (Q CQ Tl Tl OD TJ Ci Q T1TlTl-nTIT|-nTl T3TJTIT3TITJTJTJ CiCiGiOCiOCiCi TiaTITl-nTITITlTlTl-nTlTITITI TJTJTJTJTJOOaJTJTITJTITJTJCDOD (DCJCJOGJOGJOOCnCiJOOCDO -n -n TJ 00 Ci Ci ml 3 I TiS 3 m 8 >< ° Bit b^bKjioAb+kbbp*.coMb-k-kcjb^ioloc*ioo"a>-kkib'o->i D » <•> I-l TJ 5. cn Ol -< O Tl Tl ili I-o a m Fl CO CO c r Si cn s fil 3 p. COCOCOCOCOCOCOCOPCOCOCDCOCOCOCOCDCOCOCPPCOCDCOCOCOCOCOCO oi--joicn-^ooc3ioo-.<oooicntntoo90iaj->ipp->i-^tn»tntntn~i'>i CO _ 00 o o 3 (D oa -kNJNJMNJNJNJNJNJNJNJMIOIOMrO-k-kMNJNJNJNJNJ-k-kMNJNJ-k il O Dl o 8: P o 3 CD eg. S» iS (» CO CD -J CD 00 cs I o 3 Dl ! s s ffl CO ^k OJ NJ , Tl Tl TJ DO O O CX Q. ffl ffl 3 3 O O ffl CO ffl CA Tl t J CO = ^ i % s i a 3 % ffi 3 3 3 ffl CO CA 3r 3- TJ cr QJ OJ < CO ffl ffl 3 CO % 3 a CX eo ® 3 a CX ffl o 3 -I ffl ffl ffl DO D> o 3 to to to CO to CAI 5 o o o o o cji tn .tk to NJ -k zS* pa 00 p go p •M 5j NJ NJ NJ ro NJ Ol NJ 9> 3 OJ i 3 (Jl 3 at g 3 o> CO CO CO CO TE S Q O > > > f f ^ E 3. 3. ;a 3. 50 ' 3 S d d d d TJ ,3 (»• a z p o •f e> cn ei Tl Tl Tl -n 3 T] CO CO CO CO DO CD O Ci Gl G) Gi O tn CJl ^ 00 CO tn -k K) p p p Ko 4>> ^ NJ 01 ^ CD CD CO CD CO CD -k NJ O Ol -vl CD CD CD CO CD (O ft NJ to cn X CD * a 13 * (Jl 3 tt TJ Q) CQ ffl Job No. 04-8756 TABLES LABORATORY COMPACTION TEST RESULTS (ASTM D15S7-91) Compaction Test Source of Maximum Optimum Dry Density Water Content Curve No. Description of Material Material (pcf) 1 SANDY CLAY (CL), Grayish Brown On-Site 123.0 11.0 2 SANDY CLAY (CL), Grayish Brown On-Site 125.0 10.5 3 WELL GRADED GRAVEL (GW), Gray, Class 2 base Import 121.0 13.0 4 SANDY CLAY (CL), Grayish Brown On-Site 126.5 10.2 5 SILTY SAND (SM), Reddish Brown Import 127.6 10.1 6 SILTY SAND (SM), Dark Brown Import 132.2 8.5 7 CLAYEY SAND (SC), Brown Import 130.0 9.0 8 CLAYEY SAND (SC), Olive Brown On-site 128.0 10.0 9 SILTY SAND (SM), Light Brown On-site 122.0 7.5 10 WELL GRADED GRAVEL (GW), Gray, Class 2 base Import 143.5 6.0 11 WELL GRADED GRAVEL (GW), Gray-brown Recycled Class 2 base Import 122.5 11.2 12 Asphalt Concrete HVEEM Import 146.0 Wasatch Commercial Management December 15,2011 RE: Joanne Franco, Property Manager To Whom it May Concem: This letter is to inform your company that Wasatch Commercial Management is the management company for several office buildings in Carlsbad, Califomia. The ownership entity of these office buildings are as follows: • Aviara Holdings, LLC • Palomar Heights Holdings, LLC • Wasatch Comerstone Holdings, LLC As the management company for the above entities, and in accordance with our management agreements, Wasatch Commercial Management, Inc. is authorized to sign on behalf of the owners for operational and capital related expenses. This letter authorizes Joanne Franco to sign on behalf of the above entities for operational and capital related expenses. Should you have any questions, do not hesitate to contact me on my direct line at (435) 755-2017. Regards, ^^^^ >^ •'f!^^*^/" Anita Lockhart Chief Operating Officer /al 595 South Riverwoods Parkway • Suite 400 • Logan • Utah • 84321 • (435) 755-2000 r > < > Jl > o g z o CO 8 z CO H 73 C o O BB I