HomeMy WebLinkAbout1002 Canvasback Ct; ; CB152407; PermitPrint Date: 06/28/2017 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 1002 Canvasback Ct BLDG-Residential 2146434300 $67,418.00 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit www.carlsbadca.gov Work Class: Addition Lot#: Reference #: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Status: Applied: Issued: Fina led: Inspector: Permit No: CB152407 Closed -Finaled 07/29/2015 09/19/2016 A Krog Description: RESDNTL-RAD MERLINO RES-423 SF ADD TO 2ND FLOOR, REMOVE EXISTING DECK AND REBUILD EXPANDED 428 SF DECK, ADD STAIRS TO ACCESS DECK Applicant: ANNIE MACIEL 7755 Fay Ave, Ste 1 La Jolla, CA 92037-4314 760-803-7805 Total Fees: Owner: TRUST MERLINO JOHN J JR&LISA M LIVING TRUST 11-09-07 1002 Canvasback Ct Carlsbad, CA 92011-3972 Total Payments To Date: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. (ci~of Carlsbad Bullcllntl Pennll Appllcatlon 1635 Faraday Ave., c.tsbad, CA 92008 Ph: ~2-2719 Fax: 760-602-8558 emal:bulldlngClcadsbadca.gov www.Cll'lllllldca.gov ·-1 oo 2. cA:.,Jv*" e,i.. G.t<. c. T • --- WORKERS COMPENSATION WorllwC t I I ..,..._,..,,, ...... ,,.,..al,,,..,_olfhtl ..... dadlnllllllls: IWPPP ZIP Z,.Otl ................. r1...-......... b ...... rmfll1'111111ll•pRlllldldllJSldiDII 3700afllelaborCadit, bllllt~al .. -'tbwbldllil pemilillelued. 01- ............ __. I l SI M1,•NlllilldbrSealiall3700allleUJbarCadt, far .. .,.__dh.-farllhlc:lllil~ililllal. ~llodrlrl' Cllril*llllffliMIDDGlllllrllldpaky -----Pdil:JNo. &l*lllanlllll _____ _ ]Mpdlllllllllllt•..,....flllltpllllllilb-hundnJddaln ($1CJO)ar• ~"~ ,.., .. _. .. ,._..a1u.11Glkbwllldlllispennltll--. I lllllnatallploy-,,.-. 1n..,w111•1Dbeea!NMjec:t1DlleWCIIIIII' (apnlllal1,... al Cllfamll. .... ,......... _.., ........................ ....,. ......................... _ ....... ._.. .... (&1t8.81, In ........... ,,11,,1 11, .......... llellllar ..................... .... A/S COJIIRACftlHGMTURE " 0AOSfl' ,,....., ..... , • .,._CGllndllr'l,...,LawAlrtlle~-0 ~ •_.d .. llJll!llltr,., ............ • llllrldac.a,flilllllan. llldo .. lllllklllll llellllan • natlnllndld arallnd b '* (Sc 7044, .._11111 f'nllllalllllCadl: The Calhdar'I U-.Lw .. Jl!t .. tWIJID•-•......,•lultl•lllpw.._,lildllhodolllUCll•hnlllarlnughNIGM1...-.PIIMdldllllllldl___...nnati.ndlldaralJndfar •it~---·• c lllallllllll-,-d~ .. -b1,..wlbMllellinllndp1111fngllllti.lldnatbulllarlmp,'Wb .. Pllpcilld'*). 0 ~--d .. $111$11111F, liil....., ..................... ID ...... Pft111Ct(Sc 7044 ......... PlofalllclltCadeclbeCcJl1adlJ'IUoael..wdom lllllllfllllYIIJ•-d pnlplllflll!ollulldt«illl!IIMt9-. and..._b'IUdl plljlcll wltOOMlll:lil(t) .._ puqunto .. Qlnllar's .___ t..). D ...... undllr88*11 .... Amallansc..rar11111-= 1., .......,.top,IM)ltlle_llbar ... ..-.farCGilllndJlld .. ,.....pnlpllt,...,._.. OV• C)*> 2.10-,•11111>*"'•.-.fllr•lddntl pn111r11tPRJ1101C1m 3.1'-0llllhcllllf11111Jt ......... (lnll)IDp1Mdl .. ,.....,.._..(lndDdl ..... -../plalalcanndanl' .... IIINIII): 4. l .... 1Dpnlllid9pllllanlctllt-lllltlhMhild ............ .,CGllilllllm. ................... (lndDdl .... , ..... ,fmll,c:ancbl' .... IUllber): 5. lwlprOllidl_d .. lllllk.lul-Gllllhrilld(lnd) ............. lopM!delll811Glklnlll*l(lndDdl11111111/ ..... /plala/t,pedlllllk): fil}f i:fOMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Cl Yes ~o Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Cl Yes yJ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Cl Yes '9No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I haw read the applicatlon and state that the above infonnation is conectand that the information on the plans is accurale. I agree ID comply with all City onlinances and State laws relallng ID buHclng construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned properly tir inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA pem11t is required for excavations over 5'0' deep and demolition or construction of sbuctures over 3 stories in height. EXPIRATION: Every pem11t issued by the Building · the provisiJns of this Code shall expire by imitation and be:;ome nuH and void ~ the building or v.ork authorized by such pem1it is not commenced wthin 180 days from the date of such pem11tor if the ilg orv.ork uch pem11t is suspended or abandoned at anytime after the v.ork is commenced for a period of 180 days (Section 106.4.4 Unii:>rm Building Code). ~ APPLICANT'S SIGNATURE DATE PERMIT INSPECTION HISTORY REPORT (CB152407) Permit Type: BLDG-Residential Application Date: 07/29/2015 Owner: TRUST MERLINO JOHN J JR&LISA M LIVING TRUST 11-09-07 Work Class: Addition Issue Date: 09/19/2016 Subdivision: Status: Closed -Finaled Expiration Date: 09/12/2017 Address: 1 002 Canvasback Ct Carlsbad, CA IVR Number: 708199 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete Checklist Item COMMENTS Passed BLDG-17 Interior Lath-Drywall Yes BLDG-18 Exterior Lath and Yes Drywall 06/22/2017 06/22/2017 BLDG-Final 026928-2017 Failed Andy Krogh Reinspection Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Green form and recycling form required No BLDG-Plumbing Final Yes BLDG-Structural Final Drywall required in closet under stairs No BLDG-Electrical Final Yes 06/28/2017 06/28/2017 BLDG-Final 027398-2017 Passed Paul Burnette Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Green form and recycling form required Yes BLDG-Plumbing Final Yes BLDG-Structural Final Drywall required in closet under stairs Yes BLDG-Electrical Final Yes June 28, 2017 Page 2 of 2 PERMIT INSPECTION HISTORY REPORT (CB152407) Permit Type: BLDG-Residential Application Date: 07/29/2015 Owner: TRUST MERLINO JOHN J JR&LISA M LIVING TRUST 11-09-07 Work Class: Addition Issue Date: 09/19/2016 Subdivision: Status: Closed -Finaled Expiration Date: 09/12/2017 Address: 1 002 Canvasback Ct Carlsbad, CA IVR Number: 708199 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date 11/08/2016 11/08/2016 BLDG-11 000242-2016 Passed Jonathan West Complete Foundation/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 12/06/2016 12/06/2016 BLDG-15 004233-2016 Passed Andy Krogh Complete Roof/ReRoof (Patio) 12/12/2016 12/12/2016 BLDG-13 Shear 005099-2016 Passed Andy Krogh Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency 4pc epoxy hold downs with special Yes inspection report 12/16/2016 12/16/2016 BLDG-13 Shear 005890-2016 Passed Andy Krogh Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Exterior deck sheeting Yes 02/01/2017 02/01/2017 BLDG-24 012068-2017 Partial Pass Andy Krogh Reinspection Incomplete Rough/Topout Checklist Item COMMENTS Passed BLDG-Building Deficiency Questions Yes 03/03/2017 03/03/2017 BLDG-14 015377-2017 Passed Andy Krogh Complete Frame/Steel/Bolting/ Welding (Decks) BLDG-84 Rough 015552-2017 Passed Andy Krogh Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 03/16/2017 03/16/2017 BLDG-82 Drywall, 016907-2017 Passed Andy Krogh Complete Exterior Lath, Gas Test, Hot Mop June 28, 2017 Page 1 of 2 CIRCUIT CARD B-36 Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov THIS CARD MUST BE FILLED OUT AND AVAILABLE AT THE SERVICE EQUJFMENT FOR THE ROUGH INSPECTION Address: lODZ. ~.J::-4 c.K.. CJ., Permit Number: Cl?:,/' Z 49! 0wner: ""4 ev-Ii,... n I Phone: Area in Sq. Ft. Jb:!:> Contractor: ~~4 ..,.,c0 "'-I Phone:,f.D 3lD '='"2.W PANEL: ... A.I.C. VOLTS 0 WIRE BKR WIRE LTG MISC WIRE BKR CKT LOCATION LOCATION CKT SIZE SIZE TYPE MISC REC REC SIZE TYPE SIZE •~•....c1e 1 (l.c) g ~ ~,../ 1.I. .4( 2 U,,. G.... 3 ,-c:: I'!-~'1 'i-$i:vS JI 4 f,..f-tO 5 If If ~ S"' 'S<:.> ~ g 6 IL, 7 I~ (4 ~ I 5'.> 2 8 IAl,.~\/j"· J.. 9 I c:;;.FJ. l't ~ t:: 10 ,,t,.. •u "· K.. 11 IS"A-n If../ <!.t.1 z 12 ,,,L~ Lj,,, ~ 13 1.>~t==J l4 <.: .... 4 "'.2.. 14 AJ.. ( ~I/. K. ,r J'f {'°sJ.S ~ tO 15 /')_,A 16 17 18 19 20 21 22 23 24 25 ~s:: '°' C Ii ,en 26 27 . --28 29 30 . -- 31 IVII (11; " c1 ~Ul/ 32 33 ··-· , ---34 35 I I \. JI \,;J-\j ;u::,tjALJ 36 ·'' Ill -,. ·~ - 37 ---11-,~ u, IVl0!' ,~ 38 39 40 41 42 MAIN:0 AMP BRK/FUSE O MLO Computed Load AMPS BUS; AMP See Calculalion Worksheet on back SelVice entrance or feeder conductors: Branch circuits required: A)Size: No. B)Type: 0 CU DAL A) Lighting Circuits 220 -3(b), 4(d) 8) Two Small Appliance Circuits 210-11(e) C) Insulation: D) Conduit Size: ___ C) Laundry Circuit 220 -16(b) Service ground/bond: D) Central Heating Equipment 422-12 A)Size: No. 8) Type: 0 cu O AL E} Bathroom 210-52(d) C) Clamp location(s): DUFER 250-50(c) Remarks: OWaterPipe 250-104 0 Ground Rod 250-52 0 GFCI locations 210 -8, 680 -70: I certify that all terminations have been torqued in accordance with manufacturer's D Bathroom(s) D Kitchen instructions and that the work shown on this circuit card represents the full extent of 0 Garage(s) OHydromassage Tub the work performed under this permit. 0 Ouldoors ;:J OOwner AFCI Protected Circ. 210-12 D Contractor 0 Bedroom(s) D Signed Date B-36 Page 1 of2 Rev. 03/09 Construction Testing & Engineering, Inc. Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying INSPECTION REPORT PAGE OF CTE JOB NO. 10 -'~'-\ 1 ~ PROJECT NAME ~ax,.........,__~( \_1 ~(\_6 __ 'Q_c;-,_\1~c_\~e_(\_(~Q- ADDRESS I ( ( :J ( ,, <W<,' 1b( 1' ( \c (' ~ (,,,, · 'n(,c\ C A INSPECTION 0 CONCRETE 0 REINF. STEEL REPORT NO. MATERIAL IDENTIFICATION CONG. MIX NO. & lb/in2 GROUT MIX NO. & lb/in2 ARCHITECT ?10iC' ~1o<'u, \ \x:'\r,\, / ~<<tf, D MASONRY MORTARTYPE&lb/in2 ' ENGINEER {'f'\c\C\ " <:.~l\1s..\.,uc,\ (1,, .. 11\\1 1o P.T.CONCRETE REINF.STEELGR./SIZE ____ _ CONTRACTOR fc:>,, c11..1 ) £•,....., fr, 1 1.. /, t • r -/ ,, r O FIELD WELDING STRUCTURAL STEEL OTHER INSPECTION DATE D SHOP WELDING HIGH-STRENGTH BOLT L.) n11 c:-:;-1< ' /?' I -:J/ 1 · I(.. 0 BATCH PLANT MASONRY BLOCK PLAN FILE/OTHER EXP.ANCHOR OTHER BLDG. PERMIT/OTHER OTHER f ~f'IXY MATERIAL SAMPLING D CONCRETE D MORTAR D GROUT 0 REINFORCING STEEL O STRUCTURAL STEEL 0 FIREPROOFING D BOLTS D 0 MASONRY BLOCK OTHER INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES. r:,J<r,. r,\H"'s:0(,(\ hr\-\ (?"""'YIE?r\c'E"'r\ \0 ,. \(\~ e,.. P'lt I ~ iA ~ f"nl\C"\(,:'~~ \"Ill -\V'IC (?()( "XI...\ vv,e-\\')c c\ \I IY'I~ ("I''"' P'' Y! Ce-\ ~? (£:'ll\? -=,/1~ \'i< \(( .(· r;• Q-;:>C ( 9\ OP < \ f\n S\ {A ~ ~\"e (('{ t"\P<" \10(.) ;::; (.tV (\: RECEIVED DEC 12 2016 CITY OF C4RLSBAO BUILDING DIVISION Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications. .. PRINTED NAME = CERTIFICATION NO. SIGNATURE ~/,M,~ & (;, ~ 1441 Montiel Road, Suite 115 I Escondido, CA92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net 0 C 111--C July 20, 2016 Tamara Fischer Esgil Corporation --------------------------------1-- MARTIN STRUCTURAL CONSUL TING, INC. 9320 Chesapeake Drive, Suite 208 San Diego, CA 92123 Subject: Soils at 1002 Canvasback Ct., Carlsbad, CA Dear Tamara: A test pit about 18" into grade was dug at the above address in the location where one of the proposed pad footings will be. The soil at the bottom of this pit appears to be adequately compacted and would fit in the class 5 category in the IBC table 1806.2. Although no testing of the soil has been done, it is my opinion that the soil would be adequate for the 1500 psf allowable bearing as given in the table. Please let me know if you have any questions or ifl can be of any further assistance. Sincerely, Tod D. Martin, S.E. 547 E. 6th Ave., Escondido, CA 92025 -Ph: ( 760) 74~012 -Fax: ( 760) 74~ tmartin-se@cox.net -http://martinstructuralconsulting.com m...-c July 20~ 2016 Tamara Fischer Esgil Corporation MARTIN STRUCTURAL CONSUL TING, INC. 9320 Chesapeake Drive, Suite 208 San Diego, CA 92123 Subject: Soils at I 002 Canvasback Ct., Carlsbad. CA Dear Tamara: RECEIVED ~::P I 9 2016 CITY OF CARLSBAD BUILDING DIVISION ~ A test pit about 18" into grade was dug at the above address in the location where one of the proposed pad footings will be. The soil at the bottom of this pit appears to be adequately compacted and would fit in the class 5 category in the IBC table 1806.2. Although no testing of the soil has been done, it is my opinion that the soil would be adequate for the 1500 psf allowable bearing as given in the table. Please let me know if you have any questions or if I can be of any further assistance. Sincerely, Tod D. Martin, S.E. 547 E. 6th Ave., Escondido, CA 92025 -Ph: { 760) 745-6012 -Fax: ( 7~ 745-6222 tmartin-se@cox.net -http://martinstructurak:onsulting.oom DATE: 9/15/16 JURISDICTION: Carlsbad PLAN CHECK NO.: 15-2407 EsGil Corporation In Cl'artnersliip witli qovernment for <BuiCaing Safety SET: IV PROJECT ADDRESS: 1002 Canvasback Ct. PROJECT NAME: Merlino Addition to SFR (With Revisions) \~ ~LICANT \,J""'"JUKIS. Cl PLAN REVIEWER Cl FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. C8J The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: C8J EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Teleph~----,1-: Date contact~ ~: !:} Email: Mail Telephone Fax Person {)tyl.:::J C8J REMARKS: 1) The red-clouded~ on sheets AS, A10 and S4 (upper left corner) need to be made on the City-held sel2)Applicant states that the City has approved the Engineer-of-Record's letter of visual inspection of the soils (rolled in plans) in lieu of a complete soil report for this project. Please verify. Thank you! ""0 '.~' ~ Q By: Tamara Fischer Enclosures: \..J'S, ~ EsGil Corporation 0 8() , Y\,C/j 0 GA O EJ O MB O PC 9/9/16 (/s s~ 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 -- EsGil Corporation In (l'artnersliip witli <]overnment for <BuiUing Safety DATE: 9/15/16 JURISDICTION: Carlsbad PLAN CHECK NO.: 15-2407 SET: IV PROJECT ADDRESS: 1002 Canvasback Ct. PROJECT NAME: Merlino Addition to SFR (With Revisions) \~ ~LICANT '\,,V"JUKIS. 0 PLAN REV IEWER 0 FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. ~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: T eleph~'lf: Date contact~ 'i: {y Email: Mail Telephone Fax Person {)t:fl.::J cg] REMARKS: 1) The red-clouded~ on sheets A8, A10 and S4 (upper left corner) need to be made on the City-held sel2)-Applicant states that the City has approved the Engineer-of-Record's letter of visual inspection of the soils (rolled in plans) in lieu of a complete soil report for this project. Please verify. Thank you! By: Tamara Fischer EsGil Corporation 0 GA D EJ D MB D PC Enclosures: 9/9/16 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1 468 + Fax (858) 560-1576 1-------- EsGil Corporation In g?artnersliip witli <;;overnment for (Bui(ain9 Safety DATE: 9/6/16 JURISDICTION: Carlsbad PLAN CHECK NO.: 15-2407 PROJECT ADDRESS: 1002 Canvasback Ct. SET: III PROJECT NAME: Merlino Addition to SFR (With Revisions) CJ~PPLICANT r!f JURIS. CJ PLAN REVIEWER CJ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. 1:8] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 1:8] The applicant's copy of the check list has been sent to: Annie Maciel, Professional Design and Drafting D EsGil Corporation staff did not advise the applicant that the plan check has been completed. 1:8] EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Annie Maciel, Professional Design and Drafting Telephone#: 760 803-7805 Date contacted: t\ 1~/l b (by: Jl(.) Email: amaciel@san.rr.com J'-"'Mail /Telephone V'tf\ Fax In Person 1:8] REMARKS: There are changes to the plans and a new designer. This is a new correction list and additional fees are required. By: Tamara Fischer EsGil Corporation D GA D EJ D MB D PC Enclosures: 8/30/16 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 -----------------~--- ·, Carlsbad 15-2407 9/6/16 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, ~~,~ineering and Fire Departments. 2. Bring fflO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • PLANS 1. Please see new policy above if plans are to be submitted to Esgil. 2. Indicate on the Title Sheet of the plans the name of the person responsible for the preparation of the plans. Section R 106.1.1. 3. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code. 4. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). Current structural plans and calculations are sealed and signed. This will be re-verified on the finals sets. 5. Please revise scope of work and demo plan to include removal and reconstruction of existing deck. 6. Please reference the cross section to the floor plan. 7. Site plan does not match the floor plan. (Existing deck to be re-built and extended, stair configuration, etc). Please coordinate. CONTINUED Carlsbad 15-2407 9/6/16 • FIRE PROTECTION 8. Please show a smoke alarm and carbon monoxide alarm in hallway outside bedroom 4 and a smoke alarm inside bedroom 4. Sections R314, R315. • GENERAL RESIDENTIAL REQUIREMENTS 9. Please clarify on the plans whether any existing windows are being altered (other than where new doors are being installed in living room, bath 4 and entry into new living area). For example, the size of bedroom 4 window and sidelites at door to side patio differ between the existing and proposed floor plans. If any other windows are being altered or replaced, please provide a key for window operation abbreviations (MU, SC, etc) so adequate emergency egress, light and ventilation, required safety glazing, fall protection, etc. may be verified in those rooms. • EXITS, STAIRWAYS, AND RAILINGS 10. Guards (Section R312): Please detail new interior guard (plans state to match existing, but it must be shown to comply with the current code) and exterior guards along stairs (structural detail does not match the architectural here) showing the following: a) Shall have a height of 42" (may be 34" along the sides of stairs). b) Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". c) Shall be detailed to show capability to resist a concentrated load of 200 pounds in any direction along the top rail. Table R301.5. 11. Handrails (Section R311.7.7): The handgrip portion of all handrails shall be not less than 1-'Xi inches nor more than 2 inches in cross-sectional dimension. See Section R311.7.8.3 for alternatives. • ROOFING 12. Please specify CertainTeed Asphalt Shingles for roof covering (The ICC approval number for this product (ESR1389) is listed on the plans). Section R106.1.1 • FOUNDATION /STRUCTURAL 13. Please verify with the City of Carlsbad that they will accept the Engineer-of- Record's letter of visual inspection of the soils in lieu of a complete soil investigation for this project. 14. Please show that there is adequate support for the east end of the catwalk framing. CONTINUED Carlsbad 15-2407 9/6/16 ------------·-- I 15. Please detail chimney extension. 16. Plans now show a new footing at the corner of the deck close to the pool. Please show that the pool wall will not be surcharged. 17. I see note 9 on sheet A-7, but it is not referenced at the dryer. Please show dryer vent and specify the discharge shall be minimum 3' from the openable window. 18. Please complete the attached Carlsbad Special inspection agreement. • RESIDENTIAL GREEN BUILDING STANDARDS Please add the following to Cal Green Notes 19. Storm water drainage/retention during construction. Note on the plans: Projects which disturb less than one acre of soil shall manage storm water drainage during construction by one of the following: A. Retention basins. B. Where storm water is conveyed to a public drainage system, water shall be filtered by use of a barrier system, wattle or other approved method. CGC 4.106.2. 20. Recycling. Note on the plans that a minimum of 50% of construction waste is to be recycled. CGC 4.408.1. 21. Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan to the jurisdiction agency that regulates waste management, per CGC 4.408.2. 22. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. • MECHANICAL I ELECTRICAL 23. Show that chimney shall extend at least 3' above the highest point where it passes through a roof and at least 2' higher than any portion of a building within a horizontal distance of 10 feet. CMC Section 802.5.4. I see the 2' higher than any portion within 10' called out at one chimney, but not the other and I do not see the 3' above the highest point where it passes through the new portion of roof called out for either chimney. CONTINUED Carlsbad 15-2407 9/6/16 • ENERGY CONSERVATION 24. Insulation notes on sheet A-3, A-10 and A-11 do not match the energy calcs. 25. Lighting installed in laundry rooms shall be high efficacy and be controlled by vacancy sensors. Please revise the note on sheet A 13. • MISCELLANEOUS • To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: • Yes CJ No CJ • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Tamara Fischer at EsGil Corporation. Thank you. Carlsbad 15-2407 9/6/16 ~CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT 8-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.catlsbadca.gov In accordance with Chapter 17 of the C!llifornia Building Code the following must be completed when work being performed requires sp.ecial inspection, structural observation and construction material testing. 'roject/Permit: __________ Project Address:. ________________ _ A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNERIAUTHORIZEO AGENT. Please check if you are Owner-Builder lJ. (If you checked as owner-builder you must also complete Section B of this agreement) Name: (Please print,___ _______________________________ _ {First) (M.I.) (Last) Mailing Addres~--------------------------------- Email._· -----------------------Phone_· _________ _ I am: OProperty Owner DProperty Owner's Agent of Record OArchitect of Record OEngineer of Record state of California Registration Numbe · Expiration Date: _______ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the state of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signatur.....__· ----------------------Date: ___________ _ B. C.ONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder I owner -builder. Contractor's Company Name: __________________ Please cheek if yoo are OWner-Builder a Name: (Please print) ________________________________ _ (Fir,;!) (M.!.) (Last) Mailing Address: _________________________________ _ Email: ________________________ Phone: __________ _ state of California Contractor's License Number: _________ Expiration Date: _______ _ • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have ih-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final report/ letter in compliance with CBC Section 1704.1.2 prior to requesting final inspection. Signature~: ______________________ Date: __________ _ B-45 Page 1 of 1 Rev. 08/11 Carlsbad 15-2407 9/6/16 [DO NOT PAY -THIS IS NOT AN INVOICE} VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 15-2407 PREPARED BY: Tamara Fischer DATE: 9/6/16 BUILDING ADDRESS: 1002 Canvasback Ct. BUILDING OCCUPANCY: R3 / U BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Revisions Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: D Complete Review D Repetitive Fee 3 Repeats * Based on hourly rate Comments: D Other 0 Hourly EsGil Fee Reg. VALUE Mod. D Structural Only ____ 2_.5--11 Hrs. @ • $100.00_ Sheet 1 of 1 ($) . I $312.501 $250.001 { ',i DATE: 2/4/16 JURISDICTION: Carlsbad 2-40::t- PLAN CHECK NO.: 15=264!1. EsGil Corporation In <Partnersliip witfi <;jo11emment for <Buiufing Safety SET: II PROJECT ADDRESS: 1002 Canvasback Ct. PROJECT NAME: Merlino Addition to SFR CJ .,APPLICANT ~ JURIS. CJ PLAN REVIEWER CJ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: David Belanich D EsGil Corporation staff did not advise the applicant that the plan check has been completed. ~ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: David Belanich Telephone#: 858 292-1414 .J.3-_ate contacted: 2--/ '.t\ (by}"L-1 Email: dbelanich@san.rr.com *>1ail ~e~ Fax In Person D REMARKS: By: Tamara Fischer EsGil Corporation D GA D EJ D MB D PC Enclosures: 1/28/16 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 15-2047 2/4/16 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. PLANS 1. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Current set is stamped and signed. This will be re-verified on final sets. EXITS, STAIRWAYS, AND RAILINGS 11. Please provide stairway and landing details. Section R311. 7. g) Show all stair and landing framing on the framing plan. (Including required support posts). Show all required footings for stair support on the foundation plan (it appears some are missing). I see footings have been shown at stairs, but most of the stair and landing framing has not been shown on the framing plan (stringers, landing joists, most support beams, posts, etc). 13. Handrails (Section R311.7.7): I do not see where the following items have been shown or noted on the plans. b) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. e) Ends of handrails shall be returned or shall have rounded terminations or ends. CONTINUED Carlsbad 15-2047 2/4/16 FOUNDATION /STRUCTURAL 19. Please provide a copy of the project soil report. All new residential buildings, including additions, require a soils report. An update letter is required if the report is more than 3 years old. Please note that this project does not comply with the exception for some additions since it is a second story addition. (There is an exception only if a room addition is less than 500 sq. ft. in area and only one story. The maximum allowable soil bearing value used in any design must be 1000 psf for this exception). It is a requirement of the City of the City of Carlsbad that a soil report (dated within the last 3 years) be provided for any second story addition. Please provide a soil report. 20. /fthe soils engineer recommends that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: a) The building pad was prepared in accordance with the soils report, b) The utility trenches have been properly backfilled and compacted, and c) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report." 21. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (if required by the soil report). 23. Please specify the depth below lowest adjacent grade at footing details on sheet A-7. Please specify the depth of footing at detail C/A7. 24. Please expand foundation plan to show all existing continuous and pad footings which are supporting new loads. Specify their width and depth below lowest adjacent grade. There is no footing shown below the bearing wall which supports new floor joists and point load from ridge beam above and the footings for existing deck posts (which are taking new loads) are not shown. 25. Please show location and sizes of all the existing headers, beams and posts below the new addition which support the new loads (including at deck extension). This has not been shown. 27 Clarify what is supporting the new catwalk joists at the east end. It appears a new beam may be required. This is still unclear. To what is the ledger connected? Please show all framing which supports the 2x12 ledger. CONTINUED Carlsbad 15-2047 2/4/16 28. Please provide and reference the following details: The following details need to be provided and referenced. a) Connection of the 4x12 deck beams to the cantilevered joists. b) Shear transfer from floor and roof diaphragms to shear walls at all conditions. c) Retrofit anchor bolts and hold downs. Likely to be required once lateral calculations are provided. d) Ledger attachments at all conditions. e) Extension of the chimney. 29. Please provide structural calculations by a licensed engineer or architect for the following: Structural calculations were not provided. Please provide them with the next submittal. a) New ridge beam spanning 15' above new bedroom. b) To justify that the existing footings are adequate to support the new plus existing loads. The allowable soil bearing value specified by the soil engineer may not be exceeded. c) To justify that existing headers, beams and posts are adequate for the new and existing loads. d) To justify the triple cantilevered joists supporting the 4x12 deck beams and the connection of the 4x12s to the cantilevered joist. e) For lateral loads at both levels, including the exterior wall lines at the addition and the interior wall lines between the addition and the existing house.(The plans do not comply with the conventional construction bracing provisions outlined in the CRC because of all the openings at both levels at the back exterior wall). f) For lateral loads at the deck and stairs (or provide and detail knee braces in both directions at each post). 31. Please complete the attached Carlsbad Special inspection agreement if special inspection is required (ie epoxy anchors for retrofit hold downs). MECHANICAL I ELECTRICAL 33. Show that chimney shall extend at least 3' above the highest point where it passes through a roof and at least 2' higher than any portion of a building within a horizontal distance of 10 feet. CMC Section 802.5.4. I see this shown for one chimney, but not the other. CONTINUED Carlsbad 15-2047 2/4/16 MISCELLANEOUS • To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: • Yes D No D • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Tamara Fischer at EsGil Corporation. Thank you. Carlsbad 15-2047 2/4/16 /\'~ ~-~·-·, ~ CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT 8-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special inspection, structural observation and construction material testing. 'roject/Permit: ___________ Project Address: _________________ _ A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder 1:1. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please print,__ _______________________________ _ (First) (Ml) (Last) Mailing Addres,,,.· ________________________________ _ Email_·-----------------------Phone· __________ _ I am: DProperty Owner DProperty Owner's Agent of Record DArchitect of Record DEngineer of Record State of California Registration Numbe · Expiration Date: _______ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signatur_· ______________________ Date: ___________ _ B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder I owner-builder. Contractor's Company Name: ____________________ Please check if you are Owner-Builder o Name: (Please print) ________________________________ _ (Ftrst} (Ml) (Last) Mailing Address: _________________________________ _ Email: ________________________ Phone: __________ _ State of California Contractor's License Number: __________ Expiration Date: ______ _ • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final report I letter in compliance with CBC Section 1704.1.2 prior to requesting final inspection. Signature~: ______________________ Date: __________ _ B-45 Page 1 of 1 Rev. 08/11 '' EsGil Corporation In Cl'artnersfiip witfi <;;overnment for <Bui{rfin9 Safety DATE: 8/13/15 JURISDICTION: Carlsbad PLAN CHECK NO.: 15-2047 2~0~ PROJECT ADDRESS: 1002 Canvasback Ct. PROJECT NAME: Merlino Addition to SFR SET: I ~~PLICANT ~JURIS. D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IZJ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IZJ The applicant's copy of the check list has been sent to: David Belanich D EsGil Corporation staff did not advise the applicant that the plan check has been completed. IZJ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: David Belanich Telephone#: 858 292-1414 _2:ate conJ?rcteda / ~ (byvA--Emai1: dbe1anich@san.rr.com c.{:,.Mail vf elephone Fax In Person D REMARKS: By: Tamara Fischer EsGil Corporation D GA D EJ D MB D PC Enclosures: 8/3/15 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 15-2047 ·8/13/15 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 15-2047 JURISDICTION: Carlsbad PROJECT ADDRESS: 1002 Canvasback Ct. FLOOR AREA: 384 sq ft SFD ADD 364 sq ft Deck/ Stairs REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 8/13/15 FOREWORD (PLEASE READ): STORIES: 2 HEIGHT: 25' approx per CRC DATE PLANS RECEIVED BY ESGIL CORPORATION: 8/3/15 PLAN REVIEWER: Tamara Fischer This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. .. Carlsbad 15-2047 8/13/15 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • PLANS 1. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Current set is stamped and signed. This will be re-verified on final sets. 2. Please specify the square footage of the deck and exterior stair additions under the Project data section on sheet A-1. 3. Please identify pool as existing on the site plan. 4. On the cover sheet of the plans, specify any items that will have a deferred submittal (fire sprinklers, if required). Additionally, provide the following note on the plans: "Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official." 5. Please provide exit alarms or other method of compliance with section 3109.4.4.2 for pool safety on new doors. CONTINUED Carlsbad 15-2047 8/13/15 • FIRE PROTECTION 6. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. 7. Show smoke alarms in the following existing and new areas. The smoke alarms shall be hard-wired and interconnected: Exception: Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R314 a) Inside each bedroom. b) Outside each separate sleeping area in the immediate vicinity of the bedrooms. c) On each story, including basements. 8. Specify on the plans that any existing smoke alarms that are more than 10 years old will be replaced. Section R314.3.2. 9. Show carbon monoxide alarms in the following existing and new areas. The carbon monoxide alarms shall be hard-wired and interconnected: Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315 a) Outside each separate sleeping area in the immediate vicinity of the bedrooms. b) On each story, including basements. CONTINUED Carlsbad 15-2047 8/13/15 • EXITS, STAIRWAYS, AND RAILINGS 10. Guards (Section R312): a) Provide a detail for the new portion of the interior guard at the upstairs hall and new catwalk. It must comply with the current code: i) Shall have a height of 42" (may be 34" along the sides of stairs). ii) Openings between railings shall be less than 4". iii) Shall be detailed to show capability to resist a concentrated load of 200 pounds in any direction along the top rail. Table R301.5. b) For the glass guard at deck (which does not have a top guard rail): (Section R312 and CBC section 2404.1). i) The minimum height is 42". ii) The glass guard must be laminated tempered glass or heat- strengthened glass of at least 2 plies of the same thickness and same glass type. iii) Provide complete structural calculations for the glass, base shoe and connection of the base shoe to the beam below. All must be capable of resisting a concentrated load of 200 pounds in any direction along the top with a factor of safety of 4 per Table R301.5 and section 2407 .1 CBC. 11. Please provide stairway and landing details. Section R311.7. a) Maximum rise is 7-3/4" and minimum run is 10", measured from the nosing projection. Where there is no nosing, the minimum run is 11 ". (Specify this at new interior steps up to bedroom as well). b) Minimum headroom is 6'-8". c) Minimum width is 36". d) The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. e) A nosing (between%" and 1-%") shall be provided on stairways with solid risers. Exception: No nosing is required if the tread depth is at least 11 inches. Section R311.7.5.3. f) Dimension each landing to be minimum 36" x 36". g) Show all stair and landing framing on the framing plan. (Including required support posts). Show all required footings for stair support on the foundation plan (it appears some are missing). 12. The walls and soffits of the enclosed usable space under stairs shall be protected on the enclosed side with %-inch gypsum board. Section R302.7. CONTINUED Carlsbad 15-2047 8/13/15 13. Handrails (Section R311.7.7): a) Shall be provided on at least one side of each stairway with four or more risers. b) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. c) The handgrip portion of all handrails shall be not less than 1-% inches nor more than 2 inches in cross-sectional dimension. See Section R311.7.8.3 for alternatives. d) Handrails projecting from walls shall have at least 1-% inches between the wall and the handrail. e) Ends of handrails shall be returned or shall have rounded terminations or bends. f) Please detail handrail attachment to glass guard. • GENERAL RESIDENTIAL REQUIREMENTS 14. Show that ceiling height for new bedroom and catwalk will be not less than 7 feet. Section R305.1 • ROOFING 15. Specify on the plans the following information for the waterproof deck covering per Section R 106.1.1. Must be Class A per City Ordinance: a) Manufacturer's name and product name/number. b) ICC approval number, or equal. 16. Specify minimum% inch per foot deck slope towards deck drain. Section R905.9.1. 17. Show the size/location of deck overflow drain. Section R903.4. • MASONRY 18. Please provide the manufacturer, product and ICC approval or equal for the adhered stone veneer. (If it is not adhered veneer, detailing on the plans is required to show compliance with the provisions of Section R703.7). CONTINUED Carlsbad 15-2047 8/13/15 • FOUNDATION /STRUCTURAL 19. Please provide a copy of the project soil report. All new residential buildings, including additions, require a soils report. An update letter is required if the report is more than 3 years old. Please note that this project does not comply with the exception for some additions since it is a second story addition. (There is an exception only if a room addition is less than 500 sq. ft. in area and only one story. The maximum allowable soil bearing value used in any design must be 1000 psf for this exception). 20. /fthe soils engineer recommends that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: a) The building pad was prepared in accordance with the soils report, b) The utility trenches have been properly backfilled and compacted, and c) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report." 21. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (if required by the soil report). 22. Please identify existing elements at detail A/A-7. 23. Please specify the depth below lowest adjacent grade at footing details on sheet A-7. 24. Please expand foundation plan to show all existing continuous and pad footings which are supporting new loads. Specify their width and depth below lowest adjacent grade. 25. Please show location and sizes of all the existing headers, beams and posts below the new addition which support the new loads (including at deck extension). 26. Show the post to support the ridge beam. 27. Clarify what is supporting the new catwalk joists at the east end. It appears a new beam may be required. CONTINUED Carlsbad 15-2047 8/13/15 28. Please provide and reference the following details: a) Connection of the 4x12 deck beams to the cantilevered joists. b) Shear transfer from floor and roof diaphragms to shear walls at all conditions. c) Retrofit anchor bolts and hold downs. d) Ledger attachments at all conditions. e) Extension of the chimney. f) Extension of the existing wall with a cripple wall above. g) The attachment of existing truss bottom chords to new floor joists (since the bottom chords are not likely to be able to span 15' on their own). 29. Please provide structural calculations by a licensed engineer or architect for the following: a) New ridge beam spanning 15' above new bedroom. b) To justify that the existing footings are adequate to support the new plus existing loads. The allowable soil bearing value specified by the soil engineer may not be exceeded. c) To justify that existing headers, beams and posts are adequate for the new and existing loads. d) To justify the triple cantilevered joists supporting the 4x12 deck beams and the connection of the 4x12s to the cantilevered joist. e) For lateral loads at both levels, including the exterior wall lines at the addition and the interior wall lines between the addition and the existing house.(The plans do not comply with the conventional construction bracing provisions outlined in the CRC because of all the openings at both levels at the back exterior wall). f) For lateral loads at the deck and stairs (or provide and detail knee braces in both directions at each post). 30. Nails for shear transfer connection (using A35's, etc.) may not be driven parallel to the flanges of T Jl's (i.e., along the sides), per city policy, unless specific written approval from Trus-Joist Macmillan is first obtained. Details or notes on the plans should make this clear. Nails may be driven perpendicular to T JI flanges. 31. Please complete the attached Carlsbad Special inspection agreement if special inspection is required (ie epoxy anchors for retrofit hold downs). • MECHANICAL I ELECTRICAL 32. It appears from the energy calcs that the existing FAU is to be used to heat the new bedroom. Please specify this on the plans and that existing ducts are to be extended. CONTINUED Carlsbad 15-2047 8/13/15 33. Show that chimney shall extend at least 3' above the highest point where it passes through a roof and at least 2' higher than any portion of a building within a horizontal distance of 10 feet. CMC Section 802.5.4. 34. Show on the plans receptacle outlets in the addition area located so as to comply with CEC Article 210.52. (In bedroom, at least one in new hallway (catwalk), and at least one exterior outlet at deck). 35. Include on the plans the following specifications for new electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). b) Weather resistant type for receptacles installed in damp or wet locations (outside). c) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.8(A): bedroom, hall d) GFCI protected outlets for locations described in NEC 210.8: (outdoors). 36. Show at least one wall switch-controlled lighting outlet to be installed in every habitable room; in bathrooms, hallways, stairways, attached garages, and detached garages with electric power; and at the exterior side of outdoor entrances or exits. At interior stairways show 3-way switching for lighting outlets at each floor level where there are six or more steps. CEC Article 210.70(A). For addition area. 37. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407. CONTINUED Carlsbad 15-2047 8/13/15 • RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the Green Building Standards Code which became effective January 1, 2011 and must be enforced by the local building official. The following mandatory requirements for residential construction must be included on your plans. CGC Section 101.3. The Standards apply to newly constructed residential buildings, along with additions/alterations that increase the building's conditioned area, volume or size. CGC Section 303.1.1. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. 38. Storm water drainage/retention during construction. Note on the plans: Projects which disturb less than one acre of soil shall manage storm water drainage during construction by one of the following: A. Retention basins. B. Where storm water is conveyed to a public drainage system, water shall be filtered by use of a barrier system, wattle or other approved method. CGC 4.106.2. 39. Grading and paving. Note on the plans that site grading or drainage system will manage all surface water flows to keep water from entering buildings (swales, water collection, French drains, etc.). CGC 4.106.3. Exception: Additions not altering the drainage path. 40. Note on the plans that when a shower is provided with multiple shower heads, 41. Recycling. Note on the plans that a minimum of 50% of construction waste is to be recycled. CGC 4.408.1. 42. Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan to the jurisdiction agency that regulates waste management, per CGC 4.408.2. 43. Operation and maintenance manual. Note on the plans that the builder is to provide an operation manual (containing information for maintaining appliances, etc.) for the owner at the time of final inspection. CGC 4.410.1. 44. Note on the plans that the gas fireplace(s) shall be a direct-vent sealed- combustion type. Woodstove or pellet stoves must be US EPA Phase II rated appliances. CGC 4.503.1. 45. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 4.504.1. CONTINUED Carlsbad 15-2047 8/13/15 46. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC 4.504.2. 47. Interior moisture control. Note on the plans that concrete slabs will be provided with a capillary break. CGC 4.505.2.1. 48. Interior moisture control. Note on the plans that the moisture content of wood shall not exceed 19% before it is enclosed in construction. The moisture content needs to be certified by one of 3 methods specified in Section 4.505.3. Building materials with visible signs of water damage should not be used in construction. The moisture content must be determined by the contractor by one of the methods listed in CGC 4.505.3. 49. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. • ENERGY CONSERVATION 50. "Compliance with the documentation requirements of the 2013 Energy Efficiency Standards is necessary for this project. Registered, signed, and dated copies of the appropriate CF1 R, CF2R, and CF3R forms shall be made available at necessary intervals for Building Inspector review. Final completed forms will be available for the building owner." 51. Regarding energy calcs (please revise to match plans): a) The energy calcs show that the new roof has a vented attic and has R38 insulation. the plans show a vaulted ceiling with 2x10 rafters (which won't fit R38) and section A/A7 shows R30 insulation. b) The section A/A7 shows R13 wall insulation, the energy calcs specify R15. c) The orientation used in the energy calcs appears to be incorrect. 52. Residential energy lighting requirements (Please note on the plans as applies for new light fixtures): ES 150.0(k) • High efficacy fixtures are required for bedroom, hall.etc or low efficacy fixtures are allowed if controlled by a dimmer or a vacancy sensor. • Outdoor lighting fixtures that are attached to a building are required to be high efficacy or be controlled by a combination photo-control/ motion sensor. CONTINUED Carlsbad 15-2047 8/13/15 • MISCELLANEOUS • To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: • Yes D No D • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Tamara Fischer at EsGil Corporation. Thank you. Carlsbad 15-2047 8/13/15 ,~?~'_-_: ~~:::i ~ CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT 8-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special inspection, structural observation and construction material testing. 'roject/Permit: ___________ Project Address: _________________ _ A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner.Builder CJ. (If you checked as owner-builder you must also complete Section B of this agreement) Name: (Please print,__ _______________________________ _ (First) (Ml.) (Last) Mailing Addres~--· --------------------------------- Email~·-----------------------Phone: __________ _ I am: OProperty Owner OProperty Owner's Agent of Record DArchitect of Record DEngineer of Record state of California Registration Numbe~·------------Expiration Date: _______ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the state of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signatur...._ ______________________ Date: ___________ _ B. CONTRACTOR'S ST A TEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder I owner-builder. Contractor's Company Name: ___________________ Please check if you are Owner-Builder o Name: (Please print) ________________________________ _ (First) (Ml) (Last) Mailing Address: _________________________________ _ Email: ________________________ Phone: __________ _ state of California Contractor's License Number: __________ Expiration Date: ______ _ • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final report I letter in compliance with CBC Section 1704.1.2 prior to requesting final inspection. Signature:~ ______________________ Date: __________ _ B-45 Page 1 of 1 Rev. 08/11 Carlsbad 15-2047 • 8/13/15 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 15-2047 PREPARED BY: Tamara Fischer DATE: 8/13/15 BUILDING ADDRESS: 1002 Canvasback Ct. BUILDING OCCUPANCY: R3 / U BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier SFD Add 384 157.88 Deck I Stairs 364 18.66 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance ~ Plan Check Fee by Ordinance • J Type of Review: 0 Complete Review D Repetitive Fee 3Repeats D Other D Hourly EsGil Fee Reg. VALUE Mod. D Structural Only i------1 Hr. @ • ($) 60,626 6,792 67,418 $480.841 $312.551 $269.271 Comments: In addition to the above fee, an additional fee of $43 is due (.5 hour@ $86/hr.) for the CalGreen review. Sheet 1 of 1 macvalue.doc + l._ City of Carlsbad PLAN CHECK REVIEW TRAN SM ITT AL Community & Economic Development Department 1635 Faraday Avenue Ca rlsbad CA 92008 www.carlsbadca.gov DATE: 08/05/2015 PROJECT NAME: MERLINO RESIDENTIAL ADDITION PROJECT ID:CB152407 APN: 2146434300 PLAN CHECK NO: 1 SET#: 1 ADDRESS: 1002 CANVASBACK CT VALUATION: $73,576 SCOPE OF WORK: 384 SF 2ND FLOOR ADDITION, 298 SF ADD TO 2ND FLOOR DECK, 66 SF STAIRCASE D This plan check review is complete and has been APPROVED by: LAND DEVELOPMENT ENGINEERING DIVISION Final Inspection by Construction Management & Inspection Division is required: Yes No X This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: DBELANICH@SAN.RR.COM To determine status by one of the divisions listed below, please contact 760-602-2719. Chris Sexton 760 602-4624 Gina Ruiz 760-602-4675 LAND DEVELOPMENT 760-602-2750 Chris Glassen 760-602-2784 Christopher.Glassen@carlsbadca.gov Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov ValRay Nelson 760-602-27 41 Va1Ray.Marshal1@carlsbadca.gov Greg Ryan 760-602-4663 Gregory.Ryari acarlsbadca.gov Cindy Wong 760-602-4662 C}'nthia.Wong carlsbadca gov Dominic Fieri 760-602-4664 Dominic.Fleri a:carlsbadca.gov Remarks : MERLINO RESIDENTIAL ADDITION PLAN CHECK NO# 1 N/A Outstanding issues are marked with X Items that conform to permit requirements are marked with I or have intentionally been left blank. 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: I North arrow I Existing & proposed structures ./ Existing street improvements ./ . Property lines (show all dimensions) Easements Right-of-way width & adjacent streets Show on site plan: Driveway widths Existing or proposed sewer lateral Existing or proposed water service Submit on signed approved plans: DWG No. Drainage patterns and proposed site elevations. Show all high points. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". Existing & proposed slopes and topography Size, location, alignment of existing or proposed sewer and water service(s) that serves the project Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: ./ Site address ./ Assessor's parcel number I Legal description/lot number For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. Show all existing use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. LoUMap No.: LTO 221 MAP 13988 Subdivision/Tract: CT 14-03 Reference No(s): E-36 Page 2 of 6 REV 6/01/12 - --------------I MERLINO RESIDENTIAL ADDITION PLAN CHECK NO# 1 N/A N/A N/A E-36 2. DISCRETIONARY APPROVAL COMPLIANCE Project does not comply with the following engineering conditions of approval for project no.: 3. DEDICATION REQUIREMENTS Dedication for all street rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 24 000 00 , pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: 4. IMPROVEMENT REQUIREMENTS All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $120,000.00, pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Construction of the public improvements must be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee, so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the city prior to issuance of a building permit. Future public improvements required as follows: Page 3 of 6 REV6/01/12 -------1-·--- MERLINO RESIDENTIAL ADDITION PLAN CHECK NO# 1 E-36 5. GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. If no grading is proposed write: "NO GRADING" Grading Permit required. NOTE: The grading permit must be issued and rough grading approval obtained prior to issuance of a building permit. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector The inspector will then provide the engineering counter with a release for the building permit. I No grading permit required. Minor Grading Permit required. See additional comments for project-specific requirements. 6. MISCELLANEOUS PERMITS RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work adjacent to the public right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-way permit required for: * NO WORK SHALL BE DONE WITHIN THE RIGHT OF WAY WITHOUT A PERMIT* Page 4 of 6 REV 6/01/12 MERLINO RESIDENTIAL ADDITION PLAN CHECK NO# 1 7. STORM WATER N/A BUILDING N/A BUILDING E-36 Construction Compliance Project Threat Assessment Form complete. Enclosed Project Threat Assessment Form incomplete. Requires Tier 1 Storm Water Pollution Prevention Plan (E-29). Please complete attached form and return (SW ) Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Development (SUSMP) Compliance Storm Water Standards Questionnaire. Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. Indicate areas of impervious surfaces (patios,walkway, etc. ) and pervious areas (landscaping). Project needs to incorporate low impact development strategies throughout in one or more of the following ways: Rainwater harvesting (rain barrels or cistern) Vegetated Roof Bio-retentions cell/rain garden Pervious pavemenUpavers Flow-through planter/vegetated or rock drip line Vegetated swales or rock infiltration swales Downspouts disconnect and discharge over landscape Other: Page 5 of 6 REV 6/01/12 MERLINO RESIDENTIAL ADDITION PLAN CHECK NO# 1 8. WATER METER REVIEW Domestic (potable) Use N/A UNDER 3400SF HABIT AL 9. FEES FYI FYI What size meter is required? Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size shall be a 1" meter. NOTE: the connection fee, SDCWA system capacity charge and the water treatment capacity charge will be based on the size of the meter necessary to meet the water use requirements. For residential units the minimum size meter shall be 5/8", except where the residential unit is larger than 3,500 square feet or on a lot larger than one quarter (1/4) acre where the meter size shall be%". Required fees have been entered in building permit. Drainage fee applicable Added square feet Added square footage in last two years? Permit No. Permit No. Project built after 1980 Impervious surface> 50% Impact unconstructed facility yes yes yes yes no no no no Fire sprinklers required Upgrade yes yes no (is addition over 150' from center line) no ./ No fees required 10. ADDITIONAL COMMENTS Attachments: Engineering Application Storm Water Form Right-of-Way Application/Info. Reference Documents E-36 Page 6 of 6 REV 6/01/12 1--- *** Fee Calculation Worksheet *** ENGINEERING DIVISION Prepared by: Date: GEO DATA: LFMZ: I B&T: Address: Bldg. Permit#: Fees Update by: Date: Fees Update by: Date: EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft/Units EDU's: Types of Use: Sq.Ft./Units EDU's: Types of Use: Types of Use: Sq.Ft./Units Sq.Ft./Units ADT CALCULATIONS: List types and square footages for all uses. EDU's: EDU's: Types of Use: Sq.Ft./Units ADT's: Types of Use: Types of Use: Types of Use: FEES REQUIRED: Sq.Ft./Units Sq. Ft./Units Sq.Ft./Units AD T's: ADT's: ADT's: Within CFO: YES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) NO 1. PARK-IN-LIEU FEE: NW QUADRANT NE QUADRANT SE QUADRANT ;W QUADRANT ADT'S/UNITS: I X FEE/ADT: I =$ 2.TRAFFIC IMPACT FEE: ADT'S/UNITS: I X 3. BRIDGE & THOROUGHFARE FEE: (USE SANDAG)ADT'S/UNITS I X FEE/ADT: DIST. #1 FEE/ADT: 4. FACILITIES MANAGEMENT FEE ZONE: ADT'S/UNITS: 5. SEWER FEE EDU's BENEFIT AREA: EDU's 6. DRAINAGE FEES: ACRES: 7. POTABLE WATER FEES: I X FEE/SQ.FT./UNIT: 1x FEE/EDU: 1x FEE/EDU: PLDA: HIGH 1x FEE/AC: I =s DIST.#2 I =s I =s I =s I =s MEDIUM I =s LOW UNITS CODE CONN. FEE METER FEE SDCWA FEE ***This may not represent a comprehensive list of fees due for this project. DIST.#3 TOTAL Please contact the Building division at (760) 602·2719 for a complete listing off ees*** «~~) ~ CITY Of CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 9/1/16 PROJECT NAME: ADDITION PROJECT ID: Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.e:ov PLAN CHECK NO: CB152407 SET#: ADDRESS: 1002 CANVASBACK CT APN: [8J This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required D Yes i:gi No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: AMACIEL@SAN.RR.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: ' ., ·, ,, .. '>t;,, · ·· > i, .P~NNlNA .·· . '76o=licf24610 ENGINSERING FIR~fJ!!'~itQN, 76Q-602·2l'SO ' D [8J D :.•, ., ' ·'<», c•,,, ',' Chris Sexton D Chris Glassen D Greg Ryan 76o-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov Christogher.Glassen@carlsbadca.gov Gregory. Ryan@carlsbadca.gov Gina Ruiz D ValRay Marshall D Cindy Wong 76o-602-4675 760-602-2741 760-602-4662 Gina.Ruiz@carlsbadca.gov Va1Ray.Marshall@carlsbadca.gov Cynthia.Wong@carlsbadca.gov D Linda Ontiveros D Dominic Fieri 760-602-2773 760-602-4664 Linda.Ontiveros@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: ZONED RDM-Q SETBACKS: FY=20'(20' REQ'D) ST SY=27'(10' REQ'D) IN SY=9'(5' REQ'D) RY=10'(10' REQ'D) COVER=43%(60% MAX) HEIGHT=24'(35' MAX) «~\ ~ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 8/3/15 PROJECT NAME: ADDITION PROJECT ID: Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.eov PLAN CHECK NO: CB152407 SET#: ADDRESS: 1002 CANVASBACK CT APN: ~ This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required D Yes 1:8'.1 No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: DBELANICH@SAN.RR.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: D ~ D .. PLJ\NNING ENGi.NEERiNG FIRE PREVENTION · : 760-602-4610 760-602-2750 760-6()2-4665 Chris Sexton Chris Glassen D Greg Ryan 760-602-4624 760-602-2784 760-602-4663 Chri~.S!:!xton~Q§!rlsbadQa.gQv ChristQPher.Glassen@carlsbadca_,ggv Gr~ory.,_R.yi!n@carlsbadca.gov Gina Ruiz D ValRay Marshall D Cindy Wong 760-602-4675 760-602-2741 760-602-4662 Gina.Ruiz@Qarlsb51dca.gov Va1Ray.Marshall@carlsbadca.gov Cynthia.Wong@carlsbadca.gov D Linda Ontiveros D Dominic Fieri 760-602-2773 760-602-4664 Linda.Ontiveros@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: ZONED RDM-Q SETBACKS: FY=20'(20' REQ'D) ST SY=27'(10' REQ'D) IN SY=9'(5' REQ'D) RY=10'(10' REQ'D) COVER=43%(60% MAX) HEIGHT=24'(35' MAX) Print Date: 06/29/2017 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 1002 Canvasback Ct BLDG-Permit Revision 2146434300 $ 0.00 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Permit Permit No: PREV2017-0022 www.carlsbadca.gov Work Class: Residential Permit Revisi Status: Completed 01/30/2017 02/28/2017 Lot#: Applied: Reference #: Issued: Construction Type: Finaled: Bathrooms: Orig. Plan Check#: Inspector: CB152407 A Krog Plan Check#: Description: MERLINO: MULTIPLE STRUCTURAL REVISIONS INCLUDING ADDITION OF EXTERIOR STAIRS // OMMISSION OF STRUCT BEAM// UPDATED FLOOR PLANS Applicant: ANNIE MACIEL 7755 Fay Ave, Ste 1 La Jolla, CA 92037-4314 760-803-7805 MANUAL BUILDING PERMIT FEE Total Fees: $ 187.50 Owner: TRUST MERLINO JOHN J JR&LISA M LIVING TRUST 11-09-07 1002 Canvasback Ct Carlsbad, CA 92011-3972 Total Payments To Date : $ 187.50 $187.50 Balance Due: $ 0.00 Ccityof Carlsbad PLAN CHECK REVISION APPLICATION 8-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Plan Check Revision No~,..) 2-ol 7 .-COZ?-original Plan Check No. C?:> \ S 2-" 'D 1 Project Address t00'2-C0--n vo..S\7uc1L C.-\-· Date 1 / 30 / ( r Contact (\ DYi \ e_ Ucx c( (:'_ \ Ph 7(QQ·-SO:/r SOS Fax Email G\ '(\'1_0 (:_ \ e__ l ~iu.V\' ( r .(C) W') Contact Address 11'5 S fu'-/ A.ve · Sui~ t~O t.,City \._o~ Jo1l°' L~ip qg_ o~ f General Scope of Work (k_m()c},e_ \ Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: Plans [tl Calculations D Soils D Energy D Other 2. Describe revisions in detail 3. List page(s) where each revision is shown 5 (,;, -'k_\llS-e°' T-a C\t\Q./v\C\,e.6 +:? r-e v_c an -aY'-~~~ • Does this revision, in any way, a1ter the ex enor of the project? ~ 6. Does this revision ad ANY new floor area{s)7 t'7!Yes n No ~ \And-€-\ s-\-ct~ 7. Does this revision a ct any fire related issues? D Yes ~ No 8. 4. List revised sheets that replace existin sheets A-~ I ~-) () r.\-8 rt~,-~-\\ A-,3 -A-I b 0No ft!: 7 60-602-719 fax: 7 60-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov DATE: 2/27/17 JURISDICTION: Carlsbad EsGil Corporation In (l'artnersliip witli government for <Builain9 Safety PLAN CHECK NO.: PREV2017-0022 (15-2407) SET: II PROJECT ADDRESS: 1002 Canvasback Ct. PROJECT NAME: Merlino Addition to SFR ~ ~LICANT ~RIS. 0 PLAN REVIEWER 0 FILE D The, plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. .. ~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Annie Maciel D EsGil Corporation staff did not advise the applicant that the plan check has been completed. t:8J EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Lisa Merlino (Owner called to check status).Telephone #: 760 918-2440 Mail xTelephone Fax In Person ~ REMARKS: 1) The red-clouded change at the upper left corner of sheet S4 needs to be made on the City-held sets. (This was a counter correction from the originally approved plans). 2) Revision Set II was an incomplete set. It needs to be slip-sheeted into Revision Set I to make a complete, approved, revised set. I have slip-sheeted this set. Thank you. By: Tamara Fischer EsGil Corporation D GA D EJ O MB D PC Enclosures: 2/21/17 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 DATE: 2/6/17 JURISDICTION: Carlsbad EsGil Corporation In <Partnersliip witli <]01Jemment for <Bui{aing Safety PLAN CHECK NO.: PREV2017-0022 (15-2407) SET: I PROJECT ADDRESS: 1002 Canvasback Ct. PROJECT NAME: Merlino Addition to SFR D_ftPLICANT ~ :~RIS. D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Annie Maciel D EsGil Corporation staff did not advise the applicant that the plan check has been completed. ~ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Annie M~if) Telephone#: 760 803-7805 Date contacted: 1,-,,,(.e (b~ ) Email: amaciel@san.rr.com Q.Mail")( Telepho1" ~ Fax In Person D REMARKS: By: Tamara Fischer EsGil Corporation D GA D EJ D MB D PC Enclosures: 1/31/17 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 15-2407 2/6/17 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: PREV2017-0022 (15-2407) JURISDICTION: Carlsbad PROJECT ADDRESS: 1002 Canvasback Ct. REVISIONS TO: FLOOR AREA: 384 sq ft SFD ADD STORIES: 2 364 sq ft Deck / Stairs REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 2/6/17 FOREWORD (PLEASE READ): HEIGHT: 25' approx per CRC DATE PLANS RECEIVED BY ESGIL CORPORATION: 1/31/17 PLAN REVIEWER: Tamara Fischer This revision plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. ., Carlsbad 15-2407 2/6/17 • PLANS • Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Please update expiration date on engineer's seals on plans and calcs. 2. Red-clouded counter corrections from the originally approved plans need to be transferred to the revised set. 3. Please revise calculations for beam 8-1. The load has increased due to the reduction of the number of beams. Also, these beams are not fully laterally braced. 4. The upper wall at gridline A is now being altered, with possible reduction in shear wall length. Please address lateral loads here in the structural design. MISCELLANEOUS • To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes O No O • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Tamara Fischer at EsGil Corporation. Thank you. f Carlsbad 15-2407 2/6/17 {DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: PREV2017-0022 (15-2407) PREPARED BY: Tamara Fischer DATE: 2/6/17 BUILDING ADDRESS: 1002 Canvasback Ct. BUILDING OCCUPANCY: R3 / U BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Revisions Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: D Complete Review D Repetitive Fee Repeats • Based on hourly rate Comments: D Other 0 Hourly EsGil Fee Reg. VALUE Mod. D Structural Only 1.5 Hrs.@* ...._ ___ ...... $100.00 ($) s1a1.sol $150.001 Sheet 1 of 1 macvalue.doc +