HomeMy WebLinkAbout1004 CANVASBACK CT; ; CB110879; Permit04-27-2011
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Cogeneration Permit Permit No:CB110879
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
1004 CANVASBACK CT CBAD
COGEN Sub Type: EVG
2146434200 Lot#: 0
$0.00 Construction Type: NEW
Reference #:
SMITH RES- INSTALL 40A CIRCUIT
& NEMA 6-50 RECEPTACLE FOR EV EQUIPMENT
Applicant:
SUNWEST ELECTRIC INC
3064 E MIRALOMA AV 92806
714630-8700
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
Owner:
SMITH KENNETH B&BRIDGET A
1004 CANVASBACK CT
CARLSBAD CA 92011
ISSUED
04/27/2011
LSM
04/27/2011
04/27/2011
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Green Bldg Stands (SB1473) Fee
Total Fees: $22.00 Total
$0.00
$20.00
$0.00
$0.00
$0.00
$1.00
$1.00
Payments To Date:
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Additional Fees
TOTAL PERMIT FEES
$22.00 Balance Due:
$0.00
$0.00
$0.00
$0.00
$22.00
$0.00
Inspector:
FINAL APPROVAL
Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
CITY OF
CARLSBAD
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
760-602-2717 / 2718 / 2719
Fax 760-602-8558
www.carlsbadca.gov
Plan Check No. Q&\\
Est. Value
Plan Ck. Deposit
SWPPP
JOB ADDRESS 1004 CANVASBACK STREET-
CT/PROJECT #PHASE* |#OFIMTS I#BEDROOMS
SUITE#/SPACE#/UNIT#
LOT#ft BATHROOMS 1 TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
Install 40A circuit and NEMA 6-50 receptacle for Electrical Vehicle Equipment
EXISTING USE PROPOSED USE GARAGE (SF)
300
PATIOS (SF)DECKS (SF)FIREPLACE
NCT~I
AIR CONDITIONING
YES | |NO I I
FIRE SPRINKLERS
CONTACT NAME (If Different Font Applicant)APPLICANT NAME Shaun Eastman
ADDRESS ADDRESS
3064 E. Miraloma Ave.
CITY STATE ZIP CITY
Anaheim
STATE
CA
ZIP
92806
PHONE FAX PHONE
714-678-0083
FAX
714-630-8740
EMAIL EMAIL
seastman@sunwestelect.com
PROPERTY OWNER NAME KEN SMITH CONTRACTOR BUS. NAME Sunwest Electric, Inc.
ADDRESS
1004 CANVASBACK ST.
ADDRESS
3064 E. Miraloma Ave.
CITY
Carlsbad
STATE
CA
ZIP
92011
CITY
Anaheim
STATE
CA
ZIP
92806
PHONE
858-583-2115
FAX PHONE
714-60-8700
FAX
714-630-8740
EMAIL EMAIL
seastman@sunwestelect.com
ARCH/DESIGNER NAME & ADDRESS STATE LIC. #
511697
CLASS
CIO
CITY BUS. LIC.#
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapppcant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500)).
: I certify that in the performance of the work for which this permit is issued, I shall not e f any person in any manner so as to become subject to the Workers' Compensation Laws of
tflpyerto criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
\ 11 have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700.fif the Labor Code, for the performance of the work for which this permit is issued.
1/J I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance/of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co old Republic insurance Corp pofcy No / /Vicw4ii2iou3 Expiration Date .
This section need not be completed if the permit is for one hundred dollars ($100) or less.
[ | Certificate of Exemption: I
California. WARNING: Failure to secure workers' compensation coverage is unlawful, an
addition to the cost of compen
J&$ CONTRACTOR SIGNATURE
/ hereby affirm that I am exempt from Contractor's License Law for the following reason:
| | I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I/I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law).
| [ I am exempt under Section Business and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. I lYes I JNo
2.1 (have / have not) signed an application for a building permit for the proposed work.
3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number):
4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number):
5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work):
.^PROPERTY OWNER SIGNATURE 0AGENT DATE
Is the applicant or future building occupant required to submit a business clan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? | |Yes I iNo
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or ainjuality management district? I lyes I I No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? I lYes l~nNo
CY MAY NOT BE ISSUED I
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address n/a
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purf
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINSTjE
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 s
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation i
180 days from the date of such peiajtpr if Uie-bttMBg-eumrk authorized by s
^APPLICANT'S SIGNATUK
f\ ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
JD CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
> in height
i null and void if the building or work authorized by such permit is not commenced within
(trie after the work is commenced for a oeriod of 180 days (Section 106.4.4 Uniform Building Code).
t/_
DATE
City of Carlsbad Bldg Inspection Request
For: 05/19/2011
Permit* CB110879
Title: SMITH RES- INSTALL 40A CIRCUIT
Inspector Assignment:
Description: & NEMA 6-50 RECEPTACLE FOR EV EQUIPMENT
NO NEW METER/ NO PANEL UPGRADE/ EQUIP IN
f+ A n A f+tz
Type:COGEN Sub Type: EVG
Job Address: 1004 CANVASBACK CT
Suite: Lot: 0
Location:
APPLICANT SUNWEST ELECTRIC INC
Owner: SMITH KENNETH B&BRIDGET A
Remarks: car charger inspection
Phone: 7143157753
Inspect
Total Time:
CD Description
39 Final Electrical
Act Comments
Requested By: CARLOS
Entered By: CHRISTINE
I(Jo M
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
Inspection History
Date Description Act Insp Comments
LUi
LULJJ
C/)
%T>\ x «u \s\ <<* >. e.\ *4»
^ "o o^
^ -£> 4
• •>
o
o
UJCO
UJo
a:
UJ_i
z>o CM
O
CM
i— >.
P U-;
CCL
5 > ^09 °
LU
LLJO
LUCO
o
Q-oa
I'
UJC)
o
LLJ UJ
\-/ "3 ^co < r-
GENERAL NOTES & SPECIFICATIONS (SHEET 1 OF 2)
WORK SPECIFIED HEREIN
WORK UNDER THIS SPECIFICATION INCLUDES FURNISHING ALL MATERIAL,
LABOR, EQUIPMENT, ETC., AND FINAL CONNECTION TO EQUIPMENT IN ORDER
TO PROVIDE THE OWNER WITH A COMPLETE AND PROPERLY FUNCTIONAL
ELECTRIC VEHICLE SUPPLY EQUIPMENT. IN GENERAL, THE WORK SHALL
CONSIST OF BUT NOT BE LIMITED TO THE FOLLOWING:
• FURNISH AND INSTALL ALL OF THE EQUIPMENT AND THE POWER SUPPLY
FOR THE ELECTRIC VEHICLE SUPPLY EQUIPMENT, INCLUDING; CIRCUIT
PROTECTION DEVICES AND BRANCH FEEDERS.
• PRIOR TO INSTALLATION AND FINAL CONNECTION, VERIFY ELECTRICAL
CHARACTERISTICS OF THE DISTRIBUTION SYSTEM AND LOCATION OF THE
EVSE,
• GROUT AND SEAL ALL CONDUIT PENETRATIONS OF WALLS AND ROOF TO
MAINTAIN FIRE RATING AND WATERTIGHT INTEGRITY OF WALLS AND ROOF.
GENERAL REQUIREMENTS
THE CONTRACTOR WILL BE HELD TO HAVE THOROUGHLY REVIEWED GENERAL
CONSTRUCTION DRAWINGS. EXAMINED THE SITE. PREMISES AND SATISFIED
HIMSELF AS TO EXISTING CONDITIONS UNDER WHICH HE WILL BE OBLIGED TO
OPERATE OR WHICH WILL IN ANY MANNER AFFECT THE WORK UNDER THIS
CONTRACT. NO SUBSEQUENT ALLOWANCE WILL BE MADE IN BEHALF OF THE
CONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART. PROVIDE
STANDARD PRODUCTS OF ESTABLISHED MANUFACTURERS REGULARLY
ENGAGED IN THE PRODUCTION OF SUCH EQUIPMENT. PROVIDE NEW MATERIAL.
APPARATUS AND EQUIPMENT OF THE BEST PRACTICE OF THE ELECTRICAL
TRADE AND BY SKILLED CRAFTSMEN. ALL EQUIPMENT SHALL BE LISTED BY
UNDERWRITERS LABORATORIES, OR EQUIVALENT NRTL, FOR USE INTENDED.
THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND THE CONTRACTOR SHALL
HARMONIZE HIS WORK SO THAT EACH PIECE OF EQUIPMENT WILL BE
INSTALLED SO AS TO FUNCTION PROPERLY. COOPERATE WITH OWNER AND
VERIFY ALL EQUIPMENT LOCATIONS. WORK SHALL BE PERFORMED IN
ACCORDANCE WITH ALL ORDINANCES AND REGULATIONS OF STATE, COUNTY,
MUNICIPAL AUTHORITIES. UTILITY COMPANY, N.E.C. AS SHOWN ON
CONSTRUCTION DOCUMENTS.
SEE CONSTRUCTION DRAWINGS FOR EQUIPMENT LOCATIONS. AND APPLICABLE
ELEVATIONS AND DETAILS. ELECTRICAL CONTRACTOR TO VERIFY AND
ACKNOWLEDGE ALL CODES AND REGULATIONS PERTAINING TO THIS PROJECT.
REFER TO THE NATIONAL ELECTRIC CODE, ARTICLE 625 AND ALL OTHER
APPLICABLE SECTIONS OF THE NEC,
CONDUITS SHALL BE SIZED IN ACCORDANCE WITH THE APPROPRIATE TABLE
OF NEC, AND SHALL BE OF SUCH SIZE AND SO INSTALLED THAT
CONDUCTORS MAY BE DRAWN IN WITHOUT INJURY OR STRAIN. CONDUIT
SHALL BE SECURED TO PULL BOXES, SUPPORT BOXES, OR OUTLET BOXES
WITH GALVANIZED LOCKNUTS AND BUSHINGS. ALL CONDUITS SHALL BE RUN
CONCEALED PRINCIPALLY IN OVERHEAD AND WALL CONSTRUCTION.
ALL CONDUIT THAT MUST BE EXPOSED SHALL BE RUN PARALLEL WITH LINES
OF THE BUILDING. CHASES AND OPENINGS IN WALLS, PARTITIONS AND
FLOORS SHALL BE PROVIDED FOR INSTALLATION OF CONDUIT; ALL
CONCEALED WORK SHALL BE DONE SO AS TO MINIMIZE CUTTING AND
PATCHING.
ALL CONDUIT NOT EMBEDDED IN CONCRETE SHALL BE FIRMLY SECURED BY
LISTED PIPE CLAMPS, HANGERS. ETC.
ELECTRICAL METALLIC TUBING: USED FOR ALL WIRING EXCEPT IN OR UNDER
CONCRETE, EARTH, FILL, OR GROUTED BLOCK WALLS.
GALVANIZED STEEL CONDUIT: USED FOR ALL WIRING IN OR UNDER
CONCRETE. EARTH, FILL AND GROUTED WALLS. IN EARTH OR FILL. COAT WITH
POLYETHYLENE TAPE. SPIRAL WRAPPED TO NOT LESS THAN 40MILS.
NON-METALLIC: LISTED. SCHEDULE 40, PVC MAY BE USED FOR BRANCH
FEEDER CIRCUITS IF RUN UNDER CONCRETE FLOOR. PROVIDE BONO WIRE PER
NEC. PVC CONDUIT SHALL BE BURIED MINIMUM OF 24 INCHES IF NOT
INSTALLED UNDER CONCRETE OR ENCASED IN 3 INCH CONCRETE ENVELOPE,
FLEXIBLE METALLIC CONDUIT OR METAL-CLAD CABLE: MAY BE USED FOR
SHORT FINAL CONNECTIONS FOR INDOOR EQUIPMENT. PROVIDE INSULATED
COPPER BOND WIRE IN ALL FLEXIBLE RACEWAYS AND SIZED PER NEC- 250.
LIQUIDTIGHT FLEXIBLE METALIC CONDUIT: SHALL BE USED OUTDOOR AND IN
MOIST LOCATIONS WITH LISTED TERMINATION FITTINGS.
*•* V* gm. . . 430 S SECOND AVE. PROJECTSPM f*mi£*rt PHOENIX, AZ 85003^*»nWJO>»l TEL: 602-345-9006
APPROVALS DATE PROJECT
DRAWN
CHECKED
ENGINEER
ALL CONDUCTORS SHALL BE SOFT DRAWN ANNEALED COPPER HAVING
PURE COPPER CONDUCTIVITY OF NOT LESS THAN 9SZ. UNIFORM IN
CROSS SECTION,
FREE FROM FLAWS. SCALES, AND OTHER IMPERFECTIONS.
CONDUCTORS IN CONDUIT:
•XHHW-2 OR THWN-2 INSULATION FOR ALL EXTERIOR FEEDERS IN
CONDUIT,
•THHN-2 INSULATION FOR ALL INDOOR BRANCH CIRCUITS IN CONDUIT.
•MINIMUM SIZE WIRE SHALL BE #14 AWG COPPER.
•NO WIRE MAY BE DRAWN INTO CONDUIT UNTIL CONDUIT SYSTEM IS
COMPLETE. CONDUCTOR PULLING LUBRICANT SHALL BE USED TO
FACILITATE WIRE PULLING.
NONMETALLIC-SHEATHED CABLE:
NON-METALLIC SHEATHED CABLES SIZED PER NEC MAY PROVIDE ALL
WIRING CONNECTIONS FOR EQUIPMENT FURNISHED UNDER OTHER
SECTIONS OF THE SPECIFICATIONS
ALL WIRING SHALL BE TESTED UPON COMPLETION OF WORK. AND
ADJUSTMENTS MADE NECESSARY FOR SATISFACTORY OPERATION OF THE
SYSTEM.
WHERE SUBJECT TO PHYSICAL DAMAGE. CONDUCTORS SHALL BE
ADEQUATELY PROTECTED. WHEN THE WIRING METHOD IS INSTALLED
THROUGH BORED HOLES
IN JOISTS. RAFTERS OR WOOD MEMBERS, HOLES SHALL BE BORED SO
THAT THE EDGE OF THE HOLE IS NOT LESS THAN 1-1/4" FROM THE
NEAREST EDGE OF THE WOOD MEMBER. WHERE THIS DISTANCE CANNOT
BE MAINTAINED, THE CABLE SHALL BE PROTECTED FROM PENETRATION
BY SCREWS OR NAILS BY A STEEL PLATE. AT LEAST 1/16" THICK. AND
OF APPROPRIATE LENGTH AND WIDTH INSTALLED TO COVER THE AREA OF
THE WIRING.
•GROUNDING CONDUCTORS:
ALL GROUND CONDUCTORS SHALL BE SIZED PER NEC 250 PER EACH
APPLICATION.
NAUE: KEN SMITH
ADDRESS 1Q04 CANVASBACK ST.
CALABASES.CA 92011
M.G.R.
REV. - - SIZE
PROJECT 1 A
DO NOT SCALE DRAWINGS SCALE
CODE INTENT NO. DWG NO.
NA | SHEET _ OF
GENERAL NOTES & SPECIFICATIONS (SHEET 2 OF 2)
SAFETY SWITCHES
SAFETY SWITCHES, SHALL BE HEAVY DUTY TYPE, 240 VOLT MINIMUM
WITH THE EXACT NUMBER OF POLES REQUIRED. ALL SAFETY SWITCHES
SHALL BE OF THE FUSIBLE TYPE, FUSES SHALL BE SIZED AS
RECOMMENDED BY EQUIPMENT MANUFACTURER, THE SWITCH SIZE SHALL
BE AS REQUIRED BY THE NEC AND AS INDICATED ON THE DRAWINGS
AND SIZED PER HORSEPOWER RATING. WHERE OUTSIDE THE BUILDING,
THE SWITCHES SHALL BE RAINTIGHT TYPE NEMA-3R.
FUSES
FUSES SHALL BE OF THE TYPE, SIZE AND RATING AS INDICATED ON
THE DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ENGINEER ON RECORD FOR RESOLUTION.
GROUNDING
ELECTRICAL CONTRACTOR SHALL VERIFY PROPER GROUNDING
CONNECTIONS, GROUND CONDUCTORS AND INSTALL AS PER THE
GROUNDING DETAILS AS INDICATED IN THESE DRAWINGS. ALL EQUIPMENT
AND ENCLOSURES, AND THE COMPLETE CONDUIT SYSTEM SHALL BE
GROUNDED SECURELY IN ACCORDANCE WITH PERTINENT SECTIONS OF
NEC, ARTICLE 250. ALL ELECTRICALLY OPERATED EQUIPMENT SHALL BE
BONDED TO THE GROUNDING SYSTEM. ANY DISCREPANCIES SHALL BE
BROUGHT TO THE ENGINEER ON RECORD FOR RESOLUTION.
BRANCH PANELS
BRANCH PANELBOARDS ARE EXISTING AND SHALL BE USED. BREAKER
TYPE SHALL BE MATCHED WITH THE EXISTING AND RATED AS SPECIFIED
ON THE DRAWINGS. TIE BARS TO FORM TWO-POLE BREAKERS WILL NOT
BE ACCEPTED. EACH PANEL SHALL BE PROVIDED WITH A TYPEWRITTEN
SHEET INSTALLED ON THE DOOR, WHICH IDENTIFY THE ASSIGNMENT OF
EACH BREAKER.
FINAL INSPECTION & TESTS
FURNISH ALL METERS, CABLE CONNECTIONS AND APPARATUS
NECESSARY FOR TESTING. TEST SYSTEM FOR SHORTS AND GROUNDS.
FAULTY WIRING SHALL BE REMOVED AND REPLACED. ANY DEVICE,
APPARATUS OR FIXTURE INSTALLED SHOWING SUB-STANDARD
PERFORMANCE SHALL BE REMOVED AND REPLACED AT NO ADDITIONAL
COST TO THE OWNER.
FIELD NOTES
^Project 430 S SECOND AVE.
PHOENIX. AZ 85003TEL: 602-3+5-9006
APPROVALS
DRAWN
CHECKED
ENGINEER
M.G.R.
REV.
PROJECT # _
DO NOT SCALE DRAWINGS
PROJECT NAME:KEN SMITH
PROJECT ADDRESS:1004CANVASBACKST.
CALABASES, CA 92011
SIZE
A
CODE INTENT NO.DWG NO.
SCALE NA SHEET OF
SMITH / SDR-0797
RESIDENTIAL LOAD CALCULATION
PANEL TYPE : CUTLER
MAIN CB AMPS: 200
General Lighting and receptacle loads :: :!l I
NEC 2008- 220.83 (A)(1) |
Outside dimensions of home (exclude garage)
Small appliance and laundry load j
NEC 2008-!220;83 (A)(2) |
Small appliance
Laundry
special ftppiiance Loaas I
NEC2008^220.83(A)(3) |Phas
Dishwasher 1
Disposal 1
Microwave 1
Exhaust Hood 1
Refrigerator 1
Trash Compactor 1
Clothes Dryer ( electric ) 1
Clothes Dryer ( gas ) 1
Clothes Washer 1
A/C Window Unit 1
FAU 1
Garage Area 1
EVSE Controller 1
A/C Unit 1
Cooktop 1
Oven 1
Sub- panel 1
Water Heater 1
Heated Spa 1
Heat Pump 1
Pool Filter 1/2 hp 1
I TOTAL: |
Applying Demand Load I
First VA at indicated %
Second VA at indicated %
TOTAL LOADS
: • :^Applyiflg Derrtarid Load |
TOTAL SERVICE ENTRANCE LOAD
I Square ft I
3518
I VA/cktJ
1500
1500
e| Volts |
120
120
120
120
120
120
120
120
120
120
120
120
240
240
240
240
240
240
240
240
240
1 VA I
8000
41584
1 V |
240 |[
VA/Sqft |
3
#ckts |
1
2
"Amps |
10
9.3
12
5
0
0
0
0
0
0
6.25
0
30
23.4
32
8.3
0
0
30
0
4.9
E
% 1
100
40
-.A I
102.64 ||
VA
10554
VA
1500
3000
VA
1200
1116
1440
600
0
0
0
0
0
0
750
0
7200
5616
7680
1992
0
0
7200
0
1176
49584
VA
8000
16633.6
24633.6
VA
24633.6
NOTES: