Loading...
HomeMy WebLinkAbout1004 CANVASBACK CT; ; CB110879; Permit04-27-2011 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Cogeneration Permit Permit No:CB110879 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 1004 CANVASBACK CT CBAD COGEN Sub Type: EVG 2146434200 Lot#: 0 $0.00 Construction Type: NEW Reference #: SMITH RES- INSTALL 40A CIRCUIT & NEMA 6-50 RECEPTACLE FOR EV EQUIPMENT Applicant: SUNWEST ELECTRIC INC 3064 E MIRALOMA AV 92806 714630-8700 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check#: Owner: SMITH KENNETH B&BRIDGET A 1004 CANVASBACK CT CARLSBAD CA 92011 ISSUED 04/27/2011 LSM 04/27/2011 04/27/2011 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Green Bldg Stands (SB1473) Fee Total Fees: $22.00 Total $0.00 $20.00 $0.00 $0.00 $0.00 $1.00 $1.00 Payments To Date: PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Additional Fees TOTAL PERMIT FEES $22.00 Balance Due: $0.00 $0.00 $0.00 $0.00 $22.00 $0.00 Inspector: FINAL APPROVAL Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax 760-602-8558 www.carlsbadca.gov Plan Check No. Q&\\ Est. Value Plan Ck. Deposit SWPPP JOB ADDRESS 1004 CANVASBACK STREET- CT/PROJECT #PHASE* |#OFIMTS I#BEDROOMS SUITE#/SPACE#/UNIT# LOT#ft BATHROOMS 1 TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) Install 40A circuit and NEMA 6-50 receptacle for Electrical Vehicle Equipment EXISTING USE PROPOSED USE GARAGE (SF) 300 PATIOS (SF)DECKS (SF)FIREPLACE NCT~I AIR CONDITIONING YES | |NO I I FIRE SPRINKLERS CONTACT NAME (If Different Font Applicant)APPLICANT NAME Shaun Eastman ADDRESS ADDRESS 3064 E. Miraloma Ave. CITY STATE ZIP CITY Anaheim STATE CA ZIP 92806 PHONE FAX PHONE 714-678-0083 FAX 714-630-8740 EMAIL EMAIL seastman@sunwestelect.com PROPERTY OWNER NAME KEN SMITH CONTRACTOR BUS. NAME Sunwest Electric, Inc. ADDRESS 1004 CANVASBACK ST. ADDRESS 3064 E. Miraloma Ave. CITY Carlsbad STATE CA ZIP 92011 CITY Anaheim STATE CA ZIP 92806 PHONE 858-583-2115 FAX PHONE 714-60-8700 FAX 714-630-8740 EMAIL EMAIL seastman@sunwestelect.com ARCH/DESIGNER NAME & ADDRESS STATE LIC. # 511697 CLASS CIO CITY BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapppcant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500)). : I certify that in the performance of the work for which this permit is issued, I shall not e f any person in any manner so as to become subject to the Workers' Compensation Laws of tflpyerto criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: \ 11 have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700.fif the Labor Code, for the performance of the work for which this permit is issued. 1/J I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance/of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co old Republic insurance Corp pofcy No / /Vicw4ii2iou3 Expiration Date . This section need not be completed if the permit is for one hundred dollars ($100) or less. [ | Certificate of Exemption: I California. WARNING: Failure to secure workers' compensation coverage is unlawful, an addition to the cost of compen J&$ CONTRACTOR SIGNATURE / hereby affirm that I am exempt from Contractor's License Law for the following reason: | | I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such Improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I/I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). | [ I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. I lYes I JNo 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): .^PROPERTY OWNER SIGNATURE 0AGENT DATE Is the applicant or future building occupant required to submit a business clan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? | |Yes I iNo Is the applicant or future building occupant required to obtain a permit from the air pollution control district or ainjuality management district? I lyes I I No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? I lYes l~nNo CY MAY NOT BE ISSUED I EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address n/a I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purf AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINSTjE OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 s EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation i 180 days from the date of such peiajtpr if Uie-bttMBg-eumrk authorized by s ^APPLICANT'S SIGNATUK f\ ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD JD CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. > in height i null and void if the building or work authorized by such permit is not commenced within (trie after the work is commenced for a oeriod of 180 days (Section 106.4.4 Uniform Building Code). t/_ DATE City of Carlsbad Bldg Inspection Request For: 05/19/2011 Permit* CB110879 Title: SMITH RES- INSTALL 40A CIRCUIT Inspector Assignment: Description: & NEMA 6-50 RECEPTACLE FOR EV EQUIPMENT NO NEW METER/ NO PANEL UPGRADE/ EQUIP IN f+ A n A f+tz Type:COGEN Sub Type: EVG Job Address: 1004 CANVASBACK CT Suite: Lot: 0 Location: APPLICANT SUNWEST ELECTRIC INC Owner: SMITH KENNETH B&BRIDGET A Remarks: car charger inspection Phone: 7143157753 Inspect Total Time: CD Description 39 Final Electrical Act Comments Requested By: CARLOS Entered By: CHRISTINE I(Jo M Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Inspection History Date Description Act Insp Comments LUi LULJJ C/) %T>\ x «u \s\ <<* >. e.\ *4» ^ "o o^ ^ -£> 4 • •> o o UJCO UJo a: UJ_i z>o CM O CM i— >. P U-; CCL 5 > ^09 ° LU LLJO LUCO o Q-oa I' UJC) o LLJ UJ \-/ "3 ^co < r- GENERAL NOTES & SPECIFICATIONS (SHEET 1 OF 2) WORK SPECIFIED HEREIN WORK UNDER THIS SPECIFICATION INCLUDES FURNISHING ALL MATERIAL, LABOR, EQUIPMENT, ETC., AND FINAL CONNECTION TO EQUIPMENT IN ORDER TO PROVIDE THE OWNER WITH A COMPLETE AND PROPERLY FUNCTIONAL ELECTRIC VEHICLE SUPPLY EQUIPMENT. IN GENERAL, THE WORK SHALL CONSIST OF BUT NOT BE LIMITED TO THE FOLLOWING: • FURNISH AND INSTALL ALL OF THE EQUIPMENT AND THE POWER SUPPLY FOR THE ELECTRIC VEHICLE SUPPLY EQUIPMENT, INCLUDING; CIRCUIT PROTECTION DEVICES AND BRANCH FEEDERS. • PRIOR TO INSTALLATION AND FINAL CONNECTION, VERIFY ELECTRICAL CHARACTERISTICS OF THE DISTRIBUTION SYSTEM AND LOCATION OF THE EVSE, • GROUT AND SEAL ALL CONDUIT PENETRATIONS OF WALLS AND ROOF TO MAINTAIN FIRE RATING AND WATERTIGHT INTEGRITY OF WALLS AND ROOF. GENERAL REQUIREMENTS THE CONTRACTOR WILL BE HELD TO HAVE THOROUGHLY REVIEWED GENERAL CONSTRUCTION DRAWINGS. EXAMINED THE SITE. PREMISES AND SATISFIED HIMSELF AS TO EXISTING CONDITIONS UNDER WHICH HE WILL BE OBLIGED TO OPERATE OR WHICH WILL IN ANY MANNER AFFECT THE WORK UNDER THIS CONTRACT. NO SUBSEQUENT ALLOWANCE WILL BE MADE IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART. PROVIDE STANDARD PRODUCTS OF ESTABLISHED MANUFACTURERS REGULARLY ENGAGED IN THE PRODUCTION OF SUCH EQUIPMENT. PROVIDE NEW MATERIAL. APPARATUS AND EQUIPMENT OF THE BEST PRACTICE OF THE ELECTRICAL TRADE AND BY SKILLED CRAFTSMEN. ALL EQUIPMENT SHALL BE LISTED BY UNDERWRITERS LABORATORIES, OR EQUIVALENT NRTL, FOR USE INTENDED. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND THE CONTRACTOR SHALL HARMONIZE HIS WORK SO THAT EACH PIECE OF EQUIPMENT WILL BE INSTALLED SO AS TO FUNCTION PROPERLY. COOPERATE WITH OWNER AND VERIFY ALL EQUIPMENT LOCATIONS. WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL ORDINANCES AND REGULATIONS OF STATE, COUNTY, MUNICIPAL AUTHORITIES. UTILITY COMPANY, N.E.C. AS SHOWN ON CONSTRUCTION DOCUMENTS. SEE CONSTRUCTION DRAWINGS FOR EQUIPMENT LOCATIONS. AND APPLICABLE ELEVATIONS AND DETAILS. ELECTRICAL CONTRACTOR TO VERIFY AND ACKNOWLEDGE ALL CODES AND REGULATIONS PERTAINING TO THIS PROJECT. REFER TO THE NATIONAL ELECTRIC CODE, ARTICLE 625 AND ALL OTHER APPLICABLE SECTIONS OF THE NEC, CONDUITS SHALL BE SIZED IN ACCORDANCE WITH THE APPROPRIATE TABLE OF NEC, AND SHALL BE OF SUCH SIZE AND SO INSTALLED THAT CONDUCTORS MAY BE DRAWN IN WITHOUT INJURY OR STRAIN. CONDUIT SHALL BE SECURED TO PULL BOXES, SUPPORT BOXES, OR OUTLET BOXES WITH GALVANIZED LOCKNUTS AND BUSHINGS. ALL CONDUITS SHALL BE RUN CONCEALED PRINCIPALLY IN OVERHEAD AND WALL CONSTRUCTION. ALL CONDUIT THAT MUST BE EXPOSED SHALL BE RUN PARALLEL WITH LINES OF THE BUILDING. CHASES AND OPENINGS IN WALLS, PARTITIONS AND FLOORS SHALL BE PROVIDED FOR INSTALLATION OF CONDUIT; ALL CONCEALED WORK SHALL BE DONE SO AS TO MINIMIZE CUTTING AND PATCHING. ALL CONDUIT NOT EMBEDDED IN CONCRETE SHALL BE FIRMLY SECURED BY LISTED PIPE CLAMPS, HANGERS. ETC. ELECTRICAL METALLIC TUBING: USED FOR ALL WIRING EXCEPT IN OR UNDER CONCRETE, EARTH, FILL, OR GROUTED BLOCK WALLS. GALVANIZED STEEL CONDUIT: USED FOR ALL WIRING IN OR UNDER CONCRETE. EARTH, FILL AND GROUTED WALLS. IN EARTH OR FILL. COAT WITH POLYETHYLENE TAPE. SPIRAL WRAPPED TO NOT LESS THAN 40MILS. NON-METALLIC: LISTED. SCHEDULE 40, PVC MAY BE USED FOR BRANCH FEEDER CIRCUITS IF RUN UNDER CONCRETE FLOOR. PROVIDE BONO WIRE PER NEC. PVC CONDUIT SHALL BE BURIED MINIMUM OF 24 INCHES IF NOT INSTALLED UNDER CONCRETE OR ENCASED IN 3 INCH CONCRETE ENVELOPE, FLEXIBLE METALLIC CONDUIT OR METAL-CLAD CABLE: MAY BE USED FOR SHORT FINAL CONNECTIONS FOR INDOOR EQUIPMENT. PROVIDE INSULATED COPPER BOND WIRE IN ALL FLEXIBLE RACEWAYS AND SIZED PER NEC- 250. LIQUIDTIGHT FLEXIBLE METALIC CONDUIT: SHALL BE USED OUTDOOR AND IN MOIST LOCATIONS WITH LISTED TERMINATION FITTINGS. *•* V* gm. . . 430 S SECOND AVE. PROJECTSPM f*mi£*rt PHOENIX, AZ 85003^*»nWJO>»l TEL: 602-345-9006 APPROVALS DATE PROJECT DRAWN CHECKED ENGINEER ALL CONDUCTORS SHALL BE SOFT DRAWN ANNEALED COPPER HAVING PURE COPPER CONDUCTIVITY OF NOT LESS THAN 9SZ. UNIFORM IN CROSS SECTION, FREE FROM FLAWS. SCALES, AND OTHER IMPERFECTIONS. CONDUCTORS IN CONDUIT: •XHHW-2 OR THWN-2 INSULATION FOR ALL EXTERIOR FEEDERS IN CONDUIT, •THHN-2 INSULATION FOR ALL INDOOR BRANCH CIRCUITS IN CONDUIT. •MINIMUM SIZE WIRE SHALL BE #14 AWG COPPER. •NO WIRE MAY BE DRAWN INTO CONDUIT UNTIL CONDUIT SYSTEM IS COMPLETE. CONDUCTOR PULLING LUBRICANT SHALL BE USED TO FACILITATE WIRE PULLING. NONMETALLIC-SHEATHED CABLE: NON-METALLIC SHEATHED CABLES SIZED PER NEC MAY PROVIDE ALL WIRING CONNECTIONS FOR EQUIPMENT FURNISHED UNDER OTHER SECTIONS OF THE SPECIFICATIONS ALL WIRING SHALL BE TESTED UPON COMPLETION OF WORK. AND ADJUSTMENTS MADE NECESSARY FOR SATISFACTORY OPERATION OF THE SYSTEM. WHERE SUBJECT TO PHYSICAL DAMAGE. CONDUCTORS SHALL BE ADEQUATELY PROTECTED. WHEN THE WIRING METHOD IS INSTALLED THROUGH BORED HOLES IN JOISTS. RAFTERS OR WOOD MEMBERS, HOLES SHALL BE BORED SO THAT THE EDGE OF THE HOLE IS NOT LESS THAN 1-1/4" FROM THE NEAREST EDGE OF THE WOOD MEMBER. WHERE THIS DISTANCE CANNOT BE MAINTAINED, THE CABLE SHALL BE PROTECTED FROM PENETRATION BY SCREWS OR NAILS BY A STEEL PLATE. AT LEAST 1/16" THICK. AND OF APPROPRIATE LENGTH AND WIDTH INSTALLED TO COVER THE AREA OF THE WIRING. •GROUNDING CONDUCTORS: ALL GROUND CONDUCTORS SHALL BE SIZED PER NEC 250 PER EACH APPLICATION. NAUE: KEN SMITH ADDRESS 1Q04 CANVASBACK ST. CALABASES.CA 92011 M.G.R. REV. - - SIZE PROJECT 1 A DO NOT SCALE DRAWINGS SCALE CODE INTENT NO. DWG NO. NA | SHEET _ OF GENERAL NOTES & SPECIFICATIONS (SHEET 2 OF 2) SAFETY SWITCHES SAFETY SWITCHES, SHALL BE HEAVY DUTY TYPE, 240 VOLT MINIMUM WITH THE EXACT NUMBER OF POLES REQUIRED. ALL SAFETY SWITCHES SHALL BE OF THE FUSIBLE TYPE, FUSES SHALL BE SIZED AS RECOMMENDED BY EQUIPMENT MANUFACTURER, THE SWITCH SIZE SHALL BE AS REQUIRED BY THE NEC AND AS INDICATED ON THE DRAWINGS AND SIZED PER HORSEPOWER RATING. WHERE OUTSIDE THE BUILDING, THE SWITCHES SHALL BE RAINTIGHT TYPE NEMA-3R. FUSES FUSES SHALL BE OF THE TYPE, SIZE AND RATING AS INDICATED ON THE DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ENGINEER ON RECORD FOR RESOLUTION. GROUNDING ELECTRICAL CONTRACTOR SHALL VERIFY PROPER GROUNDING CONNECTIONS, GROUND CONDUCTORS AND INSTALL AS PER THE GROUNDING DETAILS AS INDICATED IN THESE DRAWINGS. ALL EQUIPMENT AND ENCLOSURES, AND THE COMPLETE CONDUIT SYSTEM SHALL BE GROUNDED SECURELY IN ACCORDANCE WITH PERTINENT SECTIONS OF NEC, ARTICLE 250. ALL ELECTRICALLY OPERATED EQUIPMENT SHALL BE BONDED TO THE GROUNDING SYSTEM. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ENGINEER ON RECORD FOR RESOLUTION. BRANCH PANELS BRANCH PANELBOARDS ARE EXISTING AND SHALL BE USED. BREAKER TYPE SHALL BE MATCHED WITH THE EXISTING AND RATED AS SPECIFIED ON THE DRAWINGS. TIE BARS TO FORM TWO-POLE BREAKERS WILL NOT BE ACCEPTED. EACH PANEL SHALL BE PROVIDED WITH A TYPEWRITTEN SHEET INSTALLED ON THE DOOR, WHICH IDENTIFY THE ASSIGNMENT OF EACH BREAKER. FINAL INSPECTION & TESTS FURNISH ALL METERS, CABLE CONNECTIONS AND APPARATUS NECESSARY FOR TESTING. TEST SYSTEM FOR SHORTS AND GROUNDS. FAULTY WIRING SHALL BE REMOVED AND REPLACED. ANY DEVICE, APPARATUS OR FIXTURE INSTALLED SHOWING SUB-STANDARD PERFORMANCE SHALL BE REMOVED AND REPLACED AT NO ADDITIONAL COST TO THE OWNER. FIELD NOTES ^Project 430 S SECOND AVE. PHOENIX. AZ 85003TEL: 602-3+5-9006 APPROVALS DRAWN CHECKED ENGINEER M.G.R. REV. PROJECT # _ DO NOT SCALE DRAWINGS PROJECT NAME:KEN SMITH PROJECT ADDRESS:1004CANVASBACKST. CALABASES, CA 92011 SIZE A CODE INTENT NO.DWG NO. SCALE NA SHEET OF SMITH / SDR-0797 RESIDENTIAL LOAD CALCULATION PANEL TYPE : CUTLER MAIN CB AMPS: 200 General Lighting and receptacle loads :: :!l I NEC 2008- 220.83 (A)(1) | Outside dimensions of home (exclude garage) Small appliance and laundry load j NEC 2008-!220;83 (A)(2) | Small appliance Laundry special ftppiiance Loaas I NEC2008^220.83(A)(3) |Phas Dishwasher 1 Disposal 1 Microwave 1 Exhaust Hood 1 Refrigerator 1 Trash Compactor 1 Clothes Dryer ( electric ) 1 Clothes Dryer ( gas ) 1 Clothes Washer 1 A/C Window Unit 1 FAU 1 Garage Area 1 EVSE Controller 1 A/C Unit 1 Cooktop 1 Oven 1 Sub- panel 1 Water Heater 1 Heated Spa 1 Heat Pump 1 Pool Filter 1/2 hp 1 I TOTAL: | Applying Demand Load I First VA at indicated % Second VA at indicated % TOTAL LOADS : • :^Applyiflg Derrtarid Load | TOTAL SERVICE ENTRANCE LOAD I Square ft I 3518 I VA/cktJ 1500 1500 e| Volts | 120 120 120 120 120 120 120 120 120 120 120 120 240 240 240 240 240 240 240 240 240 1 VA I 8000 41584 1 V | 240 |[ VA/Sqft | 3 #ckts | 1 2 "Amps | 10 9.3 12 5 0 0 0 0 0 0 6.25 0 30 23.4 32 8.3 0 0 30 0 4.9 E % 1 100 40 -.A I 102.64 || VA 10554 VA 1500 3000 VA 1200 1116 1440 600 0 0 0 0 0 0 750 0 7200 5616 7680 1992 0 0 7200 0 1176 49584 VA 8000 16633.6 24633.6 VA 24633.6 NOTES: GO — O O ocz—1 GO O I cn < £-o <D'n