HomeMy WebLinkAbout101 CANNON RD; ; CB020239; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Miscellaneous Permit Permit No:CB020239 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: 101 CANNON RDCBAD MISC 2100331800 $20,000.00 Subtype: OTHER Lot #: 0 REYNOLDS RESIDENCE ADD ELEVATOR Status: ISSUED Applied: 01/23/2002 Entered By: MDP Plan Approved: 02/21/2002 Issued: 02/21/2002 Inspect Area: Applicant: WEBER STEVEN 7930 LA CAPELA CARLSBAD CA 92009 760 753-8486 1478 02/21/02 0002 01 02 '- . CGP 294. Total Fees: $294.00 Balance Due: $294.00 Miscelaneous Fee #1 Miscelaneous Fee #2 Additional Fees TOTAL PERMIT FEES PLANCK&PERMIT PERMIT HAS EXPIRED Inspecto FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK N0._ EST. VAL. Plan Ck. Deposit Validated Bv Date Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total 9 of units Assessor's Parcel #Existing Use Proposed Use Description of Work SQ. FT.#of Stories •a •S^YI i-a*'™ ';aAr , # of Bedrooms # of Bathrooms Name Address City State/Zip Telephone Fax* Name Address City State/Zip Telephone (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [*50O]), Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name State License # Address City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 19100] OR LESS) O CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to Mcura workers' compensation coverage Is unlawful, and shaH subject an employer to criminal penalties and dvH fines up to one hundred thousand dollars ($100,000), in addition to th« cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney'! fees. SIGNATURE DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is ld within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). n I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QrJO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firmrto provide the proposed construction (include name / address / phone number / contractors license number):-fasshotoff^ ffrfriiI iw j- /}&.&&- - ,f • - . r i • i 4. I plan to provide portions of the work, burr have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work of work): I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type PROPERTY OWNER SIGNATURE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25606, 2SS33 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit^esrjecNjy the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit usnot oomrnienced within 180 days from the date of such permit or if the building or work authorized by such permit Is suspended or abandoned at any time after the work [s cgnfmemai for a periodpfty8j) d«tys\(SectJol) 106.4.4 Uniform Building Code). / _ s *)APPLICANT'S SIGNA DATE WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 01/28/2003 Permit* CB020239 Title: REYNOLDS RESIDENCE Description: ADD ELEVATOR Inspector Assignment: JC 101 CANNON RD Lot Type: MISC Job Address: Suite: Location: APPLICANT WEBER STEVEN Owner: REYNOLDS HUGO&PATSY Remarks: ELEVATOR INSPECTION Total Time: Sub Type: OTHER Phone: 7604583333 Inspector Requested By: BARNEY Entered By: CHRISTINE CD Description 19 Final Structural 29 Final Plumbing Comment Associated PCRs/CVs Insoection History Date 05/15/2002 05/15/2002 03/19/2002 03/18/2002 03/15/2002 03/15/2002 03/15/2002 03/13/2002 03/13/2002 03/13/2002 03/12/2002 03/12/2002 03/12/2002 03/1 1/2002 03/1 1/2002 03/11/2002 03/05/2002 03/05/2002 03/05/2002 02/27/2002 Description 19 39 17 17 14 16 17 13 16 17 14 18 34 14 18 31 13 14 34 11 Final Structural Final Electrical Interior Lath/Drywall Interior Lath/Drywall Frame/Steel/Bolting/Welding Insulation Interior Lath/Drywall Shear Panels/HD's Insulation Interior Lath/Drywall Frame/Steel/Bolting/Welding Exterior Lath/Drywall Rough Electric Frame/Steel/Bolting/Welding Exterior Lath/Drywall Underground/Conduit-Wiring Shear Panels/HD's Frame/Steel/Bolting/Welding Rough Electric Ftg/Foundation/Piers Act CO CO AP NR AP AP PA AP PA NR PA AP AP CA CA CA NR NR NR AP Insp PD PD JC JC JC JC JC JC JC JC JC JC JC JC JC JC JC JC JC JC Comments SMOKE DETECTORS INSIDE SHAFT INSIDE SHAFT ONLY NEW DETAIL NEEDED FOR 2 01 OK TO INSULATE PLAN CHANGE (BACK TO ESGIL) EsGil Corporation In Partners/tip with government for Suififotff Safety DATE: February 2O, 2O02 JURISDICTION: Carlsbad PLAN CHECK NO.: 02-239 SET: II PROJECT ADDRESS: 1O1 Cannon Road PROJECT NAME: Add Elevator Only - a APPLICANT a JURIS. a PLAN REVIEWER a FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed checklist and should be corrected and resubmitted for a complete recheck. I I The checklist transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the checklist is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the checklist has been sent to: I I Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steven Weber Telephone #: 760-753-8486 Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Tony Embuido Esgil Corporation D GA D MB D EJ PC Enclosures: LOG tmsmtt.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 STEVEN D. WEBER ARCHITECT March 13,2002 City of Carlsbad Building Department Building inspections Division Re: 02-239 To Whom It May Concern: 1. Detail 2 page D1 Remove double joist and replace with single blocking between joists 2. detail 2 page D1 Remove shear transfer A35 between joist and top plate 3. floor framing plan Page 4 Delete HUC 410 and double joist If you have any more questions please call Steven D. Weber PO Box 23OO78Enchtas, Ca 92Oa3-0078 76O-753-8486 Office 76CM36-OE6O Fax EsGil Corporation In Partners/lip Witk government for Quitting Safety DATE: February 04, 20O2 JURISDICTION: Carlsbad O~PLAN REVIEWER a FILE PLAN CHECK NO.: 02-239 SET: I PROJECT ADDRESS: 101 Cannon Road PROJECT NAME: Add Elevator - The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by buildincj department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed checklist and should be corrected and resubmitted for a complete recheck. The checklist transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the checklist is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the checklist has been sent to: Steven Weber P.O. Box 230078, Encinitas, CA 92023 I I Esgil Corporation staff did not advise the applicant that the plan check has been completed. ™ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steven Weber Telephone #: 760-753-8486 Date contacted:2-^-02- (by:fc*^) Fax #: Mail Telephone Fax In Person REMARKS: By: Tony Embuido Enclosures: Esgil Corporation D GA D MB D EJ D PC 01/25/02 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 4- San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: O2-239 JURISDICTION: Carlsbad PROJECT ADDRESS: 101 Cannon Road FLOOR AREA: + REMARKS: Add elevator- DATE PLANS RECEIVED BY JURISDICTION: 01/23/02 DATE INITIAL PLAN REVIEW COMPLETED: February 04, 2002 STORIES: 2 + B (N/C) HEIGHT: N/C DATE PLANS RECEIVED BY ESGIL CORPORATION: 01/25/02 PLAN REVIEWER: Tony Embu}do FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with the 1998 edition of the California Building Code (Title 24), which adopts the following model codes: 1997 UBC, 1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process, please note on this list (or a copy) where each correction Item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked UP list when you submit the revised plans. • PLANS • Please make all corrections on the original tracings, as requested in the correction list. Submit (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. > NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGif Corporation is complete. 1. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 2. Final set of plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). 3. Show on the title sheet all structures, pools, site retaining walls, etc. included under this application. Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included." Section 106.3.3. Separate permit is required per above. 4. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: • Occupancy Group • Description of Use • Stories • FIRE PROTECTION 5. When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided, except that smoke detectors added at existing construction need only be battery powered. Section 310.9.1.2. • GARAGE 6. Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 3-B, Section 302.4. See where shown at garage. 7. All elements supporting floor above garage, including walls/beams/columns supporting floor joists, must have one-hour fire-resistive protection on the garage side. Section 302.2. See new framing due to elevator shaft where It occurs. • FOUNDATION REQUIREMENTS 8. All new residential buildings, including additions, require a soil's report. a) Provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804. 9. In Seismic Zone 4, each site shall be assigned a near-source factor. Identify this value in the soil's report and on the plans. Section 1629.4.2. 10. Investigate the potential for seismically induced soil liquefaction & soil instability in Seismic Zones 3 and 4. Section 1804.5. 11. Indicate size and depth of footings for new elevator shaft. See foundation plan and details and specify for clarity purposes. 12. Note on the plan the soil's classification, whether or not the soil is expansive and note the allowable bearing value. Section 106.3.3. 13. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). 14. Foundation plan and details have not been completely checked due to lack of soil's report. Additional corrections may follow upon submittal, unless exempt by the City. • FRAMING/STRUCTURAL 15. Provide calculations for main vertical and horizontal framing members and footings. Section 106.3.3. None provided. 16. Show on the plans all structural requirements developed in the structural calculations. Section 106.3.3. (When design calc's. have been submitted.) • ELEVATORS 17. Every opening into an elevator shaft enclosure shall be protected by a self- closing fire assembly having a one-hour fire rating in one-hour shafts. Section 711.4. Specify on floor plans for clarity purposes. 18. Elevator shafts extending through more than two floor levels shall be vented to the outside. The area of vent shall be not less than 3 1/2% of the shaft area and a minimum of 3 square feet per elevator. Section 3004. 19. Provide notes, details or specifications to show the elevator will comply with UBC Sections 3002-3007. • MISCELLANEOUS 20. Clearly describe on the cover sheet the exact work being done for^his permit. Also, clarify new living area of 103-sq. ft. at 2nd floor. Additional corrections may follow upon clarification. 21. Clarify wall legends indicating which walls are new and existing. It appears to be incorrect. Prove otherwise. 22. Nails for shear transfer connection (using A35's, etc.) may not be driven parallel to the flanges of TJI's (i.e., along the sides), per city policy, unless specific written approval from Trus-Joist Macmillan is first obtained. Details or notes on the plans should make this clear. Nails may be driven perpendicular to TJI flanges. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No Q The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Tony Embuido at Esgil Corporation. Thank you. VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: O2-239 PREPARED BY: Tony Embuido DATE: February 04, 2O02 BUILDING ADDRESS: 101 Cannon Road BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: V-N BUILDING PORTION Addition/Remodel Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq.Ft.) CB Valuation Multiplier By Ordinance Reg. Mod. VALUE ($). * 20,000 y 20,000 $176.69 Plan Check Fee by Ordinance Type of Review: D Repetitive Fee Repeats Complete Review D Other . Hourly Structural Only Hour* Esgll Plan Review Fee $114.85 $98.95 Comments: Sheet 1 of 1 macvalue.doc STEVEN D. WEBER ARCHITECT * •* * *• • • * March 5,2002 City of Carlsbad Building Department Plan Ck# 02-239 To The Building inspector, • \' In regards to the stud spacing, the studs used will be 2x4 @ 8" oc (not 2x6 @ 16" oc as shown on the plans) These wilt be sufficient for the additional loads anticipated for this project. Sincerely, —\ vO Steven D. Weber PO Box 23O078Encirtas, Ca 93023-0078 760-753-8486 Office 76O-436-O26O Fax PALOS VERDES Engineering Civil and Structural Consulting Structural Calculations Elevator Addition 6027-1 Paseo Delicias P.O. Box 2211 Rancho Santa Fe California 92067 pvecfsf@earthllnk.net 858 759 2434 858 759 8324 FAX PREPARED FOR Steve Weber, Architect 7930 La Capela Place Carlsbad, CA 92009 PROJECT Reynolds Residence 101 Cannon Road Carlsbad, CA 92009 Paul S. Christenson RCE C57182, exp. 12-31-05 February 19,2002 PVEC File No. 24-02-134 PALOS VERDES Engineering Civil and Structural Consulting S027-IPaseoDelk3a8 P.O. Box 2211 Rancho Santa Fe California 92067 pveersf@earthHnk.net 858 758 2434 858 759 8324 FAX 1 0 Criteria: Code: Timber Glue-Lam Dcoma: 1997 Unrtbrrn Burking Code Douglas Fir-Larch (DF-L), WWPA or WCLiB 2x WaH Framing: DF-L« (unless noted otherwise) 2x Rafters & Joists: DF-L42 " Posts* Beams: DF-L#1 " Simple Span: Cantilevers: Grade 24f-V4(DF/DF) Grade 24F-V8 (DF/DF) Sheathing: Min. APA-Rated Sheathing, Exposure 1, Plywood or OSB (U.N.O.) Engineered Framing: Concrete: Wood l-Joist* LVL.PSL TJI/Pt0 150.250.350.550 - 1.9eMk*ollarn, 2.0EParallarn - NER-200 NER-481 CompreBatve Strength Q 28 days per ASTM C39-96: Footings: fc = 2500 psi Grade Beams: fc=3000psi Concrete Blocte Grade N-l per ASTM C90-95, fm = 1500 psi per ASTM E447-92 Mortar Grout: Reinforcing Steel: Structural Steel: Welding Electrodes: Bolts: Soils: References: Type S Mortar Cement per ASTM C270-95, Min. fm = 1800 psi @ 28 days. Coarse Grout w/ W Max. Aggregate per ASTM C476-91. Min. fm » 2000 psi Q 28 days. #4 & Larger #3 & Smaller ASTMAB15-60(Fy = 60ksi) ASTM A515-40 (Fy - 40 ksi) W Shapes: ASTM A992, Fy= 50-65 ksi Plates. Angles, Channels: ASTM A36, Fy « 36 ksi Tube Shapes Pipe Shapes: Structural Steel: A615-60Rebar Sift Plate Anchor Bolts & Threaded Rods: Steel Moment & Braced Frames: ASTM A500, Grade B. Fy= 46 ksi ASTM A53, Grade B,Fy=35 ksi E70-T6 E90 Series A307 Quality Minirnum A325 (Bearing, U.N.O.) Palos Verdes Engineering Corporation Consulting Structural Engineers 6027-1 Paseo Delicias • P.O. Box 2211 • Rancbo Santa Fe, CA 92067 Telephone (858) 759*2434 • Fax (858) 759-8324 JOB . iV( SHEET NO Z,OF CALCULATED BY Be CHECKED BY SCALE DATE 2.O L\ 2. 2 OL~ CX L DL_ ^^ SD-SO/L \/*0. 7SPL Foft. UT« Palos Verdes Engineering Corporation Consulting Structural Engineers 6027-1 Paseo Delicias • P.O. Box 22 11 • Rancho Santa Fc, CA 92067 Telephone (858) 759-2434 • Fax (858) 759-8324 SHEET NO OF CALCULATED BY P* DATE CHECKED BY _ DATE SCALEawuoi .MO EXtSTia<E,At^ALL£ WAoE BF-^i R.EHoufO r He THAr U<5UcO EPFK SHsr^i te ^HI£«LUAU,S), •*• Mo CWAMGe (S fZEdrfU/rt^FO TB TMP SH&AO. "i I?" feE LU o: eft O 0 vO *^» •o 09-06-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No:PCR02070 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: Applicant: PHILIP DRESMAN 458-3333 101 CANNON RDCBAD PCR 2100331800 Lot#: $0.00 Construction Type: 0 NEW REYNOLDS RES-REV FRAMING @ ELEVATOR SHAFT Status: ISSUED Applied: 03/08/2002 Entered By: RMA Plan Approved: 03/11 /2002 Issued: 03/11/2002 Inspect Area: Owner: REYNOLDS HUGO&PATSY 919 3RD ST NORCO CA 92860 Plan Check Revision Fee Additional Fees $0.00 $0.00 Total Fees:$0.00 Total Payments To Date:$0.00 Balance Due:$0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing In accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other simitar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to thte. or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION ^sfoQ CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK WbJiG/tfi2.07D EST. VAL. 1 Plan Ck. Deposit Validated Bv » / Date H1 />/ /f V" / •> - — Address (Include Bldg/Suite *) lOf CAcJ*j£>*J ft fS . Business Name (at this address) Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total * of units Assessor's Parcel #Existing Use Proposed Use Description of Work SO. FT.#of Stories 9 of Bedrooms >' # of Bathrooms Name Address State/Zip Telephone f UoC O Fax f Name Address City State/Zip Telephone f (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, altar, improve, demolish or repair any structure, prior to Ha issuance, atso requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Arty violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). I* dc&A^ 2^y flgscftflv IVl r^....T>AS CA Name m State License # & 7 ( 4-S" Address ,0 O'J>t- License Class §City State/Zip City Business License f Telephone # Designer Name State License * Address City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: O I have end will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued. My worker's compensation Insurance carrier and policy number are: Insurance Company Policy No. Expiration Data (THIS SECTION NEED NOT BE COMPLETED IP THE PERMIT IS FOR ONE HUNDRED DOLLARS 1*100] OR LESS) Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so aa to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shaJ subject an employer to criminal penalties and dvfl fines up to one hundred thousand dollars (9100,000), In addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code. Interest and attorney's fees. SIQNATURE_ __^^__ DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: O l> as owner of the property or my employees with wages as their sole compensation, wilt do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who doe* such work himself or through his own employees, provided that such Improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively. contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I sm exempt under Section Business and Professions Code for this reason: 1 . I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following parson (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): __ ____ __ ___ _ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work):_ ___ _ PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plen, acutely hazardous materials registration form or risk management and prevention program under Sections 2SS05, 25533 or 26534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES. A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there Is a construction lending agency for the performance of the work for which this permit is issued {Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state thst the above information is correct and that the information on the plans Is sccurate. I agree to comply wrth aH City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit Is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories In height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or wo* authorized by such permit Is not commenced within 1 80 days from the date of such permH or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance EsGil Corporation In TartntTsfap witfi government for SuiG&tff Safety DATE: March 11, 2002 Q APPLICANT ^C JURIS. JURISDICTION: Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO.: 02-239 REV (PCR02070) SET: I PROJECT ADDRESS: 1O1 Cannon Rd. PROJECT NAME: Revise Stud Size/Spacing at Elevator Shaft IXI The sheet transmitted herewith substantially complies with the jurisdiction's building codes. ] The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. |~1 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [~1 The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ^] The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Applicant Telephone #: appt. Date contacted: 3/11/02 (by: kc) Fax #: Mail Telephone Fax In Person REMARKS: Plans hand-carried to city by applicant. By: Kurt Culver Enclosures: Esgil Corporation O GA D MB D EJ D PC log tmsmfl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4- (858)560-1468 4- Fax (858) 560-1576 Palos Verdes Engineering Corporation Consulting Structural Engineers 6027-1 Paseo Deltcias • P.O. Box 2211 • Rancho Santa Fe, CA 92067 Telephone (858) 759-2434 • Fsx (858) 759-8324 JOB ZVOt-lVf SHEET NO OF CALCULATED BY f»5C CHECKED BY SCALE DATE DATE ol Ro OK 72? 01= 2< 5T005e&i STEVEN D. WEBER ARCHITECT March 5, 2002 City of Carlsbad Building Department Plan Ck# 02-239 To The Building inspector, In regards to the stud spacing, the studs used will be 2x4 @ 8" oc (not 2x6 @ 16" oc as shown on the plans) These will be sufficient for the additional loads anticipated for this project. Sincerely, vO Steven D. Weber PO Box 230O78 Encirttas, Ca 92O23-O078 760-753-8^86 Office 76CM36-O260 Fax