Loading...
HomeMy WebLinkAbout1014 TULIP WAY; ; CB052057; Permit01-05-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No CB052057 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title Applicant PERRY BILL 1014 TULIP WYCBAD RESDNTL 2144101200 $283,250 00 0 0 BAUM RESIDENCE-ADD 2101 SF 2ND Sub Type Lot# Construction Type Reference # Structure Type Bathrooms RAD 0 NEW Status Applied Entered By Plan Approved Issued Inspect Area Ong PC# ISSUED 06/02/2005 MDP 01/05/2006 01/05/2006 STORY.ADD 3RD CAR GAR, REMODEL 1 738 1 ST FLOOR Plan Check* Owner BAUM RAYMOND C 550 2ND STREET ENCINITAS 920254 1014 TULIP WAY CARLSBAD CA 92009 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $1,11328 Meter Size $0 00 Add'l Reel Water Con Fee $723 63 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $2833 PFF (3105540) $0 00 PFF (4305540) $0 00 License Tax (3104193) $0 00 License Tax (4304193) $0 00 Traffic Impact Fee (3105541) $0 00 Traffic Impact Fee (4305541) $0 00 Sidewalk Fee $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Housing Impact Fee $0 00 Housing InLieu Fee Housing Credit Fee $0 00 Master Drainage Fee $0 00 Sewer Fee Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $15300 $4500 $6950 $000 $000 $000 $000 $000 $000 $2,13274 Total Fees $2,132 74 Total Payments To Date $2,13274 Balance Due $000 BUILDING PLANS _/_ IN STORAGE ATTACHED Inspector v_/ f * FINAL-A Date 5/ /PR b( AVAL JL r.|paran^p NOTICE Please take NOTICE that approval of your project includes the "Imposition* of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PRMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 1;s!l!" PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK NO EST Plan Ck Deposit Validated By Date '( Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor s Parcel #Existing Use 02 £ie«? Description g.f J/Vork L I .'„ .*e9w60NTACT1PERSON (if :diffe'rent from applicant) SQ FT #of Stories # of Bedrooms # of Bathrooms •Z-: Name Address 3 ;rt';APPLICANT :J;n Contractor Q Agent for Contractor *E3 Owner L^Agent for OwnerL^Age City StateTZip Telephone #Fax # Name 5 fCONTRACTOR - COMPANY NAME (Sec 7031 5 Business and Professions Cd3J—'fihySierty or CotirHy whicl^ requires b permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement ihat he is licensed pursuant to the provisions of the Contractor s License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code! or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars I$500J) Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name Address City State/Zip Telephone State License # 6 ;WQRkERSi COMPENSATION '.' . tfB' ... ,„:„; ""'];. Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations 0 I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) Q CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 000), in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code, interest and attorney s fees SIGNATURE DATE 7:» OWNER-BUILDER^DECLARATION "*!'• 1 hereby affirm that I am exempt from the Contractor s License Law for the following reason Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) J3, I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) l~l I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~l YES 0JJO 2 /TThav^/ have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work/ biffff have hired^the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) ftp " -'•-- - -. . 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY ; S V = Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? O YES d NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? O YES D NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 8 ^CONSTRUCTION LENDING AGENCY fp ' - I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER'S NAME LENDER'S ADDRESS SX APPLICANT? CERTIFICATION """:>i ••••*;': ^o.: .^ [„,„;,.. '""'" '\ ::" I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void it the building or work authorized by such permit is not commenced within 180 days from the date of suchirjgrmrt-qr if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a perjod^sPlSO days (Section lOjj^HTUniforfFi'Building Code) APPLICANT'S SIGNATURE s^^^-^^&Z—S <(=>^-i_ DATE £>' 1-~ <$ ^ WHITE File YELLOW Apifncant PINK Finance PERMIT APPLICATION .CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 PfMJJECT iNFORMATION ' .A"' : ..'/"' !<^" l£ U FOR OFFICE USE ONLY PLAN CHECK NO Ct&S 2 EST VAL Plan Ck Deposit Validated By Date Address (include Bldg/Suiti tt)Business Name (at this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total tt of units Assessor s Parcel tt Existing Use Proposed Use Description of Work ^.s^Mo^M j2. CONTACT PERSON (if different from applicant) SQ FT #of Stones # of Bedrooms tt of Bathrooms Name AddressAddress rtractor Dilialnt^rS^rttractor QSOwner City | Agent hf or Owner !]„ State/Zip Telephone tt Fax tt Name :4:v!::° PROPERTY OWNER Address City State/Zip Telephone # Address City State/Zip Telephone ttName 5 '^P|WIACTOR:-COMPANY NAME f ""'#• '"•'." -lifc- Ti° ,u'•.-•••. ''JftP (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exejnption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civjj/jsenalty of not men? thap-five hjyidred/dolla/sj$500]], Name State License tt Address License Class City State/Zip City Business License tt Designer Name Address City State/Zip Telephone State License tt _ 6- ";." WORKERS'' COMPENSAf ION ™V O'..; "• ...... ife' " iSltr ' : • '" "MtS^-^ • Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations O I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued Of I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Policy K Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) Q CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollarsJ^OO.OOO) J^addftion/tojthe y&\ of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney s fees ^^f^€^^^^l>f^^^ _ DATE ^-^^y^ ' ^ DECLARATIONIS : : C \ .' •'' S;-io '"''. '-"P " • I~' ' ' '•"'.' " '-. I hereby affirm that I am exempt from the Contractor's License Law for the following reason rj I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) n I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) l~l I am exempt under Section _ Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement d YES [JNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) _ 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) __ PROPERTY OWNER SIGNATURE DATE CQMPLEtlSr HIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY ' "S "H. '. ... Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? l~l YES l~l NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? fj YES Q NO Is the facility to be constructed within 1 ,000 feet of the outer boundary of a school site? H] YES [j] NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code) LENDER'S NAME _ LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE DATE WHITE File YELLOW Applicant PINK Finance Inspection List Permit* CB052057 Type RESDNTL RAD Date Inspection Item 03/06/2009 89 Final Combo 03/06/2009 89 02/18/200989 02/18/200989 09/05/2008 19 09/05/2008 29 09/05/2008 39 09/05/2008 49 05/02/2008 68 04/29/2008 68 02/20/2008 17 02/20/2008 18 01/29/2008 16 01/23/2008 84 01/09/2008 84 01/07/2008 18 12/27/2007 13 12/11/2007 13 12/11/2007 15 12/11/200784 05/16/2007 11 05/09/2007 1 1 02/28/2007 98 02/13/2007 22 02/05/2007 22 02/05/2007 34 01/31/2007 21 01/31/2007 23 01/29/2007 22 01/26/2007 22 01/26/2007 22 01/26/2007 98 01/26/2007 98 01/17/2007 11 01/17/2007 12 01/16/2007 11 01/16/2007 12 05/18/200621 05/18/200624 05/17/2006 21 Final Combo Final Combo Final Combo Final Structural Final Plumbing Final Electrical Final Mechanical Fireplace/Tie Straps Fireplace/Tie Straps Interior Lath/Drywall Exterior Lath/Drywall Insulation Rough Combo Rough Combo Exterior Lath/Drywall Shear Panels/HD's Shear Panels/HD's Roof/Reroof Rough Combo Ftg/Foundation/Piers Ftg/Foundation/Piers BMP Inspection Sewer/Water Service Sewer/Water Service Rough Electric Underground/Under Floor Gas/Test/Repairs Sewer/Water Service Sewer/Water Service Sewer/Water Service BMP Inspection BMP Inspection Ftg/Foundation/Piers Steel/Bond Beam Ftg/Foundation/Piers Steel/Bond Beam Underground/Under Floor Rough/Topout Underground/Under Floor Inspector Act Rl JM - JM PC PC PC PC JM JM JM JM JM JM JM JM PC JM JM JM JM JM DB JM JM JM JM JM JM JM JM JM JM JM JM JM JM JM JM JM Fl Rl CO NR PA PA NR AP CO AP AP AP AP CO CA AP CO AP we AP CO PI AP AP we we AP CA AP AP CO CO PA we CO CO AP we CO BAUM RESIDENCE-ADD 2101 SF 2ND STORY,ADD 3RD CAR GAR.REMODEL 17 Comments LIST ON SITE GAS ONLY RELEASE GAS METERS &ELEC 2 FIREPLACE FRAMES FIRESTOP & SHUT OFF VALVE OK TO INSULATE LIST ON SITE GLEN REAR ELEVATION SHEAR OK TO COVER CHANGES OK TO POUR STEEL / HDS / HARDY FRAME NOT PER PLAN SEE NOTICE IN FILE WATER ONLY removed filter backwash METERS TO HOUSE RAY NOTIFIED NOTIFIED SEE FND PLAN HOLD DOWNS MISSING @ ALL SHEAR EXPOSE ALL WASTE & REMOVE FOAM WRAP 05/17/2006 24 Rough/Topout JM WC Friday, March 06, 2009 Page 1 of 1 City of Carlsbad Bldg Inspection Request For 03/06/2009 Permit* CB052057 Title BAUM RESIDENCE-ADD 2101 SF 2ND Description STORY.ADD 3RD CAR GAR.REMODEL 1738 1ST FLOOR Inspector Assignment JM Type RESDNTL Sub Type RAD Job Address 1014 TULIP WY Suite Lot 0 Location APPLICANT PERRY BILL Owner BAUM RAYMOND C Remarks Phone 7605354659 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By GLEN Entered By CHRISTINE Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# PCR06116 ISSUED BAUM RES-REV ERROR-IN REAR SET, EXTEND 2ND STORY IN 1-RONT TO LINE UP PCR07040 ISSUED BAUM RESIDENCE, REVISE STRUCTURAL PAGES &CALCS Inspection History Date 02/18/2009 09/05/2008 09/05/2008 09/05/2008 09/05/2008 05/02/2008 04/29/2008 02/20/2008 02/20/2008 01/29/2008 01/23/2008 01/09/2008 Description 89 Final Combo 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical 68 Fireplace/Tie Straps 68 Fireplace/Tie Straps 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 16 Insulation 84 Rough Combo 84 Rough Combo Act CO NR PA PA NR AP CO AP AP AP AP CO Insp JM PC PC PC PC JM JM JM JM JM JM JM Comments LIST ON SITE GAS ONLY RELEASE GAS & ELEC METERS 2 FIREPLACE FRAMES FIRESTOP & SHUT OFF VALVE OK TO INSULATE LIST ON SITE City of Carlsbad Bldg Inspection Request For 09/05/2008 Permit* CB052057 Title BAUM RESIDENCE-ADD 2101 SF 2ND Description STORY.ADD 3RD CAR GAR.REMODEL 1738 1ST FLOOR Inspector Assignment JM Type RESDNTL Sub Type RAD Job Address 1014 TULIP WY Suite Lot 0 Location APPLICANT PERRY BILL Owner BAUM RAYMOND C Remarks Phone 7605354659 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By GLEN Entered By KATHY Act Comments PA Comments/Notices/Holds Date 05/02/2008 04/29/2008 02/20/2008 02/20/2008 01/29/2008 01/23/2008 01/09/2008 01/07/2008 12/27/2007 12/11/2007 12/11/2007 12/11/2007 Associated PCRs/CVs Original PC# PCR06116 ISSUED BAUM RES-REV ERROR-IN REAR SET, EXTEND 2ND STORY IN I;RONTTO LINE UP PCR07040 ISSUED 13AUM RESIDENCE, REVISE STRUCTURAL PAGES &CALCS Inspection History Description 68 Fireplace/Tie Straps 68 Fireplace/Tie Straps 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 16 Insulation 84 Rough Combo AP JM OK TO INSULATE 84 Rough Combo CO JM LIST ON SITE GLEN18 Exterior Lath/Drywall 13 Shear Panels/HD's 13 Shear Panels/HD's 15 Roof/Reroof 84 Rough Combo Act AP CO AP AP AP AP CO CA AP CO AP WC Insp JM JM JM JM JM JM JM JM PC JM JM JM Comments 2 FIREPLACE FRAMES FIRESTOP & SHUT OFF VALVE REAR ELEVATION SHEAR CHANGES OK TO COVER City of Carlsbad Bldg Inspection Request For 01/17/2007 Permit* CB052057 Title BAUM RESIDENCE-ADD 2101 SF 2ND Description STORY,ADD 3RD CAR GAR.REMODEL 1738 1ST FLOOR Inspector Assignment JM Type RESDNTL Sub Type RAD Job Address 1014 TULIP WY Suite Lot 0 Location OWNER BAUM RAYMOND C Owner BAUM RAYMOND C Remarks Phone 7605336797 Inspector Total Time CD Description 12 Steel/Bond Beam Act Comment Comments/Notices/Holds Requested By RAY Entered By CHRISTINE Associated PCRs/CVs Original PC# PCR06116 ISSUED BAUM RES-REV ERROR-IN REAR SET, EXTEND 2ND STORY IN I;RONT TO LINE UP .Inspection History Description Act Insp Comments CO JM HOLD DOWNS MISSING @ ALL SHEAR CO JM AP JM WC JM CO JM EXPOSE ALL WASTE & REMOVE FOAM WRAP WC JM Date 01/16/2007 11 Ftg/Foundation/Piers 01/16/2007 12 Steel/Bond Beam 05/18/2006 21 Underground/Under Floor 05/18/2006 24 Rough/Topout 05/17/2006 21 Underground/Under Floor 05/17/2006 24 Rough/Topout Jun 28 QGOB9i21pOPM HP LRSERJET FflX PP23 CERTI :IED INSPECTOR'S REPORT I AM ML1' SPECIAL CATECO 'hORIZED TO PERFORM NSPECTION IN TVE *V CHECKED D REINFORCED CONCRETE n PRE-STRESSED CONCRETE Q SE'NFORCsDA/IASONRY C STRUCT STEEL ASSEMBLY n REINFCR;:^ C/PSUM D CEE3 FOUNDATION D SPRAY-AP°'JED FIRE-PROOFING D OTHER JOB ADDRESS T fjlA 3UILOINC PERMIT NUMBER PLAN rILE NUMBER PROJECT IIAME ARC-IITEC~ CONST*PE GRADE ETC!DE5.SCURC: C? VlFCS ENGiNE^ V,AT L (MIX OEISlCN SE-3AR GRADE i WELD ^CC =~C 1 GENERAL CONTRACTOR LA3 RECslVINC 4 TESTING CONTR MAT L SAMPLES INSPECTION DATE G//t ( DETAILED LOCATION Oc ,VCRKINS?EC~ED TEST SAMPLEfTXKEN WCSK RE/ECTED ;O8 PROBLEMS PRCGSE53 SE,'/AS<£ ETC | REPORT OF INCUDES 'NFCR.WJION A3OLjr - A/.1OLNTJ OF MATERIAL PLACED OR WORK PERFORMED "RLJCT CONNECTIONS | WORK INSPECTED (WELDS MADE MT BOLTS TORQU6D) CHEC<SO ETC <il-V i -i I u/iVE NS?ECT;2 T-F. C~< LISTS? ^3C' S ' COMPL £-" WITH THE APPROVED ?L-^.NS SP:C f C^T E—iCNS OF THE BUILDING CC^E UNLESS CTK= P O Box 535 Lakeside, CA 92040 Tel (619) 443-1506 Fax (619) 443-1566 CERTIFIED INSPECTOR'S REPORT — p 1 AM AUTHORIZED TO PERFORM SPECIAL INSPECTION IN THE CATEGORY CHECKED D REINFORCED CONCRETE D PRE-STRESSED CONCRETE D REINFORCED MASONRY D STRUCT STEEL ASSEMBLY D REINFORCED GYPSUM D DEEP FOUNDATION D SPRAY APPLIED FIREPROOFING X. OTHER .S^V L JOB ADDRESS /g>/^ 72^ PROJECT NAME CAAL1 BUILDING PERMIT NUMBER PLAN FILE NUMBER ARCHITECT f/''i^ffr{ r \ *~ -^s f -i^ *- CONSTR MAT L (TYPE GRADE ETC )DESIGN STRENGTH SOURCE OF MFGR ENGINEER DESCRIBE /WAT L (MIX DEISIGN RE BAR GRADE & MFGR WELD ROD ETC )GENERAL CONTRACTOR CONTR DOING REPORTED WORK LAB" RECEIVING & TESTING CONTR MAT L SAMPLES INSPECTION DATE DETAILED LOCATION OF WORK INSPECTED TEST SAMPLES TAKEN WORK REJECTED JOB PROBLEMS PROGRESS REMARKS ETC REPORT OF INCLUDES INFORMATION ABOUT AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED STRUCT CONNECTIONS WORK INSPECTED (WELDS MADE M T BOLTS TORQUED) CHECKED ETC INSPECTORHEREBY CERTIFY THAT I HAVE INSPECTED THE WORK LISTED ABOVE AND THAT IT COMPLIES WITH THE APPROVED PLANS SPECIFICATIONS AND APPLICABLE SECTIONS OF THE BUILDING CODE UNLESS OTHER SIGNATURE . A/rcc Mcvrcrt Construction Inspections & Materials Testing Consulting 10444 Flanders Cove Ceil / Voice Matt (619) 261-0984 San Diego, CA. 92126 Fax (858) 893-3211 SPECIAL toBPEcrcNs UNLIMITEDINC. Job Mo.ForW«*En*ie REGISTERED INSPECTORS' DAILY REPORT f f TYPE OF NSPECT10N RBQUftSD •gf Reinforced Concrete Tl Poet Tansiooed ConcreteP Reinforced Masonry Structural Steal Assembly: StopWaldhg Fbfcf WtfclnQ am B FlroProodng j«*Add»-«»cvm^3/5/io TypeofSlnietUfe Architect 4 ^o?: // ^/rMatmM Description f*p* flrKto. **«»)OixiJixmr hspectorWNw.SwbOwtaBtor INSPECTION SUMMARY— LOCATIONS OF WORK INSPECTED, -sx ere. INCLUDES INFORMATION ABOUT AMOUNTS OF MATERIAL PUkCEDOKWOfX I ) tOBNT. NO'S OF TEST SAMPLES TAKEN, STRUCT, (XMNSCTIONS{WeLDMAOeH.r. CERTIFICATION OF COMPUANCE (HEREBY CERTFYTHATIHAVEOBSERVEOTOTHE BEST OF MY KNOWLEDGE AU. OF THE ABOVE REPORTED WORK UNLESS OIHERWICe NOTED. I HAVE FOUND THIS WORK TO SIGNATURE OF REGISTERED INSPECTOR DATE SPECIALTY CERT NO CITY/SAN OEGQf HMEW TMEOUT CVUN06R5 In addtton, 2 hour«ho«MJpirtnlinunfat)Bfc etmMUr»f< Appmvedby *#&!%&!*•,•:... Servin Engineering, Inc. 2382 Cam mo Vida Roble, Suite F Carlsbad, CA 92011 (760)931-1792, Fax (760)931-1892 Email nservin(ftjservin-engiueering com May 11,2007 Ray Baum 1014 Tuhp Street Carlsbad, CA 92011 RE Foundation revisions to approved plans Attached to this letter you will find two signed prints of the approved plans showing two revisions The first revision consists of changing out a Hardy Frame at the proposed office from a HF 9x48 to a HF 9x24 1 1/8 The second change consists of a foundation modification at the proposed master bath This change consists of having found a thick foundation system which is approximately 7 ft x 32" where a 32" x 32" x 18" footing was proposed The change will be to tie to the existing foundation with dowels as already set at the site and tied to the adjacent 12" x 18" x 32" pad I hope this answers any concerns your inspector has on the issues He can call my office for any related questions at his leisure Sincerely yours, NICK SERVIN, PE, Principal Engineer #33538 \\Servineng\data\john\D\Jobs\Bill Perry\Tuhp\FoundationRevl wpd IndependentInspection Special Inspection & NOT Isaiah E Gruhler (619) 203-7920 Project Name ,Q Inspection Report Project Address V(ZAM I v >V Architect Engineer Page of Contractor (xt\\ ^rvn C Permit* _ CtS File # DSA# Other v Report # ^•G>>S-~ INSPECTION Structural Steel Masonry Concrete Fireproofing 'f Other 5J.00X6V Other r ^ Other- ^ / Other *> Other MATERIAL SAMPLING QTY HS Bolts Pnsms Mortar/Grout Cone Cylinders Fireproof Other Other Other Other MATERIAL DESCRIPTION HS Bolts Cone PSI Grout PSI Mortar PSI / Steel Ju"W Kio(^ Elect /Wire Fireproof X Other e^^-r^-^- Other ^.^2_ /-7~r2_ INSPECTION CHECKLIST X Plans/Specs^/ ^^-7 A Clearances X. Positions ^ Sizes Laps Consolidation Torque Ft Lbs Other Other i\/v.^r -P M( !/• L^L 2- MM i-r fV tVx i YG> DouwJs CERTIFICATION OF COMPLIANCE All reported work unless otherwise noted, complies with approved plans specifications and applicable sections of the building codes This report covers the locations of the work mspjScted and does not constitute opinion or project control Inspector /IsaiafrE Gruhler cert SD#869 -\\1S3? Date ! 5/ /S "Day 2 Day 3 Day 4 DayS 5 Time Stop. ....... 1 I' Copies of report submitted to IndependentInspection Special Inspection & NOT Isaiah E Gruhler (619) 203-7920 Inspection Report Project Name i U>i ,/3 ^'SV CL- -s Protect Address \(2}l^-i "TV;>V> p VJiAr \oArchitect Engineer ^^>f"^C \ — >\ n Contractor C:Tl \e^\. C_r\ Vfb?r>o Page l of ( Report # ^Y>^ ( Permit* Cx'K^fS Z-QZ^T- —TSL- File# DSA# Other*%ss "INSPECTION /Structural Steel Masonry Concrete Fireproofing X Other f^^ty Other ' 6 Other Other Other MATERIAL SAMPLING QTY HS Bolts Pnsms Mortar/Grout Cone Cylinders Fireproof Other Other Other Other MATERIAL DESCRIPTION HS Bolts Cone PSI Grout PSI Mortar PSI Steel Elect /Wire Fireproof 1 V Other g" -^ % <2_ otner 6S<X >/c) *V S' INSPECTION CHECKLIST y Plans/Specs \/ Clearances \/ Positions X Sizes Laps Consolidation Torque Ft Lbs f? Other Other IS" '/-I (nru CERTIFICATION OF COMPLIANCE All reported work unless otherwise noted, complies with approved plans specifications and applicable sections of the building codes This report covers the locations of the work ins^ect^d and does not constitute opinion or project control Inspector^Isaiah E Gruhler Cert SD#869*Signature •^ /Date' _J_nsp Date ^ Day 1 j._Tjrne Stert_ { ^ LTimeStop.. | _X.t>c? Copies of report submitted to Day 3 Day 5 EsGil Corporation In Partnership with government for (BuiCding Safety DATE December 8, 2005 a APPLICANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO O5-2057 SET VI PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Baum Residence Addition and Remodel [XJ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff |~~| The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Aj Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Mr Bill Perry Telephone # In Person Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS Applicant to deliver to City By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC LOG trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 EsGil Corporation In Partnership with government for <BwC(fing Safety DATE November 1O, 20O5 a APPLICANT ftl JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 05-2057 SET V PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Baum Residence Addition/ Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list has been sent to Bill Perry 550 2nd Street Encmitas, Ca92024 Esgil Corporation staff did not advise the applicant that the plan check has been completed I Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Bill Perry Telephone # 760 809 8810 or 760 931 1792 Date contacted, >J, \H\eS(by |<A ) Fax # ? 760 931 1892 Mail Telephone \J Fax t/ln Person • REMARKS THIS TIME. ONLY THE STRUCTURAL DRAWINGS WERE SUBMITTED By Bert Domingo FOR BRIAN ZUPIGER Enclosures Esgil Corporation D GA D MB D EJ D PC 11/3/O5 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 4 Fax (858) 560-1576 Carlsbad 05-2057 November 1O, 2OO5 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PROJECT ADDRESS 1014 Tulip Way DATE PLAN RECEIVED BY ESGIL CORPORATION 11/3/05 REVIEWED BY Bert Domingo PLAN CHECK NO 05-2057 SET IV DATE RECHECK COMPLETED November 10, 2005 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfred before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of pnnts to B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes a No Carlsbad O5-2O57 November 10, 2005 • PLANS 1 Please make ail corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways THERE ARE A LOT OF HAND WRITTEN INFORMATION IN BALLPOINT INK ON THE SUBMITTED PLANS PLEASE MAKE THE CORRECTIONS ON THE ORIGINAL TRACINGS AS REQUESTED BEFORE SOME OF THE HANDWRITTEN INK INFORMATION SHOWN ON THE PLANS ARE DIFFICULT TO READ AND MAY CREATE MORE CONFUSION IN THE ALREADY CONFUSING CONSTRUCTION SITE. ALSO. IN ORDER TO HAVE AN APPROVED PLANS TO BE ISSUED TO PRINCIPALITIES UNIFORMfWITH THE SAME INFORMATION). PLEASE MAKE CORRECTIONS ON THE ORIGINAL TRACINGS AS REQUESTED BEFORE. a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, and (760) 602- 2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 3 Final plans, specifications and calculations shall be signed and sealed by the engineer or architect licensed by the State of California who is responsible for their preparation Specify expiration date of license (California Business and Professions Code) THIS WILL BE CHECKED WHEN ALL THE ITEMS BELOW ARE MET. 4 Clearly show the existing versus the proposed on each sheet The foundation details are for a new house Please incorporate details that show how the new construction will connect to the existing construction THE RESPONSE WAS S-1 BUT THE SAME SHEET DOES NOT SEEM TO SHOW ANY OF THE REQUESTED INFORMATION NO RESPONSE PROVIDED. 5 On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below UBC Section 106 3 2 PLEASE SHOW ON THE COVER SHEET AS REQUESTED NO RESPONSE PROVIDED. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with UBC Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS EXPANSION/EPOXY ANCHORS YES PER APPROVING REPORT Carlsbad O5-2O57 November 1O, 2005 7 On the cover sheet of the plans, specify any items that will have a deferred submittal (trusses, etc ) Additionally, provide the following note on the plans, per UBC Sec 106342 NO RESPONSE "Submittal documents for deferred submittal items shall be submitted to the architect or engineer of record, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official" • FIRE PROTECTION 8 When the valuation of a room addition exceeds $1,000, show permanently wired smoke detectors with battery backup in the new and existing construction, except that smoke detectors added at existing construction need only be battery powered UBC Section 310912 IT SEEMS NONE SHOWN ON SHEETS A1 & 2 AS RESPONDED THIS TIMET THERE IS NONE SHOWN ON THE 2ND FLOOR. a) Inside each bedroom b) Centrally located in corridor or area giving access to sleeping rooms c) On each story d) When sleeping rooms are upstairs, at the upper level in close proximity to the stair e) In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway NOTE Detectors shall sound an alarm audible in all sleeping areas of the unit UBC Section 3109 1 • EXITS, STAIRWAYS, AND RAILINGS 9 Provide stairway and landing details that are referenced to the floor plan UBC Sections 1003 3 3 _IT SEEMS NONE SHOWN AT THE STAIRS AS RESPONDED PLEASE PROVIDE STAIRS'DETAIL. a) Maximum rise is 7" and minimum run is 11" When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" minimum 10 Provide guardrail details that are referenced to the floor plan UBC Section 509 1 IT SEEMS NONE SHOWN ON SHEETS A4 AS RESPONDED AGAIN. PLEASE SHOW DETAILS. a) Shall be installed at all unenclosed floor openings b) Shall be installed at balconies more than 30" above grade or floor below c) Shall have a height of 36" d) Shall have connection details adequate to resist the horizontal force prescribed in UBC Table 16-B e) Openings between railings shall be less than 4" Carlsbad O5-2O57 November 1O, 2005 105 Provide details of winding stairway complying with Section 1003 3382 a) Minimum tread is 6 inches at anv point and minimum 9 inches at a point 12 inches from where the treads are narrowest. 11 Provide handrail details that are referenced to the floor plan UBC Section 1003 3 3 6 IT SEEMS NONE SHOWN ON SHEETS A4 AS RESPONDED AGAIN, PLEASE SHOW DETAILS. a) Handrails are required on each side of stairways having four or more stairs b) Stairways less than 44" wide or stairways serving one dwelling unit may have one handrail (if not open on both sides) c) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous d) The handgrip portion of all handrails shall be not less than 1-1/4 inches nor more than 2 inches in cross-sectional dimension Handrails projecting from walls shall have at least 1-1/2 inches between the wall and the handrail e) Ends of handrails shall be returned or shall have rounded terminations or bends f) Openings between railings shall be less than 4" The triangular openings formed by the riser, tread and bottom element of a handrail at a stair shall be less than 6" • GENERAL RESIDENTIAL REQUIREMENTS 12 In addition to the information shown on the plans, specify in the following locations should be of safety glazing material in accordance with UBC Section 2406 4 (see exceptions) PLEASE SEE ITEM 1 ABOVE. a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors See the Master bedroom IT SEEMS NONE SHOWN ON SHEETS A2 AS RESPONDED • ROOFING 13 Specify on the plans the following information for the roof and balcony materials, per UBC Section 106 3 3 IT SEEMS ICBO WAS INDICATED ON THE SHEET A4 BUT HARD TO READ. a) Manufacturer's name b) Material weight c) Product name/number d) ICBO approval number, or equal 15 Balconies and decks exposed to the weather and sealed underneath shall be sloped a minimum of % inch per foot for drainage UBC Section 1402 3 PLEASE SHOW THE REQUESTED INFORMATION ON THE BALCONIES/DECK. PLEASE SEE ITEM 1 ABOVE. Carlsbad 05-2O57 November 1O, 2005 GARAGE AND CARPORTS 17 Show a self-closing door, either 1-3/8" solid core or a listed 20 minute assembly, for openings between garage and dwelling Section 302 4 THE RESPONSE WAS A1 BUT SEEMS NONE SHOWN. PLEASE SEE ITEM 1 ABOVE. 18 All elements supporting floor above garage, including walls/beams/columns supporting floor joists, must have one-hour fire-resistive protection on the garage THE RESPONSE WAS A1 BUT SEEMS NONE SHQWN.side UBC Section 302 2 • FOUNDATION REQUIREMENTS 29 Provide calculations for mam vertical and horizontal framing member loads on the footings UBC Section 106 3 3 Based on the response more corrections may follow Drag collectors are required to transmit the tributary lateral load to the respective resisting elements Please submit analysis Any recommendations should be detailed on the plans and cross referenced to the framing plan PLEASE SEE LINES B, D, 2 , 3, ETC IT IS NOT CLEAR HOW THE DRAG TRUSS SYSTEM ALONG LINE 4 WOULD BE ATTACHED TO THE RESISTING ELEMENTS. AGAIN. PLEASE SEE LINES bT dT 2T 3. ETC. ft PLEASE SHOW CONNECTION DETAILS OF THE DRAG COLLECTORS TO THE RESPECTIVE RESISTING ELEMENTS PLEASE SEE ITEM e) ABOVE. h) PLEASE SHOW HOW THE LATERAL FLOOR LOAD ABOVE THE OFFICE AND BEDROOM, TO THE LEFT OF THE LIVING ROOM, WOULD BE SUPPORTED IN THE Y-Y DIRECTION THE RESPONSE SEEMS THE DETAILS 19. 15 & 16/S5 BUT. THE SAME DETAILS SEEMED NOT TO SHOW HOW THE REQUESTED INFORMATION WOULD BE ACCOMPLISHED. MAY NEED A DRAG SYSTEM. PLEASE SUBMIT ANALYSIS. I) IT SEEMS THAT THE RB2 DID NOT CONSIDER THE POINT LOAD FROM THE APEX OF THE RR1 PLEASE SUBMIT CALCULATIONS TO REFLECT THE POINT LOAD. k) PLEASE SHOW HOLDOWN DETAILS ON THE PLANS FOR THE SHEAR WALLS CONNECTION AT THE FLOOR LEVEL PLEASE CROSS REFERENCE THE SAME ON THE FRAMING PLAN. THE RESPONDED DETAIL C/S1 IS FOR THE FOUNDATION LEVEL. PLEASE SHOW DETAIL FOR THE 2N" FLOOR m) A COMPLETE PLAN CHECK WILL BE MADE. • FRAMING 30. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. Or submit a deferral. 32. Note on the plan that the structural consultant shall provide a letter of review for the truss plans and calculations with their submittal. Carlsbad O5-2O57 November 1O, 2O05 35. Detail truss layout for 30" x 30" attic access, if required for equipment in the attic and detail 30" x 30" clearance through truss webs. 22" x 30" may be used if the equipment size allows. Or submit a deferral. NO RESPONSE PROVIDED. • MECHANICAL (UNIFORM MECHANICAL CODE) THE NEW LOCATION OF THE FAU'S SHOULD BE ON AN 18" PLATFORM. WITH BARRIER FROM WHEEL IMPACT. • ELECTRICAL (NATIONAL ELECTRICAL CODE) 51 Show on the plans that receptacle outlet locations will comply with NEC Art 210-52(a) NONE SHOWN ON SHEET A1 AS RESPONDED. 52 For a single-family dwelling unit, show that at least one receptacle outlet accessible at grade level will be installed outdoors at the front and back of the dwelling NEC Art 210- 52 (e) This receptacle must be GFCI protected NONE SHOWN ON SHEET A2 AS RESPONDED. 53 Show on the plans that countertop receptacle outlets in kitchens and dining areas of dwelling units a receptacle outlet shall be installed at each counter space wider than 12 inches Receptacles shall be installed so that no point along the wall line is more than 24 inches measured horizontally from a receptacle outlet in that space Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces NEC Art 210-52(c) THE RESPONSE WAS HARD TO READ!!!! 54 Per NEC Art 210-11(c)3, note on the plans that bathroom circuiting shall be either SEEMS NO RESPONSE A 20 ampere circuit dedicated to each bathroom, or At least one 20 ampere circuit supplying only bathroom receptacle outlets 55 Show on the plans a wall receptacle adjacent to each lavatory in the bathroom NEC Art 210-52(d) PLEASE SEE THE OTHER LAVATORIES 56. Show on the plan that receptacle outlets in hallways 10 feet or more in length shall have at least one receptacle outlet. NEC Art. 210-52fh). 58. All bedroom branch circuits now require arc fault protection. Note clearly on the plans that "Bedroom branch circuits will be arc fault circuit protected." NEC Art MO-1 Carlsbad O5-2057 November 1O, 2OO5 • ENERGY CONSERVATION 64 Provide plans, calculations and worksheets to show compliance with current energy standards. THE ENERGY CALCULATIONS SEEM TO INDICATE THAT THE EXISTING ENVELOPE SHOULD COMPLY ALSO TO THE RECOMMENDATIONS REFLECTED IN THE ANALYSIS. THIS INTENTIONS/INDICATIONS SHOULD BE REFLECTED ON THE COVER SHEET. ALSO. PLEASE SEE ITEM 69 BELOW 65. The regulations require a properly completed and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. THE INDEX SHOWS THE TITLE 24 ON SHEET A-6 BUT NOT SUBMITTED. 66. Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and bathrooms (containing a tub or shower). 67. Note on the plans: "The manufactured windows shall have a label attached certified by the National Fenestration Rating Council fNFRC) and showing compliance with the energy calculations." • MISCELLANEOUS 68. Please reconcile the drawing index with the sheets of the plans. 69. Please complete the building data To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation Thank you EsGil Corporation In tfartnersdip with government for (BuikCing Safety DATE October 25, 2005 CLAPPUCPUCANT RIS^ JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 05-2057 SET IV PROJECT ADDRESS- 1014 Tulip Way PROJECT NAME Baum Residence Addition/Remodel I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I | The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck • The applicant's copy of the check list has been sent to: Bill Perry 550 2nd Street Encmitas, Ca92024 I | Esgil Corporation staff did not advise the applicant that the plan check has been completed. • Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted BiiyPerry Telephone # 760 809 8810 or 760 931 1 792 Date contacted jt)fefo^(by t/V ) Fax# ? 760 931 1892 Mail Telephone Fax In Person • REMARKS AGAIN THE RESUBMITTED PACKAGE(SLIP SHEETED) DID NOT SEEM TO HAVE INCLUDED A RESPONSE FOR EACH ITEM OF THE PREVIOUS CORRECTION(EXCEPT THE STRUCTURAL, PLEASE SEE THE CORRECTIONS BELOW) DESPITE OF HAVING NO RESPONSE SUBMITTED, A CURSORY REVIEW ON THE PLANS WERE MADE ANYWAY BUT, SEEMS NO APPRECIABLE CHANGE ON THE PLANS TO REFLECT ANY EFFORT THAT WOULD HAVE BEEN MADE BY THE ARCHITECT/ENGINEER TO COMMUNICATE IN ORDER TO ATTAIN THE ULTIMATE GOAL OF THE 97 UBC IN THE INTEREST OF PUBLIC SAFETY AND HEALTH AND TO FACILITATE THE PERMIT PROCESS, PLEASE EXERT MORE EFFORT TO ATTAIN THE END WE CAN NOT CHECK THE PLANS WITHOUT PROVIDING US THE REQUESTED INFORMATION AS EMBODIED IN THE CORRECTION LIST BELOW. PLEASE SEE ITEM 1 By Bert Domingo FOR BRIAN ZUPIGER Enclosures Esgil Corporation D GA D MB D EJ D PC 10/17/05 9320 Chesapeake Drive, Suite 208 + San Diego, California 92 123 * (858)560-1468 * Fax (858) 560-1576 Carlsbad 05-2O57 October 25, 2O05 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PROJECT ADDRESS 1O14 Tulip Way DATE PLAN RECEIVED BY ESGIL CORPORATION 10/17/05 REVIEWED BY Bert Domingo PLAN CHECK NO 05-2O57 SET IV DATE RECHECK COMPLETED October 25, 2O05 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes a NO Carlsbad O5-2O57 October 25, 2005 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways THERE ARE A LOT OF HAND WRITTEN INFORMATION IN BALLPOINT INK ON THE SUBMITTED PLANS PLEASE MAKE THE CORRECTIONS ON THE ORIGINAL TRACINGS AS REQUESTED BEFORE SOME OF THE HANDWRITTEN INK INFORMATION SHOWN ON THE PLANS ARE DIFFICULT TO READ AND MAY CREATE MORE CONFUSION IN THE ALREADY CONFUSING CONSTRUCTION SITE. ALSO. IN ORDER TO HAVE AN APPROVED PLANS TO BE ISSUED TO PRINCIPALITIES UNIFORMfWITH THE SAME INFORMATION!. PLEASE MAKE CORRECTIONS ON THE ORIGINAL TRACINGS AS REQUESTED BEFORE. a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, and (760) 602- 2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engmeenng and Fire Departments b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE. Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 3 Final plans, specifications and calculations shall be signed and sealed by the engineer or architect licensed by the State of California who is responsible for their preparation Specify expiration date of license (California Business and Professions Code) THIS WILL BE CHECKED WHEN ALL THE ITEMS BELOW ARE MET. 4 Clearly show the existing versus the proposed on each sheet The foundation details are for a new house Please incorporate details that show how the new construction will connect to the existing construction THE RESPONSE WAS S-1 BUT THE SAME SHEET DOES NOT SEEM TO SHOW ANY OF THE REQUESTED INFORMATION. NO RESPONSE PROVIDED. 5 On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below UBC Section 106 3 2 PLEASE SHOW ON THE COVER SHEET AS REQUESTED NO RESPONSE PROVIDED. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with UBC Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS EXPANSION/EPOXY ANCHORS YES PER APPROVING REPORT Carlsbad 05-2057 October 25, 2005 7. On the cover sheet of the plans, specify any items that will have a deferred submittal (trusses, etc ) Additionally, provide the following note on the plans, per UBC Sec 106342 NO RESPONSE "Submittal documents for deferred submittal items shall be submitted to the architect or engineer of record, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in genera) conformance with the design of the building The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official" • FIRE PROTECTION 8 When the valuation of a room addition exceeds $1,000, show permanently wired smoke detectors with battery backup in the new and existing construction, except that smoke detectors added at existing construction need only be battery powered UBC Section 310912 IT SEEMS NONE SHOWN ON SHEETS A1 & 2 AS RESPONDED THIS TIME. THERE IS NONE SHOWN ON THE 2NP FLOOR. a) Inside each bedroom b) Centrally located in corridor or area giving access to sleeping rooms c) On each story d) When sleeping rooms are upstairs, at the upper level in close proximity to the stair e) In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway NOTE Detectors shall sound an alarm audible in all sleeping areas of the unit UBC Section 3109 1 • EXITS, STAIRWAYS, AND RAILINGS 9 Provide stairway and landing details that are referenced to the floor plan UBC Sections 1003 3 3 _IT SEEMS NONE SHOWN AT THE STAIRS AS RESPONDED PLEASE PROVIDE STAIRS'DETAIL. a) Maximum rise is 7" and minimum run is 11" When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" minimum 10 Provide guardrail details that are referenced to the floor plan UBC Section 509 1 IT SEEMS NONE SHOWN ON SHEETS A4 AS RESPONDED AGAIN. PLEASE SHOW DETAILS. a) Shall be installed at all unenclosed floor openings b) Shall be installed at balconies more than 30" above grade or floor below c) Shall have a height of 36" d) Shall have connection details adequate to resist the horizontal force prescribed in UBC Table 16-B e) Openings between railings shall be less than 4" Carlsbad 05-2057 October 25, 2O05 105 Provide details of winding stairway complying with Section 1003 3382 a) Minimum tread is 6 inches at anv point and minimum 9 inches at a point 12 inches from where the treads are narrowest. 11 Provide handrail details that are referenced to the floor plan UBC Section 1003 3 3 6 IT SEEMS NONE SHOWN ON SHEETS A4 AS RESPONDED AGAIN. PLEASE SHOW DETAILS. a) Handrails are required on each side of stairways having four or more stairs b) Stairways less than 44" wide or stairways serving one dwelling unit may have one handrail (if not open on both sides) c) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous d) The handgrip portion of all handrails shall be not less than 1-1/4 inches nor more than 2 inches in cross-sectional dimension Handrails projecting from walls shall have at least 1-1/2 inches between the wall and the handrail e) Ends of handrails shall be returned or shall have rounded terminations or bends f) Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a handrail at a stair shall be less than 6" • GENERAL RESIDENTIAL REQUIREMENTS 12 In addition to the information shown on the plans, specify in the following locations should be of safety glazing material in accordance with UBC Section 2406 4 (see exceptions) PLEASE SEE ITEM 1 ABOVE. a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than ward robe doors See the Master bedroom • IT SEEMS NONE SHOWN ON SHEETS A2 AS RESPONDED • ROOFING 13 Specify on the plans the following information for the roof and balcony materials, per UBC Section 10633 IT SEEMS ICBO WAS INDICATED ON THE SHEET A4 BUT HARD TO READ. a) Manufacturer's name b) Material weight c) Product name/number d) ICBO approval number, or equal 15 Balconies and decks exposed to the weather and sealed underneath shall be sloped a minimum of V4 inch per foot for drainage UBC Section 1402 3 PLEASE SHOW THE REQUESTED INFORMATION ON THE BALCONIES/DECK. PLEASE SEE ITEM 1 ABOVE. Carlsbad O5-2057 October 25, 20O5 • GARAGE AND CARPORTS 17. Show a self-closing door, either 1-3/8" solid core or a listed 20 minute assembly, for openings between garage and dwelling Section 302 4 THE RESPONSE WAS A1 BUT SEEMS NONE SHOWN. PLEASE SEE ITEM 1 ABOVE. 18 All elements supporting floor above garage, including walls/beams/columns supporting floor joists, must have one-hour fire-resistive protection on the garage THE RESPONSE WAS A1 BUT SEEMS NONE SHOWN.side UBC Section 302 2 The structural plans are incomplete and vague. The following corrections are general in nature and based on the response more corrections may follow. For a complete review, submit construction drawings that reflect the scope of work. • FOUNDATION REQUIREMENTS THE ITEMS 24 -32 BELOW WERE RESPONDED TO BUT NO REVISED PLANS AS RESPONDED WERE SUBMITTED. 24 If the soils engineer recommends that he/she review the foundation excavations note on the foundation plan that PLEASE SHOW THE REQUESTED NOTE ON THE FOUNDATION PLAN. a) "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that b) The building pad was prepared in accordance with the soils report, c) The utility trenches have been properly backfilled and compacted, and d) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report" 25. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents. 29 Provide calculations for mam vertical and horizontal framing member loads on the footings UBC Section 106 3 3 Based on the response more corrections may follow a) PLEASE SHOW CONNECTION DETAIL FOR THE APEX OF THE RR1 RAFTERS ABOVE THE BEAM RB2 ABOVE THE STAIRS. b) PLEASE SHOW ON THE FLOOR PLANS WHERE THE SECTIONS CUT WERE Carlsbad O5-2057 October 25, 2O05 C) THE ROOF SYSTEM REFLECTED ON THE SHEET S-3 ABOVE THE MASTER'S BATH IS NOT CLEAR HOW IT WOULD BE FRAMED. IT SHOWS RR1 AND HIP JACKS. d) PLEASE SHOW SHEAR TRANSFER DETAIL ON THE PLANS FROM THE DIAPHRAGMS TO THE INTERIOR SHEAR WALLS. PLEASE CROSS REFERENCE THE SAME TO THE FRAMING PLANS. e) Drag collectors are required to transmit the tributary lateral load to the respective resisting elements. Please submit analysis. Anv recommendations should be detailed on the plans and cross referenced to the framing plan. PLEASE SEE LINES B. D. 2 . 3. ETC. f) PLEASE SHOW CONNECTION DETAILS OF THE DRAG COLLECTORS TO THE RESPECTIVE RESISTING ELEMENTS. 9) PLEASE SIZE OF THE STUDS AT THE EXTERIOR WALLS OF THE STAIRS. h) PLEASE SHOW HOW THE LATERAL FLOOR LOAD ABOVE THE OFFICE AND BEDROOM. TO THE LEFT OF THE LIVING ROOM. WOULD BE SUPPORTED IN THE Y-Y DIRECTION. i) IT SEEMS THAT THE RB2 DID NOT CONSIDER THE POINT LOAD FROM THE APEX OF THE RR1. j) THE SOILS REPORT RECOMMENDED 24" DEEP FOR THE PAD FOOTINGS BUT THE SCHEDULE SHOWS DIFFERENTLY. k) PLEASE SHOW HOLDQWN DETAILS ON THE PLANS FOR THE SHEAR WALLS CONNECTION AT THE FLOOR LEVEL. PLEASE CROSS REFERENCE THE SAME ON THE FRAMING PLAN. I) PLEASE SHOW HOW THE SHEAR LOAD ALONG LINES 5 & 6 AT THE ROOF LEVEL WOULD BE TRANSFERRED THRU TO THE RESISTING ELEMENTS. PLEASE SEE TOWARDS LINES 6.1 & 6.5 RESPECTIVELY. ml A COMPLETE PLAN CHECK WILL BE MADE. • FRAMING 30. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. Or submit a deferral. Carlsbad O5-2O57 October 25, 2OO5 31 Show draglines and girder trusses on the plans FOR THE DRAG TRUSSES TO BE DESIGNED ACCORDINGLY. THE DESIGNED DRAG FORCE SHOULD BE SHOWN RESPECTIVELY. 32. Note on the plan that the structural consultant shall provide a letter of review for the truss plans and calculations with their stibmittal. 35. Detail truss layout for 30" x 30" attic access, if required for equipment in the attic and detail 30" x 30" clearance through truss webs, 22" x 30" mav be used if the equipment size allows. Or submit a deferral. NO RESPONSE PROVIDED. • MECHANICAL (UNIFORM MECHANICAL CODE) THE NEW LOCATION OF THE FAU'S SHOULD BE ON AN 18" PLATFORM. WITH BARRIER FROM WHEEL IMPACT. • ELECTRICAL (NATIONAL ELECTRICAL CODE) 51 Show on the plans that receptacle outlet locations will comply with NEC Art 210-52(a) NONE SHOWN ON SHEET A1 AS RESPONDED. 52 For a single-family dwelling unit, show that at least one receptacle outlet accessible at grade level will be installed outdoors at the front and back of the dwelling NEC Art 210- 52 (e) This receptacle must be GFCI protected NONE SHOWN ON SHEET A2 AS RESPONDED. 53 Show on the plans that countertop receptacle outlets in kitchens and dining areas of dwelling units a receptacle outlet shall be installed at each counter space wider than 12 inches Receptacles shall be installed so that no point along the wall line is more than 24 inches measured horizontally from a receptacle outlet in that space Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate countertop spaces NEC Art 210-52(c) THE RESPONSE WAS HARD TO READ!!!! 54 Per NEC Art 210-11(c)3, note on the plans that bathroom circuiting shall be either SEEMS NO RESPONSE A 20 ampere circuit dedicated to each bathroom, or At least one 20 ampere circuit supplying only bathroom receptacle outlets 55 Show on the plans a wall receptacle adjacent to each lavatory in the bathroom NEC Art 210-52(d) PLEASE SEE THE OTHER LAVATORIES 56. Show on the plan that receptacle outlets in hallways 10 feet or more in length shall have at least one receptacle outlet. NEC Art. 210-52fh^. Carlsbad O5-2O57 October 25, 2O05 58. AM bedroom branch circuits now require arc fault protection. Note clearly on the plans that "Bedroom branch circuits will be arc fault circuit protected." NEC Art. 210-12fbl. • ENERGY CONSERVATION 64 Provide plans, calculations and worksheets to show compliance with current energy standards. THE ENERGY CALCULATIONS SEEM TO INDICATE THAT THE EXISTING ENVELOPE SHOULD COMPLY ALSO TO THE RECOMMENDATIONS REFLECTED IN THE ANALYSIS. THIS INTENTIONS/INDICATIONS SHOULD BE REFLECTED ON THE COVER SHEET. ALSO. PLEASE SEE ITEM 69 BELOW~ 65. The regulations require a properly completed and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. THE INDEX SHOWS THE TITLE 24 ON SHEET A-6 BUT NOT SUBMITTED. 66. Provide fluorescent general lighting (40 lumens per watt minimum) in kitchenfsl and bathrooms (containing a'tub or shower). 67. Note on the plans: "The manufactured windows shall have a label attached certified bv the National Fenestration Rating Council (NFRC) and showing compliance with the energy calculations." • MISCELLANEOUS 68. Please reconcile the drawing index with the sheets of the plans. 69. Please complete the building data. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation Thank you EsGil Corporation In fartnersntp with government for (Ruihfing Safety DATE- August 23, 2005 a APPLICANT QCJURJ^ JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 05-2057 SET II PROJECT ADDRESS 1014 Tulip Way * PROJECT NAME Baum Residence Addition/Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Bill Perry 550 2nd Street Encmitas, Ca92024 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Bill Perry Telephone # 760 809 8810 or 760 931 1792 Date contacted fr /2S/o5(by ^ ) Fax # ? 760931 1892 Mail.—-Telephone*^ Faxi^ In Person REMARKS By Bert Domingo FOR BRIAN ZUPIGER Enclosures Esgil Corporation D GA D MB D EJ D PC 8/16/05 tmsmtl dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad 05-2057 August 23, 2005 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PROJECT ADDRESS 1O14 Tulip Way DATE PLAN RECEIVED BY ESGIL CORPORATION 8/16/05 REVIEWED BY Bert Domingo PLAN CHECK NO 05-2O57 SET II DATE RECHECK COMPLETED August 23, 2005 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo Carlsbad O5-2O57 August 23, 2005 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways THERE ARE A LOT OF HAND WRITTEN INFORMATION IN BALLPOINT INK ON THE SUBMITTED PLANS. PLEASE MAKE THE CORRECTIONS ON THE ORIGINAL TRACINGS AS REQUESTED BEFORE. a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, and (760) 602- 2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 3 Final plans, specifications and calculations shall be signed and sealed by the engineer or architect licensed by the State of California who is responsible for their preparation Specify expiration date of license (California Business and Professions Code). THIS WILL BE CHECKED WHEN ALL THE ITEMS BELOW ARE MET. 4 Clearly show the existing versus the proposed on each sheet The foundation details are for a new house Please incorporate details that show how the new construction will connect to the existing construction. THE RESPONSE WAS S-1 BUT THE SAME SHEET DOES NOT SEEM TO SHOW ANY OF THE REQUESTED INFORMATION. 5 On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below UBC Section 106 3 2. PLEASE SHOW ON THE COVER SHEET AS REQUESTED. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with UBC Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS EXPANSION/EPOXY ANCHORS YES PER APPROVING REPORT 6 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review UBC Section 106 3 5 Please complete parts 1, 2 & 3 of the attached form and resubmit. THE RESPONSE WAS ATTACHED BUT SEEMS NOT SUBMITTED WITH THIS PACKAGE. Carlsbad O5-2057 August 23, 2005 7 On the cover sheet of the plans, specify any items that will have a deferred submittal (trusses, etc ) Additionally, provide the following note on the plans, per UBC Sec 106342 NO RESPONSE "Submittal documents for deferred submittal items shall be submitted to the architect or engineer of record, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building The deferred submrttal items shall NOT be installed until their design and submittal documents have been approved by the building official" • FIRE PROTECTION 8 When the valuation of a room addition exceeds $1,000, show permanently wired smoke detectors with battery backup in the new and existing construction, except that smoke detectors added at existing construction need only be battery powered UBC Section 310912 IT SEEMS NONE SHOWN ON SHEETS A1 & 2 AS RESPONDED a) Inside each bedroom b) Centrally located in corridor or area giving access to sleeping rooms c) On each story d) When sleeping rooms are upstairs, at the upper level in close proximity to the stair e) In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway NOTE Detectors shall sound an alarm audible in aj| sleeping areas of the unit UBC Section 3109 1 • EXITS, STAIRWAYS, AND RAILINGS 9 Provide stairway and landing details that are referenced to the floor plan UBC Sections 1003 3 3- IT SEEMS NONE SHOWN AT THE STAIRS AS RESPONDED a) Maximum rise is 7" and minimum run is 11" When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" minimum 10 Provide guardrail details that are referenced to the floor plan UBC Section 509 1 IT SEEMS NONE SHOWN ON SHEETS A4 AS RESPONDED a) Shall be installed at all unenclosed floor openings b) Shall be installed at balconies more than 30" above grade or floor below c) Shall have a height of 36" d) Shall have connection details adequate to resist the horizontal force prescnbed in UBC Table 16-B e) Openings between railings shall be less than 4" Carlsbad 05-2057 August 23, 2005 11 Provide handrail details that are referenced to the floor plan UBC Section 1003 3 3 6 IT SEEMS NONE SHOWN ON SHEETS A4 AS RESPONDED a) Handrails are required on each side of stairways having four or more stairs b) Stairways less than 44" wide or stairways serving one dwelling unit may have one handrail (if not open on both sides) c) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous d) The handgrip portion of all handrails shall be not less than 1-1/4 inches nor more than 2 inches in cross-sectional dimension Handrails projecting from walls shall have at least 1-1/2 inches between the wall and the handrail e) Ends of handrails shall be returned or shall have rounded terminations or bends f) Openings between railings shall be less than 4" The triangular openings formed by the riser, tread and bottom element of a handrail at a stair shall be less than 6" • GENERAL RESIDENTIAL REQUIREMENTS 12 In addition to the information shown on the plans, specify in the following locations should be of safety glazing material in accordance with UBC Section 2406 4 (see exceptions) a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors See the Master bedroom IT SEEMS NONE SHOWN ON SHEETS A2 AS RESPONDED • ROOFING 13 Specify on the plans the following information for the roof and balcony materials, per UBC Section 106 3 3 IT SEEMS ICBO WAS INDICATED ON THE SHEET A4 BUT HARD TO READ. a) Manufacturer's name b) Material weight c) Product name/number d) ICBO approval number, or equal 15 Balconies and decks exposed to the weather and sealed underneath shall be sloped a minimum of % inch per foot for drainage UBC Section 1402 3. PLEASE SHOW THE REQUESTED INFORMATION ON THE BALCONIES/DECK. • GARAGE AND CARPORTS 17 Show a self-closing door, either 1-3/8" solid core or a listed 20 minute assembly, for openings between garage and dwelling Section 302 4 THE RESPONSE WAS A1 BUT SEEMS NONE SHOWN. Carlsbad 05-2057 August 23, 2005 18 All elements supporting floor above garage, including walls/beams/columns supporting floor joists, must have one-hour fire-resistive protection on the garage THE RESPONSE WAS A1 BUT SEEMS NONE SHOWN.side UBC Section 302 2 The structural plans are incomplete and vague. The following corrections are general in nature and based on the response more corrections may follow. For a complete review, submit construction drawings that reflect the scope of work. • FOUNDATION REQUIREMENTS 24 If the soils engineer recommends that he/she review the foundation excavations note on the foundation plan that PLEASE SHOW THE REQUESTED NOTE ON THE FOUNDATION PLAN. a) "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that b) The building pad was prepared in accordance with the soils report, c) The utility trenches have been properly backfilled and compacted, and d) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report" 25. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents. 29 Provide calculations for main vertical and horizontal framing member loads on the footings UBC Section 106 3 3 Based on the response more corrections may follow a) PLEASE SHOW CONNECTION DETAIL FOR THE APEX OF THE RR1 RAFTERS ABOVE THE BEAM RB2 ABOVE THE STAIRS. b) PLEASE SHOW ON THE FLOOR PLANS WHERE THE SECTIONS CUT WERE TAKEN. c) THE ROOF SYSTEM REFLECTED ON THE SHEET S-3 ABOVE THE MASTER'S BATH IS NOT CLEAR HOW IT WOULD BE FRAMED. IT SHOWS RR1 AND HIP d) PLEASE SHOW SHEAR TRANSFER DETAIL ON THE PLANS FROM THE DIAPHRAGMS TO THE INTERIOR SHEAR WALLS. PLEASE CROSS REFERENCE THE SAME TO THE FRAMING PLANS. Carlsbad O5-2O57 August 23, 20O5 e) Drag collectors are required to transmit the tributary lateral load to the respective resisting elements. Please submit analysis. Anv recommendations should be detailed on the plans and cross referenced to the framing plan. PLEASE SEE LINES B. D. 2 . 3. ETC. f) PLEASE SHOW CONNECTION DETAILS OF THE DRAG COLLECTORS TO THE RESPECTIVE RESISTING ELEMENTS. g) PLEASE SIZE OF THE STUDS AT THE EXTERIOR WALLS OF THE STAIRS. h) PLEASE SHOW HOW THE LATERAL FLOOR LOAD ABOVE THE OFFICE AND BEDROOM. TO THE LEFT OF THE LIVING ROOM. WOULD BE SUPPORTED IN THE Y-Y DIRECTION. i) IT SEEMS THAT THE RB2 DID NOT CONSIDER THE POINT LOAD FROM THE APEX OF THE RR1. j) THE SOILS REPORT RECOMMENDED 24" DEEP FOR THE PAD FOOTINGS BUT THE SCHEDULE SHOWS DIFFERENTLY. k) PLEASE SHOW HOLDOWN DETAILS ON THE PLANS FOR THE SHEAR WALLS CONNECTION AT THE FLOOR LEVEL. PLEASE CROSS REFERENCE THE SAME ON THE FRAMING PLAN. I) PLEASE SHOW HOW THE SHEAR LOAD ALONG LINES 5 & 6 AT THE ROOF LEVEL WOULD BE TRANSFERRED THRU TO THE RESISTING ELEMENTS. PLEASE SEE TOWARDS LINES 6.1 & 6.5 RESPECTIVELY. ml A COMPLETE PLAN CHECK WILL BE MADE. • FRAMING 30. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. Or submit a deferral. 31 Show draglines and girder trusses on the plans FOR THE DRAG TRUSSES TO BE DESIGNED ACCORDINGLY. THE DESIGNED DRAG FORCE SHOULD BE SHOWN RESPECTIVELY. 32. Note on the plan that the structural consultant shall provide a letter of review for the truss plans and calculations with their submittal. Carlsbad 05-2057 August 23, 2005 34 Include the FAD and platform on in the truss layout and calculations Or submit a deferral THE RESPONSE WAS DEFERRAL. PLEASE CLARIFY. 35. Detail truss layout for 30" x 30" attic access, if required for equipment in the attic and detail 30" x 30" clearance through truss webs. 22" x 30" mav be used if the equipment size allows. Or submit a deferral. NO RESPONSE PROVIDED. • MECHANICAL (UNIFORM MECHANICAL CODE) • NONE WAS RESPONDED TO. 40. Show the location, type and size (BTU's) of all heating and cooling appliances or systems. Based on the response more corrections may follow. 41. Show source of combustion air to furnace per Chapter 7 UMC. Specify the location and sizes of both of the combustion air openings. 42. Show minimum 30" deep unobstructed working space in front of furnace. UMC Section 903. 43. Note that passageway to the mechanical equipment in the attic shall be unobstructed and have continuous solid flooring not less than 24 inches wide, not more than 20 feet in length through the attic. UMC Section 908.0. 44. Show a permanent electrical receptacle outlet and lighting fixture controlled by a switch located at the entrance for furnaces located in an attic space. UMC Section 908.0. / 45. Note on the plans that the FAU closet or alcove must be 12 inches wider than the furnace or furnaces being installed. UMC Section 904.1. 46. Provide installation details for furnaces located on the roof or the building exterior, UMC Section 910.0. 47. The maximum length of a clothes dryer duct is 14 feet with (two) 90° elbows. All terminations shall be 3' from any opening in a building. UMC Section 504.2.2. • ELECTRICAL (NATIONAL ELECTRICAL CODE) 51 Show on the plans that receptacle outlet locations will comply with NEC Art. 210-52(a) NONE SHOWN ON SHEET A1 AS RESPONDED. 52 For a single-family dwelling unit, show that at least one receptacle outlet accessible at grade level will be installed outdoors at the front and back of the dwelling NEC Art 210- 52 (e) This receptacle must be GFCI protected NONE SHOWN ON SHEET A2 AS RESPONDED. Carlsbad 05-2057 August 23, 2005 53 Show on the plans that countertop receptacle outlets in kitchens and dining areas of dwelling units a receptacle outlet shall be installed at each counter space wider than 12 inches Receptacles shall be installed so that no point along the wall line is more than 24 inches measured horizontally from a receptacle outlet in that space Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces NEC Art 210-52(c) THE RESPONSE WAS HARD TO READ!!!! 54 Per NEC Art 210-11(c)3, note on the plans that bathroom circuiting shall be either SEEMS NO RESPONSE A 20 ampere circuit dedicated to each bathroom, or At least one 20 ampere circuit supplying only bathroom receptacle outlets 55 Show on the plans a wall receptacle adjacent to each lavatory in the bathroom NEC Art 210-52(d) PLEASE SEE THE OTHER LAVATORIES 56. Show on the plan that receptacle outlets in hallways 10 feet or more in length shall have at least one receptacle outlet. NEC Art. 210-52(h). 58. All bedroom branch circuits now require arc fault protection. Note clearly on the plans that "Bedroom branch circuits will be arc fault circuit protected." NEC Art. 210-12fbl • ENERGY CONSERVATION 64 Provide plans, calculations and worksheets to show compliance with current energy standards. THE ENERGY CALCULATIONS SEEM TO INDICATE THAT THE EXISTING ENVELOPE SHOULD COMPLY ALSO TO THE RECOMMENDATIONS REFLECTED IN THE ANALYSIS. THIS INTENTIONS/INDICATIONS SHOULD BE REFLECTED ON THE COVER SHEET. ALSO. PLEASE SEE ITEM 69 BELOW 65. The regulations require a properly completed and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. 66. Provide fluorescent general lighting (40 lumens per watt minimum) in kitchenfs) and bathrooms (containing a tub or shower). 67. Note on the plans: "The manufactured windows shall have a label attached certified bv the National Fenestration Rating Council (NFRC1 and showing compliance with the energy calculations." • MISCELLANEOUS 68. Please reconcile the drawing index with the sheets of the plans. 69. Please complete the building data. Carlsbad O5-2O57 August 23, 2OO5 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation Thank you Carlsbad 05-2057 August 23, 2005 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No 05-2057 Job Address or Legal Description 1014 Tulip Way Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect. The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department. Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet. (over) Carlsbad 05-2057 August 23, 2005 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: 1014 Tulip Way PLAN CHECK NUMBER: 05-2057 OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above Engineer's/Architect t Seal & Signature Hare Signed 1. List of work requiring special inspection: D Field Welding HH Structural Concrete Over 2500 PSI n Prestressed Concrete D Structural Masonry D High Strength Bolting D Expansion/Epoxy Anchors D Sprayed-On Fireproofing D Designer Specified 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: A. B. C. 3. Duties of the special inspectors for the work listed above: A. B. C. Special inspectors shall check in with the City and present their credentials for approval pnor to beginning work on the job site EsGii Corporation In Partnership with government for <Bwhfing Safety DATE June 17, 2005 a APPLICANT JURISDICTION Carlsbad Q PDS^REVIEWER a FILE PLAN CHECK NO 05-2057 SET I PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Baum Residence Addition/ Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck • The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I | The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person I The applicant's copy of the check list has been sent to Bill Perry 550 2nd Street Encmitas, Ca92024 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Bill Perry Telephone # 760 809 8810 or 760 931 1792 Date contacted ^Ufo5"(by fc~ ) Fax# ^760)934=t89g- ^fr"?- Mail -^Telephone */ Fax1^ In Person REMARKS By Bryan Zuppiger Enclosures Esgil Corporation D GA D MB D EJ D PC 06/O7/05 trnsmtl dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 Carlsbad O5-2O57 June 17, 2005 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO 05-2057 JURISDICTION. Carlsbad PROJECT ADDRESS 1014 Tulip Way FLOOR AREA See Below STORIES 2 Dwelling addition 2101 ft2 Dwelling remodel 1735 ft3 HEIGHT 24'-6" at north elev. sheet A-3. DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION ESGIL CORPORATION 06/07/05 DATE INITIAL PLAN REVIEW PLAN REVIEWER. Bryan Zuppiger COMPLETED June 17, 2005 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), that adopts the following model codes 1997 UBC, 2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list for a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 05-2057 June 17, 2005 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, and (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 The person responsible for their preparation must sign all final sheets of plans (California Business and Professions Code) 3 Final plans, specifications and calculations shall be signed and sealed by the engineer or architect licensed by the State of California who is responsible for their preparation Specify expiration date of license (California Business and Professions Code) 4 Clearly show the existing versus the proposed on each sheet The foundation details are for a new house Please incorporate details that show how the new construction will connect to the existing construction 5 On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below UBC Section 106 3 2 • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with UBC Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS • EXPANSION/EPOXY ANCHORS YES PER APPROVING REPORT 6 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review UBC Section 106 3 5 Please complete parts 1, 2 & 3 of the attached form and resubmit Carlsbad 05-2O57 June 17, 2005 7 On the cover sheet of the plans, specify any items that will have a deferred submittal (trusses, etc ) Additionally, provide the following note on the plans. perUBCSec 10634.2 "Submittal documents for deferred submittal items shall be submitted to the architect or engineer of record, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official" • FIRE PROTECTION 8 When the valuation of a room addition exceeds $1,000, show permanently wired smoke detectors with battery backup in the new and existing construction. except that smoke detectors added at existing construction need only be battery powered UBC Section 310 9 1 2 a) Inside each bedroom b) Centrally located in corridor or area giving access to sleeping rooms c) On each story d) When sleeping rooms are upstairs, at the upper level in close proximity to the stair e) In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway NOTE Detectors shall sound an alarm audible in all sleeping areas of the unit. UBC Section 310 91 • EXITS, STAIRWAYS, AND RAILINGS 9 Provide stairway and landing details that are referenced to the floor plan UBC Sections 100333 a) Maximum rise is 7" and minimum run is 11" When the stairs serves less than 10 occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" minimum 10 Provide guardrail details that are referenced to the floor plan UBC Section 5091 a) Shall be installed at all unenclosed floor openings b) Shall be installed at balconies more than 30" above grade or floor below c) Shall have a height of 36" d) Shall have connection details adequate to resist the horizontal force prescribed in UBC Table 16-B e) Openings between railings shall be less than 4" Carlsbad O5-2O57 June 17, 20O5 11 Provide handrail details that are referenced to the floor plan UBC Section 1003336 a) Handrails are required on each side of stairways having four or more stairs Stairways less than 44" wide or stairways serving one dwelling unit may have one handrail (if not open on both sides) b) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous c) The handgrip portion of all handrails shall be not less than 1-1/4 inches nor more than 2 inches in cross-sectional dimension Handrails projecting from walls shall have at least 1-1/2 inches between the wall and the handrail d) Ends of handrails shall be returned or shall have rounded terminations or bends e) Openings between railings shall be less than 4" The triangular openings formed by the riser, tread and bottom element of a handrail at a stair shall be less than 6" • GENERAL RESIDENTIAL REQUIREMENTS 12 In addition to the information shown on the plans, specify in the following locations should be of safety glazing material in accordance with UBC Section 2406 4 (see exceptions) a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors See the Master bedroom • ROOFING 13 Specify on the plans the following information for the roof and balcony materials, per UBC Section 106 3 3 a) Manufacturer's name. b) Material weight c) Product name/number d) ICBO approval number, or equal 14 Show a 22"x30" access from the existing attic to the new attic 15 Balconies and decks exposed to the weather and sealed underneath shall be sloped a minimum of % inch per foot for drainage UBC Section 1402 3 16 Overflow roof drains shall terminate in an area where they will be readily visible and will not cause damage to the building If the roof drain terminates through a wall, the overflow dram shall terminate 12" minimum above the roof dram. Policy 84-35 Carlsbad 05-2O57 June 17, 2005 • GARAGE AND CARPORTS 17. Show a self-closing door, either 1-3/8" solid core or a listed 20 minute assembly, for openings between garage and dwelling Section 302 4 18. All elements supporting floor above garage, including walls/beams/columns supporting floor joists, must have one-hour fire-resistive protection on the garage side UBC Section 302 2 The structural plans are incomplete and vague. The following corrections are general in nature and based on the response more corrections may follow. For a complete review, submit construction drawings that reflect the scope of work. • FOUNDATION REQUIREMENTS 19 All new residential buildings, including additions, require a soils report An update letter is required if the report is more than 3 years old If a room addition is less than 1000 sq ft in area and only one story, then a soils report is not required 20 Provide a copy of the project soil report prepared by an Architect or Civil Engineer licensed by the State of California The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804 21 In Seismic Zone 4, each site shall be assigned a near-source factor Identify this value in the soils report and on the plans UBC Section 1629 4 2 22 Investigate the potential for seismically induced soil liquefaction and soil instability in Seismic Zones 3 and 4 This does not apply to detached, single- story dwellings UBC Section 1804.5 23 Note on the plan the soils classification, whether or not the soil is expansive and the allowable bearing value UBC Section 106 3.3. 24 If the soils engineer recommends that he/she review the foundation excavations note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that a) The building pad was prepared in accordance with the soils report, b) The utility trenches have been properly backfilled and compacted, and c) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report" Carlsbad 05-2057 June 17, 2005 25 Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report) 26 Specify size, I C B O number and manufacturer of power driven pins, expansion anchors or epoxy anchors Show edge and end distances and spacing UBC Section 10633 27 Show size, embedment and location of epoxy hold down anchors on foundation plan UBC Section 106 3 3 28 Note on plan that hold down anchors must be tied in place prior to foundation inspection UBC Section 108 5 2 29 Provide calculations for mam vertical and horizontal framing member loads on the footings UBC Section 106 3 3 Based on the response more corrections may follow • FRAMING 30 Provide truss details and truss calculations for this project Specify truss identification numbers on the plans Or submit a deferral 31 Show draglines and girder trusses on the plans 32 Note on the plan that the structural consultant shall provide a letter of review for the truss plans and calculations with their submittal 33 Check all headers for reactions from the Girder trusses 34 Include the FAU and platform on in the truss layout and calculations. Or submit a deferral 35 Detail truss layout for 30" x 30" attic access, if required for equipment in the attic and detail 30" x 30" clearance through truss webs, 22" x 30" may be used if the equipment size allows Or submit a deferral 36 If existing trusses are being modified please analyze and submit design Or submit a deferral 37 Specify all header sizes for openings at the roof framing and floor framing plan over 4' wide and the size is not identified on the plans UBC Section 2320 116 38 Provide calculations for lateral loads, shear panels, shear transfer and related Section UBC 106 3 3 Based on the response more corrections may follow 39 Please show in the calculations how the redundancy was determined, per UBC Section 1630 1 1 Based on the response more corrections may follow Carlsbad 05-2057 June 17, 2005 • MECHANICAL (UNIFORM MECHANICAL CODE) 40 Show the location, type and size (BTU's) of all heating and cooling appliances or systems Based on the response more corrections may follow 41 Show source of combustion air to furnace per Chapter 7 UMC Specify the location and sizes of both of the combustion air openings 42 Show minimum 30" deep unobstructed working space in front of furnace UMC Section 903 43 Note that passageway to the mechanical equipment in the attic shall be unobstructed and have continuous solid flooring not less than 24 inches wide, not more than 20 feet in length through the attic UMC Section 908 0 44 Show a permanent electrical receptacle outlet and lighting fixture controlled by a switch located at the entrance for furnaces located in an attic space UMC Section 908 0 45 Note on the plans that the FAU closet or alcove must be 12 inches wider than the furnace or furnaces being installed UMC Section 904 1 46 Provide installation details for furnaces located on the roof or the building exterior, UMC Section 910 0 47 The maximum length of a clothes dryer duct is 14 feet with (two) 90° elbows All terminations shall be 3' from any opening in a building UMC Section 504 2 2 • ELECTRICAL (NATIONAL ELECTRICAL CODE) 48 Show on the plan the amperage of the electrical service and sub-panels, the location of the service panel and the location of any sub-panels If service is over 200 amps, submit single line diagram, panel schedule and load calculations 49 In addition to the information shown on the plans, show on the plan the amperage and location of sub-panels Subpanels are not approved in garage firewalls, bathrooms, clothes or linen closets 50 Install a panel, grounding electrode, water and gas bond at each building's electric panel NEC Sections 230-70 & 250-24 (a) see exceptions 51 Show on the plans that receptacle outlet locations will comply with NEC Art 210-52(a) 52 For a single-family dwelling unit, show that at least one receptacle outlet accessible at grade level will be installed outdoors at the front and back of the dwelling NEC Art 210-52 (e) This receptacle must be GFCI protected Carlsbad O5-2O57 June 17, 2005 53 Show on the plans that countertop receptacle outlets in kitchens and dining areas of dwelling units a receptacle outlet shall be installed at each counter space wider than 12 inches Receptacles shall be installed so that no point along the wall line is more than 24 inches measured horizontally from a receptacle outlet in that space Island and peninsular countertops 12 inches by 24" long (or greater) shall have at least one receptacle Counter top spaces separated by range tops, refrigerators, or sinks shall be considered as separate counter top spaces NEC Art 210-52(c) 54 Per NEC Art 210-11 (c)3, note on the plans that bathroom circuiting shall be either a) A 20 ampere circuit dedicated to each bathroom, or b) At least one 20 ampere circuit supplying only bathroom receptacle outlets 55 Show on the plans a wall receptacle adjacent to each lavatory in the bathroom NEC Art 210-52(d) 56 Show on the plan that receptacle outlets in hallways 10 feet or more in length shall have at least one receptacle outlet NEC Art 210-52(h) 57 Show at least one wall switch-controlled lighting outlet to be installed in every habitable room, in bathrooms, hallways, stairways, attached garages, and detached garages with electric power, and at the exterior side of outdoor entrances or exits At interior stairways show 3-way switching for lighting outlets at each floor level where there are six or more steps NEC Art 210(a) 58 All bedroom branch circuits now require arc fault protection Note clearly on the plans that "Bedroom branch circuits will be arc fault circuit protected " NEC Art 210-12(b) 59 Show on the plan that all 125-volt, single-phase, 15- and 20- ampere receptacles installed in bathrooms, garages, basements, outdoors, at all kitchen counters and at wet bar sinks comply with the ground-fault circuit-interrupter protection specified in NEC Art 210-8 • PLUMBING (UNIFORM PLUMBING CODE) 60 Show water heater size (1st hour rating), type, and location on plans UPC Section 501 0 61 In the garage, provide an adequate barrier to protect water heater from vehicle damage An 18" platform for the water heater does not satisfy this requirement UPC, Section 5103 62 Show T and P valve on water heater and show route of discharge line to exterior UPC, Section 608 5 Carlsbad O5-2O57 June 17, 2O05 63 In Seismic Zones 3 and 4, show that water heater is adequately braced to resist seismic forces Provide two straps (one strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank) UPC, Section 510 5 • ENERGY CONSERVATION 64 Provide plans, calculations and worksheets to show compliance with current energy standards 65 The regulations require a properly completed and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design 66 Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and bathrooms (containing a tub or shower) 67 Note on the plans "The manufactured windows shall have a label attached certified by the National Fenestration Rating Council (NFRC) and showing compliance with the energy calculations " • MISCELLANEOUS 68 Please reconcile the drawing index with the sheets of the plans To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation Thank you Carlsbad O5-2057 June 17, 2005 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No 05-2057 Job Address or Legal Description 1014 Tulip Way Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet (over) Carlsbad O5-2O57 June 17, 2005 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: 1014 Tulip Way PLAN CHECK NUMBER: O5-2O57 OWNER'S NAME: _ I, as the owner, or agent of the owner (contractors may oat employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special inspectors) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at foe site listed above UBC Section 106.3 5 Signed ~~*^ r / I, as the engineer/architect of record, cerjffy that I have prepared the following special inspection program as required bylJBC Section 106 3 5 for the construction project located at the site listed above Signed L 1. List of work requiring special inspection: D Field Welding D B Structural Concrete Over 2500 PSI Prestressed Concrete Structural Masonry High Strength Bolting ^Expansion/Epoxy Anchors Sprayed-On Flreprooflng Designer Specified 2. Name(s) of indlvldual(s) or firm(s) responsible for the special Inspections listed above: A. B. C. 3. Duties of the special inspectors for the work listed above: A. B. C. Special Inspectors shall check In with the City and present their credentials for approval prior ^ beginning work on the job site 10 3EWd ma er-si g00z/«/T0 Carlsbad 05-2057 June 17, 2005 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: 1014 Tulip Way PLAN CHECK NUMBER: 05-2057 OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above Enginwr's/Archltact * S«l & Signature H«ra Signed 1. List of work requiring special inspection: D Field Welding G Structural Concrete Over 2500 PSI n Prestressed Concrete n Structural Masonry D High Strength Bolting G Expansion/Epoxy Anchors n Sprayed-On Fireproofing n Designer Specified 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above- A. B. C. 3. Duties of the special inspectors for the work listed above: A. B. C. Special inspectors shall check in with the City and present their credentials for approval pnor to beginning work on the job site City of Carlsbad Public Works — Engineering BUILDING PLANCHECK CHECKLIST DATE Uk/05 BUILDING ADDRESS fV{ ^ PROJECT DESCRIPTION ASSESSOR'S PARCEL NUMBER 7b(,> r)(L(~' L/ PLANCHECK NO CB <^7S>?O S ~7 9 { AJA,/ 1 ' / '(0 '{£. EST VALUE d^l.KO ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build D A Right-of-Way permit is required prior to construction of the following improvements DENIAL Please see the attached report of deficiencies marked with D Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review By By By Date Date Date FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT:, Date D Dedication Application D Dedication Checklist 0 Improvement Application D Improvement Checklist D Future Improvement Agreement D Grading Permit Application 0 Grading Submittal Checklist D Right-of-Way Permit Application rj Right-of-Way Permit Submittal Checklist and Information Sheet D Sewer Fee Information Sheet Name ENGINEERING DEPT CONTACT PERSON JOANNE JUCHNIEWICZ Address Phone City of Carlsbad 1635 Faraday Avenue, Carlsbad, CA 92008 (760) 602-2775 CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract Car|sbad CA 9200817314 • (760) 602-2720 • FAX (760) BUILDING PLANCHECK CHECKLIST J RD D 3' D SITE PLAN 1 Provide a fully dimensioned site plan drawn to scale Show A North Arrow B Existing & Proposed Structures C Existing Street Improvements D Property Lines E Easements Right-of-Way Width & Adjacent Streets Driveway widths Existing or proposed sewer lateral Existing or proposed water service D D 2 Show on site plan A Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building" B Existing & Proposed Slopes and Topography C Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways, per standards 3 Include on title sheet A Site address B Assessor's Parcel Number C Legal Description For commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc) previously approved EXISTING PERMIT NUMBER DESCRIPTION F BUILDING PLANCHECK CKLSTFORM doc BUILDING PLANCHECK CHECKLIST • ST RD3 D DISCRETIONARY APPROVAL COMPLIANCE 4a Project does not comply with the following Engineering Conditions of approval for Project No D 4b All conditions are in compliance Date DEDICATION REQUIREMENTS Q 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 15.000 . pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required as follows Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 Vz x 11" plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date D n D IMPROVEMENT REQUIREMENTS 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 75.000 . pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the F \BUILOINO PLANCHECK CKLST FORM.doc Rev 7/14/00 BUILDING PLANCHECK CHECKLIST «ST ,ND jRD D D checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $360 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows D D D D 6c Enclosed please find your Neighborhood Improvement Agreement Please return agreement signed and notarized to the Engineering Department Neighborhood Improvement Agreement completed by Date 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy n n n GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 15 16 010 of the Municipal Code 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial) This information must be included on the plans. 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) F \BUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST 3RD D 7d No Grading Permit required D n D 7e If grading is not required, write "No Grading" on plot plan MISCELLANEOUS PERMITS D 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm dram, sewer and water utilities Right-of-Way permit required for 9 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438-2722, extension 7153, for assistance Industrial Waste permit accepted by Date E/ D D 10 NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first [U EH 11 0 Required fees are attached [/No fees required WATER METER REVIEW D 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used • All single family dwelling units received "standard" 1" service with 5/8" service FeUIUWWPUUICHECKCia.STFORM.cloc c R«v 7/1*00 iST sRD D D 12b BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit • Maximum service and meter size is a 2" service with a 2" meter • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so, at the water meter station, the demand in gpm may be listed there Irrigation services are listed with a circled T, and potable water is typically a circled "W" The irrigation service should look like STA1+00 Install 2" service and 5 meter (estimated 100 gpm) 2 If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach) Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations, keep a set for your reference In general the calculations will include Hydraulic grade line Elevation at point of connection (POC) Pressure at POC in pounds per square inch (PSI) Worse case zone (largest, farthest away from valve Total Sprinkler heads listed (with gpm use per head) Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water F \BUILOING PLANCHECK CKLST FORM doc ., ST 2ND 3RD BUILDING PLANCHECK CHECKLIST service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future 12c Irrigation Use (where recycled water is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development For subdivisions, this should have been identified, and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this 13 Additional Comments; F \BUHDINGPLANCHECKCKLST FORM doc -7 Rev 7/14/00 Q] 1. Provide a fully dimensional site plan drawn to scale. Show:. North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Q 2. Provide legal description of property and assessor's parcel number. D an Policy 44 - Neighborhood Architectural Design Guidelines 1. Applicability: YES_^_NO 2. Project compiles YES NO a Zoning: 1. Setbacks: Front Interior Side: Street Side: Rear Top of slope: 2. Structure\separation: 3. Lot Coverage: Required. Required. Required. Required. Required. ire setbacks: Required. Required. Required. Required. Required _ Shown. Shown. Shown. Shown. Shown Required.7- Shown. Shown. Shown. Shown. Shown. Shown.A 4. Height Required.Shown. Spaces Required.Shown.5. Parking: (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown tf Additional Comments. /(//W TV S^tQB ) frON C0f\fF<?frM(N6 DJCTO ISSUE WND ENTERED APPROVAL INTO COMPUTER H^AOMI^«COUNTEF^BIdgPlnct*RtvCI*W 13. Planning Department City Of Carlsbad Faraday Road Carlsbad, CA RE: Side Yard Setbacks, Plan Check #05-2057 Dear Planning Director, Attached please find documentation showing that the above referenced permit for the property located at 1014 Tulip Way does conform to the side yard set backs. As per the requirements stated in Chapter 21.10.070, section 1, paragraph b. Please contact me directly if you need further documentation or clarification. I thank you in advance for your help with this matter Respectfully, Ray Baum Home Owner 1014 Tulip Way Carlsbad, Ca 760-931-6797 Hi PLANNINCMDERART^CENT APPROVAL RECOMMENDEDBK 06/27/2005 17-35 7604361213 BILL PERRY PAGE 01 ttftf p- \ o t DEPARTMENT APPROVAL DATE: / / Director DATE:/£/8/5 RECOMMENDED BYT/Lr I* r-*^ r swi»sn™s»*' GEOTECHNICAL INVESTIGATION BAUM RESIDENCE Tulip Way Carlsbad, California Job. No. 513 July 11,2005 I* • • i• •• •• • • ar 7107 Broadway, #316 Lemon Grove, CA 91945 Tel (619) 262-4832 Fax (619) 262-4878 July 11,2005 Mr RayBaum 1014 Tulip Way Carlsbad, California 92009 Project Job No 513 Baum Residence 1014 Tulip Way Carlsbad, California 92009 Subject Report of Geotechnical Investigation Dear Mr Baum In accordance with your request, we have completed a Report of Geotechnical Investigation for the proposed project We are presenting to you, herewith, our findings,; •. •. conclusions and recommendations for the construction of the proposed additign/£ernodel The findings of this study indicate that the site is suitable for the if the recommendations provided in our attached report are incorporated into construction of the project Baum Residence July 11,2005 Job No 513 Page 2 If you have any questions after reviewing the findings, conclusions and recommendations contained in the attached report, please do not hesitate to contact this office This opportunity to be of professional service is sincerely appreciated Respectfully submitted, tffar Dennis E Zimmerman, CE 26676, GE 928, Expires 3/31/06 Geotechmcal Engineer Attachments Distribution (3) Addressee DEZmb • •• • i • • ••••• ••• • • <J-Jen friar GEOTECHNICAL INVESTIGATION BAUM RESIDENCE 1014 TULIP WAY CARLSBAD, CALIFORNIA Prepared For: Mr. Ray Baum 1014 Tulip Way Carlsbad, California JOB NO. 513 July 11,2005 Table of Contents Page Introduction and Project Description 1 Project Scope 2 Findings 3 Site Descnption 3 Subsurface Conditions 3 Formation 3 Fill 3 Groundwater 3 Geologic Hazards 4 Faults and Seismic Hazards 4 Seismicity of Major Faults 6 Liquefaction 6 Landslides and Slope Stability 7 Conclusions and Recommendations 7 Site Preparation 7 Existing Soil 7 Soil Suitability 8 Expansive Soil 8 Imported Fill 8 Surface Drainage 8 Earthwork 9 Foundation Recommendations 9 Footings 9 Lateral Resistance •,..; JO Footing Observations m 10 Concrete Slabs-On-Grade i\!ll Transition Areas • » • • 12 Footing Setbacks I .*. *****J2 Active Pressure ^ t't * * * \ 13 Backfill *.: .* %,M3 Seismic Site Categorization • 13 Field Explorations „ ,.J4 Laboratory Testing 15 Limitations 15 • ••• • <Jjen 11 far Page Attachments 18 Plate Number 1 Subsurface Exploration Legend 19 Plate Number 2 Subsurface Exploration Log T-l 20 Plate Number 3 Subsurface Exploration Log T-2 21 Plate Number 4 Laboratory Test Results 22 Plate Number 5 Removal Depths, Table I 23 Appendix I 24 Standard Specifications for Construction of Controlled Fills 25 Appendix II 29 References 30 Baum Residence Job No 513 July 11,2005 Page 2 Project Scope This investigation consisted of a surface reconnaissance coupled with a subsurface exploration Representative soil samples were obtained from the site and returned to our laboratory for observation and testing The results of the field and laboratory data collected are presented in this report Specifically, the intent of this investigation was to a) Address geologic hazards, including faults and seismicity b) Explore the subsurface conditions to the depths that could be influenced by the proposed construction, c) Evaluate, by laboratory tests, the pertinent static physical properties of the various soil and rock stratigraphic units which could influence the development of this project, including bearing capacities, lateral soil pressures, and settlement potential, and d) Present recommendations for foundation design and floor slab support ;..,?- 3 •> -> This report has been prepared for Mr Ray Baum to be used in the evaluaiym and 4e§igri 33 t > » 1 of the proposed project This report has not been prepared for use by other pames, and m?y hbt> "*»u •« • contain sufficient information for purposes of other parties or other uses The information Hbfhis report represents professional opinions that have been developed using that degree of care and f< 33m, skill ordinarily exercised, under similar circumstances, by reputable geotechmcal consultants practicing in this or similar localities No other warranty, express or implied, is made as to the professional advice included in this report ar Baum Residence Job No 513 July 11, 2005 Page 4 significant "cut" or any "below-grade" structures Therefore, consideration must be given to appropriate surface and subsurface drainage systems, such as underdrams and concrete surface swales Geologic Hazards Faults and Seismic Hazards: The numerous fault zones in southern California include active, potentially active, and inactive faults Active faults are those which display evidence of movement within Holocene time (from the present to approximately 11 thousand years) Faults that have ruptured geologic units of Pleistocene age (11 thousand to 2 million years) but not Holocene age materials are considered potentially active Inactive faults are those which exhibit movement that is older than 2 million years According to available published information, there are no known active or potentially active faults which intercept the project site The site is not located within an Alquist-Pnolo Special Studies Zone Therefore, the potential for ground rupture at this site is consideredJRAv** There are, however, several active faults located in close proximity, andthtAtment * * associated with them could cause significant ground motion at the site Nearby^ faults mclude*ttie Rose Canyon fault zone, which lies approximately 5 miles offshore to the westjtRet^oronafio^* Bank fault zone, located approximately 22 miles to the southwest (offshore) and the Elsm6W»«* • • • fault zone, which occurs 24 miles to the northeast Evidence suggesting movement along tlie Rose Canyon fault zone during the Holocene has been presented by Moore and Kennedy (1975) The State of California has zoned portions of the Rose Canyon fault zone as active under the •••••• •**•*• * ..... ar Baum Residence Job No 513 July 11,2005 Page 5 Alquist-Pnolo Senate Bill This has come about as a result of faulted paleosols in Rose Canyon that are considered to be unquestionably of Holocene age (T Rockwell, 1989) The Coronado Bank fault zone is a complex series of left-and-nght stepping enechelon faults Marine geophysical studies performed by Kennedy and Welday (1980) and others have provided evidence that Holocene sediments have been offset by several faults associated with the Coronado Bank fault zone Therefore, this fault system should also be considered active The Elsinore fault zone, which occurs approximately 24 miles to the northeast, is considered active with an estimated average recurrence interval of 60 years The table below presents the maximum credible and maximum probable earthquake magnitudes and estimated peak ground accelerations anticipated at the site These accelerations are based on the assumption that the maximum probable earthquake occurs on specific faults at the closest point on that particular fault to the site The maximum credible earthquake is defined as the maximum earthquake that appears to be reasonably capable of occurring under the conditions of the presently known geologic. . framework The probability of such an earthquake occurring during the lifetime of this • • •considered low The maximum probable earthquake is considered an event hajving a return., period of 100 years .•:*•. •• • • •• • .. Baum Residence July 11,2005 Job No 513 Page 6 Seismicity of Major Faults Fault Coronado Banks Elsmore Rose Canyon San Andreas San Jacmto Distance (Miles) 22 24 5 74 48 Maximum Credible Magnitude (Richter) 7 6L(2) 75L(3) 70M2) 83U3) 78U3) Maximum Probable Magnitude (Richter) 67 66 59 80 70 Estimated Bedrock Acceleration (g) 016 015 037 008 007 L= Local Magnitude (1) Seed and Idnss, 1982 (2) Slemmons, 1979 (3) Greensfelder, C D M G Map Sheet 23,1994 The preceding table suggests that the Rose Canyon fault zone would have the predominant influence on the site The postulated design earthquake and ground acceleration is presented in the table below Design Earthquake Fault Zone Source Maximum Probable Magnitude (Richter) * Sustained • *Peak Ground Acceleration Acceleratioti*"; (g) (g) • ••• Rose Canyon 59 037 024 Sustained Acceleration considered to be 65% of peak ground acceleration • • •• • •• • • • • i• • • Liquefaction: The property is underlain by very dense formational soil In addition, groundwater was not observed Based on the consistency of the underlying matenals and the Baum Residence Job No 513 July 11, 2005 Page? anticipated recompaction of overburden soils and the construction of drainage systems, the potential for generalized liquefaction in the event of a strong to moderate earthquake on nearby faults is considered very low Landslides and Slope Stability: No evidence suggesting the presence of deep seated landslides was observed on the project site or immediate site vicinity No jointing, fractures, remolded clay seams or other adverse geologic structures were noted within the exploratory trench excavations Conclusions and Recommendations Site Preparation: Existing Soil: Fill soils were encountered beneath the existing ground surface in trenches T-l and T-2 The fill soils are not uniformly consolidated and therefore are not considered suitable for foundation, driveway, hardscape or floor slab support To provide more uniform support for the proposed footings and slabs-on-grade, wt recommend that any existing fill, or otherwise unsuitable soil material beneatltthi ifcw footings and slabs be removed to very dense formational soil The new footings shall be'suiJported oft** undisturbed very dense soil The slabs-on-grade shall be entirely supported oa«»«ii«imum of •••••• •••• one foot of compacted soil or entirely on undisturbed very dense soil * * * * Based on the results of our analysis, it appears that the depth of removal will range from 1 to l'/2 feet Table I (Plate No 5) of this report presents anticipated removal depths in the area ff/ar Baum Residence Job No 513 July 11,2005 PageS of our subsurface explorations If groundwater is encountered during the removal and recompaction of the soil, or if difficulty is experienced in achieving the minimum of 95 percent relative compaction (ASTM D1557-00), then this office shall be consulted for further recommendations Soil Suitability: The on-site soil materials minus any rock greater than 2 inches, debris, expansive soils and organic matter may be used as typical fills as described in the attached Standard Specifications for Construction of Controlled Fills (Appendix I) Expansive Soil: Detrimentally expansive soils (Expansion Index of 31 or greater) were observed within our exploratory excavations Foundation recommendations herein consider these expansive soils Imported Fill: Imported fill, if required at this site, shall be approved by our office prior to importing Imported fill shall consist of very low to non-expansive soil (Expansion Index of 30 or less) and less than 25 percent shall pass the No 200 U S standard sieve Surface Drainage: Surface drainage shall be directed away from structures The ponding of water or saturation of soils should not be allowed adjacent to any of the foundations Sur^ce. gradients of one percent for hardscaped areas and two percent for landscaped ereasShould be • • • • • •maintained within 10 feet of any structures, wherever possible We recommenq Jjjat plantej$ ge provided with drams and low flow irrigation systems Gutters, roof drains and* ether drainage" devices shall discharge water away from the structure into surface drains or subsurface storm * * drains Area drains shall be provided, as necessary • •••• • •• • • ar Baum Residence July 11,2005 Job No 513 Page 9 Earthwork: All structural fill and utility trench backfill shall be compacted to no less than 95 percent of its maximum dry density (ASTM Dl 557-00) The moisture content of very low to non-expansive fill should be within two percent of optimum All deleterious materials and oversized debris (greater than 2 inches in maximum dimension) encountered must be removed and legally disposed of at a licensed disposal site The maximum dry density and optimum moisture content of each soil type shall be determined in accordance with ASTM Test Method D1557-00 Foundation Recommendations Footings: The dwelling shall be supported on continuous or pad spread footings To provide more uniform support we recommend that the foundations be entirely supported on undisturbed very dense soil Footings shall be designed with the minimum dimensions and allowable dead plus live load soil bearing values given in the following table Footings Established on Undisturbed Very Dense Soil Footing Type Continuous Pad Minimum Depth (inches) 18 24 Minimum Width (inches) 15 24 Allowable Soil Bearing! Value (p s.*f.) ] 1500 :.. 2000 ."., The minimum depth given shall be below lowest adjacent finish grade Footings s*hall be founded at least 12 inches into very dense soil rr/ar Baum Residence July 11,2005 Job No 513 Page 10 All continuous footings shall contain adequate reinforcing bars so as to provide structural continuity and to permit spanning of local irregularities The final foundation dimensions and reinforcing steel shall be designed by a Civil Engineer The soil load bearing values presented above may be increased by one-third for short term loads, including wind or seismic The soil bearing values of any proposed import soil should be determined after its selection, but prior to importing to the site Settlements under building loads are expected to be within tolerable limits for the proposed dwelling Lateral Resistance: Resistance to lateral loads may be provided by friction at the base of the footings and floor slabs and by the passive resistance of the supporting soils Allowable values of fnctional and passive resistance are presented in the table below The frictional and passive resistance of the materials may be combined without reduction in determining the total lateral resistance Lateral Resistance Values Soil Type Compacted Fill Undisturbed Soil Coefficient of Friction 035 045 Allowable Passive Pressure (psf/ft ofdeptjf)*: 350 I .'• 450 ••:• • • Footing Observations: Prior to the placement of reinforcing steel, all foundation V V V excavations shall be inspected by the Soil Engineer Footing excavations shall be cleaned of any • •••• • **L)en if far Baum Residence Job No 513 July 11,2005 Page 11 loosened soil and debris before placing rebar Footing excavations should be observed and probed for soft areas Any soft or disturbed soils shall be overexcavated prior to placement of rebar Excavations shall not be backfilled with soil in order to make bottom of footings smooth and level Bottom of footings should be left exposed on very dense soil Concrete Slabs-On-Grade: If the soils are prepared as recommended in this report, concrete slabs-on-grade may be supported entirely on very low to non-expansive compacted fill or entirely on undisturbed very dense soil No cut/fill transitions should be allowed to occur beneath the slabs-on-grade To provide protection against vapor or water transmission through the building and floor slabs, we recommend that the slabs-on-grade be underlain by a 4-mch layer of clean sand An impermeable membrane, as described below, should be placed at the midheight of the sand layer In areas where vinyl or other moisture-sensitive floor coverings are planned or where moisture may be determined to be detrimental to the structure's contents, we recommend that a 15-mil-thick impermeable plastic membrane (Stego Wrap or approved equal) be installed to provide additional protection against water vapor transmission through the slab The vapOt. . ! . barrier should be installed in accordance with the manufacturer's instructions.,^YejpcomtneW*• • •• • • • that the membrane edges be sealed Sand screeds should be used in lieu of scr$ed*pms soaVnot to puncture the membrane All plumbing, electrical and any other penetrationS^ioilld be'Ughtly sealed with Stego red tape or approved equal A low-slump concrete (4 inch maximum slump) should be used to minimize curlmg«)f • the slabs The concrete slab should be allowed to cure properly before placing vinyl or other .****• ar Baum Residence Job No 513 July 11, 2005 Page 12 moisture-sensitive floor covering The flooring contractor should verify the moisture vapor transmission through the slab just prior to installing floor coverings Slab reinforcing and thickness shall be designed in accordance with the anticipated use of and loadings on the slab and as recommended by the Civil Engineer As a minimum, we recommend #4 bar at 18 inches on center, each way Weakened plane joint spacing and construction joint spacing and placement shall be provided by the Civil Engineer As a minimum, we recommend a maximum spacing of 12 feet each way and a minimum depth of one-fourth of the slab thickness Every third bar should be discontinued at each weakened plane joint Transition Areas: The structure should not be allowed to straddle a cut-fill transition line The tendency of cut and fill soils to compress differently can frequently result in differential settlement, cracking to portions of the structure and in severe cases, structural damage To reduce the potential for damage due to differential settlement m transition areas, we recommend that cut areas be over- excavated to a depth of at least 1 foot below the bottom of the slab subgrade and replaced with very low to non-expansive soil material compacted to at Ieasfc95 • percent of its maximum dry density (ASTM D1557-00) Footing Setbacks. Where footings for structures are proposed adjacent to Jhe*tpp o• • we recommend that a minimum horizontal setback from the outer edge of the fs&tnig to tne» •••• • • adjacent slope face be provided A minimum setback of eight feet from the slope'face shafljj^ maintained The building setback distance from the top of slopes may be modified by using deepened footings Footing setback is measured from competent soil and should neglect any ^ :**•!" !!.!!.**• • * I I • ••• • •• •• • •• ••••• ar Baum Residence Job No 513 July 11,2005 Page 13 loose soils that may occur on the face of a slope or at the top of a slope Active Pressure: The active soil pressure for the design of unrestrained earth retaining structures with level backfill may be assumed to be equivalent to the pressure of a fluid weighing 35 pounds per cubic foot For restrained earth retaining structures with level backfill, the active soil pressure may be assumed to be equivalent to the pressure of a fluid weighing 35 pounds per cubic foot plus a uniform pressure of 7H pounds per square foot, where H equals the height of the backfill above the top of the footings These pressures do not consider any surcharge These values also assume a drained backfill condition We recommend that the Geotechnical Consultant observe all retaining wall subdrams to verify proper construction Backfill. All wall backfill soils should be compacted to at least 95 percent relative compaction Expansive or clayey soils should not be used for backfill material The wall should not be backfilled until the masonry or concrete wall has reached an adequate strength but not less than 21 calendar days Cantilever retaining walls should be supported by temporary shoring prior to placement of wall backfill The top of walls designed as restraining walls shall be supported by the floor diaphragm prior to the placement of wall backfill I... I. Seismic Site Categorization: The following seismic site categonzation.pasaaieters^m»ybe ....* used for foundation design These design parameters are based on the informatroit provided «" .... •• . Chapter 16, Section 1636 of the 2001 California Building Code, California Code of R..... ......Title 24, Part 2, Volume 2 *•••••. • •• • • ........... "..... fr/ar Baum Residence Job No 513 July 11,2005 Page 14 Soil Profile Type - Sc (Table 16-J) Near Source Factor, Na - 10 (Table 16-S) Near Source Factor, Nv = 10 (Table 16-T) Seismic Source Type = B (Table 16-U) Field Explorations Subsurface conditions beneath the proposed residence were explored by excavating two trenches on June 25, 2005 The trenches extended to depths ranging from 21A to 7 feet below existing grade Caving of the trench walls were not observed The exploratory excavation locations are described as follows Trench T-l was excavated near the northwest corner of the house, while trench T-2 was excavated on the south side of the house near the front entry The surface reconnaissance and subsurface exploration were conducted by our soil engineering personnel The soils are described m accordance with the Unified Soil Classification System as illustrated on the attached simplified chart (Plate No 1) In addition, a verbal textural description, the wet color, the apparent moisture and the density of consistency are presented The density of granular material is given as either very loose, loose, medium dense, dense or very dense The consistency of silts or clays is given as either very soft, soft, medium stiff, stiff, very stiff or hard The sampling and logging of our exploratory excavations were performed using standard geotechmcal methods The logs are presented on Plate No 2 and Plate No 3 Samples of typical and representative soils were obtained and returned to our laboratory for observation and testing ar Soil Description SUBSURFACE EXPLORATION LEGEND UNIFIED SOIL CLASSIFICATION CHART Group Symbol Typical Names A COARSEGRAINED More than half of material is larger than No 200 sieve size Gravels More than half of coarse fraction is larger than No 4 sieve size but smaller than 3" CLEAN GRAVELS GRAVEL W/FINES Sands More than half of coarse fraction is smaller than No 4 sieve size CLEAN SANDS SANDS W/FINES B FINEGRAINED More than half of material is smaller than No 200 sieve size Silts & Clays Liquid limit less than 50 Silts & Clays Liquid limit greater than SO HIGHLY ORGANIC SOILS GW GP GM GC sw SP SM SC ML CL OL MH CH OH PT Well graded gravels, gravel sand mixtures, little or no fines Poorly graded gravels, gravel sand mixtures, little or no fines Silty gravels, poorly graded gravel-sand-silt mixtures Clayey gravels, poorly graded gravel-sand, clay mixtures Well graded sand, gravelly sands, little or no fines Poorly graded sands, gravelly sands, little or no fines Silty sands, poorly graded sand and silt mixtures Clayey sands, poorly graded sand and clay mixtures Inorganic silts and very fine sans, rock flour, sandy silt or clayey-silt-sand mixtures with slight plasticity Inorganic clays of low to medium plasticity, gsawfiy clays, sandy clays, silty clays, lean clays * Organic silty and organic silty <3ay»o5low plasticity 'I • •• • •• • • •• • • Inorganic silts, micaceous or diatomapeous fifie^andy or silty soils, elastic silts ... . < Inorganic clays of high plasticity.fet . Organic clays of medium to high plasticity Peat and other highly organic soils Baum Residence Page 19 Plate No 1 SUBSURFACE EXPLORATION LOG [ - i- - 2- 3- - 4- 5- 6- 7- 8- 9- - 10- 11- _ 12- 13- 14- 15-SAMPLE TYPEB SOILCLASSIFICATIONSM CL SP JOB NUMBER 513 TRENCH NO T-l LOCATION NE Corner SAMPLING METHOD Bobcat DESCRIPTION ARTIFICIAL FILL TAN, SILTY FINE SAND REDDISH DARK BROWN WEATHERED CLAYSTONE FORMATION TAN, FINE TO MEDIUM GRAINED SAND BOTTOM OF TRENCH = T SAMPLE LEGEND B = BULK SAMPLE BAUM RESIDENCE APPARENTMOISTUREDAMP DAMP DAMP APPARENTCONSISTENCYMEDIUM DENSE HARD VERY DENSE 1 UJ f\ S^x .. • 1 • DATE LOGGED 6/25/05 MOISTURECONTENT (%).... • •RELATIVECOMPACTION %...:. . . i • ; » • f - -1 - -2 -3 - -4 -5 -6 -7 -8 -9 - -10 -".:. !• -12. • • 4 4 -14* • -15 LOGGED BY DEZ Baum Residence Page 20 Plate No 2 SUBSURFACE EXPLORATION LOG UJu_ 1- 2- - 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15-SAMPLE TYPESOILCLASSIFICATIONSM SM JOB NUMBER 513 TRENCH NO T-2 LOCATION At Entry SAMPLING METHOD Hand DESCRIPTION ARTIFICIAL FILL - SILTY, FINE GRAINED SAND FORMATION - TAN FINE TO MEDIUM GRAINED SAND BOTTOM OF TRENCH = 2>A' BAUM RESIDENCE APPARENTMOISTUREDAMP DAMP APPARENTCONSISTENCYLOOSE VERY DENSE 1UJ Q O :, . DATE LOGGED 6/25/05 MOISTURECONTENT (%)• # • • ^ 9 I.".RELATIVECOMPACTION %»• • • • > • • • • UJU- -1 -2 - -3 -4 -5 -6 -7 -8 -9 -10 -H! • • -12 * • • -1ST I -14*' -15 LOGGED BY DEZ Baum Residence Page 21 Plate No 3 LABORATORY TEST RESULTS Mechanical Sieve Analysis Sample Location T-l (g>, 5' Sieve Size Percent Passing #4 100 #16 100 #30 100 #50 88 #100 55 #200 35 4 Baum Residence Page 22 Plate No 4 REMOVAL DEPTHS Table I Depth of Soil Removal Below Test Pit Existing Grade Number (Feet) T-l T-2 It should be recognized that variations in soil conditions may occur between exploratory excavations that will require additional or deeper removal Rock may be encountered requiring blasting, a rock breaker, expansive grout or other approved procedures for removal •• • • ........ • •••••••• * • Baum Residence Page 23 Plate No 5 Baum Residence July 11,2005 Job No 513 Page 24 APPENDIX I • • Baum Residence July 11,2005 Job No 513 Page 25 SPECIFICATIONS FOR CONSTRUCTION OF CONTROLLED FILLS General Description: The construction of controlled fills shall consist of adequate geotechmcal investigations, and clearing, removal of existing structures and foundations, preparation of land to be filled, excavation of earth and rock from cut area, compaction and control of the fill, and all other work necessary to complete the grading of the filled area to conform with the lines, grades, and slopes as shown on the accepted plans Cleanng and Preparation of Areas to be Filled: (a) (b) (c) (d) (e) (f) All fill control projects shall have an investigation or a visual examination, depending upon the nature of the job, performed by a qualified soil engineer prior to grading All timber, trees, brush, vegetation, and other rubbish shall be removed, piled and burned, or otherwise disposed of to leave the prepared area with a finished appearance free from unsightly debris Any soft, swampy or otherwise unsuitable areas, shall be corrected by drainage or removal of compressible material, or both, to the depths indicated on the plans or as directed by the soil engineer The natural ground which is determined to be satisfactory for the support of the filled ground shall then be plowed or scanfied to a depth of at least six inches (6") or deeper as specified by the soil engineer, and until the surface is free from ruts, hummocks, or other uneven features which would tend to prevent uniform compaction by the equipment to be used • No fill shall be placed until the prepared native ground has beeivapjpreved by the soil engineer • • • • •• •• Where fills are made on the hillsides with slopes greater than 5 .., • (horizontal) to 1 (vertical), horizontal benches shall be cut into fim •* undisturbed natural ground to provide lateral and vertical stability *Tlfe initial bench at the toe of the fill shall be at least 10 feet in width'onYirm undisturbed natural ground at the elevation of the toe stake The soil engineer shall determine the width and frequency of all succeeding benches which will vary with the soil conditions and the steepness of slope Baum Residence Job No 513 July 11,2005 Page 26 (g) After the natural ground has been prepared, it shall be brought to the proper moisture content and compacted to not less than 90% of maximum density, A S T M D1557-00 (h) Expansive soils may require special compaction specifications as directed in the report of geotechnical investigation by the soil engineer (i) The cut portions of building pads may require excavation and recompac- tion for density compatibility with the fill as directed by the soil engineer Materials' The fill soils shall consist of select materials graded so that at least 40 percent of the material passes the No 4 sieve The material may be obtained from the excavation, a borrow pit, or by mixing soils from one or more sources The matenal used shall be free from vegetable matter, and other deletenous substances, and shall not contain rocks or lumps greater than 6 inches in diameter If excessive vegetation, rocks, or soils with unacceptable physical characteristics are encountered, these matenals shall be disposed of in waste areas designated on the plans or as directed by the soil engineer If soils are encountered during the grading operation which were not reported in the report of geotechnical investigation, further testing will be required to ascertain their engineering properties Any special treatment recommended in the preliminary or subsequent soil reports not covered herein shall become an addendum to these specifications No matenal of perishable, spongy, or otherwise unstable nature shall be used in the fills Placing, Spreading and Compacting Fill Material' •(a) The selected fill matenal shall be placed in layers which shall not exceed • six inches (6") when compacted Each layer shall be spread evaaty «ad • shall be thoroughly blade-mixed during the spreading to insure nnifbnmty of material and moisture in each layer I •"• *• v v v * (b) When the moisture content of the fill matenal is below that specified* by the soil engineer, water shall be added until the moisture content t£ hear optimum as determined by the soil engineer to assure thorough b'ondmg during the compacting process • ... < . •••• • I• • • Baum Residence Job No 513 July 11,2005 Page 27 (c) When the moisture content of the fill matenal is above that specified by the soil engineer, the fill material shall be aerated by bladmg and scarifying, or other satisfactory methods until the moisture content is near optimum as determined by the soil engineer (d) After each layer has been placed, mixed and spread evenly, it shall be thoroughly compacted to not less than the specified maximum density in accordance with A S T M Dl 557-00 Compaction shall be by means of tamping or sheepsfoot rollers, multiple-wheel pneumatic-tired rollers, or other types of rollers Rollers shall be of such design that they will be able to compact over its entire area and the roller shall make sufficient passes to obtain the desired density The entire area to be filled shall be compacted to the specified density (e) Fill slopes shall be compacted by means of sheepsfoot rollers or other suitable equipment Compacting operations shall be continued until the slopes are stable and until there is no appreciable amount of loose soil on the slopes Compacting of the slopes shall be accomplished by backrolling the slopes in increments of 3 to 5 feet in elevation gam or by other methods producing satisfactory results (f) Field density tests shall be made by the soil engineer for approximately each foot in elevation gain after compaction, but not to exceed two feet in vertical height between tests The location of the tests in plan shall be spaced to give the best possible coverage and shall be taken no farther than 100 feet apart Tests shall be taken on corner and terrace lots for each two feet in elevation again The soil engineer may take additional tests as considered necessary to check on the uniformity of compaction ••••!• Where sheepsfoot rollers are used, the tests shall be taken in the .. . compacted material below the disturbed surface No additionaUajaare of • *••* fill shall be spread until the field density tests indicate that the specified * density has been obtained I •'• (g) The fill operation shall be continued in six inch (6") compacted layers, as *•• • •*!... specified above, until the fill has been brought to the finished slopes dhd ^*. * .. grades as shown on the accepted plans *.•••* •••••• Baum Residence Job No 513 July 11,2005 Page 28 Supervision: Supervision by the soil engineer shall be made during the filling and compacting operations so that he/she can certify that the fill was made in accordance with accepted specifications The specifications and soil testing of subgrade, subbase, and base materials for roads, or other public property shall be done in accordance with specifications of the governing agency Seasonal Limits* No fill matenal shall be placed, spread, or rolled during unfavorable weather conditions When the work is interrupted by heavy ram, grading shall not be resumed until field tests by the soil engineer indicate that the moisture content and density of the fill are as previously specified In the event that, in the opinion of the engineer, soils unsatisfactory as foundation matenal are encountered, they shall not be incorporated m the grading, and disposition will be made at the engineer's discretion •••• . . •t . • ...•• • •• • . ••••.......... ;••••; Baum Residence July 11,2005 Job No 513 Page 29 APPENDIX II •• •• Baum Residence Job No 513 July 11,2005 Page 30 REFERENCES California Department of Conservation, Division of Mines and Geology, 1998, Maps of Known Active Fault Near Source Zones in California and Adjacent Portions of Nevada, International Conference of Building Officials Greensfelder, R W, 1974, Maximum Credible Rock Acceleration from Earthquakes in California, Division of Mines and Geology, Map Sheet 23 Kennedy, M P , 1975, Geology of The San Diego Metropolitan Area, California, California Division of Mines and Geology, Bulletin 200 Kennedy, M P and Welday, E E, 1980, Regency and Character of Faulting Offshore Metropolitan San Diego, San Diego, California Division of Mines and Geology, Map Sheet 40 Moore, G W , and Kennedy, M P , 1975, Quaternary Faults at San Diego Bay California, U S Geological Survey, Journal Research, Vol 3, pp 589-595 Rockwell, T K 1989, Holocene Activity of the Rose Canyon Fault in San Diego Based on Trenching Studies Evidence ofM6+ Surface Rupturing Earthquakes, in The Seismic Risk in the San Diego Region Special Focus on the Rose Canyon Fault System Seed, H B and Idnss, I M , 1982, Ground Motions and Soil Liquefaction During Earthquakes, EERI Monograph Series Slemmons, D B , 1979, Evaluation of Geomorphic Features of Active Faults for Engineering Design and Siting Studies, Association of Engineering Geologists Short Course !...!• Tan, S And Kennedy, M P, 1996, Geologic Maps for the Northwestern Part ofAau J)ieg& *••" ;••:*: County, California California Division of Mines and Geology, Open-File keport 96-02 *.. I. I Terzaghi, Karl and Peck, Ralph B , 1948, Soil Mechanics in Engineering Practic&JlohnWilsy, ^ and Sons, Inc *.5 .* *••*•* .•• Weber, Harold F Jr, 1982, Recent Slope Failures, Ancient Landslides, The North-Central Coastal Area, San Diego County, California California Divisioiuof •• Mines and Geology, Report 82-12 "••" • City of Carlsbad Building Department CERTIFICATE OF COMPLIANCE PAYMENT OF SCHOOL FEES OR OTHER MITIGATION This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit The City will not issue any building permit without a completed school fee form Project Name Building Permit Plan Check Number Project Address APN Project Applicant (Owner Name) Project Description Building Type Residential TuJUp -QO D a Number of New Dwelling Units Square Feet of Living Area in New Dwelling Second Dwelling Unit Square Feet of Living Area in SOU Residential Additions Net Square Feet New Area <Q\0\ Commercial/Industrial Square Feet Floor Area City Certification of .A Applicant Information c/\OUUi\A,Date IQ\ THE CITY OF CARLSBAD Carlsbad Unified School District 6225 El Cammo Real Carlsbad CA 92009 (331-5000) Encmitas Union School District 101 South Rancho Santa Fe Rd Encmitas, CA 92024 (944-4300 ext 166) San Marcos Unified School District 215MataWay San Marcos, CA 92069 (290-2649) Contact Nancy Dolce (By Appt Only) San Dieguito Union High School District 710 Encmitas Blvd Encmitas, CA 92024 (753-6491) Certification of Applicant/Owners The person executing this declaration ("Owner") certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or that the person executing this declaration is authorized to sign on behalf of the Owner Signature Date Revised 4/20/00 1635 Faraday Avenue • Building Counter Carlsbad, CA 92008-7314 • (760) 602-2700 • (760) 602-2719 • FAX (760) 6O2-8558 SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school distnct(s))************************************************** THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED SCHOOL DISTRICT The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District The City may issue building permits for this project SIGNATURE OF AUTHORIZED SCHOOL DISTRICT OFFICIAL TITLE GAYLEN FREEMAN DEPUTY SUPERINTENDENT NAME OF SCHOOL DISTRICT DATE CARLSBAD^ CA920W PHONE NUMBER Revised 4/20/00 j [ CARLSBAD UNIFIED SCHOOL DISTRICT ( j JEFFERSON ELEMENTARV | \ AVIARA OAKS ELEMENTARY [ | CARLSBAD HIGH SCHOOL | J MAGNOLIA ELEMENTARY \ [ AVIARA OAKS MIDDLE SCHOOL [ | CARLSBAD VILLAGE ACADEMY [ ] CALAVERA HILLS SCHOOL \ \FHCIFICRIM | [ VALLEY MIDDLE SCHOOL j J KELL FV SCHOOL [ | CALAVERA HILLS MIDDLE SCHOOL I \BUeNAVISnsCHClOL [ ~~| HOPE SCHOOL [ | OTHER RECEIVED FROM (It Applicable) PARENT OR 0ajuur DATE Receipt No 19076 AMOUNT RECEIVED BY CASH __.CHECK TOTAL Sep Ju uo 7107 Broadway, <Q16 Lemon Grove, CA 91945 September 29,2005 Mr Ray Bum 1014 Tulip Way Carlsbad, California 92009 Project Job No 513 Baum Residence 1014 Tulip Way Carlsbad, California 92009 Subject. Review of Construction Documents Dear Mr Baum In accordance with your request, we have completed a review of the Foundation Plan and Details Sheet for the proposed project. We are presenting to you, herewith, our findings We have reviewed the Foundation Plan (Sheet S-t) and the Details (Sheet S-4) We have determined that the recommendations in our Geotechmcal Investigation Report are properly incorporated into the construction documents of August, 2005. and prepared by S"*vn Engineering with certain exceptions noted below C6 Baum Residence September 29,2005 Job No 513 Page 2 1 The slab note on the Foundation Plan (shown in 2 places) shall be changed from #3 to #4 and 6 mil visqueen to IS mil Stego Wrap, or equal (no known equal) 2 The tame shall apply for the slab note in details A/S-1, B/S-1, l/S-4 and 2/S-4 If you bave any questions after reviewing the findings contained in the attached plan review report, please do not hesitate to contact this office Respectfully sobnutted, Dennis E. Znnmennag.lCE 26676, GE 928, Expires 3/31/06 Geotcchntcal Engineer Attachments Distribution (3) Addressee DEZmb B>tso D O COCO < I- LUo CQ — vn c° V T i A' A4 "2 Q) 0 ^"Q)"5, c £ o ^ • v eJ %^2. 04-02-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No PCR07040 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title 1014 TULIP WYCBAD PCR 2144101200 Lot# $0 00 Construction Type CB05-2057 BAUM RESIDENCE REVISE STRUCTURAL PAGES &CALCS 0 NEW Status Applied Entered By Plan Approved Issued Inspect Area Applicant BAUM RAYMOND C 1014 TULIP WAY CARLSBAD CA 92011 Owner BAUM RAYMOND C 1014 TULIP WAY CARLSBAD CA 92011 ISSUED 02/23/2007 MDP 04/02/2007 04/02/2007 Plan Check Revision Fee Additional Fees $900 00 $000 Total Fees $900 00 Total Payments To Date $900 00 Balance Due $000 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION r"* ;C5ITY OF CARLSBAD BUILDING DEPARTMENT '1635 Faraday Ave , Carlsbad, CA 92008 1 PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK NO EST VAL Plan Ck Deposit Validated By Date y I / Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor s Parcel #Existing Use Proposed Use K ^ DescriptJO/J of Work^L<X 2 CONTACT PERSON (if different from applicant) /-\ VB #of Stones # c/ Bedrooms # of Bathrooms Name f^lVV P-AO^IAddress /C/ V i City 3 APPLICANT tZ) Contractor O Agent for Contractor £9 Owner Q Agent for Owner State/Zip t*fs/f Telephone #Fax # Name 4 PROPERTY OWNER Address City State/Zip Telephone # Aritiress o uura i nMi> i un uuivirMnT IMMIVIC \ «> >y ^*~* SF'A/'A -^~» (Sec 7031 5 Business and Professions Cod^TCny""Cily~or CoJnt^Kwnich retjui City State/Zip Telephone #Name 5 CONTRACTOR COMPANY NAME to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law IChapter 9 commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars |$500|) Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name State License # Address City State/Zip Telephone 6 WORKERS COMPENSATION Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations l~1 I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued f~l I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker s compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) Q CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 000} in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE DATE 7 OWNER BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor s License Law for the following reason f~l I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) f~l I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) [~l I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement O YES |~|NO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR NON RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act7 D YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' d YES Q NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? D YES Q NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 8 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER S NAME LENDER S ADDRESS APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned . . at any tims after the work is commf»«e^d for a peood of 180 days (Section 106 4 4 Uniform Building Code) ^t APPLICAM i S SIGNATURE \V C*~-f p-^ DATE -2 '22 ~0 1 ^ ^ WHITE File YELLOW Applicant PINK Finance EsGil Corporation • -- =— In Partnership untfi. government for Quitting Safety DATE March 22, 2007 JURISDICTION Carlsbad a PLANREVIEWER -^3" hlLt PLAN CHECK NO PCR07-40(05-2057.REV) SET IV PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Structural Rev. for Baum Residence Addition/Remodel • The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS By Kurt Culver for B.D Enclosures Esgil Corporation GA D MB D EJ D PC 3/21/07 tmsmtl dot 9320 Chesapeake Drive, Suite 208 + San Diego California 92123 4 (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In {Partners/up vnth government for 'BuiCding Safety DATE March 21, 2007 a APPLICANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO PCR07-40(05-2057 REV) SET II PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Structural Rev. for Baum Residence Addition/Remodel I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I | The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person H The applicant's copy of the check list has been sent to Ray Baum 1014 Tulip Way, Carlsbad, CA 92011 Esgil Corporation staff dud not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Ray Telephone # 760 931 6797 Date contacted 3A//6^by^^ ) Fax# 760722-3148 Mail v Telephone Fax i/ln Person REMARKS By Kurt Culver for B.D. Enclosures Esgil Corporation D GA n MB D EJ D PC 3/19/07 trnsmtl dot 9320 Chesapeake Drive Suite 208 * San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 Carlsbad PCRO7-4O(O5-2057 REV) March 21, 2007 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad 2057 REV) PROJECT ADDRESS 1014 Tulip Way DATE PLAN RECEIVED BY ESGIL CORPORATION 3/19/07 REVIEWED BY Kurt Culver for B D. PLAN CHECK NO PCRO7-40(05- SET II DATE RECHECK COMPLETED March 21, 2007 FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans B The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items C Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list9 QYes GNo Carlsbad PCR07-40(05-2057 REV) March 21, 2007 Note The following unresolved issues were discussed with the engineer on 3/20/07 EsGil Corporation is awaiting revised plans and calculations, as agreed upon by the engineer • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, and (760) 602- 2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 Final plans, specifications and calculations shall be signed and sealed by the engineer or architect licensed by the State of California who is responsible for their preparation Specify expiration date of license (California Business and Professions Code) 3 On the cover sheet of the plans, specify any items that will havo a doforrod submittal (trussos. otc ) Additionally, provide the following note on the plans, por UBC Soc 106312 "Submittal documents for deferred submittal items shall bo submitted to tho architect or engineer of record, who shall review them and forward thorn to tho building official with a notation indicating that the deferred submittal documents have boen roviowed and that they have boon found to be in general conformance with the design of tho building Tho deferred submittal itoms shall NOT bo installed until thoir design and submittal documents have boon approved by the building official" • FOUNDATION REQUIREMENTS A All now residential buildings, including additions, require a soils report An update letter is required if the report is moro than 3 years old—If a room addition is less than 1000 sq ft in area and only one story, then a soils report is not required § Provide a copy of tho project soil report prepared by a California licensed architect or civil engmoor The report shall include foundation design recommondations based on the Carlsbad PCRO7-40(05-2057 REV) March 21, 2007 ongmoer's findings and shall comply with DBG Section 1804 € In Soismic Zone 4, each site shall be assigned a noar-source factor Identify this value in the soils report and on the plans—Section 1629 4 2 7 Investigate the potential for seismically induced soil liquefaction and soil instability in Soismic Zones 3 and 4—This does not apply to detached, single-story dwellings Section 18045 S Note on tho plan tho soils classification, whothor or not tho soil is oxpansivo and noto tho allowable bearing value Section 106 3 3 8 Provide a letter from tho soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has boen dotormmod that the rocommendations in the soils report aro properly incorporated into the construction documents (when required by tho soil report) • FRAMING 40 Provide truss details and truss calculations for this project Specify truss identification numbers on tho plans Or submit a doforral PLEASE SEE ITEM 3 ABOVE 44 PLEASE Show DETAIL FOR THE drag TRUSS CONNECTION TO THE RESPECTIVE RESISTING ELEMENTS PLEASE CROSS REFERENCE THE SAME TO THE FRAMING PLANS PLEASE SEE THE DRAG TRUSSES SHOWN ON THE LINE 3 4 ON SHEET S-3 1 42- IT SEEMS THAT THE RB13 WALL LINE WOULD BE DRAGGED INTO THE RB21 SYSTEM PLEASE SHOW CONNECTION DETAIL OF SUCH DRAG SYSTEM ON THE PLANS AND CROSS REFERENCED TO THE FRAMING PLAN 13 THE LINES B & 5 LATERAL LOAD OF THE UPPER LEFT ROOF SEEMS NOT INCLUDED IN THE LOWER ROOF LOAD PLEASE SEE THE OTHER LINES ALSO THIS COMMENT MAY AFFECT THE DIAPHRAGMS, CHORDS AND THE SHEAR WALLS ALL THE WAY TO THE FOUNDATION 44 PLEASE SUBMIT COMPLETE DIAPHRAGM & DIAPHRAGM CHORDS CALCULATIONS 15 LINE E MAY NEED A DRAG COLLECTOR TO TRANSMIT THE TRIBUTARY LOAD SHOWN ON SHEET S3 1 AS INDICATED IN THE CALCULATIONS PLEASE SHOW CONNECTION DETAIL OF SUCH DRAG SYSTEM ON THE PLANS AND CROSS REFERENCED TO THE FRAMING PLAN 46 A COMPLETE PLAN CHECK WHEN ALL THE ITEMS ABOVE ARE MET Carlsbad PCR07-40(05-2057.REV) March 21, 2007 • MISCELLANEOUS 47 Ploaso SUBMIT CALCULATIONS FOR THE FOUNDATIONS TO VERIFY THE OVERTURNING EFFECT OF THE LATERAL LOAD TO THE SOILS BEARING CAPACITY To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact BERT DOMINGO at Esgil Corporation Thank you EsGii Corporation In Partnership with government for <Buihfmg Safety DATE March 6, 2OO7 a APPIJCANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO PCR07-40(05-2057.REV) SET I PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Structural Rev. for Baum Residence Addition/ Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Ray Baum 1014 Tulip Way, Carlsbad, CA 92011 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Ray Telephone # 760 931 6797/ / / Date contacted 3n/<f](^.^-^S) Fax # 760 722-3148 Mail Telephone {/"Fax Hn Person REMARKS By Bert Domingo Enclosures Esgil Corporation GA D MB D EJ D PC 2/23/07 trnsmtl dot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad PCR07-40(05-2057 REV) March 6, 2007 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad 2057 REV) PROJECT ADDRESS 1014 Tulip Way DATE PLAN RECEIVED BY ESGIL CORPORATION 2/23/07 REVIEWED BY Bert Domingo PLAN CHECK NO PCR07-4O(05- SET I DATE RECHECK COMPLETED March 6, 2007 FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo Carlsbad PCRO7-40(05-2O57 REV) March 6, 2007 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, and (760) 602- 2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 Final plans, specifications and calculations shall be signed and sealed by the engineer or architect licensed by the State of California who is responsible for their preparation Specify expiration date of license (California Business and Professions Code) 3 On the cover sheet of the plans, specify any items that will have a deferred submittal (trusses, etc ) Additionally, provide the following note on the plans, per UBC Sec 106342 "Submittal documents for deferred submittal items shall be submitted to the architect or engineer of record, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official" • FOUNDATION REQUIREMENTS 4 All new residential buildings, including additions, require a soils report An update letter is required if the report is more than 3 years old If a room addition is less than 1000 sq ft in area and only one story, then a soils report is not required 5 Provide a copy of the project soil report prepared by a California licensed architect or civil engineer The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804 6 In Seismic Zone 4, each site shall be assigned a near-source factor Identify this value in the soils report and on the plans Section 1629 4 2 Carlsbad PCRO7-40(O5-2O57.REV) March 6, 20O7 7 Investigate the potential for seismically induced soil liquefaction and soil instability in Seismic Zones 3 and 4 This does not apply to detached, single-story dwellings Section 18045 8 Note on the plan the soils classification, whether or not the soil is expansive and note the allowable bearing value Section 106 3 3 9 Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report) • FRAMING 10 Provide truss details and truss calculations for this project Specify truss identification numbers on the plans Or submit a deferral PLEASE SEE ITEM 3 ABOVE 11 PLEASE Show DETAIL FOR THE drag TRUSS CONNECTION TO THE RESPECTIVE RESISTING ELEMENTS PLEASE CROSS REFERENCE THE SAME TO THE FRAMING PLANS PLEASE SEE THE DRAG TRUSSES SHOWN ON THE LINE 3 4 ON SHEET S-3 1 12 IT SEEMS THAT THE RB13 WALL LINE WOULD BE DRAGGED INTO THE RB21 SYSTEM PLEASE SHOW CONNECTION DETAIL OF SUCH DRAG SYSTEM ON THE PLANS AND CROSS REFERENCED TO THE FRAMING PLAN 13 THE LINES B & 5 LATERAL LOAD OF THE UPPER LEFT ROOF SEEMS NOT INCLUDED IN THE LOWER ROOF LOAD PLEASE SEE THE OTHER LINES ALSO THIS COMMENT MAY AFFECT THE DIAPHRAGMS, CHORDS AND THE SHEAR WALLS ALL THE WAY TO THE FOUNDATION 14 PLEASE SUBMIT COMPLETE DIAPHRAGM & DIAPHRAGM CHORDS CALCULATIONS 15 LINE E MAY NEED A DRAG COLLECTOR TO TRANSMIT THE TRIBUTARY LOAD SHOWN ON SHEET S3 1 AS INDICATED IN THE CALCULATIONS PLEASE SHOW CONNECTION DETAIL OF SUCH DRAG SYSTEM ON THE PLANS AND CROSS REFERENCED TO THE FRAMING PLAN 16 A COMPLETE PLAN CHECK WHEN ALL THE ITEMS ABOVE ARE MET • MISCELLANEOUS 17 Please SUBMIT CALCULATIONS FOR THE FOUNDATIONS TO VERIFY THE OVERTURNING EFFECT OF THE LATERAL LOAD TO THE SOILS BEARING CAPACITY Carlsbad PCR07-40(05-2O57 REV) March 6, 2O07 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact BERT DOMINGO at Esgil Corporation Thank you Carlsbad PCR07-40(05-2057 REV) March 6, 2O07 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO PCR07-4O(O5 2057.REV) PREPARED BY Bert Domingo DATE March 6, 2007 BUILDING ADDRESS 1014 Tulip Way BUILDING OCCUPANCY r3 TYPE OF CONSTRUCTION VN BUILDING PORTION Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) cb Rlrln Pprmit FPP hu Orrfmsnrp 1 ^ Valuation Multiplier By Ordinance Reg Mod VALUE ($) Plan Check Fee by Ordinance $900 001 Type of Review Repetitive FeeRepeats D Complete Review D Other m Hourly 75 Structural Only Hours Esgil Plan Review Fee $720 00 * Based on hourly rate Comments Sheet 1 of 1 macvalue doc Servln Engineering* Inc. 2382 Cammo Vida Roble, Suite F Carlsbad, CA 92011 (760)931-1792, Fax (760)931-1892 Email nservmffi.servin-engmeering com February 21,2007 Esgil Corporation 9230 Chesapeake Drive, Suite 208 San Diego, California 92123 Attention Kurt Culver 858-560-1468, 858-560-1576 Fax Regarding PCF06-116 (Original 05-2057) 1014 Tulip for Ray Baum, Remodel and addition Dear Kurt I'd like to express my gratitude and pleasure on the last review that Burt Domingo did on this project I'm sure that we won't have that problem again The reason for this letter is two fold, 1) The owner wants to make a change on the structure after speaking with his contractor and consulting with us regarding the increased costs due to the last change, 2) Provide you with a bnef descnption of the proposed change In the last revision we placed some steel columns to transfer the lateral loading to the lower floor and foundation system In this revision, we've kept one moment frame and proposed to eliminate the steel columns providing lateral restraint for the middle diaphragm This is accomplished by providing the shear walls along the affected grid lines with proper shear transfer to the lower diaphragms and shear walls The attached revision summary itemizes the essence of this project change Again, its due to the limited budget and delays for my client We've made the revisions to comply with his wishes and his contractor's suggestions in compliance with the building code Please review these suggestions and comments if necessary As always, your review process is excellent and efficient We welcome your suggestions Sincerely yours, NICK SERVIN, PE, Principal Engineer #33538 \\S ervmeng\data\j ohn\D\Jobs\Tuhp\Esgil2 wpd Revision Summary • Replace the steel cantilever columns along grid lines 2, 3, B, &D with plywood shearwalls at the two curve walls • The curve wall along grid line 2 is a balloon frame wall (24ft) with 2x8 studs that resist the shear from the upper roof and two HD8A holdowns are provided • The curve wall along grid line 3 and B is a 5ft shearwall that resist the shear from the upper roof and is supported by two 4x10 beams with the walls strapped to the beams The beams are connected to the post with Simpson column caps (CCQ series) That transfers down to the foundation with the post at the foundation being held down with HD5A holdowns • The curve wall along gnd line 3 and D is an 8ft shearwall that resist the shear from the upper roof and is supported by a 4x10 beam and a 5 1/4" x 16" parallam beam The wall is strapped to the beams with Simpson cmstc!6 straps and the beams are connected to the post with Simpson column caps (CCQ series) At the foundation the post are held down with HD5A holdowns Summary These shearwalls are to replace the steel cantilever columns These shearwalls are to resist the shear at the upper roof The left lower roof diaphragm and the right lower roof diaphragm are resisted by its own lateral force resisting system ^Sr•^-^^'^"?GN^TJsr r*-o T i — o ;c CD ^S. o m > 2S Jo < c § 05 S i| 03 m m oo Im Cfl > 5 12-14-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No PCR06116 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title 1014 TULIP WYCBAD PCR 2144101200 Lot# 0 $0 00 Construction Type VN BAUM RES-REV ERROR-IN REAR SET Status Applied Entered By Plan Approved Issued Inspect Area EXTEND 2ND STORY IN FRONT TO LINE UP W/1ST FLOOR Applicant BAUM RAYMOND C 1014 TULIP WAY CARLSBAD CA 92011 Owner BAUM RAYMOND C 1014 TULIP WAY CARLSBAD CA 92011 ISSUED 07/03/2006 RMA 12/14/2006 12/14/2006 Plan Check Revision Fee Additional Fees $960 00 $000 Total Fees $960 00 Total Payments To Date $960 00 Balance Due $000 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK Plan Ck Deposit Validated By r PROJECT INFORMATION Business Name (at this address)Address (include Bldg/Suite it) Subdivision Name/NumberLegal Description Assessor s Parcel # ,101*4 Tuh Name 3 APPLICANT Q Contractor Address ' d City Agent for^ Contractor D Owner fj Agent for Owner Fax # Name 4 PROPERTY OWNER Address City State/Zip Telephone ff Name Address City State/Zip Telephone # 5 CONTRACTOR - COMPANY NAME , - "" *i - (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001) Name State License # Address License Class City State/Zip City Business License # Telephone tt Designer Name Address City State/Zip Telephone State License # _ 6 , ..WORKERS" COMPENSAT ION ....... •* , .... ' '" , ~'": "• : ..... °' s;. . J Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations D I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued C] I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker s compensation insurance carrier and policy number are Insurance Company _ Policy No _ Expiration Date _ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) n CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE _ ______ __ __ DATE _ 7 -OWNER BUILDER DECLARATION ; ..* " i h » I hereby affirm that I am exempt from the Contractor s License Law for the following reason n I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Cods The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) CD I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) CD I am exempt under Section _ Business and Professions Code tor this reason YES1 I personally plan to provide the major labor and materials for construction of the proposed property improvement 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / contractors license number) ___ __ 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type gf work) _ PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY , : > , * ; Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? O YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' Q YES Q NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? O YES Q NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 8 CONSTRUCTION LENDING AGENCY i I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER S NAME LENDER S ADDRESS 9 APPLICANT CERTIFICATION ; : ~ ~~ \ '• :' I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for rfj^i&nA 180 days (Section 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE V WHITE File YELLOW Applicant PINK Finance DATE Ray Baum 1014 Tulip Way Carlsbad, CA 92011 June 28, 2006 Re Revisions to Permit # CB05-2057 To Whom It May Concern I have severed my relationship with Bill Perry architect of record on the above reference remodel of my home I assume all responsibility for the design changes as of this date John Gomez of J-Tek design was employed as a draftsman only, and made changes to the design on my request The engineer, Servin Engineering, remains the same Thank you for taking the time to review my revision plans Sincerely, Ray Baum Owner Ray Baum 1014 Tulip Way Carlsbad, CA 92011 Regarding Revisions to plans permit #CB05-2507 The overall concept of the project remains the same but some things had to be corrected in order to build the house Therefore, at first glance it may be hard to see the differences between the old and the new Because the architect basically did everything on just three pages, we decided to just add submittal pages to correct the onginal work For instance, we could not just replace the first floor plan as it was also the electrical page We have added extra pages to show the new dimensions and layout Because the original work needed structural revisions we had Servm Engineering, the original engineers, go though and recalculate the entire project These revisions include new plans, revised set of calculations, and a new title 24 Besides a few cosmetic changes there were only two areas that needed changing 1 The architect of record refused to change the radius of the stairwell Consequently the stairwell tower encroached into the rear set back by over a foot We have reduced the radius of the rear tower which also made the two adjacent rear walls slightly longer 2 The next problem that we could not get the architect to address was the second story on the front of the house It was set to far back over the first floor If one walked to the front door, and looked up from the inside, you would see sky rather than the second floor Obviously we had to change the radius of the front tower to match the radius of the rear tower We then moved the front walls of the second story forward to cover the first floor, also allowing the bathrooms to share a common wall for water, waste, and venting Thank you in advance for taking the time to review this submittal Respectfully, Ray Baum Property Owner EsGil Corporation In (Partnership with government for (RmCtfing Safety DATE December 8, 2006 a APPLICANT B JURIS JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO PCR06-116(Orig.O5-2057) SET IX PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Revisions for Baums SFD The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person [El REMARKS 1) PLEASE HAVE THE ENGINEER OF WORK TO COMPLETE THE SPECIAL INSPECTION FORM(CAISSONS, WELDING, SOILS EPOXY, ETC) 2) PLEASE HAVE THE DESIGNER SLIP SHEET THE STRUCTURAL DRAWINGS TO THE CITY SET VII By Bert Domingo Enclosures Esgil Corporation D GA D MB D EJ D PC 12/5/06 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 EsGil Corporation In (Partnership with government for (Building Safety DATE November 30, 2006 JURISDICTION Carlsbad PLAN CHECK NO PCR06-116 (Orig 05-2057) SET VIII PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Revisions for Baum Residence Addition and Remodel OPET^TREVIEWER a FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Ray Baum 1014 Tulip Way, Carlsbad, CA 92011 I | Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Ray Baum Telephone # 760-931-6797 Date contacted l2./i/ofc(by ££. ) Fax # 760-722-3148 Mail Telephone ^ Fax *-^ln Person I REMARKS By Bert Domingo Esgil Corporation D GA D MB D EJ Enclosures PC 11/20/06 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad PCR06-116 (Ong.05-2057) November 30, 2006 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad (Orig.O5-2057) PROJECT ADDRESS 1014 Tulip Way DATE PLAN RECEIVED BY ESGIL CORPORATION 11/20/06 REVIEWED BY Bert Domingo PLAN CHECK NO PCRO6-116 SET VIII DATE RECHECK COMPLETED November 30, 2006 FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to THE JURISDICTION'S BUILDING DEPARTMENT B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo Carlsbad PCR06-116 (Ong.05-2057) November 30, 2OO6 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments 2 Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation Specify expiration date of license (California Business and Professions Code) THIS WILL BE CHECKED WHEN ALL THE ITEMS BELOW ARE MET 3 Show how the shear load on the 2nd floor would be transferred thru the openings (above the living room and stairwell) to the resisting elements The response references details 7 & 9/S-6 showing straps to plates? But did not show how the lateral loads will be transferred to the resisting elements Please submit complete analyses reflecting diaphragm loading and load path all the way to the foundation AGAIN, PLEASE SUBMIT COMPLETE ANALYSIS REFLECTING THE DIAPHRAGM LOADINGS AND LOAD PATH ALL THE WAY TO THE FOUNDATION PLEASE SEE THE FOLLOWING CORRECTIONS ALSO A) THE FOLLOWING COMMENTS ARE JUST EXAMPLE OF CONFLICTING STRUCTURAL DATA SHOWN IN THE CALCULATIONS AND COMPARED WITH THE ELEMENTS SHOWN ON THE PLANS 1) THE MOMENT OF THE BASE FOR THE STEEL COLUMNS SHOWN ON PAGE L-27 IS DIFFERENT THAN WHAT WAS USED IN THE DESIGN OF THE STEEL COLUMNS SHOWN ON PAGES L-25 AND 26. 2) THE STEEL COLUMN AS A RESISTING ELEMENT LOCATED ALONG LINE 3 25 @ LINE D AND BEING SUPPORTED BY STEEL BEAM AT THE FLOOR LEVEL CONNECTED TO A WOOD POST @ ONE END AND NOT CLEAR HOW IT IS SUPPORTED ON THE OTHER END 3) THE ORIGINAL CORRECTION ITEM 3 ABOVE HAD NOT BEEN RESPONDED TO Carlsbad PCR06-116 (Orig.05-2057) November 3O, 2OO6 4) A COMPLETE STRUCTURAL PLAN CHECK WILL BE MADE On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below Section 106 3 2 IT SEEMS NOT RESPONDED TO STILL NOT RESPONDED TO THIS WILL BE CHECKED WHEN THE NEW STRUCTURAL COMMENTS WERE MET • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED'? REMARKS FIELD WELDING CONCRETE EXPANSION/EPOXY ANCHORS PILES/CAISSONS When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached form IT SEEMS THAT THE FORM DID NOT INCLUDE THE CONCRETE AND THE HS BOLTS PLEASE SEE ITEM 4 ABOVE To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation Thank you EsGil Corporation In Partnership witfi government for (Bmfding Safety DATE October 31, 2006 JURISDICTION Carlsbad a FILE PLAN CHECK NO PCR06-116 (Orig.05-2057) SET VII PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Revisions for Baum Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Ray Baum 1014 Tulip Way, Carlsbad, CA 92011 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Ray Baum Telephone # 760-931-6797 Date contacted //l>/b(j> (by F-A^) Fax # 760-722-3148 MaiL/- Telephone Fax^ In Person REMARKS THE PLANS SUBMITTED FOR CB05-2057 WENT THRU 6 PLAN CHECKS AND THE SAME PLANS UNDER CBPCR06-116 IS NOW GOING TO THE 8™ PLAN CHECK THE LATERAL SYSTEM HAVE BEEN CHANGING EVERY PLAN CHECK TIME FOR THE LAST 4 PLAN CHECK SCHEDULE THIS IS BECOMING UNACCEPTABLE THE CALCULATIONS INCLUDED IN THE LATEST SUBMITTAL IS VERY CONFUSING THE DATA SHOWN ON PAGE L-31 ARE DIFFERENT THAN WHAT IS SHOWN ON PAGE L-32 PAGE L33 IS COMPLETELY DIFFERENT DATA AND SO ON WE CAN NOT CHECK THE PLANS UNTIL THE ENGINEER OF WORK WOULD KINDLY COME TO THIS OFFICE TO PLEASE GUIDE/CLARIFY THE CONFUSION By Bert Domingo Enclosures Esgil Corporation D GA D MB D EJ D PC 10/20/06 trnsmtldot 9320 Chesapeake Drive, Suite 208 *• San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad PCRO6-116 (Orig 05-2057) October 31, 2OO6 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad (Orig.O5-2O57) PROJECT ADDRESS 1014 Tulip Way DATE PLAN RECEIVED BY ESGIL CORPORATION 10/20/06 REVIEWED BY Bert Domingo PLAN CHECK NO PCRO6-116 SET VII DATE RECHECK COMPLETED October 31, 2006 FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to THE JURISDICTION'S BUILDING DEPARTMENT B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo Carlsbad PCR06-116 (Orig O5-2O57) October 31, 2006 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments 2 PJans. specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation Specify expiration date of license (California Business and Professions Code! 3 Show how the shear load on the 2nd floor would be transferred thru the openings (above the living room and stairwell) to the resisting elements The response references details 7 & 9/S-6 showing straps to plates9 But did not show how the lateral loads will be transferred to the resisting elements Please submit complete analyses reflecting diaphragm loading and load path all the way to the foundation AGAIN, PLEASE SUBMIT COMPLETE ANALYSIS REFLECTING THE DIAPHRAGM LOADINGS AND LOAD PATH ALL THE WAY TO THE FOUNDATION PLEASE SEE THE FOLLOWING CORRECTIONS ALSO A) THE CALCULATIONS INDICATED WIND GOVERNS BUT THERE SEEMS NO SEISMIC ANALYSIS WERE SUBMITTED TO COMPARE WITH IT SEEMS THAT A NEW LATERAL SYSTEM IS BEING PROPOSED PLEASE SEE THE FOLLOWING CORRECTIONS 1) THE SYSTEM ALONG LINE 2 SEEMS TO INDICATE TWO CANTILEVERED COLUMNS PLEASE SEE THE FOLLOWING COMMENTS FOR COMPLIANCE a) PAGE L12 SHOWS A MOMENT AT THE BASE OF THE COLUMN BUT SEEMS NOT COMPATIBLE WITH THE SUM OF THE PRODUCT OF THE FORCES AND THE RESPECTIVE MOMENT ARMS PLEASE CLARIFY b) PER TABLE 16N OF THE 97 UBC, THE B OF THE SYSTEM SHOULD BE 2 2 Carlsbad PCR06-116 (Orig.O5-2O57) October 31, 2006 c) THERE SEEMS NO CALCULATIONS FOR THE FOUNDATION OF THE SYSTEM TO CARRY/RESIST THE HORIZONTAL FORCES AND THE OVERTURNING EFFECT OF SUCH HORIZONTAL/LATERAL LOADS PLEASE SUBMIT CALCULATIONS d) THE ABOVE COMMENTS IS ALSO TRUE TO THE COLUMN SHOWN ON PAGE L13 e) WITH THE APPLICATION OF THE R = 2 2 AND THE REAL MOMENT AT THE BASE, THE BASE PLATES, ANCHOR BOLTS AND THE FOUNDATION COULD BE AFFECTED f) PLEASE SHOW HOW THE BOLT VALUE (ALLOWABLE) WAS DERIVED g) PLEASE SHOW HOW THE BOLT ANCHORAGE WOULD MEET THE REQUIREMENTS OF THE SECTION 1923 OF THE 97UBC 2) PAGE L16 OF THE CALCULATIONS SHOWS A STEEL COLUMN ALONG LINE 3 WITH HORIZONTAL AND VERTICAL LOADS AT THE TOP AND A DRAG TRUSS (FORCE?) AT 5' BELOW THE TOP BUT IT IS NOT CLEAR HOW EQUILIBRIUM COULD BE ATTAINED WITH THE BOTTOM OF THE COLUMN ON A PIN - PIN CONNECTION IS THE SAME COLUMN A PART OF THE RESISTING ELEMENTS OF THE BUILDING? 3) LINE B SHOWS A SHEARWALL8( 9' LONG) AT THE LOWER LEFT ROOF BUT IT IS NOT CLEAR HOW THE TRIBUTARY LOAD WOULD BE TRANSFERRED TO SUCH RESISTING ELEMENT AT THE SAME LEVEL, ALONG LINE D, THERE SEEMS NO RESISTING ELEMENT TO CARRY THE LATERAL LOAD FROM THE UPPER ROOF TO THE FOUNDATION 4) IN VIEW OF THE ABOVE, THE CALCULATIONS AND THE STRUCTURAL PLANS ARE CONFUSING TO MAKE A COMPREHENSIVE PLAN CHECK PROCESS Carlsbad PCRO6-116 (Ong.O5-2O57) October 31, 2OO6 5) IT SEEMS THAT THE ORIGINAL CORRECTION ITEM 3 ABOVE HAD NOT BEEN RESPONDED TO 6) A COMPLETE STRUCTURAL PLAN CHECK WILL BE MADE 7) AGAIN THE LATERAL SYSTEM OF THE BUILDING HAS BEEN CHANGING SO MANY TIMES MAY CHARGE ADDITIONAL FEE AGAIN On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below Section 106 3 2 IT SEEMS NOT RESPONDED TO STILL NOT RESPONDED TO THIS WILL BE CHECKED WHEN THE NEW STRUCTURAL COMMENTS WERE MET • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED'? REMARKS FIELD WELDING SPECIAL MOMENT FRAME CONNECTIONS (SEISMIC ZONES 3 & 4 ONLY) CONCRETE HIGH-STRENGTH BOLTS EXPANSION/EPOXY ANCHORS When special inspection is required the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached form IT SEEMS THAT THE FORM DID NOT INCLUDE THE CONCRETE AND THE HS BOLTS PLEASE SEE ITEM 4 ABOVE Carlsbad PCRO6-116 (Orig O5-2057) October 31, 20O6 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation Thank you EsGii Corporation In Partnership with government for (Buibting Safety DATE October 6, 2006 a APPLICANT JURISDICTION Carlsbad /a PLAN REVIEWER a FILE PLAN CHECK NO PCR06-116 (Orig 05-2057) SET VI PROJECT ADDRESS 1O14 Tulip Way PROJECT NAME Revisions for Baum Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Ray Baum 1014 Tulip Way, Carlsbad, CA 92011 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Ray Baum Telephone # 760-931-6797 Date contacted (Mfy (by fl^) Fax # 760-722-3148 Mail"—Telephone Fax In Person REMARKS AN ADDITIONAL PLAN CHECK FEE IS ASSESSED FOR THIS PROJECT BECAUSE THE LATERAL SYSTEM HAVE BEEN CHANGING EVERY PLAN CHECK TIME FOR THE LAST 3 PLAN CHECK SCHEDULE By Bert Domingo Enclosures Esgil Corporation D GA D MB D EJ D PC 9/14/06 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad PCR06-116 (Ong.O5-2O57) October 6, 2006 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO PCR06-116 (Ong.O5-2O57) PROJECT ADDRESS 1014 Tulip Way SET VI DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 9/14/06 October 6, 20O6 REVIEWED BY Steve Sanders for Bert Domingo & Bill Elizarraras FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to THE JURISDICTION'S BUILDING DEPARTMENT B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? UYes QNo Carlsbad PCR06-116 (Orig 05-2O57) October 6, 2O06 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments 2 Plans, specifications and calculations shall be signed and sealed bvthe California state licensed engineer or architect responsible for their preparation Specify expiration date of license (California Business and Professions Code) 3 Show how the shear load on the 2nd floor would be transferred thru the openings (above the living room and stairwell) to the resisting elements The response references details 7 & 9/S-6 showing straps to plates'? But did not show how the lateral loads will be transferred to the resisting elements Please submit complete analyses reflecting diaphragm loading and load path all the way to the foundation AGAIN, PLEASE SUBMIT COMPLETE ANALYSIS REFLECTING THE DIAPHRAGM LOADINGS AND LOAD PATH ALL THE WAY TO THE FOUNDATION PLEASE SEE THE FOLLOWING CORRECTIONS ALSO •f-, A) THE CALCULATIONS INDICATED WIND GOVERNS BUT THERE SEEMS NO SEISMIC ANALYSIS WERE SUBMITTED TO COMPARE WITH IT SEEMS THAT A NEW LATERAL SYSTEM IS BEING PROPOSED PLEASE SEE THE FOLLOWING CORRECTIONS 1) THE SYSTEM ALONG LINE 2 SEEMS TO INDICATE TWO CANTILEVERED COLUMNS PLEASE SEE THE FOLLOWING COMMENTS FOR COMPLIANCE a) PAGE L12 SHOWS A MOMENT AT THE BASE OF THE COLUMN BUT SEEMS NOT COMPATIBLE WITH THE SUM OF THE PRODUCT OF THE FORCES AND THE RESPECTIVE MOMENT ARMS PLEASE CLARIFY b) PER TABLE 16N OF THE 97 UBC, THE R OF THE SYSTEM SHOULD BE 2 2 Carlsbad PCR06-116 (Orig.05-2O57) October 6, 2006 c) THERE SEEMS NO CALCULATIONS FOR THE FOUNDATION OF THE SYSTEM TO CARRY/RESIST THE HORIZONTAL FORCES AND THE OVERTURNING EFFECT OF SUCH HORIZONTAL/LATERAL LOADS PLEASE SUBMIT CALCULATIONS d) THE ABOVE COMMENTS IS ALSO TRUE TO THE COLUMN SHOWN ON PAGE L13 e) WITH THE APPLICATION OF THE R = 2 2 AND THE REAL MOMENT AT THE BASE, THE BASE PLATES, ANCHOR BOLTS AND THE FOUNDATION COULD BE AFFECTED f) PLEASE SHOW HOW THE BOLT VALUE (ALLOWABLE) WAS DERIVED g) PLEASE SHOW HOW THE BOLT ANCHORAGE WOULD MEET THE REQUIREMENTS OF THE SECTION 1923 OF THE 97UBC 2) PAGE L16 OF THE CALCULATIONS SHOWS A STEEL COLUMN ALONG LINE 3 WITH HORIZONTAL AND VERTICAL LOADS AT THE TOP AND A DRAG TRUSS (FORCE?) AT 5' BELOW THE TOP BUT IT IS NOT CLEAR HOW EQUILIBRIUM COULD BE ATTAINED WITH THE BOTTOM OF THE COLUMN ON A PIN - PIN CONNECTION IS THE SAME COLUMN A PART OF THE RESISTING ELEMENTS OF THE BUILDING? 3) LINE B SHOWS A SHEARWALL8( 9' LONG) AT THE LOWER LEFT ROOF BUT IT IS NOT CLEAR HOW THE TRIBUTARY LOAD WOULD BE TRANSFERRED TO SUCH RESISTING ELEMENT AT THE SAME LEVEL, ALONG LINE D, THERE SEEMS NO RESISTING ELEMENT TO CARRY THE LATERAL LOAD FROM THE UPPER ROOF TO THE FOUNDATION 4) IN VIEW OF THE ABOVE, THE CALCULATIONS AND THE STRUCTURAL PLANS ARE CONFUSING TO MAKE A COMPREHENSIVE PLAN CHECK PROCESS Carlsbad PCRO6-116 (Orig O5-2057) October 6, 2OO6 5) IT SEEMS THAT THE ORIGINAL CORRECTION ITEM 3 ABOVE HAD NOT BEEN RESPONDED TO 6) A COMPLETE STRUCTURAL PLAN CHECK WILL BE MADE 7) AGAIN THE LATERAL SYSTEM OF THE BUILDING HAS BEEN CHANGING SO MANY TIMES MAY CHARGE ADDITIONAL FEE AGAIN On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below Section 106 3 2 IT SEEMS NOT RESPONDED TO STILL NOT RESPONDED TO THIS WILL BE CHECKED WHEN THE NEW STRUCTURAL COMMENTS WERE MET . REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED'? REMARKS FIELD WELDING SPECIAL MOMENT FRAME CONNECTIONS (SEISMIC ZONES 3 & 4 ONLY) CONCRETE HIGH-STRENGTH BOLTS EXPANSION/EPOXY ANCHORS When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached form IT SEEMS THAT THE FORM DID NOT INCLUDE THE CONCRETE AND THE HS BOLTS PLEASE SEE ITEM 4 ABOVE Carlsbad PCR06-116 (Orig 05-2057) October 6, 2006 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation Thank you Carlsbad PCRO6-116 (Orig O5-2O57) October 6, 2006 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad (Ong.O5-2O57) PLAN CHECK NO PCR06-116 PREPARED BY Steve Sanders for Bert Domingo & Bill Elizarraras October 6, 2006 BUILDING ADDRESS 1014 Tulip Way BUILDING OCCUPANCY R3 TYPE OF CONSTRUCTION VN DATE BUILDING PORTION Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) cb Rlrin Pprmif FPP hu Orrlmanrp 'W Valuation Multiplier By Ordinance Reg Mod VALUE ($) Plan Check Fee by Ordinance Type of Review D Complete Review $600 00 L~] Repetitive Fee~y-_H Repeats D Other r-i Hourly Structural Only Hours Esgil Plan Review Fee $480 00 * Based on hourly rate Comments Sheet 1 of 1 macvalue doc EsGil Corporation In (Partnership with government for (BuiCcfing Safety DATE September 21, 2006 JURIS JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO PCR06-116 (Orig 05-2057) SET V PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Revisions for Baum Residence Addition and Remodel | | The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck [XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person [X] The applicant's copy of the check list has been sent to Ray Baum 1014 Tulip Way, Carlsbad, CA 92011 I | Esgil Corporation staff did not advise the applicant that the plan check has been completed [XJ Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Ray Baum Telephone # 760-931-6797/ / fl X5 Date contacted^/Z^o^ (by&=$ Fax # 760-722-3148 Mail Telephone Fax l/ln Person REMARKS By Steve Sanders for Bert Domingo & Bill Ehzarraras Enclosures Esgil Corporation D GA D MB D EJ D PC 9/14/06 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad PCRO6-116 (Orig 05-2057) September 21, 2OO6 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO PCR06-116 (Orig 05-2O57) PROJECT ADDRESS 1014 Tulip Way SET V DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 9/14/06 September 21, 2O06 REVIEWED BY Steve Sanders for Bert Domingo & Bill Elizarraras FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to THE JURISDICTION'S BUILDING DEPARTMENT B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo Cai-lsbad PCRO6-116 (Orig 05-2O57) September 21, 2OO6 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments 2 Plans, specifications and calculations shall be signed and sealed bv the California state licensed engineer or architect responsible for their preparation Specify expiration date of license (California Business and Professions Code) 3 Show how the shear load on the 2nd floor would be transferred thru the openings (above the living room and stairwell) to the resisting elements The response references details 7 & 9/S-6 showing straps to plates7 But did not show how the lateral loads will be transferred to the resisting elements Please submit complete analyses reflecting diaphragm loading and load path all the way to the foundation AGAIN. PLEASE SUBMIT COMPLETE ANALYSIS REFLECTING THE DIAPHRAGM LOADINGS AND LOAD PATH ALL THE WAY TO THE FOUNDATION PLEASE SEE THE FOLLOWING CORRECTIONS ALSO A) THE CALCULATIONS INDICATED WIND GOVERNS BUT THERE SEEMS NO SEISMIC ANALYSIS WERE SUBMITTED TO COMPARE WITH a) PLEASE SUBMIT CALCULATIONS FOR THE LATERAL LOADS TO VERIFY CRITICAL LOADINGS AS PRESCRIBED BY THE SECTION 1612 OF THE 97 UBC b) FOR ORDINARY MOMENT FRAME FOR STEEL THE R VALUE SHOULD BE 4 5 AND NOT 5 5 c) THE DETAIL 5/S-6 DOES NOT SEEM TO SHOW THE REQUIRED SHEAR WALL TO TRANSFER THE DIAPHRAGM LOAD TO THE MOMENT FRAME d) IT SEEMS THAT THE TRUSS CONNECTED TO THE MOMENT FRAME COULD BE A DRAG TRUSS PLEASE INDICATE ON THE FRAMING PLAN THE REQUIRED DRAG FORCE FOR THE SAME TRUSS el IT SEEMS THAT THE STRUCTURAL ELEMENTS OF THE MOMENT FRAME IS EXCEEDING THE REQUIRED UNITY PLEASE CLARIFY ft THE PAGES AFTER THE FAST FRAME ANALYSIS SEEM TO HAVE ANALYZED THE MOMENT FRAME AGAIN PLEASE CLARIFY Cartsbad PCR06-116 (Orig O5-2O57) September 21, 2O06 al PLEASE SUBMIT CALCULATIONS FOR THE CONNECTIONS OF THE MOMENT FRAME TO VERIFY COMPLIANCE WITH THE SECTION 2213 6 OF THE 97 UBC hi ALONG LINE 3 25 REFLECTED ON THE ROOF FRAMING PLAN (S3 1) SHOWS DRAG TRUSS CONNECTED TO THE STEEL TUBE BUT THE SAME TUBE DOES NOT SEEM TO CARRY ANY LATERAL LOAD il AGAIN. PLEASE SUBMIT COMPLETE LATERAL ANALYSIS PLEASE DO NOT JUST ANALYZE THE MOMENT FRAMES BUT ALSO THE SHEAR WALLS TO VERIFY STABILITY OF THE WHOLE HOUSE il IT LOOKS LIKE THAT THE ORIGINAL COMMENT # 3 IS STILL NOT RESPONDED TO k) IT SEEMS THAT THERE IS NO CALCULATIONS MADE FOR THE MOMENT FRAME ALONG LINE 2 75 TO INCLUDE THE GRADE BEAM H IT SEEMS THAT ANCHOR BOLTS CALCULATIONS RECOMMENDED 24" EMBEDMENT INTO THE CONCRETE BUT NOT SHOWN ON THE PLANS PLEASE SUBMIT COMPLETE ANALYSIS TO VERIFY CONFORMANCE TO SECTION 1923 OF THE 97 UBC ml A COMPLETE STRUCTURAL PLAN CHECK WHEN ALL THE ITEMS ABOVE ARE MET On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below Section 106 3 2 IT SEEMS NOT RESPONDED TO • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED-? REMARKS FIELD WELDING SPECIAL MOMENT FRAME CONNECTIONS (SEISMIC ZONES 3 & 4 ONLY) CONCRETE HIGH-STRENGTH BOLTS EXPANSION/EPOXY ANCHORS When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached form IT SEEMS THAT THE FORM DID NOT INCLUDE THE CONCRETE AND THE HS BOLTS Carlsbad PCR06-116 (Orig.05-2057) September 21, 2006 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation Thank you EsGil Corporation In (Partnership with government for (BuMing Safety DATE September 6, 2006 O I APPLICANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO PCR06-116 (Orig.O5-2057) SET IV PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Revisions for Baum Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Ray Baum 1014 Tulip Way, Carlsbad, CA 92011 I | Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Ray Baum. Telephone # 760-931-6797 Date contacted ^[b t^^k^A) Fax # 760-722-3148 Mail Telephone Faxv' In Person REMARKS By Steve Sanders for Bert Domingo Enclosures Esgil Corporation D GA D MB D EJ D PC 8/28/06 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego. California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad PCRO6-116 (Orig O5-2057) September 6, 2OO6 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO PCRO6-116 (Ong.O5-2O57) PROJECT ADDRESS 1014 Tulip Way SET IV DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 8/28/06 September 6, 2006 REVIEWED BY Steve Sanders for Bert Domingo FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to Esgil Corp ortothebldg dept of the juris B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes aNo Carlsbad PCR06-116 (Orig.O5-2057) September 6, 2006 o PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments 2 Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation Specify expiration date of license (California Business and Professions Code) 3 Please detail the shear transfer from the roof diaphragm at the stairs to the new moment frame 4 Please provide a plan view of detail 4/S-7 Please show how a full penetration groove weld will be provided for the 1/2" x 8" x 12" A36 plate 5 On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below Section 106 3 2 • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED'? REMARKS FIELD WELDING SPECIAL MOMENT FRAME CONNECTIONS (SEISMIC ZONES 3 & 4 ONLY) HIGH-STRENGTH BOLTS EXPANSION/EPOXY ANCHORS 6 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached form Carlsbad PCR06-116 (Orig.O5-2O57) September 6, 2006 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans • Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Steve Sanders for Bert Domingo at Esgil Corporation Thank you Carlsbad PCRO6-116 (Ong.O5-2O57) September 6, 2OO6 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No PCR06-116 (Orig.O5-2057) Job Address or Legal Description 1014 Tulip Way Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet (over) Carlsbad PCRO6-116 (Orig.O5-2O57) September 6, 2O06 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION //}/*-/ PLAN CHECK NUMBER tlSS) !/-- OWNER'S NAME I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 Signed _ I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above Engineer's/Architect's Seal ialuWttore Signed 1 List of work requiring special inspection n Soils Compliance Prior to Foundation Inspection (J3 Field Welding D Structural Concrete Over 2500 PSI R/High Strength Bolting O Prestressed Concrete |Y] Expansion/Epoxy Anchors D Structural Masonry G Sprayed-On Fireproofmg CD Designer Specified [~| Other 2 Name(s) of mdividual(s) or firm(s) responsible for the special inspections listed above A B C 3 Duties of the special inspectors for the work listed above A B C Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site Carlsbad PCR06-116 (Orig O5-2057) September 6, 20O6 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No PCRO6-116 (Orig.05-2057) Job Address or Legal Description 1014 Tulip Way Owner tfj V ft/tiThl _ Address /O/tJ yt/£//* /U# V . You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate matenals, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet " (over) Carlsbad PCRO6-116 (Ong.05-2O57) November 3O, 20O6 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION AW ~H>\& PLAN CHECK NUMBER & &&06^h OWNER'S NAME KJW I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above Engineer's/Art^ - - - • & Signatyi Signed 1 List of work requiring special inspection [0^oils Compliance Prior to Foundation Inspection Q'Tield Welding ^^O/^CAX^x' [^'Structural Concrete Over 2500 PSI O Wigh Strength Boltmg*:^=:r^*'^ G Prestressed Concrete Qcxpansion/Epoxy Anchors G Structural Masonry G Sprayed-On Fireproofmg G Designer Specified G Other 2 Name(s) of mdividual(s) or firm(s) responsible for the special inspections listed above A B C 3 Duties of the special inspectors for the work listed above A B Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site EsGil Corporation In Partnership with government for <BuMing Safety DATE August 21, 2O06 JURISDICTION Carlsbad a FILE PLAN CHECK NO PCRO6-116 (Orig 05-2057) SET III PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Revisions for Baum Residence Addition and Remodel I | The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck 2Sl The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person IXI The applicant's copy of the check list has been sent to Ray Baum 1014 Tulip Way, Carlsbad, CA 92011 I I Esgil Corporation staff did not advise the applicant that the plan check has been completed IXI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Ray Baum GJ M) Telephone* 760-931-6797 Date contacted <* IzzJo^ (by \^ ) Fax # (l (j> o) 12-2- 2>/ <-/ f Mail -^ Telephone -^ Fax ^ In Person REMARKS By Steve Sanders for Bert Domingo & Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC 8/11/06 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad PCRO6-116 (Orig 05-2057) August 21, 2O06 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO PCR06-116 (Orig 05-2057) PROJECT ADDRESS 1014 Tulip Way SET III DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 8/11/06 August 21, 2OO6 REVIEWED BY Steve Sanders for Bert Domingo & Bill Elizarraras FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to THE JURISDICTION'S BUILDING DEPARTMENT B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes aNo Carlsbad PCRO6-116 (Orig.05-2057) August 21, 2O06 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments 2 Plans, specifications and calculations shall be signed and sealed bv the California state licensed engineer or architect responsible for their preparation Specify expiration date of license (California Business and Professions Code) 3 Show how the shear load on the 2nd floor would be transferred thru the openings (above the living room and stairwell) to the resisting elements The response references details 7 & 9/S-6 showing straps to plates'? But did not show how the lateral loads will be transferred to the resisting elements Please submit complete analyses reflecting diaphragm loading and load path all the way to the foundation AGAIN. PLEASE SUBMIT COMPLETE ANALYSIS REFLECTING THE DIAPHRAGM LOADINGS AND LOAD PATH ALL THE WAY TO THE FOUNDATION PLEASE SEE THE FOLLOWING CORRECTIONS ALSO A) THE CALCULATIONS INDICATED WIND GOVERNS BUT THERE SEEMS NO SEISMIC ANALYSIS WERE SUBMITTED TO COMPARE WITH B) PLEASE SHOW HOW THE LOADS WERE DERIVED WHERE THE 2000 # CAME FROM. ETCETERA C) THE CALCULATIONS FOR LINE 2 INDICATES THAT THE COLUMNS WOULD TAKE THE LATERAL LOADS BUT SEEM NOT RESTRAINED TO CARRY THE OVERTURNING EFFECT OF THE LATERAL LOAD PLEASE THE OTHER COLUMNS ALSO D) THE CALCULATIONS SEEM TO HAVE USED THE X-X PROPERTY OF THE SECTION OF THE COLUMNS BUT THE PLANS SEEM TO SHOW DIFFERENTLY E) IN VIEW OF THE ABOVE. THE COLUMNS SEEM NOT COMPATIBLE WITH THE INTENT OF SUPPORTING THE LATERAL LOAD F) AGAIN. PLEASE SUBMIT COMPLETE LATERAL ANALYSIS PLEASE SEE ITEM 3 ABOVE Carlsbad PCR06-116 (Orig.05-2O57) August 21, 2006 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bert Domingo at Esgil Corporation Thank you EsGii Corporation In Partnership with government for <Bm[<fing Safety DATE July 31, 2005 OAEEUCANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO PCR06- 1 16 (Orig 05-2057) SET II PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Revisions for Baum Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Ray Baum 1014 Tulip Way, Carlsbad, CA 92011 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted ,Rav Baum Telephone # 760-931-6797 Date contacted ^/ f /#£(by/^) Fax #// Mail telephone A/ Fax In Person REMARKS By Bill Ehzarraras Enclosures Esgil Corporation D GA D MB D EJ D PC 7/20/06 tmsmUdot 9320 Chesapeake Drive, Suite 208 4* San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576 PCR06-116 (Orig.O5-2O57) July 31, 2OO5 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad (Ong.O5-2O57) PROJECT ADDRESS 1014 Tulip Way DATE PLAN RECEIVED BY ESGIL CORPORATION 7/20/06 REVIEWED BY Bill Ehzarraras PLAN CHECK NO PCR06-116 SET II DATE RECHECK COMPLETED July 31, 2005 FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to THE JURISDICTION'S BUILDING DEPARTMENT B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo Carlsbad PCRO6-116 (Orig 05-2057) Jfcly 31, 2005 • The following corrections are from the original deficiency list, and were either not addressed or a result of new changes • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments 2 Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation Specify expiration date of license (California Business and Professions Code) 3 Show how the shear load on the 2nd floor would be transferred thru the openings (above the living room and stairwell) to the resisting elements The response references details 7 & 9/S-6 showing straps to plates7 But did not show how the lateral loads will be transferred to the resisting elements Please submit complete analyses reflecting diaphragm loading and load path all the way to the foundation To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bert Domingo for Bill Ehzarraras at Esgil Corporation Thank you EsGil Corporation In (Partnership with government for <Bui[ding Safety DATE July 13, 2O05 a APPLICANT JURISDICTION Carlsbad /a PLAN REVIEWER a FILE PLAN CHECK NO PCRO6-116 (Orig 05-2O57) SET I PROJECT ADDRESS 1014 Tulip Way PROJECT NAME Revisions for Baum Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Ray Baum 1014 Tulip Way, Carlsbad, CA 92011 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed /• , \Person contacted Ray Baum (J/t^J Telephone # 760-931-6797 /^^ (by ]^} Fax #J^ x •* r" ' MaiL-^Telephone -^ Fax In Person REMARKS By Bill Ehzarraras Enclosures Esgil Corporation D GA D MB D EJ D PC 7/5/06 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 Carlsbad PCR06-116 (Orig 05-2057) July 13, 2005 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO PCR06-116 (Orig O5-2O57) JURISDICTION Carlsbad PROJECT ADDRESS 1014 Tulip Way FLOOR AREA STORIES REMARKS Revision DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED July 13, 2005 HEIGHT DATE PLANS RECEIVED BY ESGIL CORPORATION 7/5/06 PLAN REVIEWER Bill Ehzarraras FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes 1997 UBC, 2000 UPC, 2000 UMC and 2002 NEC The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e . plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans Carlsbad PCRO6-116 (Orig 05-2O57) July 13, 2005 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments 2 Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation Specify expiration date of license (California Business and Professions Code) 3 When severing original Architect from project and revising plans, none of the new revised designs may bear the Architects name or stamp Please remove or replace sheets 4 Several of the windows from the two different floor plans are contradicting? Some need to be tempered on the new design 5 Glazing in the following locations should be of safety glazing material in accordance with Section 2406 4 for new designs a) Where the bottom exposed edge of the window glazing is less than 60 inches above a standing surface and dram inlet of tubs and drains b) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface c) Walls enclosing stairway landings or within 5 feet of the bottom and top of stairways where the bottom edge of the glass is less than 60 inches above a walking surface 6 Show the placement and configuration of the new bathroom layouts 7 Please show calculations for the connection of the moment frame to verify conformance to section 2213 6 UBC 8 Show how the shear load on the 2nd floor would be transferred thru the openings (above the living room and stairwell) to the resisting elements Carlsbad PCR06-116 (Orig O5-2O57) July 13, 2005 9 If you are using the pre-fab moment frames from Hardy, please provide the Hardy details on the plans To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation Thank you Carlsbad PCR06-116 (Orig 05-2057) July 13, 2005 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO PCR06-116 (Orig 05-2057) PREPARED BY Bill Ehzarraras DATE July 13, 2005 BUILDING ADDRESS 1014 Tulip Way BUILDING OCCUPANCY R3/U1 TYPE OF CONSTRUCTION VN BUILDING PORTION Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) cb RIHn Pprrml- FPP hv Orrlinanrp ^ 1 Valuation Multiplier By Ordinance Reg Mod VALUE ($) > •* | Plan Check Fee by Ordinance '"* \ Type of Review n Complete Review $360 00 F Structural Only I~ Repetitive Fee Repeats l~ Other ,-T Hourly Hours * r <r * Based on hourly rate Comments Esgil Plan Review Fee r $288 00 Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER ADDRESS fot¥^ DATE RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR (<$10,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER )C PLANNER ENGINEE DATE DATE Docs/MiatomB/Planning Engineering Approvals Cfl o o odecn a aa. fS. S.nn efb n Plan Check No Planner Chris Sexton PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Address Phone (760) 602-4624 Type of Project & Use Zoning ft* J General Plan CFD (in/out) #_Date of participation Net Project Density.DU/AC Facilities Management Zone Remaining net dev acres. Circle One (For non-residential development Type of land used created by this permit ) Legend C3 Item Complete D Item Incomplete - Needs your action Environmental Review Required YES NO j^/TYPE DATE OF COMPLETION Compliance with conditions of approval? If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/RESO NO PROJECT NO YES NO \^ TYPE. DATE OTHER RELATED CASES Compliance with conditions or approval? If not, state conditions which require action Conditions of Approval D D D Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO CA Coastal Commission Authority? YES NO If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619)767-2370 Determine status (Coastal Permit Required or Exempt) D Habitat Management Plan Data Entry Completed? YES NO w^ If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE') £jj CU Inclusionary Housing Fee required YES _ NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Completed? YES _ NO _ (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Site Plan ODD Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal description of property and assessor's parcel number nnn Policy 44 - Neighborhood Architectural Design Guidelines 1 Applicability YES NO. 2 Project complies YES NO_ Zoning 1 Setbacks Front Side ide Rear Top of slope Required Required Required Required Required 2 Accessory structure setbacks Front Required Interior Side Required Street Side Required Rear Required Structure separation Required 3 Lot Coverage Required. 4 Height Required' I , ^ v/r" Shown Shown Shown Shown Shown Spaces Required Shown Shown . Shown . Shown . Shown Shown. Shown. Shown5 Parking (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comm OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 >*• Servin Engineering, Inc. 2382 Camino Vida Roble, Suite F Carlsbad, CA 92011 (760)931-1792, Fax (760)931-1892 Email nservin(fljservin-engineenng com November 20, 2006 Esgil Corporation 9230 Chesapeake Drive, Suite 208 San Diego, California 92123 858-560-1468, 858-560-1576 Fax Attention Chuck Mendenhal Regarding PCF06-116 (Original 05-2057) 1014 Tulip for Ray Baum, Remodel and addition Dear Chuck It pains me to write this letter I feel 1 have no choice in the matter, therefore my action Your company has always been a pillar of fair review on behalf of the agencies, which is why its taken me a while to come to this point On November 17, 2006 we went to your offices to meet with Bert Domingo on this project, to discuss the lengthy plan check since July 13, 2005 up to now History A permit was granted on this proj ect in 2005 Unfortunately, the previous designer had overlooked some site encroachments which required a slight re-design of the home, but essentially, the home remained the same The client hired another architect to assert the true dimensions of the site and house on said lot Consequently, we had to revise some of our engineering Subsequent to this, a submital for revision was made for the changes Initially, Bill Elizarraras did the review with only 3 structural comments relating to a certain portion of the building on July 13, 2005 We addressed the correction with a specific response and we got 1 structural comment on July 31,2005 Then in August 21,2006, we got a response from Steve Sanders on behalf of Bill and Bert This time we received multiple comments related to the same question from Bill At that point my office offered to meet with Bert He said to resubmit with responses to the comments On September 6,2006 we received comments back to our responses with a toned down version of comment #3 to specifics relating to shear transfer details only, and one other comment, #4 At this point we felt that we finally got through and were on our way to getting a plan change We were surprised that on September 21 the old comments to question #3 had resurrected At this point we were very confused, to say the least Again, we offered to meet, but were told to submit the plans again with corrections On October 6, 2006 we again receive comments from Bert this time, expanding on the original correction with some specifics, which were appreciated He concludes with saying that, "Again the lateral system of the building has been changing so many times " We have not changed as he states other that to offer remedies to the comments he had previously Again, we offer to meet only to have him arrogantly excuse my engineering assistant to resubmit only, which we did Again on October 31,2006, from the comments received in bold, caps and double underlined one can sense the frustration on his part This time he offers to meet, which we finally did on November 17 Meeting and discussion In our meeting on the 17"1, Bert was cordial, as always He asked, did you make revisions to address my comments91 said, we came here for two purposes, first, we need to know where the confusion lies between you and us due to our apparent lack of understanding your comments entirely or you not understanding our responses to your comments, second, I'd like to explain our design schematic for this project I started to explain the lateral and vertical loading from top to bottom, especially in the area of real concern over the winding stair were we have some columns that transfer the loading to the diaphragms below He stopped me on several occasions to explain that we needed to explain the entire building's lateral system because it had never been resolved I argued that it did not make sense, since we already had a building permit and that we were in to make a plan change only He argued that the previous permit was only for the stair, I said no it was not and I stated if that was the case, then why did the previous plan checkers only discuss the stair area diaphragm loading only I appeared to have gotten under his skin somehow, due to his apparent change in tone and demeanor and condescending remarks After some point, I again asked him to let me continue with the explanation on the entire building, which I did Finally, he acknowledged that it appeared that we had shear walls throughout all directions to handle the loads It appeared that the only contention was the upper roof diaphragm/column system remained to be the issue, that he would look at when we resubmitted In conclusion with our meeting, he offered to review the entire calculations along with the updated plans I indicated that we would submit next week and thanked him for his time and shook hands Concern Chuck, I'm not one to skirt around the issues or engineering concerns, which is why I like the consistency of EsgiPs approach to being consistent with reviews, unlike some small cities I'm concerned that Bert holds resentment toward me somehow and is taking it out on my project and client During our meeting, he did get animated and raised his voice then he condescendingly addressed me as "Nick, you are an engineer, you should know better, you know how to do this The miscommumcation is on your part, not mine " I do have a witness to this unprofessional conduct But more importantly, Bert has a duty to your company as a representative to resolve issues/conflicts in the most efficient manner and move on to the next proj ect, as wel 1 as a duty to the City of Carlsbad Case in point, in the past dealing with Manuel Ainza, formerly with Esgil and now with the County of San Diego, we resolved issues with a face to face meeting where we hashed it out on the spot and sign off, as you have in the past with me Ainza is a registered SE as you are, I hold both of you in high esteem and grateful to know you both I'm not sure what I ever did to Bert to deserve this He is a sharp engineer and I do respect him, but he should not resort to unprofessional behavior, as he did on Friday When Bert was a private engineer, I helped him on a Flood Analysis using HEC2, he was grateful then My assistant was shocked at his behavior Sorry about being so long with the letter, I will conclude now I wish to have the review performed by either you or Sergio Azuela Sergio has been a fair reviewer in the past and similar to Ainza, we have had face to face meetings and we have resolved the issues on the spot One last note of concern, my client is in severe financial distress due to the hold up since July He may loose his house because the bank won't release any more money until he has more inspections Don't take my word for it, you may call him at 760-931-6797 or fax him at 760-722-3148 Chuck, I thank you for all of your help on this matter, you have always been one to provide assistance and a fair review Sincerely yours, NICK SERVIN, PE, Principal Engineer #33538 \\Servineng\data\john\D\Jobs\Tulip\Esgil 1 wpd \0 itf i O