HomeMy WebLinkAbout1014 TULIP WAY; ; CB900507; Permit03-09-2009
Job Address
Permit Type
Parcel No
Valuation
OccGroup
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Building Permit Permit No:CB900507
Building Inspection Request Line (760) 602-2725
1014 TULIP WY CHAD
RAD Sub Type
2144101200 Lot #
$0 00 Const Type VN
Reference #
Project Title LEGALIZE EXISTING ADDITION
SFD LOT 236 CT 8453
Status
Applied
Entered By
Appr/Issued
Inspect Area
EXPIRED
03/27/1990
CD
PD
Applicant
BAUM, RAY
Owner
BAUM KATHERINE
1014 TULIP WY
CARLSBD, CA 92009
9316797
Total Fees
$0 00
$76 00 Payments To Date $76 00 Balance Due
Description
Other
Fee
76 00
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition' of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these feesfexactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
"PERMIT APPLICATION
City of Carlsbad Building Department
2075 Las Palmas Dr , Carlsbad, CA 92009 (619) 438-1101
L PERMIT TYPE
~A rj COMMERCIAL ^NEWFjTENANT IMPROVEMENT
B n INDUSTRIAL QNEW QTENANT IMPROVEMENT
c ^RESIDENTIAL DEPARTMENT DCONC)0 J2SINGLE FAMILY DWELLING ^ADDITION/ALTERATION
DDUPLEX QDEMOLITION QRELOCATION QMOBILE HOME ^ELECTRICAL QPLUMBING
fjMECHANICAL DpuOL DSPA DRETAININ(; UALL DSOLARXG OTHER_
PROJECT INFORMATION PLAN CHECK No
Building or Suite No/T FOR OFFICE USE ONLY
Address
Nearest Cross Streets
LEGAL DESCRIPTION
CHECK BELOW IF SUBMITTED
D2 Energy Calcs
ASSESSOR'S PARCEL \
Lot No Subdivision
C]2 Structural Calcsguy- wo -12
Name/Number „
D2 Soils Report D 1 Addressed
EXISTING USE
Unit No
Envelope
(
Phase No
PROPOSED USE
DESCRIPTION OF WORK ^. v . •
BLDG SQ FTG OF STORIES
3.
4
5
6
7
CONTACT PERSON
NAME nft~Y oAtxM
CITY C.A-fc'£>^*^) STATE <
SIGNATURE
APPLICANT D CONTRACTOR D AGENT
NAME
<iJL^i j^CITY ^-^nr1-*— STATE
PROPERTY OWNER OWNER
NAME -,
CITY ^ STATE
CONTRACTORNAME
CITY \__^^CX_) >>^_y f^Z \ — *» STATE
STATE LIC #
SIGNATURE
DESIGNER NAME
CITC STATE
WORKERS' COMPENSATION
Workers' Compensation Dec 1 arat ion I hereby aff i rm that
/A/ t/ TU!ADDRESS "•" '
(H ZIP CODE ^OJ9<S 1
FOR CONTRACTOR QOWNER
ADDRESS
HP CODE
ADDRESS
ZIP CODE
ADDRESS
ZIP CODE
LICENSE CLASS
TITLE
ADDRESS
ZIP CODE
I have a certificate of consent to
an admitted insurer or an exact
DAY TELEPHONE (fa t \) ^Ql ~ &> 11 TT
•
D AGENT FOR OWNER
DAY TELEPHONE
DLESSEE DTENANT
DAY TELEPHONE
DAY TELEPHONE
CITY BUSINESS LIC #
DATE
DAY TELEPHONE STATE LIC #
self insure issued by the Director of Industrial Relations,
copy or duplicate thereof certified by the Director of the
insurer thereof filed with the Building Inspection Department {Section 3800 Lab C)
INSURANCE COMPANY EXPIRATION DATE
Certificate of Exemption I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner
so as to become subject to the Workers' Compensation Laws of California
SIGNATURE
8 OWNER-BUILDER DECLARATION
Owner Builder Declaration I hereby affirm that I am exempt from the Contractor's License Law for the following reason
I as owner of the property or my employees with wages ns, their sole compensation, will do the work and the structure is not intended or offered for ^ale
(Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and who
does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however the building
or improvement is sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose
of sale )
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code
The Contractor's License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s)
licensed pursuant to the Contractor's License Law)
I am exempt under Section Business and Professions Code for this reason
COMPLETE THIS SECTION FOR NONRESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act'
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district'
DYES DNO
Is the facility to be constructed within 1 000 feet of the outer boundary of a school site'
DYES DNO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS
OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT _
i CONSTRUCTION LENDING AGENCY _
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097( i ) Civil Code)
LENDER'S NAME LENDER'S ADDRESS
10 APPLICANT'S SIGNATURE
I certify that I have read the application and state that the above information is correct I agree to comply with all City ordinances and State laws relating
to building construction I hereby authorize representative:, of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO
AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINSI ALL LIABILITIES JUDGMENTS COSIS AND EXPENSES WHICH MAY IN ANY UAY ACCRUE AGAINST SAID
CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
Expiration Every permit issued by the Building Official under the provisions of this Code shall expire by limitation .ind become null and void if the building
or work authorized by sucft permit is not commenced within 180 days from the date of such permit or if rhe building or work /luthonzcd by such permit is suspended
or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code)
APPLICANT'S SIGNATUI ] CONTRACTOR [~|BY PHONE APPROVED BY
DATE
WHITE File YELLOW Applicant PINK Finance
DATE: 03/07/91
TO: RAY BAUM
1014 TULIP WY
CARLSBD, CA 92009
PLAN CHECK EXPIRATION
PC# CB900507 DATE: 03/27/91
ADDRESS: 1014 TULIP WY
You have applied to have your plans checked on the date shown
above, and you have not obtained your building permit.
The provisions of Section 304(d) of the Uniform Building Code
state:
"Section 304(d) Expiration of Plan Review
Applications for which no permit is issued
within one year following the date of
application shall expire by limitation, and
plans and other data submitted for review
may thereafter be returned to the applicant
or destroyed by the Building Official.
In order to renew action on an application
after expiration, the applicant shall resubmit
plans and pay a new plan review fee."
Please check the appropriate box indicating your choice
and return this letter to the BUILDING DEPARTMENT.
PROJECT ABANDONED. I WILL PICK UP PLANS WITHIN 10 DAYS.
PROJECT ABANDONED. PLANS MAY BE DESTROYED.
If you have any questions, please contact the Building
Department at (619) 438-1161.
DORIS COSMAN
Building Department
Ray Gamson
Building Department
Mr Garrison,
Along with the order to remove the addition, on our residence, was a copy of
the letter sent February 19,1991 by Carter Darnell, reguarding plancheck 90-507 In
his letter Mr Darnell stated, "It is our desiie to solve code violations in the simplest
way, but we must coclude that you no longer wish to legalize this violation "
Well that is not the case at all, we defmately want to conect this situation Had I
received the letter from Mr Darnell I would have contacted him at that time, but my
Mother (Kathenne Baum) did not forward it to me My mother is retired, living in
the house, while my primary residence is in Simi, Ca
We puchased the house from a local licensed contractor, although we were told
that there were no building permits we were appalled at the number and seventy of
code violations When the list of corrections came back I instructed and paid the
architect, who drew the plans, to precede with the necessary collections They wei e
supposed to be finished in three to tour months He had some setbacks, but I must
take responsibility for not persuing the project from September on due to the tact
that 1 have been unemployed trying to start my own company Since the first ot the
year the architect has failed to complete his obligation even undei the thieat of legal
action Since February I have tried to get the architect to return all the paper work to
another engineer to hopefuly finish, so we can continue
I know this letter may be too little too late, but we really would like to correct
the violations Unfortunately, with my mother on a fixed income and the large debt
] have incurred since October, it will be financially as well as physically impossable
tor us to remove the addition by the deadline imposed 1 imagine it is to late to alter
the proceedings, but if at all possible, I would like to puisue the completion of the
project since I have already paid a good deal of money to solve the problems
My apologies for the lengthy explanation, but I wanted you to know we leally
want to finish the pi oject I know your hands may be tied, but any assistance would
be giatefully appreciated Thank you for all that you folks at the building
department have done, if there is any hope or alternative please contact me
Respectfully yours,
•Q Q^lV^ Pc"-""^
Ray Baum
c Pat Kelley, Senoir Building Inspector
February 19, 1991
Ray Baum
1014 Tulip
Carlsbad, Ca 92009
PLANCHECK 90-507 LEGALIZE EXISTING ADDITION
You applied for this plancheck on March 27, 1990. It will expire on
the same date this year, approximately one month from now.
You have corrections from three departments which were sent to you
between March 29 and April 6 of last year. Since then we have heard
nothing from you.
It is our desire to solve code violations in the simplest way, but we
must conclude that you no longer wish to legalize this violation, and
after reading the correction lists, we realize it may not be possible
to do so. Your alternative is to remove the addition. Please call
for an inspection when you have done this.
of this letter I am informing the Enforcement Officer of your
lap-tf of action. If the plan check expires March 27, 1991, I assume
will take whatever legal action is necessary.
£TER DARNELL, PLAffCllECK COORDINATOR
c: Ray Garrison, Enforcement
Pat Kelley, Senior Building Inspector
2O75 Las Palrnas Drive » Carlsbad California 92OO9-4359- (6 I 9) -138-1 161
ESGIL, CORPORATION
9320 CHESAPEAKE DR., SUITE 2O8
SAN DIEGO, CA 92123
(619) 56O-1468
( /DATE: ~£Xi ( 1 APPLICANT
JURISDICTION: /,n#_£ ["PLAN CHECKER
COPY
PLAN CHECK NO: YU'&O*/ SET: __[_ f~ UPS
^ '"DESIGNER
PROJECT ADDRESS: ^ '
s
PROJECT NAME: ,/IM.
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
I—- The applicant's copy of the check list is enclosed for the
•—' jurisdiction to return to the applicant contact person.
I The applicant's copy of the check list has been sent to:
ij Esgil staff did not advise the applicant contact person that
L plan check has been completed.
Ij Esgil staff did advise applicant that the plan check has
— been completed. Person contacted:
Date contacted: _ Telephone £
REMARKS; 'Pfe/K r^ttS/Tld /~C> Q &
^•^JfMJOJL^ fry //- Enclosures:
ESGIL CORPORATION
_HGA 'JjAA L]RN HDM
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE:
JURISDICTION:
PLAN CHECK NO:
CARLSBAD
SET:
PROJECT ADDRESS:
PROJECT NAME:I T? r; •;
CHECKER
COPY
QUPS
HDESIGNER
D
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's-building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and snould be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
I The applicant's copy of the check list has been sent to:
jj^j Esgil staff did not advise the applicant contact person that
^^ plan check has been completed.
{] Esgil staff did advise applicant that the plan check has
— been completed. Person contacted:
Date contacted:
REMARKS:
Telephone #
By: f /==,
ESGIL CORPORATION
DGA DAA Dvw QDM
Enclosures:
TLAN CHECK NO:70-5-07 FOREWORD; PLEASE READ
JURISDICTION: CITY OF CARLSBAD
TO:Y 6 A u/
ENCLOSURES:
PROJECT ADDRESS:
FLOOR AREA: / 3
STORIES: /
HEIGHT:0/C
REMARKS:
PLAN COKRKUXiOS
CIT? OF CARLSBAD
SINGLE FAMILY AND DUPLEX DWELLINGS
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the
handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections based
on laws and ordinances by the Planning Department,
Engineering Department or other departments.
Present California law mandates that residential
construction comply with Title 24 and the following
model codes:
1988 UBC (eff. 1/1790)
1988 UPC (eff. 1/1/90)
1987 NEC (eff. 10/28/87)
1988 UMC (eff. 1/1/90)
The above regulations
construction, regardless
adopted by ordinance.
apply to residential
of the code editions
The circled items listed need clarification,
modification or change. All items have to be
satisfied before the plans will be in conformance
with the cited codes and regulations. Per Sec
303(c), 1988 Uniform Building Code, the approval of
the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, note on this list
(or a copy) where each correction item has been
addressed i.e.. plan sheet, specification, etc. Be
sure to e"i:lose the marVed .>t> lirt vhen VQJ sjbrit
the revised plans.
Date plans received by jurisdiction:
Date plans received by Esgil Corporation:
Date initial plan check completed:
Bv; ?
Applicant contact person:
Telephone:.
NOTE: FAGS NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED.
List No. 12, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1988 UBC)
PLANS
Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, California 92123,
(619) 560-1468.
Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have been
returned to you by the jurisdiction, to:
The jurisdiction's building department.
Indicate on the Title Sheet of the plans, the
name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302(a)7.
All sheets of plans must be signed by the
person responsible for their preparation
(California Business and Professions Code).
Plans, specifications and calculations shall be
signed by the California state licensed
engineer or architect responsible for their
preparation, for plans deviating from
conventional wood frame construction Specify
expiration date of license (California
Business and Professions Code).
Specify on the Title Sheet of the plans the
gross floor area of each element of this
project including dwelling, garage, carport,
patio, deck and balcony. Section 302(d)
Provide a statement on the Title Sheet of the
plans that this project shall comply with Title
24 and 1988 UBC, UMC and UPC and 1987 NEC.
Submit fully dimensioned plot plan drawn to
scale showing location, size, and use of all
existing and proposed structures on the lot
Identify property lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes Show finish floor elevations and
show elevations of adjacent finish grade
Show drainage patterns with minimum slopes
Section 302(d).
Indicate distance from property lines to
proposed building. Section 302(d).
Show on the title sheet all structures, pools,
vails, etc. included under this application
Any portion of the project shown on the site
plan that is not included with the building
permit application filed should be clearly
identified as "not included."
Clearly show if the lower level is a basement
or a story, based on the definitions in
Sections 403 and 420. Plot the finish grade
(as defined) on the elevations and dimension
the distance to the floor above, for story
determination
On the cover sheet of the plans, specify any
items requiring special inspection, by way of
the following-
REQUIRED SPECIAL INSTRUCTIONS
In addition to the regular inspections, the
following checked items will also require
Special Inspection in accordance with Sec 306
of the Uniform Building Code.
ITEM REQ IF
CHECKED
REMARKS
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP
STPUCTURAL CONCRETE
OVER 2500 PSI
PRESTRESSED STEEL
FIELD WELDING
HIGH STRENGTH BOLTS
EXPANSION ANCHORS
SPECIAL MASONRY
SPRAYED ON FIRE
PROOFING
PILES/CAISSONS
DESIGNER-SPECIFIED
OTHER
FTP:-: PPOTECTIOK
Exterior walls closer than 3 feet to property
lines shall be one-hour rated construction and
have no openings. Table 5-A.
12/11/89
Exterior walls closer than 3 feet to a property
line shall have 30 inch parapets when the floor
area per floor exceeds 1,000 square feet.
Section 1709.
Projections, including eaves, may not extend
more than 12 inches into the 3 foot setback
from the property line. Section 1710.
Eaves over required windows shall be not less
than 30 inches from the side and rear property
lines. Section 504.
Plastic skylights shall not be installed within
that portion of a roof located within a
distance to property line where openings in
exterior walls are prohibited or required to be
protected. Section 5207 (a) 7.
Projections, including eaves, shall be one-
hour fire-resistive construction, heavy timber
or of noncombustible material if they project
into the 3' setback area from the property
line. Section 1710.
Show location of permanently wired smoke
detector:
a. Centrally located in corridor or area
giving access to sleeping rooms.
b. On each story
d. When sleeping rooms are upstairs, at the
upper level in close proximity to the
stair.
e. In rooms adjacent to hallways serving
bedrooms, when such rooms have a ceiling
height 24 inches or more above the ceiling
height in the hallway.
NOTE: Detectors shall sound an alarm audible in
all sleeping areas of the unit. Section 1210
2Q/ When the valuation of a room addition or repair
exceeds $1,000, or when sleeping rooms are
created, smoke detectors shall be provided at
existing bedrooms per item 19 above. Section
1210.
GEHERAL RESIDESHAL KHXJlKtMJOfrS
Habitable rooms, other than kitchens, shall
contain at least 70 square feet of floor area.
At least one room shall have not less than 120
square feet of floor area. Section 1207 (b)./•Window area must be at least 1/10 of the floor
area and a minimum of 10 square feet per
Section 1205 (a). Appears to be deficient in
Openable window area in habitable rooms must
be 1/20 of the floor area and a minimum of 5
square feet. In bathrooms, laundry rooms and
similar rooms 1/20 of area is required and
minimum is 1.5 sq. ft. Section 1205 (a).
At least 1/2 of the common wall must be open
and have an opening not less than 25 sq. ft.
nor one tenth of the floor area of the
interior room if light and ventilation is
being supplied from an adjacent room. Section
1205 (a).
Required windows shall not open into a roofed
porch unless the ceiling height is at least 7
feet, the longer side is at least 65% open,
and the porch abuts a street, yard or court.
Section 1205 (a).
Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, water closet compartments, laundry
rooms and similar rooms if required openable
windows are not provided. Section 1205 (c).
Show discharge point for exhaust air to be at
least 5 feet from any mechanical ventilating
intake. Section 1205(c).
Ductless fans cannot be used in bathrooms if a
tub or shower is present Section 1205(c).
No habitable room, other than a kitchen, shall
be less than 7'0" in any dimension. Section
1207 (c).
3J2C. Show that ceiling height for habitable rooms
is a minimum of 7'6". Section 1207 (a).
Show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a
minimum of 7'0" Section 1207 (a)
Dimension on the plans the 30" clear width for
water closet compartments and 24" clearance in
front of v-ater closet. Section 511 (a).
Specify safety glazing for glazing in
hazardous locations such as glass doors,
glazing adjacent to doors and glazing adjacent
to walking surfaces. Section 5406.
Glazing, in the sane wall rlane as a t'oor,
cue- oe safe.y glaz.r.g _£ «ithin 12" of the
door and less than 60" above the walking
surface, unless the glazing is leaded or
faceted glass. Section 5406 (d) 6.
Glazing in shower and tub enclosures shall be
tempered, laminated or approved plastic
(including windows within 5 feet of tub or
shower floor). Section 5406 (d) 5.
X
2/12/90
92
93
,
/
If required, show size, imbedment and location
of hold down anchors on foundation plan.
Section 302 (d).
If hold downs are required, note on plan that
hold down anchors must be tied in place prior
to foundation inspection. Section 305 (e) 1.
Show adequate footings under all bearing walls
and shear walls. Section 2907 (b).
Show on the plans stepped footings for slopes
steeper than 1:10. Section 2907 (c).
Show minimum 18" clearance from grade to bottom
of floor joists and minimum 12" clearance to
bottom of girders. Section 2516 (c) 2.
Show pier size, spacing and depth into
undisturbed soil. Table 29-A.
Show minimum underfloor access
Section 2516 (c).
of 18" x 24"
Show minimum underfloor ventilation equal to 1
sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners as
practicable and shall provide cross ventilation
on at least two approximately opposite sides.
Section 2516 (c) 6
FKAKIU6
WOj Show wall bracing. Every exterior wood stud
wall and main cross-stud partition shall be
braced at each end at least every 25 feet of
length with 1x4 diagonal let-in braces or
equivalent. Section 2517 (g) 3, Table 25-V.
In 2-story buildings, shear panels at the first
story (at least 48 inches in width) shall be
located at each end or as near thereto as
possible and comprise at least 25 percent of
the linear length of the wall, or provide
design Section 2517(g)3, Table 25-V.
Note cross bridging or blocking. Floor joists
and rafters 12" or more in depth shall be
supported laterally by bridging at intervals
not exceeding 8 feet, unless both edges are
held inline. Sec. 2506 (h), 2517 (d) 6.
!(&
10/.
Show blocking at ends and at
joists, rafters and trusses
Section 2517 (d) 3, 2517 (h)
s-jpports of floor
at exterior vails.
6.
Bearing partitions, perpendicular to joists,
shall not be offset from supporting girders,
beams, walls or partitions, more than the depth
of the joist. Section 2517 (d) 5.
10?<
/
Show rafter ties. Rafter ties shall be spaced
not more than 4 feet on center and be just
above the ceiling joists, where rafters and
ceiling joists are not parallel.
(h)
Section 2517
. Show rafter purlin braces to be not less than
45 degrees to the horizontal.
Section 2517 (h) 5.
'07. Show double top plate with minimum 48" lap
splice. Section 2517 (g) 2.
108. Show nailing will be in compliance with Table
I 25-0.25-Q.
'9. Show or note fire stops at
locations per Section 2516 (f):
the following
a. In concealed spaces of stud walls and
partitions, including furred spaces, at
the ceiling and floor levels and at 10
foot intervals along the length of the
wall,
b At all interconnections between concealed
vertical and horizontal spaces such as
occur at soffits, drop ceilings and cove
ceilings;
c. In concealed spaces between stair
stringers at the top and bottom of the
run and between studs along and inline
with the run of stairs if the \.alls under
the stairs are unfinished; and
d. In openings around vents, pipes, ducts,
chimneys, fireplaces and similar openings
which afford a passage for fire at
ceiling and floor levels, with
noncombustible materials.
In duplexes, draft stops shall be provided in
assemblies and attics in line
units and separating
floor-ceiling
with walls separating
units from common areas
1. Show stud size and spacing. Maximum allowable
stud heights: Bearing wall: 2 x4 and 2x6
max. 10'; Non-bearing: 2x4 max. 14', 2x6
max. 20'. Table 25-R-3.
floors, a roof and
or 2 x 6 at 16" o c.
Studs supporting tvo
ceiling must be 3 x 4
Table 25-R-3.
Note on A.I.T.C. Certificate of Compliance for
glued laminated wood members shall be given to
the building inspector prior to installation.
Section 2505.
2/12/90
Detail all post-to-beam and post-to-footing
connections and reference the detail to the
plan. Section 2516 (m).
ILg'. Detail shear transfer connections, including
/ roof and floor diaphragms, to shear walls.
' Section 2513.
116. Specify nail size and spacing for all shear
/ walls, floor and roof diaphragms. Indicate
required blocking,
dimension ratios.
Section 4714 (d)].
Maintain maximum diaphragm
[Tables 25 I, J, K and
?•
yx>
Provide truss details and truss calculations
for this project. Specify truss identification
numbers on the plans.
. Show 1/2" minimum clearance between top plate
of interior partitions and bottom chord of
trusses. (To ensure loading will be as
designed).
Provide roof framing plan and floor framing
plan. Section 302 (d).
. Provide framing sections through
Section 302 (d)
124. Specify all header sizes for opening over 4'
/ wide. Section 2517 (g) 5
Provide calculations for main vertical and
horizontal framing members and post footings.
Section 302 (b)
123^ Provide calculations for lateral loads, shear
v—-^ panels, shear transfer and related Section
302 (b). fP A/07
In Seismic Zones 3 and 4, the allowable shear
wall values for drywall in Table 47-1 must be
reduced 50 percent when considering earthquake
loads. This does not apply to wind loads.
Footnote 1,
Show on the plans all structural requirements
developed in the structural calculations.
Section 302 (d). (See cozmai.^s below or at
end.)
Columns and posts located on concrete or
masonry floors or decks exposed to the weather
or to water splash or in basements and which
support permanent structures shall be
supported by concrete piers or metal pedestals
projecting above floors unless approved wood
of natural resistance to decay or treated wood
is used. Section 2516 (c) 4.
Individual concrete or masonry piers shall
project at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
decay or treated wood is used.
Section 2516 (c) 4.
Show location of attic access
size 22" x 30". Section 3205.
with minimum
Show draft separation for attic areas between
units in a duplex. Section 2516 (f).
1^0.Specify plywood
thickness, grade
index. Table 25-S.
and/or particle board
and panel identification
127.
r-
When roof pitch
ridge as a beam.
is less than 3'12, design
Section 2517 (h).
If foundation cripple wall studs are less than
14" high, framing shall be solid blocking, or
sheathed with plywood. Section 2517 (g) 4.
Cripple wall studs exceeding 4 feet in height
shall be 3 inch by 4 inch or 2 inches by 6
inches when supporting 2 stories.
Section 2517 (g) 4
134 j Show plywood sheathing over exposed eaves, or
other weather exposed areas, is "bonded with
exterior glue " Plywood used for exterior
wall covering shall be the exterior type.
Section 2516 (i), 2516(g)3
Detail truss layout for 30" x 30" attic
access, if required for equipment in the
attic.
f-Ridges, hips, and valleys shall be at least
one size larger than supported rafters.
Section 2517 (h) 3.
IT open bean constructiOT, prcvice strap t^es
across the beams at the ridge support.
Section 2501 (b).
MECHANICAL (DHIFORM MECHANICAL CODE)
All heating, ventilating, and cooling systems and
appliances shall comply with the Uniform Mechanical
Code.
2/12/90
/
1/9
Show the siae, location and type of all heating
and cooling appliances or systems.
Show source of combustion air to furnace, per
Chapter 6, UMC.
Every dwelling unit shall be provided with
heating facilities capable of maintaining a
room temperature of 70 degrees F. at 3 feet
above the floor in all habitable rooms. Show
basis for compliance. UBC, Sec. 1212.
Show minimum 30" deep unobstructed working
space in front of furnace. Section 505, UMC.
, Furnace shall not be installed in any bedroom,
bathroom or in a closet or confined space with
access only through such room unless
specified as direct vent appliance, enclosed
furnace or electric heating appliance.
Section 704 UMC.
Show I.C B.O approval number for prefab
fireplace. Show height of chimney above roof
per I C B 0. approval or Table 37-B.
Show access to the attic containing equipment
to be minimum 30 inches by 30 inches. The
opening may be 22 inches by 30 inches if the
eauipoent can be removed through such opening.
Section 708 UMC.
Where equipment is installed in the attic, the
distance from the attic access to such
equipment shall not eyceed 20 feet.
Note that passageway to the attic furnace shall
be unobstructed and have continuous solid
flooring not less than 2k inches wide.
Section 708 UMC.
Show permanent electrical outlet and lighting
fixture controlled by a switch for the attic
furnace. Section 708 UMC.
Show details to comply vith Section 709 for
furnace under the floor, or Section 710 for
roof or outside furnace.
Note on plan: Gas vents and non-combustible
piping, in vails, passing through three floors
or less shall be effecti-vely craft stepped at
each floor or ceiling.
UBC, Section 1706 (a) 6
Provide dryer vent to outside. UMC, Section1903.
All wiring shall
Electrical Code.
comply with the National
Show on the plan the amperage of the
electrical service, the location of the
service panel and the location of any sub-
panels. If service is over 200 amps, submit
S,ingle line diagram, panel schedule and load
calculations.
. Show location of all electrical receptacles.
f
. Electrical receptacle locations and/or spacing
is not adequate in
Show at least one convenience outlet other
than outlets for laundry, etc., outdoors, in
garages and basements. NEC, Art. 210-52.
¥•
/•
1*6.
Note convenience outlets in bathrooms, kitchen
counter top(s) vithin 6 feet of the kitchen
sink, outdoors, and in garages and basements
(other than for laundry and similar equipment)
shall be GFI protected. NEC, Art. 210-8.
Note electrical system ground to be provided
per NEC, Art. 250-81.
PUMBING (UKIFORM PUMBIHG CODS)
Show water heater size, type and location on
plans. UPC, Section 1301.
Show source for providing combustion air to
fuel burning vater heater. If wall openings
in an enclosure are used, at least one-half of
the required opening area, shall extend into
the upper twelve inches of the enclosure and
one-half within the lower twelve inches. UPC,
Section 1307.
Fuel combustion vater heater shall not be
installed in bath or bedroom or in a closet
opening into bath or bedroom. UPC, Section
1309.
Provide adequate barrier to protect water
heater from vehicle damage. An 18" platform
for the water heater does not satisfy this
requirement. UPC, Section 1310.
Show T and P valve on water heater
route of discharge line to exterior.
UPC, Section 1007 (e).
and show
1/19/90
4
i#5.
}&6.
Show that water heater is adequately braced to
resist seismic forces, when not connected by
rigid pipe. UMC Section 504(d).
Show shower stall can accommodate a 30" circle
and has a minimum floor area of 1,024 sq. in
UPC 909 (d).
Provide clothes washer hook-up for each unit.
Title 24, Part 3.
NOISE INSULATION (DDFLEXES)
Show details of duplex common (party) walls and
floor/ceiling assemblies to achieve a Sound
Transmission Class (STC) rating in walls of 50
decibels and an Impact Insulation Class (IIC)
rating on floor/ceiling of 50 decibels.
Title 24.
Show how penetrations of assemblies for piping,
electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required sound
transmission rating. Title 24.
Provide insulation in walls and ceiling to
achieve STC of 50 between garage and living
area if garage use is not controlled by
resident. Title 24
ENERGY CONSERVATION
Provide plans, calculations and worksheets to
show compliance with current energy standards
The regulations require a properly completed
and properly signed Form CF-1R to be either
imprinted on the plans, taped to the plans or
"sticky backed" on the plans, to allow the
building inspector to readily compare the
actual construction with the requirements of
the approved energy design
All energy items shown on the plans must be in
agreement with the information shown on the
properly completed Form CF-1R
Specify on the building plans all of the
mandatory energy conservation requirements as
listed on the enclosure titled, "Mandatory
Energy Conservation Requirements"
Show the make, model and efficiency of the
space heating (or cooling) system and provide
heat loss calculations if the output exceeds
45,000 BTU/Hr.
3. For room additions, show that the glazing area
of the addition does not exceed 16% of the
newly-conditioned floor area, plus glazing
removed or relocated due to the addition.
Provide fluorescent general lighting in
kitchen(s) per CAC, Title 24, 2-5352(J).
CARLSBAD S.F.D. & DUPLEX SUPPLEMENT
/TVJ.75J Energy conservation design should be for Zone
7 B t-e.
l?b Floor drains must have auto-prime (city
f policy).
Note exhaust fans cannot be ductless type
(city policy)
New residential units must be pre-plumbed for
future solar water heating. Note "two roof
jacks must be installed" where the water
heater is in the one story garage and directly
below the most south facing roof (City
Ordinance No. 8093).
Note "two 3/4" copper pipes must be installed
to the most convenient future solar panel
location when the water heater is not in a one
story garage and is not directly below the
most south facing roof (City Ordinance No
8093).
All piping for present or future solar water
heating must be insulated when in areas that
are not heated or cooled by mechanical means
(city policy).
Incorporate the waterproofing details, on the
attached Policy 80-8, where interior living
space occurs below grade at the masonry
wall(s)
. Show on the Title Sheet on the plans, the
information required by the attached
Developmental Services Sheet 112383.
All new residential buildings, including
additions, require a soils report. Please
submit two copies. Exception: If a room
addition is limited to one story and 1000 sq.
ft in area, then a soils report is not
required. Esgil Corporation *-ill advise the
City to place u-ife.r soi*s nocice stasp on the
plans
Heavy timber framing, minimum 6" x 10" beams
/ and minimum 8" x 8" post, for the structural
beam and column supporting the fire separation
between the garage and living area above, is
acceptable if shown on the plans. (city
policy).
TH-i.twT 7Vf-£_oo
rrn '3 /vo 7"
OLSTH
2/26/90 10
All structures require a Class B roof covering, Enclosures:
except room additions. If a room addition
covers all of the existing building (2nd story 1.
addition), then the above exception doesn't
apply.
!&. City Ordinance 9792 requires two parking
spaces/unit with clear area of 20'x20' i.e. no
washing machines, etc. Show compliance. 3
Vtrf.All chimneys attached to any appliance or
fireplace that burns solid fuel shall be
equipped with an approved spark arrester. Ihe
net free area of the spark arrester shall be
not less than four times the net free ara of
the outlet of the chimney. The spark arrester
screen shall nave heat and corrosion resistance
equivalent to 12 gauge wire, 19 gauge
galvanized wire or 24 gauge stainless steel.
Openings shall not permit the passage of
spheres having a diameter larger than 1/2-inch
and shall not block the passage of spheres
having a diameter of less than 3/8-inch.
MISCELLANEOUS
Please see additional corrections, or remarks,
on the following page
[189*) To speed up the recheck process, note on this
list (or a copy) where each correction item has
been addressed, i.e , plan sheet, note or
detail number, calculation page, etc
(190) Please indicate here if any changes have been
made to the plans that are not a result of
corrections from this list If there are other
changes, please briefly describe them and where
they are located in the plans
Have changes been made to the plans not
resulting from this correction list' Please
check.
Yes No
The City of Carlsbad has contracted with Esgil
Corporation located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number
619/560-1468, to perform the plan check for your
project. If you have any qjestioj s rega.r;a-,g these
plan check items, please contact _
_ P f^
at Esgil Corporation If you have any questions
regarding City Building permit procedures, please
contact Carter Darnell at the City of Carlsbad, 2075
Las Palmas Dr., telephone 619/438-1161.
Thank you.
2/14/90IT
Datei.Jurisdiction CARLSBAD
Prepared by i
VALUATION AND PLAN CHECK FEE
Q Bldg. Dept,
D Esgil
PLAN CHECK NO. 7
BUILDING ADDRESS __
APPLICANT/CONTACT .
BUILDING OCCUPANCY
TYPE OF CONSTRUCTION
/0/V
PHONE NO.
DESIGNER PHONE
CONTRACTOR PHONE
BUILDING PORTION
/I £> P IT) J*J
Air Conditioning
Commercial
Residential
Res. or Comm.
Fire Sprinklers
Total Value
BUILDING ARE*
/3&
—
VALUATION
MULTIPLIER
6i
@
VALUE
5J6V
0
@
^357
Building Permit Fee $_
Plan Check Fee $
, oO
COMMENTS-
SHEET ( OF /12/87
BUILDING PLANCHECK
ENGINEERING CHECKLIST
DATE:g-xZ9-9O
PLANCHECK NO. 9f)-So7
1 2
S N
T D
C C
H H
E E
C C
K K
0D
3
R
D
C
H
E
C
K
D
/£>/•y /v/'if* U/fty
PROJECT ID: /3/3a>v\ /~)-£>£>s7?o*3
LEGAL
Site
REQUIREMENTS
Plan
1. Provide a fully dimensioned si
ITEM COMPLETE
ITEM INCOMPLETE -
NEEDS YOUR ACTION
ITEM SELECTED
I— I
n n
north arrow, property lines, easements, existing and proposed
structures, streets, existing street improvements, right-of-
way width and dimensioned setbacks.
Show on site plan: Finish floor elevations, pad elevations,
elevations of finish grade adjacent to building, existing
topographical lines, existing and proposed slopes, driveway
with percent (%) grade and (jfjTmage
I
3. Provide legal description and Assessors Parcel Number.
Discretionary Approval Compliance
4. No Discretionary approvals were required.
Project complies with all Engineering Conditions of Approval
for Project No. .
Project does not comply with the following Engineering
Conditions of Approval for Project No.
Conditions complied with by:
Field Review
7. Field review completed. No issues raised.
Date:.
8. Field Review completed. The following issues or discrepancies
with the site plan were found:
A. Site lacks adequate public improvements.
B. Existing drainage improvements not shown or in conflict
with site plan.
C. Site is served by overhead power lines.
D. Grading is required to access site, create pad or provide
for ultimate street improvement.
FRM0010 DH 08/29/89
Site access visibility problems exist. Provide onsite
turnaround or engineered solution to problem.
Other:
Dedication Requirements
9. No dedication required.
.10. Dedication required. Please have a registered Civil Engineer
or Land Surveyor prepare the appropriate legal description
together with an 8V' x 11" plat map and submit with a title
report and the required processing fee. All easement documents
must be approved and signed by owner(s) prior to issuance of
Building Permit. The description of the dedication is as
follows:
Dedication completed, Date:.By:.
Improvement Requirements
.11
.12.
No public
defective
improvements
improvements
required. SPECIAL NOTE Damaged or
found ad.iacent to building site must
be repaired to the satisfaction of the City inspector prior
to occupancy.
Public improvements required. This project requires
construction of public improvements pursuant to Section 18.40
of the City Code. Please have a registered Civil Engineer
prepare appropriate improvement plans and submit for separate
plancheck process through the Engineering Department.
Improvement plans must be approved, appropriate securities
posted and fees paid prior to issuance of permit. The required
improvements are: _
Improvement plans signed, Date:.By:.
FRM0010.DH 08/29/89
13. Improvements are required. Construction of the public
improvements may be deferred in accordance with Section 18.40
of the City Code. Please submit a letter requesting deferral
of the required improvements together with a recent title
report on the property and the appropriate processing fee so
we may prepare the necessary Future Improvement Agreement.
The Future Improvement Agreement must be signed, notarized and
approved by the City prior to issuance of a Building Permit.
Future Improvement Agreement completed, Date
By:
Grading Requirements
13a. Inadequate information available on site plan to make a
determination on grading requirements. Please provide more
detailed proposed and existing elevations and contours.
Include accurate estimates of the grading quantities (cut,
fill, import, export).
14. No grading required as determined by the information provided
on the site plan
15. Grading Permit required A separate grading plan prepared by
a registered Civil Engineer must be submitted for separate
plan check and approval through the Engineering Department.
NOTE: The Grading Permit must be issued and grading
substantially complete and found acceptable to the City
Inspector prior to issuance of Building Permits.
Grading Inspector sign off. Date- By
Miscellaneous Permits
X 16. Right-of-Way Permit not required.
17. Right-of-Way Permit required. A separate Right-of-Way Permit
issued by the Engineering Department is required for the
fol 1owi ng:
X 18. Sewer Permit is not required.
.19. Sewer Permit is required. A Sewer Permit is required
concurrent with Building Permit issuance. The fee required
is noted below in the fees section.
20. Industrial Waste Permit is not required.
FRM0010.DH 08/29/89
.21. Industrial Waste Permit is required. Applicant must complete
Industrial Waste Permit Applicantion Form and submit for City
approval prior to issuance of Building Permits. Permits must
be issued prior to occupancy.
Industrial Waste Permit accepted -
Date: By:
Fees Required
HJft 22. Park-in-Lieu Fee
Quadrant: Fee per Unit: Total
VA 23. Traffic Impact Fee
Fee Per Unit: Total Fee:.
Jift 24. Bridge and Thoroughfare Fee
Fee per Unit: Total
Al'/ft 25. Public Facilities Fee required.
A///3- 26 Facilities Management Fee Zone: Fee
_27. Sewer Fees „ Permit No EDU's
Fee-7
28. Sewer Lateral required:
Fee:
REMARKS:
ENGINEERING AUTHORIZATION TO ISSUE PERMIT
BY: Date:
FRM0010.DH 08/29/89
V V V
000
u u <->
eg <o a
a. a a.
nn
a
PLANNING CHECKLIST
Plan Check No. ^?- S"Q7 Address /O/t/ 77/^/>^
APN:
Planner Phone 438-1161
(Name)
Type of Project and Use
Zone Facilities Management Zone
Legend
Item Complete
Item Incomplete - Needs your action
1, 2, 3 Number in circle indicates plancheck number that deficiency
was identified
Environmental Review Required: YES
DATE OF COMPLETION:
NO A TYPE
Compliance with conditions of approval? If not, state conditions which
require action.
Conditions of Approval
Discretionary Action Required: YES
APPROVAL/RESO. NO.
PROJECT NO. -
NO >*C TYPE
DATE:
OTHER RELATED CASES:
Compliance with conditions of approval? If not, state conditions which
require action.
Conditions of Approval
D Coastal: YES X NO DATE OF APPROVAL:
Compliance with conditions of approval? If not, state conditions which
require action.
Conditions of Approval
inn
an
06 n
06 n
Elfin
Landscape Plan Required- YES NO
See attached submittal requirements for landscape plans
Site Plan:
1 Provide a fully dimensioned site plan drawn to scale Show
North arrow, property lines, easements, existing and proposed
structures, streets, existing street improvements, right-of-way
width and dimensioned setbacks.
2. Show on Site Plan: Finish floor elevations, elevations of finish
grade adjacent to building, existing topographical lines, existing
and proposed slopes and driveway.
3.
4.
Zoning:
1.
^-a
2.
3.
4.
Provide legal description of property.
Provide assessor's parcel number.
Setbacks:
Front: Required £.£? Shown
s^Int. Side:
Street Side:
Rear:
Lot coverage:
Height:
Parking:
Guest
Reauired B»7
Required
Required /7.y
Reauired t-Vo%
Required ^-^"s'
Spaces Required
Spaces Required
Shown
Shown
Shown
Shown
Shown
-*£•
^Afe
2-?^
Shown .p
Shown
Additional coonents and remarks have been made on the building plans. These
marked-up plans My be picked up at the Building Department. These marked-
up plans oust be resubaitted with the revised plans for this project.
Have plans been marked up?