HomeMy WebLinkAbout1026 BEACON BAY DR; ; CB151126; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
06-12-2015
Residential Permit
Permit No: CB151126
Building Inspection Request Line (760) 602-2725
Job Address:
1026 BEACON BAY DR CBAD
Permit Type:
RESDNTL Sub Type: RAID
Status: ISSUED
Parcel No:
2145301000 Lot #: 0
Applied: 04/14/2015
Valuation:
$80,934.00 Constuction Type: 5B
Entered By: RMA
Occupancy Group:
Reference #:
Plan Approved: 06/12/2015
# Dwelling Units:
0 Structure Type:
Issued: 06/12/2015
Bedrooms:
1 Bathrooms: 1
Inspect Area:
Orig PC #:
Plan Check #:
Project Title:
HAMPTON RES-498 SF ADDITION
& CONVERT 22 SF OF GARAGE TO BECOME HABITABLE FOR A TOTAL
OF 520 SF H 69 SF COVERED ENTRY
Applicant:
HAMPTON ROBERTJ&ANNE
1026 BEACON BAY DR
CARLSBAD CA 92011
760 802-8362
Owner:
HAMPTON ROBERT J&ANNE
1026 BEACON BAY DR
CARLSBAD CA 92011
Building Permit
$542.27
Meter Size
Add'I Building Permit Fee
$0.00
Add'I Red. Water Con. Fee
$0.00
Plan Check
$379.59
Meter Fee
$0.00
Add'I Plan Check Fee
$0.00
SDCWA Fee
$0.00
Plan Check Discount
$0.00
CFD Payoff Fee
$0.00
Strong Motion Fee
$10.52
PFF (3105540)
$0.00
Park in Lieu Fee
$0.00
PFF (4305540)
$0.00
Park Fee
$0.00
License Tax (3104193)
$0.00
LFM Fee
$0.00
License Tax (4304193)
$0.00
Bridge Fee
$0.00
Traffic Impact Fee (3105541)
$0.00
Other Bridge Fee
$0.00
Traffic Impact Fee (4305541)
$0.00
BTD #2 Fee
$0.00
Sidewalk Fee
$0.00
BTD #3 Fee
$0.00
PLUMBING TOTAL
$89.00
Renewal Fee
$0.00
ELECTRICAL TOTAL
$45.00
Add'I Renewal Fee
$0.00
MECHANICAL TOTAL
$58.45
Other Building Fee
$0.00
Housing Impact Fee
$0.00
HMP Fee
$0.00
Housing InLieu Fee
$0.00
Pot. Water Con. Fee
$0.00
Housing Credit Fee
$0.00
Meter Size
Master Drainage Fee
$0.00
Add'I Pot. Water Con. Fee
$0.00
Sewer Fee
$0.00
Red. Water Con. Fee
$0.00
Additional Fees
$0.00
Green Bldg Stands (SB1473) Fee
$4.00
Fire Sprinkler Fees
$0.00
Green Bldg Stands Plan Chk Fee
$0.00
TOTAL PERMIT FEES
$1,128.83
Total Fees: $1,128.83
Total Payments to Date:
$1,128.83 Balance Due:
$0.00
FINAL A PROVA
Inspector:-aL Date: Clearance:
NOTICE: Please take NOTICE that approval of your project includes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have oreviously been oiven a NOTICE similar to this or as to which the statute of limitations has i)reviously otherwise expired.
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Storm Water Pollution Prevention Plan (SWPPP) Permit
06-12-2015 Permit No:SW150154
Job Address:
1026 BEACON BAY DR CBAD
Permit Type:
SWPPP
Parcel No:
2145301000
Reference #:
CB#:
CB 151126
Project Title: HAMPTON RES-ADDITION
Applicant:
HAMPTON ROBERT J&ANNE
1026 BEACON BAY DR
CARLSBAD CA 92011
Emergency Contact:
ROBERT HAMPTON
760 802-8362
Status: ISSUED
Lot #: 0 Applied: 04/14/2015
Entered By: RMA
Issued: 06/12/2015
Inspect Area:
Tier: 1
Priority: L
Owner:
HAMPTON ROBERT J&ANNE
1026 BEACON BAY DR
CARLSBAD CA 92011
SWPPP Plan Check $48.00
SWPPP Inspections $58.00
Additional Fees $0.00
TOTAL PERMIT FEES $106.00
Total Fees: $106.00 Total Payments To Date: $106.00 Balance Due
DATE/ f7 NC
SIGNATURE
$0.00
,c FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: ❑ PLANNING ENGINEERING
' Building Permit Application
4LCity Of 1635 Faraday Ave., Carlsbad, CA 92008
�Sbad 01
in Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.aav
❑ BUILDING ❑ FIRE Q HEALTH D HAZMATIAPCD
Plan Check No.
Est. Value 43
Plan Ck. Deposit
Date L.! 1(4 1 S 1swPPP
JOB ADDRESS / SUITE#/SPACE#/UNIT# APR
-1-1" ,, /p,�(.4926-Beacon Bay Dr 1 214 - 530 - 10 - 00
Add 498 sq feet to existing residence, to include 1 bedroom, I bathroom,+kiiokm /living room.
J Gg single story on slab with wood grade construction.
{ ]Q
i7W
J
EXISTING USE
PRAMSED USE
GARAGE (SF)
PATIOS (S DECKS (SF)
FIREPLACE
AIR CONDITIONING
side yard
granny flat
262
YESOn NO[E]
YES[:]NO❑✓
�FIRESPRINIKLERS
YESONOE—]
APPLICANT NAME Robert Hampton
PROPERTY OWNER NAME
same
Prim Contact
ES
ADDRESS
(ADDRS
1026 Beacon Bay Dr
CITY
STATE ZIP
CITY
STATE
ZIP
Carlsbad Ca 92011
PHONE
FAX
PHONE
FAX
760 802.8362
760 448.6844
EMAIL
EMAIL
Robertna,solanavistabuilders.com
i
!DESIGN PROFESSIONAL Dale Combs/ CAPA Architecture
CONTRACTOR BUS. NAME
ADDRESS
ADDRESS
11787 Eucalvptus Hills Dr.
CITY
STATE ZIP
CITY
STATE
ZIP
Lakeside Ca 92040
PHONE
FAX
PHONE
FAX
_
619 443-3995
EMAIL
EMAIL
DWCarchitecturePcimail.com
STATE LIC. #
STATE LIC.#
CLASS
_
CITY BUS. LIC.#
C8621
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the
applicant for such permit to file a sig�ned statement that he is licensed pursuant to the provisions of the Contractor's License Law Chapter 9, commending with Section 7000 of Division 3 of the
Business and Professions Code) or tlTat he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 031.5 by any applicant for a permit subjects the applicant to a
civil penalty of not more than five hundred dollars ($5001).
Workers' Compensation Declaration:) hereby affirm under penalty of perjury one of the following declarations:
❑ I have and will maintain a certificate of consent to self -insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
❑ 1 have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance
Policy No.
Expiration Date
This section need not be completed if the permit is for one hundred dollars ($100) or less.
❑ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
)K CONTRACTOR SIGNATURE
AGENT DATE
1 hereby affirm that I am exempt from Contractor's License Law for the following reason: I
i
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale).
✓❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section Business and Professions Code for this reason: i
nally plan to provide the major labor and materials for construction of the proposed property improvement. DYes No
I e I have not) signed an application for a building permit for the proposed work. �r'LrS
3. 1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): y f
4. 1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address I phone / contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name /address / phone I type of work): �
i
PROPERTY OWNER SIGNATURE �� AGENT DATE
Inspection List
Permit#: CB151126 Type: RESDNTL RAD
Date Inspection Item
11/17/2015 89
Final Combo
11/17/2015 89
Final Combo
09/21/2015 17
Interior Lath/Drywall
09/21/2015 18
Exterior Lath/Drywall
09/15/2015 18
Exterior Lath/Drywall
09/03/2015 84
Rough Combo
08/21/2015 23
Gas/Test/Repairs
Inspector Act
RI
PD AP
Py AP
Py AP
Py NR
Py AP
MC AP
HAMPTON RES-498 SF ADDITION
& CONVERT 22 SF OF GARAGE TO BECO
Comments
RELOCATE METER TO NEW EXTERIOR
WALL. GMR E-MAILED TO SDGE
08/19/2015 13
Shear Panels/HD's
Py
AP
08/19/201515
Roof/Reroof
Py
PA
07/28/201511
Ftg/Foundation/Piers
Py
AP
07/10/2015 21
Underground/Under Floor
MC
AP WASTE TO P.O.0
Tuesday, November 17, 2015 Page 1 of 1
EsGil Corporation
In Partnership with Government for Building Safety
DATE: 06/09/2015
JURISDICTION: Carlsbad
PLAN CHECK NO.: 15-1126
PROJECT ADDRESS: 1024 Beacon Bay Drive
SET: III
❑ APPLICANT
❑ JURIS.
❑ PLAN REVIEWER
❑ FILE
PROJECT NAME: ttae a 2" Dwel1 ng Room Addition Covered Entry /Partial
Garage Conversion for Hampton Residence
❑ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
® The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
❑ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
❑ The applicant's copy of the check list has been sent to:
® EsGil Corporation staff did not advise the applicant that the plan check has been completed.
❑ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Email:
Mail Telephone Fax In Person
® REMARKS: City to place soils notice stamp on plans prior to issuance.
By: Ray Fuller (DA) Enclosures:
EsGil Corporation
❑ GA ❑ EJ ❑ MB ❑ PC 06/03/2015
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
EsGil Corporation
In (Partnership with Government for Buifding Safety
DATE: 05/15/15
JURISDICTION: Carlsbad
PLAN CHECK NO.: 15-1126
PROJECT ADDRESS: 1024 Beacon Bay Drive
SET: II
❑ APPLICANT
❑ JURIS.
❑ PLAN REVIEWER
❑ FILE
PROJECT NAME: Room Addition Covered Entry /Partial
Garage Conversion for Hampton Residence
❑ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
® The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
® The applicant's copy of the check list has been sent to:
Robert Hampton
❑ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
® EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Robert Hampton Telephone #: (760) 802-8362
Date contacted: (by: ) Email: Roberta-solanavistabuilders.com
Mail Telephone Fax In Person
❑ REMARKS:
By: Ray Fuller Enclosures:
EsGil Corporation
❑ GA ❑ EJ ❑ MB ❑ PC 05/12/15
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad 15-1126
05/15/15
NOTE: The items listed below are from the previous correction list. These
remaining items have not been adequately addressed. The numbers of the items
are from the previous check list and may not necessarily be in sequence. The
notes in bold font are current.
There was no response sheet sent back satiating if and where
corrections took place. Many of the issues were resolved when 2"d
dwelling was changed to an addition only by removing the kitchen.
1. Please make all corrections, as requested in the correction list. Submit THREE
sets of plans for residential projects). For expeditious processing, corrected sets
can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. Verify final sets of plans and any new calculations will be stamped and signed by
engineer and /or architect of record also. Sheets of plans were stamped but
not signed.
20. Residential ventilation requirements for the 2"d dwelling:
Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the
exterior. Note: CFM and noise rating ("Sone") must be specified on the
plans. No response and could not locate.
38. Please provide evidence that the engineer -of -record (or architect) has reviewed
the truss calculation package prepared by others (i.e., a "review" stamp on the
truss layout or a letter). No response and could not locate.
41. Engineer -of -record to address the ledger connection and shear transfer as
shown on 01/A3.0. The truss calculations do not seem to match what is
being proposed. It appears from truss calculations were designed for a 3"
ledger as noting length to be 137' and addition is 13'5". Please clarify.
42. Please recheck all details to verify that they are complete and/or correct. Could
not locate where width of footings was shown on the plans. Detail 11/S2
states to see plans and could not locate
Carlsbad 15-1126
05/15/15
• Note on this list (or a copy) where each correction item has been addressed,
i.e., plan sheet, note or detail number, calculation page, etc.
• Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe
them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction
list? Please indicate:
Yes (A No ( )
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468,
to perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Ray Fuller at Esgil Corporation. Thank
you.
,EsGil Corporation
In (Partnership with Government for Buifding Safety
DA"fE: 05/ 15/ 15
JURISDICTION: Car'bbad
PLAN CHECK NO, 15-1126
PROJECT ADDRESS: 1024 Beacon Bay Drive
SET: II
PPLICANT
JURIS.
❑ PLAN REVIEWER
❑ FILE
PROJECT NAM--:: Attaehed 2nd DwellingDwellingt Room Addition Covered Entry /Partial
Garage Conversion for Hampton Residence
❑ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
® The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
® The applicant's copy of the check list has been sent to:
Robert Hampton
❑ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
® EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Robert Hamptor
/ Date contacted: S/ IS (by:Y4 -
F_.-Mail Telephone Fax In Person
❑ REMARKS:
By: Ray Fuller
EsGil Corporation
❑GA ❑EJ ❑MB ❑PC
Telephone #: (760) 802-8362
Email: Robertso lanavistabuilders.corn
Enclosures:
05/12/15
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
t Carlsbad 15-1126
05/15/15
NOTE: The items listed below are from the previous correction list. These
remaining items have not been adequately addressed. The numbers of the items
are from the previous check list and may not necessarily be in sequence. The
notes in bold font are current.
There was no response sheet sent back satiating if and where
corrections took place. Many of the issues were resolved when 2nd
dwelling was changed to an addition only by removing the kitchen.
1. Please make all corrections, as requested in the correction list. Submit THREE
sets of plans for residential projects). For expeditious processing, corrected sets
can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. Verify final sets of plans and any new calculations will be stamped and signed by
engineer and /or architect of record also. Sheets of plans were stamped but
not signed.
20. Residential ventilation requirements for the 2"d dwelling:
• Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the
exterior. Note: CFM and noise rating ("Sone") must be specified on the
plans. No response and could not locate.
38. Please provide evidence that the engineer -of -record (or architect) has reviewed
the truss calculation package prepared by others (i.e., a "review" stamp on the
truss layout or a letter). No response and could not locate.
41. Engineer -of -record to address the ledger connection and shear transfer as
shown on 01/A3.0. The truss calculations do not seem to match what is
being proposed. It appears from truss calculations were designed for a 3"
ledger as noting length to be 137' and addition is 13'5". Please clarify.
42. Please recheck all details to verify that they are complete and/or correct. Could
not locate where width of footings was shown on the plans. Detail 11/S2
states to see plans and could not locate
{
Carlsbad 15-1126
05/15/15
• Note on this list (or a copy) where each correction item has been addressed,
i.e., plan sheet, note or detail number, calculation page, etc.
• Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe
them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction
list? Please indicate:
Yes ( ) No ( )
• The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468,
to perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Ray Fuller at Esgil Corporation. Thank
you.
EsGil Corporation
In (Partnership with Government for Buifding Safety
DATE: 04/22/ 15
JURISDICTION: Carlsbad
PLAN CHECK NO.: 15-1126
PROJECT ADDRESS: 1024 Beacon Bay Drive
SET: I
❑ LICANT
JURIS.
❑ PLAN REVIEWER
❑ FILE
PROJECT NAME: Attached 2nd Dwelling/Covered Entry /Partial Garage Conversion for
Hampton Residence
❑ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
® The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
® The applicant's copy of the check list has been sent to:
❑ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
® EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Robert Ham ton
Telephone #: (760) 802-8362
Date contacted: - ZZ (b 't ) Email: Robert(a-solanavistabuilders.com
kMailX Telephone X Fax in Person
❑ REMARKS:
By: Ray Fuller Enclosures:
EsGil Corporation
❑ GA ❑ EJ ❑ MB ❑ PC 04/16/15
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad 15-1126
04/22/15
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 15-1126 JURISDICTION: Carlsbad
PROJECT ADDRESS: 1024 Beacon Bay Drive
FLOOR AREA:
Dwelling 498
Covered Entry 69
Partial Garage Conversion 22
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 04/22/ 15
FOREWORD (PLEASE READ):
STORIES: Addition 1
HEIGHT: 12 ft per CRC
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 04/16/15
PLAN REVIEWER: Ray Fuller
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2013 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC,
2012 UPC, 2012 UMC and 2011 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2012 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 15-1126
04/22/15
1. Please make all corrections, as requested in the correction list. Submit THREE
sets of plans for residential projects). For expeditious processing, corrected sets
can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. The plans are referencing detail sheets and sheet S3 which reflect a different
architect and/or engineer -of -record with expired stamps. If want to use there
details then would need to obtain there written permission with current expiration
dates. (California Business and Professions Code).
3. Verify final sets of plans and the required calculations will be stamped and
signed by engineer and /or architect of record also.
4. Complete the attached City of Carlsbad special inspection form for items listed
on cover sheet.
5. Scope of work on cover sheet to include 69 sq ft of covered entry and 22 sq ft
garage conversion.
6. Please clearly indicate on the cover sheet of the plans whether the existing
residence has a fire sprinkler system installed or not and or if proposing to be fire
sprinklered. If existing structure is fire sprinklered then provide a note stating
that any additions/alterations will also be provided with an automatic residential
fire sprinkler system. Section R313.2. Verify with the City whether or not new 2"d
dwelling will be required to be fire sprinklered.
7. Please clearly indicate on the cover sheet of the plans whether the
existing house was built before or after 1994. For additions or improvements
to a residence built before 1994 please add the following note on the cover
sheet of the plans "All existing "noncompliant" fixtures (toilets that use more
than 1.6 gallons of water per flush, urinals that use more than one gallon of
water per flush, showerheads that have a flow capacity of more than 2.5 gallons
of water per minute, and interior faucets that emit more than 2.2 gallons of water
per minute) shall be replaced. Certification of compliance shall be given to the
building inspector prior to final permit approval. California SB407" .
Carlsbad 15-1126
04/22/15
8. Please update egress note 2 on A1.0 to state 44" to the bottom of the clear
opening as no longer measure to window sill per current code.
9. The plans did not address support for the bay window shown. Is this to be a
factory assembly? If so note this and if not then provide details for support of
frame to include either foundation or adequate knee braces with positive post to
wall and post to frame connections. Detail to include type member attaching to
and size, length and spacing of lags for example required for bottom of window
and roof framing member sizes, ledger, hips, ceiling joist size, spacing etc
10. Specify on the plans that any existing smoke alarms that are more than 10
years old will be replaced(for the main dwelling). Section R314.3.2.
11. Show or note that smoke alarms will be provided in all existing bedrooms,
hallways leading to bedrooms and on each floor (for the main dwelling). Section
R314.3.1
12. Show or note that carbon monoxide alarms will be provided outside each
separate sleeping area in the immediate vicinity of the bedrooms and on each
story(for the main dwelling) Section R315.2.
13. Missing requires smoke detector inside of proposed bedroom.
14. Show on the plans that countertop receptacle outlets comply with CEC Article
210.52(C): In kitchens a receptacle outlet shall be installed at each counter
space 12 inches or wider . See left of kitchen sink(Counter top spaces
separated by range tops, refrigerators, or sinks shall be considered as separate
counter top spaces).
15. An instantaneous water heater is shown on the plans. Please include a gas
pipe sizing design (isometric or pipe layout) for all gas loads. This cannot be a
deferred item.
a) The gas pipe sizing for a tank type water heater shall be based upon a
minimum 200,000 Btu gas input rating. Energy Standards 150.0(n).
16. Provide the following design requirements for gas water heaters installed to
serve individual dwelling units: ES 150.0(n)
♦ Provide on the plans a complete gas pipe design. The gas load for the
water heater shall be a minimum of 200,000 BTU/hr.
♦ A condensate drain installed no higher than 2" above the base of the
heater that also allows for gravity drainage.
♦ The "B" vent installed in a straight position (no bends) from the room
containing the water heater to the roof termination (for future possible
sleeving for high efficiency heater venting.)
♦ A 120 volt receptacle accessible to the heater installed within 3 feet.
♦ Pressure relief must extend to the exterior.
♦ Verify adequate combustion air is provided (unless mounted outdoors or
noted on plans to be direct vented)
Carlsbad 15-1126
04/22/15
17. In the garage, provide an adequate barrier to protect the water heater from
vehicle damage. An 18" platform for the water heater does not satisfy this
requirement. CPC Section 508.14.
18. All hot water piping sized %" or larger is required to be insulated as follows: 1"
pipe size or less: 1" thick insulation; larger pipe sizes require 11/2" thick insulation.
Note: In addition, the Y2" size hot water pipe to the kitchen sink is required to be
insulated. ES 150.00)2
19. If applies :Below grade hot water piping is required to be installed in a waterproof
and non -crushable sleeve or casing that allows for replacement of both the
piping and insulation. ES 150.O0)
20. Residential ventilation requirements for the 2nd dwelling:
• Kitchens require exhaust fans (either intermittent/100 cfm or continuous/5 air
changes/hour), ducted to the exterior. Detail compliance by including a
complying exhaust fan or a ducted range hood to the exterior. Note:
CFM and noise rating ("Sone") must be specified on the plans.
• Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the
exterior. Note: CFM and noise rating ("Sone") must be specified on the
plans.
Residential bathroom exhaust fans shall be energy star rated and shall be
control by a humidistat capable of an adjustment between 50 and 80%
humidity. CalGreen 4.506.1. Exception: Control by a humidistat is not
required if the bathroom exhaust fan is also the dwelling whole house
ventilation.
• Mechanical whole house ventilation must be provided. Include the following
information: Fan sizing (cfm), "Sone" specification, and the duct sizing,
location and length. Note: The information must match or exceed the design
found on CF-6R-MECH energy forms.
All fans installed to meet the preceding requirements must be specified at a
noise rating of a maximum 1 "Sone" (for the continuous use calculation) or 3
"Sone" (for the intermittent use calculation).
21. Include on the plans the following specifications for anv new electrical devices
being installed
a) Weather resistant type for any -new receptacles installed in damp or wet
locations (outside).
b) Arc -fault protection for all new outlets (not just receptacles) located in
rooms described in NEC 210.12(B): Family, living, bedrooms, dining,
halls, etc. Note 5 on A1.2 is reflectitn old rule of just bedrooms.
Carlsbad 15-1126
04/22/15
22. Please recheck all details to verify that they are complete and/or correct. See for
example where north and south appear to be reversed on A2.0 if plot plan is
correct. Recheck all locations.
23. Truss calculations do not appear to match what is shown on cross section B-B
as B-B shown A3.0?
24. Cross section B-B/ A3.0 is reflecting detail V/SD-1 and no detail provided.
Recheck all locations.
25. The floor plan must clearly denote which walls are required to be one rated and
provided with a minimum STC of 50 i.e. by cross hatching hours etc. Detail and
reference required 1 one hour /sound transmission assemblies to these walls.
26. It is unclear where separation is to take place. For example if the utility room is to
be used by both tenants then the separation would need to occur at all walls and
ceiling assembly above.
27. The garage would require a STC of 50 s appears to be for main dwelling. The
plan check cannot be completed until the fire and sound transmissions required
are clearly addressed on the plans.
28. Wall assemblies separating units in a duplex shall be of one -hour fire resistive
construction. Provide details of the assemblies. Section R302.3. Such wall
assemblies shall extend to the underside of the roof sheathing, where applicable.
Exceptions:
a) A fire -resistance rating of/2-hour shall be permitted in buildings equipped
throughout with an automatic sprinkler system installed in accordance with
NFPA 13.
b) Wall assemblies need not extend through attic spaces when the ceiling is
protected by not less than %-inch Type X gypsum board and an attic draft
stop constructed as specified in Section R302.12.1 is provided above and
along the wall assembly separating the dwellings. The structural framing
supporting the ceiling shall also be protected by not less than'/z -inch
gypsum board or equivalent.
29. Floor assemblies separating units in a duplex shall be of one -hour fire resistive
construction (Y2-hour if the building has an automatic sprinkler system). Provide
details of the assemblies. Section R302.3. Such assemblies shall extend to and
be tight to the exterior wall, where applicable. The supporting construction of fire -
rated floor assemblies shall have an equal or greater fire -rating. Section
R302.3.1. This would apply of laundry room is to be part of tenant space.
30. Provide a note on the plans stating: "Penetrations of fire -resistive walls, shall be
protected as required in CRC Section R302A."
31. Could not determine which if any of the doors are to be rated between the units?
Carlsbad 15-1126
04/22/15
32. Walls separating units in a duplex shall have a sound transmission class (STC)
of not less than 50. Additionally, floors must have an impact insulation class
(IIC) rating of not less than 50. CBC Section 1207 Show the location of and
provide details of the listed wall and floor/ceiling assemblies, and indicate the
listing agency and listing number for the tested ratings.
33. For duplexes only: The Title Sheet or Site Plan should clearly indicate if any
portion of the project is in a noise critical area (CNEL contours of 60 dB) as
shown on the City or County's General Plan. If no portion of the project is within a
noise critical area, provide a note on the Title Sheet stating: "This project is not
within a noise critical area (CNEL contour of 60 dB) as shown on the General
Plan". CBC Section 1207.11.
34. For duplexes only: If the project is located in noise critical areas (CNEL contours
of 60 dB) as shown on the City or County's General Plan, then an acoustical
analysis showing that the proposed building has been designed to limit noise in
habitable rooms to CNEL of forty-five dB is required. Where windows must be
closed to comply, it is necessary to provide mechanical ventilation capable of
providing at least two air changes per hour. Provide design. CBC Section
1207.11.
35. Per the NEC a minimum 100 amp panel must be provided to all dwellings. Sub
panel ok as long as tenant has direct access and not placed in bathroom, clothes
closet etc.
36. Framing /foundation notes on Sheet S2.0 are referencing details and sheets not
provided.
37. Provide the complete truss details and truss calculations for this project. For
example missing the center trusses .Specify truss identification numbers on the
plans (or provide a truss layout that matches plans. Truss design to include
FAU(s) in attic where applicable. Verify dead loads and clearances for
FAU/catwalk are provided and attic access framing when exceeds 24" in width.
The truss design drawings must contain all the information listed in Section
R802.10.
38. Please provide evidence that the engineer -of -record (or architect) has reviewed
the truss calculation package prepared by others (i.e., a "review" stamp on the
truss layout or a letter). CBC Section 107.3.4.2.
39. All truss to truss connections to be specified on either plans or truss calculations.
40. Detail all post -to -beam and post -to -footing connections and reference the detail
to the plan. If using built up columns then note minimum anchor bolts per panel
and show any lateral bracing i.e. if sheared. Any post located on concrete slabs
shall be supported so as to project a minimum of 1" above and any isolated piers
shall project at least 8 inches above ground level unless the posts are of
approved wood of natural resistance to decay or treated wood is used.
Carlsbad 15-1126
04/22/15
41. Engineer -of -record to address the ledger connection and shear transfer as
shown on 01/A3.0.
42. Reference all details to applicable locations and cross out or remove those that
do not apply.
43. Plans deviating from conventional wood frame construction shall have the
structural portions signed and sealed by the California state licensed engineer or
architect responsible for their preparation, along with structural calculations.
The plans do not comply with conventional framing for lateral. Some examples
are listed below. :
a) Braced wall panels must occur a maximum of 25 ft o.c. at interior both in
the transverse and longitudinal direction
b) Braced wall panels must start at each end of each braced wall line.
c) All braced wall panels must be detailed with a detail reflecting brace wall
panel extending to roof sheathing.
d) If using the exception of 10 ft rule then the maximum combined distance
from end of braced wall line is 10 ft but only it either a 2 ft return panels
required at each corner or a hold down placed closest to corner capable
of resisting 1800 #'s. Would need to specify for example type of hold
down, correct SSTB size (if not a strap) and size member attaching hold
down to i.e. 4x etc
e) Need to provide shear transfer details to include edge nailing of the roof
diaphragm to full depth blocks at the plate lines and transfer from blocks
to plates i.e. A-35's with spacing noted.
f) Braced wall lengths less thsat 4 ft require hold downs at each end of each
panel (minimum length is 2'8").
44. Where removing existing stucco shear please show on the plans how remaining
walls will comply with conventional construction provisions ( R602- Conventional
Light -Frame Construction of the California Building Code) or provide an
engineering analysis for the lateral load resistance of the wall(s) in question . The
plans did not address existing common wall to proposed addition where it
appears proposing to be the removing stucco shear. Plans to reflect how these
wall (s) be laterally braced to roof sheathing as the additional'/2 of the loads
from proposed room addition and removal of stucco required that this be
replaced with brace wall panels extending to roof sheathing. Specify type, length
of panels, nail size and spacing and shear transfer.
45. The plans did not address existing upper walls where removing existing stucco
shear at upper floor in order to add ledger/roofing. How will required shear be
able to transfer to bottom sill plate with the removal of this shear? The
additional Y2 of the loads from proposed room addition require this to be sheared
and shear transfer details provided to reflect edge nailing of existing stucco
shear above (minimum 1 x 4/1 x6 generally) counter flashing thru blocks to
ledger below and transfer from shear paneling to block or upper floor to be
sheared?
Carlsbad 15-1126
04/22/15
46. Notes 13 and 18 on A3.0 conflict with notes on S2.0 and details on SD3.
47. Plate washers are required to be 0.229"x3"x3". Section R602.11.1
RESIDENTIAL GREEN BUILDING STANDARDS
The California Building Standards Commission has adopted the Green Building
Standards Code which became effective January 1, 2011 and must be enforced by the
local building official. The following mandatory requirements for residential construction
must be included on your plans. CGC Section 101.3. The Standards apply to newly
constructed residential buildings, along with additions/alterations that increase the
building's conditioned area, volume or size. CGC Section 303.1.1. Provide a sheet on
the plans labeled "Green Building Code Requirements" and include the following
notes as applicable.
48. Recycling. Note on the plans that a minimum of 50% of construction waste is to
be recycled. CGC 4.408.1.
49. Recycling. Note on the plans that the contractor shall submit a Construction
Waste Management Plan to the jurisdiction agency that regulates waste
management, per CGC 4.408.2.
50. Operation and maintenance manual. Note on the plans that the builder is to
provide an operation manual (containing information for maintaining appliances,
etc.) for the owner at the time of final inspection. CGC 4.410.1.
51. Pollutant control. Note on the plans that during construction, ends of duct
openings are to be sealed, and mechanical equipment is to be covered.
52. Pollutant control. Note on the plans that VOC's must comply with the
limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and
4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood
Products. CGC 4.504.2.
53. Interior moisture control. Note on the plans that the moisture content of wood
shall not exceed 19% before it is enclosed in construction. The moisture content
needs to be certified by one of 3 methods specified in Section 4.505.3. Building
materials with visible signs of water damage should not be used in construction.
The moisture content must be determined by the contractor by one of the
methods listed in CGC 4.505.3.
54. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star
rated, vented directly to the outside and controlled by a humidistat. CGC
4.506.1.
55. Note on the plans that prior to final inspection the licensed contractor, architect
or engineer in responsible charge of the overall construction must provide to the
building department official written verification that all applicable provisions
from the Green Building Standards Code have been implemented as part of the
construction. CGC 102.3.
Carlsbad 15-1126
04/22/15
• CITY of CARLSBAD REQUIREMENTS
56. All new residential buildings, including additions, require a soils report. An update
letter is required if the report is more than 3 years old. If a room addition is less
than 500 sq. ft. in area and only one story, then a soils report is not required. The
maximum allowable soil bearing value used in any design must be 1000 psf
for this exception.
57. When special inspection is required, the designer shall complete the city's "Special
Inspection Agreement".
58. All new residential units shall include plumbing specifically designed to allow the
later installation of a system which utilizes solar energy as the primary means of
heating domestic potable water. No building permit shall be issued unless the
plumbing required pursuant to this section is indicated in the building plans.
END OF PRELIMINARY REVIEW. Complete recheck required when
architectural issues resolved and plans and calculations reviewed by
engineer of record to verify that they are complete and that they reflect a
complete vertical and lateral load path from roof sheathing to foundation
below.
Note on this list (or a copy) where each correction item has been addressed,
i.e., plan sheet, note or detail number, calculation page, etc.
• Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe
them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction
list? Please indicate:
Yes ( ) No ( )
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468,
to perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Ray Fuller at Esgil Corporation. Thank
you.
Carlsbad 15-1126
04/22/15
CITY OF
CARLSIDAD
SPECIAL INSPECTION
AGREEMENT
B-45
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed
requires special inspection, structural observation and construction material testing.
'roject/Permit:
Project Add
A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNERIAUTHORIZED AGENT. Please check if you are Owner -Builder
❑. (If you checked as owner -builder you must also complete Section B of this agreement.)
Name: (Please print)
(Firsq
Mailing Address:
Email
(M L)
Phone:
LIM
I am: ❑Property Owner ❑Property Owner's Agent of Record ❑Architect of Record ClEngineer of Record
State of California Registration
Expiration Date:
AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read,
understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural
observations, construction materials testing and off -site fabrication of building components, as prescribed in the statement of
special inspections noted on the approved plans and, as required by the California Building Code.
Signatu
Date:
B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the
contractor / builder / owner -builder.
Contractor's Company Name:_
Name: (Please print)
(First) {M L}
Mailing Address:
Email
State of California Contractor's License Number:
Please check if you are Owner -Builder O
EME
Phone:
Expiration Date:
1 acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on
the approved plans;
I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the
building official;
I will have in -place procedures for exercising control within our (the contractor's) organization, for the method and
frequency of reporting and the distribution of the reports, and
I certify that I will have a qualified person within our (the contractor's) organization to exercise such control.
1 will provide a final report / letter in compliance with CBC Section 1704.1.2 prior to requesting final
inspection.
B-45
Page 1 of 1
Date:
Rev. 08111
Carlsbad 15-1126
04/22/15
ADO NOT PAY- THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 15-1126
PREPARED BY: Ray Fuller DATE: 04/22/ 15
BUILDING ADDRESS: 1024 Beacon Bay Drive
BUILDING OCCUPANCY: R3 U TYPE OF CONSTRUCTION VB
BUILDING
PORTION
AREA
( Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
2nd Dwelling
498
157.88
78,624
Covered Entry
69
11.48
792
Garage Convert
22
68.98
1,518
Air Conditioning
Fire Sprinklers
TOTAL VALUE
j
80,934
Jurisdiction Code lcb IBy Ordinance I
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review: F,-/ I Complete Review ❑ Structural Only
❑ Repetitive Fee El Other '
Repeats ❑ Hourly Hr. @
- -- EsGil Fee
$538.43
$349.98
Comments: In addition to the above fee, an additional fee of $43 is due (.5 hour @
$86/hr.) for the CalGreen review.
Sheet 1 of 1
macvalue.doc +
I
i*
CITY OF
AIR
PLAN CHECK
REVIEW
TRANSMITTAL
DATE:04/16/2015 PROJECT NAME: HAMPTON RESIDENCE
PLAN CHECK NO: 1 SET#: 1 ADDRESS: 1026 BEACON BAY DR
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www.carlsbadca.gov
PROJECT ID: CB151126
APN: 214-530-10-00
VALUATION: 78,624
This plan check review is complete and has been APPROVED by the ENGINEERING
Division.
By: VALRAY NELSON
A Final, -Inspection by the ENGINEERING Division is required Yes No
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
y C 0 F� I T' 1-'� " t C'Ij P I X. I NEED 1,1 jA IA
Plan Check Comments have been sent to: ROBERT@SOLANAVISTABUILDERS.COM
You rni,;iy also have corrc,,:ctions from one or more of the divisions listed below. Approval
'?'c" i fhese di'visions may be required for to tile issucance of a buildrft permit.
Plans shiould include coirt-C'tiotlls frorn all divisions.
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING ENGINEERING FIRE PREVENTION
760-602-4610 760-602-2750 760-602-4665
Chris.Sexton@carlsbadca.gov
Gina.Ruiz@carlsbadcaj� v
o
Remarks:
Kathleen Lawrence
760-602-2741
Kathleen.Lawrence@carisbadc.a.,gov
Linda.Ontiveros@carisbadea.gov
Gregory.Ryan@carlsba—d—c—a-.go—v
qynthia.Wong@carIsbadca.jdov
ValRay Marshall
760-602-2773
Val Ray.Marshall@carisbadca.gov Dominic Fieri@carisbadca.gov
A0 0 3`� :.A jj"�
.1
I]
Set # 1
Any outstand►ny issues will he marked with X . Make the necessary corrections jar
compliance with applicable codes and standiards. Submit cot-rected Mans and/or
specifications to the Guildiny division for re -submittal to the Engineer-iny division.
henm that conform to permit requirements are marked with V
1. SITE PLAN
Provide a fully dimensioned site plan drawn to scale.
Show:
1` North arro V, Existing &pw
roposed structures
✓ Existing street improvements
✓ Property lines (show all dimensions)
✓ Easements
Right-of-way width & adjacent streets
Show on site plan:
Drainage patterns
✓ Driveway widths
Existing or proposed sewer lateral
Existing or proposed water service
Submit on signed approved plans:
DWG No.
Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining
street or an approved drainage course.
ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale
5' away from building".
Existing & proposed slopes and topography
Size, location, alignment of existing or proposed sewer and water service(s) that serves the project.
Each unit requires a separate service; however, second dwelling units and apartment complexes are an
exception.
Sewer and water laterals should not be located within proposed driveways, per standards.
Include on title sheet:
V Site address
,/ Assessor's parcel number
,t Legal description/lot number
For commercial/industrial buildings and tenant improvement projects, include: total building
square footage with the square footage for each different use, existing sewer permits
showing square footage of different uses (manufacturing, warehouse, office, etc.) previously
approved.
Show all existing use of SF and new proposed use of SF.
Example:
Tenant improvement for 3500 SF of warehouse to 3500 SF of office.
Lot/Map No.: 47 13282
Subdivision/Tract: CT 32-0
Reference No(s):
E-36
Page 2 of 6
REV 6/01/12
Set #
2. DISCRETIONARY APPROVAL COMPLIANCE
NIA Project does not comply with the following engineering conditions of approval for project no.:
5Y Q
3. DEDICATION REQUIREMENTS
I
Dedication for all street rights -of -way adjacent to the building site and any storm drain or
utility easements on the building site is required for all new buildings and for remodels with a
value at or exceeding $-24,000---pursuant to Carlsbad Municipal Code Section 18.40.030.
For single family residence, easement dedication will be completed by the City of Carlsbad,
costitt 5-m.
Dedication required as follows:
4. IMPROVEMENT REQUIREMENTS
All needed public improvements upon and adjacent to the building site must be constructed
NIA at time of building construction whenever the value of the construction exceeds
$124,=-W, pursuant to Carlsbad Municipal Code Section 18.40.040.
Public improvements required as follows:
sidewalk, underground utilities
Construction of the public improvements must be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or current grant
deed on the property and processing fee of 44 -Q4-so we may prepare the necessary
Neighborhood Improvement Agreement. This agreement must be signed, notarized and
approved by the city prior to issuance of a building permit. Processing fee $157.00.
Future public improvements required as follows:
CURB, GUTTER, SIDEWALK
UNDERGROUND UTILITIES
E-36 Page 3 of 6
REV 6/30110
11
zw
Set # 1
5. GRADING PERMIT REQUIREMENTS
The conditions that require a grading permit are found in Section 15.16 of the Municipal
Code.
Inadequate information available on site plan to make a determination on grading
requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and
remedial). This information must be included on the plans. If no grading is proposed
write: "NO GRADING"
Grading Permit required. NOTE: The grading permit must be issued and rough grading
approval obtained prior to issuance of a building permit.
Graded Pad Certification required. (Note: Pad certification may be required even if a grading
permit is not required.) All required documentation must be provided to your Engineering
Construction Inspector . The inspector will then
provide the engineering counter with a release for the building permit.
J No grading permit required.
Minor Grading Permit required. See attached marked -up submittal checklist for project -
specific requirements.
6. MISCELLANEOUS PERMITS
RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work
adjacent to the public right-of-way. Types of work include, but are not limited to: street
improvements, tree trimming, driveway construction, tying into public storm drain, sewer and
water utilities.
Right-of-way permit required for: Driveway
E-36 Page 4 of 6 REV 6/01112
0
Set # 1
7. STORM WATER
Construction Compliance
,/ Project Threat Assessment Form complete.
Enclosed Project Threat Assessment Form incomplete.
/ Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form
and return (SW 15-0154 )
Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2
SWPPP, payment of processing fee and review by city.
Post -Development (SUSMP) Compliance
V Storm Water Standards Questionnaire complete.
Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign
the questionnaire and resubmit with next submittal.
Project is subject to Standard Storm Water Requirements. See city Standard Urban
Storm Water Management Plan (SUSMP) for reference.
http://www carlsbadca qov(business/buildinglDocuments/EngStandsw-stds-vol4-ch2.pdf
Project needs to incorporate low impact development strategies throughout in one or
more of the following ways:
Rainwater harvesting (rain barrels or cistern)
Vegetated Roof
Bio-retentions cell/rain garden
Pervious pavement/pavers
Flow -through planter/vegetated or rock drip line
Vegetated swales or rock infiltration swales
Downspouts disconnect and discharge over landscape
Other:
E-36 Page 5 of 6 REV 6/01/12
Set # 1
9. WATER METER REVIEW
Domestic (potable) Use
What size meter is required?
FYI Where a residential unit is required to have an automatic fire
extinguishing system, the minimum meter size shall be a 1" meter.
NOTE: the connection fee, SDCWA system capacity charge and the
water treatment capacity charge will be based on the size of the meter
necessary to meet the water use requirements.
FYI For residential units the minimum size meter shall be 5/8", except where
the residential unit is larger than 3,500 square feet or on a lot larger than
one quarter (1/4) acre where the meter size shall be 3/4".
8. FEES
Required fees have been entered in building permit.
Drainage fee applicable
Added square feet over 500
Added square footage in last two years? yes no
Permit No.
Permit No.
Project built after 1980 yes no
Impervious surface > 50% yes no
Impact unconstructed facility yes no
V, Fire sprinklers required yes no (is addition over 150' from center line)
Upgrade yes no
No fees required
10. Additional Comments
NEEDS TO GET CDP APPROVAL THEN I CAN RE-EVALUATE
Attachments: Engineering Application
Storm Water Form
E-36 Page 6 of 6
Right -of -Way Application/Info. ReferenceDocuments
REV 6/01/12
Fee Calculation Worksheet
ENGINEERING DIVISION
Prepared by: 04/16/2015 Date: 0411612015 GEO DATA: LFMZ: 1 B&T:
Address: 1026 BEACON BAY DR Bldg. Permit #: CB151126
Fees Update by: Date: 0411612015 Fees Update by: Date:
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use: SFD
Sq.Ft./Units 1
EDU's: 1
Types of Use:
Sq.Ft./Units
EDU's:
Types of Use:
Sq.Ft./Units
EDU's:
Types of Use:
Sq.Ft./Units
EDU's:
ADT CALCULATIONS: List types and
square footages for all uses.
Types of Use: SFD
Sq.Ft./Units
ADT's:
Types of Use:
Sq.Ft./Units
ADT's:
Types of Use:
Sq.Ft./Units
ADT's:
Types of Use:
Sq.Ft./Units
ADT's:
FEES REQUIRED:
Within CFD: YES (no bridge & thoroughfare fee in District #1, reduces
Traffic Impact Fee)
1, PARK -IN -LIEU FEE: NW QUADRANT ✓ NE QUADRANT
SE QUADARANT
ADT'S/UNITS:
I X FEE/ADT:
=$
2.TRAFFIC IMPACT FEE:
ADT'S/UNIT
X FEE/ADT:
=$
3. BRIDGE & THOROUGHFARE FEE:
DIST. #1
DIST.#2
ADT'S/UNITS:
FEE/ADT:
=$
4. FACILITIES MANAGEMENT FEE
ZONE:
ADT'S/UNITS:
X FEE/SQ,FT./UNIT:
=$
5. SEWER FEE
EDU's 1 I X
BENEFIT AREA: G
EDU's 1 I X
6. DRAINAGE FEES: needs to PLDA:
ACRES: I X
7. POTABLE WATER FEES:
UNITS I CODE
FEE/EDU: 842 1 =$ 842
FEE/EDU: 659 I =$ 659
HIGH MEDIUM
FEE/AC: I =$
NO
SW QUADRANT
DIST.#3
-11
a
7
LOW
CONN. FEE I METER FEE I SDCWA FEE
TOTAL
u
.e ,
CITY OF
SBAD
STORM WATER COMPLIANCE FORM
TIER 1 CONSTRUCTION SWPPP
E-29
STORM WATER COMPLIANCE CERTIFICATE
✓ . My project is not in a category of permit types exempt from the Construction
SWPPP requirements
✓ My project is not located inside or within 200 feet of an environmentally
sensitive area with a significant potential for contributing pollutants to nearby
receiving waters by way of stone water runoff or non -storm water
discharge(s).
✓ My project does not require a grading plan pursuant to the Carlsbad
Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code)
✓ My project will not result in 2,500 square feet or more of soils disturbance
including any associated construction staging, stockpiling, pavement
removal, equipment storage, refueling and maintenance areas that meets
one or more of the additional following criteria:
• located within 200 feet of an environmentally sensitive area or the
Pacific Ocean; and/or,
• disturbed area is located on a slope with a grade at or exceeding 5
horizontal to 1 vertical; and/or
• disturbed area is located along or within 30 feet of a storm drain inlet, an
open drainage channel or watercourse; and/or
• construction will be initiated during the rainy season or will extend into
the rainy season (Oct. 1 through April 30).
1 CERTIFY TO THE BEST OF MY KNOWLEDGE THAT ALL OF THE ABOVE
CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMITTING
FOR CITY APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN
ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS.
I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST
MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES
TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE
MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE
THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED
POLLUTANTS; AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH
THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE
DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE
CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF
CARLSBAD.
OWNER(S)/OWNER' AGENT rjAME (PRINT)
OWNER(S)/OWNER'S AGENT NAME (SIGNATURE) DATE'
STORM WATER POLLUTION PREVENTION NOTES
1. ALL NECESSARY EQUIPMENT AND MATERIALS
SHALL BE AVAILABLE ON SITE TO FACILITATE
RAPID INSTALLATION OF EROSION AND
SEDIMENT CONTROL BMPS WHEN RAIN IS
EMINENT.
2. THE OWNER/CONTRACTOR SHALL RESTORE
ALL EROSION CONTROL DEVICES TO
WORKING ORDER TO THE SATISFACTION OF
THE CITY ENGINEER AFTER EACH RUN-OFF
PRODUCING RAINFALL.
3. THE OWNER/CONTRACTOR SHALL INSTALL
ADDITIONAL EROSION CONTROL MEASURES
AS MAY BE REQUIRED BY THE CITY
ENGINEERING OR BUILDING INSPECTOR DUE
TO UNCOMPLETED GRADING OPERATIONS OR
UNFORESEEN CIRCUMSTANCES WHICH MAY
ARISE.
4. ALL REMOVABLE PROTECTIVE DEVICES SHALL
BE IN PLACE AT THE END OF EACH WORKING
DAY WHEN THE FIVE (5) DAY RAIN
PROBABILITY FORECAST EXCEEDS FORTY
PERCENT (40%). SILT AND OTHER DEBRIS
SHALL BE REMOVED AFTER EACH RAINFALL.
5. ALL GRAVEL BAGS SHALL BE BURLAP TYPE
WITH 3/4 INCH MINIMUM AGGREGATE.
6. ADEQUATE EROSION AND SEDIMENT
CONTROL AND PERIMETER PROTECTION BEST
MANAGEMENT PRACTICE MEASURES MUST BE
INSTALLED AND MAINTAINED.
SPECIAL NOTES
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carisbadca.gov
PROJECT INFORMATION
Site Address:/UL!!/ �(i° C. C✓/ ,UGC
Assessor's Parcel Numrber:L�II'S�� fo' 6
Project ID:
Construction Permit No.: is/ 12tL
Estimated Construction Start Date
Project Duration Months
Emergency Contact:
Name:
24 hour Phonei/�✓7i�.�
Perceived Threat to Storm Water Quality
❑ Medium
XLow
If medium box is checked, must attach a site plan
sheet showing proposed work area and location
of proposed structural BMPs
For City Use Only
CITY OF CARLSBAD
STANDARD TIER 1 SWPPP
Approved By: 1�r
Date: 11.j�
" /(tc lS
Pt-.
E-29 Page 1 of 3 REV 4/30/10
A
CITY OF
CARLSBAD
STORM WATER
STANDARDS
QUESTIONNAIRE
E-34
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carisbadca.gov
%1U1I I ICLC LI It; uesuurls oelow regaruing your reaeveio ment project: YES
Does the redevelopment project result in the creation or replacement of impervious surface in an amount of less than
50% of the surface area of the previously existinq development?
If you answered "yes," the structural BMP's required for Priority Development Projects apply only to the creation or replacement of
impervious surface and not the entire development. Go to step 4, check the "my project meets PDP requirements" box and
complete applicant information.
If you answered "no," the structural BMP's required for Priority Development Projects apply to the entire development. Go to step 4,
check the "my project meets PDP requirements" box and complete applicant information
❑ My project meets PRIORITY DEVELOPMENT PROJECT (PDP) requirements and must comply with additional stormwater
criteria per the SUSMP and I understand I must prepare a Storm Water Management Plan for submittal at time of application.
I understand flow control (hydromodification) requirements may apply to my project. Refer to SUSMP for details.
My project does not meet PDP requirements and must only comply with STANDARD STORMWATER REQUIREMENTS per
the SUSMP. As part of these requirements, I will incorporate low impact development strategies throughout my project.
Applicant Information and Signature Box
App n>i Name:
Applicant Signature:
A%essor's Parcel Number(s):
c/ - s 3 O i(2(
Applicant Title:
Date:
This Box for City Use Only
y Concurrence:
YES
NO
- A/ \
[Date:
Iject
ID: 0 1
" Environmentally Sensitive Areas include but are not limited to all Clean Water Act Section 303(d) impaired water bodies; areas
designated as Areas of Special Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the
San Diego Basin (1994) and amendments); water bodies designated with the RARE beneficial use by the State Water Resources
Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); areas designated as preserves or their
quivalent under the Multi Species Conservation Program within the Cities and County of San Diego; and any other equivalent
environmentally sensitive areas which have been identified by the Copermittees.
E-34 Page 3 of 3 Effective 6/27/13
Erosion Control
Tracking
Non -Storm Water
Waste Management and Materials
BMPs
Sediment Control BMPs
Control
Management BMPs
Pollution Control BMPs
BMPs
�\
C
C
�
C
0
U
0
U
c
C
m
E
C
E
E
-o
Best Management Practice
u1
L
-O N
CO fO
3
�.
m
CC
`
Co
a
N
l6
)
1
1
N
o
W
0
O
6Zi
C
0
\
�
_O_"
Cr 7
W
"O
CO
�
�,
N
l6
m
f0
C
g
C
M
3
m
(BMP) Description 4
W
N
o�
C_
E
rn
6)
(D rn
Co
C
U
rn
U
41
c
a
6S
c
N
N
2i
a)
N
3
Y 6)
U
C
C
6)
O
CU
m
3 C
�`
1.
6) W
N cU
O
U_
@ 1
>
N
CO
N C
l6
6)
'd
67
'O
6)
N
�O
CO
L C
d
Il
Y
U
of
]
7
U
L
U`
E 6)
�
N
N
N 3
m
m
j
N
C
7
O
O
O
O_
—
D
C
6)
O
N
O
�
_-.
6)
L
L_
N
CO
(6
O O
d
c`
(6 p)
M o
76
l6
D_
O
o_
L
6) —
i
c6
(6
O
(!)
O_
rn
O
(n
N
(6
2
O
U
(.�
W
(!)
CJ
(n
(n
U
C7
(n
(n
(n
Cn
(n
CASQA Designation 4
r
w
rn
�
��
v
"'
(9
1—
0?
o
7
—
N
—
C?
�
C?�
N
M
v
u?
co
60
0
0
c5
�
w
u]
w
w
w
w
w
of
of
(n
v)
u)
cb
w
w
w
w
CO
rn
U)
<n
rn
cn
rn
w
z
z
z
z
2
2
2
2
2
2
2
Construction Activity
Grading/Soil Disturbance
Trench in/Excavation
v
Stockpiling
Drilling/Boring
Concrete/Asphalt Saw
cutting
Concrete flatwork
Paving
Conduit/Pipe Installation
Stucco/Mortar Work
Waste Disposal
Staging/Lay Down Area
Equipment Maintenance
and Fuelin
Hazardous Substance
Use/Storage
Dewaterin
Site Access Across Dirt
Other (list):
Instructions: Begin by reviewing the list of construction activities and checking the box to the left of any activity that will occur during the proposed construction. Add any other activity descriptions in the
blank activity description boxes provided for that purpose and place a check in the box immediately to the left of the added activity description. For each activity descrribed, pick one or more best
management practices (BMPs) from the list located along the top of the form. Then place an X in the box at the place where the activity row intersects with the BMP column. Do this for each activity that was
checked off and for each of the selected BMPs selected from the list. For Example —If the project includes site access across dirt, then check the box to the left of "Site Access Across DirtThen review
the list for something that applies such as "Stabilized Construction Ingress/Egress" under Tracking Control. Follow along the "Site Access Across Dirt" row until you get to the "Stabilized Construction
Ingress/Egress" column and place an X in the box where the two meet. As another example say the project included a stockpile that you intend to cover with a plastic sheet. Since plastic sheeting is not on
the list of BMPs, then write in "Cover with Plastic" in the blank column under the heading Erosion Control BMPs. Then place an X in the box where the "Stockpiling" row intersects the new "Cover with
Plastic column.
To learn more about what each BMP description means, you may wish to review the BMP Reference Handout prepared to assist applicants in the selection of appropriate Best Management Practice
measures. The reference also explains the California Stormwater Quality Association (CASQA) designation and how to apply the various selected BMPs to a project.
E_29 Page 2 of 3 REV 4/30/10
CITY OF
CARLSBAD
STORM WATER
COMPLIANCE
ASSESSMENT
B-24
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
I am applying to the City of Carlsbad for the following type(s) of construction permit:
�4 Building Permit
❑ Right -of -Way Permit
❑ My project is categorically EXEMPT from
Electrical
Patio/Deck
the requirement to prepare a storm water
Fire Additional
Alarm
Photo VoltaicFire
Re -Roofing
pollution prevention plan (SWPPP) because it
Fixed Systems
Sign
only requires issuance of one or more of the
Mechanical
Spa -Factory
following permit types:
Mobile Home
Sprinkler
Plumbing
Water Discharge
Project Storm Water Threat Assessment Criteria*
No ThifeatAssessment Criteria
My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because
it meets the "no threat" assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier
Level. My project does not meet any of the High, Moderate or Low Threat criteria described below.
Tier 1 - Low Threat Assessment Criteria
❑ My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project
meets one or more of the following criteria:
• Results in some soil disturbance; and/or
• Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling).
Tier 2 - Moderate Threat Assessment Criteria
❑ My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria:
• Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or,
• Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement
removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria:
• Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or
• Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or
• Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or
• Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30).
Tier 3 - Significant Threat Assessment Criteria
❑ My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or
❑ My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, refueling and maintenance areas: or,
❑ My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant
potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non -storm water discharge(s).
1 certify to the best of my knowledge that the above
checked statements are true and correct 1 understand
and acknowledge that even though this project does
not require preparation of a construction SWPP,1 must
still adhere to, and at all times during construction
activities for the permit types) check above comply
with the storm water best management practices
pursuant to Title 15 of the Carlsbad Municipal Code
and to City Standards.
"The City Engineer may authorize minor variances from the Storm
Water Threat Assessment Criteria in special circumstances where it
can be shown that a lesser or higher Construction SWPPP Tier Level is
warranted.
Project Address:
Assessor Parcel No.
Owner/Owner's Authorized Agent Na e:
Title:
Owner/Owner's Authorized Agent Signatur :
Date:
7
City Concurrence:
IBy:e
Date:
Pro'
�
1/14 YES ❑ NO
V f V
4 i (
IC/�
B-24 Page 1 of 1 Rev.03/09
CITY OF
CARLSBAD
CONSTRUCTION THREAT
ASSESSMENT WORKSHEET FOR
DETERMINATION OF PROJECT'S
PERCEIVED THREAT TO
STORM WATER QUALITY
E-33
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
Construction
Perceived
SWPPP Tier
Construction Threat Assessment Criteria*
Threat to
Level
Storm Water
Qualitv
Tier 3 — Hioh Construction Threat Assessment Criteria
❑ ' Project site is 50 acres or more and grading will occur during the rainy season
❑ Project site is 1 acre or more in size and is located within the Buena Vista or Agua Hedionda
Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or
discharges directly to an ESA
❑ Soil at site is moderately to highly erosive (defined as having a predominance of soils with
High
Tier 3
USDA-NRCS Erosion factors kf greater than or equal to 0.4)
❑ Site slope is 5 to 1 or steeper
❑ Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1
through April 30).
❑ Owner/contractor received a Storm Water Notice of Violation within past two years
Tier 3 — Medium Construction Threat Assessment Criteria
❑ All projects not meeting Tier 3 High Construction Threat Assessment Criteria
Medium
Tier 2 High Construction Threat Assessment Criteria
❑ Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or
within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA
❑ Soil at site is moderately to highly erosive (defined as having a predominance of soils with
USDA-NRCS Erosion factors kf greater than or equal to 0.4)
High
Tier 2
❑ Site slope is 5 to 1 or steeper
❑
Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1
through April 30).
❑ Owner/contractor received a Storm Water Notice of Violation within past two years
❑ Site results in one half acre or more of soil disturbance
Tier 2 — Medium Construction Threat Assessment Criteria
❑ All projects not meeting Tier 2 High Construction Threat Assessment Criteria
Medium
Tier 1 - Medium inspection Threat Assessment Criteria
❑ Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, within or
directly adjacent to an environmentally sensitive area (ESA) or discharges directly to an ESA
❑. Soil at site is moderately to highly erosive (defined as having a predominance of soils with
USDA-NRCS Erosion factors kf greater than or equal to 0.4)
❑ Site slope is 5 to 1 or steeper
Medium
Tier 1
❑ Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1
through April 30).
❑ Owner/contractor received a Storm Water Notice of Violation within past two years
❑ Site results in one half acre or more of soil disturbance
Tier 1 - Low Inspection Threat Assessment CriteriaAll
projects not meeting Tier 1 Medium Construction Threat Assessment Criteria
W
Exempt
- Not Applicable -
Exempt
UILY cnyu IUar May aln"01 ice rumor variances rrom the construction threat assessment criteria in special circumstances
where it can be shown that a lesser or higher amount of storm water compliance inspection is warranted in the opinion of
the city engineer
E-33 Page 1 of 1 REV 4/30/10
V CITY OF
rRALSDAD
STORM WATER
STANDARDS
QUESTIONNAIRE
E-34
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
To address post -development pollutants that may be generated from development projects, the City requires that new development and
significant redevelopment priority projects incorporate Permanent Storm Water Best Management Practices (BMP's) into the project
design per the City's Standard Urban Stormwater Management Plan (SUSMP). To view the SUSMP, refer to the Engineering Standards
(Volume 4, Chapter 2) at www.carisbadca.gov/standards.
Initially this questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision,
discretionary permits and/or construction permits). The results of the questionnaire determine the level of storm water standards that
must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to
'Standard Stormwater Requirements' or be subject to additional criteria called 'Priority Development Project Requirements'. Many
aspects of project site design are dependent upon the storm water standards applied to a project.
Your responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has
responsibility for making the final assessment after submission of the development application. If staff determines that the questionnaire
was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by you, this will result in the return
of the development application as incomplete. In this case, please make the changes to the questionnaire and resubmit to the City.
If you are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, please
seek assistance from Land Development Engineering staff.
A separate completed and signed questionnaire must be submitted for each new development application submission. Only one
completed and signed questionnaire is required when multiple development applications for the same project are submitted concurrently.
In addition to this questionnaire, you must also complete, sign and submit a Project Threat Assessment Form with construction permits
for the project.
Please start by completing Step 1 and follow the instructions. When completed, sign the form at the end and submit this with your
application to the city.
To determine if your project is a priority development project, please answer the following questions:
YES NO
1. Is your project LIMITED TO constructing new or retrofitting paved sidewalks, bicycle lanes or trails that meet
the following criteria: (1) Designed and constructed to direct storm water runoff to adjacent vegetated areas, or
other non -erodible permeable areas; OR (2) designed and constructed to be hydraulically disconnected from /
paved streets or roads; OR (3) designed and constructed with permeable pavements or surfaces in V
accordance with USEPA Green Streetsguidance?
2. Is your project LIMITED TO retrofitting or redeveloping existing paved alleys, streets, or roads that are
designed and constructed in accordance with the USEPA Green Streets guidance? !�
If you answered "yes" to one or more of the above questions, then your project is NOT a priority development project and therefore is
NOT subject to the storm water criteria required for priority development projects. Go to step 4, mark the last box stating "my
project does not meet PDP requirements" and complete applicant information.
If you answered "no" to both questions, then go to Step 2.
E-34 Page 1 of 3 Effective 6/27/13
CITY OF
ARLSDA
STORM WATER
STANDARDS
QUESTIONNAIRE
E-34
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
�v i
Olt A-1
mi,
e,•t•
To determine if your project is a priority development project, please answer the following questions:
YES NO
1. Is your project a new development that creates 10,000 square feet or more of impervious surfaces collectively
over the entire project site? This includes commercial, industrial, residential, mixed -use, and public
development projects on public or private land.
2. Is your project creating or replacing 5,000 square feet or more of impervious surface collectively over the entire
project site on an existing site of 10,000 square feet or more of impervious surface? This includes commercial,
✓
industrial, residential, mixed -use, and public development pro ects on ublic or rivate land.
3. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface
collectively over the entire project site and supports a restaurant? A restaurant is a facility that sells prepared
foods and drinks for consumption, including lunch
/
stationary counters and refreshment stands selling prepared
t/
foods and drinks for immediate consumption.
4. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface
collectively over the entire project site and supports a hillside development project? A hillside development
project includes development on any natural slope that is twenty-five percent or greater.
5. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface
collectively over the entire project site and supports a parking lot. A parking lot is a land area or facility for the
temporary parking or storage of motor vehicles used personally for business or for commerce.
6. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface
collectively over the entire project site and supports a street, road, highway freeway or driveway? A street,
road, highway, freeway or driveway is any paved impervious surface used for the transportation of
V
automobiles, trucks, motorcycles, and other vehicles.
7. Is your project a new or redevelopment project that creates or replaces 2,500 square feet or more of
impervious surface collectively over the entire site, and discharges directly to an Environmentally Sensitive
Area (ESA)? "Discharging Directly to" includes flow that is conveyed overland a distance of 200 feet or less
from the project to the ESA, or conveyed in a pipe or open channel any distance as an isolated flow from the
project to the ESA i.e. not commingles with flows from adjacent lands).*
8. Is your project a new development that supports an automotive repair shop? An automotive repair shop is a
facility that is categorized in any one of the following Standard Industrial Classification (SIC) codes: 5013,
5014, 5541, 7532-7534, or 7536-7539.
9. Is your project a new development that supports a retail gasoline outlet (RGO)? This category includes RGO's
that meet the following criteria: (a) 5,000 square feet or more or (b) a project Average Daily Traffic (ADT) of
100 or more vehicles per day.
10. Is your project a new or redevelopment project that results in the disturbance of one or more acres of land and
/
are expected to generate pollutants post construction?
11.Is your project located within 200 feet of the Pacific Ocean and (1) creates 2,500 square feet or more of
impervious surface or (2) increases impervious surface on the property by more than 10%?
If you answered "yes" to one or more of the above questions, you ARE a priority development project and are therefore subject to
implementing structural Best Management Practices (BMP's) in addition to implementing Standard Storm Water Requirements such
as source control and low impact development BMP's. A Storm Water Management Plan (SWMP) must be submitted with your
application(s) for development. Go to step 3 for redevelopment projects. For new projects, go to step 4 at the end of this
questionnaire, check the "my project meets PDP requirements" box and complete applicant information.
If you answered "no" to all of the above questions, you ARE NOT a priority development project and are therefore subject to
implementing only Standard Storm Water Requirements such as source control and low impact development BMP's required for all
development projects. A Storm Water Management Plan (SWMP) is not required with your application(s) for development. Go to step
4 at the end of this questionnaire, check the "my project does not meet PDP requirements" box and complete applicant
information.
E-34 Page 2 of 3 Effective 6/27/13
A 1
PLANNING DIVISION
PLANCHECK APPROVAL
P-28
DATE: 5/12/15 PROJECT NAME: ADDITION PROJECT ID:
PLAN CHECK NO: CB151126 SET#: ADDRESS: 1026 BEACON BAY DR
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.eov
Z This plan check review is complete and has been APPROVED by the
PLANNING Division.
By: GINA RUIZ
A Final Inspection by the PLANNING Division is required ❑ Yes ® No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to:
ROBERT@SOLANAVISTABUILDERS.COM
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING"
760-602-4610
ENGINEERING
760-602-2750
FIRE PREVENTION
760-602-4665
Chris Sexton
760-602-4624
Chris.Sexton@carisbadca.gov
Gina Ruiz
760-602-4675
Gina.Ruiz@carlsbadca.gov
r
REVIEW #:
1 2 3
0■ ■
■ /1 ■
Plan Check No. CB151126 Address 1026 BEACON BAY DR Date 5/12/15
Review # 2
Planner GINA RUIZ Phone (760) 602- 4675
Type of Project & Use: ADDITION
Zoning: P-C General Plan: RM Facilities Management Zone: 20
CFD (in/out) #_Date of participation: Remaining net dev acres:
(For non-residential development: Type of land use created by this permit: )
Legend: , ® Item Complete
Environmental Review Required:
DATE OF COMPLETION:
❑ Item Incomplete - Needs your action
YES ❑ NO ❑ TYPE:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES ❑ NO ® TYPE
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES M NO ❑
CA Coastal Commission Authority? YES ❑ NO M
If California Coastal Commission Authority: Contact them at — 7575 Metropolitan Drive,
Suite 103, San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt): ADDITION TO HOUSE FOLLOWS
WET BAR DEFINITION THEREFORE NOT DEFINED AS SDU — CONVERSION OF THIS
ADDITION TO A SECOND DWELLING UNIT WILL REQUIRE A COASTAL
DEVELOPMENT PERMIT AT THAT TIME
®❑ ❑ Habitat Management Plan
Data Entry Completed? YES ❑ NO
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application
and assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of
Habitat Type impacted/taken, UPDATE!)
®❑ ❑ Inclusionary Housing Fee required: YES ❑ NO
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
Data Entry Completed? YES ❑ NO ❑
(A/P/Ds, Activity Maintenance, enter CB#,
Housing Y/N, Enter Fee, UPDATE!)
®❑ ❑ Housing Tracking Form (form P-20) completed
toolbar, Screens, Housing Fees, Construct
YES ❑ NO ❑ N/A
P-28 Page 2 of 3 07/11
Y
Site Plan:
®❑❑
City Council Policy 44 — Neighborhood Architectural Design Guidelines
®❑ ❑ 1. Applicability: YES ❑ NO
®❑ ❑ 2. Project complies: YES ❑ NO❑
Zoning:
®❑ ❑
1. Setbacks:
Front:
Required 20'
Shown 24.4'
Interior Side:
Required 7.5'
Shown 7_6
Street Side:
Required N/A
Shown N/A
Rear:
Required 15'
Shown 43'
®❑ ❑
2. Accessory structure setbacks:
N/A
Front:
Required
Shown
Interior Side:
Required
Shown
Street Side:
Required
Shown
Rear:
Required
Shown
Structure separation:
Required
Shown
®❑ ❑
3. Lot Coverage:
Required 40% MAX Shown 25%
®❑ ❑ 4. Height: Required 24' (ROOF PITCH NOT STATES Shown 15'
®❑ ❑ 5. Parking: Spaces Required garage Shown garage
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required 1 Shown IN DRIVEWAY AS GARAGE IS SETBACK
24.4'
❑ ®❑ Additional Comments:
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER GINA RUIZ DATE 5/12/15
P-28 Page 3 of 3 07/11
PLUMBING,
ELECTRICAL,
MECHANICAL
WORKSHEET
8-18
=
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Building@carisbadca.gov
Project Address: Permit No.: 4 J511'C&
Information provided below refers to work being done on the above mentioned permit only.
This form must be completed and returned to the Building Division before the permit can be issued
Building Dept. Fax: (760) 602-8558
Number of new or relocated fixtures, traps, or floor drains ....................................................... -�
Newbuilding sewer line?......................................................................................... Yes No 6,'
Numberof new roof drains?...............................................................................................................
Install/alter water line?.........................................................................................................................
Numberof new water heaters?.........................................................................................................
Number of new, relocated or replaced gas outlets?....................................................................
Numberof new hose bibs?..................................................................................................................
Residential Permits:
New/expanded service: Number of new amps: jo
Minor Remodel only, Ves No X
Commercial/Industrial:
Tenant Improvement: Number of existing amps involvedin thisproiect
Number of new amps involvedin thisproiect:
New Construction: Amps per Panel:
SinglePhase............................................................... Number of new amperes
Three Phase................................................................. Number of new amperes
Three Phase 480........................................................ Number of new amperes
Number of new furnaces, A/C, or heat pumps?............................................................................ %
New or relocated duct worh?.......................................................................... Yes f No
Numberof new fireplaces?................................................................................................................. .e
Numberof new exhaust fans?............................................................................................................
Relocate/install vent?............................................................................................................................
Numberof new exhaust hoods?........................................................................................................
Number of new boilers or compressors?........................................................... Number of HP -�
B-18 Page 1 of 1 Rev. 03/09
ri
4� City of
Carlsbad
CERTIFICATION OF
SCHOOL FEES PAID
B-34
Development Services
Building Department
1635 Faraday Avenue
760-602-2719
www.carisbadca.gov
This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City
prior to issuing a building permit. The City will not issue any building permit without a completed school fee form.
Project Name HAMPTON ADDITION Project ID: CT/MS:
Building Permit
Plan Check Number: CB15-1126
Project Address: 1026 BEACON BAY DRIVE
A. P. N 214-530-10-00
Project Applicant
(Owner Name): ROBERT HAMPTON
Project Description: 498 SQ FT ADD AND CONVERT 22 SQ FT GARAGE TO HABITABLE
Building Type SFD
Residential: NEW DWELLING UNIT(S)
Square Feet of Living Area in New Dwelling/s
Second Dwelling Unit: Square Feet of Living Area in SDU
Residential Additions: 520 Net Square Feet New Area
Commercial/Industrial: Net Square Feet New Area
City Certification of
Applicant Information: dfn,4 9(togA
Date 05/01/2015
SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD
® Carlsbad Unified School District ❑ Vista Unified School District ❑ San Marcos Unified School District
6225 El Camino Real 1234 Arcadia Drive 2 5 5 P i c o Ave S t e. 1 0 0
Carlsbad CA 92009 (760-331-5000) Vista CA 92083 (760-726-2170) xt San Marcos, CA 92069 (760-290-2649)
2222 Contact: Nancy Dolce (By Appt. Only)
❑ Encinitas Union School District ❑ San Dieguito Union High School District -By Appointment Only
101 South Rancho Santa Fe Rd 684 Requeza Dr.
Encinitas, CA 92024 Encinitas, CA 92024
(760-944-4300 x1166) (760-753-6491 x 5514 )
Certification of Applicant/Owners. The person executing this declaration ("Owner') certifies under penalty of perjury
that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner
will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number
of dwelling units or square footage after the building permit is issued or if the initial determination of units or square
footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or
that the person executing this declaration is authorized to sign on behalf of the Owner.
Signature: d+✓�r z°' _ Date: (r�
4 s 7 Pav wi/n9
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school district(s))
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE
PROJECT HAVE BEEN OR WILL BE SATISFIED.
SCHOOL DISTRICT:
The undersigned, being duly authorized by the applicable School District, certifies that
the developer, builder, or owner has satisfied the obligation for school facilities. This is
to certify that the applicant listed on page 1 has paid all amounts or completed other
applicable school mitigation determined by the School District. The City may issue
building permits for this project.
SIGNATURE OF AUTHORIZED SCHOOL
DISTRICT OFFICIAL
r DZV:tea14il?'04--kc
TITLE
NAME OF SCHOOL DISTRICT CARLSBAD UNIFIED SCHOOL SM Et CAMINO REAL
----DATE ---- --- CARLSSAD, CA 92009
PHONE NUMBER
CC l= 0 #- 3
8-3-4 Page 2 of 2 Rev. 03109