Loading...
HomeMy WebLinkAbout1028 PINE AVE; ; CB012562; Permit\4i , City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 06-03-2002 Residential Permit Permit No: CB012562 Building Inspection Request Line (760) 602-2725 Job Address: 1028 PINE AV CBAD Permit Type: RESDNTL Sub Type: RAD Status: ISSUED Parcel No: 2041111900 Lot #: 0 Applied: 08/01/2001 Valuation: $74,469.00 Construction Type: NEW Entered By: JM Occupancy Group: Reference #: Plan Approved: 10/01/2001 # Dwelling Units: 0 Structure Type: Issued: 06/03/2002 Bedrooms: 0 Bathrooms: 0 Inspect Area: Project Title: DOKKEN - RAD 723 SF BDRM&BA Orig PC#: Plan Check#: Applicant: Owner: 8430 06/03/02 0002 01 02 RON LEWIS/REAL VALUE DOKKEN MARY T LIVING TRUST COP 209101 4135 LINDA VISTA DR 1022 PINE AVE FALLBROOK CA 92008 CARLSBAD CA 92008 760-730-9396 Total Fees: $2,383.71 Total Payments To Date: $292.70 Balance Du $2,091.01 Building Permit $450.31 Meter Size Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $292.70 Meter Fee $0.00 Add'I Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $7.45 PFF $0.00 Park in Lieu Fee $0.00 PFF (CFD Fund) $0.00 Park Fee $0.00 License Tax $0.00 LFM Fee $0.00 License Tax (CFD Fund) $0.00 Bridge Fee $0.00 Traffic Impact Fee $0.00 Other Bridge Fee $0.00 Traffic Impact (CFD Fund) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL . $63.00 Renewal Fee $0.00 ELECTRICAL TOTAL $20.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $26.00 Other Building Fee $0.00 Housing Impact Fee $0.00 Pot. Water Con. Fee $0.00 Housing InLieu Fee $0.00 Meter Size Master Drainage Fee $1,463.75 Add'I Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $60.50 TOTAL PERMIT FEES $2,383.71 FINAL,APPROV '~,~ lnsrecto/9/ Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any PERMIT 'APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 1. PROJECT INFO RMATQX FOR OFFICE USE ONJ4' PLAN CHECK N(L-/1 EST. VAL.( (,72I Plan Ck. Deptl_A Validated By _J4'( / Date <711 Address (include Bldg/Suite #) Business Name (at this address) f ( ? ' 6294 08,01 /OiN 002 taI # Qnits Legal Description Lot No, Subdivision Name/Number Unit No. f ase COP 2927O ASSSSO)arcel # Existing Use ' 'Fl .L.' 1- '• 1' "' Pose"UeI 3 # of Bathrooms 2 NTACT)SON (if different from aplica4l - " - L 'Vt-' V Rni LcA—L5 'ii'3 Ji)'P4 V1i TA- Pk , FLLi,-k q Name Address City State/Zip Telephone # Fax # 3 APPLICANT Contractor E Agent for Contractor Owner n Agent for Owner R eA ^I / J t t4 I Z L L , ,,)a4 illc~'11A_()A rAt afvi" A ?i Name Address City State/Zi 1'elPhone # 4 PROPERTY OWNER NA1 0 57 L-, CC Name '. Address City State/Zip Telephone # S CONTRACTOR COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to Construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exe ption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dq1jrs I$500]l. 44.7& 5? v7z97c Name , Address City State/Zip Telephone # State License # ' ? License Class IZ) City Business License # 5 (4C,7*- 1,24 frLLI4?cJ 9s°Z O.'17A4' Designer Name Address "- City State/Zip Telephone State License # 7' c,51/'6 6 WORKERS COMPENSATIO 11 N Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company..'A(CJ,4— j4jE,4C4i,&._) 1)._5 Policy NoM} 2,"-7 I '''Expiration Date_______________ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) C3 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California, WARNING: Failure to secure workers' compensatio erage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($ 00,000), in addition of compensation, d mages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE - DATE 7/7. Oy hereby affirm #11atl aaTn exemptfr Vec.ntractor's License Law for the following reason: 0 I, as owner of the property my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). XI, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Con actor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES -._!Y have not) signed an application for a building permit for the proposed work. I have cent r cted with the folIo ng person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address I phone number / contractors license number(: I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): ROPERTY OWNER ..'ATE 9 z_— COMPLETE THIS SECTION ~RI~Qe~WSID NLY Is the applicant or future building occupanc"required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FfNAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS 9. APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit, of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued bhe building Official under t visions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not com$enced within 180 days tro date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commced for a period of 0 (Section 106.4.4 U ' rm Building Code). APPLICANT'S SIGNATURE 'A - flATC OI _eno I File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 01/14/2003 Permit# CB012562 Inspector Assignment: SR Title: DOKKEN- RAD 723 SF BDRM&BA Description: Type: RESDNTL Sub Type: RAD Phone: 760 9614 Job Address: 1028 PINE AV Suite: Lot 0 Location: Inspect APPLICANT RON LEWIS/REAL VALUE Owner: DOKKEN MARY T LIVING TRUST Remarks: Total Time: Requested By: MARY Entered By: CHRISTINE CD Description Act, Comment 19 Final Structural 1t111' 29 Final Plumbing 39 Final Electrical 4- 49 Final Mechanical Associated PCRs/CVs Inspection History Date Description Act Insp Comments 08/09/2002 17 Interior Lath/Drywall AP SR 08/06/2002 14 Frame/Steel/Bolting/Welding CO SR NEEDS TO INSTALL TEMP GLAZING WIN 2FT OF A DOOR. ALL ELSE OK 08/06/2002 18 Exterior Lath/Drywall AP SR 08/01/2002 13 Shear Panels/HD's AP SR INTERIOR & EXTERIOR SHEAR OK 07/25/2002 13 Shear Panels/HD's CO SR NOT NAILED OFF AS PER PLAN 07/24/2002 13 Shear Panels/HD's CO SR PANELS NOT NAILED AS PER SHEAR SCHEDULE 07/24/2002 15 Roof/Reroof AP SR OK TO COVER 07/02/2002 11 Ftg/Foundation/Piers AP SR SEE NOTICE ON CARD RE-FOUNDATION DATED 7/2/02 06/28/2002 21 Underground/Under Floor AP PK SEE NOTES ON CARD RE FOUNDATION EsGil Corporation In Partnership with Government for Building Safety DATE: August 10, 2001 JURISDICTION: Carlsbad PLAN CHECK NO.: 01-2562 PROJECT ADDRESS: 1028 Pine St. SET:! El AP CANT IJ FILE PROJECT NAME: SFD Addition for Mary Dokken The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Li Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Abe Doliente Enclosures: Esgil Corporation E GA El MB LI EJ [1 PC 8/2/01 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 01-2562 August 10, 2001 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 01-2562 PREPARED BY: Abe Doliente DATE: August 10, 2001 BUILDING ADDRESS: 1028 Pine St. BUILDING OCCUPANCY: R-3/U-1 TYPE OF CONSTRUCTION: V-N BUILDING PORTION AREA 1 (Sq. Ft.)_J Valuation Multiplier Reg. Mod. VALUE ($) SFDAddn 723 74,467 Air Conditioning Fire Sprinklers TOTAL VALUE 74,467 Jurisdiction Code Icb IBY Ordinance Bldg. Permit Fee by Ordinance 'vj I $441.31 Plan Check Fee by Ordinance j I I $286.851 Type of Review: 2 Complete Review Structural Only El Other E) Repetitive Fee p Repeats 171 Hourly Hour * Esgil Plan Review Fee I $247.131 Comments: Sheet 1 of 1 macvalue.doc of Carlsbad BUILDING PLANCHECK CHECKLIST DATE: __ PLANCHECKNO.: CB O'i BUILDING ADDRESS: PROJECT DESCRIPTION: __AD ______________________________________ ASSESSOR'S PARCEL NUMBER: -fl - 1 g EST. VALUE: qg,g ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. E A Right-of-Way permit is required prior to construction of the following improvements: DENIAL Please see ,tte attached report of deficiencies marked wit) Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: Date: l~k UA~* 14 L0161 By: Date: By: Date: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: By: Date: ATTACHMENTS ENGINEERING DEPT. CONTACT PERSON El Dedication Application Name: TAN IYA WADE Dedication Checklist City of Carlsbad LI Improvement Application LI Improvement Checklist LI Future Improvement Agreement LI Grading Permit Application LI Grading Submittal Checklist 11 Right-of-Way Permit Application Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2773 CFD INFORMATION Parcel Map No: Lots: Recordation: [1 Right-of-Way Permit Submittal Checklist Carlsbad Tract: and Information Sheet LI Sewer Fee Information Sheet A-4 H\WORO\OH Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760),.602-8562 LSVBudding PIanc9'eck Cklst BP0001 Fomi JJ.doc 1 R V. 12/26/96 BUILDING PLANCHECK CHECKLIST SITE PLAN 1 S _-2ND 3RD 1. Provide a fully dimensioned site plan drawn to scale. Show: )—North Arrow 7eDriveway ight-of-Way Width & Adjacent Streets ,-Existing & Proposed Structures widths -Eisting Street Improvements L, Existing or proposed sewer lateral BProperty Lines V-, Existing or proposed water service E--1asements J/ Existing or proposed irrigation service E 2. Show on site plan: ," Drainage Patterns Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." .-T--Existing & Proposed Slopes and Topography ize, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. Jo--Sewer and water laterals should not be located within proposed driveways, per standards. E 3. Include on title sheet: Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION H:WORD\DOCS\CHKLSTBuiIding Plantheck Cklst Form (Ger,eric).doc 2 Rev. 7114/00 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3rd DISCRETIONARY APPROVAL COMPLIANCE 0 4a. Project does not comply with the following Engineering Conditions of approval for ProjectNo.________________________________________________________ 0 0 0 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS 0 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $15,000, pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 1/2" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS 0 0 0 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $75,000, pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the H:\WORD\DOCS\CHKLSTBudding Piancheck Cklst Form (RIDDLE - HARVEY 7-12-00).doc 3 Rev. 12/26/96 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and tees paid prior to issuance of building permit. Improvement Plans signed by: Date: U U U 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. I. U Future public improvements required as follows: U 6c. Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: U 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. . . U 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). U U U 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: U U U 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) H:\WORD\OOCS\CHKLSPBuiIding PIncheck Cklst Form (Generic 7-14-00).doc 4 Rev. 7/14/00 BUILDING PLANCHECK CHECKLIST• 1ST ND 3RD LILY 0 7d .No Grading Permit required. 0 0 0 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS U 0 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: \t114 U 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District .personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: iA U LIJ 10.NPDESPERM Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. U U 11. equired fees are attached :IV k3 0 No fees required WATER METER REVIEW U U 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. All single family dwelling units received "standard" 1" service with 5/8" service. H:\WORD\DOCS\CHKSTBuding Pntheck CkJst Form (Generlc).doc 5 Rev. 7114100 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3 R If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. Maximum service and meter size is a 2" service with a 2" meter. If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand. (manifolds are considered on case by case basis to limit multiple trenching into the street). 4jICj U U 12b. Irrigation Use (where recycled water is not available) 11 All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: .,-... STA 1+00 Install 2" service and 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (wl a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant musf provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: Hydraulic grade line Elevation at point of connection (POC) Pressure at POC in pounds per square inch (PSI) Worse case zone (largest, farthest away from valve Total Sprinkler heads listed (with gpm use per head) Include a 10% residual pressure at point of connection 3. In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water H:WORD\DOCS\CHKLSTBuilding Plantheck Ckls* Form (Genenc).dOc 6 Rev. 7114/00 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. U U 12c. Irrigation Use (where recycled water is available) Recycled water meters are sized the same as the irrigation meter above. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. 13. Additional Comments: wd * c'Q9- S. Tc, CA cq141cf S-k av4 Qc-u), flfri- \2. døM. (Afl14 ?1afl4, cmii ac'e (' aes) WcCAtO? H:\WORD'OOCS\CHKLST'Buitding Plancfledc Cklst Form (Geneslc).doC 7 Rev. 7114100 PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB 0 / Address Planner /&3 f 74'4_ Phone (760) 602- APN: OtI -•/fl• I', Type of P oject & Use:_________ Zoning: General Plan: Use: U >5 I (For non-residential development: Type of land used created by T. 5•5 0 2 U 2 __________________________________________________ this permit: NI - S - a. Legend: Item Complete Item Incomplete - Needs your actin Eq F~ F~ Eniironmental Review Reuired: YES NO TYPE - DATE OF COMPLETIONf______________ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: 1EJ • Discretionary Action Required: YES NO TYPE 5, ) .5• \\ •'-: - APROVAL/RESO. NO.', DATE PROJECT NO. OTHER 4 RELATED CASES:______________________________________ Compliance with conditions,or approval? If not, state conditions which require action. Conditions of Approval:______________________________________________ Li _ _ _NO_ CA .Coastal Commission Authority? YES___ NO___ IT calilornia Coastal Commission Authority: Contact them at - 3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form, akeady completed? YES____ NO I NO complete Coastal Permit Detrrnination orm*ów. Coastal Permit Determinatioj- -5 '_•5 I_S -5 - 4 - (•_•I •) -,_• ) Follow-Up Actions: 1) Stamp BuiIdingPlansas "Exempt" r "CQastal Perth,t Required" Floor1Plans). i.... U_••• •,;•r•--. - ' c Co. mpIke Coastal Permit Determination Ld as needed - 1H\ADMIN\COUNTER\BldgPlnchkRevChkist • • , ' -• -• • . • .5_S -' - • -c •. ., • • ,-: - • • - - - • :':- f- L . I - .5 U (at minimum Project Density: DU/AC Facilities Management Zone: 1*141. CFD flnIriiit' # Date of participation: Remaining net dev acres: Circle One Coastal Zone AssesshientiCompliance Project site located in Coastal Zone? YES ____ Inclusionary Housing Fee required: YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993,) ,Data Enty,Cothpleted? YES -NO (A'/P/Ds, Activity Maintnance, enter CB#, toolbar, Sceens, HousingFees, Construct Housing YIN, Enter Fee, UPDATEUY c:), -' ,•' ., - ... F Site Plan: Provide a fully dimensionat ie Ié'n drawn to scale. Show: North arrow, property lines, easemerts --xisting and proposed structures, streets, existing Street improvements, rightof-way width, dimensional setbacks and ,.exksting>-' topographical lines. Provide legal description of property and assessor's parcel number. Zoning: -I 1"J, X~kol.~~ A*-4 1 Setbacks: Front: Required 20 Shown Interior Side: Required ' Shown 5 " Street Side: Required " Shown Rear: Required Shown 2. Accessory structure setbacks: Front: Required c) Shown Interior Side: Required Shown 3 Street Side: Required Shown Rear: Required —/'7, Shown 7/' Structure separation: Required Shown 7-42' Lot Coverage: Required - (-' ( Shown [R F-1 E 4. Height: Required Shown 5. Parking: Spaces Required '2— Shown Guest Spaces Required ....- Shown Additional ( I-] L /1 L'A". /Q '- t -" (.L/lV 1/c," qo-T-f 4Q OK TO ISSUE A$'JD4ETERED APPROVAL INTO COMPUTER H:\ADMIN\COUNTER\BldgPlnchkRevChklst / (jOC/'0 — "7 -p t.c2( DATE__ I Number of New Dwelling Units Square Feet of Living Area in New Dwelling Square Feet of Living Area in SDU Net Scivare Feet New Area C Ii of Carlsbad PAYMENT OF SCHOOL FEES OR OTHER MITIGATION This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit. The City will not issue any building permit without a completed school fee form. Project Name: Building Permit Plan Check Number: Project Address: A.P.N.: Project Applicant (Owner Name(s): Project Description: BUILDING TYPE: Residential: Second Dwelling Unit: Residential Additions: Commercial/Industrial: City Certification of applicant's information: SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD Cadsbd Unified School San Marcos Unified School District 801 Pine Ave. 215 Mata Way Carlsbad CA 92009 (72c San Marcos, CA 92069 (290-2649) Encinitas Union Shool Diltrict San Dieguito Union High School District 101 South Rancho Santa Fe Rd 710 Encinitas Blvd. Encinitas, CA 92024 (9444300) Encinitas, CA 92024 (753-6491) Certification of Applicant/Owners. The person executing this declaration ("Owner") certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect, and that (2) the Owner is the owner/ developer of the above described project(s), or that the person executing this declaration is authorized to sign on behalf of the Owner. Signature: Date: SCFOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school district(s)) 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2700 • FAX (760) 602-8560 Rp,irI 411 7lflfl 4 *************************************************************************************************** THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. SCHOOL DISTRICT: The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District. The City may issue building permits for this project. SIGNATURE OF AUTHORIZED SCHOOL DISTRICT OFFICIAL TITLE NAME OF SCHOOL DISTRICT DATE PHONE NUMBER 74/ Gaytfb Freman Assistant Superintendent Business Services 7•- Rp,ir1 4117/flfl